Kerala State Housing Board Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Kerala State Housing Board - KSHB Tender
Electrical and Electronics
Eprocure
Opening Date14 Mar 2024
Closing Date22 Mar 2024
Tender Amount₹ 32,63,305
Costs
EMD
₹ 50,000Document Cost
₹ 3,100Tender Fee
Refer Documents
Summary
Kshb-thu-construction Of P T Chacko Nagar Commercial Complex Medical College-electrical Works
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_KSHB_669691_1Bid Award Id
ViewTender No
2024_RE_KSHB-THU_01(Ele)Tender Authority
Kerala State Housing Board ViewPurchaser Address
-Website
http://http://www.kshb.kerala.gov.in/kshb/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
1.11 : Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
10
-
-
1.25 : Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
45
-
-
1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in
recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps
modular switch, connection etc. as required. (For light plugs to be used in non residential
buildings).
65
-
-
1.33 : Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block
including connection etc as required.
185
-
-
1.55.1 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group A
30
-
-
1.58 : Supplying and fixing PVC batten/ angle holder including connection etc. as required.
16
-
-
SUB MAIN WIRING
-
-
-
1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
500
-
-
1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
200
-
-
1.14.3 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
50
-
-
1.14.9 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 6 sq. mm + 2 X 6 sq. mm earth wire
150
-
-
1.17.33 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 6 sq. mm
20
-
-
1.17.3 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
200
-
-
1.17.6 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm
100
-
-
1.17.9 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.9 x 1.5 sq. mm
50
-
-
1.17.12 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
100
-
-
1.17.15 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 2.5 sq. mm
100
-
-
1.17.21 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
50
-
-
1.17.30 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm
200
-
-
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
300
-
-
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
100
-
-
1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
300
-
-
90.1.1.2 : Supply and laying medium gauge PVC conduit of the following sizes conforming to IS 9537/1983 Part III in roof slab, jointing the pipes with PVC solvent cement, tying & fixing the conduit firmly with the re-inforcement etc. as required.25 mm
100
-
-
90.1.1.3 : Supply and laying medium gauge PVC conduit of the following sizes conforming to IS 9537/1983 Part III in roof slab, jointing the pipes with PVC solvent cement, tying & fixing the conduit firmly with the re-inforcement etc. as required.32 mm
100
-
-
FIXING LED TUBE ,SURFACE PANEL,BULB,BULK HEAD
-
-
-
od170020/2021_2022 : Supply,providing,testing and commissioning of 7W to 9 W PWD Approved make LED Bulb<br>
16
-
-
od170173/2021_2022 : Supply conveyance, installation, testing and commissioning the light fittings of following types made with White powder coated/pre coated finish, CRCA channel for single for 1200 mm 18W/20W LED tube having IP20 , 6500K, 20W LED T8 - 2000 lumens, Aluminum housing with PC diffuser, THD<20%, Surge - 2kV, CRI-80, 50000 burning hours, single sided connection,. Multistage Isolated Constant Current Operated driver with range 110-265V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard. all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required<br>1200 mm 1X20W Aluminum housing with PC diffuser LED Tube with box type fixture
25
-
-
od263613/2022_2023 : Supply, conveyance, installation, testing and commissioning of Slim panel Surface mounted down lighter with all accessories, housing made up of die cast aluminium for better heat management. Hight Transmittivity Diffuser for better light output and uniform light distribution without glare. Driver and accessories are pre wired for easy installation and long service. CRI>70, Color temperature>6000K, IP20, Ambient temp-0 to 45DegC, Driver efficiency>85%, THD<20%, Powerfactor>0.95, Surge protection 2KV, Multistage Isolated Constant Current operated driver with range 150-270V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard.Square Slim surface mounted, Wattage 15-18W, similar to Wipro ,crompton,or Equivalent with luminaire lumen ≥ 2000 lm and giving connection with 3 core round flex wire .etc .complete.<br>
42
-
-
od234760/2019_2020 : Supply and fixing cast aluminium stove enameled bulk head fittings with deep drawn anodised aluminium body, epoxy powder coated, heat resistant prismatic glass cover suitable for 9W LED to wall / ceiling including giving connections with required length of 6/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and making good the srface asrequired
10
-
-
od261972/2022_2023 : Supply, conveyance, installation, testing and commissioning of Recess mounted circular /squre LED downlighter with housing made up of white powder coated, pressure die cast aluminium for better heat management. Hight Transmittivity Polycarbonate diffuser for uniform light distribution, white rim moulded in engineering plastic, driver pre wired upto terminal block, CRI>80, LED efficacy>170lm/W, LED Make:Nichia/Cree/Osram/etc , Color temperature-6500K, IP20, 50000 burning hours as per L70 Criteria, Ambient temp-0 to 50DegC, Driver efficiency>85%, THD<10%, Powerfactor>0.95, Surge protection in CM-2KV, Multistage Isolated Constant Current - Constant Voltage operated driver with range 150-270V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard.Circular recess mounted/squrerecess mounted,Wattage ≤ 15-18W recess mounted similar to make Wipro,crompton,jaguar,Philipser,etc. with luminaire lumen ≥ 820lm and System Efficacy ≥ 75lm/W.and including charges for cutting holes & frame for Gypsum/POP ceiling and.giving connection with 3 core round flex wire etc complete.<br>
30
-
-
od261125/2019_2020 : Supply, conveyance installation testing and commissioning of pre-wired 30W LEDStreet light fitting complete with all accessories and lamps,GI pipe etc and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.,30W LED street light fittings.<br>
3
-
-
od312725/2023_2024 : Supply, conveyance, installation, testing and commissioning of High efficient Floodlight,with all accessories Integral cradle mount LED luminaire with Aluminium pressure Die cast housing parts for long life,Seconday Polycarbonate lens for superior performance, Toughened glass with silicon gaskets for IP66 protection, Complete assembly with LED,IP67 potted Driver With Over temperature protection and Short circuit and Reverse Polarity Protection , Multistage Isolated Constant Current- Constant Voltage Operated driver with range 120-300V AC having Auto Cutoff at Low and High Voltage and auto recovery, Complaint to Safety Extra Low Voltage Safe level<60V DC as per IEC standard. Withstands 440 V for 8 Hrs, Driver efficiency>85%, Power factor>0.95, THD<10%, LED with CRI >70,Temperature range- 0 to 45DegC,with inbuilt SPD 10kv , Colour Temperature- 5700K, Surge protection in CM-4KV, 50000 burning hours as per L70 Criteria,LED Floodlight, Wattage ≤100W similar to WIPRO ,CROMPTON,JAQUAR OR Equivalent with luminaire lumen ≥ 10000lm and System Efficacy ≥ 100lm/W.
2
-
-
FIXING CEILING,EXHAUST,WALL FAN
-
-
-
90.4.1 : Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
45
-
-
90.4.8 : Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.
13
-
-
od276255/2021_2022 : Supply, Installation, Testing and Commissioning of 1200mm sweep, BEE -5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 no’s .blades, 30 cm long down rod, 2 no’s Canopies, shackle kit, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 9.17, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%,(Working in remote or electronic regulator), unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthling etc. complete as required
2
-
-
od261884/2022_2023 : Supply, conveyance, installation, testing and commissioning of the 225mm exhaust fans in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of 24/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS,225mm metal frame.
