Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Kerala State Film Development Corporation Limited - KSFDC Tender
Civil And Construction
Eprocure
Opening Date14 Mar 2023
Closing Date3 Apr 2023
Tender Amount₹ 8,62,089
Costs
EMD
₹ 12,930Document Cost
₹ 1,725Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_KSFDC_566315_1Bid Award Id
ViewTender No
3079/T1/22/KSFDCTender Authority
Kerala State Film Development Corporation Limited ViewPurchaser Address
-Website
http://etenders.kerala.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
The quote should be inclusive of control cabling from machine out door unit to indoor unit and from from DB to indoor unit power cabling along with earthing. This shall facilitate all functions such as ON OFF thermostat to compressor control, fan interlocks, HP/LP & AFT controls etc. And MS base frame for outdoor units (including Catwalk support of MS base frame with C Channel and L angles for outdoor units for maintenance purpose) complete with epoxy painting, vibration isolation pads, supports, hangers, railing, brackets etc including civil works. Note: Apply 2 coats of epoxy primer and 2 coats of black paint, Each air conditioner unit should be provided with 10 Rmt. of copper piping between Indoor unit to outdoor unit as specified in (1.2) Refrigerant piping. The refrigerant shall be eco-friendly gasses like HFC, R 410A or latest, These eco friendly refrigerants shall be with zero Ozone depleting substances. Commissionming of the system with refrigerant gas after necessary pressure holding for 24Hrs upto 500PSI nitrogen and charging of the system after necessary vaccuming etc price shall be Inclusive of leading, shifting, positioning and Installation of ductable indoor / outdoor units, transportation, etc
-
-
-
16.50 TR ( 21HP) - Ceiling Suspended Ducted type (400 CFM/TR) Inverter type compressor
1
-
-
REFRIGERANT PIPING
-
-
-
Installation and commissioning of hard/soft copper refrigerant piping, complete with Nitrile Insulation, fittings, elbows, bends, supporting arrangement on walls, cable trays/trenches.( FOR MACHINES HAVING PIPE LENGTH LONGER THAN 20 MTS, RESIZE USING LARGER DIA.). The suction & liquid line shall be insulated with 13 mm thick tubular nitrile rubber insulation with weather protection for outdoor installation. The piping length estimated based on considering single loop & single line distance (Ref. Ppg in bunches –16.5TR AC Unit with 1 No. 11 TR and 1 No 5.5 TR Compressors and 1 RMT of 2 sets of Ref Pipes i.e., 4 Nos. Pipes in all considered as 1 RMT) . The contractor to quote based on the estimate of actual length according to the number of loops for corresponding. Including beam/wall cutting , making good of civil works etc.
-
-
-
16.5 TR - Ceiling Suspended Ducted type
16
-
-
DRAIN PIPING:
-
-
-
Supply, installation, testing & commissioning of following sizes. insulated PVC drain pipe' from AHU drain pans to nearest floor drain complete with interconnection, flanges, elbows, tees, nuts, U-trap etc. The insulation shall be 6 mm thick closed cell Class O Nitrile Rubber foam insulation. Including wall cutting , making good of civil works etc 32mm dia. --- 1" nominal dia --- 2kgf/ sq. cm --- class 2
7
-
-
AIR DISTRIBUTION SYSTEM
-
-
-
SHEET METAL WORKS:
-
-
-
Supply, Fabrication, installation, testing & commissioning of Factory fabricated GI spiral oval ducts complete with splitter dampers, turning vanes, access doors, supports, etc Ducting to be as per SMACNA standards. Galvanizing shall be class VII-light coating of zinc, nominal 120 gm/sq.m and lock forming quality prime material. Duct coil ( sheet metal in Roll form) lines to facilitate location of longitudinal seams at corner/folded edges only, for required duct rigidity and leakage free characteristics. No longitudinal seams permitted along any face side of the duct. All ducts, transformation pieces and fittings to be made on CNC profile cutter for requisite accuracy of dimensions, location and dimensions of notches at the folding lines. all edges to be machine treated using lockformers,flanges and rollers for turning up edges. Reinforcement, bracing, supporting etc to comply with SMACNA standards.
-
-
-
All oval duct work shall be pre-insulated internaly with 10mm thick acoustic insulation open cell elastomeric nitrile foam rubber insulation class stuck to duct as per specifications provided in item number 3.2 Acoustic insulation
-
-
-
Apart from oval duct work all exposed duct work should be painted with 2 coats of epoxy primer and 2 coats of epoxy paint. All the supports of the duct will be painted to match the ducting.
