Kerala State Electricity Board Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kerala State Electricity Board - KSEB Tender

Works
Civil And Construction
Eprocure
Opening Date26 Nov 2024
Closing Date11 Dec 2024
Tender Amount₹ 22,88,032 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Demolishing Cement concrete manually/mechanical means of Road surface including disposal of materials within 50m lead etc. complete as per the direction of the Board staff

2

2045

4090.28

... More
Demolishing RCC work manually/by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer in charge

2

2983

5967.22

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)

12

6814

81778.68

... More
Stub setting for yard structures in correct alignment using template, water level etc in concrete foundation excluding cost of excavation, concreting and back filling but including grouting anchoring etc. and removing stub setting template after the predetermined setting period etc. complete as per specifications and directions of departmental officers at site

1

1185

1185.68

... More
Setting up anchor bolt in correct alignment using template or water level etc in concrete foundation excluding cost of excavation, concreting and back filling but including grouting anchoring etc. and removing template after the predetermined setting period etc. complete as per specifications and directions of departmental officers at site

25

200

5009.25

... More
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete

110

335

36884.1

... More
Centering and shuttering including strutting, propping etc. and removal of form for Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc

70

717

50205.4

... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone 20 mm nominal size) for yard equipment foundation work and cable trench

40

9085

363405.2

... More
Providing, hoisting and fixing up to floor five level precast reinforced cement concrete work and placing cover slabs for cable trench including the cost of required centering, shuttering but excluding cost of reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone 20 mm nominal size).

2

10565

21131.08

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level using Thermo-Mechanically Treated bars

3745

98

368133.5

... More
Plastering with cement mortar 1:4, (1 cement, 4 course sand )12 mm thick one coat floated hard and trowelled smooth for underside of slabs, side and bottom of beam, column outer face etc including watering, curing etc. complete.for cable trench and foundation sides

140

325

45505.6

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m

120

258

31027.2

... More
Loading one 110/66kV CT / CVT / PT / CC from the place of its storage to department lorry using required lifting device without causing any damage to equipment and its parts.

6

2724

16349.16

... More
Unloading one 110/66 kV CT/PT/CVT/CC from department lorry to substation site using suitable lifting device and dragging to safe place without causing any damage to CT as per the direction of the department officers.

6

2043

12261.9

... More
Loading one set 110/66kV Circuit breaker with its interrupting poles, mechanism box, structures and all its accessories safely without causing any damage using necessary lifting devices to department lorry and fastening for transportation.

1

6444

6444.9

... More
Unloading one set 110/66kV Circuit breaker with its interrupting poles, mechanism box, structures and all its accessories safely without causing any damage using necessary lifting devices from department lorry to substation site and stacking properly for safe storage.

1

4833

4833.68

... More
Loading one set 110/66kV Bus Isolator with its insulator stacks, supporting channels, connecting pipes, isolating rods, mechanism box, structures and all its accessories safely without causing any damage using necessary lifting devices to department lorry and fastening for transportation.

1

1816

1816.57

... More
Unloading one set 110/66kV bus isolator with its insulator stacks, supporting channels, connecting pipes, isolating rods, mechanism box, structures and all its accessories safely without causing any damage using necessary lifting devices from department lorry to substation compound and stacking properly for safe storage.

1

1362

1362.43

... More
Loading one set 110/66kV Line Isolator with its insulator stacks, supporting channels, connecting pipes, isolating rods, mechanism box, structures and all its accessories safely without causing any damage using necessary lifting devices to department lorry and fastening for transportation.

1

1816

1816.57

... More
Unloading one set 110/66kV Line Isolator with its insulator stacks, supporting channels, connecting pipes, isolating rods, mechanism box, structures and all its accessories safely without causing any damage using necessary lifting devices from department lorry to substation compound and stacking properly for safe storage.

1

1362

1362.43

... More
Loading one 110/66kV LA from the place of its storage to department lorry, if required, after dragging up to 50M using suitable lifting device carefully without causing any damage to equipments and fastening in the lorry make it ready for transportation as per the direction of the department officers

3

490

1472.46

... More
Unloading one 110/66kV LA from department lorry to substation site using suitable lifting device and dragging to safe place without causing any damage to LA as per the direction of the department officers

3

368

1104.36

... More
Loading MS / GI materials hard ware fittings of line work and clamps for equipments and bus from the place of its storage to department lorry and make it ready for transportation as per the direction of departmental officers.

8

942

7537.6

... More
Unloading MS / GI materials hard ware fittings of line work and clamps for equipments and bus from department lorry to substation site and stacking for proper storage as per the direction of departmental officers.

8

471

3768.8

... More
Erection of 1 No. 110/66KV CT/PT/CVT/ CC/220KV NCT on the already erected structure of above 1.5m height after opening of crates at the place of storage, leading to site carefully keeping at vertically not allowing tilting from vertical position more than the specified angles, keeping lines and levels as per the direction of the departmental officers, including all labour charges, hire charges of tools & tackles etc.

6

5929

35579.28

... More
Erection of one set 110/66KV Bus Isolator on the already erected structure including opening crates and conveyance of all accessories from the place of storage to the place of erection to lines and levels, erection of mechanism box , checking operation and aligning properly, including cutting, welding etc. complete as per the direction of departmental officers.

1

13584

13584.36

... More
Erection of one set 110/66KV Line Isolator on the already erected structure including opening crates and conveyance of all accessories from the place of storage to the place of erection to lines and levels, erection of mechanism box , checking operation and aligning properly, including cutting, welding etc. complete as per the direction of departmental officers.

1

14942

14942.8

... More
Erection of 1 No. 110/66KV LA/Post insulator on the already erected structure after opening of crates at the place of storage leading to site carefully, keeping lines and levels as per the direction of the departmental officers.

3

3084

9254.07

... More
Unpacking carefully and leading one set of 3 Pole EHT110/66KV Circuit Breaker from the place of storage, including support structure, mechanism box compressor, pipe lines etc. to site, cleaning and erecting on foundation using suitable lifting tools, after disassembling necessary parts if required, to lines and levels and assembling all the parts, connecting mechanism etc. in complete shape and making ready for commissioning as per the direction of departmental officers.

1

36283

36283.91

... More
Providing one wave trap for PLCC on the existing 66/110 kV line using armour rods, suspension clamps etc. including giving connection from line to wave trap, wave trap to isolator using compressed sockets etc. as per the direction of departmental officers.

2

4625

9251.22

... More
Distmantling one wave trap for PLCC from the existing 66/110 kV line using armour rods, suspension clamps etc. including distmantling connection from line to wave trap, wave trap to isolator as per the direction of departmental officers.

2

2312

4625.62

... More
Uncoiling, paving out, stringing and fixing of bus bar using ACSR Kundah / Moose single conductor for one phase of 66/110KV bus of span up to 30M by cutting the conductor to sufficient length, crimping using compressor / bolting the two ends, washing, cleaning and drying the insulator discs, fixing the conductors to the yard structure with sufficient tension using string of insulators and hardware complete at both ends, fixing of arcing hornes including transportation of materials from the stockyard to the site under the supervision and direction of Board Officials at site. (All materials will be supplied departmentally at free of cost).

3

5260

15782.34

... More
Dismantling of bus bar using ACSR Kundah / Moose single conductor for one phase of 66/110KV bus of span above 30M including transportation of materials from the site to the stockyard under the supervision and direction of Board Officials at site. (All materials will be supplied departmentally at free of cost).

3

1315

3945.6

... More
Stringing and fixing earth wire of size 7/9, 7/10 or 7/3.15 between top of the columns and to terminal tower at 33/66/110/220kV substations with compressed / bolted ends at proper tension including uncoiling and cutting of conductor , jumpering, giving earth bond connections by drawing the end of the conductor through the columns, jointing where ever necessary providing back stays at the time of stringing etc. as per the direction of the departmental officers.

10

2606

26062.5

... More
Providing interconnection between equipments using ACSR Moose/ Kundah/ wolf Single conductor at both ends with compressed/ bolted ends including uncoiling and cutting of conductor as per the direction of departmental officers.

15

1036

15551.4

... More
Providing droppers and connecting to lines / equipments or jumper between two buses without suspension insulators using ACSR Moose/ Kundah/ wolf Single conductor at both ends with compressed/ bolted ends including uncoiling and cutting of conductor as per the direction of departmental officers. (For one phase)

8

1244

9952.16

... More
Unpacking the transformer / feeder C&R panels, 110V battery charger, OLTC cubicle LT panel at the place of storage transporting to the place of erection and erecting after providing foundation bolt keeping to lines and levels as per the direction of departmental staff.

1

4871

4871.83

... More
Preparing wiring schedule per transformer / feeder bay of 33 kV with details of type of cable, core and colour, ferrule No. and terminal no of equipments/panels including giving full details in A4 sheet with computer print providing outer border line and sheet no etc. and supplying in the shape of book with special binding etc. and assisting the departmental officers at the time of relay testing and commissioning as Master copy

1

8472

8472.29

... More
Additional copy of the above with spiral binding

3

230

690

... More
Fixing departmentally supplied marshalling kiosk in the existing PT/CT structure by making suitable fixing arrangements including cutting , welding, drilling holes etc as required.

2

643

1286.58

... More
Uncoiling 20/19 core 2.5sqmm, 12 core 4 sqmm control cable (Armoured or un armoured) from cable drums cutting to required length and laying through trench/pipe/cable tray grouping the same neatly using cable tie and carefully including for providing loop wherever necessary and providing cable marker at both ends of cable as per direction of departmental staff at site.

400

51

20560

... More
Uncoiling 12/7/6 core 2.5 sq mm control cable (armoured and un armoured) from cable drums and cutting to required length and laying through trench/pipe/cable tray grouping the same neatly using cable tie and carefully including for providing loops wherever necessary and cable marker, at both ends of cable as per direction of departmental staff at site.

400

38

15340

... More
Uncoiling 4/2 core 2.5sqmm control cable (armored or unarmored) from cable drums and cutting to required length and laying through trench/pipe/cable tray neatly and carefully including for providing loops wherever necessary and cable marker at both ends of cable as per direction of departmental staff at site.

350

37

13041

... More
Uncoiling 5/4/3/2 core 4sqmm control cable(armoured or un armoured) from cable drums and laying through trench/pipe/cable tray neatly and carefully including for providing loops wherever necessary and cable marker at both ends of cable as per direction of departmental staff at site.

100

35

3598

... More
Termination of cables in panel by using cable glands of fixing the cable rigidly by any means as per direction of departmental staff at site charges include for providing necessary suitable hole in the gland plate etc. 20/19 core 2.5 sqmm cable/12 core 4 sqmm cable (using gland of size 28-32mm)

10

260

2603.1

... More
Termination of cables in panel by using cable glands of fixing the cable rigidly by any means as per direction of departmental staff at site charges include for providing necessary suitable hole in the gland plate etc.12/7/6 core 2.5 sqmm cable (using gland of size 25mm)

6

230

1384.08

... More
Termination of cables in panel by using cable glands of fixing the cable rigidly by any means as per direction of departmental staff at site charges include for providing necessary suitable hole in the gland plate etc. 4/2 core 2.5 sq mm cable/4/2 core 4.0 sq mm cable (using gland of size 16-22mm)

20

219

4386.8

... More
Doing termination of all sizes of PVC insulated copper control cable 2.5 mm², pealing, providing number and letter ferrules in the wire, stripping ends, crimping with suitable lugs and connecting to the terminals in the panel board and marshalling kiosk etc., neatly and carefully including cost of copper sockets and ferrules as per the direction of Departmental Officers at site.

200

63

12624

... More
Doing termination of all sizes of PVC insulated copper control cable 4.0 mm², pealing, providing number and letter ferrules in the wire, stripping ends, crimping with suitable lugs and connecting to the terminals in the panel board and marshalling kiosk etc., using cable tie and cable tie neatly and carefully including cost of copper sockets and ferrules as per the direction of Departmental Officers at site.

50

63

3163

... More
Supplying aluminium cable tags punching number and alphabets up to 7 digits and binding to cable using copper wire including cost of all materials as per the direction of Board Officials at site.

100

71

7112

... More
Supplying and fixing 110mm PVC vent pipe (8Kgf/cm2) & specials such as bends etc with all fittings, including cutting, excavation etc for carrying control cables from marshelling kiosks to main trenches etc. Complete as per the directions of the departmental officers at site.

50

582

29139

... More
Levelling, Cutting and fixing in position contractor supplied MS Chequered plate 6 mm, 10 mm or 12mm thick in suitable length and width including providing lifting legs and suitable holes for lifting including grinding sides and corners etc. complete.

0.5

10742

5371.48

... More
Fabrication of structures for erecting equipments. The GI & MS angles will be supplied departmentally

20

3635

72715

... More
Drilling holes in yard structure

100

55

5564

... More
Cutting of steel angle in yard structure erection

50

203

10167.5

... More
Welding charge for welding on iron parts using arc welding as per standards

50

106

5327.5

... More
Erection of yard structures and assembling of columns and beams using bolt and nut including punching of holes.

6

7723

46338.6

... More
Cutting 32mm MS rod in required length etc complete as per the direction of the departmental officers.

130

86

11199.5

... More
Bending 32 mm MS rod for crossing cable trench/foundations/risers etc.

50

126

6322

... More
Laying of earth mat of required size as specified using 40/32/25mm MS rod including levelling lowering and placing in trenches, complete as per the direction of departmental officers.

35

1040

36418.2

... More
Driving down the ground electrode upto a depth of 3 Mts from the already taken earth pit as directed by the departmental officers.

