Kerala State Electricity Board Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Kerala State Electricity Board - KSEB Tender
Electrical and Electronics
Eprocure
Opening Date15 Dec 2022
Closing Date23 Dec 2022
Tender Amount₹ 5,81,198
Costs
EMD
₹ 29,100Document Cost
₹ 2,360Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_KSEB_539787_1Bid Award Id
ViewTender No
01/AEE-KZHY/22-23/14-12-2022Tender Authority
Kerala State Electricity Board ViewPurchaser Address
-Website
http://etenders.kerala.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Transporting poles by hired vehicle to a distance upto 5km and carrying upto 4 poles excluding loading & unloading.
2
-
1428.57
Dismantling (without damage) one 11kV PSC/RCC pole after disconnecting stays, strut etc. and stacking the same.
3
-
2081
Dismantling (without damage) one 11kV A type pole after disconnecting stays, strut etc. and stacking the same.
2
-
2082
Dismantling one damaged HT TW/RSJ/Rail Strut pole incl. removal of clamps and stacking.
1
-
552
Dismantling (without damage) one km 11kV line (3 conductors), cross arm, insulators, disc, rolling the conductor and stacking.
0.36
-
9198
Dismantling (without damage) one HT stay incl. back filling, and bringing back to section store.
2
-
601
Dismantling one V cross arm/Channel cross arm from existing Pole, and bringing back to section store.
2
-
128
Renewing one 11kV Jumper connection using Copper/ACSR conductor as per standard specification.
6
-
201
Drilling hole of various sizes on existing Channel/Cross Arm.
30
-
11
Drilling oval shaped hole of various sizes on existing Channel/Cross Arm/GI/MS cleat etc.
10
-
28
Fitting and erecting one HT A type Pole in position incl. fitting cross arm, digging & back filling pit, drawing earth leads.
5
-
2756
Additional rate for providing one disc set on any type of HT pole for making cut point.
6
-
105
Fitting and erecting one HT DP using A type pole in position incl. fitting 2 channel cross arms, digging & back filling pit, drawing earth leads.
1
-
6967
Fitting and providing one HT Stay for 11kV pole incl. digging & back filling pit.
2
-
914
Additional rate for excavation of Pit for A type pole in Laterite.
4
-
434
Additional rate for excavation of Pit for A type pole in Hard Laterite.
7
-
867
Additional rate for excavation of Pit for A type pole in Soft Rock.
3
-
1301
Stringing of one km 11kV line with ACSR Raccoon (3 conductors) incl. cutting and removing tree branches wherever necessary.
0.22
-
23128
Fitting one additional Fuse unit and giving connection from Transformer to fuse and DB to LT OH line.
4
-
233
Fitting one set AB switch and giving connection
1
-
1859
Fitting one Additional 75x40mm, 1.8m Channel cross arm in existing single pole incl. conveyance of materials.
2
-
320
Fitting one Additional 2.4m/3m Channel cross arm (100x50x6mm), in existing 11kV DP incl. conveyance of materials.
8
-
376
Fitting one LT 4 line cross arm on HT or LT existing poles incl. fitting insulators and binding the same with LT Line.
3
-
139
Dismantling (without damage) one LT PSC/RCC pole after disconnecting stays, strut etc. and stacking the same.
1
-
1280
Dismantling (without damage) one km LT 3ph 4 wire OH line, cross arms, insulators and stacking the conductors in rolls.
0.4
-
9401
Dismantling (without damage) one km LT additional conductor line, cross arms, insulators and stacking the conductors in rolls.
0.4
-
2230
Additional rate for refitting/redoing one Shackle set and reshackling one span while renewing any type of pole.
10
-
227
Dismantling and reconnecting Sph service connection from the OH line incl. lowering down the WP portion.
35
-
64
Dismantling and reconnecting 3ph service connection from the OH line incl. lowering down the WP portion.
20
-
99
Providing Strut using LT PSC pole incl. digging & back filling pit.
2
-
1256
Stringing one km LT 3ph 5 wire line (Rabbit for Ph and Weasel for N&St.main) incl. fitting cross arm etc. removing touchings and conveyance of materials.
0.04
-
25771
Dismantling one set 2x40 W fluorescent tube fitting from pole, repairing and refitting the same in position and giving connection.
7
-
501
Doing one cable end termination on cables of sizes beyond 3x185 sqmm and upto and incl. 3x300 sq mm using the cable jointing kit supplied departmentally.
4
-
1281
Mounting the cable ends of all sizes upto and incl. 3x300 sq mm with special type cable clamps incl. cost of extra materials if needed and giving necessary connections.
2
-
778
Providing concrete muffing (0.45x0.45x1.5m) inclusive of cost of all material (as per specification).
7
-
3802
Stringing of 1.1 kV Aerial bunched cable of size 3 x 70
+ 1 x 16+1x 50 sqmm with bare/insulated Messenger through existing poles
500
-
38.76
Erection of Anchor clamp / dead end clamp for LT ABC of any size
25
-
157.51
Erection of suspension clamp for LT ABC of any size
15
-
157.51
Providing Cable Tie
100
-
3.68
Installing One No. Insulation piercing connector of size Main :16 to 95 ,Tap:1.5 to 16 Sq.mm
50
-
55.27
Installation of Insulation piercing connector for main to service line main :16-95 sqmm, Tap : 4-35 sqmm
120
-
55.27
Providing End Caps
60
-
6.07
Dismantling of 11 kV Aerial bunched cable XLPE insulated of size 3 x 120+ 1 x 95 sqmm with bare insulated Messenger
50
-
21.82
Stringing of 11 kV Aerial bunched cable of size 3 x 120
+ 1 x 95 sqmm with bare/insulated Messenger through existing poles
50
-
43.64
Dismantling of 1.1 kV Aerial bunched cable of size 3 x 70
+ 1 x 16 (Street Light) + 1 x
50 Sq.mm. (Insulated Messenger)
80
-
18.97
Dismantling of Anchor clamp
/ dead end clamp for LT AB cable
4
-
73.7
Horizontal Direct drilling HDD 200MM bore (110mm HDPE Pipe)Horizontal Direct Drilling along /accross roads,supplying and pulling 110 mm HDPE Pipe duct (3core 3x300mm2 XLPE UG CABLE including surveving the site for collecting information about under ground utility)
200
-
2000