11
-
-
od234750/2019_2020 : Supply, conveyance, installation, testing and commissioning of the 305 mm exhaust fans in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of 24/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS,305 mm, single phase, heavy duty, 1400 rpm exhaust fan in metal frame<br>
2
-
-
SP DB,3P DB,VDB
-
-
-
2.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
12
-
-
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
208
-
-
2.4.1 : Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4 + 12), Double door
2
-
-
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
12
-
-
od261773/2022_2023 : Supplying and fixing 32 amps to 63 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.<br>Triple pole
10
-
-
2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
15
-
-
2.3.1 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator6 way, Double door
2
-
-
2.4.4 : Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4+12), Double door
1
-
-
90.11.1.15 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
2
-
-
90.11.1.19 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8 + 18) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)
2
-
-
90.14.10.3 : Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 16 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
2
-
-
2.12.1 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
13
-
-
2.13.1 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2
-
-
2.13.3 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.100 amps
2
-
-
2.14.2 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
13
-
-
2.15.2 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2
-
-
MV CABLE LAYING &CABLE TRAY
-
-
-
90.12.5.29 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 50 sq mm
20
-
-
90.12.6.29 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 50 sq mm
20
-
-
90.12.7.29 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 50 sq mm with factory made clamp
25
-
-
od263185/2022_2023 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.<br>2 core 2.5 sq mm with factory made clamp
30
-
-
90.12.5.30 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 70 sq mm
20
-
-
90.12.6.30 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 70 sq mm
8
-
-
90.12.7.30 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 70 sq mm
20
-
-
90.12.10.4 : Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation77/63 mm or nearest size
20
-
-
90.12.5.27 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 25 sq mm
15
-
-
90.12.6.27 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 25 sq mm
25
-
-
90.12.7.27 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 25 sq mm with factory made clamp
90
-
-
od263645/2022_2023 : Supply & laying of one number PVC insulated and PVC sheathed armoured copper power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 2.5 sq mm
20
-
-
od263653/2022_2023 : Supply & laying of one No. PVC insulated and PVC sheathed armoured copper power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.<br>2 core 2.5 sq mm
15
-
-
90.12.10.2 : Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
65
-
-
4.6.1 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.100 mm width X 50 mm depth X 1.6 mm thickness
Details of cost for 30 metres
10
-
-
4.6.2 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.150 mm width X 50 mm depth X 1.6 mm thickness
10
-
-
4.6.3 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.225 mm width X 50 mm depth X 1.6 mm thickness
10
-
-
MODULAR SWITCH,SCOKETS,BOXE,PLATE
-
-
-
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
15
-
-
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
15
-
-
1.27.2 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
15
-
-
1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
10
-
-
1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
10
-
-
1.26 : Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
35
-
-
1.27.4 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
5
-
-
CABLE BARE EARTHING,EARTH CLAMPS,EARTH SCOKET
-
-
-
9.1.22 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)
4
-
-
9.1.23 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)
2
-
-
9.1.20 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X25 sq.mm (28mm)
8
-
-
90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
650
-
-
90.16.5.3 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
20
-
-
PLATE EARTHING
-
-
-
5.4 : Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and
providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
4
-
-
5.8 : Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth
electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required.
(Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
30
-
-
5.9 : Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth
electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
30
-
-
5.14 : Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
80
-
-
5.15 : Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
30
-
-
5.17 : Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as
required.
70
-
-
5.19 : Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
50
-
-
WATER PUMPS
-
-
-
od313231/2023_2024 : Supply, installation, testing and commissioning of 1.5HP 3Phase Open Well Submersible Pump including installation of all accessories ,with stater (without pvc pipe) as per instruction from engineer in charge
2
-
-
MV PANEL BOARD
-
-
-
od256534/2020_2021 : Fabrication, supply, conveyance, installation testing, and commissioning floor mounting, dust and vermin proof, cubicle type LV panel board comprising the following components/ devices & complying with IS 8623. Fabrication of fully partitioned, dust and vermin-proof enclosure for panel assembly using 1.6 mm CRCA sheet as per approved design and requirement 2mm for the frame, with front access facility, bus bar chambers with aluminum bus, hinged doors for all switch gear compartments and earthing the doors using braided copper conductor and providing indication lamps, digital type Multi-function meter suitable CTs, danger notice board, etc The board should be powder coating the assembly after subjecting to 7 tank process as required. 2 Nos Copper earth bar of size 25 mm x 3 mm at the rear with 2 No. earth stud. Angles/ flats/ slotted angles etc shall not be used to fabricate panel assembly. The cubical panel board shall have 9 Nos compartments of size not less than 300 mm x 600 mm and viewing glass for all outgoing compartment doors of suitable size but not less than 100 mm x 100 mm 3 mm including providing interconnection between all the switch gears with 6 Sqmm PVC insulated copper conductor cable. The panel Board should be fitted on the base frame for the panel board using channels of class designation 75 including cutting, welding, drilling holes, painting two coats of synthetic enamel paint over a coat of zinc chromate paint bolting the frame to the panel, and to the furnished floor using required bolts<br>and nuts making good the damaged colour washing and fixing the following switch gears etc as required. (Note: All the doors should have a facility for sealing by KSEB). Incomer 200 A 4 pole SFU complete with handle assembly. Instruments 2A, C curve SP MCB - 1 set RYB indication lamp, LED type - 1 set Outgoing. 125A, TPN, SFU -3 no
1
-
-
od250435/2021_2022 : fabrication, supply, conveyance, installation testing and commissioning floor mounting, dust and vermin proof, cubicle type LV panel board comprising of the following components/ devices & complying with IS 8623. Fabrication of fully partitioned, dust and vermin-proof enclosure for panel assembly using 1.6 mm CRCA sheet as per approved design and requirement 2mm for the frame, with front access facility, bus bar chambers with aluminium bus, hinged doors for all switch gear compartments and earthing the doors using braided copper conductor and providing indication lamps, digital type Multi-function meter suitable CTs, danger notice board, etc The board should be powder coating the assembly after subjecting to 7 tank process as required. 2 Nos Copper earth bar of size 25 mm x 3 mm at the rear with 2 No. earth stud. Angles/ flats/ slotted angles shall not be used to fabricate panel assembly. The cubical panel board shall have 9 Nos compartments of size not less than 300 mm x 600 mm and viewing glass for all outgoing compartment doors of suitable size but not less than 100 mm x 100 mm 3 mm including providing interconnection between all the switch gears with 6 Sqmm PVC insulated copper conductor cable. The panel Board should be fitted on the base frame panel board using channels of class designation 75 including cutting, welding, drilling holes, painting two coats of synthetic enamel paint over a coat of zinc chromate paint bolting the frame to the panel, and the furnished floor using required bolts<br>and nuts making good the damaged colour washing and fixing the following switch gears etc as required. (Note: All the doors should have a facility for sealing by KSEB). Incomer 125 A 4 pole switch Disconnector unit (Isolator) complete with handle assembly. Instruments 2A, C curve SP MCB – 1 set RYB indication lamp, LED type - 1 set Outgoing. Providing and fixing 1 No 5 to 30 A single phase kWh meters with LCD (KSEB tested) 5 Nos32 A RW Cut out fuse….5 Nos with HRC32 A NL…5 Nos 63A DP SFU -5, <br>
1
-
-
od208356/2021_2022 : Fabrication, supply, conveyance, installation testing, and commissioning floor mounting, dust and vermin proof, cubicle type LV panel board comprising the following components/ devices & complying with IS 8623. Fabrication of fully partitioned, dust and vermin-proof enclosure for panel assembly using 1.6 mm CRCA sheet as per approved design and requirement 2mm for the frame, with front access facility, bus bar chambers with aluminum bus, hinged doors for all switch gear compartments and earthing the doors using braided copper conductor and providing indication lamps, digital type Multi-function meter suitable CTs, danger notice board, etc The board should be powder coating the assembly after subjecting to 7 tank process as required. 2 Nos Copper earth bar of size 25 mm x 3 mm at the rear with 2 No. earth stud. Angles/ flats/ slotted angles etc shall not be used to fabricate panel assembly. The cubical panel board shall have 9 Nos compartments of size not less than 300 mm x 600 mm and viewing glass for all outgoing compartment doors of suitable size but not less than 100 mm x 100 mm x 3 mm including providing interconnection between all the switch gears with 6 Sqmm PVC insulated copper conductor cable. The panel Board should be fitted on the base frame for the panel board using channels of class designation 75 including cutting, welding, drilling holes, painting two coats of synthetic enamel paint over a coat of zinc chromate paint bolting the frame to the panel, and to the furnished floor using required bolts<br>and nuts making good the damaged colour washing and fixing the following switch gears etc as required. (Note: All the doors should have a facility for sealing by KSEB ).<br>Incomer 125 A 4 pole switch Disconnector unit (Isolator) complete with handle assembly.<br>Instruments 2A, C curve SP MCB – 1 set RYB indication lamp, LED type - 1 set<br>Outgoing. Providing and fixing 1 No 5 to 30 A single phase kWh meters with LCD (KSEB tested) ……8Nos. 32 A RW Cut out fuse….8 Nos with HRC32 A NL…8 Nos 63A DP SFU -8Nos<br>
1
-
-
od344808/2023_2024 : Fabrication, supply, conveyance, installation testing, and commissioning floor mounting, dust and vermin proof, cubicle type LV panel board comprising the following components/ devices & complying with IS 8623. Fabrication of fully partitioned, dust and vermin-proof enclosure for panel assembly using 1.6 mm CRCA sheet as per approved design and requirement 2mm for the frame, with front access facility, bus bar chambers with aluminum bus, hinged doors for all switch gear compartments and earthing the doors using braided copper conductor and providing indication lamps, digital type Multi-function meter suitable CTs, danger notice board, etc The board should be powder coating the assembly after subjecting to 7 tank process as required. 2 Nos Copper earth bar of size 25 mm x 3 mm at the rear with 2 No. earth stud. Angles/ flats/ slotted angles etc shall not be used to fabricate panel assembly. The cubical panel board shall have 9 Nos compartments of size not less than 300 mm x 600 mm and viewing glass for all outgoing compartment doors of suitable size but not less than 100 mm x 100 mm 3 mm including providing interconnection between all the switch gears with 6 Sqmm PVC insulated copper conductor cable. The panel Board should be fitted on the base frame for the panel board using channels of class designation 75 including cutting, welding, drilling holes, painting two coats of synthetic enamel paint over a coat of zinc chromate paint bolting the frame to the panel, and to the furnished floor using required bolts<br>and nuts making good the damaged colour washing and fixing the following switch gears etc as required. (Note: All the doors should have a facility for sealing by KSEB). Incomer 100A 4P ATS (Automatic Transfer Switch with indicators)-1, set RYB indication lamp, LED type - 1 set Three phase kWh meters with LCD (KSEB tested) ……1 Nos. 32 A RW Cut out fuse….3 Nos with HRC32 A NL…1 Nos Outgoing 63A 4 pole Insulator for fire panel-1, 63A 4 pole SFU for solar on grid connection-1 spare SFU 63A 4 pole-1<br>
1
-
-
SOLAR
-
-
-
od258355/2020_2021 : Supply, Installation, Testing and commissioning of on grid solar photovoltaic Power Plant , Conforming to MNRE Specification as amended, consisting of Mono/Poly crystalline silicon solar cell, Net metering facility, necessary protections , earthing mounted on Aluminium /GI Structure of suitable strength with following components complete as required.<br>a)Solar photovoltaic module of capacity 330 wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part -2, Solar photovoltaic Module conversion efficiency shall not be less than 16.5%, PV Modules used in solar power plants /systems must be warranted for their out put peak watt capacity, which should not be less than 90% at the end of 10 years and 80 % at the end of 25 years.<br>b)Power conditioning unit (PCU) of 350-800 V DC input voltage range and 400 V AC, three phase 4 wire , 50 hz +/- 2.5hz, out put voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the grid voltage frequency.<br>c)Data monitoring system complete with all accessories.<br>d)Fixing of array junction box & main junction box with IP 65 Protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc as required <br>f) connection and interconnection by supplying & fixing required size XLPE insulated copper conductor 1.1 KV grade armoured power and control cable between solar modules, main power cable to grid supply PCU Unit along with supplying & fixing of necessary channel / conduit lugs and other accessories etc as required .( RATE FOR 1 kWp ) COST/kWp
10
-
-
Supply erection testing and commissioning of Twin Car Parking System
-
-
-
od260960/2022_2023 : Supply , erection, testing and commissioning of Twin Car Parking System size - Length (mm): 5050, Width (mm): 2000, Height (mm): 1700 ,SEDAN Height (mm): 2050- SUV, Lifting Capacity 2000kg, Drive Unit- Electromotor 1.5 KW, Traction Chain & Wire Rope, DC Magnetic Braking, Reducer Integrated with motor ,Travel Speed-3.5 m / min, Power Source - Main – AC 415V, 3 PH, 50HZ, Lighting – AC 220V, 1 PH, 50HZ , Operation- Push Button Control with Safety Locking, Control- Contactor Type Safety- Wheel Stopper, Safety Sensor, Proximity Sensor, ON/OFF Key Switch Push to Operating Switch Chain Guard over load protection complete as per EI & KSEB rules. Necessary approval and License shall be obtain from the EI as per the scope of the contractor
2
-
-
ACP
-
-
-
10.2 : Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
100
-
-
25.7 : Designing, fabricating, testing, installing and fixing in position Curtain Wall with
Aluminium Composite Panel Cladding, with open grooves for linear as well as
curvilinear portions of the building , for all heights and all levels etc. including:
a) Structural analysis & design and preparation of shop drawings for pressure
equalisation or rain screen principle as required, proper drainage of water to make
it watertight including checking of all the structural and functional design.
b) Providing, fabricating and supplying and fixing panels of aluminium composite
panel cladding in pan shape in metalic colour of approved shades made out of
4mm thick aluminium composite panel material consisting of 3mm thick FR grade
mineral core sandwiched between two Alumini um sheets (each0.5mm thick). The
aluminium composite panel cladding sheet shall be coil coated, with Kynar
500based PVDF / Lumiflon based fluoropolymer resin coating of approved colour
and shade on face # 1 and polymer (Service) coating on face # 2 as specified using
stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer
rods etc.
c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised
with serrations and serrated washers to arrest the wind load movement, fasteners,
SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to
prevent bi-metallic contacts all complete required to perform as per specification
and drawing The item includes cost of all material & labour component, the cost of
all mock ups at site, cost of all samples of the individual components for testing in
an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall
with aluminium composite panel cladding till the handing over of the building for
occupation. Base frame work for ACP cladding is payable under the relevant
aluminium item.s The Contractor shall provide curtain wall with aluminium
composite panel cladding, having all the performance characteristics all complete
, as per the Architectural drawings, as per item description, as specified, as per the
approved shop drawings and as directed by the Engineer-in-Charge.
However, for the purpose of payment, only the actual area on the external face of
the curtain wall with Aluminum Composite Panel Cladding (including width of
groove) shall be measured in sqm. up to two decimal places.
20
-
-
LIGHTENING PROTECTION SYSTEM
-
-
-
od344428/2023_2024 : Providing maintenance free Earthing system comprises of molecularly bonded copper of 99.9% purity on low carbon steel of 3m length, having a diameter of 14.2 mm with a copper coating thickness of 250 microns with fault current withstand capability of 13 KA rms value for 1 second and I peak of 31 KA. Universal Clamp (14 25 RTC) made of SS 304 for clamping. The earth-enhancing compound is used form improving soil conductivity. The material shall be mineral inert to the subsoil and shall not pollute the environment and non-corrosive<br>to earth rod. The material should have a resistivity of less than 0.2 Ωm. It should be free from hazardous substances The mineral compound is required to have 25 kg/pit of the total composite. Polypropylene & Polyethylene (UFE)Earth electrode inspection chamber<br>with a heavy-duty cover should be used to cover the Earth Rod. The dimension shall be 250mmx 250mmx 250mm with a weight-bearing capacity of 50KN.<br>
2
-
-
od344429/2023_2024 : Supply and installation of 8mm solid aluminium round conductor: For concrete building Meets the technical specification according to DIN EN 50164-2 (VDE 0815 part 202). Meets the requirement of VDE0185/305(IEC 62305) RD 8/ALU: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) With 50 sq. mm cross-sectional area. Polyamide Conductor holder: With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder. Weather and temperature resistance from -35 to +90 degrees Celsius was tested. Conductor holder @ 1-meter distance, including all accessories as required for complete installation as instructed by the engineer in charge. Horizontal run - Parapet application
60
-
-
od344430/2023_2024 : Supply and installation of 8mm solid aluminium round conductor: For concrete building Meets the technical specification according to DIN EN 50164-2 (VDE 0815 part 202). Meets the requirement of VDE0185/305(IEC 62305) RD 8/ALU: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) With 50 sq. mm cross-sectional area. Polyamide Conductor holder: With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder. Weather and temperature resistance from -35 to +90 degrees Celsius was tested. Conductor holder @ 1-meter distance, including all accessories as required for complete installation as instructed by the engineer in charge.Vertical run- Down conductor
55
-
-
od344431/2023_2024 : Supply, installation, and testing of 3-meter air terminal with accessories, providing and fixing air terminals as per IEC - 62305 part-3<br>16mm rod tapered to 10 mm aluminium rod: Meets the technical specification according to DIN EN 50164 - 2 (VDE 0815 part 202). Meets<br>the requirement of VDE0185/305 (IEC 62305) 101 VL 4000: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind<br>load. The system consists of Fang Fix with a base and clamp on the top air terminal is erected. Fang fix clamp made of cable bracket,<br>lightning tested for 100 KA 10/350 micro sec waveform. 2 nos of 16 KG stone of 365 mm diameter, high level of stability. Quick and<br>easy mounting of interception rod using anchors. Concrete, frost-resistant, can be stacked, including all accessories as required for<br>complete installation as instructed by the engineer in charge.
2
-
-
od344432/2023_2024 : Providing and fixing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of the hexagonal plate.
2
-
-
od344433/2023_2024 : Supply and fixing of PVC trapezoidal 1.5m long ducts including the fastening clamps and all accessories as required.
2
-
-
od344786/2023_2024 : Supply and lay hot dip Galvanised Steel Flat having 70 microns zinc 30X3 mm thick from the earth<br>electrode directly in the ground as required. Hot Dip GI strip, corrosion resistant. Cross sectional area of<br>90mm square According to DIN EN 50164-2 (VDE 0185 part 202) Meets the requirement of<br>VDE0185/305(IEC 62305) Zinc coating: 500 g/m square (70 micron coating) Should be tested and use<br>exclusively for lightning protection earthing system and ring equipotential bonding including cross<br>connectors and all accessories as<br>required for complete installation as instructed by the engineer in<br>charge.
40
-
-
od344434/2023_2024 : Supply and Fixing Equipotential bonding rail for Lightning Arrestor applications (Test Joint). Equipotential bonding rail for equipotential bonding according to DIN VDE 0100-410/540 and lightning protection equipotential bonding according to DIN VDE 0185-305. Base plate and cover hood from polystyrene. Colour: Black, UV resistant. It can be used outdoors also. Screw and crossbar made of VA. Capable of carrying lightning current 100KA (10/350). Connection options: 7 x single or multi-core conductors to 25mm square or fine core conductors to 16mm square. 1 x round cable Rd 8-10. 1 x flat strip to FL 30 or round cable RD 8-10 including corrosion tapes and all accessories as required for complete installation as instructed by the engineer in charge.
2
-
-
od344435/2023_2024 : Supply and fixing of expansion piece with connector: For equalising temperature-related length changes. Necessary on conductors length over 20 meters. For round conductor Rd 8/ALU. Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanized. Conforms to the requirements according to DIN VDE 0185-305 (IEC 62305) and all accesories as required for complete installation
5
-
-
od344436/2023_2024 : Supply and fixing of cross connector / T connector: to route vertical down conductor /mesh formation made of stainless steel/hot dipped galvanized iron with necessary screws etc as required. Installed with 4 hexagonal bolts M8*25 with M8 hexagonal nuts and all accessories as required for complete installation
3
-
-
od344437/2023_2024 : Supply and installation of 8mm solid aluminium round conductor: For TERRACE APPLICATION Meets the technical specification according to DIN EN 50164-2 (VDE 0815 part 202). Meets the requirement of VDE0185/305(IEC 62305) RD 8/ALU: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) With 50 sq. mm cross-sectional area. Stainless steel base with Polyamide Conductor holder top: Adjustable width from 185-260mm. Infinitely adjustable conductor holder. Fast installation using wing screw. Bottom section with 8.5mm<br>diameter slot With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder. Weather and temperature resistance from -35 to +90 degrees Celsius were tested. Conductor holder @ 1-meter distance<br>
40
-
-