20

170

3406.6

... More
Drilling holes and driving down MS ground electrode from the bottom level of trench in all classes of soil including rock etc. complete as per the directions of department officers

30

214

6437.1

... More
Welding of overlapping joints for mat,riser lap joints with 32/25mm MS rod placed in trenches, having 150mm in length 6mm in thick on both sides of the rod and both ends of overlapped MS rods with 6mm welding thickness after cleaning the surfaces neatly. Charges includes cost of low hydrogen DC electrode (No. E7018), hire charges of DC arc welding set and tools and plants required, current charges including labour charges for holding MS rod in position and applying two coats of anti corrosive paints at the welded joints etc. complete as per the directions of department officers.

60

636

38166.6

... More
Welding the nodal points (cross joints ) in the trenches at two sides to a thickness of 6mm after cleaning the surface neatly. Charges includes cost of low hydrogen DC electrodes (No. E7018), hire charges of DC welding set and tools and plants required, current charges, labour charges for holding MS rod in position and applying two coats of anti corrosive paints at the welded joints etc. complete as per the directions of departmental officers.

210

300

63159.6

... More
Welding the ground electrode with the main electrode , after cleaning the surface neatly. Charges includes cost of low hydrogen content DC electrodes (No. E7018), hire charges of DC arc welding set, tools and plants, current charges, labour charges for holding MS rod in position and applying two coats of anti corrosive paints at the welded joints etc. complete as per the directions of departmental officers.

30

385

11550

... More
Laying of departmentally supplied GI strip/Copper strip of suitable size including cleaning and neatly bending of strips ,cutting, removing of metal/earth in the yard and burying earth strip to the required depth re-doing the yard metalling as per the direction of the departmental officers.

250

180

45215

... More
Welding one end of the bended GI strip of size 50x6mm with the riser of the already laid earth mat, welding 150mm in length, 6mm thick on both sides & end of the strip & other end of the strip with yard structure at 2 points 50mm apart each welding points having 50mm length and 6mm thick on both sides & end of the strip including the charges for connecting the strip with structure using bolted joints as per the directions of the department officers. Charges includes hire charges of DC arc welding set, current charges, cost of low hydrogen content DC arc welding electrodes(No.E7018) cost of anti corrosive paint etc. complete.

40

539

21584

... More
Welding overlapping joints of 50x6mm GI strip with 50mm long, 6mm thick welding on all three sides after doing 2 Nos. bolted joints at the centre as specified after cleaning the surface. Charges includes hire charges of DC arc welding set, current charges, cost of low hydrogen content DC arc welding electrodes( No.E7018) cost of anti corrosive paint etc. complete.

20

273

5477.6

... More
Welding one end of the bended GI strip of size 50x6mm with the riser of the already laid earth mat, welding 150mm in length, 6mm thick on both sides & end of the strip and connecting other end with nuts & bolts if required as per the directions of the department officers. Charges includes hire charges of DC arc welding set, current charges, cost of low hydrogen content DC arc welding electrodes(No.E7018) cost of anti corrosive paint etc. complete.

5

508

2543.95

... More
Welding one end of the GI strip 50x6mm with the structure with a welding length of 50mm & 6mm thickness on both sides & end of the strip and connecting other end with bolts & nuts if required including hire charges of DC arc welding set, current charges, cost of low hydrogen DC arc welding electrodes (No.E7018) cost of anti corrosive paint etc. complete.

5

364

1823.1

... More
Supplying and stacking 6mm broken stone for measurements(for yard metalling )

60

2344

140688.6

... More
Supplying and stacking 40mm broken stone for measurements(for yard metalling )

90

2188

196999.2

... More
Spreading 6 mm broken stone upto a thickness of 10 cm in yard/ pit as per the direction of departmental officers.

550

30

16599

... More
Spreading 40 mm broken stone upto a thickness of 15 cm in yard as per the direction of departmental officers.

559

64

36150.53

... More
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coats of approved steel primer and two coats of synthetic enamel paint all complete for cable trays ,fixing of panels, chequer plate support, etc as per the direction of dept officers .(angles,channels dept supply)

4.5

4362

19631.16

... More
Shifting the covering slab of sizes 1000 x 650X 18 from top of cable trench to a nearby convenient place and replaced to top of cable trench after cable laying work etc complete.as per thedirection of department officers at site

20

159

3194.2

... More
Shifting the covering slab of sizes 650X 500X5mm from top of cable trench to a nearby convenient place and replaced to top of cable trench after cable laying work etc complete.as per thedirection of department officers at site

100

86

8663



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.