Kerala State Electricity Board Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 71,600Document Cost
₹ 5,900Tender Fee
Refer Documents
Summary
Constructing Ht/lt Line Using Ht Covered Conductor From Adikkadu To Valiyath Crusher And Vilanthara
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_KSEB_581751_1Bid Award Id
ViewTender No
eT03/ESD/SKTA/23-24/14.06.2023Tender Authority
Kerala State Electricity Board ViewPurchaser Address
-Website
http://etenders.kerala.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Insulater tie for covered conductor
249
72210
290
Disc Insulator 11 Kv Composite polymeric-covered conductor
75
64500
860
Hard ware Fittings-GI-for HT Covered Conductor 120sq.mm
75
40500
540
Midspan joint set for covered conductor HT
6
24000
4000
Single core outdoor termination kit for covered conductor
16
36800
2300
Insulation piercing connector set for covered conductor HT
14
63000
4500
Lightening arrestor 9 kv ,10kA( DistributionClasses)Composite polymer housing
6
14882
2480.46
GI-Wire 4mm 8swg
15
960
64
Bolt & Nut GI M 16x 40(1.5” x5/8”)
0.5
57
115
LABOUR
-
-
-
Loading HT Atype pole from the stacking place and unloading the same at work site ( Transport by vehicle )
13
7839
603
Transporting Pole by hired vehicle to a distance up to 5 km and carring up to 4 poles Excluding loading and un loading
23
32857
1428.57
Fitting and erecting 1 HT PSC pole in position including fitting cross arm ,Digging and back filling pit,Drawing earth leads
62
135036
2178
Fitting and erecting A type pole in position including fitting cross arm ,Digging and back filling pit,Drawing earth leads
13
35828
2756
Fitting and erecting HT DP using PSC poles including fitting two channel cross arm ,Digging and back filling pit drawing earth leads
5
29050
5810
Fitting and providing 1 HT Stay for PSC Pole including Digging and back filling pit
82
74948
914
Additional rate for excavation of one pit for HT pole/HT Stay in hard laterite
72
41616
578
Additional rate for excavation of one pit forA type pole in hard laterite
13
11271
867
Providing one Earth using earth pipe incl. Digging separate pit at standard distance away from the pole/structure & backfilling.
12
18096
1508
Providing one coil Earth using GI Wire incl. Digging separate pit at standard distance away from the pole/structure & backfilling.
75
54225
723
Fitting One Set of AB Switch and giving connections
5
9295
1859
Fitting One addition V-Cross arm in existing single poles including conveyance of materials
62
19840
320
Fitting One One addition75x40 mm ,1.8 channel cross arm in existing single poles including conveyance of materials
92
29440
320
Fitting One One addition 100x50x60 mm ,2.4 channel cross arm in existing 11 KV DP including conveyance of materials
10
3760
376
Dismantling without damage one HT PSC/RCC Poles after disconnecting stays, struts and stacking the same
82
104960
1280
Transferring LT Single phase 2/3 wire OH Line to newely erected HT/LT Poles and refitting all items to the new poles
35
20475
585
Transferring LT Three phase 4/5 wire OH Line to newely erected HT/LT Poles and refitting all items to the new poles
98
115934
1183
Dismantling and reconnecting Single phase servise connections from OH Line including lowering down the WP Portion
185
11840
64
Dismantling and reconnecting Three phase servise connections from OH Line including lowering down the WP Portion
16
1584
99
Dismantling one ordinary street light /CFL/LED Fitting from [pole repairing and refitting in the same in position and giving connections
64
20032
313
Cutting tree beyond 30 cm but up to including 60cm girth,cutting of trunks and branches , removing the root completely and stacking
68
21896
322
Cutting tree beyond 60 cm but up to including 120 cm girth,cutting of trunks and branches , removing the root completely and stacking
28
15204
543
Loading HT PSC pole from the stacking place and unloading the same at work site ( Transport by vehicle )
78
39546
507
Fitting and providing HT Fly stay for 11 kv pole using HT PSC Pole including digging and back filling pit
3
9591
3197
Fitting and providing HT Strut using HT PSC pole incuding digging and back filling pit
3
6099
2033
Stringing 1 KM Three phase 11 kv Line with XLPE Insulated ACSR Raccoon
2900
126121
43.49
Additional rae for providing one Disc set on any type of HT Pole for making cut point
75
7875
105
Fitting one set ( 3 nos) of 11KV LA and giving connections excluding earthing
6
1920
320
Installation of Insulation piercing connector for main to service line main :16-95sqmm, Tap : 16-95 sqmm
6
331
55.27
Doing straight joint on cables of sizes up to and including 3x 185 sq.mm using the cable joining kit supplied departmently as per specification
6
12540
2090
Doing one cable end termination on cable of sizes up to and including 3x185 sq.mm using the cable joining kit supplied departmently
16
19568
1223
Dismantling without damage One KM 11 KV Line ( 3 conductors) ,cross arms,insulators disc rolling the conductors and stacking
0.3
2759
9198
Installation of Insulation piercing connector for main to service line main :25-95 sqmm, Tap 25-95 sqmm
36
1989
55.27
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements