Kerala State Electricity Board Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kerala State Electricity Board - KSEB Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date25 Nov 2024
Closing Date17 Dec 2024
Tender Amount₹ 46,80,950 
Notes
Download

Costs

Summary

Construction Of Second 33kv Feeder To 33kv Substation Vydhyuthibhavanam From 110kv Gis Vennakkara, Palakkad

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Transporting 'A' type 14M pole of all sizes by Hand cart - Normally limited to 4 km (Excluding loading and unloading) Rs.566.64*1.15

60

651

39098.4

... More
Loading HT PSC pole to Hand cart from the stacking place and unloading the same at work site (excluding transportation).

10

457

4579.1

... More
Transporting one HT PSC pole by Hand cart - normally limited to 4km (excluding loading and unloading).

10

457

4579.1

... More
Transporting 12m 'A' type pole of all sizes by Hand cart - normally limited to 4km (excluding loading and unloading).

10

566

5666.4

... More
Loading HT 'A' type pole of all sizes to Hand cart from the stacking place and unloading the same at work site (excluding transportation).

10

506

5060

... More
Transport of materials issued departmentally for the works from departmental stores and distribution to locations for erection including storage if necessary, loading and unloading charges etc ( for an average distance of 5Km by lorry)-Rate as per conveyance statement

-

-

-

... More
Line and Earth conductors

1.38

824

1138.36

... More
Insulators and accessories, Power conductor accessories, Earth conductor accessories etc.

13

916

11908.52

... More
Towers, extensions and other structures and all other materials including earthing materials etc.

7.38

557

4111.1

... More
Transport of materials issued departmentally for the works from departmental stores and distribution to locations for erection including storage if necessary, loading and unloading charges etc ( for an average distance of 1Km by manual labour)-Rate as per conveyance statement

-

-

-

... More
Line and Earth conductors

1.38

815

1125.4

... More
Insulators and accessories, Power conductor accessories, Earth conductor accessories etc.

13

741

9633.91

... More
Towers, extensions and other structures and all other materials including earthing materials etc.

7.38

524

3867.86

... More
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.(For all kind of soil)

30

295

8853

... More
Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.(For ordinary rock)

26

524

13630.24

... More
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on+D39 plan), including dressing of sides and ramming of bottoms, second lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.(For all kind of soil ) for every additional lift of 1.5 m

10

400

4008.1

... More
Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, second lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.(Ordinary or hard rock) for every additional lift of 1.5 m

8

713

5710.64

... More
Additional rate for excavation of Pit for 'A' type 14M pole in Laterite. Rs.651.32*1.15

30

749

22470.6

... More
Additional rate for excavation of Pit for 'A' type 14M pole in Hard Laterite.Rs.1303.68*1.15

10

1499

14992.3

... More
Additional rate for excavation of Pit for 'A' type 14M pole in Soft Rock. Rs.1955*1.15

10

2248

22482.5

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)

6

6772

40636.02

... More
Centering and shuttering including strutting, propping etc. and removal of form work for Foundations, footings, bases for columns

80

333

26659.2

... More
Stub setting or fixing foundation bolts in position in correct line and levels for columns by using the templated supplied departmentally and taking back the templates after setting etc., complete as directed by the departmental officers at site. For Lattice structure - 40% of 110kV Column.

6

1626

9760.92

... More
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete above plinth level.

1950

97

190495.5

... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

32

7941

254123.52

... More
Erection of tower super structure above ground level including erection of normal and special hill side extension members wherever necessary, providing tower accessories like phase, danger and number plates, bird guards, anti climbing devices including tighting, punching and tack welding upto bottom cross arm in the bolt and nut after punching and applying zink rich primer wherever necessary etc. complete, as directed by Board staff (For 110kV DC tower-height 22m) (for 66kV DC Tower ( (a1) x 0.95) Average height 21m) (for 33kV lattice - height 14m - (a1) x 0.64)

7.4

9752

72164.8

... More
Fitting and erecting one HT 'A' type 14M Single Pole in position, including fitting cross arm, digging and back filling pit in ordinary soil (as per standards), drawing sufficient length of GI earthing leads from F clamp through V cross arm to the ground for earthing (excluding provision of earthing). RS.4143.14*1.15

64

4764

304935.04

... More
Fitting and erecting one HT Double Pole Structure using 'A' type 14M pole in position including fitting 2 No. channel cross arm, digging and back filling pit in ordinary soil, drawing sufficient length of GI earthing leads through all cross arms to the ground for earthing (excluding provision of earthing) Rs.10473.36*1.15

4

12044

48177.44

... More
Providing concrete muffing of size 0.45x0.45x1.5m (0.5m above GL and 1m below GL). Excavation 0.45x0.45x1m, concrete (1:3:6, 20mm) 0.45x0.45x1.5m, Plastering (1:3) 12mm 0.45x0.45mx5sides.

68

4028

273923.72

... More
Providing one Earth using GI earth pipe of size 38.1mm dia, 2.5m length including digging separate pit (0.45x0.45x2.5m) at standard distance (1.5m) away from the pole/structure in ordinary soil & backfilling.

80

2266

181324

... More
Additional rate for excavation of one Earth Pit (2.5m depth) in Laterite.

40

868

34750.8

... More
Additional rate for excavation of one Earth Pit (2.5m depth) in Hard Laterite.

20

1737

34751

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to50 m and lift up to 1.5 m.

70

256

17987.9

... More
Additional rate for excavation of one Pit for HT Pole/HT Stay in Laterite.

5

434

2174.55

... More
Additional rate for excavation of one Pit for HT Pole/HT Stay in Hard Laterite

10

868

8687.7

... More
Additional rate for excavation of one Pit for HT Pole/HT Stay in Soft Rock.

5

1303

6518.4

... More
Fitting and providing one HT Stay for 11kV pole, including digging and back filling pit in ordinary soil.(for 14M Pole) Rs.1373.73*1.15

64

1579

101106.56

... More
Fitting and providing one Strut using HT PSC pole including digging & back filling pit.

4

3056

12227.64

... More
Fitting and providing one HT Fly stay for 11kV pole using 'A' type pole including digging and back filling pits in ordinary soil, drawing sufficient length of GI earth leads to the ground for earthing (excluding provision of earthing).

1

5674

5674.73

... More
Fitting one Additional HT V cross arm in existing single pole including conveyance of materials.

20

481

9639

... More
Fitting one LT 4 line cross arm on HT or LT existing poles including fitting insulators and binding the same with LT Line. (For using the angle points of 33kV OH line)

30

210

6304.2

... More
Dismantling (without damage) one km 11kV line (three conductors) including dismantling cross arm, insulators, disc, disconnecting jumper connection, rolling the conductor and stacking the materials.

1

13827

13827.18

... More
Stringing of one km 11kV line with ACSR Raccoon (3 conductors) after fitting insulators and giving jumper connections including cutting and removing tree branches wherever necessary excluding cut point works.

1

34792

34792.73

... More
Dismantling (without damage) one km LT three phase 4 wire OH line conductor by dismantling cross arms, insulators and stacking the conductors in rolls properly.

1

14129

14129.32

... More
Stringing, shackling, fitting cross arms, insulators and binding, giving jumper connection etc. using ACSR Rabbit for Phase and ACSR Weasel for Neutral, for one km LT three phase 4 wire line including cutting and removing tree branches wherever necessary and conveyance of all materials (except poles) from stacking place.

1

31957

31957.45

... More
Dismantling (without damage) one km LT additional conductor line by dismantling cross arms, insulators and stacking the conductors in rolls properly.

1

3351

3351.73

... More
Stringing one km LT Addl conductor (Rabbit) after fitting crossarm, but without realigning existing conductor, including fitting cross arm, insulator etc. removing touchings and conveyance of materials.

