Kerala State Electricity Board Tender

... More
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kerala State Electricity Board - KSEB Tender

Works
Civil And Construction
Building Construction
Electrical and Electronics
Electrical Works
Eprocure
Opening Date25 Mar 2025
Closing Date15 Apr 2025
Tender Amount₹ 13,13,536 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar

1

1730

1730.2

... More
Dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:Of area 3 sq. metres and below

4

323

1292.44

... More
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

25

296

7423.5

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

5.96

7367

43932.7

... More
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)

12

7204

86457.36

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

18

258

4654.26

... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size

6

9085

54510.84

... More
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)

2.5

10954

27385.1

... More
Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement :1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).

1

11492

11492.88

... More
Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

3

335

1005.93

... More
Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

24

717

17212.8

... More
Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs,landings, balconies and access platform

11

815

8973.58

... More
Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams,girders bressumers and cantilevers

14

649

9097.48

... More
Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide

30

203

6117.9

... More
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

700

98

68810

... More
Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete

8

6644

53152.96

... More
Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete

3

6984

20954.55

... More
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes

550

168

92845.5

... More
Providing and fixing Sandwich puff roof sheet. (Puf thick 30mm polyurethane core, Fire property B3 as per BIN4102, K value 0.020 W/mk, water absorption 1% of volume and Overall heat transfer. W/ M2) Top sheet 0.53mm TATA BlueScope Colourbond AZ150 GSM bottom sheet .38mm TATA Steel AZ 150 precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer- in-charge) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length up to 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self-drilling /self-tapping corroshield size (100mm) with EPDM seal, complete up to any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.

55

2062

113424.3

... More
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.

10

738

7386.9

... More
12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

125

314

39261.25

... More
Pointing on stone work with cement mortar 1:3 ( 1 cement : 3 fine sand):Flush/ Ruled pointing

11

335

3695.89

... More
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

70

119

8385.3

... More
Removing white or colour wash by scrapping and sand papering and preparingthe surface smooth including necessary repairs to scratches etc. complete

85

16

1423.75

... More
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work

15

223

3349.8

... More
Applying priming coats with primer of approved brand and manufacture, having low VOC ( Volatile Organic Compound) content.With water thinnable cement primer on walls surface having VOC content less than 50 grams/litre

125

70

8830

... More
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work

110

151

16652.9

... More
Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

100

193

19389

... More
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work

30

143

4291.5

... More
Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture including applying additional coats wherever required, to achieve even shade and colour.One coat

10

84

844.7

... More
Providing and laying Polished Granite stone flooring in required design andpatterns, in linear as well as curvilinear portions of the building all complete asper the architectural drawings with 18 mm thick stone slab over 20 mm (average)thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed withcement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete asspecified and as directed by the Engineer-in-Charge.Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent

40

4151

166046.4

... More
Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work

25

442

11071

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS :733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc.Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically whereverrequired including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steelscrews, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing,paneling and dash fasteners to be paid for separately):For fixed portion Powder coated aluminium(minimum thickness of powder coating 50 micron)

65

537

34909.55

... More
For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)

65

643

41801.5

... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness

15

1526

22890

... More
Providing and fixing 4 mm thick ACP sheet with CP brass/ stainless steel screws etc. complete as per the directions of Engineer - in- Charge.

3.5

2098

7345.87

... More
Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. complete as per direction of Engineer-in-Charge.Polyester powder coated minimum thickness 50 micron aluminium

4

104

418.96

... More
Providing and fixing factory made P.V.C. Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary necessary screws etc. complete.Powder coated minimum thickness 50 micron aluminium

28

84

2359.56

... More
Providing and fixing 100 mm brass locks ( best make of approved quality ) for aluminium doors including necessary cutting and making good etc. complete

1

539

539.78

... More
Providing and fixing tiled false ceiling of approved materials of size 595x595 mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams/sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required lengthand of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to centerand cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long space betweenmain "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying falseceiling tiles of approved texture in the grid including, required cutting/making, opening of services likediffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceilingusing GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shallbe pre-painted with polyester paint, all complete for all heights as per pecifications, drawings and asdirected by Engineer-in-charge.8 mm thick fully perforated calcium silicate board made with Calcareous &Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process to givestable crystalline structure with minimum compressive strength 225 Kg/ sq. cm, bending strength 100Kg/sq. cm, of size 595x595 mm, having perforation of dia, 10 mm with minimum perforated area 18%with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.85, with 50mm thick rockwool of 48 Kg/cum backing.

35

2071

72499.35

... More
Removing the cover slab of cable trenches up to a lead of 50 m with out damage or breakage and storing for reuse as per the directions of the departmental officials at site all complete.

4

87

351.52

... More
Providing and laying factory made chamfered edge Cement Concrete paver blocksin footpath, parks, lawns, drive ways or light traffic parking etc, of required strength,thickness & size/ shape, made by table vibratory method using PU mould, laid inrequired colour & pattern over 50mm thick compacted bed of sand, compacting andproper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand andcutting of paver blocks as per required size and pattern, finishing and sweepingextra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.

25

1121

28045

... More
Supplying and fixing PVC rain water gutter of suitable size including necessary fittings such as clamps, screw, end stopper etc., including cost of all materials, labour charges, scaffolding etc.,

10

475

4759

... More
Demolishing and removing old cement plaster and disposal of debris with in a distance of 150m

5

43

219.7

... More
Supplying and fixing wedge expansion hold fastener 0.50" or 12mm dia, 70mm length or nearest available size for fixing cable tray in concrete/ brick surface

20

48

966.6

... More
shifting and laying cover slab

4

87

351.52

... More
Dismantling W.C. Pan of all sizes including disposal of dismantled materialsi/c malba all complete as per directions of Engineer-in-Charge

1

113

113.01

... More
Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid

1

7868

7868.9

... More
Hacking of CC flooring including cleaning for surface etc. complete as perdirection of the Engineer-in-per direction of the Engineer-in-Charge.

25

2

74.5

... More
Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge.

1

758

758.12

... More
Providing and fixing uplasticised PVC connection pipe with brass unions:45 cm length15 mm nominal bore

2

97

195.38

... More
Providing and fixing C.P brass bib cock of approved quality conforming to IS: 8931.15 mm nominal bore

2

493

986.28

... More
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore

3

626

1878.66

... More
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm

5

64

323.05

... More
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., commplete.Size of Tile 600 x 600 mm.

5

1766

8831.3

... More
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mm

5

284

1421

... More
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter

10

359

3591.1

... More
Providing and fixing stainless steel (SS 304 grade) adjustable friction window stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineer - in- Charge complete.255 x 19 mm

145

379

55069.55

... More
Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:250x10 mm

6

121

731.4

... More
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wireof adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x0.90 mm M.S. laths with 0.90 mm thick to cover

6

3124

18745.56

... More
Providing and fixing PVC pipes includes joints of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in CHarge. 110 mm dia 4 Kg/cm2

2

476

952.34

... More
Acid washing using diluted HCL to remove dust and other small scratches from vitrified/ceramic floor including cost and conveyance of all materials.

8

28

229.52

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLSPVCinsulated copper conductor single core cable in surface / recessed medium class PVCconduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.1.10.1 Group A

9

852

7675.74

... More
1.10.2 Group B

8

930

7441.2

... More
1.10.3 Group C

8

1176

9415.36

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 1.21.1 20 mm)

60

98

5938.8

... More
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required(1.7.2 2X2.5 sq.mm+1X2.5 sq.mm earth wire)

50

272

13627

... More
Supplying and fixing following modular switch/ socket on the existing modular plate &switch box including connections but excluding modular plate etc. as required.1.24.1 5/6 amps switch

5

101

508.45

... More
Supplying and fixing following modular switch/ socket on the existing modular plate &switch box including connections but excluding modular plate etc. as required. 1.24.3 15/16 amp switch

2

155

311.86

... More
1.24 Supplying and fixing following modular switch/ socket on the existing modular plate &switch box including connections but excluding modular plate etc. as required. 1.24.4 3 pin 5/6 amp socket outlet

5

131

657.6

... More
Supplying and fixing following modular switch/ socket on the existing modular plate &switch box including connections but excluding modular plate etc. as required. 1.24.5 6 pin 15/16 amp socket outlet

2

207

414.9

... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 1.27.2 3 Module (100mmX75mm)

2

317

634.56

... More
1.27.4 6 Module (200mmX75mm)

2

395

791.84

... More
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.(1.33 E&M )

27

77

2086.83

... More
Supplying and fixing brass batten/ angle holder including connection etc. as required.(1.34 E&M )

2

138

276.6

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.10.1 Single pole

5

237

1186.4

... More
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.DsR E &M 5.17

7

151

1063.02

... More
Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required..DSR E &M 1.41

18

199

3587.76

... More
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 em) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.DSR E &M 1.44

4

203

813.56

... More
Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required. Upto 450 mm sweep DSR.1.50.1

3

431

1293.54

... More
2.3 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator 2.3.3 12 way, Double door

1

2440

2440.62

... More
2.12 Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.12.1 40 amps

1

402

402.7

... More
2.14 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.14.2 40 amps

1

2490

2490.79

... More
Uncoiling 4/2 core 2.5sqmm control cable (armored or unarmored) from cable drums and cutting to required length and laying through trench/pipe/cable tray neatly and carefully including for providing loops wherever necessary and cable marker at both ends of cable as per direction of departmental staff at site.(as per item No: 55 of transmission data).

30

37

1117.8



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.