Kerala State Electricity Board Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 22,230Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_KSEB_273574_1Bid Award Id
ViewTender No
1/18-19/ESD/WKY/08.03.2019Tender Authority
Kerala State Electricity Board ViewPurchaser Address
-Website
http://http://www.kseb.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Transporting Transformers by hired vehicle upto 5km and upto 2 No. of 63 to 250kVA Transformers / RMUs excluding loading & unloading.
2
-
1428.57
Dismantling (without damage) one 11kV PSC/RCC pole after disconnecting stays, strut etc. and stacking the same.
2
-
2081
Dismantling (without damage) one km 11kV line (3 conductors), cross arm, insulators, disc, rolling the conductor and stacking.
0.2
-
9198
Dismantling (without damage) one HT stay incl. back filling, and bringing back to section store.
3
-
601
Dismantling one V cross arm/Channel cross arm from existing Pole, and bringing back to section store.
13
-
128
Dismantling one Channel cross arm from existing DP
structure, and bringing back to section store.
33
-
188
Dismantling (without damage) one AB switch from existing structure and bringing back to section store.
3
-
1115
Dismantling one HT pin insulator with pin and bring back to section store.
9
-
128
Additional rate for refitting/redoing one Disc set while renewing any type of 11kV cut pole
24
-
480
Renewing one 11kV Jumper using Copper/ACSR conductor as per standard specification (in loop formation for tapping from line).
15
-
288
Renewing one 11kV Jumper connection using
Copper/ACSR conductor as per standard specification.
6
-
201
Fitting and erecting one HT PSC Pole in position incl. fitting cross arm, digging & back filling pit, drawing earth leads.
3
-
2178
Fitting and erecting one HT 'A' type Pole in position incl. fitting cross arm, digging & back filling pit, drawing earth leads.
2
-
2756
Additional rate for providing one disc set on any type of
HT pole for making cut point.
30
-
105
Fitting and erecting one HT DP using PSC pole in position incl. fitting 2 channel cross arms, digging & back filling pit, drawing earth leads.
7
-
5810
Fitting and providing one HT Stay for 11kV pole incl. digging & back filling pit.
15
-
914
Fitting and providing one Strut using HT PSC pole incl. digging & back filling pit.
2
-
2033
Insertion of one HT PSC pole in existing line incl. digging & backfilling pit, fitting cross arm, insulators, binding etc.
1
-
2283
Additional rate for excavation of one Pit for HT Pole/HT Stay in Hard Laterite.
25
-
578
Additional rate for excavation of one Pit for HT Pole/HT Stay in Soft Rock.
10
-
867
Additional rate for excavation of Pit for 'A' type pole in
Soft Rock.
2
-
1301
Stringing of one km 11kV line with ACSR Raccoon (3 conductors) incl. cutting and removing tree branches wherever necessary.
0.21
-
23128
Fitting 5 channel cross arms, AB switch, DO fuse, LA, HT & LT connections on existing DP, 3 LT fuses.
2
-
7254
Erecting one 100kVA Transformer to existing DP and giving connections, incl. loading & unloading, excluding transportation.
2
-
4759
Fitting one additional Fuse unit and giving connection from Transformer to fuse and DB to LT OH line.
6
-
233
Providing one Earth using earth pipe incl. digging separate pit at standard distance away from the pole/structure & backfilling.
26
-
1508
Providing one Driven Earth using GI earth pipe at standard distance away from the pole/structure in loose soil.
8
-
395
Additional rate for excavation of one Earth Pit (2.5m depth) in Soft Rock.
8
-
1735
Providing one Coil Earth using GI earth wire, digging separate pit at standard distance away from the pole/structure & backfilling.
4
-
723
Fitting one set (3No.) 11kV LA and giving connections excluding earthing.
5
-
320
Fitting one set (3No.) 11kV DO Fuse and giving connection.
1
-
320
Fitting one set AB switch and giving connection
9
-
1859
Fitting one Additional V cross arm in existing single pole incl. conveyance of materials.
11
-
320
Fitting one Additional 75x40mm, 1.8m Channel cross arm in existing single pole incl. conveyance of materials.
3
-
320
Fitting one Additional 2.4m/3m Channel cross arm (100x50x6mm), in existing 11kV DP incl. conveyance of materials.
59
-
376
Fitting one Additional 3m Channel cross arm (35x35x5mm), in existing 11kV DP incl. conveyance of materials.
14
-
353
Fitting one LT 2 line cross arm on HT or LT existing poles incl. fitting insulators and binding the same with LT Line.
63
-
93
Fitting one LT 4 line cross arm on HT or LT existing poles incl. fitting insulators and binding the same with LT Line.
13
-
139
Fitting one additional HT pin with insulator
33
-
99
Fitting one additional F top bracket
7
-
99
Insertion of one HT PSC pole in existing HT/LT line incl. digging & back filling pit, fitting cross arm, insulator, binding etc.
1
-
2720
Dismantling one damaged LT PSC/RCC pole after disconnecting stays, strut etc. and stacking the same.
1
-
671
Dismantling one LT 2 line cross arm from existing pole.
15
-
46
Dismantling one LT 4 line cross arm from existing pole.
4
-
70
Dismantling (without damage) one span of HT or LT cradling and stacking the same neatly and in good condition for re-use.
1
-
815
Dismantling (without damage) one km LT Sph 2 wire OH line, cross arms, insulators and stacking the conductors in rolls.
0.04
-
4952
Dismantling (without damage) one km LT 3ph 4 wire OH line, cross arms, insulators and stacking the conductors in rolls.
0.16
-
9401
Dismantling (without damage) one km LT additional conductor line, cross arms, insulators and stacking the conductors in rolls.
0.04
-
2230
Additional rate for refitting/redoing one Shackle set and reshackling one span while renewing any type of pole.
43
-
227
Renewing one LT Jumper connection usingCopper/ACSR conductor as per standard specification.
8
-
67
Dismantling and reconnecting 3ph service connection from the OH line incl. lowering down the WP portion.
5
-
99
Stringing one km LT Sph 3 wire line (Rabbit for Ph&N, Weasel for St.main) incl. fitting cross arm etc. removing touchings and conveyance of materials.
0.04
-
15798
Stringing one km LT 3ph 4 wire line (Rabbit for Ph, Weasel for N) incl. fitting cross arm etc. removing touchings and conveyance of materials.
0.143
-
21250
Excavation of cable trench in all classes of soil and backfilling after laying of cable (excluding laying of cable).
800
-
197
Additional rate for excavation of cable trench in exceptionally hard conditions ( like in *ordinary rock).
600
-
112
Additional rate for excavating trench on tarred/concrete surface of specified size.
200
-
181
Laying HT XLPE UG cable (of sizes beyond 3x185 sqmm and upto and incl. 3x300 sqmm) as per specification excl. excavation and backfilling.
800
-
349
Mounting the cable ends of all sizes upto and incl. 3x300 sq mm with special type cable clamps incl. cost of extra materials if needed and giving necessary connections.
8
-
778
Doing one cable end termination on cables of sizes beyond 3x185 sqmm and upto and incl. 3x300 sq mm using the cable jointing kit supplied departmentally.
8
-
1281
Doing straight joint on cables of sizes beyond 3x185 sqmm and upto and incl. 3x300 sq mm using the cable jointing kit supplied departmentally as per specification.
3
-
2148
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements