Kerala State Film Development Corporation Limited Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 50,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_KSFDC_306169_1Bid Award Id
ViewTender No
3667/T2/19/KSFDCTender Authority
Kerala State Film Development Corporation Limited ViewPurchaser Address
-Website
http://etenders.kerala.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Control cabling of package/Split units
1
-
-
REFRIGERANT PIPING
-
-
-
Liquid line - Refrigerant piping with 19mm thick nitrile rubber insulation and with glass cloth & foaster painting.
65
-
-
suction line - Refrigerant piping with 19mm thick nitrile rubber insulation and with glass cloth & foaster painting.
65
-
-
Drain Water Piping
-
-
-
Supply and fixing in position of condonsate drain water &indoor unit drain to the floor trap piping with 19 mm thick nitrile rubber insulation and with necessary fittings like elbows,tees and reducers etc.25 mm PVC
40
-
-
SHEET METAL WORK - Supply, fabricate, handle and erect factory fabricated GSS ducting as per drawing, complete with all fittings such as tee bends, special off-chutes, turning vanes, splitter dampers, ins.doors, transformation pieces slip on flanges etc. as reqd. as per IS 655 including suspension and supporting arrangement for plenums, ducts, complete as reqd. and as per specs. (only hitech supports shall be used) wall opening as good as same - Rectangular Duct
-
-
-
1. 0.63mm GSS ducting in sq.m.
325
-
-
2. 0.80mm GSS ducting in sq.m.
170
-
-
3. 1.00mm GSS ducting in sq. m.
45
-
-
4. 1.25mm GSS ducting in sq.m.
1
-
-
GRILLES & DIFFUSERS
-
-
-
Supply and fix the following grilles and diffusers as per specifications. Machine made, powder coated, supply and return air grilles and diffusers of design to be approved (material : Al)supply air grille with vcd
10
-
-
return air grille w/o vcd
20
-
-
Factory made fresh air dampers with louvers and control lever.
1
-
-
DUCT DAMPERS
-
-
-
Supply, fix, balance, and commission louvre type smooth supply air duct dampers made of extruded aluminium linkage, lever, fixing arrangement etc.complete brass bushings
3
-
-
FIRE DAMPERS.
-
-
-
Supply and fix 1 1/2 hour fire rated fire dampers air ducts (main line) with fusible link & microswitch to shut of corresponding Ahu (including control cable.)
3
-
-
DUCT INSULATION & LINING
-
-
-
Thermal insulation supply & fixing of 9 mm thick class o nitrile rubber insulation with adhesive as per the recommendation of the manufacture with density 45-55kg/m3
450
-
-
Acoustic insulation supply & fixing of 10 mm thick armafoam insulation with adhesive as per the recommendation of the manufacture with density 140-180kg/m3
75
-
-
Non ac area duct insulationsupply & fixing of 19 mm thick armacell insulation with adhesive as per the recommendation of the manufacture with density 45-55kg/m3
10
-
-
ACCOUSTIC LINING OF PACKAGE UNIT ROOMS
-
-
-
Supply, installing and testing of accoustic lining of AHU rooms, walls and ceiling with 15 mm thick nitrile rubber with adhesive as per the recommendation of the manufacture with density 140-180kg/m3
310
-
-
EXPOSED ROOF INSULATION
-
-
-
supply & fixing of 13 mm thick class o nitrile rubber insulation with adhesive as per the recommendation of the manufacturer with density 40-60kg/m3
1
-
-
Inspection of the existing package units, split Units & AHU (capacity as per existing basis of design) to ascertain the performance and making good of the same in working condition to the satisfaction of the client. Work includes gas charging , repair work of damages, insulation ducting, pc boards, switches, indicaton lamps etc.
-
-
-
Kairali Below Balcony - 7000 Cfm DX AHU, 2 Nos. & Condensing Unit
1
-
-
Kairali Balcony - 9000 cfm DX AHU, 1 No. & Condensing Unit
1
-
-
Sree - 9000 cfm DX AHU, 1 No. & Condensing Unit
1
-
-
Dismantling
-
-
-
Dismantling, removing and reinstallation of existing 2 x 4.5 TR floor standing split units to the new place advised by the client and making good of the same in working condition to the satisfaction of the client. Work includes gas charging, repair work of damages, pc boards, switches, indication lamps etc. include refrigerant piping 15 Mts. / unit
1
-
-
Dismantling, removing and reinstallation of existing 4 x 1.5 TR Hiwall split units to the new place advised by the client and making good of the same in working condition to the satisfaction of the client. Work includes gas charging, repair work of damages, pc boards, switches, indication lamps etc. include refrigerant piping 15 Mts. / unit
1
-
-
Removal of the existing ducting wherever not required and interconnecting new and existing ducting as per new design and keeping in place as directed by KSFDC
1
-
-
Digital Display unit
-
-
-
Digital display unit inside the theatre to display temperature inside the theatre with necessary control cable from unit etc for all theaters
3
-
-
Metal frame work for hanging 11 TR Split unit
1
-
-
AMC -NEW UNITS
-
-
-
Annual maintenance contract charges including spares , gas and consumbles for the above plant per year for 5 years on per ton basis and percentage increase every year for 4 years after warrenty period of 1 year. The frequency of servicing shall be one in 3 months every year for routine service and immediate on break down calls.1st year
16.5
-
-
2nd year
16.5
-
-
3rd year
16.5
-
-
4th year
16.5
-
-
AMC - OLD UNITS
-
-
-
Annual maintenance contract charges including spares , gas and consumbles for the above plantper year for 5 years on per ton basis and percentage increase every year The frequency of servicing shall be one in 3 months every year for routine service and immediate on break down calls.1st year
140.5
-
-
2nd year
140.5
-
-
3rd year
140.5
-
-
4th year
140.5
-
-
5th year
140.5
-
-
Evaluation Notes How It Works ?