Kerala State Film Development Corporation Limited Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kerala State Film Development Corporation Limited - KSFDC Tender

Works
Eprocure
Opening Date26 Feb 2021
Closing Date20 Mar 2021
Tender Amount₹ 49,85,793 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply, Installation testing and commissioning of split air cooled Air-conditioners each complete with scroll compressor, air cooled condensor, GSS casing, filters, cooling coils, fan motors, insulated copper refrigerant piping as per drawing, control wiring, refrigerant controls and accessories, including MICRO-PROCESSOR CONTROL with indication lamps for the operation of the system with thermostat fixed in the respective rooms to adjust the temperature according to the equipments requirements with Micro- processor control panel for each machine. Tenderes to elaborate the features of Micro- processor panel. Control cabling, power cable of isolator to indoor units and earthing of units as per the scope of electrical Inspectorate to be included. GI Paintes frame works for out door units & making good of civil works . Refrigerant shall be R 410. Price shall inclusive of , installation, commissioning, Refrigerant piping as manufacturere's specification. 1.5 TR Split unit - Inverter type- with smart sensor enabled -1 year warranty on machine and 10 years on compressor. 3 Mtr Copper Pipe Included 100% Copper Condenser Coil

10

-

-

... More
REFRIGERANT PIPING

-

-

-

... More
Liquid line - Refrigerant piping with 19mm thick nitrile rubber insulation and with glass cloth & foaster painting.

250

-

-

... More
Discharge line - Refrigerant piping with 19mm thick nitrile rubber insulation and with glass cloth & foaster painting.

250

-

-

... More
Insulation for existing Refrigerant pipe: Liquid line - with 19mm thick nitrile rubber insulation and with glass cloth & foaster painting.

200

-

-

... More
Insulation for existing Refrigerant pipe: Discharge line - with 19mm thick nitrile rubber insulation and with glass cloth & foaster painting.

200

-

-

... More
Drain Water Piping

-

-

-

... More
Supply, installation, testing & commissioning of following sizes. insulated PVC drain pipe' from AHU drain pans to nearest floor drain complete with interconnection, flanges, elbows, tees, nuts, U-trap etc. The insulation shall be 6 mm thick closed cell Class O Nitrile Rubber foam insulation. 25 mm PVC

100

-

-

... More
Supply, installation, testing & commissioning of following sizes. insulated PVC drain pipe' from AHU drain pans to nearest floor drain complete with interconnection, flanges, elbows, tees, nuts, U-trap etc. The insulation shall be 6 mm thick closed cell Class O Nitrile Rubber foam insulation. 32 mm PVC

10

-

-

... More
Supply, installation, testing & commissioning of following sizes. insulated PVC drain pipe' from AHU drain pans to nearest floor drain complete with interconnection, flanges, elbows, tees, nuts, U-trap etc. ( Without Insulation) 25 mm PVC

5

-

-

... More
Supply, installation, testing & commissioning of following sizes. insulated PVC drain pipe' from AHU drain pans to nearest floor drain complete with interconnection, flanges, elbows, tees, nuts, U-trap etc. ( Without Insulation) 32 mm PVC

10

-

-

... More
SHEET METAL WORK Supply, fabricate, handle and erect factory fabricated GSS ducting as per drawing, complete with all fittings such as tee bends, special off-chutes, turning vanes, splitter dampers, ins.doors, transformation pieces slip on flanges etc. as reqd. as per IS 655 including suspension and supporting arrangement for plenums, ducts, complete as reqd. and as per specs. (only hitech supports shall be used) wall opening as good as same Rectangular Duct

-

-

-

... More
0.63mm GSS ducting in sq.m.

800

-

-

... More
0.80mm GSS ducting in sq.m.

100

-

-

... More
1.00mm GSS ducting in sq. m.

45

-

-

... More
1.25mm GSS ducting in sq.m.

1

-

-

... More
GRILLES & DIFFUSERS

-

-

-

... More
Supply and fix the following grilles and diffusers as per specifications. Machine made, powder coated, supply and return air grilles and diffusers of design as per site condition to be approved (material : Al) supply air grille with vcd

20

-

-

... More
Supply and fix the following grilles and diffusers as per specifications. Machine made, powder coated, supply and return air grilles and diffusers of design as per site condition to be approved (material : Al) return air grille w/o vcd

5

-

-

... More
DUCT DAMPERS

-

-

-

... More
Supply, fix, balance, and commission louvre type smooth supply air duct dampers made of extruded aluminium linkage, lever, fixing arrangement etc.complete brass bushings

1

-

-

... More
FIRE DAMPERS

-

-

-

... More
Supply and fix 1 1/2 hour fire rated fire dampers air ducts (main line) with fusible link & microswitch to shut of corresponding Ahu (including control cable.)

1

-

-

... More
Factory made fresh air dampers with louvers and control lever.

1

-

-

... More
DUCT INSULATION & LINING

-

-

-

... More
Thermal insulation supply & fixing of 9 mm thick class o nitrile rubber insulation with adhesive as per the recommendation of the manufacture with density 45-55kg/m3

200

-

-

... More
Acoustic insulation supply & fixing of 10 mm thick armafoam insulation with adhesive as per the recommendation of the manufacture with density 140-180kg/m3

100

-

-

... More
Non ac area duct insulation Supply & fixing of 19 mm thick armacell insulation with adhesive as per the recommendation of the manufacture with density 45-55kg/m3

1000

-

-

... More
ACCOUSTIC LINING OF PACKAGE UNIT ROOMS

-

-

-

... More
Supply, installing and testing of accoustic lining of AHU rooms, walls and ceiling with 15 mm thick nitrile rubber with adhesive as per the recommendation of the manufacture with density 140-180kg/m3

50

-

-

... More
Checking of existing accoustic lining of AHU rooms, walls and ceiling , repairing/fixing the existing mesh with nails etc required , and providing one layer of new Aluminium perforated mesh at 75 cm height from floor level including supply and installation of Aluminium perforated polished mesh with 0.6 mm

100

-

-

... More
EXPOSED ROOF INSULATION

-

-

-

... More
Supply & fixing of 13 mm thick class o nitrile rubber insulation with adhesive as per the recommendation of the manufacturer with density 40-60kg/m3

1

-

-

... More
Inspection of the existing package units to ascertain the performance and making good of the same in working condition to the satisfaction of the client. Work includes gas charging , repair work of damages, Canvas replacement, PC boards, switches, indicaton lamps, painting of stands of out door units and rusted portion of out door units by scrapping, sand papering and preparing the surface smooth etc. 5 Nos 22 TR, 3 No 11 TR & its Condensing Unit

1

-

-

... More
Inspection of the existing Hi-wall split units to ascertain the performance and making good of the same in working condition to the satisfaction of the client. Work includes gas charging , repair work of damages, PC boards, switches, indicaton lamps, painting of stands of out door units and rusted portion of out door units by scrapping, sand papering and preparing the surface smooth etc. 5 Nos 1.5 TR & its Condensing Unit

1

-

-

... More
Dismantling, removing and reinstallation of existing 2 x 1.5 TR Hiwall split units to the new place advised by the client and making good of the same in working condition to the satisfaction of the client. Work includes gas charging, repair work of damages, pc boards, switches, indication lamps, painting with epoxy paint of stands of out door units and rusted portion of out door units by scrapping, sand papering and preparing the surface smooth etc. include refrigerant piping 15 Mts. / unit

1

-

-

... More
Removal of the existing ducting wherever not required and interconnecting new and existing ducting as per new design and keeping in place as directed by KSFDC

1

-

-

... More
Supply and fix 400mm dia Jet diffusers of powder coated Aluminium as per standards

7

-

-

... More
Supply and fix Chicken Mesh on the ducts for protecting duct insulation as per standards

750

-

-

... More
Earthing: Supply, fixing and give termination to following wires for effective earthing of neutral and equipment of the old AC units. No.10 SWG Cu

600

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.