Kerala State Electricity Board Tender
... More
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 26,100Document Cost
₹ 5,900Tender Fee
Refer Documents
Summary
Lt Reconductoring With Abc Under Koovachira And Kunnumpuram Dtr At Electrical Section, Mayyanad
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_KSEB_563170_1Tender No
ESD/KTYM/05/22-23/DTD 02.03.2023Tender Authority
Kerala State Electricity Board ViewPurchaser Address
-Website
http://etenders.kerala.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Suspension Clamp for LT AB Cables 70 sq.mm
110
44000
400
... More
Stainless Steel Strap [20 mm x 0.7 mm]
340
13600
40
... More
Stainless Steel Buckles[ 20.5 mm x 1.5 mm; thickness 1.2 mm]
340
6800
20
... More
Insulation piercing Connector - Main 16 sq mm to 95 sq mm; Tap 4sq.mm to 50 sq mm(4 way)
100
13000
130
... More
Insulation piercing Connector (IPC Connector) Main 16 sq mm to 95 sq mm; Tap 4 sq.mm to 35 sq mm(4 way)
100
13000
130
... More
Insulation piercing Connector- Main 16 sq mm to 95 sq mm; Tap 1.5 sq.mm to 16 sq mm
100
6900
69
... More
Insulation piercing Connector- Main 16 sq mm to 95 sq mm; Tap 16 sq.mm to 95 sq mm
100
11400
114
... More
Cable Tie UV Plast Heavy Duty 300m
500
5750
11.5
... More
End Cap for ABC 70 sq mm
130
1950
15
... More
Earthing Set ( Spiral )
12
4140
345
... More
LABOUR
-
-
-
... More
Stringing of 1.1 kV Aerial bunched
cable of size 3 x 70 + 1 x 16+1x 50
sqmm with bare/insulated Messenger
through existing poles
4215
163373
38.76
... More
Loading LT PSC pole from the stacking place and unloading the same at work site (transport by vehicle)
8
2552
319
... More
Transporting poles by hired vehicle to a distance upto 5 km and carrying upto 4 poles excluding loading & unloading
2
2857
1428.57
... More
Erecting one LT PSC Pole in position incl. Digging & back filling pit
8
10736
1342
... More
Providing Stay for LT poles incl.digging & back filling pit
8
5000
625
... More
Dismantling and reconnecting Sph service connection from the OH line incl. Lowering down the WP portion
150
9600
64
... More
Dismantling and reconnecting 3ph service connection from the OH line incl. Lowering down the WP portion
30
2970
99
... More
Dismantling one 2x40 W flourescent tube fitting from the existing pole and refitting the same on newly erected pole and reconnecting
10
5010
501
... More
Erection of Anchor clamp / dead end clamp for LT ABC of any size
60
9450
157.51
... More
Erection of suspension clamp for LT ABC of any size
110
17326
157.51
... More
Installing One No 4 way Satellite Connector of size Main: 16 to 95, Tap: 4 to 35 sq mm to the LT AB Cable of Standard size
100
4606
46.06
... More
Installation of Insulation piercing connector for main to service line main : 16-95 sqmm, Tap : 4-35 sqmm
100
5527
55.27
... More
installing one no insulation piercing connector of size Main: 16 to 95, Tap : 1.5 to 16 sq mm
100
5527
55.27
... More
Installation of Insulation piercing connector for main to service line main : 16-95 sqmm, Tap : 16-95 sqmm
100
5527
55.27
... More
Providing Cable Tie
500
1840
3.68
... More
Providing End Caps
130
789
6.07
... More
Fitting one additional fuse unit and giving connection from Transformer to fuse and DB to LT OH line
10
2330
233
... More
Additional rate for excavation of one pit for LT Pole /LT stay in Laterite
10
1450
145
... More
Dismantling ( without damage) one km LT 3ph 4 wire OH line, cross arms, insulators and stacking the conductors in rolls
1
9401
9401
... More
Dismantling ( without damage) one km LT additional conductor line, cross arms, insulators and stacking the conductors in rolls
0.5
1115
2230
... More
Dismantling ( without damage) one km LT Sph 2 wire OH line, cross arms, insulators and stacking the conductors in rolls
2.72
13444
4952
... More
Providing one coil Earth using GI earth wire, digging seperate pit at standard distance away from the pole/structure & backfilling
12
8676
723
... More
Fitting one LT 2 line cross arm on HT or LT existing poles incl. Fitting insulators and binding the same with LT line
8
744
93
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements