Kerala State Film Development Corporation Limited Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kerala State Film Development Corporation Limited - KSFDC Tender

Works
Electronics Equipment
Electrical and Electronics
Eprocure
Opening Date6 Jan 2023
Closing Date4 Feb 2023
Tender Amount₹ 8,66,94,423 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

262.5

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

32.73

-

-

... More
5.33.1 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level

178

-

-

... More
5.33.2 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level

80.16

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

17660

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

16.8

-

-

... More
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

500

-

-

... More
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

288

-

-

... More
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

332

-

-

... More
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

100

-

-

... More
4.6.1 : Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), including the cost of required centering, shuttering complete.1:1.5:3 ( 1 cement : 1.5 coarse sand (Zone III): 3 graded stone aggregate 20 mm nominal size)

3.88

-

-

... More
4.12 : Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification .

37

-

-

... More
13.21 : Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.

47.88

-

-

... More
11.5 : 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufactures specification. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.

370

-

-

... More
16.68 : Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.

850

-

-

... More
16.47.1 : Painting runway/ taxi track /apron making with adequate nos of coats to give uniform finish with road marking paint of superior make as approved by the Engineer-in-Charge, i/c cleaning the surface of all dirt, scales, oil grease and other foreign material etc. and lining out complete.New work ( Two or more coats)

100

-

-

... More
16.62 : Providing and applying 2.5 mm thick road marking strips ( retro - reflective ) of specified shade / colour using hot thermoplastic material by fully / semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, T & P, cleaning the road surface of all dirt, seals, oil grease and foreign material etc. complete as per direction of Engineer - incharge and accordance with applicable specifications .

100

-

-

... More
16.59.1 : Manufacturing, supplying and fixing retro reflective sign boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols and borders etc. as per IRC: 67- 2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class-2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of M.S. angle iron of size 25x25x3 mm along with theft resistant measures, mounted and fixed with 2 Nos M.S. angles of size 35x35x5 mm to a vertical post made up to M.S. Tee section ISMT 50x50x6 mm welded with base plate of size 100x100x 5 mm at the bottom end and including making holes in pipes, angles flats, providing & fixing M.S. message plate of required size, steel work to be painted with two or more coats of synthetic enamel paint of required shade and of approved brand & manufacture over priming coat of zinc chromate yellow primer (vertical MS-Tee support to be painted in black and white colours). Backside of aluminium sheet to be painted with two or more coats of epoxy paint over and including appropriate priming coat including all leads and lifts etc. complete as per drawing , specification and direction of Engineer-in-Charge.Mandatory / Regulatory sign boards of 900 mm diametre with support length of 3750 mm

4

-

-

... More
50.6.1.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.

97

-

-

... More
50.6.3.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete

28

-

-

... More
13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)

350

-

-

... More
13.7.2 : 12 mm cement plaster finished with a floating coat of neat cement of mix:1:4 ( 1 cement : 4 fine sand)

1477

-

-

... More
11.41.2 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.

1433

-

-

... More
11.37 : Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.

251.48

-

-

... More
8.31 : Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineerin-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

579.81

-

-

... More
11.56.1 : Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

331

-

-

... More
11.55.1 : Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

50.4

-

-

... More
8.3.2 : Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work

75

-

-

... More
9.117.1 : Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1 mm), with wall thickness 2.0mm (±0.2 mm), corners of the door frame to be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 x 19 mm and 1 mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer's specification and direction of Engineer-in-chargeExtruded section profile size 48x40 mm

65

-

-

... More
9.118.1 : Providing and fixing to existing door frames24 mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x24 mm and 2 mm (± 0.2 mm) wall thickness,fixed to the shutter styles by means of plastic/galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge( For W.C. and bathroom door shutter).

21.84

-

-

... More
13.80 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

500

-

-

... More
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer

1200

-

-

... More
13.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work

1200

-

-

... More
13.46.1 : Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

1800

-

-

... More
13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work

100

-

-

... More
13.69.1 : Polishing on wood work with ready mixed wax polish of approved brand and manufacture:New work

100

-

-

... More
10.25.2 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works

9500

-

-

... More
21.18 : Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge ( Door handle, lock and stopper etc to be paid separately)

10.5

-

-

... More
21.1.1.3 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPolyester powder coated aluminium ( minimum thickness of polyester powder coating 50 micron )

600

-

-

... More
21.1.2.3 : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micorn)

140

-

-

... More
21.2.2 : Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides

15

-

-

... More
21.3.1 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness

10

-

-

... More
21.3.2 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness

20

-

-

... More
9.83 : Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.

8

-

-

... More
21.12.3 : Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0mm thick & 2100 mm long with S.S. screws etc. complete as per direction of Engineer -in-Charge.Polyester powder coated minimum thickness 50 micron aluminium tubular handle bar

7

-

-

... More
21.13 : Providing and fixing 100 mm brass locks ( best make of approved quality ) for aluminium doors including necessary cutting and making good etc. complete

6

-

-

... More
21.8.1 : Upto 5 mm depth and 5 mm width

40

-

-

... More
9.63.1 : Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete:250x10 mm

16

-

-

... More
9.63.4 : Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete:100x10 mm

16

-

-

... More
9.136 : Providing and fixing fire resistant door frame of section 143x57 mm having built in rebate made out of 16 SWG G.I. sheet ( zinc coating not less than 120 gm/ sqm) duly filled with vermuculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumuscent fire seal strip of size 10x4 mm (minimum) alround the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineer -in-charge (Dash fastener to be paid for separately ).

12

-

-

... More
9.137 : Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS : 3614 (Part - II), tested and certified as per laboratory approved by Engineer-in-Charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/m2) duly filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of approved make including applying a coat of approved fire resistant primer etc. all complete as per direction of Engineer -in-charge ( panneling to be paid for separately).

4.5

-

-

... More
10.16.1 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes

500

-

-

... More
10.15.1 : Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular /L-Type sections, made of 1.60 mm thick M.S. Sheet,joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 ( 1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

100

-

-

... More
9.1.1 : Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood

0.12

-

-

... More
9.5.1.2 : Providing and fixing panelled or panelled and glazed shutters for shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessery screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer - in-charge.Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) Second class teak wood 30 mm thick shutters

10.5

-

-

... More
15.3 : Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.

12.1

-

-

... More
15.7.1 : Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In mud mortar

53.24

-

-

... More
15.23.1 : Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm

941

-

-

... More
15.12.1 : Dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:Of area 3 sq. metres and below

32

-

-

... More
15.57 : Dismantling aluminium / Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 metres lead as directed by Engineer - in-Charge

70

-

-

... More
15.19 : Dismantling steel work manually / by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per directions of Engineer -in-Charge.

100

-

-

... More
Demolishing existing plumbing lines (PVC/UPVC) manually/ by mechanical means.including removing the clamp with screwe etc stacking of serviceable material and stacking of.unserviceable material within 50 metres lead as per direction of.Engineer-in-charge :up to 75 mm dia pipe

1000

-

-

... More
Demolishing existing plumbing lines (PVC/UPVC) manually/ by mechanical means.including removing the clamp with screwe etc stacking of serviceable material and stacking of.unserviceable material within 50 metres lead as per direction of.Engineer-in-charge :(above 75mm to 200mm ).

1000

-

-

... More
Dismantling/demolishing existing urinal,washbasin and water closet manually/ by mechanical means.including removing the screwes,stop cock and angle cock etc and stacking of serviceable material and stacking of.unserviceable material within 50 metres lead as per direction of.Engineer-in-charge :-urinal

20

-

-

... More
Dismantling/demolishing existing urinal,washbasin and water closet manually/ by mechanical means.including removing the screwes,stop cock and angle cock etc and stacking of serviceable material and stacking of.unserviceable material within 50 metres lead as per direction of.Engineer-in-charge :-for washbasin

15

-

-

... More
Dismantling/demolishing existing urinal,washbasin and water closet manually/ by mechanical means.including removing the screwes,stop cock and angle cock etc and stacking of serviceable material and stacking of.unserviceable material within 50 metres lead as per direction of.Engineer-in-charge :-for water closet

25

-

-

... More
Dismantling/demolishing below listed existing items by manually/ by mechanical means.including removing the screwes,and stacking of serviceable material and stacking of.unserviceable material within 50 metres lead as per direction of.Engineer-in-charge :-Hand rail (full unit)-newel ,baluster and railing

12

-

-

... More
screen-1( considered by single job)-620 sqm floor area,720 sqm ceiling area and 980 sqm wall area-Dismantling/demolishing the fabric and plywood base from the existing fabric wall paneling ,Dismantling/demolishing the existing false ceiling ,removing the wooden paneling , clear all interior works and MEP works . stacking of serviceable material and stacking of.unserviceable material as per direction of.Engineer-in-charge :( including scaffolding for height work)take proper safety measures while on height work .All the demolished materials (unserviceable)/building rubbish should be disposed by the contractors scope, as per the direction of client :( including loading ,unloading and transportation .)

1

-

-

... More
screen-2( considered by single job)-450 sqm floor area,550 sqm ceiling area and 840 sqm wall area -Dismantling/demolishing the fabric and plywood base from the existing fabric wall paneling ,Dismantling/demolishing the existing false ceiling ,removing the wooden paneling , clear all interior works and MEP works. stacking of serviceable material and stacking of.unserviceable material as per direction of.Engineer-in-charge :( including scaffolding for height work)-take proper safety measures while on height work -All the demolished materials (unserviceable)/building rubbish should be disposed by the contractors scope, as per the direction of client :( including loading ,unloading and transportation .)

1

-

-

... More
sheet piling over areas including strutting, shoring and packing cavities (wherever required) etc. complete. (Measurements to be taken of the face area of sheet pile):- up to 1.5 m

55

-

-

... More
Sheet piling by mechanical over areas including strutting, shoring and packing cavities (wherever required) etc. complete. (Measurements to be taken of the face area ) : -1.5 to 3 m .

45

-

-

... More
Sheet piling by mechanical over areas including strutting, shoring and packing cavities (wherever required) etc. complete. (Measurements to be taken of the face area ) : -3 to 4.5 m.

45

-

-

... More
Providing RCC slab cutting(3 Floors) with diamond blade/diamond wire by mechanical means.including stacking of serviceable material and disposal of unserviceable material as per direction of Engineer-in-charge :(including scaffolding for height work) All the demolished materials (unserviceable)/building rubbish should be disposed by the contractors scope, as per the direction of client :( including loading ,unloading and transportation .).

3.5

-

-

... More
Supplying and fixing C.I cover with frame for tanks etc,600x600 mm clear C.I cover ( heavy duty).

12

-

-

... More
Providing and laying lawn grass(zoysia)over the loose soil bed(300mm red earth) and including the labour of loose soil bed and all other charges , excluding the cost of red earth .

15

-

-

... More
Providing and fixing wall or column panelling(12mm thick marine ply) with 1mm laminate finish ,suitable fixing on the wall .including mateial labour ,all other material for fixing etc completed -all complete as per direction of Engineer-in-charge

580

-

-

... More
Providing and laying 2D textures wall paper on the wall including material labour and all other charges Marshalls/or eqivalent brand-all complete as per direction of Engineer-in-charge .

450

-

-

... More
Supplying and providing compact laminate cubical toilet of clean and lean look and door width 600mm, bottom gap 150mm with 12mm thick merino/equivalent make HPL compact laminate panelsof desired colors for partition , dividers, doors, end/mid pilasters. aluminum anodinized toprail for toilet spaces with merino/equivalent make including hardware and accessories made with PA-6 grade nylon viz. door knob, thumb turn lock set with occupancy indicator.Accesories viz. privacy thumb turn indicator,door knob,coat hook, gravity door hinge,adjustable leg,aluminium door stopper,rubber lining for door stopper,fasteners etc including labour charges,cost of materials,all lead and lifts and all incidental charges.

80

-

-

... More
Applying one coat of wood primer primer of approved brand and manufacture on wall surface : .

100

-

-

... More
Applying one coat of metal primer(for steel work) of approved brand and manufacture on wall surface : .

100

-

-

... More
Leveling, curving , aligning and re-erection of existing big screen frame .including cutting ,welding, scoffolding and all other charges .

820

-

-

... More
Providing and fixing 12 mm thick frameless toughened glass partition wall of approved brand and manufacture, including providing and fixing top & bottom powder coated aluminium U frame, fixing arrangement and making necessary holes etc. all complete as per direction of Engineer incharge.

180

-

-

... More
Providing and fixing 12 mm thick frameless Curved toughened glass partition wall of approved brand and manufacture, including providing and fixing top & bottom powder coated aluminium U frame, fixing arrangement and making necessary holes etc. all complete as per direction of Engineer incharge.

30

-

-

... More
Providing and fixing 12 mm thick frameless toughened glass automatic sliding door of approved brand and manufacture, with required door fittings, including automation and all complete as per direction of Engineer-in-charge .

10

-

-

... More
Providing and fixing 5mm zero reflection glass for opening of projectro room with EPDM rubber / neoprene gasket etc.Including powder coated aluminium U frame complete as per the architectural drawings and the directions of engineer -in-charge .

3

-

-

... More
12.50 : Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.

20

-

-

... More
9.159 : Providing and fixing 25mm thick pre-laminated medium density fibre board exterior grade (Grade-I) IS:14587:1998 marked one side decorative and other side balancing lamination for cupboard shutters edges to be sealed with PVC edge bending tape 2.00 mm thick of approved brand including ISI marked nickeled plated bright finishing M.S. piano hinge IS: 3818 marked with necessary screwed complete.

50

-

-

... More
Supplying and fixing information signages using 3M Vinyl sticker ,fixing it in position as per drawings, specification and direction of the engineer-in charge, cost and conveyance of all materials and labour charges, scaffolding charges etc complete.Information signages".

3

-

-

... More
Supplying and fixing LED signages Using PT class Acryilic sheet,LED module of approved ma, Poweron SMPSk etc.The rate includes the cost of rounding off the corners,fixing and erecting the same in position all complete as per drawings, specification and direction of the engineer-in- charge. Rectangular area of the sheet only shall be measured for payment cost and conveyance of all materilas and labour charges, scaffolding charges etc complete.For Building & Front Arch".

3

-

-

... More
od150211/2022_2023 : Providing and fixing PVC water stopper ( 30 mm x 8mm thick ) with all accessories

60

-

-

... More
50.2.3.1 : Pumping or Bailing out water and removing slush etc by using pump set including cost of labour, oil hire charges of pumpset, etc complete

150

-

-

... More
50.2.25.1 : Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge

360

-

-

... More
22.6 : Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tilling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured)

20

-

-

... More
12.45.1 : Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum plain board conforming to IS : 2095-Part 1

1400

-

-

... More
26.22.1 : Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity 0.043 W/m K as per ASTM 518:1991,in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main- T runners of size 24x38 mm of length 3000 mm, cross - T of size 24x32 mm of length 1200 mm and secondary intermediate cross-T of size 24x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge.With 15 mm thick tegular edged light weight calcium silicate false ceiling tiles.

40

-

-

... More
8.32 : Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: (a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. (b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. (c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places.

3

-

-

... More
10.16.2 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished seamless type tubes

1000

-

-

... More
Sanitary fixtures & Bath fittings Part A

-

-

-

... More
17.10.2.1 : Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink without drain board610x510 mm bowl depth 200 mm

2

-

-

... More
17.28.1.1 : Providing and fixing P.V.C. waste pipe for sink or wash basin including PVC. waste fittings complete.Semi rigid pipe32 mm dia

2

-

-

... More
17.31 : Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

8

-

-

... More
50.17.1.3 : Supplying and fixing CP Towel rod 60cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.

2

-

-

... More
17.4.1 : Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required:One urinal basin with 5 litre white P.V.C. automatic flushing cistern

33

-

-

... More
Sanitary fixtures & Bath fittings Part B

-

-

-

... More
Providing and fixing Disabled Toilet, Complete Set, including White Floor Mounted Water Closet, Plastic Cistern , Lid, Antimicrobial Seat Cover etc, Faucet/Tap with spactula lever and with 1no of Hinged Arm, 760mm. Long, 2nos of Grab Rail, each of 600mm. long, and with all necessary accessories and fixed with Brackets Expansion/Rawl sleeves, stainless steel/ brass bolts/screws, nuts, washers etc, including cutting and making good the walls and floors wherever required. including all as per manufacture's and to the approval of Engineer-in-charge.

1

-

-

... More
Providing and fixing CP brass bib cock of approved quality having low flow fixture unit confirming to green building norms throught selection of low flow fix by 50% below the griha base rate confirming to IS standards.

20

-

-

... More
Providing and fixing of 15 mm C.P. with Hand Shower (Health Faucet) with 8mm Dia, 1.2 Meter Long Flexible Tube & Wall Hook flow restrictor confirming to green building norms throught selection of low.flow fix by 50% below the griha base rate including all fittings and brackets of approved quality-".

36

-

-

... More
Providing & fixing, testing and commissioning of approved make & coloured urinal division plate of size 90 x320x720mm and fixed to wall by using CP brass screws etc. complete as per specifications.

32

-

-

... More
Providing and fixing of 15 mm C.P. brass sink cock wall mounted with 188mm long swivel spout and wall flange having confirming to green building norms throught selection of low flow fix by 50% below the griha base rate.

2

-

-

... More
Providing and fixing of 15 mm C.P. Brass pressomatic Pillar Cock with Auto Closing System confirming to green building norms throught selection of low flow fix by 50% below the griha base rate as per the IS Standards.".

12

-

-

... More
Providing and fixing wash basin with C.I. brackets, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 460x350mm.

12

-

-

... More
Supply,Installation,testing and commissioning of Two piece wall hung extended EWCs with seat cover and cistern with twin flush fittings (with 'p' trap of IS specification make and approved by the consultant) , MS / CI chair brackets, fischer bolts with CP bolts / nuts andflanges confirming to green building norms throught selection of low flow fix by 50% below the griha base rate, solid plastic seat and lid with heavy duty CP hinges and rubber buffers and flap etc. The work shall include cutting making of walls and floors etc. Notes: Necessary consumables like brass screws, CP extension nipple of approved make, dia and length, wooden plugs, white cement, sealants etc., required if any, shall be arranged by the contractor. .

36

-

-

... More
Providing and fixing CP over head shower approved quality having low flow fixture unit.

2

-

-

... More
Supplying and fixing Towel hook including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.

32

-

-

... More
Domestic Water supply lines - Water supply (wall/floor Concealed)

-

-

-

... More
18.8.2 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.20 mm nominal outer dia pipes

450

-

-

... More
Water supply (Ceiling suspended )

-

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Ceiling suspended work with necessary support and clamps at 1mtr interval.20 mm nominal outer dia pipes.

30

-

-

... More
25 mm nominal outer dia pipes.

35

-

-

... More
32 mm nominal outer dia pipes.

35

-

-

... More
40 mm nominal outer dia pipes.

30

-

-

... More
Water supply Lines (through shaft)

-

-

-

... More
Providing ,fixing,testing and commissioning of uPVC SCH-40 pipes confirming to ASTM D- 1785, including all fitting uPVC SCH-80 conforming to ASTM D 2467, like tees, elbows ,bends, unions, coupling, reducer tees, collars etc.The work shall include cutting jointing with solvent cement pressure testing the joints/pipeline for 10kg/sq.cm pressure. making holes, including chasing in solid block mansory walls to required width and depth, making bores in walls, foundation and RCC slabs, making good the walls and bores as applicable clearing the debris grouting of concealed pipes,MS hooks for fixing pipes and making good the walls and floors.32mm dia.

35

-

-

... More
50 mm pipes.

50

-

-

... More
40 mm pipes.

50

-

-

... More
Water supply Lines (through Terrace)

-

-

-

... More
Providing ,fixing,testing and commissioning of uPVC SCH-40 pipes confirming to ASTM D- 1785, including all fitting uPVC SCH-80 conforming to ASTM D 2467, like tees, elbows ,bends, unions, coupling, reducer tees, collars etc.The work shall include cutting jointing with solvent cement pressure testing the joints/pipeline for 10kg/sq.cm pressure. making holes, including chasing in solid block mansory walls to required width and depth, making bores in walls, foundation and RCC slabs, making good the walls and bores as applicable clearing the debris grouting of concealed pipes,MS hooks for fixing pipes and making good the walls and floors.20 mm pipes.

10

-

-

... More
40 mm pipes.

30

-

-

... More
32 mm pipes.

30

-

-

... More
65 mm pipes.

15

-

-

... More
50 mm pipes.

70

-

-

... More
Providing ,fixing,testing and commissioning of uPVC SCH-80 pipes confirming to ASTM D- 1785, including all fitting uPVC SCH-80 conforming to ASTM D 2467, like tees, elbows ,bends, unions, coupling, reducer tees, collars etc.The work shall include cutting jointing with solvent cement pressure testing the joints/pipeline for 12kg/sq.cm pressure. making holes, including exposed in solid block mansory walls to required width and depth, making bores in walls, in ground by excavation and refilling wherever necessary,foundation and RCC slabs, making good the walls and bores as applicable clearing the debris grouting of concealed pipes,MS hooks for fixing pipes and making good the walls and floors (Pumping line).40mm dia

50

-

-

... More
Soil/Waste water internal (wall/floor Concealed/Ceiling suspended ) Part A

-

-

-

... More
50.18.8.6.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 6 kgf/cm2

40

-

-

... More
50.18.8.7.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work including cutting chases and making good the wall etc. 63 mm pipe 6 Kgf/cm2

60

-

-

... More
50.18.8.8.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 75 mm pipe 6 Kgf/cm2

100

-

-

... More
50.18.8.9.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2

80

-

-

... More
50.18.9.9.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2

90

-

-

... More
50.18.9.10.1 : Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2

130

-

-

... More
50.18.9.8.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75 mm dia 6 Kgf/ cm2

10

-

-

... More
50.18.9.18.2 : Providing and fixing PVC pipes including fixing the pipe with clamps/Clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 4 Kfg/cm2 - External work - Exposed on wall

90

-

-

... More
Soil/Waste water internal (wall/floor Concealed/Ceiling suspended ) Part B

-

-

-

... More
Supply and fixing of CP grating with rim including setting in floor with white cement mortar and making good the floor.

42

-

-

... More
Supply,fixing,testing comissioning of multi inlet PVC floor trap with boss coupler suitable for ceiling suspended/sunken system with minimum 50mm water seal moulded ,with or with out vent arm jointing with rubber ring /solvent cement followed by application leakproof adhesive including making good the floors.

42

-

-

... More
Providing and fixing PVC pipes, fittings, including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall.

110

-

-

... More
Providing and fixing PVC pipes, fittings, including fixing the pipe with clamps/clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 - External work- Exposed on wall.

45

-

-

... More
Rain water pipes (external in shafts/ slabs etc)Part A

-

-

-

... More
50.18.9.9.2 : Providing and fixing PVC pipes includes joints of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in CHarge. 110 mm dia 4 Kg/cm2

90

-

-

... More
50.18.9.19.2 : Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 m dia 4 Kgf/cm2 - External work - Exposed on wall

60

-

-

... More
Rain water pipes (external in shafts/ slabs etc) Part B

-

-

-

... More
Supply ,fixing ,testing and comissioning of PVC rain water head /khurra with grating, puddle flange to fix head in RCC slab specially fabricated from minimum 4mm thick PVC sheet including removable heavy duty PVC grating as per approved design .The quoted rate shall include necessary grouting the base of Khurras with aproved sealent complete.

11

-

-

... More
Supplying and fixing of approved make at site GI Slotted Rail Brackets,hangers,c clamp supports with necessary drilling holes to suit the insirtion of pipe clamps, deburring etc.,as per detailed drawing for supporting soil, waste & rain water pipes & water supply pipes in shafts and ceiling with suitable GI clamps,bolts,anchor bolts nuts & washers fixed on shaft walls/outer walls etc with 6mm / 8mm dia full threaded GI rod.The quoted rate shall include with the cost of brackets galvanizing with zinc alloy of 1.6mm thick confirmed to IS 1239 etc.,complete as directed by the employer.

120

-

-

... More
Providing and fixing PVC pipes includes joints of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. .160 m dia 4 Kgf/cm2.

125

-

-

... More
Butterfly valve

-

-

-

... More
Supply ,fixing,testing and comissioning of the Valves of cast iron lever operated slim seal type valves of CI body and spheroidal iron disc with nitrile rubber seal ,tested 10KG sqmm confirming BS 5155 /MF6 standards and including a set of GI flanges as per BS 10 table including bolts and nuts,and Neoprane rubber gaskets etc.Butterfly Valve 65mm.

2

-

-

... More
Butterfly Valve 50mm.

3

-

-

... More
Ball Valves

-

-

-

... More
Supply ,Fixing ,testing andComissioning of Ball valves of brass body nickel plated with brass ball ,lever operated and tested to 20KG/sq.cm.20 mm dia.

40

-

-

... More
Ball Valve 25mm.

2

-

-

... More
Ball Valve 40mm.

8

-

-

... More
Ball Valve 32mm.

3

-

-

... More
Y strainer

-

-

-

... More
Supply ,fixing,testing and comissioning of the cast iron Y type strainer body with suitable flanged ,tested 15KG sqmm confirming IS 210 Gr Fg 200 with screen of SS304 standards and including a set of GI flanges as per BS 10 table including bolts and nuts,and Neoprane rubber gaskets etc.65 mm dia..

2

-

-

... More
Air Release Valve

-

-

-

... More
Supply, installation, testing and commissioning of 20mm. Air Release Valve gunmetal, conforming to IS 903:1993, having rubber ball and with 20mm. BSP threaded male inlet, including necessary accessories and connections.20 mm air release valve.

7

-

-

... More
Pits and Manhole

-

-

-

... More
18.37.1 : Constructing masonry chamber 60x45x50 cm inside, in brick work in cement mortar 1:4 ( 1 cement : 4 coarse sand) for water meter complete with C.I double flap surface box 400x200x200 mm ( inside ) with locking arrangement and RCC top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 grades stone aggregate 20 nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 ( 1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design:With common burnt clay F.P.S. ( non modular ) bricks of class designation 7.5

2

-

-

... More
19.4.2.1 : 150x100 mm size P typeWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5

7

-

-

... More
19.33 : Constructing soak pit 1.20x1.20 m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design.

3

-

-

... More
19.31.3.1 : Extra for depth beyond 45 cm of brick masonry chamber:For 600x850xmm sizeWith common burnt clay F.P.S. ( non modular) bricks of class designation 7.5

23

-

-

... More
PUMPS

-

-

-

... More
Providing & Fixing, testing and commission, of submersible Type Water Transfer Pump, for pumping water from basement collection pit to external drain with including level switches, control wires ,startor etc.The price shall inclusive of all connected electrical work. Three phase 0.75KW/1 HP, Sewage submersible pump with , 40 mm delivery suitable for 6 to 12 mtr head and 336 to 145 LPS discharge respectively. Partcile handling size 20mm , 1 working +1 standby, three phase, 415V, AC supply Pumping from basement collection pit.

1

-

-

... More
Providing & Fixing, testing and commission, of open well submersible Type Water Transfer Pump, for pumping water from Underground water tank to overhead domestic water tank with including level switches, control wires ,startor etc.The price shall inclusive of all connected electrical work. 1.1KW/1.5 HP, submersible type clear water pump with,50 mm suction and 40 mm delivery suitable for 16 to 30 mtr head and 3.4 to 1 LPS discharge respectively. , 1 working +1 standby, three phase, 415V, AC supply Pumping from sump to OH.

1

-

-

... More
MISCELLENAOUS

-

-

-

... More
Supply and fixing of plastic ball float valve with gun metal lever of IS specification make and approved by the client / consultant for muncipal water inlet pipe to UG sump.

1

-

-

... More
Supplying & Fixing at site in position Fabricated u PVC Astm Sch 80 Puddle flanges in the underground and overhead water tanks as per the drawings and the requirement of the Project Manager.100 mm dia.

1

-

-

... More
40 mm dia.

1

-

-

... More
65 mm dia.

2

-

-

... More
Providing & fixing 130 mm size Floor clean outs stainles steel as per the directions of engineer in charge with all the necessary fittings.

12

-

-

... More
Providing of 4 pair 1.5 sq mm cable as control cable of liquid water level controller tincluding ISI Heavy duty 20mm conduit.

100

-

-

... More
Providing & fixing of plastic type P-Trap with all the necessary acessories required for the installation.63mm

9

-

-

... More
Supply,Installation, testing and commissioning of smart water meter confirming to IS 4064(1) of multijet class B magnetic type 100mm meter battery powered with neccesary fittings such as threaded pieces, unions, check nuts complete as required for following dia:.25mm dia

1

-

-

... More
Non return valve

-

-

-

... More
18.19.3.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):40 mm nominal boreHorizontal

2

-

-

... More
Fire Pump Accessories

-

-

-

... More
MAIN PUMP.Supply,Installation, Testing and Commissioning of Electrical Driven Main Pump suitable for automatic operations and consisting of the following:-a) End suction type fire pump capable for delivery of 2850 LPM,90 M head of 2900 RPM with Bronze impeller. b) Squirrel cage, Totally Enclosed Fan Cooled induction Motor suitable for 415 V, 3 Phase 50 Hz AC supply, of suitable capacity for the above pump, rated 100 HP with class ‘F’ insulation. c) Common bedplate of requisite strength fabricated out of MS channel type). The quoted rate shall includes control wiring ,cable trays with all accessories required for connections between Pump panel and pump, Providing and fixing of coupling, coupling guard, RCC foundation (as recommended by manufacturer) and foundation bolts, antivibration pad.

2

-

-

... More
Supply,Installation,Testing and Commissioning of Diesel Engine Driven Fire Pump of approved make suitable for automatic/manual operations consisting of the following, End suction type fire pump capable for delivery of of 2850 LPM against a total head of 90Mtrs with rated 105 hp to ensure a minimum pressure of 3.50Kg per Sq.cm at the farthest outlet, complete having tail pieces for proper connetion to suction and delivery line, having a name plate indicating suction, delivery, head, discharge, stages , R.P.M, and direction of rotation.(as per specifications) ii) Diesel engine suitable for the above pump complete with stanadard accessories including 100 ltr diesel tank and suitable water cooling system. iii)Suitable mechanical seal with mounting arrangement iv)Tyre type Coupling and coupling guard for direct coupling of engine & pump. .

1

-

-

... More
Fabrication, supply, erection, testing and commissioning of Automatic motor control panel of cubicle type, dust and vermin proof, floor/wall mounted, front operated power control make MV panel board made out of 14 SWG thick CRCA sheet fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel and including inbuilt fire spot panel protection unit of 4kg capacity, with heat detection tube of sufficient length which runs across the panel covering all devices etc including all components as required. All opening parts of the panel shall be sealable. Panel shall be fabricated with necessary provision for Class B + Class C/ Class 1 + Class 2 Surge arrestor device.Including providing surge arrestor and necessary MCCB switch for its protection and Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant. .This panel should include Pluggable type surge arrester Class B & Class C/ Class 1 & Class 2 as per IEC 61643 (IP 20) with potential free contact, with IP 66 completely assembled enclosure & provision for inbuilt common remote indication for defective arresters ,3 nos of encapsulated spark gap & 3 nos of single large block of MOV with series thermal fuse and cooling gel to connect between Line and Neutral and one number arrester encapsulated spark gap type to connect between Neutral and Earth of following ratings including base element & pluggable arresters. Nominal voltage -230V 50Hz, Impulse current-150 KA (10/350µ sec) & 60KA (8/20µ sec) for Line to Neutral & 125 KA(10/350µ sec) for Neutral to Protective Earth, voltage protection level <1.3 KV ( L to N) & <1.3 KV ( N to E). Operating temp -40º to +85ºC. Response time <100 nano sec.Incomer:400A TPN Isolator .400A 415V, 16kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement.Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, kWh, KW, frequency, KVA, kVAr, PF, kVArh, Runhours, On hours, Interupts, RPM, % Unbalance (V,A), Phase angle, THD etc. - 1 No (for incomer).RYB phase indicating LED lamps with control fuses and switches - 1 set.CTs- ratio 400/5A 15VA CL-1 - 1 no. .Outgoing.250A, TP Isolator -2 NOS.63A, TP Isolator -2NOS.250A Star delta starter.-2NOS.63A Star delta starter.-2NOS.

1

-

-

... More
DIESEL ENGINE STARTER PANEL.Supply,storing,erection,testing and commissioning of wall mounted 24 volts control panel to start the fire pump engine automatically as per the following sequence of operation and the auxiliary arrangements.a) Engine to start automatically incase of low water pressure secured by the pressure switch with necessary timers,relays etc.b) Manual stopping.c) Audio visual alarm for :.i) Low fuel oil level.ii) Engine over speed.iii) High water temperature.iv) Low type oil pressure.v) Engine fails to start.d)A battery charger with trickle/Boost arrangements with secondary side tapping at 28,30,32 and 34volts equipped with silicon diodes to charge the starting battery of the diesel engine.".

1

-

-

... More
Supply, erection, commissioning of additional length of exhaust pipes for diesel engine exhaust pipe with insulation and aluminium clading, along with long radius bend from residential silencer with necessary clamps, fixtures, civil works and painted with heat resistant, rust proof, bituminous paint of approved colors to a maximum of 10 m in stages of following sizes including suitable rain cap for top to avoid rain water entry. The distance between exhaust pipe and rain cap should be higher than diameter of pipe. It is also recommended that horizontal run of exhaust piping should slope downwards away from engine to the condensate trap. Silencer should be installed with drain plug at bottom. Fixing shall be done with proper clamps, expansion bolts, and all other acessories as instructed by the Engineer and the rate inclusive of all minor civil works required for istallation.

20

-

-

... More
Supply, installation, testing and commissioning of Electric Driven Jockey pump for automatic pressurization of wet riser system in cases of miner leakages consisting of the following: a) End suction type fire pump Bronze impeller, running at 2900 RPM capable of delivering 180LPM against a head of 90 Mtrs b) Squirrel cage TEFC induction motor suitable for 415V, 3 phase, 50Hz AC ( 12.5HP) .The quoted rate shall includes control wiring ,cable trays with all accessories required for connections between Pump panel and pump, Providing and fixing of coupling, coupling guard, RCC foundation (as recommended by manufacturer) and foundation bolts, antivibration pad.Foundation to be done under scope of contractor.

2

-

-

... More
HYDRANT PIPING SYSTEM

-

-

-

... More
Supply, Installation,Testing and Commissioning of slim seal type butterfly valves PN 1.6, OS & Y type with out lugs, lever operated type confirming to IS 5312 with necessary fittings. BUTTERFLY VALVE -150mm dia.

3

-

-

... More
Supply, Installation,Testing and Commissioning of slim seal type butterfly valves PN 1.6, OS & Y type with out lugs, lever operated type confirming to IS 5312 with necessary fittings. BUTTERFLY VALVE -100mm dia.

3

-

-

... More
Supply,Installation, Testing and Commissioning of double flanged horizontal type Non-Return Valve as per IS 5312 of following sizes having CI body and GM moving parts, with nuts bolts, gaskets etc & tested 21 kg/cm2 100 mm dia.

3

-

-

... More
Under Ground Piping: Supplying, erection, testing and commissioning of G.I 'C' class pipes confirming to IS :1239 part I with malleable specials confirming to IS : 1239 part - II, such as elbows, reducers, flanges etc. Including cutting, welding, fixing in/on walls, ceiling by using suitable supports, and wrapping with polymer corrossion protection tape comfirming to IS 10221 with proper overlapping, trimming etc complete. etc. complete(The Rate for excavation shall be extra as applicable) .150 mm Dia.

113

-

-

... More
Above Ground Piping: Supplying, erection, testing and commissioning of G.I 'C' class pipes confirming to IS :1239 part I with malleable specials confirming to IS : 1239 part - II, such as elbows, reducers, flanges etc. Including cutting, welding, fixing in/on walls, ceiling by using suitable supports, The pipe shall be painted with one coat of primer and two coats of synthetic enamel paint of approved colour shade. (Core cutting in walls/ beams/ columns for laying pipes shall be provided by client, if necessary) .150 mm Dia.

5

-

-

... More
200 mm dia.

10

-

-

... More
100 mm Dia.

320

-

-

... More
Providing and fixing 150 mm CI `Y' strainer suitable for operating pressure of 16 Kg / sqcm with SS 304 perforated sheet basket including rubber gasket, flanges, nuts, bolts and washers, complete as required.

2

-

-

... More
SERVICE FOR WEAR AND TEAR OF EXISTING ITEMS.Servicing of G.I 'C' class Hydrant riser pipe Including cutting, welding, fixing in/on walls, ceiling by using suitable supports and The painting with one coat of primer and two coats of synthetic enamel paint of approved cocour shade.

16

-

-

... More
Supplying, Installation, testing and commissioning of C.I. Non- Return Valve Slim seal type with required flanges, nuts & bolts, gasket etc. complete.150MM

1

-

-

... More
FIRE HYDRANT ACCESSORIES

-

-

-

... More
Supplying, Installation, testing and commissioning of instantaneous pattern Gunmetal Single Headed Hydrant Valve of 63mm Dia, oblique type, instantaneous hose coupling adaptor as per IS: 5290 complete with PVC blank cap etc. .

8

-

-

... More
Supply and placed in position of Aluminium Branch Pipe, 63mm female instantaneous inlet, male threaded outlet, complete with hexagonal base nozzle as per IS:903.

8

-

-

... More
Supply and placed in position of Controlled Percolated Hose conforming to IS: 636, 63mm dia 15 Mtrs length with Aluminium heavy duty 63 mm pair of male and female coupling etc.

16

-

-

... More
Supplying, Installation, testing and commissioning of Hydraulic Hose Reel drum completed with swinging type drum with 19mm dia Rubber braided hose of 30M. Length and shutt off nozzle, with necessay fittings etc. complete.

8

-

-

... More
Supply and Fixing of weather proof Hose cabinet suitable size " 30 x24 x10 inch having made of 16 gauge MS Sheet with common keylock arrangements, suitable to accommodate two lengths of 15mtr hoses,one headed hydrant valves , hose reel and one no branch pipe with nozzle. The cabinet shall be painted to scarlet red colour out side and off-white inside. for internal and external.

8

-

-

... More
Supply installation,commisioning of 50mm forged ball valves.

5

-

-

... More
Supply installation,commisioning of 25mm forged ball valves.

2

-

-

... More
Supplying, Installation, testing and commissioning of single acting Air Release Valve with screwed inlet 25 mm dia etc.

2

-

-

... More
Supply, installation, testing and commissioning of Fire Brigade Inlet connection with 3 nos of 63 mm dia. built - in Gun metal Non- return valves instantaneous coupling type in a 16 swg Ms cabinet size 1000 x 300 x 400 .

1

-

-

... More
Supplying, Installation, testing and commissioning of Pressure Gauge with required range/ capacity.

1

-

-

... More
Supplying, Installation, testing and commissioning of Pressure Switch for automatic operation.

3

-

-

... More
Supply,Installation, Testing and Commissioning of Air cushion tank (air-vessel) 200 mm dia. x 1.5 M high with dished top, made of minimum 6 mm thick M.S. pipe/plate complete with 25 mm dia. Brass Air Valve (Ball valve, pressure gauge type), 25 mm dia. Stop with brass stop cock, nipple, tees, elbow, pipe, drain valve and all accessories as required incl. fixing brackets.

1

-

-

... More
SERVICE FOR WEAR AND TEAR OF EXISTING ITEMS.Servicing and reusing of already existing items like hydrant valves,hose reel drums,hoses,Branch pipes and hose cabinets.

5

-

-

... More
Automatic Sprinkler System

-

-

-

... More
Above Ground Piping: Supplying, erection, testing and commissioning of M.S 'C'class pipes confirming to IS :1239 part I with malleable specials confirming to IS : 1239 part - II, such as elbows, reducers, flanges etc. Including cutting, welding, fixing in/on walls, ceiling by using suitable supports, The pipe shall be painted with one coat of primer and two coats of synthetic enamel paint of approved colour shade. (Core cutting in walls/ beams/ columns for laying pipes shall be provided by client, if necessary) .100 mm Dia.

130

-

-

... More
65 mm Dia.

93

-

-

... More
80 mm Dia.

130

-

-

... More
25MM

770

-

-

... More
32MM

62

-

-

... More
40MM

184

-

-

... More
50 mm Dia.

170

-

-

... More
BUTTER FLY VALVES FOR SPRINKLER PIPING.Supplying, Installation, testing and commissioning CI Butterfly valve slim seal standard lever operated type with required flanges, nuts, bolts etc. complete.100MM

4

-

-

... More
80 MM.

1

-

-

... More
CONVENTIONAL FIRE ALARM SYSTEM

-

-

-

... More
Supply, Installation, Testing and Commissioning of Microprcessor based fire alarm and indicating panel of 2 Zones conventional type complete with charger, rectifier, alarm display facilities, feather touch key pads etc and with 2x12 V SMF batteries and made functional.

1

-

-

... More
Supply,Installation,Testing and Commissioning of photo electric type smoke detectors with base unit,CE approved.

115

-

-

... More
Supply,Installation,Testing and Commissioning of heat detector with base unit,CE approved.

13

-

-

... More
Supply,Installation,Testing and Commissioning of 2C X 1.5 SQMM Multistranded flexible copper conductor cable with ISI MARK.

1420

-

-

... More
Supply laying of 20mm dia Pvc conduit pipe with accesorries and ISI MARK.

1100

-

-

... More
Supply, Installation,Testing and Commissioning of analog Manual pull station break glass type at indicated locations with necessary termination as per acceptable specifications and full ready for operation.

10

-

-

... More
Supply,Installation,Testing and Commissioning of sounder with strobe units,CE approved.

10

-

-

... More
PA SYSTEM / TALK BACK SYSTEM

-

-

-

... More
Supply,installation,testing & commisioning of automatic control console of 3 zones microprocess based complete with floor to floor announcing and talk back facilities with the following features and made functional: (a) Feather type keypad s to select the zones. (b) Moulded plastic attractive enclosure. (c)Backlight Liquid Crystal Display (LCD) (d) Userfriendly interactive display. (e) Announcement selector-PTT Switch . (f) Listen selector switch. (g) All Call switch to select all zones simultaneously for announcement (h)Zones Call Display On the LCD With Audio Alarm. Panel to be installed in the Fire Control Room. .

1

-

-

... More
Supply , installation , testing and commisioning of Public Address speaker with talk back facility 6/12 Watts with LMT and call switch , made out of powder coated CRCA sheet , wall mounting type and to be installed at a height of not less than 150 CM from the finished floor levels, suitable for concealed mounting. .

10

-

-

... More
Supply,Installation,Testing and Commissioning of 1Cx1sq.mm mutistranded flexible copper conductor wire with ISI mark.

570

-

-

... More
Supply and laying of 20MM Dia PVC conduit pipes with ISI mark and with all the accessories.

550

-

-

... More
SIGNAGES

-

-

-

... More
Fire Exit, Exit, Fire Lift & Fire Duct signage at each stair on every floor, indicating the direction of fire exit, lettering size shall be 7.5 cm with contrasting color from back ground as per standards. Size shall be 15cm x 60cm. .

24

-

-

... More
Supply and installation of in position the signages "FIREORDER" it should contain the following matter on 3mm thick "Opaque" PVC foam board of computerized cut, PVC Non-reflective self adhesive vinylepainted foamboard of 3'x4'. Samples has to approved by the Architect before procuring the same.A) ALERT THE SECURITY BY ACTUATING MANUAL CALL POINT LOCATED AT STRATEGIC LOCATIONS. B) EVACUATE THE OCCUPANTS BY USING FIRE EXITS AND EMERGENCY EXITS ONLY, AND ASSEMBLE AT VARIOUS ASSEMBLY POITS. C) IF POSSIBLE TRY TO EXTINGUISH THE FIRE BY USING NEAREST / SUITABLE PORTABLE FIRE EXTINGUISHER OR WATER FROM NEAREST HOSE REEL. D) BE CALM AND DO NOT GIVE ANY ROOM FOR PANIC. WALK, DO NOT RUN. E) IF YOU ENCOUNTER SERIOUS DIFFICULTY IN EVACUATION ,LAY FLAT AND TRY TO ATTRACT ATTENTION OF RESCUE TEAM. F) TRY TO COVER YOUR FACE WITH A WET TOWEL TO AVOID BREATHING SMOKE OR OTHER TOXIC FUMES. ACTION BY SECURITY / RECEPTION UPON RECEIPT OF INFORMATION THROUGH FIRE ALARM OR PUBLIC ADDRESS SYSTEM. A) ALERT THE OCCUPANTS BY USING PUBLIC ADDRESS SYSTEM. B) INFORM FIRE CONTROL THROUGH ANYONE OF THE FOLLOWING PHONE NUMBERS:101 /………………….( Local fire station number) C) REFER EVACUATION PLAN.D) GUIDE THE FIRE FORCE, ON THEIR ARRIVAL TO THE SEAT OF FIRE. E) IN CASE OF CASUALTIES, CALL AMBULANCE (Local numbers:) PHONE : -----------------------.

1

-

-

... More
od100036/2022_2023 : Providing and installation in position Signage with printed SAFE ASSEMBLY AREA, of 1.25 cm height letters in red with white background.The size of the board shall be 40x30 cm and shall be fixed at the safe assembly areas demarked outside the building.

10

-

-

... More
Fire Extinguishers

-

-

-

... More
Documentation & Approval.Charges for documentation for obtaining final Certificate of approval from the Kerala State Fire & Rescue Services Dept.&State Electrical Inspectorate as per their latest amendments and checklists,3 sets of colour prinout of drawings in A1 size,ing charges etc. All the statutory expences paid to Govt. Exchequer will be reimbursed.".

1

-

-

... More
Preperation of the as built drawings of suitable size and sufficent number of copies to be submitted to local authorities and obtaining sanction from Fire and rescue department. Final NOC for the whole installation in the premises shall be obtained after testing and commissioning the proposed work. [ Obtaining sanctions is part of contract for releasing the final payments]. All statutory payments will be reimbursed on production of the original receipts.

1

-

-

... More
Supplying and fixing of Dry chemical powder type fire extinguisher of 2.0 Kgs. Capacity, with initial filling in brand new cylinder with powder coated finish, fitted with Gun metal union , dicharge hose, wall mounting bracket etc. complete, confirming to IS:2171. .

46

-

-

... More
Supply and fixing of 4.0Kg CO2 (Wheel) Type Fire Extinguisher, Design, construction and testing as per IS 2878 -2004 externally painted with PO Red Shade No. 538 of IS 5, Supplied with standard accessories.

6

-

-

... More
POWER CABLING

-

-

-

... More
Supply and Laying of below sized XLPE insulated PVC sheathed Aluminum conductor armored cabling to the incoming and outgoing of fire pump panel including necessary termination, glanding, necessary connections etc.3C x 185 sqmm on wall,floor

15

-

-

... More
3Cx 16 sq mm on wall, floor.

15

-

-

... More
MV CABLE JOINING AND END TERMINATION

-

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.3cx185 sq.mm Al cable .

2

-

-

... More
3Cx 16 sq mm on wall, floor.

2

-

-

... More
SPRINKLER HEADS

-

-

-

... More
Sprinkler Bulbs : Supply,Installation,Testing and Commissioning of 15 mm gun metal sprinkler heads Quick response standard coverage with quarts bulb and set to operate at a specified temperature as per the specifications.Temperature of operation 68 degree Celsius. pendant sprinkler type".PENDANT TYPE

356

-

-

... More
Sidewall Type .

12

-

-

... More
HVAC MACHINE SIDE

-

-

-

... More
16.15 : Suppluying and Fixing of powder costed extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.

20

-

-

... More
16.17 : Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminum with aluminum volume control dampers with anti smudge ring and removable core.

8

-

-

... More
16.18 : Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminum without volume control dampers with anti smudge ring and removable core.

8

-

-

... More
16.13 : Supply, Insulation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. GI volume control duct damper

20

-

-

... More
Communication/ Control cable between Indoor and Out door units.

330

-

-

... More
Supplying and Fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required. .Supply Air Grill with out voloume control Damper.

45

-

-

... More
SITC of Factory made fresh air dampers with louvers and control lever, filter etc as required. (as per drawing).

6

-

-

... More
Supply & Fixing of ISOWALL 50 mm thick EPS, one side GI coated sheet panels for wall and ceiling making retturn air boxing with necessary angels, sealant etc. .

170

-

-

... More
supply, installation, testing and commissioning Direct driven axial fans / Cabinet fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, single motor and flexible connection to connect with ducting / plenum. 1200 CFM/ 18mm Static.

9

-

-

... More
supply, installation, testing and commissioning Direct driven axial fans / Cabinet fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, single motor and flexible connection to connect with ducting / plenum. 100 CFM/ 15mm Static.

3

-

-

... More
Supply, Fabrication, installation and testing of the flexible ducting, complete with connecting rings, duct supports, Plenum etc as per standards and specification.Size: 100mm dia.".

50

-

-

... More
Supply and fix the following grilles and diffusers as per specifications. Machine made, powder coated, supply and return air grilles and diffusers.SIZE :150 X 150 MM Exhaust Grill.

115

-

-

... More
Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum.

10

-

-

... More
NON AC AREA DUCTING.supply & fixing of 19 mm thick Class O nitrile rubber HT insulation / EPDM Insulation of duct using with adhesive as per the recommendation of the manufacture with density 45-55kg/m3.

59

-

-

... More
supply & fixing of 9 mm thick Class O nitrile rubber HT insulation / EPDM Insulation of duct using with antimicrobial property with adhesive as per the recommendation of the manufacture with density 45-55kg/m3.

989

-

-

... More
supply & fixing of 25 mm thick acoustic insulation of AHU room using with adhesive as per the recommendation of the manufacture with density 140-180kg/m3 The wall surface shall be cleaned and required surface preparation shall be done for applying adhesive. Rubber based contact adhesive recommended by the manufacturer shall be used. The foam sheets shall be cut to require size and a thin layer of adhesive shall be applied to both the surfaces; wall and i. When it is tack dry, it is applied / stuck with enough pressure to the walls/ceiling. Minimum 5 fasteners with washer (of G.I Sheet 2.5 inch x 2.5 inch) / square meter, 4 at corners & 1 at centre shall be put immediately after sticking with the help of adhesive. The length of the fastener shall be minimum 75 mm.

290

-

-

... More
supply & fixing of 10 mm thick acoustic insulation of duct using with adhesive as per the recommendation of the manufacture with density 140-180kg/m3.

95

-

-

... More
Supply and fix chicken mesh on the ducts for protecting duct insulation as per standards

300

-

-

... More
Supply, Installation and Commissioning of Floor Mounted Inverter Type Packaged Units of specified capacities, nominal capacity condensing unit with all standard fittings, safety devices, like HP/LP cutout, single phase preventor, overload relays, R-410A Gas, vibration isolation pads etc. Suitable to work till 50 Deg ambient, Blue Fin Condenser and Corrosion Resistant Body, Wide Voltage Range 360V - 440V,Scroll Compressor-driven.Due to their inherent design characteristics, scroll compressors have very high volumetric .efficiency. They are ideal for air conditioning applications where the compression ratio is .not very high. Out door unit stand for Ducted machine ,vibration isolation pads etc. complete including all charges Anticorrosive black paint ( 2 coat epoxy painting and 2 coat primer ) etc. complete ".22 TR

2

-

-

... More
Supply, Installation and Commissioning of Floor Mounted Inverter Type Packaged Units of specified capacities, nominal capacity condensing unit with all standard fittings, safety devices, like HP/LP cutout, single phase preventor, overload relays, R-410A Gas, vibration isolation pads etc. Suitable to work till 50 Deg ambient, Blue Fin Condenser and Corrosion Resistant Body, Wide Voltage Range 360V - 440V,Scroll Compressor-driven.Due to their inherent design characteristics, scroll compressors have very high volumetric .efficiency. They are ideal for air conditioning applications where the compression ratio is .not very high. Out door unit stand for Ducted machine ,vibration isolation pads etc. complete including all charges Anticorrosive black paint ( 2 coat epoxy painting and 2 coat primer ) etc. complete ".16.5 TR

5

-

-

... More
Supply, Installation and Commissioning of Floor Mounted Inverter Type Packaged Units of specified capacities, nominal capacity condensing unit with all standard fittings, safety devices, like HP/LP cutout, single phase preventor, overload relays, R-410A Gas, vibration isolation pads etc. Suitable to work till 50 Deg ambient, Blue Fin Condenser and Corrosion Resistant Body, Wide Voltage Range 360V - 440V,Scroll Compressor-driven.Due to their inherent design characteristics, scroll compressors have very high volumetric .efficiency. They are ideal for air conditioning applications where the compression ratio is .not very high. Out door unit stand for Ducted machine ,vibration isolation pads etc. complete including all charges Anticorrosive black paint ( 2 coat epoxy painting and 2 coat primer ) etc. complete ".11 TR

2

-

-

... More
Supply, Installation and Commissioning of Ceiling Suspended Inverter Type Ducted Units of specified capacities, nominal capacity condensing unit with all standard fittings, safety devices, like HP/LP cutout, single phase preventor, overload relays, R-410A Gas, vibration isolation pads etc. Suitable to work till 50 Deg ambient, Blue Fin Condenser and Corrosion Resistant Body, Wide Voltage Range 360V - 440V,Scroll Compressor-driven.Due to their inherent design characteristics, scroll compressors have very high volumetric .efficiency. They are ideal for air conditioning applications where the compression ratio is .not very high. Out door unit stand for Ducted machine ,vibration isolation pads etc. complete including all charges Anticorrosive black paint ( 2 coat epoxy painting and 2 coat primer ) etc. complete ".22 TR

1

-

-

... More
Dismantling of Existing Package Unit , Existing Duct , Removal of existing AHU room insulation and other debris From the Site to Transporation of the Same Chitranjali Studio, Thiruvallom, Trivandrum.

1

-

-

... More
Supply, fabricate, handle and erect factory fabricated GSS ducting as per drawing, complete with all fitting such as Tee bends, special off-chutes, turning vanes, splitter dampers, ins.doors, transformation pieces slip on flanges etc. as reqd. as reqd. as per IS 655 including suspension and supporting arrangement for plenums, ducts, complete as reqd. and as per spec. (only hitech supports shall be used ) wall opening as good as same Rectangular Duct.20 GAUGE

220

-

-

... More
Supply, fabricate, handle and erect factory fabricated GSS ducting as per drawing, complete with all fitting such as Tee bends, special off-chutes, turning vanes, splitter dampers, ins.doors, transformation pieces slip on flanges etc. as reqd. as reqd. as per IS 655 including suspension and supporting arrangement for plenums, ducts, complete as reqd. and as per spec. (only hitech supports shall be used ) wall opening as good as same Rectangular Duct.22 GAUGE

270

-

-

... More
Supply, fabricate, handle and erect factory fabricated GSS ducting as per drawing, complete with all fitting such as Tee bends, special off-chutes, turning vanes, splitter dampers, ins.doors, transformation pieces slip on flanges etc. as reqd. as reqd. as per IS 655 including suspension and supporting arrangement for plenums, ducts, complete as reqd. and as per spec. (only hitech supports shall be used ) wall opening as good as same Rectangular Duct.24 GAUGE

600

-

-

... More
Supply,Installation,Testing and Commissioning of following size . Insulated PVC drain pipe from AHU drain pans to nearest floor drain complete with interconnection, flanges, elbows, tees, nuts, U-trap etc. The insulation shall be 6 mm thick closed cell class O Nitirile Rubber foam insulation . (25 mm outer dia PVC ).

80

-

-

... More
Supply,Installation,Testing and Commissioning of following size . Insulated PVC drain pipe from AHU drain pans to nearest floor drain complete with interconnection, flanges, elbows, tees, nuts, U-trap etc. The insulation shall be 6 mm thick closed cell class O Nitirile Rubber foam insulation . (32 mm Outer dia PVC ).

100

-

-

... More
SITC of Refrigerant piping (Suction & Discharge) Soft drawn Copper tube of suitable sizes,with copper elbows,tees, Tubular Nitrile Insulations etc as required ( For 22TR package - 7/8 and 1/2 x 2), ( For 16.5TR package - 7/8 and 1/2 + 5/8 and 3/8 ), ( For 11TR package 7/8 and 1/2 ), ( For 22TR Ducted - 1 1/8 and 1/2 x 2nos ).Refrigerant piping for All package and ducted units.

320

-

-

... More
SITC of Refrigerant piping (Suction & Discharge) Soft drawn Copper tube of suitable sizes, with copper elbows, tees, Tubular Nitrile Insulations etc as required . ( For 3TR split - 5/8 and 3/8 ), ( For 2TR split 5/8 and 3/8 ), ( For 1.5TR split 1/2 and 1/4 ), (For 1TR 1/2 and 1/4 ).Refrigerant piping for Hi wall split (Above 3 meter).

110

-

-

... More
Supply and Fixing Readymade out door stand for Hi wall split including all charges etc. complete and Anticorrosive black paint.

13

-

-

... More
Supply, Installation and Commissioning of Inverter Hi wall unit with rotary compressor. The units should be complete with indoor unit, Condensing Unit, Copper condenser coil, controls, microprocessor control panel, wiring, etc.The unit must run on green gas refrigerant ( R32) only. " .3 TR.

2

-

-

... More
Supply, Installation and Commissioning of Inverter Hi wall unit with rotary compressor. The units should be complete with indoor unit, Condensing Unit, Copper condenser coil, controls, microprocessor control panel, wiring, etc.The unit must run on green gas refrigerant ( R32) only. ".2TR

4

-

-

... More
Supply, Installation and Commissioning of Inverter Hi wall unit with rotary compressor. The units should be complete with indoor unit, Condensing Unit, Copper condenser coil, controls, microprocessor control panel, wiring, etc.The unit must run on green gas refrigerant ( R32) only. ".1.5 TR

4

-

-

... More
Supply, Installation and Commissioning of Inverter Hi wall unit with rotary compressor. The units should be complete with indoor unit, Condensing Unit, Copper condenser coil, controls, microprocessor control panel, wiring, etc.The unit must run on green gas refrigerant ( R32) only. ".1 TR

3

-

-

... More
CEILING TREATMENT

-

-

-

... More
od122162/2022_2023 : FIRST CEILING ON ROOF IN PLAIN GYPUM & MICRON.Providing & fixing first ceiling on roof in 01 layer of 12.5mm thk Indian Gypsum.Plain board with 50mm thk 1000gsm density micron in between G.I frame work .FRAME - G.I.frame fabricated with 45 x 15 x 0.8 mm thk Intermediate 'C' channel. @ 900mm c/c in one Direction & Ceiling sections 80 x 26 x 0.5 @ 450 mm c/c in .other direction including perimeter channel as required & 25x25x0.55mm ceiling angle .securely fixed to structural soffit hangers/purlins @ 1220mm c/c, last ceiling angle not .more than 600mm from adjacent wall, connecting clips etc as required with 50mm thk .1000gsm density micron, including machine screw, levelling & scaffolding, etc .complete. Work will be carried out as 'per drg & instruction of Acoustc consultant / .Site Engineer /Architect.FINISH: Entire frame /Micron shall be cover with 01 Layer of 12.5mm thk Plain Gypsum.JOINTS - All joints of panels filled and finished with India Gypsum jointing compound.jointing tapes etc. complete as per manufacturer specification for joint.NOTE :All the frame work to be considered of Gypsum India company .

894

-

-

... More
od122267/2022_2023 : PERFORATED GYPSUM TILE FALSE CEILING.Providing & fixing false ceiling in 01 layer of 595 x 595 x 12.5mm thk perforated gypsum.tile with 50mm thk 1000gsm denisty micron in between G.I frame work in RP Tissue bag.FRAME - G.I.frame fabricated with 45 x 15 x 0.8 mm thk Intermediate 'C' channel. @ 1220mm c/c in one Direction & Ceiling sections 80 x 26 x 0.5 @ 300mm c/c in .other direction including perimeter channel as required & 25x25x0.55mm ceiling angle .securely fixed to structural truss/members above @ 1220mm c/c, last ceiling angle not .more than 610 mm from adjacent wall, connecting clips etc as required with 50mm thk .1000 gsm density micron in Black RP Tissue bag, including scaffolding, cutting of spot .light, AC diffuser, return air grill, Sprinkler & any other services cutout & providing .necessary 6mm thk ply support & redoing the same in good finish etc complete.Work .will be carried out as per drg & instruction of Acoustc consultant / Site Engineer /Architect.

793

-

-

... More
od122280/2022_2023 : PLAIN GYPSUM BOARD FALSE CEILING.Providing & fixing false ceiling in 01 layer of 12.5mm thk Indian Gypsum Plain board .with 50mm thk 1000gsm denisty micron in between G.I frame work .FRAME - G.I.frame fabricated with 45 x 15 x 0.8 mm thk Intermediate 'C' channel. @ 1220mm c/c in one Direction & Ceiling sections 80 x 26 x 0.5 @ 450mm c/c in .other direction including perimeter channel as required & 25x25x0.55mm ceiling angle .securely fixed to structural truss/members above @ 1220mm c/c, last ceiling angle not .more than 610 mm from adjacent wall, connecting clips etc as required with 50mm thk .1000 gsm density micron in Black RP Tissue bag, including scaffolding, cutting of spot .light, AC diffuser, return air grill, Sprinkler & any other services cutout & providing .necessary 6mm thk ply support & redoing the same in good finish etc complete.Work .will be carried out as per drg & instruction of Acoustc consultant / Site Engineer /Architect.JOINTS - All joints of panels filled and finished with India Gypsum jointing compound.jointing tapes etc.complete as per manufacturer specification for joint.TOP COAT – Entire face of ceiling finished with two coats of top coat as per .manufacturers specifications. Three coats of matt paint colour as approved by Architect.till the satisfaction of site Engineer.

127

-

-

... More
od122305/2022_2023 : MODULAR TILE CEILING IN EXIT PASSAGE.Providing & fixing of the acoustical mineral fiber ceiling tile of 0.75NRC value on the 'T'. 'T' Grid system from the Armstrong, AMF, Ecophon or any euivalent approved in the .exit passege, including cutting of spot light , Sprinkler & any other related services cut out.providing necessary 6mm thk ply support & redoing the same in good finish complete.Work will be carried out as per drg & instruction of acoustic consultant /site Engineer /.Architect.

50

-

-

... More
od122312/2022_2023 : :ACOUSTICAL LINING OF BACK WALL OF SCREEN IN SOUND BOX.(AS MARKED IN THE.DRAWING Providing & fixing of 50mm thk 1000gsm density micron in between G.I frame work.finish with Black Crape fabric as approved FRAME - G.I.frame fabricated with 50 x 37.5 x 0.5 G.I 'C' section @.1220mm c/c in horizontal direction fixed to or away from wall surface on necessary 50 x 50mm wooden 'T'.dutta support with 50mm Air gap, above 'C' section have Ceiling sections of 80 x 26 x 0.5 @ 400mm c/c in.vertical direction with 50mm thk 1000gsm density micron in between 'C' section frame fixed with chicken.mesh backing of G.I 12x12mm square of 24 guage (as per approved sample), including scaffolding, machine.screw, etc complete.Work 'will be carried out as per drg & instruction of Acoustic consultant/ Site Engineer./Architect.FINISH: Entire frame /Micron shall be finish with (FR) Black Crape fabric as approved.NOTE.PRICE EST NO:2022/9379.printed on 05-08-2022 14:16:09 page 5.Other Engineering Organisations.P R I C E.:All the wood shall be used will be coated with Fire painting & necessary Anti-termite treatment & All the.frame work to be considered of Gypsum India company & All the Wooden dutta will have 100x100x12mm thk.(Insu Sound-Bcap rubber of Supreme ) behind between wall and wooden dutta

127

-

-

... More
od122333/2022_2023 : ACOUSTICAL PANELING BEHIND OF SCREEN IN 'L' SHAPE AT .CORNER JUNCTION OF WALL.(BOTH SIDE) IN AUDI -01.(AS MARKED IN THE DRAWING - WF-02 Providing & fixing 01 layer of 595 x 595 x 12.5mm thk perfoated gypsum tile with 50mm.thk 1000gsm density micron in between G.I frame work finish with Black water base paint.as marked in drawing (1200 x 1200mm in 'L' shape).FRAME - G.I.frame fabricated with 50 x 37.5 x 0.5 G.I 'C' section @ 1220mm c/c in.horizontal direction fixed to or away from wall surface on necessary 50 x 50mm wooden .T' dutta support with 50mm Air gap, above 'C' section have Ceiling sections of 80 x .26 x 0.5 @ 400mm c/c in vertical direction with 50mm thk 1000gsm density micron in .between 'C' section frame fixed with chicken mesh backing of G.I 12x12mm square of 24.guage (as per approved sample), including scaffolding, machine screw, etc complete.Work.will be carried out as per drg & instruction of Acoustic consultant/ Site Engineer /Architect.FINISH: Perfoated gypsum tile shall be finish with Black Water base paint as approved .NOTE :All the wood shall be used will be coated with Fire painting & necessary Anti-.termite treatment & All the frame work to be considered of Gypsum India company .& All the Wooden dutta will have 100x100x12mm thk (Insu Sound-Bcap rubber of .Supreme ) behind between wall and wooden dutta.

68

-

-

... More
od122383/2022_2023 : SIDE WALL 'E' BOARD SPLAY PANELING UP TO 2100MM AVG HEIGHT.(AS MARKED IN THE.DRAWING - WF-03) Providing & fixing 1 layer of 08mm thk site Perforated (08mm Random holes) 'E' board .with 50mm thk 1000gsm denisty micron in between G.I frame work as per drawing.FRAME - G.I.frame fabricated with 50 x 37.5 x 0.5 G.I 'C' section @ 1220mm c/c in.horizontal direction fixed to or away from wall surface on necessary 50 x 50mm wooden .T' dutta support with 50mm Air gap, above 'C' section have Ceiling sections of 80 x .26 x 0.5 @ 400mm c/c in vertical direction with 50mm thk 1000gsm density micron in .between 'C' section frame fixed with chicken mesh backing of G.I 12x12mm square of 24.guage (as per approved sample), including scaffolding, machine screw, etc complete.Work.will be carried out as per drg & instruction of Acoustic consultant/ Site Engineer /Architect.NOTE :All the wood shall be used will be coated with Fire painting & necessary Anti-.termite treatment & All the frame work to be considered of Gypsum India company .& All the Wooden dutta will have 100x100x12mm thk (Insu Sound-Bcap rubber of .Supreme ) behind between wall and wooden dutta.

188

-

-

... More
od122441/2022_2023 : SIDE WALL PERFORATED GYPSUM TILE SPLAY PANELLING ABOVE .2100MM AVG HEIGHT.(AS MARKED IN THE DRAWING - WF-04) Providing & fixing 1 layer of 12.5mm thk Perforated gypum tile with 50mm thk 1000gsm.density micron in between G.I frame work as per drawing.FRAME - G.I.frame fabricated with 50 x 37.5 x 0.5 G.I 'C' section @ 1220mm c/c in.horizontal direction fixed to or away from wall surface on necessary 50 x 50mm wooden .T' dutta support with 50mm Air gap, above 'C' section have Ceiling sections of 80 x .26 x 0.5 @ 400mm c/c in vertical direction with 50mm thk 1000gsm density micron in .between 'C' section frame fixed with chicken mesh backing of G.I 12x12mm square of 24.guage (as per approved sample), including scaffolding, machine screw, etc complete.Work.will be carried out as per drg & instruction of Acoustic consultant/ Site Engineer /Architect.NOTE :All the wood shall be used will be coated with Fire painting & necessary Anti-.termite treatment & All the frame work to be considered of Gypsum India company .& All the Wooden dutta will have 100x100x12mm thk (Insu Sound-Bcap rubber of .Supreme ) behind between wall and wooden dutta.

418

-

-

... More
od122659/2022_2023 : REAR WALL 'E' BOARD PANELING UP TO 1200MM HEIGHT.(AS MARKED IN THE DRAWING -.WF-03) Providing & fixing 1 layer of 08mm thk site Perforated (08mm Random holes) 'E' board .with 50mm thk 1000gsm denisty micron in between G.I frame work as per drawing.FRAME - G.I.frame fabricated with 50 x 37.5 x 0.5 G.I 'C' section @ 1220mm c/c in.horizontal direction fixed to or away from wall surface on necessary 50 x 50mm wooden .T' dutta support with 50mm Air gap, above 'C' section have Ceiling sections of 80 x .26 x 0.5 @ 400mm c/c in vertical direction with 50mm thk 1000gsm density micron in .between 'C' section frame fixed with chicken mesh backing of G.I 12x12mm square of 24.guage (as per approved sample), including scaffolding, machine screw, etc complete.Work.will be carried out as per drg & instruction of Acoustic consultant/ Site Engineer /Architect.NOTE :All the wood shall be used will be coated with Fire painting & necessary Anti-.termite treatment & All the frame work to be considered of Gypsum India company .& All the Wooden dutta will have 100x100x12mm thk (Insu Sound-Bcap rubber of .Supreme ) behind between wall and wooden dutta.

88

-

-

... More
od122683/2022_2023 : REAR WALL G.I. FRAME PANELLING ABOVE 1200MM HEIGHT.G.I. FRAME PANELLING ABOVE.MASKING IN SLOPE.(AS MARKED IN THE DRAWING - WF-05) Providing & fixing G.I frame work paneling with 50mm thk 1000gsm denisty micron in.between G.I frame work as per drawing.FRAME - G.I.frame fabricated with 50 x 37.5 x 0.5 G.I 'C' section @ 1220mm c/c in.horizontal direction fixed to or away from wall surface on necessary 50 x 50mm wooden .T' dutta support with 50mm Air gap, above 'C' section have Ceiling sections of 80 x .26 x 0.5 @ 400mm c/c in vertical direction with 50mm thk 1000gsm density micron in .between 'C' section frame fixed with chicken mesh backing of G.I 12x12mm square of 24.guage (as per approved sample), including scaffolding, machine screw, etc complete.Work.will be carried out as per drg & instruction of Acoustic consultant/ Site Engineer /Architect.NOTE :All the wood shall be used will be coated with Fire painting & necessary Anti-.termite treatment & All the frame work to be considered of Gypsum India company .& All the Wooden dutta will have 100x100x12mm thk (Insu Sound-Bcap rubber of .Supreme ) behind between wall and wooden dutta.

133

-

-

... More
od122782/2022_2023 : SHUTTER IN MASKING FOR SOUND BOX ACCESS.Providing & fixing of the 19mm thk FR ply Shutter in Black masking for Sound box .access finished with Black PP Fabric from outside & Black Paint from inside, including.the necessary frame for fixing shutter & hinges-02 no's, Concealed Handle, Bolkage etc .complete. Work will be carried out as per drg & instruction of acoustic consultant /Site .Engineer/Architect. Shutter size -750 X 1200mm.

4

-

-

... More
od122795/2022_2023 : SKIRTING IN BLACK LAMINATE FINISH.Providing / fixing 200mm high skirting in 19mm thk ply fixed on existing frame work.flushed with above panelling,Skirting finish with 1.5mm thk Black Laminate as approve.by Architect till satisfaction including cutouts for power sockets.Work will be carried.out as per drg & instruction of acoustic consultant,Site Engineer / Architect.Basic Rate of Laminate- = Rs - 650/sq.mt.NOTE :All the wood shall be used will be coated with Fire painting & necessary Anti-.termite treatment .

108

-

-

... More
od122822/2022_2023 : CINEMA ACOUSTICAL DOOR FRAME- (D1).Providing / Fixing 200mm x 150mm thk teak wood door frame with double rebate as .per detail drawing including MS hold fast in plumb line and one coat of Black japan paint.& Anti termite treatment on frame, etc complete.Work will be carried out as per drg &.instruction of acoustic consultant / Site Engineer / Architect.

1.64

-

-

... More
od122875/2022_2023 : CINEMA ACOUSTICAL DOOR SHUTTER - 125 MM THK (D1).Providing & making of the 125mm thk Acoustical Door shutter in hard wood frame of.75x37.5mm all around both side and intermediate frame of 50x37.5mm @ 600 mm c/c.in both direction, keep 50mm thk 1000gsm density micron in between frame both side.with 01 layer of 10kg/m2 Tec sound & 01 layer of 12.5mm thk plain gypsum board in.between both hardwood frame work, Door Shutter shall be finished with 1.5mm thk .Laminate as per Architect, design drawing & pattern. All the edges of the shutter shall.be finished with T.W lapping putty as per detail. Door seal (RAVEN.RP-85) Magnetic seal lining on three side of the frame rebate as per drawings. Work will.be carried out as per drg & instruction of acoustic consultant / Site Engineer / Architect.

48

-

-

... More
od126685/2022_2023 : 75 x 75MM 'L' PELMET IN PLY IN SPLAY PANELING.Providing & Fixing 75 x 75 x 12mm thk (FR) ply pelmet in 'L' shape with necessay.support on existing frame work in shape & design as per Architect drawing, Pelmet .shall be finished with paint from inside & Fabric as per design from outside as approved .by Architect including scaffolding etc complete. Work will be carried out as per drg & .instruction of Acoustic consultant / Site Engineer /Architect.

240

-

-

... More
od150689/2022_2023 : BLACK PP FABRIC MASKING .(AS MARKED IN THE DRAWING - WF-06).Providing & fixing G.I.frame work for Black PP fabric masking as per drawing.FRAME - G.I.frame fabricated with 50 x 37.5.x 0.5 G.I 'C' section @ 1220mm c/c in.horizontal direction fixed to or away from wall surface with top.& bottom section and .necessary 50 x 50mm wooden dutta if any required as per site condition,.Above 'C' .section have Ceiling sections of 80 x 26 x 0.5 @ 400mm c/c in vertical direction.including.scaffolding, machine screw , etc complete.Work will be carried out as per drg.&.instruction of Acoustic consultant / Site Engineer /Architect.FINISH: Black PP fabric shall be.finish on 75x12mm (FR) ply patty as per shapes,pattern.as mentioned in the drawing on G.I frame.work.NOTE :All the wood shall be used will be coated with Fire painting & necessary Anti-.termite.treatment & All the frame work to be considered of Gypsum India company .NOTE : Install PP fabric.without wrinkles or folds maintaining horizontal/vertical.alignment of warp/ woof of fabric using.technique that will not damage the finish of fabric.

51

-

-

... More
ACCESSORIES

-

-

-

... More
od122886/2022_2023 : PORT HOLE WINDOW FIXED.Providing & fixing of the port hole window 1000mm x 800mm or as per designed in 19.mm fire proof ply with necessary saalwood frame, Ply shall be finished with 1.5mm.thk Black Laminate including 12mm thk clear no reflective Modi flat glass with 'U'.rubber all around the glass complete in line & level etc,Work will be carried out as per.drg & instruction of acoustic consultant / Site Engineer / Architect.NOTE :All the wood shall be used will be coated with Fire painting & necessary. Anti-termite treatment.

2

-

-

... More
od124049/2022_2023 : LABOUR CHARGES FOR SPEAKER BRACKET FIXING ON WALL.Labour charges for fixing surround speaker bracket on existing ply base in side wall .& rear wall as per detail including scaffolding, levelling etc complete. Work will be.carried out as per drg & instruction of acoustic consultant /Site Engineer /Architect.

44

-

-

... More
od124051/2022_2023 : PLY BATTEN FOR STEP LIGHT BACKING.Providing & fixing of the 125mm wide x 12mm thk ply batten fixed on the edge of the.cinema steps for supporting the step light. Edge of the ply shall be well projected.during the construction of the cinema steps. work will be carried out as per drg &.instruction of acoustic consultant / Site Engineer / Architect.

130

-

-

... More
FINISHING TREATMENT

-

-

-

... More
od124061/2022_2023 : FABRIC ON GRIPPER SYSTEM ( SIDE WALL & REAR WALL ).Providing & fixing stretch fabric gripper system (UK) UPVC Grippers,standard,cove.mono,edge, but as required by design & manufacture's specifications.CORE - Fire retardant compressible polyster padding of 25mm thk including .scaffolding etc complete.Work will be carried out as per drg & instruction of Acoustic.Consultant/ Site Engineer /Architect.FRAME : Gripper fix on 75 x 12mm ply (fire retardant) patty with 25 mm thk.Polyster padding as required by design.INSTALLATION:Installation in accordance.with drawings and manufacturer's instruction. Installation of grippers in maximum .length possible. From end-to-end butt joints with hairline not be visible in finished.work. Install grippers so that joints between core material & grippers are not .visible in finished work, rebate edge of rigid core material for flush fit.Install .fabric without wrinkles or folds, maintaining horizontal/ vertical alignment of .warp/woof of fabric, force fabric edges into clamping jaws, using tools and .techniques that will not damage finish of the fabric complete to the satisfaction.of the site Engineer-In-Charge. SUBMITTALS : Shop drawings indicating.location, size, type,including frame, core & fabric finish components, for each.panel in project. Drgs indicating construction details of interface with adjacent.construction. The rates shall includes the shapes, pattern as mentioned in the.drawing indicating graphics if any.

827

-

-

... More
od124068/2022_2023 : BLACK CRAPE FABRIC FIXING ON PERFORATED GYPUM CEILING.Providing & fixing of Black Crape fabric on perforated gypsum ceiling tile with 75x12mm .thk (FR) Ply patty as per grooves & pattern mentioned in drawing in line & level .including scaffolding etc complete, Work will be carried out as per drg & instruction of .Acoustic Consultant / Site Engineer /Architect. Basic Rate of Fabric- = Rs - 225/mtr.NOTE : Install Crape fabric without wrinkles or folds maintaining horizontal/vertical.alignment of warp/ woof of fabric using technique that will not damage the finish of fabric.

793

-

-

... More
od124074/2022_2023 : RIBBED CARPET FINISHED ON STAGE WALL BELOW SCREEN IN AUDI-01.Providing & applying P.O.P punning on stage wall surface maintaining line & level, &.preparing the surface for pasting Black Ribbed carpet on level surface with SR998 or.equivalent Adhesive material suggested by manufacturer etc complete as per drawing.including scaffolding etc complete, Work will be carried out as per drg & instruction of .Acoustic Consultant / Site Engineer /Architect. Basic Rate of Carpet = Rs - 240/mtr.NOTE : Install ribbed Carpet without wrinkles or folds maintaining horizontal/vertical.alignment of warp/ woof of fabric using technique that will not damage the finish .

110

-

-

... More
od124246/2022_2023 : FIXING PERFORATED WHITE SCREEN ON M.S FRAME.Fixing white perforated Galalite screen on the M.S screen frame including scaffolding.Work will be carried out as per drg & instruction of acoustic consultant, Site Engineer./Architect. SCREEN WILL BE SUPPLY BY CLIENT.

136

-

-

... More
od124548/2022_2023 : PAINTING (3 COATS OF PLASTIC PAINT) AS REQUIRED.Applying 3coats of Plastic paint of approved make & shade of Asian paint or Nerolac.or ICI Dulux, Surface shall be clean and sanding by sand paper & applying one coat .paint & putty & again sanding & leveling & two coats of paint till approved & .satisfaction of Architect to shade colour including scaffolding etc complete work will .be carried out as per drg & instruction of acoustic consultant /Site Engineer/Architect.

175

-

-

... More
od148490/2022_2023 : >Providing & fixing of 800gsm cut pile carpet with 06mm thk underlay to be fixed on..cinema tiers as per design & drawing of Architect, Surface shall be clean properly before..installing carpet, Carpet shall be fix with adhesive as per manufacture specifications, in.perfect.line & level , no joints should be visible, All as per approved design, shade & .make etc complete.Complete work will be carried out as per drg & instruction of site.Engineer/Architect, Basic Rate of.Carpet- = Rs - 800/sq.m

1080

-

-

... More
FABRICATION WORK

-

-

-

... More
od124677/2022_2023 : MS SCREEN FRAME SUPPORTING FROM FLOOR & SLAB.Providing & Installing screen supporting from floor in 2mm thk 18 guage M.S pipe 50mm.dia external frame and 25mm dia internal frame including Elbow as per detail drawing with .100x100x19mm thk (Insu Sound-Bcap rubber of Supreme) backing on floor & slab above .behind base plate, MS pipe shall be finished with Black Paint, Work will be carried out as.per drg & instruction of Acoustic consultant, site Engineer/Architect.

130

-

-

... More
od124842/2022_2023 : MS SPEAKER PLATFORM SUPPORTING FROM WALL.Providing & fixing of M.S speaker platform in M.S angle of 75mm X 75mm as per .drg with 02 layers of 19mm thk Ply above frame with fabrication, levelling etc .complete including one coat of red oxide paint and two coat of Black paint as approved.M.S. angle will be supported at 1200mm c/c with the 'L' bracket, The bracket will have.12mm thk (Insu Sound-Bcap rubber of Supreme) in between wall & bracket. The .depth of the platform will be as per site.Work will be carried out as per drg &.instruction of acoustic consultant /Site Engineer /Architect.

76

-

-

... More
od125285/2022_2023 : M.S PIPE HAND RAIL.Providing & fixing of the Black color powder coated M.S pipe hand railing of 50mm .dia along the wall fixed with 100 x 100 x 6mm thk Base plate support system with .100 x 100 x 12mm thk (Insu Sound-Bcap rubber of Supreme), behind base plate on the .wall @ 1200mm c/c in line & level as per site, etc complete. Work will be carried out as .per drg & instruction of acoustic consultant / Site Engineer /Architect.

50

-

-

... More
od125309/2022_2023 : MS SUPPORT SYSTEM.Providing & fixing of M.S 'C' channel of 100 x 50 x 6mm @ 1200mm C/C as per.drawing & wherever required as per site requirement for supporting A/C ducts, False .ceiling with necessary support from 'I' beam including weilding, grinding, scaffolding, .Channel shall be finished with 01 coat of Red oxide & 02 coat of Black Paint etc.complete. Work will be carried out as per drg & instruction of structural consultant./site Engineer/Architect.

3500

-

-

... More
od125340/2022_2023 : MS SPEAKER PLATFORM SUPPORTING FROM WALL FOR ATMOS.Providing & fixing of the M.S speaker platform in M.S angle 75x 75mm as per .drawing for the sub woofer Base for Atmos speaker supported from the wall with 12mm.thk (Insu Sound-Bcap rubber of Supreme) between the M.S frame & wall to avoid .Vibrational sound in structure, including 2 layers of 19mm thk ply & 01 layer of 19mm thk.rigid rubber on ply complete with necessary weilding, grinding levelling etc. complete .including one coat of Red oxide paint and two coat of Black paint as approved by .Architect, Vendor to give necessary shop drawing for the same for structural consultant .approval Work will be carried out as per drg & instruction of acoustic consultant/Site .Engineer/Architect ( Platform size : 1350 X 1000mm).

8

-

-

... More
od125372/2022_2023 : M.S BRACKET FOR ATMOS SPEAKER BASE FOR CEILING.Providing & fixing of the M.S bracket in square box pipe of 50x50mm for the speaker.bracket for Atmos speaker from the ceiling to be supported from the sub frame of M.S.truss girder with necessary base plate & 12mm thk(Insu Sound-Bcap rubber of Supreme).at Junction to avoid Vibrational sound in structure, including necessary weilding,grinding.finished with 1coat of Red oxide & 2 coat of Black Paint etc complete.Vendor to.give necessary shop drawing for the same for structural consultant approval Work will.be carried out as per drg & instruction of acoustic consultant/Site Engineer/Architect .Base Size : 375 x 375mm.

40

-

-

... More
od125396/2022_2023 : FIRE CABINETS.Providing & Fabricating 1200mm x 900mm x 450mm(for tender to be provided .as per system supplier’s drawings) fire cabinet boxes in all the theatres made from.12mm thk 'E'-board finished with 1.5mm matt Black laminate. 100x30 Salwood .shutter frame. 6mm Modi Flat Clear Glass with frosted film fitted in the frame with. 6mm neoprene ‘U’ gaskets. 2 UNION make heavy duty SS hinges. 1 UNION.make heavy duty matt finish SS handle. Painting inside surfaces of cabinet with.Matt Black water based paint etc complete for intended use in every respect, Work.will be carried out as per drg & instruction of MEP consultant / Site Engineer/Architect .

4

-

-

... More
ISOLATION TREATMENT

-

-

-

... More
od126268/2022_2023 : THX WALL BEHIND SCREEN.Providing & fixing - 03 layer of 12.5mm thk plain gypsum board One side of M.S stud .section frame work in staggered joint screwed to stud frame as per drawing.FRAME - GI Stud frame fabricated with 146 x 34 x 36 x .55 'C' section @ 600 mm c/c.in one diection with necessary 50 x 50mm wooden 'T' support as required as per site.condition, including 75mm thk 1000gsm density micron fixed with chicken mesh back of.G.I 12x12mm square of 24 guage & Black Crape fabric from back side of framing,.including scaffolding etc complete. Work will be carried out as per drg & instruction of.Acoustic consultant/ Site Engineer / Architect.JOINTS - All joints of Gypsum panels filled and finished with India Gypsum jointing.compound, jointing tapes etc.complete as per manufacturer specification for joint.TOP COAT – Final Layer of Gypsum shall be finished with Black Paint as approved by.Architect / till the satisfaction of site Engineer.

150

-

-

... More
od126311/2022_2023 : SURROUND SPEAKER ISOLATION .Providing & fixing of size 450 x 300 x 19mm thk Ply for the speaker bracket fixing on .wall with 100 x100 x 19mm thk (Insu Sound-Bcap rubber of Supreme) 04 nos in .between ply & wall as per detail etc complete. Work will be carried out as per drg &.instruction of acoustic consultant /Site Engineer /Architect.

44

-

-

... More
od126318/2022_2023 : ISOLATION BASE FOR SUBWOOFER SPEAKER .Providing & making of the isolation base for the subwoofer as per drg in 02 layer of .19mm thk ply & in between ply have 01 layer of 100 x 100 x 25mm thk rigid rubber.pads on all four sides & keep 25 mm thk 32 kg/m3 density Glass wool in between ply.The base shall be covered with Black resin & shall be mounted on 2 layer of 150 x 150.x 25 mm thk rubber of sylomor @ 04 corners, etc complete as per detail. Work will be .carried out as per drg & instruction of acoustic consultant /Site Engineer/Architect. .( Isolation Base size = 1200mm X 900mm ).

2

-

-

... More
od126323/2022_2023 : ISOLATION BASE FOR MAIN SPEAKER .Providing & making of the isolation base for the main speaker as per drg in 02 layer .of 19mm thk ply & in between ply have 01 layer of 100 x 100 x 25mm thk rigid rubber.pads on all four sides & keep 25 mm thk 32kg/m3 gsm density glass wool in between.ply.Base shall be covered with Black resin & shall be mounted on 2 layer of 150 x 150.x 25mm thk rubber of sylomor @ 04 corners, etc complete as per detail. Work will be .carried out as per drg & instruction of acoustic consultant /Site Engineer/Architect. .( Isolation Base size = 750mm X 600mm ).

6

-

-

... More
ELECTRICAL

-

-

-

... More
Transformer -400 KVA: Supply installation testing & commissioning of 11KV/433V, 3 phase,400kVA vector DYN-11 dry type indoor transformer with tappings from +5% to -10% in steps of 2.5%, changeable on offcircuit by tap links provided, with WTI & LV terminals suitable for 2 runs of PVCA cable, HV terminals connected with incoming suitable for XLPE cable, with provision for fixing TOD Meter and output connected to 11KV seal off bushings to the transformer

1

-

-

... More
HT CABLE SUPPLY & LAYING: Supply of following 11kV (E) grade XLPE insulated PVC sheathed compact circular armoured aluminium conductor HT power cable, insulation screened with extruded semi conducting compound in combination with copper tape suitable for 11kV earthed system confirming to relavent standard. 3cx300sq.mm XLPE Cable

75

-

-

... More
Laying of following 11kV (E) grade XLPE insulated PVC sheathed compact circular armoured aluminium conductor HT power cable, insulation screened with extruded semi conducting compound in separate existing cable tray/ on surface using factory made clamps and the spacing between clamps will not exceed 60cm. Above 120 sq. mm and upto 400 sq. mm

15

-

-

... More
320kVA DIESEL GENERATOR Supply installation testing & commissioning of 320KVA/250KW, Diesel Generating Set with CPCB approved acoustic enclosure comprising of : “Cummins” Model QSN14-G2 Diesel engine developing 475 HP at 1500RPM, coupled with 320KVA/250 KWA Alternator 415 Volts complete with standard accessories mounted on Channel Iron Base Frame, Fuel Tank, Standard Control panel suitable with Modbus compactability for BMS integration and ATS operations.

1

-

-

... More
EXHAUST PIPES Supply, erection, commissioning of additional length of exhaust pipes with long radius bend from residential silencer with necessary clamps, fixtures, civil works and painted with heat resistant, rust proof, bituminous paint of approved colors to a maximum of 10 m in stages of following sizes including suitable rain cap for top to avoid rain water entry. The distance between exhaust pipe at top and rain cap should be higher than diameter of pipe. It is also recommended that horizontal run of exhaust piping should slope downwards away from engine to the condensate trap. Silencer should be installed with drain plug at bottom. Fixing shall be done with proper clamps, expansion bolts, and all other acessories as instructed by the Engineer and the rate inclusive of all minor civil works required, bolts, clamps etc as required for istallation. Support to exhaust piping should be done in such a manner that load of exhaust piping is not exerted to turbocharger. Exhaust pipe height shall be 3m more than the top of any adjacent building withing 10m radius of the exhaust. 150mm dia

17

-

-

... More
Supply & providing insulation for exhaust pipe with thermal insulation and providing aluminium cladding as per standards.

17

-

-

... More
DG set commisioning including Trial run of DG set for 6 hrs. on no-load and variable load condition and to record the parameters as per prescribed format as per manufacturer standards. Cost of consumable ( full tank fuel, oil, lube oil, etc.) to be borne by Contractor.

1

-

-

... More
Supplying and fixing vertical 2 inch GI Pipe 4-6 mtr height and truss work using 3inch X 1.5Inch size pipe also fixing the purling over the truss work( Size of Purlin- 1.5Inch X 0.75 Inch ) and covered with 0.35mm traffod sheet including two coat of paint over two layer of metal Primer

18

-

-

... More
LT CABLE SUPPLY: Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date 3.5cx400sq.mm Al Cable.

45

-

-

... More
LT CABLE SUPPLY: Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 3.5cx300sq.mm Al Cable

40

-

-

... More
LT CABLE SUPPLY: Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 3.5cx240sq.mm Al Cable

35

-

-

... More
LT CABLE SUPPLY: Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 3.5cx185sq.mm Al Cable

50

-

-

... More
LT CABLE SUPPLY: Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 3.5cx120sq.mm Al Cable

35

-

-

... More
LT CABLE SUPPLY: Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 3.5cx70sq.mm Al Cable

25

-

-

... More
LT CABLE SUPPLY: Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 3.5cx50sq.mm Al Cable

20

-

-

... More
LT CABLE SUPPLY: Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 3.5cx35sq.mm Al Cable

70

-

-

... More
LT CABLE SUPPLY: Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 4cx25sq.mm Al Cable

200

-

-

... More
LT CABLE SUPPLY: Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 4cx16sq.mm Al Cable

220

-

-

... More
LT CABLE SUPPLY: Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 4cx10sq.mm Al Cable

30

-

-

... More
LT CABLE SUPPLY: Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 4x6sq.mm Al Cable

180

-

-

... More
LT CABLE SUPPLY: Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 3x4sq.mm Al Cable

40

-

-

... More
LT CABLE SUPPLY: Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 2x2.5sq.mm CU flexible Cable

25

-

-

... More
LT CABLE SUPPLY: Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 1x16sq.mm CU flexible Cable

110

-

-

... More
LT CABLE SUPPLY: Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 1x6sq.mm CU flexible Cable

130

-

-

... More
Supply of the following size Control Copper Cables, Solid Copper conductor upto 6sqmm balance Stranded, XLPE Insulated, cores laid up, PVC tape innersheathed for Multicore Cables, Unarmoured/Armour (Glavanised wire or galvanised steel strip), extruded PVC Sheathed, 650/1100 V grade as per IS 7098 (Part 1) 1988. 12x2.5sq.mm Cu Control Cable

50

-

-

... More
Supply of the following size Control Copper Cables, Solid Copper conductor upto 6sqmm balance Stranded, XLPE Insulated, cores laid up, PVC tape innersheathed for Multicore Cables, Unarmoured/Armour (Glavanised wire or galvanised steel strip), extruded PVC Sheathed, 650/1100 V grade as per IS 7098 (Part 1) 1988. 2cx2.5sq.mm Cu Control Cable

50

-

-

... More
Supply and making end termination with brass double compression gland, earth clip and aluminum lugs/ Cu lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminum conductor cable of 1.1kV Grade as reqiured. 4Cx6sq.mm Al Cable

20

-

-

... More
Supply and making end termination with brass double compression gland, earth clip and aluminum lugs/ Cu lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminum conductor cable of 1.1kV Grade as reqiured. 3Cx4sq.mm Al Cable

4

-

-

... More
Supply and making end termination with brass double compression gland, earth clip and aluminum lugs/ Cu lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminum conductor cable of 1.1kV Grade as reqiured. 2Cx2.5 sq.mm Cu Control Cable

4

-

-

... More
Supply and making end termination with brass double compression gland, earth clip and aluminum lugs/ Cu lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminum conductor cable of 1.1kV Grade as reqiured. 12Cx2.5 sq.mm Cu Control Cable

4

-

-

... More
Supply of reccessed/ surface mounted LED luminaire with higher effiiciency with a nominal system lumen output of 3600 lumens and a minimum system efficency 100 lm/W full diffuser providing uniform light. The luminaire should have a color temperature of 3000/5700K and CRI80.The luminaire shall meet IP20 rating with THD10% and PF 0.9.The luminaire housing should made of plastic with a polycarbonate reflector and a high quality diffuser and the lumonair should be griha certified. The total power consumption should not exceed 7W (including driver)MODEL - G-20-25-6K-N-RC-SQ GM or eq

215

-

-

... More
Supply of sleek and seamless profiled extruded aluminium/polycarbonate batten with an efficient diffuser to illuminate work and retail spaces.luminaire with a nominal system lumen output of 2000 lumens and a minimum system efficacy 100 lm/W full diffuser providing uniform light. The luminaire should have a color temperature of 5700K and CRI80.The lumonair should be griha certified.The total power consumption should not exceed 20W (including driver).MODEL - GM10015 or eq

120

-

-

... More
Supply of reccessed/ surface mounted LED luminaire with high performance and efficiency.luminaire with a nominal system lumen output of 1500 lumens and a minimum system efficacy 100 lm/W full diffuser providing uniform light. The luminaire should have a color temperature of 5700K and CRI80.The lumonair should be griha certified. The total power consumption should not exceed 15W (including driver) model - GM o242 or eq

15

-

-

... More
Supply of reccessed/ surface mounted LED luminaire Mollis range with high performance and efficiency .luminaire with a nominal system lumen output of 600 lumens and a minimum system efficacy 100 lm/W full diffuser providing uniform light. The luminaire should have a color temperature of 5700K and CRI80.The lumonair should be griha certified. The total power consumption should not exceed 6W (including driver) MODEL - GM 0246

22

-

-

... More
Supply and installation of step light 1/2/3W, 12V LED fittings including drive unit fixed on step walls concealed 150X90 mm

15

-

-

... More
Supply and installation of one metre LED step light 1/2/3w,12v fittings including drive unit of local make fixed on step walls Lux levels as per SMPTE standards

75

-

-

... More
Supply and installation of LED signage board including drive of EXIT-7 nos, TOILET-4 nos, No smoking-4 nos., Theatre Name 3 nos, etc. in English and Malayalam as required

36

-

-

... More
Supply and installation of seat no indication 1W, 12V LED fittings including drive unit fixed on seatside of cross aisle . (6"X6") letter size --2"

125

-

-

... More
Supply and installation of Building light luminaire 50W suitable for out door including all accessories

20

-

-

... More
Supply and installation of flood light luminaire suitable for 30W led lamp including all accessories

4

-

-

... More
Supply and installation of cove light luminaire suitable for use with 5M LED Strip including drive and all accessories of philips

75

-

-

... More
Supply and installation 1/2 W spot light (Warm White) including all accessories

50

-

-

... More
Supply and installation 1/2 W spot light (Colour) including all accessories

50

-

-

... More
Supply and installation weather proof 6W focus light (White) including all accessories

50

-

-

... More
Supply and installation 3W focus light (White) including all accessories

50

-

-

... More
Supply and installation of LED light luminaire suitable for use with 1x12W warm white LED lamp including all accessories suitable for dimmer control and lamp euivalent to D 8-40W E27 2700K of Philips.

15

-

-

... More
Supplying 5 star rated , BEE certified 26W, ceiling fan with BLDC motor, with super enamelled copper wire winding, 230 V, single phase 50 HZ remote control operated fan with 1200mm sweep and 3 blades including all accessories as required with remote and standard length downrod all accesories required for complete installation (Havells Efficienca Neo or equivalent)

18

-

-

... More
Supply of exhaust fan of 250mm sweep in the existing opening, as required, including all accessories as rquired for complete installation incluidng shutter etc complete as required.(havells, Ventil Air DX White or equivalent)

5

-

-

... More
PVC FLEXIBLE CONDUIT Supply and clamping the following size of corrugated pvc fiexible conduit with necessary locking ring and check nut at termination pointed using suitable size GI/painted MS saddles spacing not exceeding 60 cms on surface including making good the damages, colour washing etc.as required. 20mm dia

100

-

-

... More
PVC FLEXIBLE CONDUIT Supply and clamping the following size of corrugated pvc fiexible conduit with necessary locking ring and check nut at termination pointed using suitable size GI/painted MS saddles spacing not exceeding 60 cms on surface including making good the damages, colour washing etc.as required. 25mm dia

80

-

-

... More
Supplying, fixing, testing and commissioning following four pole and double pole , 415 volts and 240 volts, residual current circuit breaker with overload protection (RCBO) of the following rating and sensitivity current in the existing MCB SPN and TPN horizontal/vertical DB's complete with connections, etc. as required and instructed by engineer in charge/consultant.. 63A 100mA FP RCBO

2

-

-

... More
Supplying, fixing, testing and commissioning following four pole and double pole , 415 volts and 240 volts, residual current circuit breaker with overload protection (RCBO) of the following rating and sensitivity current in the existing MCB SPN and TPN horizontal/vertical DB's complete with connections, etc. as required and instructed by engineer in charge/consultant.. 40A 100mA FP RCBO

9

-

-

... More
Supplying, fixing, testing and commissioning following four pole and double pole , 415 volts and 240 volts, residual current circuit breaker with overload protection (RCBO) of the following rating and sensitivity current in the existing MCB SPN and TPN horizontal/vertical DB's complete with connections, etc. as required and instructed by engineer in charge/consultant.. 25A 30mA FP RCBO

11

-

-

... More
Supplying, fixing, testing and commissioning following four pole and double pole , 415 volts and 240 volts, residual current circuit breaker with overload protection (RCBO) of the following rating and sensitivity current in the existing MCB SPN and TPN horizontal/vertical DB's complete with connections, etc. as required and instructed by engineer in charge/consultant.. 16A 30mA DP RCBO

2

-

-

... More
Wiring for Staircase Light Point: Wiring for stair case light points with 2.5 sq.mm FRLS PVC insulated copper conductor single core cable in and including surface / recessed medium class PVC conduit and all acessories required for complete installation etc , with 1 way modular switch, modular plate, suitable GI box medium class PVC conduit and all acessories required etc and earthing the point with 2.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required and instructed by engineer in charge/consultant. (*Note - Staircase light point shall be controlled by a single switch located inside fire control room in ground floor as per latest fire norms). One light point controlled by one way switch

20

-

-

... More
Wiring for Staircase Light Point: Wiring for stair case light points with 2.5 sq.mm FRLS PVC insulated copper conductor single core cable in and including surface / recessed medium class PVC conduit and all acessories required for complete installation etc , with 1 way modular switch, modular plate, suitable GI box medium class PVC conduit and all acessories required etc and earthing the point with 2.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required and instructed by engineer in charge/consultant. (*Note - Staircase light point shall be controlled by a single switch located inside fire control room in ground floor as per latest fire norms). Loop wiring for light points

40

-

-

... More
PVC RECESS BOX: Supplying and fixing following size/modules, PVC flush mounted box, deep mounting box for mounting in wall trunking/furniture cut outs/ bed head panels etc for fixing modular baseplate and cover plate for modular switches etc as required as instructed by engineer in charge 3 Module

10

-

-

... More
PVC RECESS BOX: Supplying and fixing following size/modules, PVC flush mounted box, deep mounting box for mounting in wall trunking/furniture cut outs/ bed head panels etc for fixing modular baseplate and cover plate for modular switches etc as required as instructed by engineer in charge. 4 module

10

-

-

... More
PVC RECESS BOX: Supplying and fixing following size/modules, PVC flush mounted box, deep mounting box for mounting in wall trunking/furniture cut outs/ bed head panels etc for fixing modular baseplate and cover plate for modular switches etc as required as instructed by engineer in charge. 6 module

10

-

-

... More
Supplying and fixing following size/modules, PVC surface box on surface for modular switches etc as required as instructed by engineer in charge 1/2 module

10

-

-

... More
Supplying and fixing following size/modules, PVC surface box on surface for modular switches etc as required as instructed by engineer in charge 3 module

10

-

-

... More
Supplying and fixing following size/modules, PVC surface box on surface for modular switches etc as required as instructed by engineer in charge 4 module

10

-

-

... More
ISOLATOR FOR VDB: Supply, fixing, testing and commisioning of following rating and 4pole Isolator in existing Vertical distribution board with spredear links, terminal connections and all accesories as required making all necessary connections etc as required and instructed by engineer in charge/consultant. 63A FP Isolator

5

-

-

... More
TPN DISTRIBUTION BOARDS: Supplying,fixing, testing and commisioning following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, conforming to IEC 61439-3, with seperate compartment for incomer, & outgoings 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, insulated busbar & shrouded neutral bars, with provision for FP Isolator as incomer, and MCB outgoings. The DB shall have seperation between incomer & outgoings, with wire set for interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) 3 Ph 4 way DB

14

-

-

... More
TPN DISTRIBUTION BOARDS: Supplying,fixing, testing and commisioning following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, conforming to IEC 61439-3, with seperate compartment for incomer, & outgoings 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, insulated busbar & shrouded neutral bars, with provision for FP Isolator as incomer, and MCB outgoings. The DB shall have seperation between incomer & outgoings, with wire set for interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) 3 Ph 6 way DB

5

-

-

... More
MCB: Supply, installation, testing and commisioning of following rating TP C curve MCB, 10kA as per IS/IEC 60898-12002 in the existing MCB VDB including all connections and iterconnections as required and as instructed by engineer in charge/consultant. 40A TP MCB

9

-

-

... More
MCB: Supply, installation, testing and commisioning of following rating TP C curve MCB, 10kA as per IS/IEC 60898-12002 in the existing MCB VDB including all connections and iterconnections as required and as instructed by engineer in charge/consultant. 25A TP MCB

11

-

-

... More
MCB: Supply, installation, testing and commisioning of following rating TP C curve MCB, 10kA as per IS/IEC 60898-12002 in the existing MCB VDB including all connections and iterconnections as required and as instructed by engineer in charge/consultant. 16A SP MCB

2

-

-

... More
TERMINATION BOXES: Supply, installation, testing and commisioning of self extinguishing, weatherproof cabinets suitaible tfor outdoor application (IP 65, IK 09) with reversible door and cabinet with terminals for looping of cables and rail for fixing modular isolator along with DP isolator including all connections and interconnections as required for outdoor application as instructed by engineer in charge.

5

-

-

... More
TERMINATION BOXES: Supply, installation, testing and commisioning of self extinguishing, weatherproof cabinets suitaible tfor outdoor application (IP 65, IK 09) with reversible door and cabinet with terminals for looping of cables and rail for fixing modular isolator along with TP isolator including all connections and interconnections as required for outdoor application as instructed by engineer in charge.

10

-

-

... More
CABLE MANAGEMENT SYSTEM: Supply and fixing of 32 x 12.5 mm PVC Cable Management System with base and lid along with all accessories like external angle, internal angle, flat angle, end cap etc conforming to IEC 61084/ BS 476 & 4678 on surface as required and instructed by engineer in charge/consultant, including all accesories as required for complete installation. 32 x 12.5mm CMS

50

-

-

... More
Dismantling and resiting carefully with out damage the existing Transformer including removing cable terminations and earthing, etc.. Complete storing at a place 15 mtrs away Dismantling and resiting carefully with out damage the exisitng DG set including removing cable terminations and earthing, smoke pipe, etc.. Complete. Removal of DB including Removal of isolator/mcb and / Removing of switch board Removal of existing seat lights by disconnecting wires etc Dismantling and removing unwanted cables of various sizes from trench, without damaging the existing cables and keeping it in a place of storage.

1

-

-

... More
Supply and fixing RJ 11 telephone socket in MS box and giving connection etc. complete.

8

-

-

... More
Supply and fixing T.V co-axial socket outlet fixed on metal concealed box made of 16SWG CR sheet with all necessary accessories such as face plate, shutter etc., complete as required.

3

-

-

... More
Supply and installation of Twin Data socket out let of RJ 45 Cat 6. The MS box shall have suitable arrangement for fixing/grouting in workstation/table/wall/partition as required at site.

10

-

-

... More
Supply and installation of Single Data socket out let of RJ 45 Cat 6. The MS box shall have suitable arrangement for fixing/grouting in workstation/table/wall/partition as required at site.

10

-

-

... More
Supply and wiring cat 6 cable through 20 mm ISI marked PVC conduit

250

-

-

... More
Supply and wiring pvc sheathed unarmoured 0.51 gauge tinned copper conductor 2 pair telephone cable as required through 20 mm ISI marked PVC conduit

100

-

-

... More
Synthetic insulating mats conforming to IS: 15652:2006 use to 3.3 - 11kV voltage - 2.5 mm Thick, 2Mtr Length 1 Mtr Width

3

-

-

... More
Synthetic insulating mats conforming to IS: 15652:2006 use to 3.3 - 11kV voltage - 2 mm Thick, 2Mtr Length 1 Mtr Width

6

-

-

... More
DCP type 5Kg fire extinguisher or equivalent.

2

-

-

... More
Co2 type 6.5 kg fire extinguishers

6

-

-

... More
Caution board (HT & LT )

5

-

-

... More
Shock treatment chart Electrical Inspectorate scope

1

-

-

... More
Rubber gloves (11KV) 1 pair

2

-

-

... More
4 fire bucket with single stand for 4 buckets & sand to fill the buckets

2

-

-

... More
Discharge rod

1

-

-

... More
First aid box with all items

1

-

-

... More
5 kVA UPS : Supply, installation, and commissioning of 5kva UPS stand-alone Configuration. Single phase in and out. with inbuilt isolation transformer (IP20), Input pf 0.99, it shall be 100% generator compatible, with Efficiency 83 % and output power factor unity (5kVA = 5kW), including all accessories etc as required. The acoustic noise at 1m of the system should be55dB.The system shall comply to IEC /EN 62040-1,2,3 and relevant IS standard along. The system shall be true online double - conversion DSP based UPS system and also UPS shall be with automatic & manual bypass switch. The system shall have IGBT rectifier and inverter. warranty 2 years ups and 2 years batteries. including rack and inter connecting cables. 5 kva Load Minimum VAH 6240 per UPS for 15 min backup SMF battery of reputed approved make exide/quanta Battery Price for the above configuration 12v 26Ah 20 nos

4

-

-

... More
20 kVA UPS : Supply, installation, commissioning and AMC of 20 kVA UPS from the manufacturer directly including battery and transformer of three phase in and out with PRS configuration. with indoor (IP20) with surge protection system Input pf 0.99, Input THDi 5%, inbuilt isolation transformers at input side even in the bypass mode, with necessary battery circuit breaker, double conversion technology with input 400V, 50Hz three phase, output 400V, 50Hz three phase, It shall be 100% generator compatible, with Efficiency 92 % and output power factor .9 (20KVA=18kW), Eco mode Efficiency 98% and including all accessories etc as required. The acoustic noise at 1m of the system should be75dB.The system shall comply to EN/IEC 62040-3 and relevant IS standard. The system shall be true online double - conversion DSP based UPS system and also UPS shall be with automatic & manual bypass switch. The system shall have IGBT rectifier and inverter. Including rack and inter connecting cables. Battery for the above configuration 12v 34Ahx 20 nos

2

-

-

... More
Supply and fixing of 8 mm Aluminum Round Conductor as horizontal air terminal for parapet wall/terrace/metal roof with 0.5 mm thickness with the required mounting clamps , cross connectors , expansion piece,roof conductor holder, base and other accessories required as per IEC 62305-3

190

-

-

... More
Supply and fixing of 8 mm Aluminum Round Conductor as down conductor with the required mounting clamps , cross connectors , expansion piece , roof holders , holding base and other accessories required as per IEC 62305-3 The horizontal conductors above the roof shall be fixed by using drill free mechanism by using suitable clamps rigidly. Drilling above the roof should not allowed and the fixing clamps should be desined in such a way that the connection should be strong.

180

-

-

... More
Providing and fixing of test joint suitable for hot dipped galvanized steel tape 32 mm x 6mm and 8mm dia solid round aluminium conductor made of stainless steel SS 304 grade . Conforms to the requirements according to (IS/IEC 62305).with an outdoor glass-fibre reinforced polycarbonate enclosure having minimum inner dimension of 75mm x 75 mm x 50 mm.

12

-

-

... More
Providing and laying hot dipped galvanized steel tape 32 mm X6 mm (IS 4759: 1996) from earth electrode directly in ground as required. Flat conductor shall be of hot dipped and cross sectional area of 90 sqmm and cross connectors must be provided at crossings. Zinc coating: 610g/m square and should be tested and used for lightning protection earth system and equipotential bonding.

250

-

-

... More
Earthing with G.I. earth pipe 2.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.

12

-

-

... More
Supply and laying the following sizes of strips on cable tray/wall surface, including necessary clamps (each clamp not exceeding 60 cm) and bolts etc as required for complete installation as instructed by engineer in charge/consultant. 25x3mm Cu strips tinned at the point of contact

75

-

-

... More
Supply and laying the following sizes of strips on cable tray/wall surface, including necessary clamps (each clamp not exceeding 60 cm) and bolts etc as required for complete installation as instructed by engineer in charge/consultant. Copper wire No.10 SWG

125

-

-

... More
Supply and laying the following sizes of strips on cable tray/wall surface, including necessary clamps (each clamp not exceeding 60 cm) and bolts etc as required for complete installation as instructed by engineer in charge/consultant. Copper wire No.8 SWG

100

-

-

... More
Supply and laying the following sizes of Cu strips laid 0.6 m below ground level including excavating trench of suitable size and refilling ,including necessary clamps and bolts etc and all accessories as required for complete installation as instructed by engineer in charge/consultant. 25x3mm Cu strips tinned at the point of contact

150

-

-

... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.

10

-

-

... More
Supplying and laying 25 mm X 6 mm copper strip at 0.50 meter below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50 mm)

75

-

-

... More
Providing and fixing 25 mm X 6 mm copper strip on surface or in recess for connections etc. Provide porcelain insulator at 50 cm spacing with all accessories as required.

20

-

-

... More
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.with charcoal/ coke and salt as required.

6

-

-

... More
90 kVAr APFC PANEL: Supply,erection, testing and commissioning of 14 SWG freestanding indoor cubicle made of CRCA sheet steel with seven tank process. Automatic power factor control panel of rating 90kVAr  with 7% Block Reactor & tuned capacitors using capacitor swtiching. By using Microprocessor based relay operated controller with minimum 8 stage which should be capable to switch on the required kVAr for compensation based on cyclic switching. 200A  25kA 3P MCCB with  high rupturing capacity and in built overload and short circuit releases as per specifications  as incomer, , housing capacitors with heavy duty polypropylene as a dielectric with vaccum deposited conductors on the polypropylene as electrodes in 6steps of 25KVAR X 2, 15KVAR X 1X,10kVARX2, 5kVARX1) and capacitor as required (10/5) shall be directly connected to the main bus for no load compensation. The capacitors shall be with U.L listed pressure sesitive interrupter, inside hermctically sealed metal cans. with terminal bushings to withstand 10 KV AC to ground with treated terminals and capacitor cells shall be provided with discharge resistors to reduce residual voltage 50Vwithin one min of de-energisation.. All controls shall be mounted on enclosure door with door interlocks. Heavy duty capacitor duty contactors with high rupturing MCB shall be used for individual stage control.  Metering : Digital Ammeter with  CT -3Nos , Digital Voltmeter with selector- 1No ,  R Y B Indication with control fuse -1Set, Automanual selector switch- 1No , Forced cooling using fans, APFC relay - 1 no. including all connections and interconnections, all accesories as required for complete installation as instructed by engineer in charge/consultant. 

1

-

-

... More
MSB: Supply,Installation, testing & commissioning of cubicle type, dust and vermin proof, floor mounted, front operated MV panel board made out of 16 SWG thick CRCA sheet, fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel etc including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable as per general specifications and drawings complete with all interconnections, powder coating , control wiring etc… as per IS,KSEB / Inspectorate Regulations and General conditions/ Technical Specifications. Panel shall be quoted with all interconnection and internal wiring and cabling as shown in the schematic. The panel shall be of for 4A category meeting all requirements as per the standard.This panel should include Bus bar mounting (4+0) Surge Protection Device Class B & Class C/ Type 1 & Class 2 Tested as per IEC 61643 Part 11:2016 & UL 1449 4th edition. Total Impulse current-50 KA (10/350µ sec) & Total Max Discharge current 560KA (8/20µ sec), Voltage protection level 1.3 kV . The Surge Protection Devices should have TOV withstand for 120 Min : 528 V and with out Follow Current & Leakage Current. Protective Elements are a single, heavy duty, distribution grade Metal Oxide Varistor (MOV) disk, assembled under pressure in an environmentally sealed aluminum casing. & the Protection Modes for : L & N to PE .Short- Circuit Current rating (Isccr) – 85 kA/50 Hz . With in built Back up fuse upto 1600A. Total Response time 1 nano sec . Warranty: 10 years and 20 years life time cycle tested.Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant.Incomer -EB Incomer - 630A, 36kA Microprocessor based FP MCCB, fixed type with 3 O/C & 1 E/F releases, stand by low set E/F relay with CT at neutral earthing strip - 1 no.DG Incomer - 500A 36kA Microprocessor based FP MCCB fixed type , 3 O/C and 1 E/F release and stand by low set earth fault relay using CT neutral earthing conductor -1 no.ATS - 630A 4 Pole with AMF controller in open frame (without enclosure) The switch shall have three possible operating positions (source one - center off –source two). The two sources can be isolated in the center off position. A position locking mechanism should also be provided. Phase loss sensing need to be provided .- 1 no 630A 433V, 36kA best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement as shown in schematicMulti function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, kWh, KW, frequency, KVA, kVAr, PF, kVAh, kVArh, Runhours, On hours, Interupts, RPM,Events(High-Low),Neutral current. Phase angle, - 1 setRYB phase indicating LED lamps with control fuses and switches - 2 set.Bus bar mounting Surge Protection Device Class B & Class C/ Type 1 & Class 2 - 1 setAPFC relay module of 9 stages with 415V with necessary CT and accessories- 1 nosReverse current protection relay for gensets wit CT 630A/5A CL.1,15VAOutgoings320A 25kA FP MCCB Microprocessor based - 1 nos.250A 25kA FP MCCB Microprocessor based - 1 nos.200A 25kA FP MCCB Microprocessor based - 1 nos.125A 36kA FP MCCB Microprocessor based - 5 nos.400 A FP Isolator - 1 no

1

-

-

... More
SUB PANEL : Supply,Installation, testing & commissioning of cubicle type, dust and vermin proof, floor mounted, front operated MV panel board made out of 16 SWG thick CRCA sheet, fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel etc including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable as per general specifications and drawings complete with all interconnections, powder coating , control wiring etc… as per IS,KSEB / Inspectorate Regulations and General conditions/ Technical Specifications. Panel shall be quoted with all interconnection and internal wiring and cabling as shown in the schematicIncomer - 125A TPN ISO 1 nos.125, 433V, 36 kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. RYB phase indicating LED lamps with control fuses and switches - 1 set.Bus bar mounting Surge Protection Device Class B & Class C/ Type 1 & Class 2 - 1 setMulti function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, kWh, KW, frequency, KVA, kVAr, PF, kVAh, kVArh, Runhours, On hours, Interupts, RPM,Events(High-Low),Neutral current. Phase angle, - 1 setOutgoings63A TP MCB - 5 no.

1

-

-

... More
GROUND FLOOR PANEL : Supply,Installation, testing & commissioning of cubicle type, dust and vermin proof, floor mounted, front operated MV panel board made out of 16 SWG thick CRCA sheet, fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel etc including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable as per general specifications and drawings complete with all interconnections, powder coating , control wiring etc… as per IS,KSEB / Inspectorate Regulations and General conditions/ Technical Specifications. Panel shall be quoted with all interconnection and internal wiring and cabling as shown in the schematicIncomer - 125A TPN ISO 1 nos.125A, 433V, 25 kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. RYB phase indicating LED lamps with control fuses and switches - 1 set.Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, kWh, KW, frequency, KVA, kVAr, PF, kVAh, kVArh, Runhours, On hours, Interupts, RPM,Events(High-Low),Neutral current. Phase angle, - 1 setOutgoings63A TP MCB - 4 no.

1

-

-

... More
FOURTH FLOOR PANEL: Supply, installation, testing & commissioning of cubicle type, dust and vermin proof, floor mounted, front operated MV panel board made out of 16 SWG thick CRCA sheet, fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel etc including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable as per general specifications and drawings complete with all interconnections, powder coating , control wiring etc… as per IS,KSEB / Inspectorate Regulations and General conditions/ Technical Specifications. Panel shall be quoted with all interconnection and internal wiring and cabling as shown in the schematicIncomer - 125A TPN ISO 1 nos.125A, 433V, 36 kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. RYB phase indicating LED lamps with control fuses and switches - 1 set.Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, kWh, KW, frequency, KVA, kVAr, PF, kVAh, kVArh, Runhours, On hours, Interupts, RPM,Events(High-Low),Neutral current. Phase angle, - 1 setOutgoings 63A TP MCB - 1 no.,40A TP MCB - 2 no.,25A DP MCB - 3 no.

1

-

-

... More
UTILITY PANEL: Supply, installation, testing & commissioning of cubicle type, dust and vermin proof, floor mounted, front operated MV panel board made out of 16 SWG thick CRCA sheet, fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel etc including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable as per general specifications and drawings complete with all interconnections, powder coating , control wiring etc… as per IS,KSEB / Inspectorate Regulations and General conditions/ Technical Specifications. Panel shall be quoted with all interconnection and internal wiring and cabling as shown in the schematic.Incomer - 125A TPN ISO 1 nos.125A, 433V, 25 kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. RYB phase indicating LED lamps with control fuses and switches - 1 set.Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, kWh, KW, frequency, KVA, kVAr, PF, kVAh, kVArh, Runhours, On hours, Interupts, RPM,Events(High-Low),Neutral current. Phase angle, - 1 set.Outgoings 63A TP MCB - 4 no.,40A TP MCB - 1 no.,25A DP MCB - 3 no.

1

-

-

... More
HVAC PANEL KAIRALI: Supply, installation, testing & commissioning of cubicle type, dust and vermin proof, floor mounted, front operated MV panel board made out of 16 SWG thick CRCA sheet, fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel etc including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable as per general specifications and drawings complete with all interconnections, powder coating , control wiring etc… as per IS,KSEB / Inspectorate Regulations and General conditions/ Technical Specifications. Panel shall be quoted with all interconnection and internal wiring and cabling as shown in the schematic.Incomer - 320A TPN ISO -1 no 320A, 433V, 16 kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Surge Protection Device Class B+C/ Type 1+2 - 1 set.RYB phase indicating LED lamps with control fuses and switches - 1 set.Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, kWh, KW, frequency, KVA, kVAr, PF, kVAh, kVArh, Runhours, On hours, Interupts, RPM,Events(High-Low),Neutral current. Phase angle, - 1 set.Outgoings 120 A TP MCCB - 2 nos,100A TP MCCB - 2 nos.

1

-

-

... More
HVAC PANEL SREE: Supply, installation, testing & commissioning of cubicle type, dust and vermin proof, floor mounted, front operated MV panel board made out of 16 SWG thick CRCA sheet, fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel etc including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable as per general specifications and drawings complete with all interconnections, powder coating , control wiring etc… as per IS,KSEB / Inspectorate Regulations and General conditions/ Technical Specifications. Panel shall be quoted with all interconnection and internal wiring and cabling as shown in the schematic.Incomer - 250A TPN ISO -1 no 250A, 433V, 16 kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Surge Protection Device Class B+C/ Type 1+2 - 1 set RYB phase indicating LED lamps with control fuses and switches - 1 set.Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, kWh, KW, frequency, KVA, kVAr, PF, kVAh, kVArh, Runhours, On hours, Interupts, RPM,Events(High-Low),Neutral current. Phase angle, - 1 set.Outgoings 100A TP MCCB - 4nos.,63A TP MCB - 2 no.

1

-

-

... More
PUMP PANEL: Supply, installation, testing & commissioning of cubicle type, dust and vermin proof, floor mounted, front operated MV panel board made out of 16 SWG thick CRCA sheet, fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel etc including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable as per general specifications and drawings complete with all interconnections, powder coating , control wiring etc… as per IS,KSEB / Inspectorate Regulations and General conditions/ Technical Specifications. Panel shall be quoted with all interconnection and internal wiring and cabling as shown in the schematic Incomer - 63A TPN ISO -1 no,63A, 433V, 25 kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. RYB phase indicating LED lamps with control fuses and switches - 1 set.Surge Protection Device Class B+C/ Type 1+2 - 1 set.Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, kWh, KW, frequency, KVA, kVAr, PF, kVAh, kVArh, Runhours, On hours, Interupts, RPM,Events(High-Low),Neutral current. Phase angle, - 2 set.Outgoings 25A TP MCB - 2 nos.,25A Change over switch- 2 set,DOL starters - for 5HP motor

1

-

-

... More
MSB 1: Supply,Installation, testing & commissioning of cubicle type, dust and vermin proof, floor mounted, front operated MV panel board made out of 16 SWG thick CRCA sheet, fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel etc including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable as per general specifications and drawings complete with all interconnections, powder coating , control wiring etc… as per IS,KSEB / Inspectorate Regulations and General conditions/ Technical Specifications. Panel shall be quoted with all interconnection and internal wiring and cabling as shown in the schematic. The panel shall be of for 4A category meeting all requirements as per the standard.This panel should include Bus bar mounting (4+0) Surge Protection Device Class B & Class C/ Type 1 & Class 2 Tested as per IEC 61643 Part 11:2016 & UL 1449 4th edition. Total Impulse current-50 KA (10/350µ sec) & Total Max Discharge current 560KA (8/20µ sec), Voltage protection level 1.3 kV . The Surge Protection Devices should have TOV withstand for 120 Min : 528 V and with out Follow Current & Leakage Current. Protective Elements are a single, heavy duty, distribution grade Metal Oxide Varistor (MOV) disk, assembled under pressure in an environmentally sealed aluminum casing. & the Protection Modes for : L & N to PE .Short- Circuit Current rating (Isccr) – 85 kA/50 Hz . With in built Back up fuse upto 1600A. Total Response time 1 nano sec . Warranty: 10 years and 20 years life time cycle tested.Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant.Incomer -EB Incomer - 320A, 25kA Microprocessor based FP MCCB, draw out type with 3 O/C & 1 E/F releases, stand by low set E/F relay with CT at neutral earthing strip - 1 no.320A 433V, 36kA best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement as shown in schematic.Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, kWh, KW, frequency, KVA, kVAr, PF, kVAh, kVArh, Runhours, On hours, Interupts, RPM,Events(High-Low),Neutral current. Phase angle, - 1 set.RYB phase indicating LED lamps with control fuses and switches - 2 set.Bus bar mounting Surge Protection Device Class B & Class C/ Type 1 & Class 2 - 1 set.Outgoings 63A TP MCB - 4 no.

1

-

-

... More
METERING PANEL 1,2 Supply erection, testing and commissioning of dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided.Incomers -63A TPN Isolator - 1 no.63A, best conductivity Aluminium TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. RYB phase indicating LED lamps with control fuses and switches - 1 set.OutgoingConsumer service each unit consisting of 1No. 32A DP MCB, 32 A fuse unit Providing 32A one number single phase direct base mounting type 10A - 32A for the existing sleek body energy meter and the meter shall be shifted from existing panel to new panel by contractor and aproval shall be taken from KSEBL including all accessories required for complete installation and its inter connections etc only cubicle is considered - 12 nos

2

-

-

... More
METERING PANEL 3: Supply erection, testing and commissioning of dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided. Incomers -63A TPN Isolator - 1 no.63A, best conductivity Aluminium TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. RYB phase indicating LED lamps with control fuses and switches - 1 set.Outgoing A) Consumer service each unit consisting of 1No. 40A TP MCB, 40 A fuse unit,and one number 3 phase 4 wire direct base mounting type 10A - 40A for the existing sleek body energy meter and the meter shall be shifted from existing panel to new panel by contractor and aproval shall be taken from KSEBL including all accessories required for complete installation and its inter connections etc only cubicle is considered Set - 4 nos B) Consumer service each unit consisting of 1No. 32A DP MCB, 32 A fuse unit Providing 32A one number single phase direct base mounting type 10A - 32A for the existing sleek body energy meter and the meter shall be shifted from existing panel to new panel by contractor and aproval shall be taken from KSEBL including all accessories required for complete installation and its inter connections etc only cubicle is considered - 4 nos

1

-

-

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.

543

-

-

... More
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.

800

-

-

... More
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.

10

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 x 1.5 sq.mm + 1 x1.5 sq.mm earth wire

4500

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire

3000

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 x 4 sq.mm +1 x 4 sq.mm earth wire

250

-

-

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm

250

-

-

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm

150

-

-

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 32mm

100

-

-

... More
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

50

-

-

... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mm x 75mm)

80

-

-

... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 3 Module (100mm x 75mm)

75

-

-

... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 4 Module (125mm x 75mm)

50

-

-

... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 6 Module (200mm x 75mm)

30

-

-

... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 8 Module (200mm x 75mm)

25

-

-

... More
Supplying and fixing following Modular base and cover plate on existing modular metal boxes/PVC boxes/furniture cut outs/CMS etc as required 1 or 2 Module

80

-

-

... More
Supplying and fixing following Modular base and cover plate on existing modular metal boxes/PVC boxes/furniture cut outs/CMS etc as required 3 Module

75

-

-

... More
Supplying and fixing following Modular base and cover plate on existing modular metal boxes/PVC boxes/furniture cut outs/CMS etc as required 4 Module

50

-

-

... More
Supplying and fixing following Modular base and cover plate on existing modular metal boxes/PVC boxes/furniture cut outs/CMS etc as required 6 Module

30

-

-

... More
Supplying and fixing following Modular base and cover plate on existing modular metal boxes/PVC boxes/furniture cut outs/CMS etc as required 8 Module

25

-

-

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch

170

-

-

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 A switch

30

-

-

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 A socket outlet

164

-

-

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 A socket outlet

30

-

-

... More
Supplying and fixing suitable size GI box for surface application with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.

15

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.

10

-

-

... More
Supply and fixing 3 pin, 6A ceiling rose on the existing junction box / wooden block including connection etc as required.

25

-

-

... More
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.

18

-

-

... More
Installation of exhaust fan upto 450mm in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.

15

-

-

... More
Supplying and fixing brass batten/ angle holder including connections etc. as required.

20

-

-

... More
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB,“C” curve including connections, painting etc. as required.

5

-

-

... More
Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)

18

-

-

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way double door

9

-

-

... More
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12), Double door

8

-

-

... More
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole

350

-

-

... More
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

25

-

-

... More
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

25

-

-

... More
Supplying and fixing Cable End Box (Loose wire box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.

25

-

-

... More
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

5

-

-

... More
Supplying and fixing 20 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

5

-

-

... More
Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

5

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the exisitng RCC/Hume/Metal pipe as required. Above 185 sq. mm and upto 400 sq. mm

50

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing masonry open duct as required. Above 35 sq. mm and upto 95 sq. mm

200

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing masonry open duct as required. Above 185 sq. mm and upto 400 sq. mm

120

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle)

600

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required. Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

100

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required. Above 95 sq. mm and upto 185 sq. mm (clamped with 25/ 40x3mm MS flat clamp)

30

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required. Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)

25

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on cable tray as required. Upto 35 sq. mm (clamped with 25/ 40x3mm MS flat clamp)

300

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on cable tray as required. Above 95 sq. mm and upto 185 sq. mm (clamped with 25/ 40x3mm MS flat clamp)

125

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on cable tray as required. Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)

25

-

-

... More
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.l. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.

50

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.Upto 35 sq. mm

20

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 kV grade of following size in the existing masonry open duct as required. Above 120 sq. mm and upto 400 sq. mm

45

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 kV grade of following size in the existing RCC/HUME/ METAL pipe as required. Above 120 sq. mm and upto 400 sq. mm

15

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 3.5c X 400 sq. mm

8

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 3.5c X 240 sq.mm

4

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 3.5c X 185 sq. mm

6

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 3.5c X 120 sq. mm

2

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 3.5c X 70 sq. mm

4

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 3.5c X 50 sq.mm

2

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 3.5c X 35 sq. mm

4

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 4c X 25 sq. mm

30

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 4c X 16 sq mm

16

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 4c X 10 sq mm

2

-

-

... More
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 kV grade as required. 300 sq. mm

7

-

-

... More
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 kV grade as required. 300 sq. mm

1

-

-

... More
MS perforated cable tray Hot Dipped Galvanized 100 X 50 X 1.6 mm

100

-

-

... More
MS perforated cable tray Hot Dipped Galvanized 150 X 50 X 1.6 mm

100

-

-

... More
MS perforated cable tray Hot Dipped Galvanized 225 X 50 X 1.6 mm

75

-

-

... More
MS perforated cable tray Hot Dipped Galvanized 300 X 50 X 1.6 mm

100

-

-

... More
Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade : 13.102.1 One or more coats on old work after removing old paint completely and sanding.

100

-

-

... More
Supply and installing of DG exhaust support etc using structural steel work (riveted, bolted or welded) in built up sections, including angle, channel, I section, necessary nut and bolt and all required accessories including cutting, hoisting, fixing in position and applying 2 coats of primer and 2 coats of enamel paint of approved quality etc as required.

500

-

-

... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 200 mm dia (OD-63 mm & ID-51 mm nominal)

40

-

-

... More
Providing and fixing M.S. Fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required.

25

-

-

... More
Providing and fixing circular/ Hexagonal GI box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick GI sheet with its top surface hacked for proper bonding, top lid shall be screwed into the GI box by means of 3.3 mm dia round headed screws, one lock at the corners, clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.

25

-

-

... More
75 mm thick back filling for pitching including supplying of required materials and consolidation etc. complete with :Stone aggregate 20 mm nominal size

1

-

-

... More
Making hole for installation of exhaust fan of size upto 450 mm sweep by demolishing brick work manually/by mechanical means including disposal of malba within 50 meter lead and making good the wall by plastering etc. as required

1.9

-

-

... More
Providing, fixing, testing and commissioning of LED Signage for Front Arch using 3 module sunsign led and 12V 400Wats power supply for led letters and 5V75AMZ for neon strip and 2.5inch projected 2mm acrylic pt(A grade) for letter white colour(040) side beading black acrylic , base female portions are 4mm foam sheet letter and logo size as per drawing , side Malayalam letters and line area neon strip (6mm and 12mm projection) bottom letters are in the box , logo projected box type acrylic with led , side box and letters are 2mm acrylic laser cutted letters, neon line strip colour white and neon Malayalam letter colour magenta 18mm multywood base for neon line and letter etc complete

1

-

-

... More
Providing, fixing, testing and commissioning of 15x8 feet LED Signage (28inch height English letter 1 inch acrylic or neon strip, 11 inch (KA) Malayalam neon letter and 15 inch logo) for theatre facade using 3 module sunsign led with power supply and 2.5inch projected 2mm acrylic pt(A grade) for letter as per design , including cost of GI frame work using 1.5 inch 18 gage one coat epoxy primer and two coat enamel paint ,and scaffolding ect complete

1

-

-

... More
Supply, fixing, testing and commissioning of hanging 45x15 cm LED box light boards 1.5inch projected acrylic light board hanging and spacer fixing , 3mm acrylic box with 3mm texture sticker pasted and IP68 grade LED including cost of material labour and scaffolding ect complete.

11

-

-

... More
Supply, fixing, testing and commissioning of 90x45 cm hanging LED box light boards 1.5inch projected acrylic light board hanging and spacer fixing , 3mm acrylic box with 3mm texture sticker pasted and IP68 grade LED including cost of material labour and scaffolding etc complete.

4

-

-

... More
Supply, fixing, testing and commissioning of 120x60cm hanging LED box light boards 1.5inch projected acrylic light board hanging and spacer fixing , 3mm acrylic box with 3mm texture sticker pasted and IP68 grade LED including cost of material labour and scaffolding ect complete.

1

-

-

... More
Supply, fixing, testing and commissioning of 3 inch projected white solid letters with IP68 grade LED light with power supply, back reverse lighting warm Led light and front face 3mm white acrylic( 6x2.5 feet)including cost of material labour and scaffolding ect complete for ticket counter

1

-

-

... More
Supply, fixing, testing and commissioning of neon lettering and 5mm base clear acryilic with power supply for ticket counter including cost of material labour and scaffolding ect complete

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.