-
-
-
24 Gauge preinsulated oval duct work
60
-
-
22 Gauge preinsulated oval duct work
20
-
-
20 Gauge preinsulated oval duct work
10
-
-
Supply, Fabrication, installation, testing & commissioning of Site fabricated GSS ducting complete with splitter dampers, turning vanes, access doors, supports, etc Ducting to be as per SMACNA standards. Galvanizing shall be class VII-light coating of zinc, nominal 120 gm/sq.m and lock forming quality prime material.
-
-
-
All exposed duct work should be painted with 2 coats of epoxy primer and 2 coats of epoxy paint All the supports of the duct will be painted to match the ducting
-
-
-
24 Gauge
10
-
-
22 Gauge
10
-
-
Supply, testing, commissioning and balancing of one way blow 16G extruded aluminum powder coated continuous Linear grilles for supply and return air with 4 side flanges and as per approved colour shade by the architect.
-
-
-
Supply air part shall be equiped with collar dampers multi opposed blade as per specification.
1.5
-
-
Return air grill wihout collar dampers
1
-
-
Supply, installation, testing and commissioning of multi blade opposed blade GSS dampers for ducts to be provided with suitable links, levers and quadrants for manual control of volume of air flow and for proper balancing of the air distribution system .
1
-
-
INSULATION WORKS
-
-
-
THERMAL INSULATION
-
-
-
Supply Installation, Testing and commissioning of Supply Duct insulation 13mm thick closed cell elastomeric nitrile foam rubber insulation class stuck to duct as per specifications
-
-
-
Thermal insulation material for ducts shall be 13mm closed cell elastomeric non polar UV resistant-UL94-Class-O and Nitrosmine free. Nitrile Rubber/EPDM of thermal conductivity of the insulation material shall not exceed 0.038 W/m K at an average temperature of of 30 degC. Density of nitrile rubber shall be 40-60 Kg/m3. The product shall have temperature range of -40 deg C to 105 deg C. The insulation material shall be fire rated for Class O as per BS 476 Part 6: 1989 for fire propagation test and for Class 1 as per BS 476 Part 7,1987 for surface spread of flame test. Water vapor permeability shall not less then 0.024 per inch ( 2.48x10-14 Kg/m.s Pa ) as per DIN 53122 part DIN 52615.
-
-
-
13 MM Nitrile Rubber
60
-
-
ACOUSTIC INSULATION
-
-
-
Inside lining of oval duct / rectangular duct work shall be pre-insulated internaly with 10mm thick acoustic insulation open cell elastomeric nitrile foam rubber insulation class stuck to duct as per specifications upto 6 mtrs from the machine mouth.
-
-
-
Acoustical insulation material for ducts shall be 10 mm open cell elastomeric non polar – UV resistant-UL94-Class- 1 - and Nitrosmine free. Nitrile Rubber/EPDM of thermal conductivity of insulation material shall not exceed 0.046 W/m K at an average temperature of of 30 degC. Density of nitrile rubber shall be 120-140 Kg/m3. The product shall have temperature range of -40 deg C to 105 deg C. The insulation material shall be fire rated for Class 1 as per BS 476 Part 7: (1989 for fire propagation test and for Class 1 as per BS 476 Part 7,1987 for surface spread of flame test.) Water vapor permeability shall not less then 0.024 per inch (2.48x10-14 Kg/m.s Pa ) as per DIN 53122 part DIN 52615.
-
-
-
10 MM Nitrile Rubber
1
-
-
AMC
-
-
-
Comprehensive: Annual maintenance contract charges Including spares , gas and consumables for the above plant per year for 5 years on per ton basis and percentage increase every year for 4 years after warranty period of 1 year. The frequency of servicing shall be once in 3 months every year for routine service and immediate on break down calls. (Base price w/o GST)
-
-
-
1st year
16.5
-
-
2nd year
16.5
-
-
3rd year
16.5
-
-
4th year
16.5
-
-
5th year
16.5
-
-
Non comprehensive: Annual maintenance contract charges Excluding spares , gas and consumables for the above plant per year for 5 years on per ton basis and percentage increase every year for 4 years after warranty period of 1 year. The frequency of servicing shall be once in 3 months every year for routine service and immediate on break down calls. (Base price w/o GST)
-
-
-
1st year
16.5
-
-
2nd year
17.5
-
-
3rd year
18.5
-
-
4th year
19.5
-
-
5th year
20.5
-
-