Kerala State Housing Board Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Kerala State Housing Board - KSHB Tender
Eprocure
Opening Date18 Sep 2021
Closing Date28 Sep 2021
Tender Amount₹ 22,03,809
Costs
EMD
₹ 33,100Document Cost
₹ 2,400Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_KSHB_440465_1Bid Award Id
ViewTender No
2021_THU_KSHB_1Tender Authority
Kerala State Housing Board ViewPurchaser Address
-Website
http://http://www.kshb.kerala.gov.in/kshb/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
od139869/2021_2022 : Supply and wiring points according to IS 732-1989 using rigid PVC ivory conduit of minimum size 20 mm conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.5 sq mm FRLS PVC insulated stranded single core FR copper conductor cable 650V grade,including providing switch board main ,and continuous earthing with 1.5sqmm green coloured FRLS PVC insulated wire , required qty of copper earth socket, brass bolt and nut crimping etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6 A modular type ROHS compliant SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required (RoHS compliant modular accessories)..<br>Twin Control light point with 6A, plate ceiling rose - Short point
3
-
-
od139871/2021_2022 : Supply and wiring points according to IS 732-1989 using rigid PVC ivory conduit of minimum size 20 mm conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.5 sq mm FRLS PVC insulated stranded single core FR copper conductor cable 650V grade,including providing switch board main ,and continuous earthing with 1.5sqmm green coloured FRLS PVC insulated wire , required qty of copper earth socket, brass bolt and nut crimping etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6 A modular type ROHS compliant SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required (RoHS compliant modular accessories)..<br>Single Control light point with 6A, plate ceiling rose - Short point
55
-
-
od139873/2021_2022 : Supply and wiring points according to IS 732-1989 using rigid PVC ivory conduit of minimum size 20 mm conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.5 sq mm FRLS PVC insulated stranded single core FR copper conductor cable 650V grade,including providing switch board main ,and continuous earthing with 1.5sqmm green coloured FRLS PVC insulated wire , required qty of copper earth socket, brass bolt and nut crimping etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6 A modular type ROHS compliant SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required (RoHS compliant modular accessories).<br>Single control ceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator. - Short point
24
-
-
od139876/2021_2022 : Supply and wiring points according to IS 732-1989 using rigid PVC ivory conduit of minimum size 20 mm conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.5 sq mm FRLS PVC insulated stranded single core FR copper conductor cable 650V grade,including providing switch board main ,and continuous earthing with 1.5sqmm green coloured FRLS PVC insulated wire , required qty of copper earth socket, brass bolt and nut crimping etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6 A modular type ROHS compliant SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required.<br>Independent plug <br>Group A
20
-
-
90.1.1.1 : Supply and laying medium gauge PVC conduit of the following sizes conforming to IS 9537/1983 Part III in roof slab, jointing the pipes with PVC solvent cement, tying & fixing the conduit firmly with the re-inforcement etc. as required.20 mm
60
-
-
90.1.1.2 : Supply and laying medium gauge PVC conduit of the following sizes conforming to IS 9537/1983 Part III in roof slab, jointing the pipes with PVC solvent cement, tying & fixing the conduit firmly with the re-inforcement etc. as required.25 mm
100
-
-
90.1.1.3 : Supply and laying medium gauge PVC conduit of the following sizes conforming to IS 9537/1983 Part III in roof slab, jointing the pipes with PVC solvent cement, tying & fixing the conduit firmly with the re-inforcement etc. as required.32 mm
50
-
-
SUB MAIN WIRING
-
-
-
1.17.3 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
200
-
-
1.17.6 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm
30
-
-
1.17.12 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
200
-
-
1.17.21 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
400
-
-
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
500
-
-
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
500
-
-
1.17.30 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm
750
-
-
FIXING LED TUBE ,SURFACE PANEL,BULB,BULK HEAD
-
-
-
90.3.19.3 : Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required1200 mm 1X20W LED Lamp with box type fixture
26
-
-
od139866/2021_2022 : Supply, conveyance, installation, testing and commissioning of pre-wired light fittings made of .5mm thick CRCA sheet accessories and commissioning of Surface Panel type LED Round /Square Fittings9-12 Watts ,not less than 1500lm lumen and giving connection with 3 core round flex wire .etc .complete.<br>
10
-
-
od139870/2021_2022 : Supply, conveyance, installation, testing and commissioning of pre-wired light fittings made of .5mm thick CRCA sheet accessories and commissioning of Surface Panel type LED Round /Square Fittings18Watts(Dimension:300mmX40mm) not less than 2500lm lumen and giving connection with 3 core round flex wire .etc .complete.
10
-
-
od139874/2021_2022 : Supply, conveyance installation testing and commissioning of pre-wired light 8W to 10Ws LED ordinary type LED light fittings complete with all accessories and lamps etc. directly on wall or ceiling with PVCround block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.
6
-
-
od139875/2021_2022 : Supply and fixing cast aluminium stove enameled bulk head fittings with deep drawn anodised aluminium body, epoxy powder coated, heat resistant prismatic glass cover suitable for 9W LED to wall / ceiling including giving connections with required length of 6/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and making good the srface asrequired
5
-
-
FIXING CELLING,EXHAUST,WALL FAN
-
-
-
90.4.1 : Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
24
-
-
90.4.8 : Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.
7
-
-
od139872/2021_2022 : Supply, conveyance, installation, testing and commissioning of the 305 mm exhaust fans in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of 24/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS,305 mm, single phase, heavy duty, 1400 rpm exhaust fan in metal frame<br>
7
-
-
SP DB
-
-
-
2.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
21
-
-
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
168
-
-
2.12.2 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
21
-
-
2.14.3 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
21
-
-
3P DB
-
-
-
2.13.2 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
1
-
-
2.15.3 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
1
-
-
90.11.1.10 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)
1
-
-
15A PLUG ,SOCKET
-
-
-
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
20
-
-
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
20
-
-
1.27.2 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
20
-
-
MV CABLE LAYING
-
-
-
90.12.6.42 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.4 core 25 sq mm
10
-
-
90.12.7.42 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp
65
-
-
90.12.5.29 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 50 sq mm
20
-
-
90.12.6.29 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 50 sq mm
50
-
-
90.12.7.29 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 50 sq mm with factory made clamp
50
-
-
CABLE BARE EARTHING,EARTH CLAMPS,EARTH SCOKET
-
-
-
9.1.34 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)
4
-
-
9.1.22 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)
4
-
-
90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
200
-
-
90.16.5.3 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
6
-
-
PLATE EARTHING
-
-
-
5.4 : Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and
providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
6
-
-
5.8 : Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth
electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required.
(Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
30
-
-
5.9 : Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth
electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
10
-
-
5.14 : Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
20
-
-
5.15 : Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
30
-
-
ELECTRIC METTER BORD, KSEB CONNECTION
-
-
-
od139865/2021_2022 : Supply and fixing single phase meter board consisting of 63A cut out, neutral link &double pole isolator, with enclosure the cost not included KSEB meter including all connection etc .complete<br>
18
-
-
od140132/2021_2022 : Provision for giving electric connection from KSEB to main panel board theamount inclusive of installation of concrete poles supplied by KSEB .the wholeamount reimerse to the contractor against original cash receipt
1
-
-
od140133/2021_2022 : Supply and fixing the Single phase KWH meter, 240 V, 10 ? 40 A ,electronic type energy meter ? accuracy class 1
18
-
-
od205828/2020_2021 Provision for statuary fee at KSEB Limited (single phase) for effecting Electric connection original amount will be reimbursed after submitting original receipt (External Electrification not included in this item)
18
-
-
VDB
-
-
-
90.11.1.18 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)
1
-
-
90.14.10.3 : Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 16 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
1
-
-
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
4
-
-
GENETOR
-
-
-
od139995/2021_2022 : Supply,Installation,testing and commissioning of 40KW DG Set with Standard Control panel ,CPCB II Type approved Accoustic Enclosure and Anti Vibration pads asper CPCB norms comprising of radiator cooled ,Turbocharged after cooled diesel engine with individual cylinder heads, developing 78BHPor moreat 1500RPM complete with standard accessories coupled to Alternator rated at 40KW at415Volt mounted on base frame with inbuilt fuel tank of 150 litres capacity, Standard RunningControl Panel and batteries with lead and AVM Pads etc as per Electrical Inspectorate requirements including unloading charges and all duties and taxes and including cost of extending the exhaust pipe uptothe DG set building by using B Class MS Pipe of suitable size formation of foundation and installation including providing emergency button
