Kerala State Film Development Corporation Limited Tender

... More
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kerala State Film Development Corporation Limited - KSFDC Tender

Eprocure
Opening Date22 Jun 2021
Closing DateCancelled
Tender Amount₹ 32,54,23,708 
Notes
Download

Costs

Summary

Modernisation Of Chitranjali Studio Tvpm- Package 1 (retender-1)

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
NOTICE INVITING TENDER for Modernisation of Chitranjali Studio at Thiruvananthapuram, Kerala- Package-1 (This is a retender of the tender No - 1575/P1/18/KSFDC/Project-9 dtd 20/05/2021 , tender ID-2021_KSFDC_423486_1 cancelled due to technical reason
Bill of Quantities
Prebid meeting(Conducted on 10/6/2021)-minutes-corrigendum-reply to queries
Part V (Technical Specifications)
Part I (Instructions to the Bidders) and Part II (General Conditions of Contract )
Part VI (Pre-Qualification Information) and Part VII (Forms and Declarations)
Part III (Special Conditions of Contract) and Part IV (Contract Data)
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed. Ordinary rock

1128.7

-

-

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.

2331.27

-

-

... More
Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials. All kinds of soil

31

-

-

... More
Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials. Ordinary or hard rock

746.51

-

-

... More
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared

586.44

-

-

... More
Providing anti termite treatment Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.: With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration

801.99

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 

417.3

-

-

... More
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing :1:1½:3 (1 cement : 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size).

16.39

-

-

... More
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing : 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

2.02

-

-

... More
Providing and laying up to floor five level reinforced cement concrete in kerbs, steps and the like excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).

47.94

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Foundations, footings, bases of columns, etc. for mass concrete

827.69

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for all heights :Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. 

1239.44

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for all heights :Suspended floors, roofs, landings, balconies and access platform

3377.58

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Lintels, beams, plinth beams, girders, bressumers and cantilevers

5171.64

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for all heights :Columns, Pillars, Piers, Abutments, Posts and Struts

2795.3

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for all heights :Stairs, (excluding landings) except spiral-staircases

122.23

-

-

... More
Extra additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5m, for every additional height of 1 metre or part thereof (Plan area to be measured). 

3030.99

-

-

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.

153737.47

-

-

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending,placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500

232784.28

-

-

... More
Providing and fixing in position 12 mm thick bitumen impregnated fibre board conforming to IS: 1838, including cost of primer, sealing compound in expansion joints. 

53.03

-

-

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately) - All works upto plinth level

1029.46

-

-

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately) - Above plinth level upto floor five level

1135.79

-

-

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in plinth Cement Mortar 1:6 (1 cement : 6 coarse sand).

95.07

-

-

... More
Brick work with common burnt clay F.P.S (non modular) bricks of class designation 7.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) 

308.93

-

-

... More
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand)

23.35

-

-

... More
Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work.

8.63

-

-

... More
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with: 

63.95

-

-

... More
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvillinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-charge. a. Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. 

88.63

-

-

... More
Providing and fixing of factory made 40mm thick marine ply, Veneer finished flush door shutters of approved make and design, shutters fixed to Dorma BB 4430 or equivalent 100x75x3mm (heavy duty) 3 nos of ball bearing hinges, class 8, in satin stainless steel finish grade 304 to BS 7352, with necessary SSS screws including any additional lipping/cutting, plaining, etc.

375.26

-

-

... More
Providing and fixing 30mm thick ISI marked flush door shutters conforming to IS : 2202(Part I) non-decorative type, core of block board construction with frame of1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters

121.58

-

-

... More
Providing and fixing M.S. grills of required pattern in frames of windows etc.with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.

7032.87

-

-

... More
Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant included ). Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Casement cum fixed panel window having both end single casement panel, middle fixed panels and at top completely fixed ventilator with S.S friction hinges (350 x 19 x 1.9) made of (big series) frame 67 x 60 mm , sash 67 x 80 mm , & mullion 67 x 80 mm all having wall thickness of 2.3 ± 0.2 mm and single glazing bead/double glazing bead of appropriate dimension. (Area of window above 3.00 sqm up to 5.00 sqm).

27

-

-

... More
Providing and fixing factory made uPVC white colour fixed glazed windows/ ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), , uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, Float glass panes of 5.50 mm thickness all complete as per approved drawing & direction of Engineer-in-Charge.

26.94

-

-

... More
Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) - Two track two panels sliding window made of (small series) frame 52 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 1.75 sqm)

10.08

-

-

... More
Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of (small series) frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 +/- 0.2 mm and single glazing bead of appropriate dimension (Area of window upto 1.75 sqm). No Item heading

4.5

-

-

... More
Providing and fixing of Wooden FInish UPVC (Unplascticised Poly Vinyl Chloride) three track Sliding Window using 60mm x 37mm outer frame with door Sash of 39 x 75mm frame and all sections shall reinforced with galvanised steel. The Glazed shutters are fixed with 6mm clear float glass fixed with EPDM gasket and co extruded beadings with Espag locking system. The door frame is fixed to the walls using fasteners and to be sealed as external and internal surfaces using weather resistant Silicon sealant of approved make complete as per drawing.

332.01

-

-

... More
Providing and fixing factory made uPVC white colour sliding glazed door comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension uPVC extruded glazing beads, uPVC extruded interlock and uPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle with key on one side of extreme panels along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) cresent lock (if required), stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-inCharge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately).Two track two panels sliding door made of (big series) frame 67 x 50 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door above 2.00 sqm upto 5.00 sqm)

14.4

-

-

... More
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

42167.09

-

-

... More
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces

13.92

-

-

... More
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 m long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.

81.3

-

-

... More
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped - Hot finished welded type tubes

38461.56

-

-

... More
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete

3366.94

-

-

... More
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer - M.S. tube

234

-

-

... More
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels,plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge.

52.8

-

-

... More
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows all complete with : 4.0 mm thick glass panes

14.58

-

-

... More
Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer In charge. 

364.5

-

-

... More
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete - 40 mm thick with 20 mm nominal size stone aggregate

1706.97

-

-

... More
52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete 

3565.03

-

-

... More
40 mm thick fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand), including pointing with cement mortar 1:2 (1 cement : 2 stone dust) with an admixture of pigment to match the shade of stone. - White Sand Stone.

30

-

-

... More
Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 

1425.97

-

-

... More
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete.

661.05

-

-

... More
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete - Tile Size : - 600mm X 600MM.

3370.18

-

-

... More
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 

1195.65

-

-

... More
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square SUB HEAD : 12- ROOFING 742 edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :12.5 mm thick tapered edge gypsum fire resistant board conforming to IS: 2095- Part I

3295.35

-

-

... More
Providing and Fixing 15 mm densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture spintone /cosmos /Hexa or equivalent of size 595x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main 'T' runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross "T" of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main 'T' of size 24 x 28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main'T' at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross 'T' of length 600 mm and size 24x28 mm made of 0.33 mm thick (minimum) sheet to be inter locked at middle of the 1200x600 mm panel to from grid of size 600x600 mm, resting on periphery walls/partitions on a Perimeter wall angle pre-coated steel of size (24x24x3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture (Spintone / Cosmos/hexa) in the grid, including cutting / making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever require. Main 'T' runners to be suspended from ceiling using G.I slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size of 85x30x0.8 mm, spaced at 1200mm centre to centre along main 'T' bottom exposed with 24 mm of all T- sections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by by engineer-in-charge. Note:- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm. The calcium silicate ceiling tiles shall have NRC. value of 0.50 (Minimum), light reflection 85% non - combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity 0.043 w/m 0 KC. 

32.34

-

-

... More
12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand)

16882.06

-

-

... More
Ceiling Plastering with CM 1:3, 6mm thick

8376.58

-

-

... More
Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) :Flush/ Ruled pointing

123.72

-

-

... More
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work

3669.73

-

-

... More
French spirit polishing - Two or more coats on new works including a coat of wood filler

593.27

-

-

... More
Distempering with Ist quality acrylic distemper, having VOC (Volatile Organic Compound) content less than 50 grams /litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. 

23628.87

-

-

... More
Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture including applying additional coats wherever required, to achieve even shade and colour. 

12726.86

-

-

... More
Painting with synthetic enamel paint, having VOC (Volatile Organic Compound)content less than 150 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats

6783.53

-

-

... More
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 meters lead: With cement mortar 1:4 ( 1 cement : fine sand) 

20

-

-

... More
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge - With cement mortar 1:4 (1cement: 4 coarse sand)

1.38

-

-

... More
Making the opening in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface i/c disposal of mulba/ rubbish to the nearest municipal dumping ground, all complete as per direction of Engineer-in-Charge.For door/ window/ clerestory window

22.32

-

-

... More
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete

2785.16

-

-

... More
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.

5966.05

-

-

... More
Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of durationof scaffolding. Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done

3869.29

-

-

... More
Providing & fixing White vitreous china water closet squatting pan (Indian type) along with "S" or "P" trap including dismantling of old WC seat and "S" or "P" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the directionof Engineer-in charge - Orissa pattern W.C Pan of size 580x440 mm

25

-

-

... More
Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge

2110.76

-

-

... More
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.

32.36

-

-

... More
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. - In Cement mortar

131.23

-

-

... More
Dismantling dressed stone work ashlar face stone work, marble work or precast concrete work manually/ by mechanical means including stacking of serviceable and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge :

258.29

-

-

... More
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead - Of area 3 sq. metres and below

176

-

-

... More
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead - Of area beyond 3 sq. metres

56

-

-

... More
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm

2034.24

-

-

... More
Dismantling wooden trellis work excluding frames but including stacking the serviceable material within 50 metres lead.

37.62

-

-

... More
Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead :100 mm dia pipe

248.27

-

-

... More
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.

3559.34

-

-

... More
Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge.

454.85

-

-

... More
Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved s;ze, design & shape, laid in required colour and pattern over and ncluding 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.

2362.03

-

-

... More
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts , bolts and washers as required complete as per the direction of Engineer-in- charge. Made of G.I wire of dia 4 mm. PVC coated to achieve outer dia. not less than 5 mm in required colour and shade.

216

-

-

... More
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30

590.51

-

-

... More
Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with echanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge.

354.31

-

-

... More
Providing and fixing APP ( Atactic Polypropylene Polymer) modified prefabricated five layer 2 mm thick water proofing remembrance, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrance manufacture of density at 250C, 0.87 - 0.89 kg/ litre and viscocity 70- 160 cps. Over the primer coat the layer of membrane shall be laid using Butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 230C as 350/ 300 N/5cm. Tear strength in longitudinal and transverse direction as 60/80 N. Softening point of membrane not less than 1500C. Cold flexibility shall be upto - 20C when tested in accordance with ASTM, D- 5147 The laying of membrane shall be got done through the authorised applicator of the manufacture of membrane. 

805

-

-

... More
Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in- Charge

44.09

-

-

... More
Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge 

1594.9

-

-

... More
Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete 

3.29

-

-

... More
Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete

986.57

-

-

... More
Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete 

31.85

-

-

... More
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood 

6.79

-

-

... More
Providing and fixing PVC pipes includes joints of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 110 mm dia 4 Kg/cm2 

27.6

-

-

... More
Suplying Fabricating and Fixing in position of single leaf aluminium anodized natural colour matt finish door with frame using frame section 101.64x44.45x3.18mm for vertical style and horizontal piece, shutters section for top, middle and vertical style of size 50x44.45x2.50mm board section of size 100x44.45x2.50mm half glazed 5.50mm thick and half PLB board 12mm thick glazed door using rectangular aluminium box section with necessary accessories such as rubber beading, aluminium chips, best double action door closer with handles, locks and glass etc., including all materials, labour and power consumption charges required for fabrication if necessary chiping, dismantling making necessary holes in RCC columns, beams or masonry wherever necessary with power drill to the extent required and made good to the original condition after fixing etc., complete. The aluminium surface should be anodized with matt finish under electrically controlled condition in accordance with ISI specification 1868/1962 of anodic film thickness of not less than 15 microns for all sections. All the materials should be got approved by the Engineer - in - Charge before fixing in position and as directed by the departmental officers.

2.1

-

-

... More
Supply & Installation for Fire Rate Acoustic Door – CONFORMS TI IS 3614 (PART 2) 1992 BS476 (PART 20 & 22) – Door Size: 1500mm(W) x 2100mm(H) Wall Opening Width (W): 1500mm Wall Opening Height(H): 2100mm Profile Size – Single Rebate: 100*58 Door Thickness: 46mm Infill Material: 25mm with density 1000GSM Frame Sheet Tickness:1.6mm Shutter Sheet Thickness: 1.2mm Finish- PU Paint/ Laminate Door Type: Fire Door with Acoustic Treatment Number of Door Leaf: Single Door Accessories: SS Ball Bearing Butt Hinges, Anchor Fastener, Door Closure with Standard Arm, Dead Lock Both side operated lock & Key, SS D Handle on both sides, Fire rated Glass-200x300mm with panel & tape for glass fixing, Concealed Flush Bolt- 600mm, All tight seal (RM) Door (Drop) Bottom Seal.

3

-

-

... More
Fabricating, Supplying and Fixing in position MS Staircase railings with Top hand rail of Teak wood member of 100 mm dia of First class teak wood fixed to be as railing connected to the verticals made of combination of 50x50mm 14 SWG corner posts & 16x16mm 14 SWG intermediate posts @ ~ 355mm through 25mm dia connectors. There shall 2 horizontal members of 20x20mm 14SWG connected to the wall at the ends & to the verticals as shown in the detailed drawing. There shall be additional intermediate posts @ 118mm c/c between the mid-rails. Balusters should be fixed to the concrete slabs through connector plates & cap plates as per the detail drawings. All MS will be Enamel painted finish with base primer coat as per Project Consultants / Site in charge instructions.

59.91

-

-

... More
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement,teak wood jamb (75mmx225mm) and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-incharge

3.78

-

-

... More
Dismantling the existing DG 2nos and Electrical Panels and other Mechanical & Electrical items etc., work manually/ by mechanical means including stacking of dismantling material as per direction of Engineer-in-charge. ( Exisiting Mechanical & Electrical items including DGs & Panels etc., )

1

-

-

... More
Expand Joint area cleaning,PU sealant applying,Two coat Boscolastic chemical coating

152.7

-

-

... More
Providing and fixing Anodized aluminium partially panelled and partially glazed door with extruded built up standard tubular sections/ appropriate sections of approved make conforming to IS: 733 and IS : 1285, fixed with raw plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, C.P. brass / stainless steel screws, Hinges, Handles, Door stoper & Door closer all complete using 12mm thick Pre-laminated particle board ( both side laminated ) flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, and Float glass panes of 5.50 mm thickness as per architectural drawings and the directions of Engineer-in-charge.

4.8

-

-

... More
Providing and fixing 6mm thick frosted glass fixed window with White colour UPVC casing and all necessary fixtures such as gasket, wool strip, Screws etc. complete as directed and approved by engineer incharge.

73.12

-

-

... More
Dismantling the existing truss roof and roofing sheet work manually/ by mechanical means including stacking of dismantling material as per direction of Engineer-in-charge for buildings having cumulative Plinth area as specified in the quantity. Bidder to quote amount based on their own assessment during site visit prior to submission of Bid.

146.6

-

-

... More
Providing and laying Pigmented granolithic flooring of 52mm thick (which includes base concrete and top wearing coat 12mm thick in 1:6 (1 cement and 6 parts of 6mm down graded aggregate) in panels not more than 20 sqm. in plan with cement concrete M20 grade by using coarse graded aggregate of 6 to 20 mm size, laid monolithic with floor concrete and finished smooth with power trowel including preparation of concrete surface and form work. The screed strips shall be fixed on the base concrete with 6 mm thick solid aluminium or other metals strips for effective separation of panels not exceeding 20 sqm. in plan, unevenness in floor finish shall not exceed +2mm in one square metre area, curing, grouting of lugs, etc. The rate shall include cost of materials, labour, tools & plants, loading and unloading, transportation, scaffolding and all other incidental charges etc., with all leads and lifts, complete as per specifications, drawings and as directed by the Engineer-in-charge

525

-

-

... More
Supplying and laying Mangalore tile type decorative roofing tile over the RCC sloped roof jointed with neat cement slurry mixed with pigment to match the shade of tiles,including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).

350.93

-

-

... More
All cracks area v cutting and cleaning, one coat Hydroment476 chemical primer coating,Elastobar chemical with cementation chemical packing

328

-

-

... More
Providing and laying PVC partitions/Doors  made of 10mm thick PVC shutters of 72 grade with 25mm thick MS frame with necessary accssories as per manufacturers specifications in superstructure above plinth level up to floor V level.  

43.41

-

-

... More
GI sheet area One coat Oil Bitumen primer Applying@ 0.40 litre/sqm,3mm Bitumen felt butane torch applying,all Bitumen joint area heatmeltingang Hot bitumen sealing,final one coat heat resistance silver paint applying

2118.61

-

-

... More
Providing and fixing 16mm dia lokset using appropriate chemical for jointing the structural steel member to the existing RCC member as per the manufacturers instructions including all material manpower tools and tackles etc all complete as required for satisfactory completion.

160

-

-

... More
Supplying & fixing in position Toilet Cubicle of standard dimension which includes 600mm door size width made of heat, bacteria, water, chemical, scratch and impact resistant 12mm thick solid compact laminate panels including doors, pilasters & intermediate panels finished with approved texture / shade as per the details & as per IS 2046 (Indian Standard). This also includes providing and fixing in position necessary hardware made out of aluminum supporting systems (1) Door Knob, (2) Gravity hinges, (3) Latch lock indicators, (4) Top rail, (5) Coat Hooks, (6) U-Channels, (7) Door stopper channel (8) SS Adjustable foot, (9) Noise deafending tape etc., (10) Screws (Stainless steel in 304 grad with satin finish) & wall plugs. The adjustable foot support the pilaster and its based in ancore to the floor with stainless stell & nylon plug fixed in to ground, there U channel are used to attached the divider panels to the wall, the alluminium toprail coated in natural anodized color to used to fix the pilaster at the top. Contractor shall provide 5 years maintenance free guarantee against any moisture related damaged to all panel door & pilasters

16

-

-

... More
Dismantling / removing the existing roofing sheet with wooden truss etc., work manually/ by mechanical means including stacking of dismantling material as per direction of Engineer-in-charge and the new roofing truss as per site conditions for buildings having cumulative Plinth area as specified in the quantity to be designed by the contractor as per the applicable codes and standard. Bidder to quote amount based on their own assessment during site visit prior to submission of Bid.

43.46

-

-

... More
Dismantling and removing air conditioning indoor and outdoor unit along with wires, cables etc. complete and then keeping them in a secured place as per the instruction of the engineer in charge.

10

-

-

... More
Dismantling and removing all kinds of chairs fixed to flooring all complete and keeping them in a secured place as per the instruction of the engineer in charge.

20

-

-

... More
Dismantling and removing acoustic wall pannels and acoustic flooring all complete and keeping them in a secured place as per the instruction of the engineer in charge.

752.81

-

-

... More
Dismantling the existing stage with the height not more than 1 mtr from FFL ( PCC, Brick work & Plastering ) and carting away the compacted earth inside stage and disposing the rubbish and earth as directed by the Engineer in charge.

23.7

-

-

... More
Green fabric of thickness not less than 250 GSM forChroma screen 0% gathering with eyelets. Size: L Mtr x H Mtr. ( Makes: Mayur / Omphile / Raymonds / Nexgen) .

837.85

-

-

... More
RCC walls and Floor area Holes cleaning, Bostic Patch fix micro concrete Chemical and baby chips packing (hole size up to 100mm dia & up to 200 mm depth ) Bidder to quote amount based on their own assessment during site visit prior to submission of Bid.

12

-

-

... More
Brick wall Holes area cleaning ,one coat boscochem 475 chemical primer coating, Micro concrete chemical packing (hole size up to 100mm dia & up to 100 mm depth ) Bidder to quote amount based on their own assessment during site visit prior to submission of Bid.

23

-

-

... More
Treatment for reinforcement exposed in and around the existing buildings, First coat Hydroment476 chemical primer coating 4 Hours curring,After 4 hours Two coat Hydroment476 with cementation .Bidder to quote amount based on their own assessment during site visit prior to submission of Bid.

2069.2

-

-

... More
Part 2. Plumbing works

-

-

-

... More
Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth up to 1.5 m including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth. including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m: Hard rock (requiring blasting) Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia

230

-

-

... More
Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/6 litre (adjustable to 4 litre /8 litres), including seat cover, and cistern fittings, nuts bolts and gasket etc complete. 

54

-

-

... More
Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx.size 610x390x370 mm having pre & post flushing with water ( 250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer - in-charge. 

27

-

-

... More
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required: Kitchen sink with drain board 510x1040 mm bowl depth 250 mm

2

-

-

... More
Providing and fixing mirror of superior glass ( of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 1500x450 mm 

94

-

-

... More
Providing and fixing C.P. brass toilet paper holder: 

81

-

-

... More
Providing and fixing trap of self cleansing design with screwed down or hinged grating without vent arm complete, including cost of cutting and making good the walls and floors: 100 mm inlet and 100 mm outlet - Sand cast iron S & S as per IS : 3989 

142

-

-

... More
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms 

94

-

-

... More
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm. weighing not less than 170 gms

94

-

-

... More
Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/6 litre (adjustable to 4 litre /8 litres), including seat cover, and cistern fittings, nuts bolts and gasket etc complete.

27

-

-

... More
Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx.size 610x390x370 mm having pre & post flushing with water ( 250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer - in-charge.

6

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 20 mm nominal outer dia pipes 

425

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 25 mm nominal outer dia pipes 

510

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 32 mm nominal outer dia pipes 

107

-

-

... More
Providing and fixing brass bib cock of approved quality : 15 mm nominal bore 

63

-

-

... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 32 mm nominal bore 

34

-

-

... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 40 mm nominal bore 

4

-

-

... More
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete: 20 mm nominal bore

29

-

-

... More
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete: 25 mm nominal bore

48

-

-

... More
Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet: 100 mm diameter

24

-

-

... More
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 8931 15 mm nominal bore

2

-

-

... More
Providing and fixing square-mouth S.W. gully trap class SP -1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 

73

-

-

... More
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design: Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weigh of cover 23 kg and weight of frame 15 kg): 

35

-

-

... More
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS: 10910 on 12 mm dia steeel bar conforming to IS:1786, having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 ( 1cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) Complete as per design 

104

-

-

... More
Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge. 

81

-

-

... More
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 40 mm pipe 6Kgf/cm2 

252

-

-

... More
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 6 kgf/cm2 

171

-

-

... More
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 75 mm pipe 6 Kgf/cm2 

427

-

-

... More
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2 

306

-

-

... More
Providing and fixing wash basin with C.I. brackets, sensor pillar cock, 32 mm C.P. brass waste of standard pattern and all necessary accessories, including painting of fittings and brackets, cutting and making good the walls wherever require: 

96

-

-

... More
Supply and fix electrical water heater 25 liter capacity with all necessary accessories complete with all water proofing mounting and fastening material heat insulation, safety and return valves complete with all accessories etc complete as per drawing and as directed by the Engineer-in-charge.

24

-

-

... More
Part 3.Internal firefighting works

-

-

-

... More
Supply, erection, testing and commissioning of heavy C class MS pipes . The pipes being fixed on to the wall or suspended from the ceiling / truss with angle iron supports complete with bends, tees, flanges and with all other required accessories including painting of the pipeline with two coats of approved enamel paint over a coat of primer etc complete - 150mm dia pipe

570

-

-

... More
Supply, erection, testing and commissioning of heavy C class MS pipes . The pipes being fixed on to the wall or suspended from the ceiling / truss with angle iron supports complete with bends, tees, flanges and with all other required accessories including painting of the pipeline with two coats of approved enamel paint over a coat of primer etc complete - 50mm dia drain line

116

-

-

... More
Supply, erect, jointing, testing and commissioning MS Heavy C class in trenches (1 Mtrs below ground level). Rate quoted shall include for necessary specials like long radius bends, tees including cutting, welding, flanged joints with necessary washers, nuts, bolts etc. Rate quoted shall also include for providing concrete anchor blocks at all change in direction of pipeline and also near each joints and giving anticorrosive treatment as per specification. Including cost for excavation & refilling. - 150mm dia pipe

60

-

-

... More
Providing, Laying, Testing and commissioning of 250 mm dia RCC pipes of NP2 class hume pipes

60

-

-

... More
Supply, fixing, testing and commissioning of lever operated slim seal butterfly valves as per detailed specifications complete with Tamper switch, companion flange, nuts, gaskets, bolts etc complete as required - 150mm dia pipe

6

-

-

... More
Supply, fixing, testing and commissioning of Single Hydrant valve (SS)

23

-

-

... More
Supply, fixing, testing and commissioning of RRL hose filled with SS couplings of 15 mtr long

46

-

-

... More
Supply, fixing, testing and commissioning of SS branch pipe

23

-

-

... More
Supply, fixing, testing and commissioning of Hose reel Drum with Hose Reel of 30 mtr and spray nozzle.

23

-

-

... More
Supply, fixing, testing and commissioning of MS Hose Tray MS Hose tray is type of Hose rack. It is fixed inside the fire cabinet/fire duct door.

23

-

-

... More
Supply and fix Internal glass fronted duct Door with hinged and lock, made out of 16 Aluminium powder coated(po red) sheet of suitable size as per specifiaions and drawings

23

-

-

... More
Supply & fixing of Brass air release valve 25mm at the top of each floor of the riser with drain connection and the rates shall include all the accessories.

5

-

-

... More
Supply, erection, testing and commissioning of C class GI pipes . The pipes being fixed on to the wall or suspended from the ceiling / truss with angle iron supports complete with bends, tees, flanges and with all other required accessories including painting of the pipeline with two coats of approved enamel paint over a coat of primer etc complete - 150mm dia

315.5

-

-

... More
Supply, erection, testing and commissioning of C class GI pipes . The pipes being fixed on to the wall or suspended from the ceiling / truss with angle iron supports complete with bends, tees, flanges and with all other required accessories including painting of the pipeline with two coats of approved enamel paint over a coat of primer etc complete - 50mm dia

105

-

-

... More
Supply, erection, testing and commissioning of C class GI pipes . The pipes being fixed on to the wall or suspended from the ceiling / truss with angle iron supports complete with bends, tees, flanges and with all other required accessories including painting of the pipeline with two coats of approved enamel paint over a coat of primer etc complete - 40mm dia

40

-

-

... More
Supply, erection, testing and commissioning of C class GI pipes . The pipes being fixed on to the wall or suspended from the ceiling / truss with angle iron supports complete with bends, tees, flanges and with all other required accessories including painting of the pipeline with two coats of approved enamel paint over a coat of primer etc complete - 32mm dia

40

-

-

... More
Supply, erection, testing and commissioning of C class GI pipes . The pipes being fixed on to the wall or suspended from the ceiling / truss with angle iron supports complete with bends, tees, flanges and with all other required accessories including painting of the pipeline with two coats of approved enamel paint over a coat of primer etc complete - 25mm dia

220

-

-

... More
Supply, fixing, testing and commissioning of lever operated slim seal butterfly valves as per detailed specifications complete with Tamper switch, companion flange, nuts, gaskets, bolts etc complete as required - 100m dia

5

-

-

... More
Supplying, Installing, testing and commissioning of Test & Drain valve of size 50mm.

17

-

-

... More
Supplying, Installing, testing and commissioning of Standard Response Pendent 1/2" BSPT end connection, 68 deg , Celsius, chrome finish.

101

-

-

... More
Supplying, Installing, testing and commissioning of flow switch 150mm dia installed on the sprinkler main distribution line connected to the main sprinkler annunciation panel located in the ground floor.

5

-

-

... More
Supplying, Installing, testing and commissioning of SS ball valve of size 25mm dia for flushing purpose.

15

-

-

... More
Supply, Installation, Testing & Commissioning of 4 Kg Capacity of ABC type fire extinguisher fixing on the floor with suitable fixture.

95

-

-

... More
Supply, Installation, Testing & Commissioning of 4.5 Kg capacity of CO2 type fire extinguisher fixing on the floor with suitable fixture.

98

-

-

... More
Part 4.Acoustic works

-

-

-

... More
Drishya building - VFX ROOM - ACOUSTIC FALSE CEILING - Supply and installation of False ceilings with Compressed polyfibre panel: Polyfibre panels, core-pigmented, high-density, rigid panels of size 1200x2400x9mm, volume density 210 - 230kg/m3, weight 1.9 - 2.1kg/m2 installed by using Strut ceiling framework.The Strut ceiling framework system shall include Strut WC25 Wall channel, fully knurled, sectional thickness 0.55mm, length 3600mm, unequal flanges of 20 & 30mm and web of 25mm, fixed along the perimeters of the wall with nylon sleeves and suitable fasteners at every 300mm centers. Then suspend Strut MC45 Main channels, fully knurled, sectional thickness 0.8mm, length 3600mm, equal flanges of 15mm and web 45mm from the soffit at 1200mm centers with Strut SA25, fully knurled, Suspender angle with sectional thickness 0.55mm, unequal flanges of 25 & 10mm. Strut CC25 Cross channel, fully knurled, sectional thickness 0.55mm, length 3600mm, web 35mm, depth of 20mm and equal flanges 9.5mm is fastened to the Strut MC45 perpendicularly at 600mm centers. panels of size 1200x2400x9mm is installed on the Strut CC25 with suitable fasteners in a staggered manner.Technical Parameters of system Fire (Class) – B, Acoustics – NRC 0.4 (For A mounting), Thermal conductivity (W/mk)– na. Climate (°C, RH) – 50, 99, Light reflectance (%) – Colour Dependant, Green (VoC, RC %) – Nil, 30. Colour to be choosed by client/architect/consultant. Appoved Makes- Anutone/Topakustik /Tranquil/Equivalent

54

-

-

... More
Drishya building - SIDE WALLS ACOUSTIC PANELLING - Supply and installation of Compressed polyfibre panel:, Core-pigmented, high-density, Polyfibre panels rigid panels of size 1200x2400x9mm thk, volume density 210 - 230kg/m3, weight 1.9 - 2.1kg/m2. Prior to installation, ensure wall or surface behind are flat, dry and free from dust or other contaminants and leveled.Panels are then adhered to wall or surface behind with stick S7 adhesive. Technical Parameters of system Fire (Class) – B, Acoustics – NRC 0.4 (For A mounting), Thermal conductivity (W/mk)– na. Climate (°C, RH) – 50, 99, Light reflectance (%) – Colour Dependant, Green (VoC, RC %) – Nil, 30. Colour to be choosed by client/architect/consultant. Appoved Makes- Anutone/Topakustik /Tranquil/Equivalent

70

-

-

... More
Drishya building - WOODEN FLOORING - Supply and installation of Vinyl flooring using 2mm thk Industrial grade Vinyl flooring with Anti -skid ,abrasion resistance , fire proof with hardness. The costing includes 150mm skirting with all accessories. Vinyl floor of approved make and shade as per approved sample by Archtiect & Consultant. Appoved Makes- Armstrong, Gerflor , LG/Equivalent

26

-

-

... More
Drishya Buildig - Edit Suite-1 - ACOUSTIC FALSE CEILING - Supply and installation of False ceilings with Compressed polyfibre panel: Polyfibre panels, core-pigmented, high-density, rigid panels of size 1200x2400x9mm, volume density 210 - 230kg/m3, weight 1.9 - 2.1kg/m2 installed by using Strut ceiling framework.The Strut ceiling framework system shall include Strut WC25 Wall channel, fully knurled, sectional thickness 0.55mm, length 3600mm, unequal flanges of 20 & 30mm and web of 25mm, fixed along the perimeters of the wall with nylon sleeves and suitable fasteners at every 300mm centers. Then suspend Strut MC45 Main channels, fully knurled, sectional thickness 0.8mm, length 3600mm, equal flanges of 15mm and web 45mm from the soffit at 1200mm centers with Strut SA25, fully knurled, Suspender angle with sectional thickness 0.55mm, unequal flanges of 25 & 10mm. Strut CC25 Cross channel, fully knurled, sectional thickness 0.55mm, length 3600mm, web 35mm, depth of 20mm and equal flanges 9.5mm is fastened to the Strut MC45 perpendicularly at 600mm centers. panels of size 1200x2400x9mm is installed on the Strut CC25 with suitable fasteners in a staggered manner.Technical Parameters of system Fire (Class) – B, Acoustics – NRC 0.4 (For A mounting), Thermal conductivity (W/mk)– na. Climate (°C, RH) – 50, 99, Light reflectance (%) – Colour Dependant, Green (VoC, RC %) – Nil, 30. Colour to be choosed by client/architect/consultant.Appoved Makes- Anutone/Topakustik /Tranquil/Equivalent

49

-

-

... More
Drishya Buildig - Edit Suite-1 - SIDE WALLS ACOUSTIC PANELLING - Supply and installation of Compressed polyfibre panel:, Core-pigmented, high-density, Polyfibre panels rigid panels of size 1200x2400x9mm thk, volume density 210 - 230kg/m3, weight 1.9 - 2.1kg/m2. Prior to installation, ensure wall or surface behind are flat, dry and free from dust or other contaminants and leveled.Panels are then adhered to wall or surface behind with stick S7 adhesive. Technical Parameters of system Fire (Class) – B, Acoustics – NRC 0.4 (For A mounting), Thermal conductivity (W/mk)– na. Climate (°C, RH) – 50, 99, Light reflectance (%) – Colour Dependant, Green (VoC, RC %) – Nil, 30. Colour to be choosed by client/architect/consultant. Appoved Makes- Anutone/Topakustik /Tranquil/Equivalent

98

-

-

... More
Drishya Buildig - Edit Suite-1 - WOODEN FLOORING - Supply and installation of Vinyl flooring using 2mm thk Industrial grade Vinyl flooring with Anti -skid ,abrasion resistance , fire proof with hardness. The costing includes 150mm skirting with all accessories. Vinyl floor of approved make and shade as per approved sample by Archtiect & Consultant. Appoved Makes- Armstrong, Gerflor , LG/Equivalent

49

-

-

... More
Drishya building - Edit Suite-2 - ACOUSTIC FALSE CEILING - Supply and installation of False ceilings with Compressed polyfibre panel: Polyfibre panels, core-pigmented, high-density, rigid panels of size 1200x2400x9mm, volume density 210 - 230kg/m3, weight 1.9 - 2.1kg/m2 installed by using Strut ceiling framework.The Strut ceiling framework system shall include Strut WC25 Wall channel, fully knurled, sectional thickness 0.55mm, length 3600mm, unequal flanges of 20 & 30mm and web of 25mm, fixed along the perimeters of the wall with nylon sleeves and suitable fasteners at every 300mm centers. Then suspend Strut MC45 Main channels, fully knurled, sectional thickness 0.8mm, length 3600mm, equal flanges of 15mm and web 45mm from the soffit at 1200mm centers with Strut SA25, fully knurled, Suspender angle with sectional thickness 0.55mm, unequal flanges of 25 & 10mm. Strut CC25 Cross channel, fully knurled, sectional thickness 0.55mm, length 3600mm, web 35mm, depth of 20mm and equal flanges 9.5mm is fastened to the Strut MC45 perpendicularly at 600mm centers. panels of size 1200x2400x9mm is installed on the Strut CC25 with suitable fasteners in a staggered manner.Technical Parameters of system Fire (Class) – B, Acoustics – NRC 0.4 (For A mounting), Thermal conductivity (W/mk)– na. Climate (°C, RH) – 50, 99, Light reflectance (%) – Colour Dependant, Green (VoC, RC %) – Nil, 30. Colour to be choosed by client/architect/consultant.Appoved Makes- Anutone/Topakustik /Tranquil/Equivalent

49

-

-

... More
Drishya building - Edit Suite-2 - SIDE WALLS ACOUSTIC PANELLING - Supply and installation of Compressed polyfibre panel:, Core-pigmented, high-density, Polyfibre panels rigid panels of size 1200x2400x9mm thk, volume density 210 - 230kg/m3, weight 1.9 - 2.1kg/m2. Prior to installation, ensure wall or surface behind are flat, dry and free from dust or other contaminants and leveled.Panels are then adhered to wall or surface behind with stick S7 adhesive. Technical Parameters of system Fire (Class) – B, Acoustics – NRC 0.4 (For A mounting), Thermal conductivity (W/mk)– na. Climate (°C, RH) – 50, 99, Light reflectance (%) – Colour Dependant, Green (VoC, RC %) – Nil, 30. Colour to be choosed by client/architect/consultant. Appoved Makes- Anutone/Topakustik /Tranquil/Equivalent

98

-

-

... More
Drishya building - Edit Suite-2 - WOODEN FLOORING - Supply and installation of Vinyl flooring using 2mm thk Industrial grade Vinyl flooring with Anti -skid, abrasion resistance , fire proof with hardness. Wood Finish, Vinyl flooring of tile size-450mm X 450mm or Roll as per the instruction of Engineer in charge. The costing includes 150mm skirting with all accessories. Vinyl floor of approved make and shade as per approved sample by Engineer in charge. Approved Makes- Armstrong, Gerflor , LG/Equivalent.

49

-

-

... More
Drishya building - Edit Suite-3 - ACOUSTIC FALSE CEILING - Supply and installation of False ceilings with Compressed polyfibre panel: Polyfibre panels, core-pigmented, high-density, rigid panels of size 1200x2400x9mm, volume density 210 - 230kg/m3, weight 1.9 - 2.1kg/m2 installed by using Strut ceiling framework.The Strut ceiling framework system shall include Strut WC25 Wall channel, fully knurled, sectional thickness 0.55mm, length 3600mm, unequal flanges of 20 & 30mm and web of 25mm, fixed along the perimeters of the wall with nylon sleeves and suitable fasteners at every 300mm centers. Then suspend Strut MC45 Main channels, fully knurled, sectional thickness 0.8mm, length 3600mm, equal flanges of 15mm and web 45mm from the soffit at 1200mm centers with Strut SA25, fully knurled, Suspender angle with sectional thickness 0.55mm, unequal flanges of 25 & 10mm. Strut CC25 Cross channel, fully knurled, sectional thickness 0.55mm, length 3600mm, web 35mm, depth of 20mm and equal flanges 9.5mm is fastened to the Strut MC45 perpendicularly at 600mm centers. panels of size 1200x2400x9mm is installed on the Strut CC25 with suitable fasteners in a staggered manner.Technical Parameters of system Fire (Class) – B, Acoustics – NRC 0.4 (For A mounting), Thermal conductivity (W/mk)– na. Climate (°C, RH) – 50, 99, Light reflectance (%) – Colour Dependant, Green (VoC, RC %) – Nil, 30. Colour to be choosed by client/architect/consultant.Appoved Makes- Anutone/Topakustik /Tranquil/Equivalent

17

-

-

... More
Drishya building - Edit Suite-3 - SIDE WALLS ACOUSTIC PANELLING - Supply and installation of Compressed polyfibre panel:, Core-pigmented, high-density, Polyfibre panels rigid panels of size 1200x2400x9mm thk, volume density 210 - 230kg/m3, weight 1.9 - 2.1kg/m2. Prior to installation, ensure wall or surface behind are flat, dry and free from dust or other contaminants and leveled.Panels are then adhered to wall or surface behind with stick S7 adhesive. Technical Parameters of system Fire (Class) – B, Acoustics – NRC 0.4 (For A mounting), Thermal conductivity (W/mk)– na. Climate (°C, RH) – 50, 99, Light reflectance (%) – Colour Dependant, Green (VoC, RC %) – Nil, 30. Colour to be choosed by client/architect/consultant. Appoved Makes- Anutone/Topakustik /Tranquil/Equivalent

58

-

-

... More
Drishya building - Edit Suite-3 - WOODEN FLOORING - Supply and installation of Vinyl flooring using 2mm thk Industrial grade Vinyl flooring with Anti -skid ,abrasion resistance , fire proof with hardness. The costing includes 150mm skirting with all accessories. Vinyl floor of approved make and shade as per approved sample by Archtiect & Consultant. Appoved Makes- Armstrong, Gerflor , LG/Equivalent

17

-

-

... More
Drishya building - Edit Suite-4 - ACOUSTIC FALSE CEILING - Supply and installation of False ceilings with Compressed polyfibre panel: Polyfibre panels, core-pigmented, high-density, rigid panels of size 1200x2400x9mm, volume density 210 - 230kg/m3, weight 1.9 - 2.1kg/m2 installed by using Strut ceiling framework.The Strut ceiling framework system shall include Strut WC25 Wall channel, fully knurled, sectional thickness 0.55mm, length 3600mm, unequal flanges of 20 & 30mm and web of 25mm, fixed along the perimeters of the wall with nylon sleeves and suitable fasteners at every 300mm centers. Then suspend Strut MC45 Main channels, fully knurled, sectional thickness 0.8mm, length 3600mm, equal flanges of 15mm and web 45mm from the soffit at 1200mm centers with Strut SA25, fully knurled, Suspender angle with sectional thickness 0.55mm, unequal flanges of 25 & 10mm. Strut CC25 Cross channel, fully knurled, sectional thickness 0.55mm, length 3600mm, web 35mm, depth of 20mm and equal flanges 9.5mm is fastened to the Strut MC45 perpendicularly at 600mm centers. panels of size 1200x2400x9mm is installed on the Strut CC25 with suitable fasteners in a staggered manner.Technical Parameters of system Fire (Class) – B, Acoustics – NRC 0.4 (For A mounting), Thermal conductivity (W/mk)– na. Climate (°C, RH) – 50, 99, Light reflectance (%) – Colour Dependant, Green (VoC, RC %) – Nil, 30. Colour to be choosed by client/architect/consultant.Appoved Makes- Anutone/Topakustik /Tranquil/Equivalent

12

-

-

... More
- SIDE WALLS ACOUSTIC PANELLING - Supply and installation of Compressed polyfibre panel:, Core-pigmented, high-density, Polyfibre panels rigid panels of size 1200x2400x9mm thk, volume density 210 - 230kg/m3, weight 1.9 - 2.1kg/m2. Prior to installation, ensure wall or surface behind are flat, dry and free from dust or other contaminants and leveled.Panels are then adhered to wall or surface behind with stick S7 adhesive. Technical Parameters of system Fire (Class) – B, Acoustics – NRC 0.4 (For A mounting), Thermal conductivity (W/mk)– na. Climate (°C, RH) – 50, 99, Light reflectance (%) – Colour Dependant, Green (VoC, RC %) – Nil, 30. Colour to be choosed by client/architect/consultant. Appoved Makes- Anutone/Topakustik /Tranquil/Equivalent

40

-

-

... More
Drishya building - Edit Suite-4 - WOODEN FLOORING - Supply and installation of Vinyl flooring using 2mm thk Industrial grade Vinyl flooring with Anti -skid ,abrasion resistance , fire proof with hardness. The costing includes 150mm skirting with all accessories. Vinyl floor of approved make and shade as per approved sample by Archtiect & Consultant. Appoved Makes- Armstrong, Gerflor , LG/Equivalent

12

-

-

... More
DI BUILDING- DI-BASELIGHT 2-FACILITY- 1 - FALSE CEILING - Supply and Installation of Acoustical Ebony square edge, Glassfibre core fully encapsulated ceiling tile of size 595x1195x15mm having density 100-120Kgs/m3, weight 1.5-1.8kg/m2 which is suspended by using 0.3mm thick and 15mm wide pre coated metal T15 grid system.The T15 Grid system of 600x600mm module shall include wall angle (WA15W30) with unequal flanges of size 14&20mm wide, length 3000mm, 0.43mm thick fixed along the perimeter of walls with the help of nylon sleeves and suitable fasteners at 300mm centers. Then suspend the Main T15 (MT15W36) having flange width 15mm, height 32mm and length 3600mm from the soffit with help of soffit cleat and wire rod with leveling spring clip at 1200mm c/c. Cross T15 (CT15W12) having flange width 15mm, height 32mm and length 1200mm is then interlocked into the pre-cut slots in the Main T15 at 600mm centers in the direction perpendicular to the Main T15. Finally Cross T15 (CT15W06) having flange width 15mm, height 32mm and length 600mm are then interlocked into the pre cut slots in the 1200mm Cross T15 at 1200mm centers and in direction parallel to the Main T15. Acoustical Ebony Square edge of size 595x51195x15mm thick shall be placed into the grid size of 600x600mm. Ensure arrow marks behind Acoustical panels are orianted in one direction to achieve uniform shade.Appoved Makes- Anutone/Gyproc/Amstrong/Equivalent

210

-

-

... More
DI BUILDING- DI-BASELIGHT 2-FACILITY- 1 - FALSE CEILING - Supply and installation of Peripheral False ceilings with tufbloc HDFR, square edge, magnesia cement core panels of size 1200x2400x10mm, density 1000kgs/m3, weight 10 kg/m2, installed by using Strut ceiling framework.The Strut ceiling framework system shall include Strut WC25 Wall channel, fully knurled, sectional thickness 0.55mm, length 3600mm, unequal flanges of 20 & 30mm and web of 25mm, fixed along the perimeters of the wall with nylon sleeves and suitable fasteners at every 300mm centers. Then suspend Strut MC45 Main channels, fully knurled, sectional thickness 0.8mm, length 3600mm, equal flanges of 15mm and web 45mm from the soffit at 1200mm centers with Strut SA25, fully knurled, Suspender angle with sectional thickness 0.55mm, unequal flanges of 25 & 10mm. Strut CC25 Cross channel, fully knurled, sectional thickness 0.55mm, length 3600mm, web 35mm, depth of 20mm and equal flanges 9.5mm is fastened to the Strut MC45 perpendicularly at 600mm centers. tufbloc HDFR, 1200x2400x10mm is installed on the Strut CC25 with suitable fasteners in a staggered manner. 4mm gap should be maintained between adjacent tufblocboards on all sides. Appoved Makes- Anutone/Gyproc/Amstrong/Equivalent

54

-

-

... More
DI BUILDING- DI-BASELIGHT 2-FACILITY- 1 -SIDE WALLS ACOUSTIC PANELLING - Supply and installation of Compressed polyfibre panel:, Core-pigmented, high-density, Polyfibre panels rigid panels of size 1200x2400x9mm thk, volume density 210 - 230kg/m3, weight 1.9 - 2.1kg/m2. Prior to installation, ensure wall or surface behind are flat, dry and free from dust or other contaminants and leveled.Panels are then adhered to wall or surface behind with stick S7 adhesive. Technical Parameters of system Fire (Class) – B, Acoustics – NRC 0.4 (For A mounting), Thermal conductivity (W/mk)– na. Climate (°C, RH) – 50, 99, Light reflectance (%) – Colour Dependant, Green (VoC, RC %) – Nil, 30. Colour to be choosed by client/architect/consultant. Appoved Makes- Anutone/Topakustik /Tranquil/Equivalent

480

-

-

... More
Supply and installation of black screen masking fabric of thickness not less than 250 GSM on the metal screen frame structure provided. Bidder to make their own assessment based on the relevant drawings to meet the requirement.

90

-

-

... More
DI BUILDING- DI-BASELIGHT 2-FACILITY- 1 - CARPET FLOORING - Supply and installation of carpet 4mm thick Tile over the specified area with following specification. The floor which recieves the carpet to be thourougly cleaned as per manufacturer's specification. The carpet is to be laid over a bed of manufacturer's approved adhesive spread evenly over the entire floor. The rate shall include cutting, trimming, fixing and clearing away of residual material to a location as directed. The rate shall also include supplying and laying of a protective layer of PVC or HDPE sheet of 50 microns thickness, held together with scotch tape. The laid carpet to be vacuumed after the removal of protective cover/on commissioning. The measurements of carpet will be the actual laid area. Providing & laying carpet tile with following specification: Style: Tile, Construction : Tufted Textured Loop, Fiber Product: 100% Solution Dye PP, Gauge: 39.4/10cm. (1/12), Finish Pile Thickness: 7.49mm +/- 0.5, Production yarn weight: 20 oz, Dye Method: 100% solution Dyed, Primary backing: Action Back,Tuft Bind: As per ASTM Standards,Delamination Strength: As per ASTM Standards,Static Control: As per ASTM Standards,Soil retardant: Protek ,Anti-Microbial:Alphasan Built in Protection, Moisture Control: Yes,Electrostatic propensity: less than 3.5KV-Permanent Cond, Flammability( Radient Panel ASTM-E-662): _0.45 ( Class I)

210

-

-

... More
DI BUILDING- DI-BASELIGHT 2-FACILITY- 1 - ACOUSTIC FIRE RATED DOOR - Supply & Installation for Fire Rate Acoustic Door – CONFORMS TI IS 3614 (PART 2) 1992 BS476 (PART 20 & 22) – Door Size: 1500mm(W) x 2100mm(H) Wall Opening Width (W): 1500mm Wall Opening Height(H): 2100mm Profile Size – Single Rebate: 100*58 Door Thickness: 46mm Infill Material: 25mm with density 1000GSM Frame Sheet Tickness:1.6mm Shutter Sheet Thickness: 1.2mm Finish- PU Paint/ Laminate Door Type: Fire Door with Acoustic Treatment Number of Door Leaf: Single Door Accessories: SS Ball Bearing Butt Hinges, Anchor Fastener, Door Closure with Standard Arm, Dead Lock Both side operated lock & Key, SS D Handle on both sides, Fire rated Glass-200x300mm with panel & tape for glass fixing, Concealed Flush Bolt- 600mm, All tight seal (RM) Door (Drop) Bottom Seal.

3

-

-

... More
DI BUILDING- DI-BASELIGHT 2-FACILITY- 1 - THEATRE CHAIRS - Supply & Installation of Back push recliner chair of center to center 588mm,1100mm height, Plywood (hardwood) with induction heating and high pressure pressed. ABS moulded housing for seat & back cushions,armrest made of PP/PPCP/ABS or semi rigid PU foam. Polyurethane injection moulded flexible foam seat and back density 50 – 55 kg/m3, Fabric to be 100% polyester synthetic fabric with 4 mm polyurethane foam lamination.Fire retardant standard ISO3795, FMVVSS302, Water repellent -Standard -AATCC193. Torsion spring/spring steel IS:4454 1981 Grade III. HRCA/CRCA Sheet metal IS:1079 1994, Electrostatic epoxy powder coating thickness:70 - 80 microns. Seat numbering at side of the chair with LED lights on sides along with aisles. The chairs should be installed to the flooring with the anchor fasteners 12mmx100mm pin type. Fabric colour to customer choice. The chair frame shall be up of mettal or wood as directed engineer in charge

60

-

-

... More
OFFICE BUILDING- DUBBING STUDIO - FALSE CEILING - Supply and Installation of Acoustical square edge, Glassfibre core fully encapsulated ceiling tile of size 595x1195x15mm having density 100-120Kgs/m3, weight 1.5-1.8kg/m2 which is suspended by using 0.3mm thick and 15mm wide pre coated metal T15 grid system.The T15 Grid system of 600x600mm module shall include wall angle (WA15W30) with unequal flanges of size 14&20mm wide, length 3000mm, 0.43mm thick fixed along the perimeter of walls with the help of nylon sleeves and suitable fasteners at 300mm centers. Then suspend the Main T15 (MT15W36) having flange width 15mm, height 32mm and length 3600mm from the soffit with help of soffit cleat and wire rod with leveling spring clip at 1200mm c/c. Cross T15 (CT15W12) having flange width 15mm, height 32mm and length 1200mm is then interlocked into the pre-cut slots in the Main T15 at 600mm centers in the direction perpendicular to the Main T15. Finally Cross T15 (CT15W06) having flange width 15mm, height 32mm and length 600mm are then interlocked into the pre cut slots in the 1200mm Cross T15 at 1200mm centers and in direction parallel to the Main T15. Acoustical Ebony Square edge of size 595x51195x15mm thick shall be placed into the grid size of 600x600mm. Ensure arrow marks behind Acoustical panels are orianted in one direction to achieve uniform shade.Appoved Makes- Anutone/Gyproc/Amstrong/Equivalent

31

-

-

... More
OFFICE BUILDING- DUBBING STUDIO - FALSE CEILING -Supply and installation of Peripheral False ceilings with tufbloc HDFR, square edge, magnesia cement core panels of size 1200x2400x10mm, density 1000kgs/m3, weight 10 kg/m2, installed by using Strut ceiling framework.The Strut ceiling framework system shall include Strut WC25 Wall channel, fully knurled, sectional thickness 0.55mm, length 3600mm, unequal flanges of 20 & 30mm and web of 25mm, fixed along the perimeters of the wall with nylon sleeves and suitable fasteners at every 300mm centers. Then suspend Strut MC45 Main channels, fully knurled, sectional thickness 0.8mm, length 3600mm, equal flanges of 15mm and web 45mm from the soffit at 1200mm centers with Strut SA25, fully knurled, Suspender angle with sectional thickness 0.55mm, unequal flanges of 25 & 10mm. Strut CC25 Cross channel, fully knurled, sectional thickness 0.55mm, length 3600mm, web 35mm, depth of 20mm and equal flanges 9.5mm is fastened to the Strut MC45 perpendicularly at 600mm centers. tufbloc HDFR, 1200x2400x10mm is installed on the Strut CC25 with suitable fasteners in a staggered manner. 4mm gap should be maintained between adjacent tufblocboards on all sides. Appoved Makes- Anutone/Gyproc/Amstrong/Equivalent

24

-

-

... More
OFFICE BUILDING- DUBBING STUDIO - SIDE WALLS ACOUSTIC PANELLING - Supply and installation of Isolation & Absortion treatment: Using Calium Silicate/Cement Core board & Stretch NRC wall fabric system with Magnisite bonded pinewood strand boards: The CC25 cross channel Strut framework fastened to wall with 10mm thick 100x100mm Nitrile/Neophrene rubber pads backed with 12mm plywood/hard wood piece of 100x100mm. The channels should never have any direct contact on the dry wall. 12mm Calcium Silicate board of two layers sandwiched with sound memberane sheet of 3mm is fixed on the frame work .Strand square edge magnesite bonded pinewood fiber panels of size 600x1200x20mm having density 400kg/m3, weight 4kg is fastened on the sandwiched board assembly and backed with micro wadding polywool of 1000gsm and 25mm thickness adhered with 12mm rigid vinyl stretch tracks half wrap/full wrap 15mm (FS15) and Midseam 15mm (FS15), with requisite accessories & tools. FS15 tracks to be installed on wooden base, after applying suitable adhesive on both surfaces for a true and continuous secure grip, and heavy-duty fasteners at 150mm centers on one/both sides of stretch track.Fabric of width 1700mm is then aligned to the stretch tracks by following the fabric thread line or pattern. The fabric is stretched and tucked into the Stretch tracks and secure into the locking jaws so that it will be smooth, free of wrinkles with the tucking tools. Fabric colour & design will be specified by architect/consultant.

128

-

-

... More
OFFICE BUILDING- DUBBING STUDIO - Supply and Installation of Acoustic polyether foam base traps of minimum size of 610x280x280 for corners and 600x600x50mm pyradid base base traps for the ceilings & wall surfaces( Minimum 8 nos of corner and 20 nos for walls & ceiling)

1

-

-

... More
OFFICE BUILDING- DUBBING STUDIO - CARPET FLOORING - Supply and installation of carpet 4mm thick Tile over the specified area with following specification. The floor which recieves the carpet to be thourougly cleaned as per manufacturer's specification. The carpet is to be laid over a bed of manufacturer's approved adhesive spread evenly over the entire floor. The rate shall include cutting, trimming, fixing and clearing away of residual material to a location as directed. The rate shall also include supplying and laying of a protective layer of PVC or HDPE sheet of 50 microns thickness, held together with scotch tape. The laid carpet to be vacuumed after the removal of protective cover/on commissioning. The measurements of carpet will be the actual laid area. Providing & laying carpet tile with following specification: Style: Tile, Construction : Tufted Textured Loop, Fiber Product: 100% Solution Dye PP, Gauge: 39.4/10cm. (1/12), Finish Pile Thickness: 7.49mm +/- 0.5, Production yarn weight: 20 oz, Dye Method: 100% solution Dyed, Primary backing: Action Back,Tuft Bind: As per ASTM Standards,Delamination Strength: As per ASTM Standards,Static Control: As per ASTM Standards,Soil retardant: Protek ,Anti-Microbial:Alphasan Built in Protection, Moisture Control: Yes,Electrostatic propensity: less than 3.5KV-Permanent Cond, Flammability( Radient Panel ASTM-E-662): _0.45 ( Class I)

60

-

-

... More
OFFICE BUILDING- DUBBING STUDIO - DOUBLE GLAZED GLASS PARTITION - Supply and installation of Double glazed units with outer glass 6 mm thick clear toughened glass with 12mm air gap and inner 6mm thick clear toughened glass of Saint Gobin make, made as per standard specifications including providing and fixing 200 micron thick Blast Mitigation Film (including Shatter Resistance capability)

13

-

-

... More
OFFICE BUILDING- DUBBING STUDIO - ACOUSTIC FIRE RATED DOOR - Supply & Installation for Fire Rate Acoustic Door – CONFORMS TI IS 3614 (PART 2) 1992 BS476 (PART 20 & 22) – Door Size: 1200mm(W) x 2400mm(H) Wall Opening Width (W): 1200mm Wall Opening Height(H): 2400mm Profile Size – Single Rebate: 100*58 Door Thickness: 46mm Infill Material: 25mm with density 1000GSM Frame Sheet Tickness:1.6mm Shutter Sheet Thickness: 1.2mm Finish- PU Paint/ Laminate Door Type: Fire Door with Acoustic Treatment Number of Door Leaf: Single Door Accessories: SS Ball Bearing Butt Hinges, Anchor Fastener, Door Closure with Standard Arm, Dead Lock Both side operated lock & Key, SS D Handle on both sides, Fire rated Glass-200x300mm with panel & tape for glass fixing, Concealed Flush Bolt- 600mm, All tight seal (RM) Door (Drop) Bottom Seal.

1

-

-

... More
OFFICE BUILDING- DUBBING -CONSOLE ROOM - FALSE CEILING - Supply and installation of False ceilings with tufbloc HDFR, square edge, magnesia cement core panels of size 1200x2400x10mm, density 1000kgs/m3, weight 10 kg/m2, installed by using Strut ceiling framework.The Strut ceiling framework system shall include Strut WC25 Wall channel, fully knurled, sectional thickness 0.55mm, length 3600mm, unequal flanges of 20 & 30mm and web of 25mm, fixed along the perimeters of the wall with nylon sleeves and suitable fasteners at every 300mm centers. Then suspend Strut MC45 Main channels, fully knurled, sectional thickness 0.8mm, length 3600mm, equal flanges of 15mm and web 45mm from the soffit at 1200mm centers with Strut SA25, fully knurled, Suspender angle with sectional thickness 0.55mm, unequal flanges of 25 & 10mm. Strut CC25 Cross channel, fully knurled, sectional thickness 0.55mm, length 3600mm, web 35mm, depth of 20mm and equal flanges 9.5mm is fastened to the Strut MC45 perpendicularly at 600mm centers. tufbloc HDFR, 1200x2400x10mm is installed on the Strut CC25 with suitable fasteners in a staggered manner. 4mm gap should be maintained between adjacent tufblocboards on all sides. Appoved Makes- Anutone/Gyproc/Amstrong/Equivalent

24

-

-

... More
OFFICE BUILDING- DUBBING -CONSOLE ROOM - SIDE WALLS ACOUSTIC PANELLING - Supply and installation of Isolation & Absortion treatment: Using Calium Silicate/Cement Core board & Stretch NRC wall fabric system with Magnisite bonded pinewood strand boards: The CC25 cross channel Strut framework fastened to wall with 10mm thick 100x100mm Nitrile/Neophrene rubber pads backed with 12mm plywood/hard wood piece of 100x100mm. The channels should never have any direct contact on the dry wall. 12mm Calcium Silicate board of two layers sandwiched with sound memberane sheet of 3mm is fixed on the frame work .Strand square edge magnesite bonded pinewood fiber panels of size 600x1200x20mm having density 400kg/m3, weight 4kg is fastened on the sandwiched board assembly and backed with micro wadding polywool of 1000gsm and 25mm thickness adhered with 12mm rigid vinyl stretch tracks half wrap/full wrap 15mm (FS15) and Midseam 15mm (FS15), with requisite accessories & tools. FS15 tracks to be installed on wooden base, after applying suitable adhesive on both surfaces for a true and continuous secure grip, and heavy-duty fasteners at 150mm centers on one/both sides of stretch track.Fabric of width 1700mm is then aligned to the stretch tracks by following the fabric thread line or pattern. The fabric is stretched and tucked into the Stretch tracks and secure into the locking jaws so that it will be smooth, free of wrinkles with the tucking tools. Fabric colour & design will be specified by architect/consultant.

60

-

-

... More
OFFICE BUILDING- DUBBING -CONSOLE ROOM - Supply and Installation of Acoustic Soak Cord, square edge, fabric wrapped pinewood fiber core panel of size 600x1200x25 / 600X600X25 mm,with ribbed finish, volume density 400Kgs/m3, weight 10kg/m2 installed by using Strut Z bar. Strut Z bars having 40mm height, thickness 1mm is first fixed behind the panels by using suitable fasteners. Another length of Strut Z bars to be fastened perpendicular to wall. Soak cord, square edge panels are then slided on to Strut Z bar to fix on the wall surface. Technical Parameter Fire (Class) – 1 & P Acoustics – NRC 0.9 Thermal conductivity (W/mk)– 0.08, Climate (°C, RH) – 50, 90, Light reflectance (%) – colour dependant,Green (VOC, RC %) – Low, 30.Appoved Makes- Anutone/Gyproc/Amstrong/Equivalent

15

-

-

... More
OFFICE BUILDING- DUBBING -CONSOLE ROOM - Supply and Installation of Acoustic polyether foam base traps of minimum size of 610x280x280 for corners and 600x600x50mm pyradid base base traps for the ceilings & wall surfaces( Minimum 8 nos of corner and 20 nos for walls & ceiling)

1

-

-

... More
OFFICE BUILDING- DUBBING -CONSOLE ROOM - WOODEN FLOORING - Supplying, fitting and fixing 8mm thick Laminated wooden Flooring Work conforming to EN13329:2006 with plank size not Iess than 1200 mm X 190 mm (with unilin/tongue-groove locking arrangement) having 0.2mm thk top abrasive layer over a decorative layer followed by a High-density fibreboard (HDF) having density 850 kg/m3 substrate core over a rasin saturated backing layer and installing through unilin or tongue- groove system (having locking strength not less than 1000 kg/m) over a 2 mm thk underlayer polyurethene foam on polythene sheet 250 micron, over a smooth, flat, hard subfloor free from moisture ( 8%), grease etc. complete in all respect with requisite accessories like end profile, transition profile, reducer 'T' profile etc. Cost of Laminate Floor Accessories only (Skirting ,End edge, T- moulding,Reducer) shall have to be added separately, wherever required. (Type and design to ce confirmed by Consultant/ Architect/ Client)

35

-

-

... More
OFFICE BUILDING- DUBBING -CONSOLE ROOM - ACOUSTIC FIRE RATED DOOR - Supply & Installation for Fire Rate Acoustic Door – CONFORMS TI IS 3614 (PART 2) 1992 BS476 (PART 20 & 22) – Door Size: 1200mm(W) x 2400mm(H) Wall Opening Width (W): 1200mm Wall Opening Height(H): 2400mm Profile Size – Single Rebate: 100*58 Door Thickness: 46mm Infill Material: 25mm with density 1000GSM Frame Sheet Tickness:1.6mm Shutter Sheet Thickness: 1.2mm Finish- PU Paint/ Laminate Door Type: Fire Door with Acoustic Treatment Number of Door Leaf: Single Door Accessories: SS Ball Bearing Butt Hinges, Anchor Fastener, Door Closure with Standard Arm, Dead Lock Both side operated lock & Key, SS D Handle on both sides, Fire rated Glass-200x300mm with panel & tape for glass fixing, Concealed Flush Bolt- 600mm, All tight seal (RM) Door (Drop) Bottom Seal.

1

-

-

... More
OFFICE BUILDING- FOLEY STUDIO - FALSE CEILING - Supply and installation of Peripheral False ceilings with tufbloc HDFR, square edge, magnesia cement core panels of size 1200x2400x10mm, density 1000kgs/m3, weight 10 kg/m2, installed by using Strut ceiling framework.The Strut ceiling framework system shall include Strut WC25 Wall channel, fully knurled, sectional thickness 0.55mm, length 3600mm, unequal flanges of 20 & 30mm and web of 25mm, fixed along the perimeters of the wall with nylon sleeves and suitable fasteners at every 300mm centers. Then suspend Strut MC45 Main channels, fully knurled, sectional thickness 0.8mm, length 3600mm, equal flanges of 15mm and web 45mm from the soffit at 1200mm centers with Strut SA25, fully knurled, Suspender angle with sectional thickness 0.55mm, unequal flanges of 25 & 10mm. Strut CC25 Cross channel, fully knurled, sectional thickness 0.55mm, length 3600mm, web 35mm, depth of 20mm and equal flanges 9.5mm is fastened to the Strut MC45 perpendicularly at 600mm centers. tufbloc HDFR, 1200x2400x10mm is installed on the Strut CC25 with suitable fasteners in a staggered manner. 4mm gap should be maintained between adjacent tufblocboards on all sides. Appoved Makes- Anutone/Gyproc/Amstrong/Equivalent

24

-

-

... More
OFFICE BUILDING- FOLEY STUDIO - SIDE WALLS ACOUSTIC PANELLING - Supply and installation of Isolation & Absortion treatment: Using Calium Silicate/Cement Core board & Stretch NRC wall fabric system with Magnisite bonded pinewood strand boards: The CC25 cross channel Strut framework fastened to wall with 10mm thick 100x100mm Nitrile/Neophrene rubber pads backed with 12mm plywood/hard wood piece of 100x100mm. The channels should never have any direct contact on the dry wall. 12mm Calcium Silicate board of two layers sandwiched with sound memberane sheet of 3mm is fixed on the frame work .Strand square edge magnesite bonded pinewood fiber panels of size 600x1200x20mm having density 400kg/m3, weight 4kg is fastened on the sandwiched board assembly and backed with micro wadding polywool of 1000gsm and 25mm thickness adhered with 12mm rigid vinyl stretch tracks half wrap/full wrap 15mm (FS15) and Midseam 15mm (FS15), with requisite accessories & tools. FS15 tracks to be installed on wooden base, after applying suitable adhesive on both surfaces for a true and continuous secure grip, and heavy-duty fasteners at 150mm centers on one/both sides of stretch track.Fabric of width 1700mm is then aligned to the stretch tracks by following the fabric thread line or pattern. The fabric is stretched and tucked into the Stretch tracks and secure into the locking jaws so that it will be smooth, free of wrinkles with the tucking tools. Fabric colour & design will be specified by architect/consultant.

120

-

-

... More
OFFICE BUILDING- FOLEY STUDIO - Supply and Installation of Acoustic Soak Cord, square edge, fabric wrapped pinewood fiber core panel of size 600x1200x25 / 600X600X25 mm,with ribbed finish, volume density 400Kgs/m3, weight 10kg/m2 installed by using Strut Z bar. Strut Z bars having 40mm height, thickness 1mm is first fixed behind the panels by using suitable fasteners. Another length of Strut Z bars to be fastened perpendicular to wall. Soak cord, square edge panels are then slided on to Strut Z bar to fix on the wall surface. Technical Parameter Fire (Class) – 1 & P Acoustics – NRC 0.9 Thermal conductivity (W/mk)– 0.08, Climate (°C, RH) – 50, 90, Light reflectance (%) – colour dependant,Green (VOC, RC %) – Low, 30.Appoved Makes- Anutone/Gyproc/Amstrong/Equivalent

15

-

-

... More
OFFICE BUILDING- FOLEY STUDIO - Supply and Installation of Acoustic polyether foam base traps of minimum size of 610x280x280 for corners and 600x600x50mm pyradid base base traps for the ceilings & wall surfaces( Minimum 8 nos of corner and 20 nos for walls & ceiling)

1

-

-

... More
OFFICE BUILDING- FOLEY STUDIO - VINYL FLOORING - Supply and installation of Vinyl flooring using 2mm thk Industrial grade Vinyl flooring with Anti -skid ,abrasion resistance , fire proof with hardness. The costing includes 150mm skirting with all accessories. Vinyl floor of approved make and shade as per approved sample by Archtiect & Consultant. Appoved Makes- Armstrong, Gerflor , LG/Equivalent

26

-

-

... More
OFFICE BUILDING- FOLEY STUDIO - MULTI MATERIAL FLOORING - Supply and installation of multi flooring materials such us tile, carpet, wooden, stone, concrete, wooden plank, granite, marble, water tub, sand floor etc as per drawing and design specified for the multipurpose of foley studio.

1

-

-

... More
OFFICE BUILDING- FOLEY STUDIO - DOUBLE GLAZED GLASS PARTITION - Supply and installation of Double glazed units with outer glass 6 mm thick clear toughened glass with 12mm air gap and inner 6mm thick clear toughened glass of Saint Gobin make, made as per standard specifications including providing and fixing 200 micron thick Blast Mitigation Film (including Shatter Resistance capability)

13

-

-

... More
OFFICE BUILDING- FOLEY STUDIO -ACOUSTIC FIRE RATED DOOR - Supply & Installation for Fire Rate Acoustic Door – CONFORMS TI IS 3614 (PART 2) 1992 BS476 (PART 20 & 22) – Door Size: 2200mm(W) x 2400mm(H) Wall Opening Width (W): 2200mm Wall Opening Height(H): 2400mm Profile Size – Single Rebate: 100*58 Door Thickness: 46mm Infill Material: 25mm with density 1000GSM Frame Sheet Tickness:1.6mm Shutter Sheet Thickness: 1.2mm Finish- PU Paint/ Laminate Door Type: Fire Door with Acoustic Treatment Number of Door Leaf: Double Door Accessories: SS Ball Bearing Butt Hinges, Anchor Fastener, Door Closure with Standard Arm, Dead Lock Both side operated lock & Key, SS D Handle on both sides, Fire rated Glass-200x300mm with panel & tape for glass fixing, Concealed Flush Bolt- 600mm, All tight seal (RM) Door (Drop) Bottom Seal.

1

-

-

... More
OFFICE BUILDING- FOLEY STUDIO - ACOUSTIC FIRE RATED DOOR - Supply & Installation for Fire Rate Acoustic Door – CONFORMS TI IS 3614 (PART 2) 1992 BS476 (PART 20 & 22) – Door Size: 1200mm(W) x 2400mm(H) Wall Opening Width (W): 1200mm Wall Opening Height(H): 2400mm Profile Size – Single Rebate: 100*58 Door Thickness: 46mm Infill Material: 25mm with density 1000GSM Frame Sheet Tickness:1.6mm Shutter Sheet Thickness: 1.2mm Finish- PU Paint/ Laminate Door Type: Fire Door with Acoustic Treatment Number of Door Leaf: Single Door Accessories: SS Ball Bearing Butt Hinges, Anchor Fastener, Door Closure with Standard Arm, Dead Lock Both side operated lock & Key, SS D Handle on both sides, Fire rated Glass-200x300mm with panel & tape for glass fixing, Concealed Flush Bolt- 600mm, All tight seal (RM) Door (Drop) Bottom Seal.

1

-

-

... More
OFFICE BUILDING- FOLEY STUDIO - FLOATING PROPERTIES FOR FOLEY ROOM - Supply and installation of loose furnitures like table, chair, storage cabinet, cupboards and other loose properties ( Bidder to make own assessment and contractor should prepare furniture layout plan based on the client requirement and submit the same to the Engineer in charge for approval )

1

-

-

... More
OFFICE BUILDING- FOLEY -CONSOLE ROOM - FALSE CEILING - Supply and installation of False ceilings with tufbloc HDFR, square edge, magnesia cement core panels of size 1200x2400x10mm, density 1000kgs/m3, weight 10 kg/m2, installed by using Strut ceiling framework.The Strut ceiling framework system shall include Strut WC25 Wall channel, fully knurled, sectional thickness 0.55mm, length 3600mm, unequal flanges of 20 & 30mm and web of 25mm, fixed along the perimeters of the wall with nylon sleeves and suitable fasteners at every 300mm centers. Then suspend Strut MC45 Main channels, fully knurled, sectional thickness 0.8mm, length 3600mm, equal flanges of 15mm and web 45mm from the soffit at 1200mm centers with Strut SA25, fully knurled, Suspender angle with sectional thickness 0.55mm, unequal flanges of 25 & 10mm. Strut CC25 Cross channel, fully knurled, sectional thickness 0.55mm, length 3600mm, web 35mm, depth of 20mm and equal flanges 9.5mm is fastened to the Strut MC45 perpendicularly at 600mm centers. tufbloc HDFR, 1200x2400x10mm is installed on the Strut CC25 with suitable fasteners in a staggered manner. 4mm gap should be maintained between adjacent tufblocboards on all sides. Appoved Makes- Anutone/Gyproc/Amstrong/Equivalent

20

-

-

... More
OFFICE BUILDING- FOLEY -CONSOLE ROOM - SIDE WALLS ACOUSTIC PANELLING - Supply and installation of Isolation & Absortion treatment: Using Calium Silicate/Cement Core board & Stretch NRC wall fabric system with Magnisite bonded pinewood strand boards: The CC25 cross channel Strut framework fastened to wall with 10mm thick 100x100mm Nitrile/Neophrene rubber pads backed with 12mm plywood/hard wood piece of 100x100mm. The channels should never have any direct contact on the dry wall. 12mm Calcium Silicate board of two layers sandwiched with sound memberane sheet of 3mm is fixed on the frame work .Strand square edge magnesite bonded pinewood fiber panels of size 600x1200x20mm having density 400kg/m3, weight 4kg is fastened on the sandwiched board assembly and backed with micro wadding polywool of 1000gsm and 25mm thickness adhered with 12mm rigid vinyl stretch tracks half wrap/full wrap 15mm (FS15) and Midseam 15mm (FS15), with requisite accessories & tools. FS15 tracks to be installed on wooden base, after applying suitable adhesive on both surfaces for a true and continuous secure grip, and heavy-duty fasteners at 150mm centers on one/both sides of stretch track.Fabric of width 1700mm is then aligned to the stretch tracks by following the fabric thread line or pattern. The fabric is stretched and tucked into the Stretch tracks and secure into the locking jaws so that it will be smooth, free of wrinkles with the tucking tools. Fabric colour & design will be specified by architect/consultant.

60

-

-

... More
OFFICE BUILDING- FOLEY -CONSOLE ROOM - Supply and Installation of Acoustic Soak Cord, square edge, fabric wrapped pinewood fiber core panel of size 600x1200x25 / 600X600X25 mm,with ribbed finish, volume density 400Kgs/m3, weight 10kg/m2 installed by using Strut Z bar. Strut Z bars having 40mm height, thickness 1mm is first fixed behind the panels by using suitable fasteners. Another length of Strut Z bars to be fastened perpendicular to wall. Soak cord, square edge panels are then slided on to Strut Z bar to fix on the wall surface. Technical Parameter Fire (Class) – 1 & P Acoustics – NRC 0.9 Thermal conductivity (W/mk)– 0.08, Climate (°C, RH) – 50, 90, Light reflectance (%) – colour dependant,Green (VOC, RC %) – Low, 30.Appoved Makes- Anutone/Gyproc/Amstrong/Equivalent

18

-

-

... More
OFFICE BUILDING- FOLEY -CONSOLE ROOM - Supply and Installation of Acoustic polyether foam base traps of minimum size of 610x280x280 for corners and 600x600x50mm pyradid base base traps for the ceilings & wall surfaces( Minimum 8 nos of corner and 20 nos for walls & ceiling)

1

-

-

... More
OFFICE BUILDING- FOLEY -CONSOLE ROOM -WOODEN FLOORING - Supplying, fitting and fixing 8mm thick Laminated wooden Flooring Work conforming to EN13329:2006 with plank size not Iess than 1200 mm X 190 mm (with unilin/tongue-groove locking arrangement) having 0.2mm thk top abrasive layer over a decorative layer followed by a High-density fibreboard (HDF) having density 850 kg/m3 substrate core over a rasin saturated backing layer and installing through unilin or tongue- groove system (having locking strength not less than 1000 kg/m) over a 2 mm thk underlayer polyurethene foam on polythene sheet 250 micron, over a smooth, flat, hard subfloor free from moisture ( 8%), grease etc. complete in all respect with requisite accessories like end profile, transition profile, reducer 'T' profile etc. Cost of Laminate Floor Accessories only (Skirting ,End edge, T- moulding,Reducer) shall have to be added separately, wherever required. (Type and design to ce confirmed by Consultant/ Architect/ Client)

20

-

-

... More
OFFICE BUILDING- DUBBING STUDIO - ACOUSTIC FIRE RATED DOOR - Supply, Installation, testing & commissioning for Fire Rate Acoustic Door – CONFORMS TI IS 3614 (PART 2) 1992 BS476 (PART 20 & 22) – Door Size: 1200mm(W) x 2400mm(H) Wall Opening Width (W): 1200mm Wall Opening Height(H): 2400mm Profile Size – Single Rebate: 100*58 Door Thickness: 46mm Infill Material: 50mm PolyWool of 1000GSM density Frame Sheet Tickness:1.6mm Shutter Sheet Thickness: 1.2mm Finish- PU Paint/ Laminate Door Type: Fire Door with Acoustic Treatment Number of Door Leaf: Single Door Accessories: SS Ball Bearing Butt Hinges, Anchor Fastener, Door Closure with Standard Arm, Dead Lock Both side operated lock & Key, SS D Handle on both sides, Fire rated Glass-200x300mm with panel & tape for glass fixing, Concealed Flush Bolt- 600mm, All tight seal (RM) Door (Drop) Bottom Seal.

1

-

-

... More
Part 5.HVAC works

-

-

-

... More
DRISHYA BUILDING - SITC , Unloading, leading, positioning of 2.0 TR Four way casette type Unit Split Air Conditioner with rotary compressor or to Suit for (Camera Lens Storage Room). Unit shall be supplied along with remoe control .(Inverter type units Preferred) having an out door unit with suitable condenser fan as per OEM recommendation along with min 3 meters length of soft copper pipe which normally comes along with the machine . Cassette Type / High wall split unit shall also have a drain pump fitted to it as required. Copper pipe insulation shall also be covered in the cost of the units. Support required for IDU and ODU including Stabilizer (Minimum Double Booster) shall be considered in the unit price. The cost is inclusive of Communication cable between IDU to ODU.

2

-

-

... More
Copper Pipe for Both Suction and Liquid line along with insulation as per piping specs - Unit 1

12

-

-

... More
Copper Pipe for both Suction and Liquid line along with insulation as per piping specs -Unit 2

12

-

-

... More
SITC , Unloading, leading, positioning 1.0 TR Four way casette type IDU for (Store manager Room).Unit shall be considered with Grills, and with drain pump etc as required for complete installation including necessary supporting arrangement etc.

1

-

-

... More
SITC , Unloading, leading, positioning 1.5 TR Four way casette type IDU for (Construction Wing).Unit shall be considered with Grills, and with drain pump etc as required for complete installation including necessary supporting arrangement etc.

1

-

-

... More
SITC , Unloading, leading, positioning 2.0 TR Four Way Cassette type Unit IDU for (Lobby).Unit shall be considered with Grills, and with drain pump etc as required for complete installation including necessary supporting arrangement etc.

4

-

-

... More
SITC , Unloading, leading, positioning 2.0 TR Four way casette type IDU for (AAO Room).Unit shall be considered with Grills, and with drain pump etc as required for complete installation including necessary supporting arrangement etc.

1

-

-

... More
SITC , Unloading, leading, positioning 1.5 TR Four way casette type IDU for Library.Unit shall be considered with Grills, and with drain pump etc as required for complete installation including necessary supporting arrangement etc.

2

-

-

... More
SITC , Unloading, leading, positioning 2.0 TR Four way casette type IDU for Electronic Store.Unit shall be considered with Grills, and with drain pump etc as required for complete installation including necessary supporting arrangement etc.

1

-

-

... More
SITC , Unloading, leading, positioning 3.0 TR Four way casette type IDU for Accounts Office.Unit shall be considered with Grills, and with drain pump etc as required for complete installation including necessary supporting arrangement etc.

2

-

-

... More
SITC , Unloading, leading, positioning 2.0 TR Four way casette type IDU for Admin Office.Unit shall be considered with Grills, and with drain pump etc as required for complete installation including necessary supporting arrangement etc.

2

-

-

... More
SITC,Unloading, leading, positioning 16 HP Min Capacity Variable Refrigerant Flow Outdoor unit (Combined Circuit Totaling to 32 HP) with compressor (Variable speed, Scroll), Air cooled condenser, fan motor, vibration isolation pads etc to be considered. (Basement). Unit with lower power consumption at full load / Part load will be prefferred. All compressors shall be of full inverter type

2

-

-

... More
Supply of Interconnecting cable (Power & Control) from Outdoor to Indoor as required by the OEM for VRF

220

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish. The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between outdoor unit & indoor units. - Pipe Line Size - 5/8"

130

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish. The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between outdoor unit & indoor units. -Pipe Line Size - 3/8"

160

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish. The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between outdoor unit & indoor units. - Pipe Line Size - 1/2"

40

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish. The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between outdoor unit & indoor units - Pipe Line Size - 1/4"

20

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish. The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between outdoor unit & indoor units. Pipe Line Size - 3/4"

40

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish. The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between outdoor unit & indoor units - Pipe Line Size - 1 1/8"

40

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish. The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between outdoor unit & indoor units - Pipe Line Size - 1 3/8"

25

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish. The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between outdoor unit & indoor units- Pipe Line Size - 7/8"

2

-

-

... More
SITC of Refrigerant Gas.

40

-

-

... More
SITC of condensate drain piping out of UPVC pipe with necessary insulation, fittings, U trap as required of size from the indoor unit up to the nearest drain point (Overall Measurement is indicated) Drain pipes carrying Condensate water shall be insulated with min 6mm thick elastomeric Nitrile rubber or as required to avoid sweating. For proper drainage of condensate and to avoid any fouling smell, U trap shall be provided in drain piping wherever required. Size of pipe shall be with in 50 mm to 100 mm or as required at site

120

-

-

... More
Supply of Remote control for each units

14

-

-

... More
Supply of Refnet Joints

14

-

-

... More
Supply of Fresh Air Filter

1.5

-

-

... More
SITC of 50 mm round duct / Rectangular as required with required support/ required insulation thicknes of min 25 mm nitrile rubber / connecting to each units etc as required

30

-

-

... More
SITC of 75 mm round duct / Rectangular as required with required support/ required insulation thicknes of min 25 mm nitrile rubber / connecting to each units etc as required

35

-

-

... More
SITC of 100 mm round duct / Rectangular as required with required support/ required insulation thicknes of min 25 mm nitrile rubber / connecting to each units etc as required

50

-

-

... More
Supply Air Fan with min static of 15 -20 mm or to suit actual site condition including filter and necessary louvers / cowls shall be provided to avoid rain water entry (950 Cfm) Electrical Panel Room

1

-

-

... More
Exhaust Air Fan with min static of 10 mm or to suit actual site condition including necessary louvers / cowls shall be provided to avoid rain water entry (700 cfm) - Electrical Panel Room

2

-

-

... More
Exhaust Air Fan with min static of 10 mm or to suit actual site condition including necessary louvers / cowls shall be provided to avoid rain water entry (350 cfm) - Spare room

1

-

-

... More
Supply Air Fan with min static of 15 -20 mm or to suit actual site condition including filter and necessary louvers / cowls shall be provided to avoid rain water entry (500 Cfm) Temperature Holding Area

1

-

-

... More
Exhaust Air Fan with min static of 10 mm or to suit actual site condition including necessary louvers / cowls shall be provided to avoid rain water entry (600 cfm) - Temperature Holding Area

1

-

-

... More
Supply Air Fan with min static of 15 -20 mm or to suit actual site condition including filter and necessary louvers / cowls shall be provided to avoid rain water entry (500 Cfm) Light Ancillary Area

1

-

-

... More
Exhaust Air Fan with min static of 10 mm or to suit actual site condition including necessary louvers / cowls shall be provided to avoid rain water entry (350 cfm) - Light and Ancillary Area

2

-

-

... More
Supply Air Fan with min static of 15 -20 mm or to suit actual site condition including filter and necessary louvers / cowls shall be provided to avoid rain water entry (800 Cfm) - Rental Dispatch Area

1

-

-

... More
Exhaust Air Fan with min static of 10 mm or to suit actual site condition including necessary louvers / cowls shall be provided to avoid rain water entry (950 cfm) - Rental Dispatch Area

1

-

-

... More
Exhaust Air Fan with min static of 10 mm or to suit actual site condition including necessary louvers / cowls shall be provided to avoid rain water entry (700 cfm) - Receiving Area

1

-

-

... More
Exhaust Air Fan with min static of 15 mm or to suit actual site condition including necessary louvers / cowls shall be provided to avoid rain water entry (1700 cfm) - Central Store Area ( Inline High Static Low Noice Fan)

1

-

-

... More
Supply Air Fan with min static of 15 -20 mm or to suit actual site condition including filter and necessary louvers / cowls shall be provided to avoid rain water entry (600 Cfm) - Central Store Area

2

-

-

... More
Supply of 24G G.I Sheet (Upto 750mm) for GI ducting for fresh air

30

-

-

... More
Supply of Canvas Connection for the inlet and outlet of Exhaust Fan For Central Store Area

2

-

-

... More
Supply of Grill Horizontal For Central Store Area

1

-

-

... More
SITC , Unloading, leading, positioning 8.5 TR Ductable Split Unit circuit with air cooled outdoor unit SCROLL compressor (Inverter compressor can also be considered based on OEM availability), having suitable condenser fan / or as per OEM recommendation and separate isolators to be provided for each unit towards maintenance purpose . The Unit shall have all interconnecting communication cables so as to have effective communication between IDU & with ODU. The price quoted shall be inclusive of IDU and ODU with necessary supporting arrangements for the units indoor and outdoor as required at site

2

-

-

... More
Supply of Communication Cable between IDU and Outdoor unit to suit

40

-

-

... More
SITC , Unloading, leading, positioning 3.0 TR Four way casette type IDU for (Camera Room 1).Unit shall be considered with Grills, and with drain pump etc as required for complete installation including necessary supporting arrangement etc.

1

-

-

... More
SITC , Unloading, leading, positioning 3.0 TR Four way casette type IDU for (Camera Room 2)- Unit shall be considered with Grills, and with drain pump etc as required for complete installation including necessary supporting arrangement etc.

1

-

-

... More
SITC , Unloading, leading, positioning 4 TR Four way casette type IDU for (Equipment Store)- Unit shall be considered with Grills, and with drain pump etc as required for complete installation including necessary supporting arrangement etc.

1

-

-

... More
SITC , Unloading, leading, positioning 2 TR Four way casette type IDU for (AC Customer Lobby) - Unit shall be considered with Grills, and with drain pump etc as required for complete installation including necessary supporting arrangement etc.

1

-

-

... More
SITC , Unloading, leading, positioning 3 TR Four way casette type IDU for (Shooting Lobby) - Unit shall be considered with Grills, and with drain pump etc as required for complete installation including necessary supporting arrangement etc.

1

-

-

... More
SITC , Unloading, leading, positioning 2 TR Four way casette type IDU for (Documentry Section)- Unit shall be considered with Grills, and with drain pump etc as required for complete installation including necessary supporting arrangement etc.

3

-

-

... More
SITC , Unloading, leading, positioning 1.5TR Four way casette type IDU for (VIP room) - Unit shall be considered with Grills, and with drain pump etc as required for complete installation including necessary supporting arrangement etc.

1

-

-

... More
SITC , Unloading, leading, positioning 2.0 TR Four way casette type IDU for (Mini Theatre) - Unit shall be considered with Grills, and with drain pump etc as required for complete installation including necessary supporting arrangement etc.

2

-

-

... More
SITC,Unloading, leading, positioning 28 HP Min Capacity Variable Refrigerant Flow Outdoor unit (Combined Circuit) with compressor (Variable speed, Scroll), Air cooled condenser, fan motor, vibration isolation pads etc to be considered. (Basement). Unit with lower power consumption at full load / Part load will be prefferred. All compressors shall be of full inverter type.

1

-

-

... More
Supply of Interconnecting cable (Power & Control) from Outdoor to Indoor as required by the OEM for VRF

175

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish. The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between outdoor unit & indoor units - Pipe Line Size - 5/8"

90

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish. The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between outdoor unit & indoor units - Pipe Line Size - 3/8"

105

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish. The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between outdoor unit & indoor units - Pipe Line Size - 1/2"

30

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish. The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between outdoor unit & indoor units - Pipe Line Size - 1/4"

10

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish. The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between outdoor unit & indoor units - Pipe Line Size - 3/4"

50

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish. The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between outdoor unit & indoor units - Pipe Line Size - 1 1/8"

30

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish. The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between outdoor unit & indoor units - Pipe Line Size - 1 3/8"

35

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish. The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between outdoor unit & indoor units - Pipe Line Size - 7/8"

2

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish. The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between outdoor unit & indoor units - Suction Line - 1 1/8"

8

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish. The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between outdoor unit & indoor units - Liquid Line - 5/8"

8

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish. The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between outdoor unit & indoor units - Suction Line - 1 1/8"

20

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish. The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between outdoor unit & indoor units - Liquid Line - 5/8"

20

-

-

... More
SITC of Refrigerant Gas - VRF

30

-

-

... More
SITC of Refrigerant Gas - Ductable Unit

20

-

-

... More
SITC of condensate drain piping out of UPVC pipe with necessary insulation, fittings, U trap as required of size from the indoor unit up to the nearest drain point (Overall Measurement is indicated) Drain pipes carrying Condensate water shall be insulated with min 6mm thick elastomeric Nitrile rubber or as required to avoid sweating. For proper drainage of condensate and to avoid any fouling smell, U trap shall be provided in drain piping wherever required. Size of pipe shall be with in 50 mm to 100 mm or as required at site

90

-

-

... More
Supply of Remote control for each units

11

-

-

... More
Supply of Refnet Joints

10

-

-

... More
SITC of Rectangle duct with necessary fittings and supporting arrangements. All ducts used shall be of factory fabricated type only . Any minor connection work at site will have to be carried out with the prior approval of consultant / Client only. The GI Sheets used shall be of Min 120 GSM of Zinc coating and a necessary test certificate as required shall be submitted to client approval. - 24G G.I Sheet (Upto 750mm)

120

-

-

... More
SITC of Rectangle duct with necessary fittings and supporting arrangements. All ducts used shall be of factory fabricated type only . Any minor connection work at site will have to be carried out with the prior approval of consultant / Client only. The GI Sheets used shall be of Min 120 GSM of Zinc coating and a necessary test certificate as required shall be submitted to client approval - 22G G.I Sheet (from 751 - 1500 mm)

15

-

-

... More
SITC of Rectangle duct with necessary fittings and supporting arrangements. All ducts used shall be of factory fabricated type only . Any minor connection work at site will have to be carried out with the prior approval of consultant / Client only. The GI Sheets used shall be of Min 120 GSM of Zinc coating and a necessary test certificate as required shall be submitted to client approval - 20G G.I Sheet (From 1501 - 2250mm)

10

-

-

... More
SITC of Canvas (Fire retardent) along with Damper for supply air for all the units Size - To suit

2

-

-

... More
SITC of VCD (Volume Control Damper)- with Multi Opposed Blade type & frame shall be with Galvanized Iron with min thickness of 18 gauge of frame and min 20 G thick blade shall be used.

2

-

-

... More
SITC of Fresh air damper with pre filter to suit

2

-

-

... More
SITC of Fire Damper with Fusible link to suit the return air (Fire dampers shall be with at least 1.5 hours fire rating. Damper blades shall be one piece folded construction manufactured from high strength galvanized steel Opposed blade type. Damper frames shall be of 18 gauge GI and the blades of min 20 gauge GI).

0.5

-

-

... More
The supply and return air grills / diffusers shall be anodized aluminium construction, square or rectangular in type. Supply air grill / diffusers shall be provided with Al Blade material multi Opposed dampers in all the supply air collars - Air Grill with Damper

6

-

-

... More
The supply and return air grills / diffusers shall be anodized aluminium construction, square or rectangular in type. Supply air grill / diffusers shall be provided with Al Blade material multi Opposed dampers in all the supply air collars - RA Grill

10

-

-

... More
Supply & fixing of thermal insulation with min 9 mm thick closed cell anti microbial nitrile rubber with a wrap over the ducting.(Insulation material shall have a density of 60Kg/Cum, Class - O Type) and min 0.7 mm thick Alumiunium cladding over the insulation shall be provided.

50

-

-

... More
Supply & fixing of acoustic insulation with 10 mm thick open cell nitrile rubber and Material with min density of 180 kg/Cum duly fixed inside the ducting having Class O type.

30

-

-

... More
Supply of fresh air filter

1.2

-

-

... More
SITC of 50 mm round duct / Rectangular as required with required support/ required insulation thicknes of min 25 mm nitrile rubber / connecting to each units etc as required

25

-

-

... More
SITC of 75 mm round duct / Rectangular as required with required support/ required insulation thicknes of min 25 mm nitrile rubber / connecting to each units etc as required

50

-

-

... More
SITC of 100 mm round duct / Rectangular as required with required support/ required insulation thicknes of min 25 mm nitrile rubber / connecting to each units etc as required

30

-

-

... More
Exhaust Air Fan with min static of 10 mm or to suit actual site condition including necessary louvers / cowls shall be provided to avoid rain water entry (250 cfm) - Staff Outdoor Unit Room 1

1

-

-

... More
Exhaust Air Fan with min static of 10 mm or to suit actual site condition including necessary louvers / cowls shall be provided to avoid rain water entry (250 cfm) - Staff Out door unit Room 2

1

-

-

... More
Exhaust Air Fan with min static of 10 mm or to suit actual site condition including necessary louvers / cowls shall be provided to avoid rain water entry (500 cfm) - Staff Out door unit Room 3

1

-

-

... More
Supply Air Fan with min static of 15 -20 mm or to suit actual site condition including filter and necessary louvers / cowls shall be provided to avoid rain water entry (800 Cfm) - Receiving Area

1

-

-

... More
Exhaust Air Fan with min static of 10 mm or to suit actual site condition including necessary louvers / cowls shall be provided to avoid rain water entry (950 cfm) - Receiving Area

2

-

-

... More
Supply Air Fan with min static of 15 -20 mm or to suit actual site condition including filter and necessary louvers / cowls shall be provided to avoid rain water entry (300 Cfm) - VRF IDU Fresh Air Supply (Documentation Area)

1

-

-

... More
SITC , Unloading, leading, positioning of 4.0 TR Four way casette type Unit or to Suit for (Projection Room) Unit shall be supplied along with remote control. (Inverter type units Preferred) having an out door unit with suitable condenser fan as per OEM recommendation along with min 3 meters length of soft copper pipe which normally comes along with the machine . Cassette Type / High wall split unit shall also have a drain pump fitted to it as required. Copper pipe insulation shall also be covered in the cost of the units. Support required for IDU and ODU including Stabilizer (Minimum Double Booster) shall be considered. Communication cable between IDU to ODU shall be considered by the bidder and the cost shall be included in this price quoted

1

-

-

... More
Supply of Copper pipe (Both Suction and Liquid line to be considered for costing) for the units along with insulation as per piping specs - Unit 1

25

-

-

... More
SITC , Unloading, leading, positioning 1.5 TR Hi wall Mount type IDU for (Edit Room)

1

-

-

... More
SITC , Unloading, leading, positioning 2.0 TR Hi wall Mount for (Server Room)

1

-

-

... More
SITC , Unloading, leading, positioning 3 TR Four way casette type IDU for (VFX Room)

2

-

-

... More
SITC , Unloading, leading, positioning 4 TR Four way casette type IDU for (View Hall)

2

-

-

... More
SITC , Unloading, leading, positioning 2 TR Four way casette type IDU for (Edit Suite 1)

2

-

-

... More
SITC , Unloading, leading, positioning 2 TR Four way casette type IDU for (Edit Suite 2)

2

-

-

... More
SITC , Unloading, leading, positioning 2 TR Four way casette type IDU for (Edit Room)

1

-

-

... More
SITC , Unloading, leading, positioning 2 TR Four way casette type IDU for (HOD Room)

1

-

-

... More
SITC,Unloading, leading, positioning 16 HP Min Capacity Variable Refrigerant Flow Outdoor unit (Combined Circuit total of 32 HP) with compressor (Variable speed, Scroll), Air cooled condenser, fan motor, vibration isolation pads etc to be considered. (Basement). Unit with lower power consumption at full load / Part load will be prefferred. All compressors shall be of full inverter type

2

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish. The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between outdoor unit & indoor units - Pipe Line Size - 5/8"

60

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish. The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between outdoor unit & indoor units - Pipe Line Size - 3/8"

70

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish. The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between outdoor unit & indoor units - Pipe Line Size - 1/2"

40

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish. The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between outdoor unit & indoor units - Pipe Line Size - 1/4"

12

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish. The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between outdoor unit & indoor units - Pipe Line Size - 3/4"

22

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish. The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between outdoor unit & indoor units - Pipe Line Size - 1 1/8"

30

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish. The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between outdoor unit & indoor units - Pipe Line Size - 1 3/8"

14

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish. The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between outdoor unit & indoor units - Pipe Line Size - 7/8"

6

-

-

... More
SITC of Refrigerant Gas .

40

-

-

... More
SITC of condensate drain piping out of UPVC pipe with necessary insulation, fittings, U trap as required of size from the indoor unit up to the nearest drain point (Overall Measurement is indicated) Drain pipes carrying Condensate water shall be insulated with min 6mm thick elastomeric Nitrile rubber. For proper drainage of condensate and to avoid any fouling smell, U trap shall be provided in drain piping wherever required.

120

-

-

... More
Supply of Remote control for each units

12

-

-

... More
Supply of Refnet Joints

12

-

-

... More
Supply of Interconnecting cable (Power & Control) from Outdoor to Indoor as required by the OEM

140

-

-

... More
Supply of Drain Pump for Hi wall Mount VRF / and for independent Split Unit as required

3

-

-

... More
SITC , Unloading, leading, positioning of 2.0 TR High Wall type Unit (SERVER ROOM). Unit shall be supplied along with remote control Split Air Conditioner with rotary compressor. (Inverter type units Preferred) having an out door unit with suitable condenser fan as per OEM recommendation along with min 3 meters length of soft copper pipe which normally comes along with the machine . Unit shall be supplied along with remote control.Cassette Type / High wall split unit shall also have a drain pump fitted to it as required. Copper pipe insulation shall also be covered in the cost of the units. Support required for IDU and ODU including Stabilizer (Minimum Double Booster) shall be considered in the unit price. Communication cable between IDU to ODU shall be inclusive of this cost.

1

-

-

... More
Supply of Copper Pipe (Cost inclusive of Both Suction and Liquid line ) for the units along with insulation as per piping specs. - Unit 1

15

-

-

... More
Supply of Fresh Air Filter

1

-

-

... More
SITC of 50 mm round duct / Rectangular as required with required support/ required insulation thicknes of min 25 mm nitrile rubber / connecting to each units etc as required

30

-

-

... More
SITC of 100 mm round duct / Rectangular as required with required support/ required insulation thicknes of min 25 mm nitrile rubber / connecting to each units etc as required

40

-

-

... More
SITC Exhaust Air Fan with min static of 10 mm or to suit actual site condition including necessary louvers / cowls shall be provided to avoid rain water entry (350 cfm) - Store Room

1

-

-

... More
Supply Air Fan with min static of 15 -20 mm or to suit actual site condition including filter and necessary louvers / cowls shall be provided to avoid rain water entry (300 Cfm) - View Hall / Edit Suite Cassette Unit FA Supply

2

-

-

... More
Supply of Rubber pads for out door units

1

-

-

... More
Supplying, Fabriccaion of MS Structural support / Channels for IDU s / ODU S to suit including one coat of primer and two coats of enamel / rust proof /epoxy paint. The out door and indoor units should be mounted to have a easy reach for which if reqd hand rails / ladders etc to be provided (For Basement / G floor and First Floor)

2500

-

-

... More
Any Other Miscellenous Charges required for the completion of HVAC works.

1

-

-

... More
Supply, Installation, Leading, Positioning, Testing and commissioning of 44 TR Capacity (To Suit) of 17600CFM, 55 mm static pressure, Floor mounted Double Skin, (48 - 50mm thick PUF panels, density of 40kg/cum, with min 0.6-mm thick inner & 0.8-mm outer skin) air-handling units, with Thermal break profile, Pre-filter section with Pre-filters (90% down to 10 micron) with highest Efficiency along filter frame. The Ahu shall be with preferably 6 row DX Cooling coil section to suit the ODU Selected along with the AHU for Thiruvanthpuram climate. The AHU shall have a drain pan with min 1.2-mm thick Stainless steel (SS 304) material. Pan should be Insulated with min 9-mm thick Nitrile rubber at the bottom. Copper tubes selected shall be of preferably 0.5mm thick and min of 12 Fins Per inch shall be maintained. The contracctor should consider suitable expansion Valve, Filter Drier (AHU KIT if any) so that the AHU is coupled with the selected ODU. Ahu shall also have a DIDW fan blower with fan motor of minimum IE 3 Motor (IE 2 can be provided only if IE 3 is not available for that capacity), fan with drive coupling to suit, along with necessary mounting frame, Vibration isolators, 2 MM GI base frame, Aluminium structural frame work, Fire retardant flexible connection, Marine light, Access door and Access door limit switch, View port for fan section, accessories and as per technical specifications. Coils shall be sized to meet conditions provided in AHU specifications. The Coil face velocity shall not exceed 2.5 M/s. The quoted price shall include the cost of supply, installation, testing and commissioning of air handling unit wall mountable electrical starter panel , main circuit breaker, LCD screen with temperature indicator. Panel shall be preferably wall mounted type, powder coated type. The electrical panel shall have potential free relay contacts to be interlocked with fire alarm control module & BMS on/off command, trip status.

2

-

-

... More
SITC of 11 TR / 12 TR Condensing unit comprising ODU with Scroll compressor and condenser fan unit to suit the above indicated AHU. The conractor shall consider all the interconnecting circuit components required for connecting the AHU including safety & communication between the AHU & ODU.

8

-

-

... More
Supply of Communication & Power Cable between AHU and Outdoor unit to suit

40

-

-

... More
Supply of Panel for AHU (Each Panel to have a switch on / off control of 44 TR Capacity ie 11 X 4 Units)

2

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk or to suit as per OEM Standards, EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm / 13mm thick elastomeric nitrile rubber respectively. Drain pipes carrying Condensate water shall be insulated with min 6mm thick elastomeric Nitrile rubber. For proper drainage of condensate and to avoid any fouling smell, U trap shall be provided in drain piping wherever required. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound and coated with painted 2 coats of resin and hardener to give smooth and paint finish. The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between condensing unit & indoor units - Suction Line - 7/8"

40

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk or to suit as per OEM Standards, EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm / 13mm thick elastomeric nitrile rubber respectively. Drain pipes carrying Condensate water shall be insulated with min 6mm thick elastomeric Nitrile rubber. For proper drainage of condensate and to avoid any fouling smell, U trap shall be provided in drain piping wherever required. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound and coated with painted 2 coats of resin and hardener to give smooth and paint finish. The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between condensing unit & indoor units - Liquid Line - 1 1/8"

40

-

-

... More
Supply of Refrigerant Gas

120

-

-

... More
SITC of condensate drain piping out of UPVC pipe with necessary insulation, fittings, U trap as required of size from the indoor unit up to the nearest drain point .

30

-

-

... More
SITC of Rectangle duct with necessary supporting arrangements, standards of sizing and supporting arrangements - 24G G.I Sheet

15

-

-

... More
SITC of Rectangle duct with necessary supporting arrangements, standards of sizing and supporting arrangements - 22G G.I Sheet

18

-

-

... More
SITC of Rectangle duct with necessary supporting arrangements, standards of sizing and supporting arrangements - 20G G.I Sheet

10

-

-

... More
SITC of Rectangle duct with necessary supporting arrangements, standards of sizing and supporting arrangements - 18G G.I Sheet

25

-

-

... More
Supply and erection of GI Spiral Ducting with nesscessary fittings, joints, flanges, accessories and supports etc.. (Preferably with a gripple support). Ducting shall be powder coated suitably wrt the room as per client advice and the cost is inclusive of necessary coating. 900 mmDia

90

-

-

... More
Supply and erection of GI Spiral Ducting with nesscessary fittings, joints, flanges, accessories and supports etc.. (Preferably with a gripple support). Ducting shall be powder coated suitably wrt the room as per client advice and the cost is inclusive of necessary coating - 700mm Dia

45

-

-

... More
Supply and erection of GI Spiral Ducting with nesscessary fittings, joints, flanges, accessories and supports etc.. (Preferably with a gripple support). Ducting shall be powder coated suitably wrt the room as per client advice and the cost is inclusive of necessary coating - 450 Dia

30

-

-

... More
Supply of Canvas (Fire retardent) along with Damper for supply air for all the units Size - To suit

2

-

-

... More
Supply of VCD for controlling air flow on Main ducts

3

-

-

... More
Supply of Fresh air damper with pre filter to suit

2

-

-

... More
Supply of Fire Damper with Fusible link to suit the return air

8

-

-

... More
SITC of horizontal continuous grill/diffusers of size - 450 Dia Jet Diffusers (24Nos)

5

-

-

... More
Supply of RA Grill

8

-

-

... More
Thermal Insulation - Supply & fixing of thermal insulation with closed cell anti microbial nitrile rubber for the additional new ducts if any provided for Recording theater along with a wrap over the ducting.(Insulation material shall have a density of 60Kg/Cum, Class - O Type) and min 0.7 mm thick Alumiunium cladding over the insulation shall be provided. The thermal insulation with min 9 mm thick closed cell nitrile rubber with a wrap over the ducting.

300

-

-

... More
Supply & fixing of thermal insulation with min 25 mm thick closed cell nitrile rubber (For Exposed Duct) with a wrap over the ducting.

60

-

-

... More
Supply & fixing of acoustic insulation for the new additional ducts if any provided for the recording Theater with Minimum 10 mm thick or as required open cell nitrile rubber and Material with min density of 180 kg/Cum duly fixed inside the ducting having Class O type.

30

-

-

... More
Supply of Rubber pads for out door units

1

-

-

... More
Supplying , Fabrication of MS Structural support / Channels for IDU s / ODU S to suit including one coat of primer and two coats of enamel / rust proof /epoxy paint. The out door and indoor units should be mounted to have a easy reach for which if reqd hand rails / ladders etc to be provided

750

-

-

... More
Any Other Miscellenous Charges required for the completion of HVAC works.

1

-

-

... More
Shifting, Leading, Positioning, re installing,Testing and commissioning of 17 TR x 2 Nos of existing Packaged Unit along with necessary out door units (8.5 TR X 2 units or as with available combination with client place) and fixing the same near the Medium floor AHU room indicated in the drawing. Vendor shall ensure that unit is properly shifted without any damage and shall ensure that the unit shall work to its rated capacity as it is an un used existing units. Any repair work to ensure the unit working to its fullest capacity will be in vendors scope for which the vendor can inspect the units if required.The quoted price shall include the cost of installation, testing, repairing if any and commissioning of electrical indoor / microprocessor unit starter panel (provided with the unit), and its related main circuit breaker, Display screen with temperature indicator. The electrical / microprocessor panel shall be added with a potential free relay contacts which can be interlocked with fire alarm control module & BMS on/off command, trip status. The price quoted shall be inclusive of indoor / outdoor unit shifting etc and its related work in total including any repair works till proper commissioning and handing over the same to client use.

2

-

-

... More
Supply of Communication & Power Cable between Packaged unit to the Outdoor unit so as to suit

80

-

-

... More
SITC, I.e Supply ,Installing, testing, commissioning including Leading, Positioning, of 8.5 / 8.75 TR or as per nearest available capacity by OEM Ductable type Packaged Unit along with necessary out door units (8.5 TR / 8.75 / or to suit X 1 units as available) and fixing the same near the Medium floor AHU room as indicated in the drawing. Vendor shall ensure that unit is properly supplied, integrated with the 2 nos of 17 TR units in the plenum and shall ensure that the unit shall work to its rated capacity. The quoted price shall include the cost of installation, testing, and commissioning of electrical indoor unit starter panel (provided with the unit), and its related main circuit breaker, Display screen with temperature indicator. The electrical panel / microprocessor panel shall be added with a potential free relay contacts which can be interlocked with fire alarm control module & BMS on/off command, trip status. Unit shall have all requisite micro processor units for controlling the temperature and it shall have an option of switching over the operation of compressor when it is more than one numer of compressor.

1

-

-

... More
Supply of Outdoor unit 8.5 TR to suit the packaged unit supplied

1

-

-

... More
Supply of Communication & Power Cable between Packaged unit to the Outdoor unit so as to suit with requisite supports.

30

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk or to suit as per OEM Standards, EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting for the Packaged units as per the colour approved by client / standards. In case if the piping requires insulation in any area, then the same shall be done for the all the lines as required with fittings, valves, and strainer bodies etc with 19mm / 13mm thick elastomeric nitrile rubber respectively. Drain pipes carrying Condensate water shall be insulated with min 6mm thick elastomeric Nitrile rubber for all the units. For proper drainage of condensate and to avoid any fouling smell, U trap shall be provided in drain piping wherever required. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound and coated with painted 2 coats of resin and hardener to give smooth and paint finish. The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between condenser unit & indoor Packaged units - PACKAGE 17TR (2Units) - Liquid Line - 5/8"

70

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk or to suit as per OEM Standards, EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting for the Packaged units as per the colour approved by client / standards. In case if the piping requires insulation in any area, then the same shall be done for the all the lines as required with fittings, valves, and strainer bodies etc with 19mm / 13mm thick elastomeric nitrile rubber respectively. Drain pipes carrying Condensate water shall be insulated with min 6mm thick elastomeric Nitrile rubber for all the units. For proper drainage of condensate and to avoid any fouling smell, U trap shall be provided in drain piping wherever required. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound and coated with painted 2 coats of resin and hardener to give smooth and paint finish. The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between condenser unit & indoor Packaged units - PACKAGE 17TR (2Units) - Discharge Line - 7/8"

70

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk or to suit as per OEM Standards, EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting for the Packaged units as per the colour approved by client / standards. In case if the piping requires insulation in any area, then the same shall be done for the all the lines as required with fittings, valves, and strainer bodies etc with 19mm / 13mm thick elastomeric nitrile rubber respectively. Drain pipes carrying Condensate water shall be insulated with min 6mm thick elastomeric Nitrile rubber for all the units. For proper drainage of condensate and to avoid any fouling smell, U trap shall be provided in drain piping wherever required. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound and coated with painted 2 coats of resin and hardener to give smooth and paint finish. The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between condenser unit & indoor Packaged units - PACKAGE 8.5TR (1Unit) - Liquid Line - 5/8"

20

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk or to suit as per OEM Standards, EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting for the Packaged units as per the colour approved by client / standards. In case if the piping requires insulation in any area, then the same shall be done for the all the lines as required with fittings, valves, and strainer bodies etc with 19mm / 13mm thick elastomeric nitrile rubber respectively. Drain pipes carrying Condensate water shall be insulated with min 6mm thick elastomeric Nitrile rubber for all the units. For proper drainage of condensate and to avoid any fouling smell, U trap shall be provided in drain piping wherever required. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound and coated with painted 2 coats of resin and hardener to give smooth and paint finish. The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between condenser unit & indoor Packaged units - PACKAGE 8.5TR (1Unit) - Discharge Line - 7/8"

20

-

-

... More
Supply of Refrigerant Gas

50

-

-

... More
SITC of condensate drain piping out of UPVC pipe with necessary insulation, fittings, U trap as required of size from the indoor unit up to the nearest drain point.

30

-

-

... More
SITC of Rectangle duct with necessary supporting arrangements, with standard sizing and supporting arrangements - 24G G.I Sheet

10

-

-

... More
SITC of Rectangle duct with necessary supporting arrangements, with standard sizing and supporting arrangements - 22G G.I Sheet

10

-

-

... More
SITC of Rectangle duct with necessary supporting arrangements, with standard sizing and supporting arrangements - 20G G.I Sheet

15

-

-

... More
SITC of Rectangle duct with necessary supporting arrangements, with standard sizing and supporting arrangements - 18G G.I Sheet

18

-

-

... More
Supply and erection of GI Spiral Ducting with nesscessary fittings, joints, flanges, accessories and supports etc.. (Preferably with a gripple support). Ducting shall be powder coated suitably wrt the room as per client advice on colour and the cost is inclusive of necessary coating - 600mm Dia

70

-

-

... More
Supply and erection of GI Spiral Ducting with nesscessary fittings, joints, flanges, accessories and supports etc.. (Preferably with a gripple support). Ducting shall be powder coated suitably wrt the room as per client advice on colour and the cost is inclusive of necessary coating - 550mm Dia

40

-

-

... More
Supply and erection of GI Spiral Ducting with nesscessary fittings, joints, flanges, accessories and supports etc.. (Preferably with a gripple support). Ducting shall be powder coated suitably wrt the room as per client advice on colour and the cost is inclusive of necessary coating - 350mm Dia

50

-

-

... More
Supply of Canvas (Fire retardent) along with Damper for supply air for all the units Size - To suit

5

-

-

... More
Supply of VCD for controlling air flow on Main ducts

1.5

-

-

... More
Supply of Fresh air damper with pre filter to suit

1

-

-

... More
Supply of Fire Damper with Fusible link to suit the return air

2.5

-

-

... More
SITC of horizontal continuous grill/diffusers of sizes 350mm Dia Jet Diffusers (24Nos)

3.5

-

-

... More
Supply of RA Grill

4

-

-

... More
Thermal Insulation - Supply & fixing of thermal insulation with closed cell anti microbial nitrile rubber .(Insulation material shall have a density of 60Kg/Cum, Class - O Type) Ducting insulation shall be done with in the inside surface of the duct and extrenally powder coating of the duct with requisite color shall be provided for the duct as per client requirement. Thermal insulation with min 9 mm thick closed cell nitrile rubber within ducting.

260

-

-

... More
Supply & fixing of thermal insulation with min 25 mm thick closed cell nitrile rubber (For Exposed Duct) with al.foil finish and a UV wrap over the ducting wherever applicable.

15

-

-

... More
Supply & fixing of acoustic insulation for the ducts provided with Minimum 10 mm thick or as required open cell nitrile rubber and Material with min density of 180 kg/Cum duly fixed inside the ducting having Class O type.

50

-

-

... More
Supply of Rubber pads for out door units

1

-

-

... More
Supplying, Fabrication of MS Structural support / Channels for IDU s / ODU S to suit including one coat of primer and two coats of enamel / rust proof /epoxy paint. The out door and indoor units should be mounted to have a easy reach for which if reqd hand rails / ladders etc to be provided

500

-

-

... More
Miscellenoeous charges like, required civil works etc for completing HVAC (demolishing & finishing the damaged portion)

1

-

-

... More
DI building - SITC , Unloading, leading, positioning 8.5 TR Ductable Split Unit circuit with air cooled outdoor unit SCROLL compressor (Inverter compressor can also be considered based on OEM availability), having suitable condenser fan / or as per OEM recommendation and separate isolators to be provided for each unit towards maintenance purpose . The Unit shall have all interconnecting communication cables so as to have effective communication between IDU & with ODU. The price quoted shall be inclusive of IDU and ODU with necessary supporting arrangements for the units indoor and outdoor as required at site

3

-

-

... More
Supply of Communication Cable between IDU and Outdoor unit to suit

65

-

-

... More
SITC of Rectangle duct with necessary fittings, standards of sizing and supporting arrangements. All ducts used shall be of factory fabricated type only . Any minor connection work at site will have to be carried out with the prior approval of client only. The GI Sheets used shall be of Min 120 GSM of Zinc coating and a necessary test certificate as required shall be submitted to the client approval as and when required by client. Bidder to ensure that the duct is supported with necessary stiffners etc to handle the insulation weight as duct is insulated both acoustically and thermally for full length - 24G G.I Sheet (Upto 750mm)

75

-

-

... More
SITC of Rectangle duct with necessary fittings, standards of sizing and supporting arrangements. All ducts used shall be of factory fabricated type only . Any minor connection work at site will have to be carried out with the prior approval of Client only. The GI Sheets used shall be of Min 120 GSM of Zinc coating and a necessary test certificate as required shall be submitted to the client approval as and when required by client consultant. Bidder to ensure that the duct is supported with necessary stiffners etc to handle the insulation weight as duct is insulated both acoustically and thermally for full length - 22G G.I Sheet (from 751 - 1500 mm)

10

-

-

... More
SITC of Rectangle duct with necessary fittings, standards of sizing and supporting arrangements. All ducts used shall be of factory fabricated type only . Any minor connection work at site will have to be carried out with the prior approval of Client only. The GI Sheets used shall be of Min 120 GSM of Zinc coating and a necessary test certificate as required shall be submitted to the client approval as and when required by client consultant. Bidder to ensure that the duct is supported with necessary stiffners etc to handle the insulation weight as duct is insulated both acoustically and thermally for full length - 20G G.I Sheet (From 1501 - 2250mm)

10

-

-

... More
SITC of Canvas (Fire retardent) along with Damper for supply air for all the units Size - To suit

3

-

-

... More
SITC of VCD (Volume Control Damper)- with Multi Opposed Blade type & frame shall be with Galvanized Iron with min thickness of 18 gauge of frame and min 20 G thick blade shall be used.

3

-

-

... More
SITC of Fresh air damper with pre filter to suit

1.5

-

-

... More
SITC of Fire Damper with Fusible link to suit the return air (Fire dampers shall be with at least 1.5 hours fire rating. Damper blades shall be one piece folded construction manufactured from high strength galvanized steel Opposed blade type. Damper frames shall be of 18 gauge GI and the blades of min 20 gauge GI).

0.75

-

-

... More
The supply and return air grills / diffusers shall be anodized aluminium construction, square or rectangular in type. Supply air grill / diffusers shall be provided with Al Blade material multi Opposed dampers in all the supply air collars. In case of diff size of grills / diffusers used then the same shall be considered in sq mtr value to the nearest thickness / sizes. The colour of the grill shall be decided by client and contractor to ensure that the requisite colour of grill is supplied without any additional cost. (Horizontal Continuous grill of 6 inch height with 15 deg c Delflection or as required at site) - Air Grill with Damper

3

-

-

... More
Supply of RA Grill

5.3

-

-

... More
Supply & fixing of thermal insulation with min 9 mm thick closed cell anti microbial nitrile rubber with a wrap over the ducting.(Insulation material shall have a density of 60Kg/Cum, Class - O Type) and min 0.7 mm thick Alumiunium cladding over the insulation shall be provided. (Cost is inclusive of Duct support for handling insulation units

100

-

-

... More
Supply & fixing of acoustic insulation with 20 mm thick open cell nitrile rubber and Material with min density of 180 kg/Cum duly fixed inside the ducting having Class O type. (Cost is inclusive of Duct support for handling insulation units.)

95

-

-

... More
SITC of 2.0 TR Four way casette type AirConditioner (Confirmation Room 1 & 2)conisiting of total unit including Grills etc along with drain pump etc as required for complete installation including necessary supporting arrangement etc.

2

-

-

... More
SITC of 2.0 TR Four way casette type AirConditioner (Discussion room)conisiting of total unit including Grills etc along with drain pump etc as required for complete installation including necessary supporting arrangement etc.

1

-

-

... More
SITC of 2.0 TR Four way casette type AirConditioner (Reception)conisiting of total unit including Grills etc along with drain pump etc as required for complete installation including necessary supporting arrangement etc.

1

-

-

... More
SITC of 1.5 TR Four way casette type AirConditioner (HOD room)conisiting of total unit including Grills etc along with drain pump etc as required for complete installation including necessary supporting arrangement etc.

1

-

-

... More
SITC,Unloading, leading, positioning 10 HP Min Capacity Variable Refrigerant Flow Outdoor unit with compressor (Variable speed, Scroll), Air cooled condenser, fan motor, vibration isolation pads etc to be considered. Unit with lower power consumption at full load / Part load will be prefferred.

1

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish. Note: The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between outdoor unit & indoor units - DI SUITE (3 Units) DUCTABLE 8.5 TR - Suite - 1 - Suction Line - 1 1/8"

15

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish. Note: The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between outdoor unit & indoor units - DI SUITE (3 Units) DUCTABLE 8.5 TR - Suite - 1 - Liquid Line - 5/8"

15

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish. Note: The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between outdoor unit & indoor units - DI SUITE (3 Units) DUCTABLE 8.5 TR - Suite - 2 - Suction Line - 1 1/8"

25

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish. Note: The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between outdoor unit & indoor units - DI SUITE (3 Units) DUCTABLE 8.5 TR - Suite - 2 - Liquid Line - 5/8"

25

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish. Note: The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between outdoor unit & indoor units - DI SUITE (3 Units) DUCTABLE 8.5 TR - Suite - 3 - Suction Line - 1 1/8"

30

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish. Note: The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between outdoor unit & indoor units - DI SUITE (3 Units) DUCTABLE 8.5 TR - Suite - 3 - Liquid Line - 5/8"

30

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish. Note: The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between outdoor unit & indoor units - DI BUILDING (5 Indoor with One Out Door Unit for VRF Unit) - Piping Size - 5/8"

35

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish. Note: The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between outdoor unit & indoor units - DI BUILDING (5 Indoor with One Out Door Unit for VRF Unit) - Piping Size - 3/8"

60

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish. Note: The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between outdoor unit & indoor units - DI BUILDING (5 Indoor with One Out Door Unit for VRF Unit) - Piping Size - 7/8"

30

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish. Note: The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between outdoor unit & indoor units - DI BUILDING (5 Indoor with One Out Door Unit for VRF Unit) - Piping Size - 1/2"

25

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish. Note: The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between outdoor unit & indoor units - DI BUILDING (5 Indoor with One Out Door Unit for VRF Unit) - Piping Size - 1/4"

20

-

-

... More
SITC of Refrigerant Gas - VRF

12

-

-

... More
SITC of Refrigerant Gas - Ductable Unit

30

-

-

... More
SITC of condensate drain piping out of UPVC pipe with necessary insulation, fittings, U trap as required of size from the indoor unit up to the nearest drain point (Overall Measurement is indicated) Drain pipes carrying Condensate water shall be insulated with min 6mm thick elastomeric Nitrile rubber. For proper drainage of condensate and to avoid any fouling smell, U trap shall be provided in drain piping wherever required. Size of pipe shall be with in 50 mm to 100 mm or as required at site

90

-

-

... More
Supply of Remote control for each units

5

-

-

... More
Supply of Refnet Joints

4

-

-

... More
Interconnecting cable (Power & Control) from Outdoor to Indoor as required by the OEM for VRF

90

-

-

... More
SITC , Unloading, leading, positioning of 3 TR Four Way Cassette Type Units along with Remote Control for Projection room (Working Unit) Split Air Conditioner with rotary compressor. (Inverter type units Preferred) having an out door unit with suitable condenser fan as per OEM recommendation along with min 3 meters length of soft copper pipe which normally comes along with the machine . High wall split unit shall also have a drain pump fitted to it as required. Copper pipe insulation shall also be covered in the cost of the units. Cos is inclusive of Supports for IDU and ODU including Stabilizer (Minimum Double Booster) and Communication cable between IDU to ODU.

1

-

-

... More
SITC , Unloading, leading, positioning of 2 TR High Wall Mount Unit along with Remote Control for Projection room (Standby Unit) Split Air Conditioner with rotary compressor. (Inverter type units Preferred) having an out door unit with suitable condenser fan as per OEM recommendation along with min 3 meters length of soft copper pipe which normally comes along with the machine . High wall split unit shall also have a drain pump fitted to it as required. Copper pipe insulation shall also be covered in the cost of the units. Cos is inclusive of Supports for IDU and ODU including Stabilizer (Minimum Double Booster) and Communication cable between IDU to ODU.

1

-

-

... More
Supply of copper pipes both suction and Liquid line - Unit 1 (Cassette Type)

24

-

-

... More
Supply of copper pipes both suction and Liquid line - Unit 2 (Hi wall Type Stand By)

18

-

-

... More
2 TR High Wall Mount Units along with Remote Control for SERVER ROOM - (1 Working and 1 Standby Unit)

2

-

-

... More
Supply of copper pipes both suction and Liquid line - Unit 1 (Hi wall Type Working)

18

-

-

... More
Supply of copper pipes both suction and Liquid line - Unit 2 (Hi wall Type Stand By)

14

-

-

... More
3 TR Four Way Cassette Type Units along with Remote Control for Projection room (Working Unit) for DI 3

1

-

-

... More
2 TR High Wall Mount Units along with Remote Control for Projection room (Standby Unit) for DI 3

1

-

-

... More
Supply of copper pipes both suction and Liquid line - Unit 1 (Cassette Type)

24

-

-

... More
Supply of copper pipes both suction and Liquid line - Unit 2 (Hi wall Type Stand By)

18

-

-

... More
Supply of Drain Pump for Hi wall Mount VRF / Split AC Unit as required. (For Cassette Unit inbuilt drain pump is considered)

4

-

-

... More
Supply of Rubber pads for out door units

1

-

-

... More
Supply, Fabricaion of MS Structural support / Channels for IDU s / ODU S to suit including one coat of primer and two coats of enamel / rust proof /epoxy paint. The out door and indoor units should be mounted to have a easy reach for which if reqd hand rails / ladders etc to be provided

550

-

-

... More
Supply of Fresh Air Filter

1

-

-

... More
SITC of 75 mm round duct / Rectangular as required with required support/ required insulation thicknes of min 25 mm nitrile rubber / connecting to each units etc as required for VRF IDU FA / Individual Cassette AC Connection

50

-

-

... More
Supply Air Fan with min static of 15-20 mm or to suit actual site condition including filter and necessary louvers / cowls shall be provided to avoid rain water entry (300 cfm) Battery Room

1

-

-

... More
Supply of Exhaust Air Fan with min static of 10 mm or to suit actual site condition including necessary louvers / cowls shall be provided to avoid rain water entry (350 cfm) - Battery Room

1

-

-

... More
Supply of Exhaust Air Fan with min static of 10 mm or to suit actual site condition including necessary louvers / cowls shall be provided to avoid rain water entry (350 cfm) - Stores

1

-

-

... More
Supply Air Fan with min static of 15 -20 mm or to suit actual site condition including filter and necessary louvers / cowls shall be provided to avoid rain water entry (250 cfm) DI Suite room 3

1

-

-

... More
Miscellenoeous charges like, required civil works etc for completing HVAC (demolishing & finishing the damaged portion)

1

-

-

... More
OFFICE BUILDING - SITC of 2.0 TR Four way Cassette Type IDU / Hi wall Mount Unit ( Chairman room). Unit shall be considered with Grills, and with drain pump etc as required for complete installation including necessary supporting arrangement etc.

1

-

-

... More
OFFICE BUILDING - SITC of 1.5 TR Four way Cassette Type IDU / Hi wall Mount Unit (M.D room). Unit shall be considered with Grills, and with drain pump etc as required for complete installation including necessary supporting arrangement etc.

1

-

-

... More
OFFICE BUILDING - SITC of 3.0 TR Four way Cassette Type IDU / Hi wall Mount Unit (Board room). Unit shall be considered with Grills, and with drain pump etc as required for complete installation including necessary supporting arrangement etc.

2

-

-

... More
OFFICE BUILDING - SITC of 1.5 TR Four way Cassette Type IDU / Hi wall Mount Unit (Studio manager room). Unit shall be considered with Grills, and with drain pump etc as required for complete installation including necessary supporting arrangement etc.

1

-

-

... More
OFFICE BUILDING - SITC of 2.0 TR Four way Cassette Type IDU / Hi wall Mount Unit (PRO). Unit shall be considered with Grills, and with drain pump etc as required for complete installation including necessary supporting arrangement etc.

1

-

-

... More
OFFICE BUILDING - SITC of 3.0 TR Four way Cassette Type IDU / Hi wall Mount Unit (Recepion & Waiting Longue). Unit shall be considered with Grills, and with drain pump etc as required for complete installation including necessary supporting arrangement etc.

1

-

-

... More
OFFICE BUILDING - SITC of 1.5 TR Four way Cassette Type IDU / Hi wall Mount Unit (Huddle room - 1). Unit shall be considered with Grills, and with drain pump etc as required for complete installation including necessary supporting arrangement etc.

1

-

-

... More
OFFICE BUILDING - SITC of 1.5 TR Four way Cassette Type IDU / Hi wall Mount Unit (Huddle room - 2). Unit shall be considered with Grills, and with drain pump etc as required for complete installation including necessary supporting arrangement etc.

1

-

-

... More
OFFICE BUILDING - SITC of 2.0 TR Four way Cassette Type IDU / Hi wall Mount Unit (Office room). Unit shall be considered with Grills, and with drain pump etc as required for complete installation including necessary supporting arrangement etc.

1

-

-

... More
SITC,Unloading, leading, positioning 24 HP Min Capacity Variable Refrigerant Flow Outdoor unit (Combined Circuit) with compressor (Variable speed, Scroll), Air cooled condenser, fan motor, vibration isolation pads etc to be considered. (Basement). Unit with lower power consumption at full load / Part load will be prefferred. All compressors shall be of full inverter type.

1

-

-

... More
Supply of Interconnecting cable (Power & Control) from Outdoor to Indoor as required by the OEM for VRF

100

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish. The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between outdoor unit & indoor units - Pipe Line Size - 5/8"

45

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish. The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between outdoor unit & indoor units - Pipe Line Size - 3/8"

50

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish. The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between outdoor unit & indoor units - Pipe Line Size - 1/2"

26

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish. The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between outdoor unit & indoor units - Pipe Line Size - 1/4"

24

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish. The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between outdoor unit & indoor units - Pipe Line Size - 3/4"

15

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish. The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between outdoor unit & indoor units - Pipe Line Size - 1 1/8"

12

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish. The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between outdoor unit & indoor units - Pipe Line Size - 1 3/8"

15

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish. The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between outdoor unit & indoor units - Pipe Line Size - 7/8"

6

-

-

... More
SITC , Unloading, leading, positioning of 2.0 TR HI Wall Mount Unit - Split Air Conditioner with rotary compressor) or to Suit for (Chairman Room) Unit shall be supplied along with remote control . (Inverter type units Preferred) having an out door unit with suitable condenser fan as per OEM recommendation along with min 3 meters length of soft copper pipe which normally comes along with the machine . Cassette Type / High wall split unit shall also have a drain pump fitted to it as required. Copper pipe insulation shall also be covered in the cost of the units. The cost is inclusive of Supports required for IDU and ODU including Stabilizer and Communication cable between IDU to ODU.

1

-

-

... More
SITC , Unloading, leading, positioning of 1.5 TR HI Wall Mount Unit - Split Air Conditioner with rotary compressor) or to Suit for (Chairman Room) Unit shall be supplied along with remote control . (Inverter type units Preferred) having an out door unit with suitable condenser fan as per OEM recommendation along with min 3 meters length of soft copper pipe which normally comes along with the machine . Cassette Type / High wall split unit shall also have a drain pump fitted to it as required. Copper pipe insulation shall also be covered in the cost of the units. The cost is inclusive of Supports required for IDU and ODU including Stabilizer and Communication cable between IDU to ODU.

1

-

-

... More
Supply of Copper Pipe for both Suction and Liquid line along with insulation as per piping specs - 2 TR Chair Man Room Unit (Piping)

20

-

-

... More
Supply of Copper Pipe for both Suction and Liquid line along with insulation as per piping specs - 1.5 TR MD Room Unit (Piping)

25

-

-

... More
Supply of Fresh Air Filter

0.5

-

-

... More
SITC of 50 mm round duct / Rectangular as required with required support/ required insulation thicknes of min 25 mm nitrile rubber / connecting to each units etc as required

50

-

-

... More
SITC of 75 mm round duct / Rectangular as required with required support/ required insulation thicknes of min 25 mm nitrile rubber / connecting to each units etc as required

20

-

-

... More
SITC of 100 mm round duct / Rectangular as required with required support/ required insulation thicknes of min 25 mm nitrile rubber / connecting to each units etc as required

15

-

-

... More
Supply Air Fan with min static of 15 -20 mm or to suit actual site condition including filter and necessary louvers / cowls shall be provided to avoid rain water entry (400 Cfm) - To VRF Units (Inline high static Low Noice Fan)

1

-

-

... More
Supply Air Fan with min static of 15 -20 mm or to suit actual site condition including filter and necessary louvers / cowls shall be provided to avoid rain water entry (300 Cfm) - To VRF Units (Inline high static Low Noice Fan)

1

-

-

... More
Supply of Exhaust Air Fan with min static of 10 mm or to suit actual site condition including necessary louvers / cowls shall be provided to avoid rain water entry (350 cfm) - Store room

1

-

-

... More
SITC of 2.0 TR Four way Cassette Type IDU / Hi wall Mount Unit , inclusive of Grills, and with drain pump etc complete installation including necessary supporting arrangement etc.( VIP waiting area)

1

-

-

... More
SITC , Unloading, leading, positioning 5.5 / 6 (AS PER OEM AVAILABILITY) TR Ductable with Remote control (Corded Remote Preferably or as per client requirement) for (Dubbing) including all necessary kits for interconnecting with VRF. Unit shall also be supplied along with drain pump as required

1

-

-

... More
SITC , Unloading, leading, positioning 2.0 TR Ductable with Remote control (Corded Remote Preferably or as per client requirement) for (Console) including all necessary kits for interconnecting with VRF. Unit shall also be supplied along with drain pump as required

1

-

-

... More
SITC , Unloading, leading, positioning 2.0 TR Ductable with Remote control (Corded Remote Preferably or as per client requirement) for (Console) including all necessary kits for interconnecting with VRF. Unit shall also be supplied along with drain pump as required

1

-

-

... More
SITC of 3.0 TR Four way Cassette Type IDU / Hi wall Mount Unit , inclusive of Grills, and with drain pump etc complete installation including necessary supporting arrangement etc.(Store room)

1

-

-

... More
SITC of 3.0 TR Four way Cassette Type IDU / Hi wall Mount Unit , inclusive of Grills, and with drain pump etc complete installation including necessary supporting arrangement etc.(Reception and waiting longue)

1

-

-

... More
SITC , Unloading, leading, positioning 3.0 TR Ductable with Remote control (Corded Remote Preferably or as per client requirement) for (Folley Studio) including all necessary kits for interconnecting with VRF. Unit shall also be supplied along with drain pump as required

1

-

-

... More
SITC,Unloading, leading, positioning 24 HP Min Capacity Variable Refrigerant Flow Outdoor unit (Combined Circuit) with compressor (Variable speed, Scroll), Air cooled condenser, fan motor, vibration isolation pads etc to be considered. (Basement). Unit with lower power consumption at full load / Part load will be prefferred. All compressors shall be of full inverter type.

1

-

-

... More
Supply of Interconnecting cable (Power & Control) from Outdoor to Indoor as required by the OEM for VRF

100

-

-

... More
OFFICE BUILDING - SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish. The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between outdoor unit & indoor units - Pipe Line Size - 5/8"

47

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish. The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between outdoor unit & indoor units - Pipe Line Size - 3/8"

52

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish. The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between outdoor unit & indoor units - Pipe Line Size - 1/2"

22

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish. The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between outdoor unit & indoor units - Pipe Line Size - 1/4"

15

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish. The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between outdoor unit & indoor units - Pipe Line Size - 3/4"

20

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish. The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between outdoor unit & indoor units - Pipe Line Size - 1 1/8"

12

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish. The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between outdoor unit & indoor units - Pipe Line Size - 1 3/8"

14

-

-

... More
SITC of Inter connected copper refrigerant piping with necessary supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The pipings shall be coated with minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line along with all fittings, valves, and strainer bodies etc with 19mm for VRF Units/ 13mm for Ductable & Condensing units thick elastomeric nitrile rubber respectively. All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc.To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation. Fiber glass tape shall be helically wound to give smooth and paint finish. The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports, as required with all fittings between outdoor unit & indoor units - Pipe Line Size - 7/8"

6

-

-

... More
SITC of Rectangle duct with necessary fittings, following SMACNA standards of sizing and supporting arrangements. All ducts used shall be of factory fabricated type only . Any minor connection work at site will have to be carried out with the prior approval of consultant / Client only. The GI Sheets used shall be of Min 120 GSM of Zinc coating and a necessary test certificate as required shall be submitted to the client approval as and when required by client . All ductings shall be suitably supported with necessary stiffners provided on the ducts so as to reduce vibrations and to handle the insulation weight since complete ducts will be both thermally and acoustically insulated - 24G G.I Sheet (Upto 750mm)

52

-

-

... More
SITC of Rectangle duct with necessary fittings, following SMACNA standards of sizing and supporting arrangements. All ducts used shall be of factory fabricated type only . Any minor connection work at site will have to be carried out with the prior approval of consultant / Client only. The GI Sheets used shall be of Min 120 GSM of Zinc coating and a necessary test certificate as required shall be submitted to the client approval as and when required by client . All ductings shall be suitably supported with necessary stiffners provided on the ducts so as to reduce vibrations and to handle the insulation weight since complete ducts will be both thermally and acoustically insulated - 20G G.I Sheet (From 1501 - 2250mm)

2

-

-

... More
SITC of Canvas (Fire retardent) for supply air for all the units Size - To suit

4

-

-

... More
SITC of VCD (Volume Control Damper)- with Multi Opposed Blade type & frame shall be with Galvanized Iron with min thickness of 18 gauge of frame and min 20 G thick blade shall be used.

3

-

-

... More
SITC of Fresh air damper with pre filter to suit

2

-

-

... More
SITC of Fire Damper with Fusible link to suit the return air (Fire dampers shall be with at least 1.5 hours fire rating. Damper blades shall be one piece folded construction manufactured from high strength galvanized steel Opposed blade type. Damper frames shall be of 18 gauge GI and the blades of min 20 gauge GI).

0.5

-

-

... More
supply and fixing of Air Diffuser / Grill with Damper, it shall be anodized aluminium construction, square or rectangular in type. Supply air grill / diffusers shall be provided with Al Blade material multi Opposed dampers in all the supply air collars. The grills / diffusers selected shall have a low NC of around 25. In case of diff size of grills / diffusers used then the same shall be considered in sq mtr value to the nearest thickness / sizes. Diffuser colour shall be decided by client and contractor has to ensure that the requisite colour of grill is supplied without any additional cost / i.e inclusive of cost of spray painting / coating.

2.5

-

-

... More
supply and fixing of Diffuser / RA Grill, it shall be anodized aluminium construction, square or rectangular in type. Supply air grill / diffusers shall be provided with Al Blade material multi Opposed dampers in all the supply air collars. The grills / diffusers selected shall have a low NC of around 25. In case of diff size of grills / diffusers used then the same shall be considered in sq mtr value to the nearest thickness / sizes. Diffuser colour shall be decided by client and contractor has to ensure that the requisite colour of grill is supplied without any additional cost / i.e inclusive of cost of spray painting / coating.

7

-

-

... More
Supply & fixing of thermal insulation with min 25 mm thick (for Exposed area) closed cell anti microbial nitrile rubber with a wrap over the ducting.(Insulation material shall have a density of 60Kg/Cum, Class - O Type) and min 0.7 mm thick Alumiunium cladding over the insulation shall be provided.

12

-

-

... More
Supply & fixing of thermal insulation with min 9 mm thick (for Non Exposed / Air conditioned area) closed cell anti microbial nitrile rubber with a wrap over the ducting.(Insulation material shall have a density of 60Kg/Cum, Class - O Type) and min 0.7 mm thick Alumiunium cladding over the insulation shall be provided.

45

-

-

... More
Supply & fixing of thermal insulation with min 50 mm thick Thermocol with wire mesh wrapped and cement plastering done for the supply air / Return air ducting exposed to Atmosphere

0.5

-

-

... More
Supply & fixing of acoustic insulation Minimum 20 mm thick or as required open cell nitrile rubber and Material with min density of 180 kg/Cum duly fixed inside the ducting having Class O type. (Complete Duct for Dubbing, Console room - 2 nos and Foley studio shall be acoustically insulated)

54

-

-

... More
Supply of Fresh Air Filter

0.5

-

-

... More
SITC of 50 mm round duct / Rectangular as required with required support/ required insulation thicknes of min 25 mm nitrile rubber / connecting to each units etc as required

40

-

-

... More
SITC of Refrigerant Gas - VRF

30

-

-

... More
SITC of condensate drain piping out of UPVC pipe with necessary insulation, fittings, U trap as required of size from the indoor unit up to the nearest drain point (Overall Measurement is indicated) Drain pipes carrying Condensate water shall be insulated with min 6mm thick elastomeric Nitrile rubber or as required to avoid sweating. For proper drainage of condensate and to avoid any fouling smell, U trap shall be provided in drain piping wherever required. Size of pipe shall be with in 50 mm to 100 mm or as required at site (Both Left & Right WIng)

160

-

-

... More
Supply of Remote control for each units (Both Left and Right wing)

15

-

-

... More
Supply of Refnet Joints (Both Left and Right wing)

15

-

-

... More
Supply of Drain Pump for Hi wall Mount VRF / and for independent Split Unit as required for MD and Chair Man Room Stand By Units

2

-

-

... More
Supply of Rubber pads for out door units

1

-

-

... More
Supply, Fabriation of MS Structural support / Channels for IDU s / ODU S to suit including one coat of primer and two coats of enamel / rust proof /epoxy paint. The out door and indoor units should be mounted to have a easy reach for which if reqd hand rails / ladders etc to be provided

600

-

-

... More
Miscellenoeous charges like, required civil works etc for completing HVAC (demolishing & finishing the damaged portion)

1

-

-

... More
Part 6.Internal Electrical , Fire alarm & Elevator works

-

-

-

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.

1477

-

-

... More
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.

20

-

-

... More
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.

7400

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2x1.5 sq.mm + 1x1.5 sq.mm earth wire

9499

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

6438

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 4 X 6 sq. mm + 2 X 6 sq. mm earth wire

1465

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 4 X 10 sq. mm + 2 X 6 sq. mm earth wire

1830

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 4 X 16 sq. mm + 2 X 6 sq. mm earth wire

380

-

-

... More
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair

5135

-

-

... More
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.

1800

-

-

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm

11525

-

-

... More
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. 100 mm X 100 mm X 60 mm deep

298

-

-

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet

304

-

-

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Telephone socket outlet

159

-

-

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. TV antenna socket outlet

50

-

-

... More
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

217

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).

366

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.

175

-

-

... More
Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required 1 run of Cable

4575

-

-

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator 8 way, Double door

1

-

-

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator 12 way, Double door

27

-

-

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole

1220

-

-

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole

28

-

-

... More
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps

2

-

-

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole

90

-

-

... More
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps

27

-

-

... More
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps

35

-

-

... More
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 amps

1

-

-

... More
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps

25

-

-

... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residualcurrent circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps

28

-

-

... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residualcurrent circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps

37

-

-

... More
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

173

-

-

... More
Supplying and fixing 30 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 amps "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

15

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 300 mm width X 50 mm depth X 1.6 mm thickness

110

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 450 mm width X 62.5 mm depth X 2.0 mm thickness

110

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 600 mm width X 62.5 mm depth X 2.0 mm thickness

90

-

-

... More
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required

63

-

-

... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

48

-

-

... More
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)

1455

-

-

... More
Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.

920

-

-

... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

770

-

-

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.

900

-

-

... More
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube,having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.

81

-

-

... More
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)

2520

-

-

... More
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)

850

-

-

... More
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.

73

-

-

... More
Laying copper/ G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.

20

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ x 35 Sq.mm. AYFY, XLPE, Al, UG cable

44

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 x 16 Sq.mm. AYFY, XLPE, Al, UG cable

50

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 x 25 Sq.mm. AYFY, XLPE, Al, UG cable

52

-

-

... More
Supplying, testing and commissioning of Passive Infrared (PIR) technology based occupancy sensor with day light dimming (lighting level shall be regulated as per availability of natural day light in an area along with occupancy detection .) having high preformance, regulating programmable type, suitable for connected load upto 10 Amp, for mounting height up to 2.8 mtr and for 5 m diameter coverage area along with necessary fixing arrangements i/c programming at site etc. complete as required.

36

-

-

... More
Supplying, installation, testing and commissioning of Microwave technology based occupancy sensor having high preformance, non regulating programmable type, suitable for connected load upto 10 Amp, for mounting height up to 2.6 mtr and for 5m x 20 m coverage area along with necessary fixing arrangements i/c programming at site etc. complete as required.

33

-

-

... More
Supply and wiring points according to IS 732-1989 through the existing conduit with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (Group B/ RoHS compliant modular accessories). Call bell point with 6 A bell push at one end and 6 A, 3 plate ceiling rose at other end - Medium point

16

-

-

... More
Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required. 1200mm sweep -5star rated ceiling fan complete with 300mm down rod , canopies, shackeles and blades and resistance type regulator working on 230V/240V single phase A/C

44

-

-

... More
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 4 way (8+12) - three phase double cover (IP 42/43)

21

-

-

... More
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 8 way (8+24) - three phase double cover (IP 42/43

30

-

-

... More
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 8 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)

11

-

-

... More
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil). 3 core 10 sq mm

150

-

-

... More
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil). 3½C x 35 Sq.mm. AYFY, XLPE, Al, UG cable

540

-

-

... More
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil). 4C x 16 Sq.mm. AYFY, XLPE, Al, UG cable

580

-

-

... More
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil). 4C x 25 Sq.mm. AYFY, XLPE, Al, UG cable

300

-

-

... More
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 3½C x 35 Sq.mm. AYFY, XLPE, Al, UG cable

860

-

-

... More
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 4C x 16 Sq.mm. AYFY, XLPE, Al, UG cable

810

-

-

... More
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 4C x 25 Sq.mm. AYFY, XLPE, Al, UG cable

650

-

-

... More
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 3742019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.

139

-

-

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Data socket outlet

149

-

-

... More
Supply, erection, testing and commissioning of 18 W LED down lighter fitting with cool day light made out of CRCA powder coated body, aluminium reflectors, poly methyl meth acrylate (PMMA) diffuser, glare free light, suitable for recessed / surface mounting including electronic drivers, day light colour LED lamps, inter connecting wiring including accessories all inclusive.

381

-

-

... More
Supply, erection, testing and commissioning of 24 W LED down lighter fitting with cool day light, made out of CRCA powder coated body, aluminium reflectors, poly methyl meth acrylate (PMMA) diffuser, glare free light, suitable for recessed / surface mounting including electronic drivers, day light colour LED lamps, inter connecting wiring including accessories all inclusive.

107

-

-

... More
Supply, erection, testing and commissioning of 36 W LED down lighter fitting with cool day light, made out of CRCA powder coated body, aluminium reflectors, poly methyl meth acrylate (PMMA) diffuser, glare free light, suitable for recessed / surface mounting including electronic drivers, day light colour LED lamps, inter connecting wiring including accessories all inclusive.

522

-

-

... More
Supply, erection, testing and commissioning of 18 W LED down lighter fittingmade out of CRCA powder coated body, aluminium reflectors, poly methyl meth acrylate (PMMA) diffuser, glare free light, suitable for recessed / surface mounting including Sealed maintenance free rechargable batteries with a battery autonomy of 30 minutes, inbuilt battery charger, fuse, test switch, electronic drivers, day light colour LED inter connecting wiring etc., including accessories all inclusive.

66

-

-

... More
Supply, erection, testing and commissioning of 24 W LED down lighter fitting with cool day light, made out of CRCA powder coated body, aluminium reflectors, poly methyl meth acrylate (PMMA) diffuser, glare free light, suitable for recessed / surface mounting including Sealed maintenance free rechargable batteries with a battery autonomy of 30 minutes, inbuilt battery charger, fuse, test switch, electronic drivers, day light colour LED inter connecting wiring etc., including accessories all inclusive.

24

-

-

... More
Supply, erection, testing and commissioning of 36 W LED down lighter fitting with with self contained battery with a battery autonomy of 30 minutes with cool day light, made out of CRCA powder coated body, aluminium reflectors, poly methyl meth acrylate (PMMA) diffuser, glare free light, suitable for recessed / surface mounting including Sealed maintenance free rechargable batteries with a battery autonomy of 30 minutes, inbuilt battery charger, fuse, test switch, electronic drivers, day light colour LED inter connecting wiring etc., including accessories all inclusive.

113

-

-

... More
Supply, erection, testing and commissioning of 10 W LED bulk head fitting with cool day light suitable for surface mounting, made out of CRCA powder coated body, aluminium reflectors, poly methyl meth acrylate (PMMA) diffuser, Suitable for fitting including electronic drivers, day light colour LED lamps, inter connecting wiring including accessories all inclusive.

52

-

-

... More
Supply, erection, testing and commissioning of 150 W LED flood light fitting with cool day light suitable for surface / recessed mounting, made out of CRCA powder coated body, aluminium reflectors, poly methyl meth acrylate (PMMA) diffuser, glare free light, including electronic drivers, day light colour LED lamps, inter connecting wiring including accessories all inclusive.

42

-

-

... More
Supply, erection, testing and commissioning of 250 W LED Flood light fitting with cool day light suitable for surface / recessed mounting, made out CRCA powder coated body, aluminium reflectors, poly methyl meth acrylate (PMMA) diffuser, glare free light, including electronic drivers, day light colour LED lamps, inter connecting wiring with suitable fixing clams, hooks as required including accessories all inclusive.

12

-

-

... More
Supply, erection, testing and commissioning of 3 W LED foot light with cool day light suitable for surface mounting, made out of CRCA powder coated body, aluminium reflectors, poly methyl meth acrylate (PMMA) diffuser, Suitable for fitting including electronic drivers, day light colour LED lamps, inter connecting wiring including accessories all inclusive.

10

-

-

... More
Supply, erection, testing and commissioning of 11 W LED entry / exit light fitting with with self contained battery with a battery autonomy of 30 minutes with cool day light, made out of CRCA powder coated body, aluminium reflectors, poly methyl meth acrylate (PMMA) diffuser, glare free light, suitable for recessed / surface mounting including Sealed maintenance free rechargable batteries with a battery autonomy of 30 minutes, inbuilt battery charger, fuse, test switch, electronic drivers, day light colour LED inter connecting wiring etc., including accessories all inclusive.

18

-

-

... More
Supply and providing 300 mm (12") sweep (light duty) 1400 RPM, AC exhaust fan complete in the provided cutout including interconnection wire.

88

-

-

... More
Supply and providing 450 mm (18") sweep (light duty) 1400 RPM, AC exhaust fan complete in the provided cutout including interconnection wire.

40

-

-

... More
Supply, erection, testing and commissioning of 230 V AC buzzer, 1 module suitable switch board mounting.

13

-

-

... More
Supply, erection, testing and commissioning of 5 W LED type foot lamp suitable for GI module back box.

10

-

-

... More
Supply, installation testing and commissioning of Online 1.0 KVA UPS with 30 minutes SMF battery backup, with 230V, 1 phase input, 230 V single phase output

2

-

-

... More
Supply, installation testing and commissioning of Online 3.0 KVA UPS with 30 minutes SMF battery backup, with 230V, single phase input, 230 V single phase output

2

-

-

... More
Supply, installation testing and commissioning of Online 5.0 KVA UPS with 30 minutes SMF battery backup, with 230V, single phase input, 230 V single phase output

8

-

-

... More
Supply, installation testing and commissioning of Online 10 KVA UPS with 30 minutes SMF battery backup, with 415V, 3 phase input, 230 V single phase output

1

-

-

... More
Supply, erection, testing and commissioning of 6 / 10 W LED mirror light fitting made out of CRCA powder coated body, aluminium reflectors, poly methyl meth acrylate (PMMA) diffuser, glare free light, suitable for recessed / surface mounting electronic drivers, day light / warm white colour LED inter connecting wiring etc., including accessories all inclusive.

21

-

-

... More
Supply, erection, testing and commissioning of 75 W LED professional LED strip light IP 65 with cool day light, incluiding suitable fixing, electronic drivers, day light colour LED lamps, inter connecting wiring including accessories all inclusive.

40

-

-

... More
Supply, erection, testing and commissioning of 1 W LED spot LED light with cool day light, incluiding suitable fixing, electronic drivers, day light colour LED lamps, inter connecting wiring including accessories all inclusive.

40

-

-

... More
Dismantling of existing electrical wiring, light fitting, ceiling fan, AC units, power sockets, Data and telephone sockets and associated wiring and handing over the same to stores etc all incisive.

2

-

-

... More
Dismantling of existing electrical wiring, light fitting, ceiling fan, AC units, power sockets, Data and telephone sockets and associated wiring and handing over the same to stores etc all incisive.

4

-

-

... More
Supply, installation testing and commissioning of Wall fan with 600 mm (24") Sweep, Heavy duty oscillation type propeller fan available with impeller consisting of 3 blades in pedestal & bracket type (wall & column mounted).

36

-

-

... More
Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analogue/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. Two Loop Panel

8

-

-

... More
Supplying, installation, testing & commissioning of repeater panel with 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required.

2

-

-

... More
Supplying, installation, testing & commissioning of intelligent analogue addressable photothermal detector complete with mounting base complete as required.

373

-

-

... More
Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required.

146

-

-

... More
Supplying, installation, testing & commissioning of intelligent addressable programmable sounder complete as required.

58

-

-

... More
Supplying, installation, testing & commissioning of fault isolator complete with base as required.

22

-

-

... More
Supplying, installation, testing & commissioning of addressable fire control module complete as required.

7

-

-

... More
Supplying, installation, testing & commissioning of addressable beam detector with short circuit isolator (inbuilt or separate) complete with emitter and receiver including connections with remote test features etc complete as required.

7

-

-

... More
Supplying, installation, testing & commissioning of intelligent addressable duct detector including suitable Photo detector complete with base as required.

18

-

-

... More
Supplying, installation, testing & commissioning of addressable manual call point complete as required.

68

-

-

... More
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required.

13

-

-

... More
Supplying & laying of 2x1.5 sqmm fire alarm unarmoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required - (a) 2c x 1.5 sq. mm unarmoured cable.

11250

-

-

... More
Supplying, erecting, testing and commissioning of machine room less passenger Elevator having 10 passengers capacity of 680 Kgs, rated speed 1.0 mtr./sec., for GF, plus 1 upper floor, 2 openings, 400 volt 3 phase, 50 Hz, AC variable voltage variable frequency derive with speed encoding, simplex full collective with/with out attendant, microprocessor based controller located top floor, variable frequency regenerative drive, flat polyurethane coated belts for traction media, stainless steel panels with hairline finish for car and door, gearless with permanent magnet motor located in the shaft top, all openings are located at the front of the hoist way, with centre opening Automatic with ACVVVF door operator with electronic door protective system, stainless steel hairline finish sliding doors, painted frame with down light false ceiling, Stainless Steel mirror finish hand rails, granite flooring of client choice, sixteen segment digital LED display position indicator in all floors, digital car position indicator, over load warning indicator, battery operated alarm bell and emergency light, fireman's switch at main lobby, with automatic rescue device, intercom between lift car and lobby and controller, voice synthesizer, 60 minutes fire rated car door. Car Entrance:- Clear opening 900 mm wide x 2100mm high etc., inclusive of all tax and duties

2

-

-

... More
Part 7.Common Infra - External electrical,Street lighting & Power socket

-

-

-

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole and neutral

76

-

-

... More
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps

14

-

-

... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps

14

-

-

... More
Supply, installation, testing commissioning of 415 V, three phase incoming and 230 V single phase outgoing portable power socket suitable for outdoor operation with IP 67 rating, with following Excluding MCB's: (Type - I) Provision for Incommer : 63 Amps 4 pole MCB - 1 no. Provision for outgoing : 32 A SP MCB - 2 nos. 16 A SP MCB - 4 nos. Industrial power socket : 32 A 3 pin socket with plug - 2 nos. 16 A 3 pin socket with plug - 4 nos. The enclosure shall be made out of poly carbonate suitable for outdoor operation with nessary mounting arrangement

10

-

-

... More
Supply, installation, testing commissioning of 415 V, three phase incoming and 230 V single phase outgoing portable power socket suitable for outdoor operation with IP 67 rating, with following Excluding MCB's:(Type - II ) Provision for Incommer : 63 Amps 4 pole MCB - 1 no. Provision for outgoing : 16 A SP MCB - 4 nos. Industrial power socket : 16 A 3 pin socket with plug - 4 nos. The enclosure shall be made out of poly carbonate suitable for outdoor operation with nessary mounting arrangement

4

-

-

... More
Supply, testing and acommissioning of PVC Insulated and PVC Round Sheathed Multi Core Bright Annealed Bare Copper Conductor Heavy Duty Industrial unarmoured Cables for Voltage Grade 1100 Volts as per IS: 694:2010 4 core x 16 sq.mm cable

350

-

-

... More
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required

4

-

-

... More
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)

60

-

-

... More
Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.

55

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 x 16 Sq.mm. AYFY, XLPE, Al, UG cable

162

-

-

... More
Supply and laying of one number additional PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground in the same trench in one tier horizontal formation including widening the trench by 20 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil) 4 core 16 sq mm

2200

-

-

... More
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required - Above 6.5 metre and upto 8.0 metre Each

60

-

-

... More
Design, manufacture, supply, erection, testing and commissioning of 415 V street lighting feeder pillar box suitable for outdoor installation, made up of CRCA sheet steel of thickness not less than 2 mm with a weather proof canopy of top, double door construction, IP 55 protection, anti corrosive chemical resistant paint with 1no. 125 A TPN MCCB with 16 kA breaking capacity in the incoming and 8 nos 25 A, TPN contactor 10 nos. 25 A TPN MCCB, 24 nos, 10A SP MCB as outgoing, automatic dawn and dusk with cyclic timer control for street light outgoing and adequate plate to terminate suitable cable as incomer and suitable cable as outgoing. energy saver for automatic switching ON/OFF as per pre-sets time cycle, digital multifunctional meter with RS485 port and suitable CT etc., including concrete pedestal and associated civil works.

2

-

-

... More
7.50 meter street light pole (410-SP-6) with 1.50 m single arm

60

-

-

... More
Supply and fixing of following LED street light fitting with cool day light, made out of Pressure die cast aluminium body, separate compartment for LED, including electronic drivers, day light colour LED lamps, inter connecting wiring with suitable fixing clams as required including accessories all inclusive - 90 W LED street light fitting

60

-

-

... More
Supplying, installing by suspension on ceiling, testing and commissioning of following capacity Sandwich Type Bus Trunking for use on 3 phase 4 wire 415 volts, 50 Hz A.C. supply with metal clad enclosure made of 1.6mm thick steel sheet duly powder coated in convenient section complete with 4 Nos aluminium bus bars, necessary joints, elbow joints & expansion joints and bends, fire barrier at each floor, provision of tapping at every metre, adopter box and copper flexible for joints, continuous earthing with 2 Nos aluminium strip of suitable size( one on each side) including G.I clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. 1250 amps 50 KA SC for 1 sec

20

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 300 mm width X 50 mm depth X 1.6 mm thickness

40

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 450 mm width X 62.5 mm depth X 2.0 mm thickness

40

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 600 mm width X 62.5 mm depth X 2.0 mm thickness

40

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 900 mm width X 62.5 mm depth X 2.0 mm thickness

20

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 300 mm width X 50 mm depth X 1.6 mm thickness

4

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 450 mm width X 62.5 mm depth X 2.0 mm thickness

4

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 600 mm width X 62.5 mm depth X 2.0 mm thickness

4

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 900 mm width X 62.5 mm depth X 2.0 mm thickness

4

-

-

... More
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required

6

-

-

... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

20

-

-

... More
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)

120

-

-

... More
Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.

240

-

-

... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

800

-

-

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.

1000

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 120 sq. mm and upto 400 sq. mm

600

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ x 25 Sq.mm. AYFY, XLPE, Al, UG cable

32

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ x 35 Sq.mm. AYFY, XLPE, Al, UG cable

10

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ x 70 Sq.mm. AYFY, XLPE, Al, UG cable

4

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ x 95 Sq.mm. AYFY, XLPE, Al, UG cable

4

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ x 120 Sq.mm. AYFY, XLPE, Al, UG cable

2

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ x 240 Sq.mm. AYFY, XLPE, Al, UG cable

6

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ x 300 Sq.mm. AYFY, XLPE, Al, UG cable

18

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 x 10 Sq.mm. AYFY, XLPE, Al, UG cable

10

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 x 16 Sq.mm. AYFY, XLPE, Al, UG cable

20

-

-

... More
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil). 2 core 4 sqmm XLPE Al. Ar. cable

150

-

-

... More
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil). 3 core 4 sqmm XLPE Al. Ar. cable

150

-

-

... More
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil). 3½C x 25 Sq.mm. AYFY, XLPE, Al, UG cable

1260

-

-

... More
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil). 3½C x 35 Sq.mm. AYFY, XLPE, Al, UG cable

280

-

-

... More
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil). 3½C x 70 Sq.mm. AYFY, XLPE, Al, UG cable

285

-

-

... More
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil). 3½C x 95 Sq.mm. AYFY, XLPE, Al, UG cable

660

-

-

... More
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil). 3½C x 120 Sq.mm. AYFY, XLPE, Al, UG cable

195

-

-

... More
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil). 3½C x 185 Sq.mm. AYFY, XLPE, Al, UG cable

355

-

-

... More
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil). 3½C x 240 Sq.mm. AYFY, XLPE, Al, UG cable

320

-

-

... More
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil). 3½C x 300 Sq.mm. AYFY, XLPE, Al, UG cable

415

-

-

... More
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required. 3½C x 25 Sq.mm. AYFY, XLPE, Al, UG cable

30

-

-

... More
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required. 3½C x 35 Sq.mm. AYFY, XLPE, Al, UG cable

30

-

-

... More
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required. 3½C x 70 Sq.mm. AYFY, XLPE, Al, UG cable

50

-

-

... More
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required. 3½C x 95 Sq.mm. AYFY, XLPE, Al, UG cable

50

-

-

... More
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required. 3½C x 120 Sq.mm. AYFY, XLPE, Al, UG cable

60

-

-

... More
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required. 3½C x 185 Sq.mm. AYFY, XLPE, Al, UG cable

40

-

-

... More
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required. 3½C x 240 Sq.mm. AYFY, XLPE, Al, UG cable

60

-

-

... More
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required. 3½C x 300 Sq.mm. AYFY, XLPE, Al, UG cable

60

-

-

... More
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 3½C x 25 Sq.mm. AYFY, XLPE, Al, UG cable

700

-

-

... More
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 3½C x 35 Sq.mm. AYFY, XLPE, Al, UG cable

60

-

-

... More
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 3½C x 70 Sq.mm. AYFY, XLPE, Al, UG cable

30

-

-

... More
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 3½C x 95 Sq.mm. AYFY, XLPE, Al, UG cable

40

-

-

... More
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 3½C x 120 Sq.mm. AYFY, XLPE, Al, UG cable

20

-

-

... More
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 3½C x 185 Sq.mm. AYFY, XLPE, Al, UG cable

100

-

-

... More
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 3½C x 240 Sq.mm. AYFY, XLPE, Al, UG cable

60

-

-

... More
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 3½C x 300 Sq.mm. AYFY, XLPE, Al, UG cable

120

-

-

... More
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 4C x 10 Sq.mm. AYFY, XLPE, Al, UG cable

170

-

-

... More
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 4C x 16 Sq.mm. AYFY, XLPE, Al, UG cable

280

-

-

... More
Supply and laying of one number additional PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground in the same trench in one tier horizontal formation including widening the trench by 20 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil) 4 core 10 sq mm

1320

-

-

... More
Supply and laying of one number additional PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground in the same trench in one tier horizontal formation including widening the trench by 20 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil) 4 core 16 sq mm

120

-

-

... More
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required: 300 sq. mm

7

-

-

... More
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 300 sq. mm

1

-

-

... More
11 kV HT RMU Panel Supply and Installation of Data Acquisition compatible, Extensible, add-on type Ring Main Unit with VCB (Single Switch T-Extension) with motors for remote switching and DA Compatible Design, Engineering, Manufacture, Assembly, Inspection and Testing before supply, Packing and delivery at site, erection, installation, testing & commissioning of 11 kV HT switchgear with all accessories and suitable for installation in three phase, three wire,11 kV, 50 Hz, A.C. distribution network. complete with all accessories erected in the provided foundation complete as per specification and as directed by engineer in charge at site. The RMU shall be complying to KSEB specification. Outdoor type, 11 kV Extensible Ring Main unit (RMU), with 1 No. Vacuum Circuit Breaker in tee OFF the Vacuum Circuit Breaker (VCB) feeder shall Comprise of 1 No. 11 kV, 630A, 18.0 kA, for 3 sec, manual operated VCB 1 No. Common Items, Earth Switch & Accessories for each RMU1 set Operating Handle (Supplied Loose with RMU)The panel shall be suitable for terminating 1 R of 3C x 300 Sq.mm XLPE 11 kV (E) cable

1

-

-

... More
Supply, installation testing commissioning of 11kv Installation of Data Acquisition compatible, Extensible, add-on type Ring Main Unit indoor type with VCB (Single Switch T-Extension) with motors for remote switching and DA Compatible with 1 No. 11 kV, 630A, 26.3 kA, for 3 sec, motor operated VCB1 No. Self Powered 3O/C+1E/F Relay Common Items, Earth Switch & Accessories for each RMU1 set Operating Handle (Supplied Loose with RMU)The panel shall be suitable for terminating 1 R of 3C x 300 Sq.mm XLPE 11 kV (E) cable

1

-

-

... More
Outdoor transformers Supply, erection, testing and commissioning of 11 / 0.433 kV, 800 kVA, copper wound, outdoor distribution transformer, ONAN, DYn11, with Off load tap changer range from +5% to -10% in steps of 2.5% with 6 steps / 7 positions, complete with first oil filled, with suitable cable box for HT side termination and Bus duct in LT side termination complying to IS 2026, including transportation, unloading at site, all control cables between transformer Marshalling box to MV Panel, in the constructed foundation of adequate depth for transformer plinth of height 450 mm above FGL, mounting channelling etc., all inclusive. Specification should meet IS 118o transformer losses level -3.

1

-

-

... More
Supply, erection, testing, commissioning of 400 KVA, 415 V, 3 phase, 50 Hz, DG Set suitable for synchronisation with diesel engine at 1500 RPM coupled with alternator rated at 400 KVA, 415 V, 0.8 PF mounted on a channel Iron base frame, fuel tank of adequate capacity, starting batteries with leads, AMF panel, hospital type silencer, with acoustic enclosure , control panel, inter connecting control cable, cable end termination, including lubrication system, cooling system, all inclusive. DG set should comply with central pollution control board (CPCB) norms as per the latest environment (protection) rules,

2

-

-

... More
Supply, erection, testing, commissioning of auto synchronisation panel suitable for 2nos x 400 KVA, 415 V, 3 phase, 50 Hz, DG Set with CPRI/ERDA tested floor standing, single front, fully compartmentalized, double ended, IEC 60439 compliant, 14 G CRCA sheet steel fabricated IP 42 protected complete as per specification / as per local norms, comprising of the following major switchgear/ devices / components and form-III B form of construction with incomer of 2 nos 630 Amps, 50 kA, 4 pole microprocessor based ACB,and outgoing of 1 no. 1250 Amps, 50 kA, 4 pole microprocessor based ACB, auto synchronising relay, Microprocessor based DG set protection relay with associated control and protection CT of appropriate bourden, electronic energy meter, auto / manual selection for synchronizing.

1

-

-

... More
MV panel Design, supply, assembly, wiring, supply, installation, testing and commissioning of CPRI/ERDA tested floor standing, single front, fully compartmentalized, double ended, IEC 60439 compliant, 14 G CRCA sheet steel fabricated IP 42 protected complete as per specification, comprising of the following major switchgear/ devices / components and form-IIIB form of construction as per SLD. Protection 27, 50, 51, 50N, 51G, 81, 64R & 86 for Transformer Incomer Feeder. Including necessary CT for 51G 27, 50, 51, 50N, 51G, 81 & 86 for Diesel Generator Incomer Feeder. Including necessary CT for 51G Metering Digital multi-function meter with necessary CTs (A, V, kW kWh, kVA, RkVA, PF), with RS 485 communication, Digital energy meter with necessary CTs Power pack with battery backup for ACB operation. AMF relay including auto / manual selection with necessary interconnection and electrical interlock. Indications Cluster type LED indication lamps for 3 phases, ON, OFF, TRIP, local, remote in each of the two-incomer ACB compartments. Busbar 1250A, 50 kA/1 sec., 415 Volts, TPN (100 % neutral), 50 Hz Aluminium bus bars Transformer incomer & Bus coupler 1 No. each of 1250A, FP EDO, ACB, 50 kA with Microprocessor based O/C, S/C & E/F releases with electrical interlock with DG incomer & Bus Coupler DG incomer 1 No. each of 1250A, FP EDO, ACB, 50 kA with Microprocessor based O/C, S/C & E/F releases with electrical interlock with DG set incomer & Bus Coupler Outgoing: 630 A, TPN MCCB 50 kA, - 3 Nos. 400 A, TPN MCCB 50 kA, - 3 Nos. 250 A, TPN MCCB 36 kA, - 10 Nos. 250 A, TPN Isolator 36 kA, - 1 Nos. for Fire pump 125 A, TPN MCCB 25 kA, - 8 Nos.

1

-

-

... More
Sub switch board (SSB) - AT Drishya building Design, supply, assembly, wiring, supply, installation, testing and commissioning of CPRI/ERDA tested floor standing, single front, fully compartmentalized, double ended, IEC 60439 compliant, 14 G CRCA sheet steel fabricated IP 42 protected complete as per specification, comprising of the following major switchgear/ devices / components and form-IIIB form of construction. Metering Digital multi-function meter with necessary CTs (A, V, kW kWh, kVA, RkVA, PF), with RS 485 communication Indications Cluster type LED indication lamps for 3 phases, ON, OFF, TRIP, Busbar 250A, 36 kA/1 sec., 415 Volts, TPN (100 % neutral), 50 Hz Aluminium bus bars Incomer 250 A, TPN MCCB 36 kA, - 1 Nos. with Microprocessor based O/C, S/C & E/F releases Outgoing: 63 A, TPN MCCB 25 kA, - 9 Nos. 32 A, TPN MCCB 25 kA, - 9 Nos.

2

-

-

... More
Sub switch board - at Recording theatre Design, supply, assembly, wiring, supply, installation, testing and commissioning of CPRI/ERDA tested floor standing, single front, fully compartmentalized, double ended, IEC 60439 compliant, 14 G CRCA sheet steel fabricated IP 42 protected complete as per specification, comprising of the following major switchgear/ devices / components and form-IIIB form of construction. Metering Digital multi-function meter with necessary CTs (A, V, kW kWh, kVA, RkVA, PF), with RS 485 communication Indications Cluster type LED indication lamps for 3 phases, ON, OFF, TRIP, Busbar 250A, 36 kA/1 sec., 415 Volts, TPN (100 % neutral), 50 Hz Aluminium bus bars Incomer 250 A, TPN MCCB 36 kA, - 1 Nos. with Microprocessor based O/C, S/C & E/F releases Outgoing: 63 A, TPN MCCB 25 kA, - 8 Nos. 32 A, TPN MCCB 25 kA, - 2 Nos.

1

-

-

... More
Sub switch board - AT Main shooting floor Design, supply, assembly, wiring, supply, installation, testing and commissioning of CPRI/ERDA tested floor standing, single front, fully compartmentalized, double ended, IEC 60439 compliant, 14 G CRCA sheet steel fabricated IP 42 protected complete, AMF relay with necessary control wiring arrangement as per specification, comprising of the following major switchgear/ devices / components and form-IIIB form of construction. Metering Digital multi-function meter with necessary CTs (A, V, kW kWh, kVA, RkVA, PF), with RS 485 communication Indications Cluster type LED indication lamps for 3 phases, ON, OFF, TRIP. Busbar 400A, 36 kA/1 sec., 415 Volts, TPN (100 % neutral), 50 Hz Aluminium bus bars Incomer - 1 400 A, TPN MCCB 36 kA, - 1 Nos. with Microprocessor based O/C, S/C & E/F releases with electrical interlock with EDG incomer EDG Incomer - 2 400 A, TPN MCCB 36 kA, - 1 Nos. with Microprocessor based O/C, S/C & E/F releases with electrical interlock with incomer-1 Power change over Contactor 400 Amps 4 pole change over contact for EB & DG incomer with necessary power pack for AMF relay. Outgoing: 125 A, TPN MCCB 25 kA, - 6 Nos. 63 A, TPN MCCB 25 kA, - 10 Nos. 32 A, TPN MCCB 25 kA, - 2 Nos.

1

-

-

... More
Sub switch board - at DI building Design, supply, assembly, wiring, supply, installation, testing and commissioning of CPRI/ERDA tested floor standing, single front, fully compartmentalized, double ended, IEC 60439 compliant, 14 G CRCA sheet steel fabricated IP 42 protected complete as per specification, comprising of the following major switchgear/ devices / components and form-IIIB form of construction. Metering Digital multi-function meter with necessary CTs (A, V, kW kWh, kVA, RkVA, PF), with RS 485 communication Indications Cluster type LED indication lamps for 3 phases, ON, OFF, TRIP, Busbar 250A, 36 kA/1 sec., 415 Volts, TPN (100 % neutral), 50 Hz Aluminium bus bars Incomer 250 A, TPN MCCB 36 kA, - 1 Nos. with Microprocessor based O/C, S/C & E/F releases Outgoing: 63 A, TPN MCCB 25 kA, - 8 Nos. 32 A, TPN MCCB 25 kA, - 2 Nos.

1

-

-

... More
Sub switch board - at Mini shooting floor Design, supply, assembly, wiring, supply, installation, testing and commissioning of CPRI/ERDA tested floor standing, single front, fully compartmentalized, double ended, IEC 60439 compliant, 14 G CRCA sheet steel fabricated IP 42 protected complete as per specification, comprising of the following major switchgear/ devices / components and form-IIIB form of construction. Metering Digital multi-function meter with necessary CTs (A, V, kW kWh, kVA, RkVA, PF), with RS 485 communication Indications Cluster type LED indication lamps for 3 phases, ON, OFF, TRIP, Busbar 250A, 36 kA/1 sec., 415 Volts, TPN (100 % neutral), 50 Hz Aluminium bus bars Incomer 250 A, TPN MCCB 36 kA, - 1 Nos. with Microprocessor based O/C, S/C & E/F releases Outgoing: 63 A, TPN MCCB 25 kA, - 8 Nos. 32 A, TPN MCCB 25 kA, - 2 Nos.

1

-

-

... More
Sub switch board - at Office BUILDING Design, supply, assembly, wiring, supply, installation, testing and commissioning of CPRI/ERDA tested floor standing, single front, fully compartmentalized, double ended, IEC 60439 compliant, 14 G CRCA sheet steel fabricated IP 42 protected complete as per specification, comprising of the following major switchgear/ devices / components and form-IIIB form of construction. Metering Digital multi-function meter with necessary CTs (A, V, kW kWh, kVA, RkVA, PF), with RS 485 communication Indications Cluster type LED indication lamps for 3 phases, ON, OFF, TRIP, Busbar 250A, 36 kA/1 sec., 415 Volts, TPN (100 % neutral), 50 Hz Aluminium bus bars Incomer 250 A, TPN MCCB 36 kA, - 1 Nos. with Microprocessor based O/C, S/C & E/F releases Outgoing: 63 A, TPN MCCB 25 kA, - 8 Nos. 32 A, TPN MCCB 25 kA, - 2 Nos.

1

-

-

... More
Sub switch board - at Property store Design, supply, assembly, wiring, supply, installation, testing and commissioning of CPRI/ERDA tested floor standing, single front, fully compartmentalized, double ended, IEC 60439 compliant, 14 G CRCA sheet steel fabricated IP 42 protected complete as per specification, comprising of the following major switchgear/ devices / components and form-IIIB form of construction. Metering Digital multi-function meter with necessary CTs (A, V, kW kWh, kVA, RkVA, PF), with RS 485 communication Indications Cluster type LED indication lamps for 3 phases, ON, OFF, TRIP, local, remote in each of the two-incomer ACB compartments. Busbar 125A, 36 kA/1 sec., 415 Volts, TPN (100 % neutral), 50 Hz Aluminium bus bars Incomer 125 A, TPN MCCB 36 kA, - 1 Nos. with Microprocessor based O/C, S/C & E/F releases with electrical interlock with EDG incomer Outgoing: 63 A, TPN MCCB 25 kA, - 6 Nos.

1

-

-

... More
Sub switch board - at L Shaped studio Design, supply, assembly, wiring, supply, installation, testing and commissioning of CPRI/ERDA tested floor standing, single front, fully compartmentalized, double ended, IEC 60439 compliant, 14 G CRCA sheet steel fabricated IP 42 protected complete as per specification, comprising of the following major switchgear/ devices / components and form-IIIB form of construction. Metering Digital multi-function meter with necessary CTs (A, V, kW kWh, kVA, RkVA, PF), with RS 485 communication Indications Cluster type LED indication lamps for 3 phases, ON, OFF, TRIP, local, remote in each of the two-incomer ACB compartments. Busbar 125A, 36 kA/1 sec., 415 Volts, TPN (100 % neutral), 50 Hz Aluminium bus bars Incomer 125 A, TPN MCCB 36 kA, - 1 Nos. with Microprocessor based O/C, S/C & E/F releases with electrical interlock with EDG incomer Outgoing: 63 A, TPN MCCB 25 kA, - 6 Nos.

1

-

-

... More
Sub switch board - at Medium shooting floor Design, supply, assembly, wiring, supply, installation, testing and commissioning of CPRI/ERDA tested floor standing, single front, fully compartmentalized, double ended, IEC 60439 compliant, 14 G CRCA sheet steel fabricated IP 42 protected complete as per specification, comprising of the following major switchgear/ devices / components and form-IIIB form of construction. Metering Digital multi-function meter with necessary CTs (A, V, kW kWh, kVA, RkVA, PF), with RS 485 communication Indications Cluster type LED indication lamps for 3 phases, ON, OFF, TRIP, local, remote in each of the two-incomer ACB compartments. Busbar 125A, 36 kA/1 sec., 415 Volts, TPN (100 % neutral), 50 Hz Aluminium bus bars Incomer 125 A, TPN MCCB 36 kA, - 1 Nos. with Microprocessor based O/C, S/C & E/F releases with electrical interlock with EDG incomer Outgoing: 63 A, TPN MCCB 25 kA, - 6 Nos.

1

-

-

... More
Utility Panel Design, supply, assembly, wiring, supply, installation, testing and commissioning of CPRI/ERDA tested floor standing, single front, fully compartmentalized, double ended, IEC 60439 compliant, 14 G CRCA sheet steel fabricated IP 42 protected complete as per specification, comprising of the following major switchgear/ devices / components and form-IIIB form of construction. Metering Digital multi-function meter with necessary CTs (A, V, kW kWh, kVA, RkVA, PF), with RS 485 communication Indications Cluster type LED indication lamps for 3 phases, ON, OFF, TRIP, local, remote in each of the two-incomer ACB compartments. Busbar 250A, 36 kA/1 sec., 415 Volts, TPN (100 % neutral), 50 Hz Aluminium bus bars Incomer 250A, TPN MCCB 36 kA, - 1 Nos. with Microprocessor based O/C, S/C & E/F releases with electrical interlock with EDG incomer Outgoing: 125 A, TPN MCCB 25 kA, - 4 Nos. 63 A, TPN MCCB 25 kA, - 6Nos. 32 A, TPN MCCB 50 kA, - 4 Nos.

1

-

-

... More
270 KVAr APFC capacitor panel - at substation Supply, installation, testing and commissioning of 270 KVAr Automatic power factor correction panel (APFC) with 10 steps of capacitor switching with 7 % de-tuned filter, cubicle type, free standing, powder coated, 14 G CRCA sheet steel enclosed separate compartment for each capacitor, front operated, indoor type dust & vermin proof, hinged, lockable doors, electrolytic grade aluminium bus bars with SMC /DMC insulator supports, Digital volt meter, Ammeter with selector switch, 10 stage Digital Automatic power factor correction controller, Auto / Manual selector switch, cluster LED type indicators, in the incomer with 630 A, TPN MCCB 50 kA, - 1 Nos. with Microprocessor based O/C, S/C & E/F releases, complete with 480 Volts MPP type Power capacitors, with 3 Nos. 50 KVAr, 4 Nos. 25 KVAr, 1 no. 10 KVAr and 2 nos. 5 KVAR capacitor banks in delta connection, capacitor duty contactors, MCCB’s, timer, start, stop, push buttons, internal wiring, colour coding, ferrules, cable gland plates, Aluminium earth bus for the entire length of the panel with bonding to earth & painting, Panel mounting MS Channels, fasteners, etc., including all associated control wiring and interlocking circuitry, MV panel sensing CT interconnecting wiring etc., all inclusive.

1

-

-

... More
Installation of existing 70 KVAr APFC capacitor panel at Drishya building Installation, testing and commissioning of existing 70 KVAr Automatic power factor correction panel (APFC) including dismantling and re erection of the panel including all nessary accessories and hardware etc., as required all inclusive.

1

-

-

... More
Supply & laying of one number PVC insulated and PVC sheathed armoured copper power cable of 1.1 KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil). 12 core 2.5 sqmm XLPE Cu. Ar. cable.

150

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 2 x 4 Sq.mm. AYFY, XLPE, Al, UG cable

10

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3 x 4 Sq.mm. AYFY, XLPE, Al, UG cable

10

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 12 core 2.5 sqmm XLPE Al. Ar. cable

10

-

-

... More
Supply of one number PVC insulated and PVC sheathed armoured aluminium power cable of 11 KV grade of the following sizes 11kV, 3 core 300 sqmm XLPE Al. Ar. cable

600

-

-

... More
Supplying and laying 50 mm X 6 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)

60

-

-

... More
Supply and Provision of Fire Sealant of HILTI (or) equivalent make at cable penetration Area

40

-

-

... More
11kV Rubber Hand Gloves

4

-

-

... More
11 kV / 415V Caution Board

36

-

-

... More
Shock Treatment chart as per IE Rules (local language must)

6

-

-

... More
Supply, erecting and connecting 4 No. 10 Ltr. capacity Fire Bucket painted with Red oxide outside and White inside with handle at the bottom in a floor mounted angle iron frame with necessary clamps, screws etc. The angle iron frame shall also be painted with Red paint.

1

-

-

... More
Supply and fising of First Aid Box.

6

-

-

... More
22 kV grade synthetic insulation mat,1000 mm x 2.5 mm thickness, compliant to IS with amendment 1 & 2, Class A, CPRI type test certificate required

5

-

-

... More
1.1 kV grade synthetic insulation mat,1000 mm x 2 mm thickness, compliant to IS with amendment 1 & 2, Class A, CPRI type test certificate required

62

-

-

... More
Preparation of drawings and coordination with CEIG / CEA / KSEB for the drawing approval including all necessary assistance to obtain approval,

1

-

-

... More
90 KVAr APFC capacitor panel at Drishya building Supply, installation, testing and commissioning of 90 KVAr Automatic power factor correction panel (APFC) with 8 steps of capacitor switching with 7 % de-tuned filter, cubicle type, free standing, powder coated, 14 G CRCA sheet steel enclosed separate compartment for each capacitor, front operated, indoor type dust & vermin proof, hinged, lockable doors, electrolytic grade aluminium bus bars with SMC /DMC insulator supports, Digital volt meter, Ammeter with selector switch, 8 stage Digital Automatic power factor correction controller, Auto / Manual selector switch, cluster LED type indicators, in the incomer 160 A, TPN MCCB 36 kA, - 1 Nos. with Microprocessor based O/C, S/C & E/F releases, complete with 480 Volts MPP type Power capacitors, with 1 No. 50 KVAr, 1 nos. 25 KVAr, 1 no. 10 KVAr and 1 no. 5 KVAR capacitor banks in delta connection, capacitor duty contactors, MCCB’s, timer, start, stop, push buttons, internal wiring, colour coding, ferrules, cable gland plates, Aluminium earth bus for the entire length of the panel with bonding to earth & painting, Panel mounting MS Channels, fasteners, etc., including all associated control wiring and interlocking circuitry, MV panel sensing CT interconnecting wiring etc., all inclusive.

1

-

-

... More
Supplying and fixing cable route marker made out of precast cement block complying to electricity board regulations including excavation and fixing the same with PCC concrete in ground as required.

100

-

-

... More
Part 8.Common Infra - Lift

-

-

-

... More
Supplying, erecting, testing and commissioning of machine room less passenger Elevator having 10 passengers capacity of 680 Kgs, rated speed 1.0 mtr./sec., for GF, plus 1 upper floor, 2 openings, 400 volt 3 phase, 50 Hz, AC variable voltage variable frequency derive with speed encoding, simplex full collective with/with out attendant, microprocessor based controller located top floor, variable frequency regenerative drive, flat polyurethane coated belts for traction media, stainless steel panels with hairline finish for car and door, gearless with permanent magnet motor located in the shaft top, all openings are located at the front of the hoist way, with centre opening Automatic with ACVVVF door operator with electronic door protective system, stainless steel hairline finish sliding doors, painted frame with down light false ceiling, Stainless Steel mirror finish hand rails, granite flooring of client choice, sixteen segment digital LED display position indicator in all floors, digital car position indicator, over load warning indicator, battery operated alarm bell and emergency light, fireman's switch at main lobby, with automatic rescue device, intercom between lift car and lobby and controller, voice synthesizer, 60 minutes fire rated car door. Car Entrance:- Clear opening 900 mm wide x 2100mm high etc., inclusive of all tax and duties

1

-

-

... More
Supplying, erecting, testing and commissioning of machine room less Goods lift having 1000 kgs capacity, rated speed 0.5 mtr./sec., for GF, plus 1 upper floor, 2 openings, 400 volt 3 phase, 50 Hz, AC variable voltage variable frequency derive with speed encoding, simplex full collective with/with out attendant, microprocessor based controller located top floor, variable frequency regenerative drive, flat polyurethane coated belts for traction media, Mild steel Power coated finish for car and door, gearless with permanent magnet motor located in the shaft top, all openings are located at the front of the hoist way, with centre opening Automatic with ACVVVF door operator with electronic door protective system, Mild steel Power coated sliding doors, painted frame with down light false ceiling, Mild steel Power coated hand rails, chequered plate flooring, sixteen segment digital LED display position indicator in all floors, digital car position indicator, over load warning indicator, battery operated alarm bell and emergency light, fireman's switch at main lobby, with automatic rescue device, intercom between lift car and lobby and controller, voice synthesizer, 60 minutes fire rated car door. Car Entrance:- Clear opening 900 mm wide x 2100mm high etc., inclusive of all tax and duties

1

-

-

... More
Part 9.Common Infra works - Sump,Pumproom,Septic tanks..etc

-

-

-

... More
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.

11324.52

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.

2898.07

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed. Ordinary rock

1581.55

-

-

... More
Excavating trenches of required width for pipes, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then refilling the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :Pipes, exceeding 80 mm dia, but not exceeding 300 mm dia.

199.25

-

-

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.

1049.14

-

-

... More
Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials. Ordinary or hard rock

689.41

-

-

... More
Providing anti termite treatment Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.: With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration

42

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 

242.5

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 

121.94

-

-

... More
Providing and laying in position ready mixed plain cement concrete, with cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of R.M.C. from transit mixer to site of laying and curing, excluding the cost of centering, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per IS:9103 to accelerate/retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge. Note : 1) Excess /less cement used than specified in this item is payable / recoverable separately. M-15 grade plain cement concrete (cement content considered @ 220 kg/cum) 

0.3

-

-

... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level: 1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size 

1.67

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Foundations, footings, bases of columns, etc. for mass concrete

172

-

-

... More
Centering and shuttering including strutting, etc. and removal of form for: Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 

306.85

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for all heights :Suspended floors, roofs, landings, balconies and access platform

654.46

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for all heights :Lintels, beams, plinth beams, girders, bressumers and cantilevers

349.08

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for all heights :Columns, Pillars, Piers, Abutments, Posts and Struts

249.95

-

-

... More
Extra additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5m, for every additional height of 1 metre or part thereof (Plan area to be measured). Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) 

255.59

-

-

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.

32677.81

-

-

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending,placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500

13660.93

-

-

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately). - All works upto plinth level

304.33

-

-

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately).All works above plinth level upto floor V level

71.26

-

-

... More
Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable /recoverable separately. Providing M-30 grade concrete instead of M-25 grade BMC/ RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum)

97.72

-

-

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in plinth Cement Mortar 1:6 (1 cement : 6 coarse sand).

6.04

-

-

... More
Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)

179.69

-

-

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :

46.48

-

-

... More
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand)

24.85

-

-

... More
Providing and fixing ISI marked flush door shutters conforming to IS : 2202(Part I) non-decorative type, core of block board construction with frame of1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters

3.36

-

-

... More
Providing and fixing M.S. grills of required pattern in frames of windows etc.with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.

378.63

-

-

... More
Providing and fixing factory made uPVC white colour fixed glazed windows/ ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), , uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. The rate including Single / double glass panes and silicon sealant . ( The thickness of glass shall be 6mm)

5.22

-

-

... More
Providing and fixing of Wooden FInish UPVC (Unplascticised Poly Vinyl Chloride) three track Sliding Window using 60mm x 37mm outer frame with door Sash of 39 x 75mm frame and all sections shall reinforced with galvanised steel. The Glazed shutters are fixed with 6mm clear float glass fixed with EPDM gasket and co extruded beadings with Espag locking system. The door frame is fixed to the walls using fasteners and to be sealed as external and internal surfaces using weather resistant Silicon sealant of approved make complete as per drawing.

12.81

-

-

... More
Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces 

2.1

-

-

... More
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with rackets,side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.

6.25

-

-

... More
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 

865.91

-

-

... More
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.

710.36

-

-

... More
52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete 

65.99

-

-

... More
Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 

32.76

-

-

... More
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete.

7.2

-

-

... More
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.

38.72

-

-

... More
12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand)

2930.28

-

-

... More
12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand)

71.31

-

-

... More
20 mm cement plaster of mix: 1:4 ( 1 cement : 4 coarse sand)

9

-

-

... More
Ceiling Plastering with CM 1:3, 6mm thick

282.95

-

-

... More
Rough cast plaster upto 10 m height above ground level with a mixture of sand and gravel or crushed stone from 6 mm to 10 mm nominal size, dashed over and including the fresh plaster in two layers, under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand) and top layer 10 mm cement plaster 1:3 (1 cement : 3 fine sand) mixed with 10% finely grounded hydrated lime by volume of cement. - Ordinary cement finish using ordinary cement

192.11

-

-

... More
Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.

25.04

-

-

... More
Pointing on tile brick work with cement mortar 1:3 (1 cement : 3 fine sand): Flush/ Ruled/ Struck or weathered pointing

117.74

-

-

... More
Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) : Flush/ Ruled pointing

22.2

-

-

... More
Finishing walls with water proofing cement paint of required shade: 

522.91

-

-

... More
Distempering with Ist quality acrylic distemper, having VOC (Volatile Organic Compound) content less than 50 grams /litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. 

703.1

-

-

... More
Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture including applying additional coats wherever required, to achieve even shade and colour. 

635.08

-

-

... More
Preparing the surface, providing and applying two coats of Synthetic Enamel paint of approved brand, quality, color etc. as per IS 2932 : 2003 after thoroughly sand papering the surfaces, removing the dust, dirt, repairing & filling dents, holes, cracks etc. over two coats of approved primer as per IS 2074 and one coat of paste filler to wall surfaces including cost of labour, materials, scaffolding, transportation, loading and unloading, tools & plants, all other incidental charges, etc. complete as per drawings, specifications at the following levels and as per the instructions of Engineer-in-Charge. The total painted thickness shall not be less than 100 microns DFT

91.22

-

-

... More
Raking out joints in lime or cement mortar and preparing the surface for re- pointing or re plastering, including disposal of rubbish to the dumping ground within 50 metres lead. 

71.31

-

-

... More
Dismantling and stacking with in 50 metres lead, fencing posts or struts including all earth work and dismantling of concrete etc. in base of : R.C.C. 

305

-

-

... More
Dismantling barbed wire or flexible wire rope in fencing including making rolls and stacking within 50 metres lead. 

856.39

-

-

... More
Fencing with R.C.C. post placed at required distance, embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post one side only, provided with horizontal lines and two diagonals of barbed wire weighing 9.38 kg per 100 metres (minimum), between the two posts fitted and fixed with G.I staples on wooden plugs or G.I binding wire tied to 6 mm bar nibs fixed while casting the post (cost of R.C.C. posts, struts, earth work and concrete to be paid for separately):- Payment to be made per metre cost of total length of barbed wire used . 

28643.09

-

-

... More
Constructing brick masonry circular type manhole 0.91 m internal dia at bottam and 0.56 m dia at to[ in cement mortar 1:4 (1 cement : 4 coarse sand), in side cement plaster 12 mm thick with cement mortar 1:3 ( 1 cement: 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix ( 1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size ), and making necessary channel in cement concrete 1:2:4 ( 1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design: 0.91 m deep with S.F.R.C cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to IS: 12592, total weight of cover and frame to be not less than 182 kg, fixed in cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately): With Sewer bricks conforming to IS:4885 - Circular type manhole upto 0.91 m deep

25

-

-

... More
Constructing brick masonry circular type manhole 0.91 m internal dia at bottam and 0.56 m dia at to[ in cement mortar 1:4 (1 cement : 4 coarse sand), in side cement plaster 12 mm thick with cement mortar 1:3 ( 1 cement: 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix ( 1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size ), and making necessary channel in cement concrete 1:2:4 ( 1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design: 0.91 m deep with S.F.R.C cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to IS: 12592, total weight of cover and frame to be not less than 182 kg, fixed in cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately): With Sewer bricks conforming to IS:4885  -Circular type manhole upto 0.91 m to 1.67 m deep

6.02

-

-

... More
Constructing brick masonry circular manhole 1.22 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 ( 1 cement: 4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 ( 1 cement: 3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 ( 1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design: 1.68 m deep with SFRC cover and frame (heavy duty Hd- 20 grade designation) 560 mm internal diameter conforming to IS: 12592, total weight of cover and frame to be not less than 182 kg fixed in cement concrete 1:2:4 ( 1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. ( Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) With sewer bricks conforming IS:4885 - Circular type manhole 1.22 m internal dia 1.68 m deep

7

-

-

... More
Constructing brick masonry circular manhole 1.22 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 ( 1 cement: 4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 ( 1 cement: 3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 ( 1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design: 1.68 m deep with SFRC cover and frame (heavy duty Hd- 20 grade designation) 560 mm internal diameter conforming to IS: 12592, total weight of cover and frame to be not less than 182 kg fixed in cement concrete 1:2:4 ( 1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. ( Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) With sewer bricks conforming IS:4885 - Circular type manhole 1.22 m internal dia deep beyond 1.68 m to 2.29 m

1.46

-

-

... More
Constructing brick masonry circular manhole 1.52 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement:4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 (1 cement:3 coarse sand: 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size)finished with a floating coat of neat cement, all complete as per standard design: 2.30 m deep with SFRC cover and frame (heavy duty HD - 20 grade designation) 560 mm internal diameter conforming to IS:12592, total weight of cover and frame to be not less than 182 kg fixed in cement concrete 1:2:4 ( 1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately): With sewer bricks conforming IS:4885 - Circular type manhole 1.52 m internal dia 2.30 m deep

2

-

-

... More
Constructing brick masonry circular manhole 1.52 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement:4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 (1 cement:3 coarse sand: 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size)finished with a floating coat of neat cement, all complete as per standard design: 2.30 m deep with SFRC cover and frame (heavy duty HD - 20 grade designation) 560 mm internal diameter conforming to IS:12592, total weight of cover and frame to be not less than 182 kg fixed in cement concrete 1:2:4 ( 1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately): With sewer bricks conforming IS:4885 - Circular type manhole 1.52 m internal dia 2.31 m to 3.30 m deep

0.17

-

-

... More
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786,having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.

556

-

-

... More
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality - MD -10-Square shape 560 mm internal dimensions 

46

-

-

... More
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage. For vertical surface two coats @0.70 kg per sqm

526.74

-

-

... More
Filling with contractor's own earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge 

24.93

-

-

... More
Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete. 

25.14

-

-

... More
Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete

13.99

-

-

... More
Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complet

0.75

-

-

... More
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood 

0.08

-

-

... More
Providing and fixing PVC pipes includes joints of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 110 mm dia 4 Kg/cm2 

14.25

-

-

... More
Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall 

79.2

-

-

... More
Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl

24

-

-

... More
Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m : ordinary rock - depth 1.5m to 3.0m - Pipes, exceeding 80 mm dia, but not exceeding 300 mm dia.

106.7

-

-

... More
Providing drop manhole connection with 160m dia UPVC pipe, PCC 1:2:4 , UPVC specials , and necessary chamber etc complete in all respects as per drawing complying with standard specifications and as directed by departmental officers.

3

-

-

... More
Supplying and laying the 160mm dia dia uPVC pipes class SN 8, SDR-34, confirming to IS 15328-2003 and relevant specials including packing the joints with rubber /lubricant fixing ,holding wherever necessary and making good of the dismantled portion with necessary connections etc., complete in all respects and as per drawing.

306

-

-

... More
Supplying and Laying Mangalore cement concrete tiles over the RCC roof jointed with neat cement slurry mixed with pigment to match the shade of tiles,including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).

99.7

-

-

... More
Providing and fixing 6mm thick fixed glass window with UPVC casing and all necessary fixtures such as gasket, wool strip, Screws etc. complete as directed and approved by engineer incharge

12

-

-

... More
Providing and fixing of precast R.C.C. post / struts / pillars of mix 1:1.5:3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 12.5 mm nominal size ) of requird size with wooden plugs or 6 mm bar nibs ( Cost is inclusive of steel reinforcement , shuttering as per drawing ) wherever required as per direction of Engineer-in-Charge (cost of earth works in excavation, concrete works in foundation to be paid separately) 

62.57

-

-

... More
Supply and spreading garden soil mix to required depth as per design details in the ratio of 2:1:1 (Garden soil, Sand, Manure)

26.69

-

-

... More
Supply Manure - INORGANIC To be applied one month after planting. Supply of Fertilizer (NPK) 15-15-15 (500gms/Sqm)

22.24

-

-

... More
Providing mono rail 3 tonne capacity, Height of Lift - 5 metres, Operation: Through pendant push button station, Long travel: 10.2 m using ISMB 250, Motor: A.C.Sq. CAGE S4 duty, F Class, IP 55, Open geared type bearing mounted assembly, pulley,motor arrangements ..etc complete with all inclusive as directed by engineer - in -charge. Make: Reva Engineering, Avon cranes, W.H. Brady & Co. Ltd., Marris, Indef, Safex, JAPS

1

-

-

... More
Providing and Laying Graded metal stoe 53mm and below complete as per direction of Engineer-in-Charge

40.84

-

-

... More
Carting away the excavated earth/Ordinary rock and depositing the same up to 3 to 5 km with an average lead of 4 km from the site including loading and unloading etc., all complete and as directed by the Engineer in charge

1047.01

-

-

... More
Earthwork excavtion & filling the excavated earth in lowlying area etc complete as directed by the egineer in charge - All kinds of soil

2461.58

-

-

... More
Providing and constructing granite / trap / basalt size stone masonry in foundation with cement mortar 1:6, stone hammer dressed in courses not less than 20cms high, bond stones at two meter apart in each course including cost of materials, labour, curing complete as per specifications.

23.87

-

-

... More
Supply, Installation, testing and commissioning of boom barriers comprising of the following :- 1. New generation road barrier , Boom length upto 7 m 2. Motor type- 24 V DC 3. Usage - Intensive use 4.Protection - IPS4 5. Housing - Galvanized and powder coated with minimum dimension: 1300mm X 330mm X 240mm 6.Adjustable opening/closing speed - 4-8 Sec 7. Max. Absorbed power - 300 W 8.Minimum Torqu - 600Nm 9.Inbuilt encoder for safety 10.Operating temperature - -20 degree to +55 degree 11.Control Panel - To be located horizontally at top portion of the cabinet minimum 915mm above the Barrier foundation for simple and quick maintenance , to be compatible for connecting any access control system including RFID 12.Provision for fixing Flashing LED on top of the cabinet 13.Max. boom length upto 7 Mtr. 14.Boom should be with Strong round Auminium pipe minimum 100mm dia 15. Provision for fixing LED illumination on both side of the boom at middle line. Also with provision of fixing RED reflective adhesive stickers on both side of the boom. 16. Suitable for fixing additional brake away system for the boom. Manual Operation needed in case of power failure. 17.Provision for connecting Push Button switch for open/close. Provision for connection photoelectric cell, one side with an adapter on the cabinet 18.Provision for connecting loop detectors ( The contractor should propse two or three makes, Meeting the spectifications, along with a detailed comparison and submit the same to the engineer incharge for approval, prior to ordering.)

2

-

-

... More
Supply, Installation, testing and commissioning of horizontal centrifugal monobloc pump (The cost should be inclusive for 2 nos (1 working + 1 standby) of capacity 280 LPM each pump and 12 m head each and electric control panel board (operating 1 pump at a time) with cyclic timer, dry run protection, required electrical and control wiring and also including supply and fixing the required butterfly valves including the cost for the required length of pipes for header pipes, discharge pipe from pump up to existing OHT including the cost for the required dismantling joints on either side of the pumps, as per manufacturer specifications alongwith all accessories like common base plate with suction and discharge manifold complete and as directed by the engineer in charge.

2

-

-

... More
Supplying, laying and jointing of HDPE pipe confirming to IS 4984, UV stabilized & anti - microbial fusion welded, having thermal stability for water supply including all fittings, testing of pipes and joints & wastages as per specifications trenching & refilling and testing the pipeline for specified heads and leakages and disinfecting before commissioning complete as per direction of Engineer in charge -25 mm DN, PE 100, PN 10 rating HDPE pipe

2979

-

-

... More
Supplying, laying and jointing of HDPE pipe confirming to IS 4984, UV stabilized & anti - microbial fusion welded, having thermal stability for water supply including all fittings, testing of pipes and joints & wastages as per specifications trenching & refilling and testing the pipeline for specified heads and leakages and disinfecting before commissioning complete as per direction of Engineer in charge - 32 mm DN, PE 100, PN 10 rating HDPE pipe

303

-

-

... More
Supplying, laying and jointing of HDPE pipe confirming to IS 4984, UV stabilized & anti - microbial fusion welded, having thermal stability for water supply including all fittings, testing of pipes and joints & wastages as per specifications trenching & refilling and testing the pipeline for specified heads and leakages and disinfecting before commissioning complete as per direction of Engineer in charge -40 mm DN, PE 100, PN 10 rating HDPE pipe

225

-

-

... More
Supplying, laying and jointing of HDPE pipe confirming to IS 4984, UV stabilized & anti - microbial fusion welded, having thermal stability for water supply including all fittings, testing of pipes and joints & wastages as per specifications trenching & refilling and testing the pipeline for specified heads and leakages and disinfecting before commissioning complete as per direction of Engineer in charge - 63 mm DN, PE 100, PN 10 rating HDPE pipe

390

-

-

... More
Supplying, laying and jointing of HDPE pipe confirming to IS 4984, UV stabilized & anti - microbial fusion welded, having thermal stability for water supply including all fittings, testing of pipes and joints & wastages as per specifications trenching & refilling and testing the pipeline for specified heads and leakages and disinfecting before commissioning complete as per direction of Engineer in charge - 75 mm DN, PE 100, PN 10 rating HDPE pipe

106

-

-

... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :  25 mm nominal bore 

38

-

-

... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 32 mm nominal bore 

6

-

-

... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 40 mm nominal bore 

4

-

-

... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 65 mm nominal bore 

11

-

-

... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 80 mm nominal bore 

2

-

-

... More
Supplying and fixing of C.I surface box with covers for sluice valves as per IS: 3950 alongwith necessary accessories of approved quality as per direction of Engineer In Charge - 810 mm x 550 mm x 170 mm

28

-

-

... More
Supplying and fixing of 25mm dia pressure reducing valve of approved quality for reducing the downstream pressure along the water distribution line alongwith necessary jointing materials, gaskets, bolts, nuts inclusive of dismantling pieces, washers etc. as per direction of Engineer in charge - 25mm dia pressure reducing valve

12

-

-

... More
Constructing thrust block in R.C.C. 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 nominal size) for HDPE pipeline along the downstream of OHT and including the base concrete 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) with necessary excavation including required reinforcement, centering and shuttering, strutting, propping etc. and removal of form for the sizes as below as per the drawing and as per direction of Engineer in charge - Thrust block Size - 0.3 m x 0.3 m x 1.0 m (2 Nos each for potable and raw water distributionnetwork)

4

-

-

... More
Providing and laying RCC NP3 pipe including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete as per direction of Engineer In Charge - 800 mm inner diameter RCC NP3 pipe for road crossing

53

-

-

... More
Providing and laying RCC NP3 pipe including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete as per direction of Engineer In Charge - 100 mm inner diameter RCC NP3 pipe for road crossing

45

-

-

... More
Supply, Installation, testing and commissioning of horizontal submersible pump (The cost should be inclusive for 2 nos (1 working + 1 standby) of capacity 225 LPM each pump and 54 m head each and electric control panel board (operating 1 pump at a time) with cyclic timer, dry run protection, required electrical and control wiring and also including supply and fixing the required butterfly valves, non return valves, pressure gauge at each pump outlet of 150mm dial, 1/2" NPTM bottom connection, measuring element 316 SS diaphragm suitable to measure the discharge header pressure & pump discharge line pressure (0 to 10 kg/Sq.cm) etc including the cost for the required length of pipes for header pipes, discharge pipes for each pump and for common discharge pipes and including the cost for the required dismantling joints on either side of the pumps, as per manufacturer specifications alongwith all accessories like common base plate with suction and discharge manifold complete and as directed by the engineer in charge.

2

-

-

... More
Supplying, laying and jointing of HDPE pipe confirming to IS 4984, UV stabilized & anti - microbial fusion welded, having thermal stability for water supply including all fittings, testing of pipes and joints & wastages as per specifications trenching & refilling and testing the pipeline for specified heads and leakages and disinfecting before commissioning complete as per direction of Engineer in charge - 110 mm DN, PE 100, PN10 rating HDPE pipe

787

-

-

... More
Supplying and fixing of double orifice kinetic air valve with isolating sluice valve confirming to IS 14845 damper proof design (PN 10 rating) of approved quality with all jointing materials, gaskets, bolts, nuts, inclusive of dismantling pieces, washers, rubber gaskets as per IS:638 etc. complete as per direction of Engineer in charge - 40 mm valve for upto 100 mm dia pipe

1

-

-

... More
Constructing thrust block in R.C.C. 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 nominal size) for HDPE pipeline and including the base concrete 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) with necessary excavation including required reinforcement, centering and shuttering, strutting, propping etc. and removal of form for the sizes as below as per the drawing and as per direction of Engineer in charge - Size of 0.3 m x 0.3 m x 1.0 m

14

-

-

... More
Drilling of Bore wells including transportation from one place to another in all strata by first taking a pilot bore of 140 mm /150 mm dia and then enlarging to required dia direct or reverse rotary rigs, including side pankings, disinfections, soil sample tests, water quality test, cost of fuel, labour and drilling and water required for drilling at site including construction of mud pit etc complete as per direction of engineer in charge (For 2 borewell locations) - Drilling of 140 / 150 mm pilot bore - up to 50 m depth ending below ground level

100

-

-

... More
Drilling of Bore wells including transportation from one place to another in all strata by first taking a pilot bore of 140 mm /150 mm dia and then enlarging to required dia direct or reverse rotary rigs, including side pankings, disinfections, soil sample tests, water quality test, cost of fuel, labour and drilling and water required for drilling at site including construction of mud pit etc complete as per direction of engineer in charge (For 2 borewell locations) - Reaming 140/150 mm dia pilot bore to 300 mm dia bore - Up to 50 m depth ending below ground level

100

-

-

... More
Drilling of Bore wells including transportation from one place to another in all strata by first taking a pilot bore of 140 mm /150 mm dia and then enlarging to required dia direct or reverse rotary rigs, including side pankings, disinfections, soil sample tests, water quality test, cost of fuel, labour and drilling and water required for drilling at site including construction of mud pit etc complete as per direction of engineer in charge (For 2 borewell locations) - Reaming 300 mm dia, bore to 400 mm / 450 mm dia bore -Up to 50 m depth ending below ground level

100

-

-

... More
Supply, delivery of pipes at site and labour charges for inserting 200 mm dia PVC Casing pipes assemble (with slots or without slots) in the drilled bore holes including jointing the pipes either with PVC Couplers with Cement paste or jointing the pipes with threaded sockets etc., complete supply and packing the annular space with pebbles of size and quality as approved by the Engineer in charge.

100

-

-

... More
Charges for developing the Bore well with air compressor of 600 CFM capacity (minimum 8 Hours) till a clear water comes from the bore well without any silt or mud mixes, including the cost required for transportation of the compressor, labour and fuel charges for compressor as directed by Engineer in charge and conducting yield test by 'V' notch method. (For 2 borewell locations)

16

-

-

... More
Supplying, laying and jointing of 110 mm OD Unplasticised PVC column pipes 10 kg/cm² conforming to IS 4985-2000 or ASTM D 1785 (Diameter of pipes and pressure head as relevent to IS 4985), all uPVC pipe, including jointing of pipes with sure-loc joints or threaded joints & threaded fittings, testing of joints complete as per direction of Engineer in Charge. (Bore well pump outlet up to ground level) - 110mm OD uPVC pipe

100

-

-

... More
Supply, installation testing & commissioning of horizontal submersible pump for borewell of capacity 280 LPM each pump and 124 m head each (approximately 15 HP pump set) alongwith non return valves, pressure gauge including cable 3 C, 4 sq.mm copper conducter pvc insulated cable suitable for submersible pump set operation and with manufacturer's standard control panel board which is mandatory and other required supporting items like SS hose nipple, nylon rope, clamps, bolt and nuts, GI nipple, 40 mm dia HDPE hose of required length etc including all accessories complete as directed by the engineer in charge - Horizontal submersible pump - 280 LPM each pump and 124 m head

2

-

-

... More
Supplying, laying and jointing of HDPE pipe confirming to IS 4984, UV stabilized & anti - microbial fusion welded, having thermal stability for water supply including all fittings, testing of pipes and joints & wastages as per specifications trenching & refilling and testing the pipeline for specified heads and leakages and disinfecting before commissioning complete as per direction of Engineer in charge - 140 mm DN, PE 100, PN16 rating HDPE pipe - Pumping main from borewell to existing pond

964

-

-

... More
Supplying and fixing of C.I Ball valve / Sluice valve with bolted bonnet, inside screw, non rising spindle, conforming to IS : 14846 (Slucie valve) / ASTM A105 (Ball valve) etc. complete as per direction of Engineer in Charge - 100mm diameter

2

-

-

... More
Supplying and fixing of double orifice kinetic air valve with isolating sluice valve confirming to IS 14845 damper proof design (PN 10 rating) of approved quality with all jointing materials, gaskets, bolts, nuts, inclusive of dismantling pieces, washers, rubber gaskets as per IS:638 etc. complete as per direction of Engineer in charge - 40 mm valve for upto 100 mm dia pipe, rating 10kg/sq.cm

2

-

-

... More
Supplying and fixing C.I. dirt box strainer in between bore well pump & valve with necessary nuts, bolts, rubber insertions etc conforming to IS : 2373, complete and as directed by the Engineer in charge - 100 mm dia dirt box strainer

2

-

-

... More
Supply, delivery and installation of 63 mm diameter Woltmann type MID certified water meters suitable for all positions with IP68 protection mechanism suitable for potable water with very low head loss, internally and externally E/P powder painted with optical reading facility, capable to operate at a maximum working temperature of 50° C and maximum working pressure of 16 bar, supply should include all necessary bolts, nuts, rubber, AMR units, collector units & RS 485 cable and other accessories required for erection, testing and commisioning.

2

-

-

... More
Providing and construction of 600 x 600 x 450 mm size chamber with brick work in cement mortar 1:5 (1 cement & 5 coarse sand), with precast removable cover slab of size 1.06 m x 1.06 m & 40 mm thick, with necessary excavation in all types of soil except hard rock requiring blasting including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m including sand filling below foundation concrete, foundation concrete in 1:4:8 (1 cement : 4 fine sand : 8 graded stone aggregate 40 mm nominal size) and inside & outside plastering with cement mortar 1:5 (1 cement-OPC 43 grade : 5 coarse sand) 12 mm thick for brick work, finished with a floating coat of neat cement etc. complete as per drawing and as per direction of Engineer in charge.

2

-

-

... More
Providing and constructing bed block in cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 nominal size) for HDPE pipeline with necessary excavation in all types of soil except hard rock including shoring, centering and shuttering, strutting, propping & curing concrete etc. as per the drawing and as per direction of Engineer in charge - Size of 0.20 m x 0.20 m x 0.15 m

10

-

-

... More
Providing and laying 300 mm dia NP-3 class R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete as per direction of Engineer in charge.

12

-

-

... More
Supply, installation, testing, commissioning of Recommended Make 2MP IP Dome Camera indoor type of Recommended Make including necessary mounting clamps and appropriate accessories as required for satisfactory completion

38

-

-

... More
Supply, installation, testing, commissioning of Recommended Make 2MP IP Pan Tilt Zoom (PTZ) Camera with Bracket outdoor type of Recommended Make including panel tilt mechanism, necessary mounting clamps and appropriate accessories as required for satisfactory completion

5

-

-

... More
Supply, installation, testing, commissioning of Recommended Make 2MP IR IP H.265 Bullet camera with 2.8 to 12mm Motorized Lens, POE, SD card slot, WDR, Smart Analytics and 50M IR support, suitable IP65 enclosure for outdoor operation all-inclusive for satisfactory completion

9

-

-

... More
Supply, installation, testing, commissioning of Recommended Make 64 Channel NVR including all accessories as required for satisfactory completion

1

-

-

... More
Supply, installation, testing, commissioning of Recommended Make 32 Channel NVR including all accessories as required for satisfactory completion

1

-

-

... More
Supply, installation, testing, commissioning of Recommended Make 6TB HDD including all accessories as required for satisfactory completion

5

-

-

... More
Supply and fixing of 15U wall mount rack with tray and cable manager including all accessories as required for satisfactory completion

2

-

-

... More
Supply and fixing of 6U wall mount rack with tray and cable manager including all accessories as required for satisfactory completion

6

-

-

... More
Supply, erection of ABS Plastic junction boxes of size 150 x 150 x 75 mm suitable for out door operation with IP 65, weather proof, including 8 way 16 amps connectors cable entry hole as required with necessary mounting accessories as required.

52

-

-

... More
Supply, installation, testing, commissioning of Recommended Make 8 Port POE Switch with SFP Module

2

-

-

... More
Supply, installation, testing, commissioning of Recommended Make 24 Port POE Switch with SFP Module

3

-

-

... More
Supply, installation, testing, commissioning of approved Make Outdoor camera Pole with fixing

14

-

-

... More
Supply and laying of Category 6 U/UTP 4 Pair 23AWG Cable with suitable PVC Conduit

950

-

-

... More
Supply and laying of Category 6 U/UTP 4 Pair 23AWG armoured Outdoor cable.

1725

-

-

... More
Supply, installation, testing, commissioning of Recommended Make 24 Port Patch Panel

3

-

-

... More
Supply, installation, testing, commissioning of Recommended Make Patch Chord 1 M

52

-

-

... More
Supply, laying, testing, commissioning of Recommended Make 6 Core Multimode OFC Cable with required end splicing, and termination and OFC to RS 485 converters etc., as required laid in suitable surface / concealed PVC conduit as required including all accessories as required.

1725

-

-

... More
Supply, installation, testing, commissioning of Recommended Make 6 Port Loaded LIU

4

-

-

... More
Supply, installation, testing, commissioning of Recommended Make 12 Port Loaded LIU

5

-

-

... More
Supply, fixing of Recommended Make Patch Cord - Multimode

6

-

-

... More
Supply installation testing and commissioning of 55" LED Ultra HD display with necessary mounting arrangements

2

-

-

... More
Supply, erection, testing and commissioning the Single lane - Dual Point Automatic Number Plate Recognition (ANPR) System. The ANPR kit should consist of one ANPR camera plus one overview cameras (Over view camera covered under CCTV system). Following ANPR kit Features and Technical Specifications are only indicative, better features and specifications shall be provided at the time of equipment supply without any additional cost. Desired ANPR camera Features: • Captures images of vehicles travelling at high speed • 24 hour round the clock operation . Real-time Detection . Number Plate Recording as (1) Images (2) Database . Reports for (1) Entry / Exit Times (2) Frequency of Visits (3) Lean/ Peak time analysis . Black List / White lists Overstay Parking Alert • High accuracy (99%) • Logs vehicles with multiple overview camera images • 1/3" progressive scan sensor • Resolution : 2MP or better • Powerful 5-50 mm lens • IP66 and superior performance for outdoor applications • True WDR technology • In-built IR Illuminator, Average life of illuminator to be 10 yrs approx. • Global Electronic Shutter • ANPR Management system software The ANPR camera should captures the images of vehicle number plates from moving vehicles in both day and night time conditions (even when the vehicle headlights are switched on, the IR lights located beneath the housing to illuminate the registration plate without blinding the driver).

1

-

-

... More
Supply, installation, testing, commissioning of Accessories

1

-

-

... More
Charges towards Testing & Commissioning of CCTV system

1

-

-

... More
Supplying & Drawing unarmoured PVC insulated and & PVC sheathed copper conductor Telephone Pair Cable conforming to ITD specification for indoor application through the existing conduit 2 pair

500

-

-

... More
Supplying & Drawing unarmoured PVC insulated and & PVC sheathed copper conductor Telephone Pair Cable conforming to ITD specification for indoor application through the existing conduit 10 pair

300

-

-

... More
Supply installation testing and commissioning of EPBAX system with following configuration: The system shall be provided with 48 nos analogue extensions, 8 nos trunk incoming. The system should be suitable for expandable up to 240 analogue / digital / IP phones, 8 PRI ports, with add on modules, 19” Rack Mount with 4U Enclosure suitable for wall mounting, operating with 100-240 V AC, 47-60Hz, 48V DC, +20%-15%. Model : Matrix GENX 12 S / equivalent

1

-

-

... More
Supply, laying of Solid polyethylene insulated Jelly filled armoured copper telecom cable, of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil). 5 pair armoured UG cable

500

-

-

... More
Supply, laying of Solid polyethylene insulated Jelly filled armoured copper telecom cable, of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil). 20 pair armoured UG cable

300

-

-

... More
Supply, laying of Solid polyethylene insulated Jelly filled armoured copper telecom cable, of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil). 50 pair armoured UG cable

100

-

-

... More
Supply, installation testing and commissioning of krone box of following pair of cable including all fixing accessories as required. 10 pair krone box

10

-

-

... More
Supply, installation testing and commissioning of krone box of following pair of cable including all fixing accessories as required. 20 pair krone box

4

-

-

... More
Supply, installation testing and commissioning of krone box of following pair of cable including all fixing accessories as required. 50 pair krone box

2

-

-

... More
Supply installation, testing and commissioning of Caller Id Landline phone Set, 30 Incoming and 5 outgoing memory, 2 Level ringer volume switch, Mute option, Redial, call back Real-time clock with year, date and month display Set includes one base unit, one handset, one main line cord and one coil cord

45

-

-

... More
Providing and fixing stainless steel (Grade 304) Post / Frame for external signage made hollow tubes, Channels, Plates etc., including welding, grinding, buffing, polishing and making curvature ( Wherever required) as per approved design and fitting the same with necessary stainless steel nuts and bolts complete, fixing the post in cement concrete 1:2:4( 1 cement : 2 Coarse sand : 4 HBG 20 mm size ) with suitable arrangement as per approval of Engineer in charge ( The rate including cost of all materials, Labours, HOM and Transport charges etc., complete )

20.79

-

-

... More
Providing and applying tack coat with bitumen emulsion conforming to IS: 8887, using emulsion pressure distributer including preparing the surface & cleaning with mechanical broom. with rapid setting bitumen emulsion : On bituminous surface @ 0.25 kg /sqm br

6403.75

-

-

... More
Providing, laying and rolling of close-grade premix surfacing material of 20mm thickness composed of 11.2mm to 0.09mm (Type-A) aggregates using penetration grade bitumen using V-30 to the required line, and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant , laying and rolling with a smooth wheeled roller 8-10 tonne Capacity, and finishing to required level and grade

6403.75

-

-

... More
Excavation for road work in soil with hydraulic excavator of 0.3cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location within all lifts and lead up to 1000m

1652.23

-

-

... More
Cleaning jungle including uprooting of rank vegetation grass brush wood, trees and sapling of girth up to 30cm measured at a height of 1m above ground level and removal of rubbish up to a distance of 50m outside the periphery of the area cleared

1430

-

-

... More
Stepped earth cutting on both sides New workshop building area including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location within all lifts and lead up to 1000m

1704.5

-

-

... More
Construction of granular sub-base by providing graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401 - Grading-IV- For lower sub base - Mix in place Method

512.14

-

-

... More
Providing, laying spreading and compacting graded stone aggregate to Wet Mix Macadam specification 0including premixing the material with water at OMC in mechanical mix plant carriage of mixed material by tipper to site, laying in uniform layers with paver in sub -base/ base course on well prepared surface and compacting with vibratory roller to achieve the desired density.

682.85

-

-

... More
Providing and applying primer coat with bitumen emulsion (SS) on prepared surface of granular base including clearing of road surface and spraying primer at the rate of 0.70-1.0 kg /sqm using mechanical means.

3414.25

-

-

... More
Providing and applying tack coat with bitumen emulsion conforming to IS: 8887, using emulsion pressure distributer including preparing the surface & cleaning with mechanical broom. with rapid setting bitumen emulsion : On bituminous surface @ 0.25 kg /sqm

3414.25

-

-

... More
Close Graded Premix Surfacing / Mixed Seal Surfacing :Providing, laying and rolling of close-grade premix surfacing material of 20mm thickness composed of 11.2mm to 0.09mm (Type-A) aggregates using penetration grade bitumen using V-30 to the required line and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant , laying and rolling with a smooth wheeled roller 8-10 tonne Capacity, and finishing to required level and grade

3414.25

-

-

... More
Maintenance of earth shoulder (stripping excess soil ) from the shoulder surface to achieve the approved level and compacting with plate compactor

2980

-

-

... More
Excavation for roadwork in soil with hydraulic excavator of 0.9cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirement of lines, grades and cross sections, and transporting to the embankment location within all lifts and lead up to 1000m

435.6

-

-

... More
Construction of granular sub-base by providing graded Material, Mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 - Grading I- Plant Mix Method

220

-

-

... More
Construction of granular sub-base by providing graded Material, Mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 - Grading I- Plant Mix Method

1100

-

-

... More
Plain/Reinforced Cement concrete in open foundation complete RCC Grade M20- Using Concrete Mixer - (Without Formwork)

17.6

-

-

... More
Plain/Reinforced cement concrete in open foundation complete - P.C.C Grade M20

26.88

-

-

... More
Supply, Fitting and placing un-coated HYSD bar Reinforcement in foundation complete

0.15

-

-

... More
Part 10. Firefighting - Network

-

-

-

... More
Supplying, erecting, testing and commissioning fire hydrant pump Horizontal Centrifugal End Suction capable of delivering 2850 lpm at 50 mtr head complete with adequate HP automatic diesel engine driven pumps having the residential silencer system and other accessories fuel tank, necessary cooling system .

1

-

-

... More
Supply, erection, testing and commissioning of single stage Horizontal centrifugal End Suction pumps, of approved make for giving discharge of 2850 lpm at a pressure of 50 mtr directly coupled to suitable TEFC motor to operate 400/440 volts 3 phase 50 cycles AC supply with a terminal box suitable for the reception of power cable termination common base plate, necessary foundation bolts.

2

-

-

... More
Supply, erection, testing and commissioning of centrifugal Jockey Pump of approved make, which gives a discharge of 180 lpm at 50 mtr head, with suitable electrical driven motor directly coupled to suitable HP TEFC motor to operate 400/440 volts 3 phase 50 cycles AC supply with a terminal box suitable for the reception of power cable termination common base plate, necessary foundation bolts.

1

-

-

... More
Supply, storing, erection, testing and commissioning of automatic motor control panel comprising generally of the following and fabricated as per specification a. Incoming TPN SFU with fuses b. Aluminum bus bar as per specification c. TPN MCCB outgoing leader with fuses for jockey pumps d. TPN MCCB outgoing feeder for main electric pump e. Voltmeter 96mm (0-500 V ) with selector switch and protection fuses for incomer f. Starter for jockey pump with single phase preventor, automatic pressure switch starting arrangement indicating lamps, fuses and resistors g. Starter for main electric pump with motor protection relay selector switches, ammeters, CTS, Jockey pump and automatic pressure switch starting arrangement , MCBs for control circuits (Hydrant). i. Audio visual alarm system and necessary indicating lamps. j. Minimum length of 500mm required for cable termination.

1

-

-

... More
Supply, storing, erection, testing and commissioning of wall mounted 24 volts control panel to start the fire pump engine automatically as per the following sequence of operation and the auxiliary arrangements a. Engine to start automatically in case of low water pressure secured by the pressure switch with necessary timers relays etc b. Manual stopping c. Audio visual alarm for fault d. Low fuel oil level e. Engine lover speed f. High water temperature g. Low type oil pressure h. Engine false to start i. A battery charger with trickle / Boost arrangements with secondary side tapping at 28, 30,32 and 34 volts equipped with silicon diodes to charge the starting battery of the diesel engine

1

-

-

... More
Supply, fixing, and commissioning of Butterfly Valves as per IS 780/Gate valve as per with flanged ends. The valve has to be fixed using bolts , nuts , washer & rubber gasket - 200mm dia

15

-

-

... More
Supply, fixing, and commissioning of Butterfly Valves as per IS 780/Gate valve as per with flanged ends. The valve has to be fixed using bolts , nuts , washer & rubber gasket - 150mm dia

3

-

-

... More
Supply, fixing, and commissioning of Butterfly Valves as per IS 780/Gate valve as per with flanged ends. The valve has to be fixed using bolts , nuts , washer & rubber gasket - 100mm dia

2

-

-

... More
Supply, fixing, testing and commissioning of gun metal Ball valves with wheel complete as required - 50mm dia

4

-

-

... More
Supply, fixing, testing and commissioning of Non-return valve(Water Check valves) as per IS 5132 complete with hand wheel, companion flange, nuts, gaskets, bolts etc complete as required - 150mm dia

5

-

-

... More
Providing & Fixing Y-Strainer GI complete with stainless steel bucket having 0.3mm perforation, flanged ends, filteration area 1:4,PN 16 rating, complete etc. - 150mm dia

4

-

-

... More
Providing & Fixing Y-Strainer GI complete with stainless steel bucket having 0.3mm perforation, flanged ends, filteration area 1:4,PN 16 rating, complete etc. 200mm dia

1

-

-

... More
Test array arrangement for pumpset with pressure gauge & Pressure Switch , valves etc - Pressure Gauge

6

-

-

... More
Supply, fixing, testing and commissioning of air vessel tank of size 300mm dia x 1000mm long with necessary inlets, outlets, etc complete as per detailed specifications.

1

-

-

... More
FIRE BRIGADE INLET CONNECTION - a. 63mm dia Gun metal instantaneous 4 way inlet arranged on a 150mm dia GI header with flanges & b. 1 no. 150mm Butterfly Valve for hydrant system

1

-

-

... More
Supply, erection, testing and commissioning of heavy C class MS pipes . The pipes being fixed on to the wall or suspended from the ceiling / truss with angle iron supports complete with bends, tees, flanges and with all other required accessories including painting of the pipeline with two coats of approved enamel paint over a coat of primer etc complete (Above Ground) - 150mm dia

795

-

-

... More
Supply, erect, jointing, testing and commissioning MS Heavy C class in trenches (1 Mtrs below ground level). Rate quoted shall include for necessary specials like long radius bends, tees including cutting, welding, flanged joints with necessary washers, nuts, bolts etc. Rate quoted shall also include for providing anticorrosive treatment as per specification. Including cost for excavation & refilling. (Under Ground ) - 150mm dia

24

-

-

... More
Supply and installation of Cast Iron Butterfly valve including making flanged joints by providing necessary nuts, bolts, gaskets(1.5 mm CAF)etc. All complete as per specification.

2

-

-

... More
Supply and installation of Cast Iron Non - Return Valve including making flanged joints by providing necessary nuts, bolts, gaskets etc. All complete as per specification.

1

-

-

... More
Providing pipe support wall with necessary PCC, CC and "C" channels as per drawing.

277

-

-

... More
Supply, fixing, testing and commissioning of Yard Hydrant (PN 16) system with 63 mm dia single head landing valve (Stainless Steel)

34

-

-

... More
Supply, fixing, testing and commissioning of Yard Hydrant (PN 16) system with Hose pipe 63 mm dia 15 m.long with male and female coupling at both ends

68

-

-

... More
Supply, fixing, testing and commissioning of Yard Hydrant (PN 16) system with Branch pipe 63 mm dia with 20 mm (nominal internal diameter) nozzle and suitable for instaneous connection

34

-

-

... More
Supply, fixing, testing and commissioning of Yard Hydrant (PN 16) system with Pre fabricated weather proof lockable cabinet of size not less than 0.75 x 0.6 x 0.25 mtr made out of MS sheet of 16 gauge thickness having central opening and 4 mm thick glazed glass doors (Two No.) suitably marked on the outside with the letters "FIRE HOSE" including necessary locking arrangement and shall be painted with one coat of primer and two coats of synthetic enamel paint of approved shade.

34

-

-

... More
Supply, fixing, testing and commissioning of lever operated slim seal butterfly valves as per detailed specifications complete with Tamper switch, companion flange, nuts, gaskets, bolts etc complete as required - 150mm dia

34

-

-

... More
Supply, erection, testing and commissioning of heavy C class MS pipes . The pipes being fixed on to the wall or suspended from the ceiling / truss with angle iron supports complete with bends, tees, flanges and with all other required accessories including painting of the pipeline with two coats of approved enamel paint over a coat of primer etc complete (Above Ground) - 250mm dia

1491

-

-

... More
Supply, erection, testing and commissioning of heavy C class MS pipes . The pipes being fixed on to the wall or suspended from the ceiling / truss with angle iron supports complete with bends, tees, flanges and with all other required accessories including painting of the pipeline with two coats of approved enamel paint over a coat of primer etc complete (Above Ground) - 80mm dia

68

-

-

... More
Providing, Laying, Testing and commissioning of 250 mm dia RCC pipes of NP3 class hume pipes

64

-

-

... More
Sprinkler System - Supply, erection, testing and commissioning of C class GI pipes . The pipes being fixed on to the wall or suspended from the ceiling / truss with angle iron supports complete with bends, tees, flanges and with all other required accessories including painting of the pipeline with two coats of approved enamel paint over a coat of primer etc complete - 150mm dia

516.6

-

-

... More
Fire License

1

-

-

... More
Supply, Installation, Testing & Commissioning of 4 Kg Capacity of ABC type fire extinguisher fixing on the floor with suitable fixture.

2

-

-

... More
Supply, Installation, Testing & Commissioning of 4.5 Kg capacity of CO2 type fire extinguisher fixing on the floor with suitable fixture.

8

-

-

... More
Part 11.Common Infra works - Furniture,Equipment, Biometric & Mini truck ( The contractor should propse two or three makes, Meeting the spectifications, along with a detailed comparison and submit the same to the engineer incharge for approval, prior to ordering.)

-

-

-

... More
Supply of office table (wooden top) of size 48" (width) x 24" (depth) x 30" (height) with three drawers on one side. Table support leg and three drawer with lock are to be made of metal. Table top Made of 18 mm pre-laminated board duly sealed with 2 mm PVC beading on all sides. Shall have single drawer unit on right side made of 0.5 mm thick prime quality CRCA MS sheet with overall size 355.5 (W) x 559 (D) x 433.5 (H) mm in three drawer option. ( The contractor should propse two or three makes, Meeting the spectifications, along with a detailed comparison and submit the same to the engineer incharge for approval, prior to ordering.)

2

-

-

... More
Supply of office use cane chair without arms: Seat and back are made from seasoned wood, caned (which blends of high and low density polyethylene) and finished with synthetic paint (Colour: Black). seat/back assembly Back size: 380 mm (W) x 400 mm (H) Seat size: 380 mm (W) x 425 mm (D) cane for seat/back, should have blends of high and low density polyethylene. cane strength The under structure assembly should be a cantilever type frame made of diameter 25.4 mm x2 mm thick MS ERW tube and powder coated (DFT 40-60 microns) ( The contractor should propse two or three makes, Meeting the spectifications, along with a detailed comparison and submit the same to the engineer incharge for approval, prior to ordering.)

6

-

-

... More
Supply of office table (wooden top) of size 60" (width) x 36" (depth) x 30" (height) with three drawers on one side. Table support leg and three drawer with lock are to be made of metal. Table top Made of 18 mm pre-laminated board duly sealed with 2 mm PVC beading on all sides. Shall have single drawer unit on right side made of 0.5 mm thick prime quality CRCA MS sheet with overall size 355.5 (W) x 559 (D) x 433.5 (H) mm in three drawer option. ( The contractor should propse two or three makes, Meeting the spectifications, along with a detailed comparison and submit the same to the engineer incharge for approval, prior to ordering.)

4

-

-

... More
Supply of office use cane chair with arms: Seat and back are made from seasoned wood, caned (which blends of high and low density polyethylene) and finished with synthetic paint (Colour: Black). seat/back assembly Back size: 380 mm (W) x 400 mm (H) Seat size: 380 mm (W) x 425 mm (D) cane for seat/back, should have blends of high and low density polyethylene. cane strength The under structure assembly should be a cantilever type frame made of diameter 25.4 mm x2 mm thick MS ERW tube and powder coated (DFT 40-60 microns). The armrest tube should be of diameter 25.4 mm x2 mm thick MS ERW tube and powder coated (DFT 40-60 microns). ( The contractor should propse two or three makes, Meeting the spectifications, along with a detailed comparison and submit the same to the engineer incharge for approval, prior to ordering.)

4

-

-

... More
Supply of steel cupboard: overall size 915 mm (W) x 485 mm (D) x 1980 mm (H) including leg height of ~120 mm. CRCA steel sheet used for the body should be 0.9 mm thick as per IS-513 1994. Should have multi bend construction with interlocking design and full length over lapping doors and sides and should have three way bolting mechanism. The vertical two doors should have hinge mounted on frame Doors The doors have one handle and lever locking mechanism with 6- Six lever Mazak Zinc Plated Lock. All steel components should undergo eight tank anti rust treatment and oven Baked epoxy polyester powder coating with 50-60 micron dry film thickness. It should sustain Salt Spray test to withstand more than 1000 hours as per IS-101, Pencil scratch hardness more than 2H, Adhesion as per DIN 53152 Standards. Configuration It should have 4 adjustable shelves made of 0.8 mm thick CRCA steel sheet with stiffener. Steel sheet shall be oven baked epoxy polyester powder coated with 40-50 dry film thickness ( The contractor should propse two or three makes, Meeting the spectifications, along with a detailed comparison and submit the same to the engineer incharge for approval, prior to ordering.)

15

-

-

... More
Supply of Invertor welding machine, 7 KVA, 32A weighing around 10 Kg, suitable for 2.5 mm, 3.2 mm and 4 mm electrodes, make KEN or equivalent ( The contractor should propse two or three makes, Meeting the spectifications, along with a detailed comparison and submit the same to the engineer incharge for approval, prior to ordering.)

2

-

-

... More
Supply of 580R handheld drilling machine (connected with power cord) ( The contractor should propse two or three makes, Meeting the spectifications, along with a detailed comparison and submit the same to the engineer incharge for approval, prior to ordering.)

2

-

-

... More
Supply of metal cutter machine, 400V, 50 Hz, able to cut materials like iron, steel ( The contractor should propse two or three makes, Meeting the spectifications, along with a detailed comparison and submit the same to the engineer incharge for approval, prior to ordering.)

4

-

-

... More
Supply of power operated Stand Drill Drill depth: 50mm, semi-automatic, motor speed 1440 – 1600 RPM ( The contractor should propse two or three makes, Meeting the spectifications, along with a detailed comparison and submit the same to the engineer incharge for approval, prior to ordering.)

1

-

-

... More
Supply of handheld power operated metal grinder, disc dia 100mm, weighing less than 2 Kg ( The contractor should propse two or three makes, Meeting the spectifications, along with a detailed comparison and submit the same to the engineer incharge for approval, prior to ordering.)

4

-

-

... More
Supply of compressor for painting, capacity of 50 Litres, discharge pressure 8 to 12 bar, airtank capccity 500 L, AC three phase, less than or equal to 40 HP ( The contractor should propse two or three makes, Meeting the spectifications, along with a detailed comparison and submit the same to the engineer incharge for approval, prior to ordering.)

2

-

-

... More
Supply of 12 mm electric planer machine, 750W ( The contractor should propse two or three makes, Meeting the spectifications, along with a detailed comparison and submit the same to the engineer incharge for approval, prior to ordering.)

2

-

-

... More
Supply of portable hand planer, 10 mm, discharge pressure 8-12 bar The contractor should propse two or three makes, Meeting the spectifications, along with a detailed comparison and submit the same to the engineer incharge for approval, prior to ordering.)

2

-

-

... More
Supply of cut-off saw, 14” wheel dia, power input 2100 w, weighing less than 17 Kg ( The contractor should propse two or three makes, Meeting the spectifications, along with a detailed comparison and submit the same to the engineer incharge for approval, prior to ordering.)

1

-

-

... More
Supply of welding glass, black colour ( The contractor should propse two or three makes, Meeting the spectifications, along with a detailed comparison and submit the same to the engineer incharge for approval, prior to ordering.)

4

-

-

... More
Supply of helmet to be worne by the welder, fibre made, industrial use ( The contractor should propse two or three makes, Meeting the spectifications, along with a detailed comparison and submit the same to the engineer incharge for approval, prior to ordering.)

15

-

-

... More
Supply of all in one tool kit, package containing: Screwdriver Bits, Hexagon Socket Wrenchs, Precision Bits, Adaptors, Ratchet Hand Screwdrivers, Allen Keys, Masonry Drill Bits, S-Plugs, Screws, Flat-nose Pliers, Combination Pliers, 1 Tester, 1 Hammer, Cutter, Measuring Tape 3m, 1 Insulation Tape, 1 Torch, 1 Wrench, 1 Handsaw ( The contractor should propse two or three makes, Meeting the spectifications, along with a detailed comparison and submit the same to the engineer incharge for approval, prior to ordering.)

2

-

-

... More
Supply of Jig Saw, 1000 - 3100 Rpm ( The contractor should propse two or three makes, Meeting the spectifications, along with a detailed comparison and submit the same to the engineer incharge for approval, prior to ordering.)

1

-

-

... More
Supply of Plier 8"-70-482 sg ( The contractor should propse two or three makes, Meeting the spectifications, along with a detailed comparison and submit the same to the engineer incharge for approval, prior to ordering.)

2

-

-

... More
Supply of Mini Truck for the following specifications the rate including on road cost like Vehicle cost including body, Lift time road tax, Insurance for first year, Registration charges and all other taxes. Power - 75HP Engine speed - 3200RPM Payload - 1500kg Warranty - 3 Years / 1 Lakh Km whichever is later Cylinders - 4 Displacement - 2200CC Service Intervel - 10000 Km (Oil change ) Body Size - 8.4x5.6ft Transmission - 5 Speed(5F+1R) Gearbox - Synchromesh Clutch - single plate dry clutch Gradeability - 35% Max Speed - 80 Kmph Emission - BS6 Fuel Type - Diesel Fuel Tank - As per manufacturer Variants - Cabin with Flat bed load body GVW - As per manufacturer Seating Capacity - D+1 Axle Configuration - 4X2 Front Suspension - Rigid with leaf springs, With telescopic shock absorber / Semi elliptical leaf spring Rear Suspension - Rigid with leaf springs, With telescopic shock absorber / Semi elliptical leaf spring Anti Roll Bar - Front Ground Clearance - 195mm Overall Length - As per manuacturer Overall width - As per manuacturer Overall Length - As per manuacturer Steering - Power steering Service Brakes -Front : Hydraulic Disc , Rear : Hydraulic Drum colour - Client choice

1

-

-

... More
Supply, Installation, testing and commissioning of Biometric attendance system (BAS)through finger print with in built Time and attendance software in Drishya building, Chitranjali Studio comprising of the following :- 1.Network Switch D-Link & WIFI connectivity 2.Temper proof box for Machine 3.Power backup for 4Hrs 4. Attendance software with Dongle 5.All other necessary accessories etc., complete.

34

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.