1
-
-
MSB
-
-
-
od140002/2021_2022 : Fabrication, supply, conveyance, installation testing and commissioning floor mounting, dust and verminproof, cubicle type LV panel board comprising of the following components/ devices & complying to IS8623.<br> Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly using 1.6mm CRCA sheet as per approved design and requirement 2mm for frame , with front access facility, busbar chambers with aluminium bus , hinged doors for all switch gear compartments and earthing the doorsusing braided copper conductor and providing indication lamps, digital type Multi function meter suitableCTs, danger notice board etc The board should be powder coating the assembly after subjecting to 7tank process as required. 2 Nos Copper earth bar of size 25 mm x 3 mm at the rear with 2 No. earth stud.Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The cubical panelboard shall have 9 Nos compartments of size not less than 300 mm x 600 mm and viewing glass for alloutgoing compartment doors of suitable size but not less than 100 mm x 100 mmx 3 mm includingproviding interconnection between all the switch gears with 6 Sqmm PVC insulated copper conductorcable. The panel Board should be fitted on the base frame for panel board using channels of classdesignation 75 including cutting,welding, drilling holes,painting two coats of synthatic enamel paint over acoat of zinc chromate paint botling the frame to the panel and to the furnished floor using required boltsand nuts making good the dameges colour washing and fixing the following switch gears etc as required.( Note: All the doors should have facility for sealing by KSEB Incomer-1 - EB<br>MCCB 200A FP 36KAMP BASED PROTECTION -2NOS<br>Instruments<br>*6A, C curve SP MCB - 1 set<br>*RYB indicationlamp, LED type - 1 set<br>*On, Off, Trip indication lamp, LED type - 1 set<br>*1set 3 phase Digital Multifunction meter with RS485 communication port EM6400NG or eql<br>*100/5A 15VA class 1 resin castCT - 1 set<br>*REF and standby Earth fault relay - 1set3 Phase, 4 wire, CT operated, 240 V, 5-10 A ,electronic type energy meter ? accuracy class 1 -1Set <br>incomer- DG<br>MCCB 125A TP 50KA MPBASED OC,SC PROTECTION - 1 NO<br>Nuetral contactor 160A & 95A TP AC3<br>Instruments<br>*6A, C curve SP MCB - 2 set<br>*RYB indication lamp, LED type - 2 set<br>*On,Off, Trip indication lamp, LED type - 2 set<br>*2set 3 phase Digital Multi function meter with RS485communication port EM6400NG or eql<br>*630/5A 15VA class 1 resin cast CT - 1 set,*400/5A 15VAclass 1 resin cast CT - 1 set<br>*standby Earth fault relay - 2set<br>AMF andSynch<br>Synchronization and Auto Load sharing of DG set using AGC200 series DEIF make controllerand accessories with battery charger - 1set<br>AMF using CGC400 series DEIF make controller andaccessories with battery charger - 1set<br>Outgoing.<br>*125A, TPN, 36kA, MCCB with thermalmagnetic release for adjustable OL & SC protection - 1no.<br>*63A, TPN, 36kA, MCCB with thermalmagnetic release for adjustable OL & SC protection -4no.<br>All the outgoing MCCB's with Spreader andROH<br>BUS BAR : suitable rating of Aluminum bus bar as per type test
1
-
-
SOLAR ON GRID
-
-
-
od139984/2021_2022 : Supply, Installation, Testing and commissioning of on grid solar photovoltaic Power Plant , Conforming to MNRE Specification as amended, consisting of Mono/Poly crystalline silicon solar cell, Net metering facility, necessary protections , earthing mounted on Aluminium /GI Structure of suitable strength with following components complete as required.<br>a)Solar photovoltaic module of capacity 330 wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part -2, Solar photovoltaic Module conversion efficiency shall not be less than 16.5%, PV Modules used in solar power plants /systems must be warranted for their out put peak watt capacity, which should not be less than 90% at the end of 10 years and 80 % at the end of 25 years.<br>b)Power conditioning unit (PCU) of 350-800 V DC input voltage range and 400 V AC, three phase 4 wire , 50 hz +/- 2.5hz, out put voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the grid voltage frequency.<br>c)Data monitoring system complete with all accessories.<br>d)Fixing of array junction box & main junction box with IP 65 Protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc as required <br>f) connection and interconnection by supplying & fixing required size XLPE insulated copper conductor 1.1 KV grade armoured power and control cable between solar modules, main power cable to grid supply PCU Unit along with supplying & fixing of necessary channel / conduit lugs and other accessories etc as required .( RATE FOR 1 kWp ) COST/kWp
5
-
-
WATER PUMP
-
-
-
od140001/2021_2022 : Supply, installation, testing and commissioning of jockey pump of inline vertical pump of 5HP,180 LPM 50m head, mechanical seals, stainless steel shaft high efficiency volute type with stainless steel casing,stainless steel impeller, pump connected with cross coupled to a squirrel cage induction motor totally<br>enclosed fan cooled (TEFC) type of suitable HP, with a supply condition of 415V, 3 phase, 50 Hz,including installation of all accessories as per<br>the functional requirements of OEM.