1

7665

7665.27

... More
Dismantling (without damage) one km LT single phase 2 wire OH line conductor by dismantling cross arms, insulators and stacking the conductors in rolls properly.

1

7443

7443.64

... More
Stringing, shackling, fitting cross arms, insulators and binding, giving jumper connection etc. using ACSR Rabbit for Phase and Neutral, for one km LT single phase 2 wire line including cutting and removing tree branches wherever necessary and conveyance of all materials (except poles) from stacking place.

1

16967

16967.73

... More
Dismantling one ordinary street light/CFL/LED fitting from existing pole and refitting the same on newly erected pole and reconnecting.

10

492

4924.1

... More
Dismantling SV/MV/Metal halide lamp fitting from the existing pole and refitting the same on newly erected pole and reconnecting (without using aerial lift).

5

2351

11756.15

... More
Dismantling one 1x40W fluorescent tube fitting from the existing pole and refitting the same on newly erected pole and reconnecting.

5

611

3057.95

... More
Providing temporary stay during the line stringing work wherever found necessary and as directed.

10

451

4513.3

... More
Paving out, stringing and tensioning as per standard of three line 'ACSR DOG' conductors including attaching insulator strings with arcing horns or rings on to the tower cross arms, clamping the conductor to the insulator strings using suspension clamps with armour rods and tension clamps, jumpering the conductors at tension points, jointing the conductors and pilot wire wherever necessary, installation of vibration dampers, hire charges of tractor and stringing tools, all hire and labour for protective trestle work, providing suitable back stays at the time of stringing, etc. Complete.

3.5

90290

316017.91

... More
Erection of one set 33KV bus Isolator on the already erected structure including opening crates and conveyance of all accessories from the place of storage to the place of erection to lines and levels including erection of mechanism box checking operation and aligning properly as per the direction of departmental officers.

3

8310

24931.92

... More
Drilling of holes

300

118

35565

... More
Filing of holes

100

59

5927

... More
Cutting of steel angles

100

237

23709

... More
Rewinding of "DOG ACSR' from dilapidated conductor drums unsuitable for transporting/paving out on to serviceable conductor drums issued departmentally including all hire charges for tools & plants necessary for rewinding

1.5

6090

9135.33

... More
Additional rate for providing one HT Pin with insulator, complete on any type of HT pole.

40

149

5980

... More
Fitting one Additional 75x40, 1.8 m Channel cross arm in existing single pole including conveyance

10

481

4819.5

... More
Re-Tensioning one span 11 kV line incl. replacing insulators, tightening stay, cutting tree branches and conveyance.

5

727

3638.2

... More
Fitting one LT 2 line cross arm on HT or LT existing poles including fitting insulators and binding the same with LT Line.

15

140

2101.35

... More
Reshackling one Span LT 3 Ph 4 wire OH line, replacing insulators, tightening stay, cutting tree branches incl. Conveyance.

15

493

7401.75

... More
Reshackling one Span LT S Ph 2 wire OH line, replacing insulators, tightening stay, cutting tree branches incl.Conveyance.

15

262

3936.15

... More
Dismantling (with out damage) one HT stay including digging pit in all classes of soil and backfilling, and bringing back to section store.

15

904

13564.8

... More
Dismantling (with out damage) LT stay including digging pit in all classes of soil and backfilling

4

469

1877.64

... More
Dismantling (with out damage) one HT PSC/RCC pole after disconnecting stays, strut etc. attached thereon and stacking the same.

10

3129

31290

... More
Dismantling (without damage) one 11kV 'A' type pole after disconnecting stays, strut etc. and stacking the same

4

3130

12520.36

... More
Dismantling (without damage) one LT PSC/RCC pole after disconnecting stays, strut etc. and stacking the same.

10

1923

19236.4

... More
Dismantling (with out damage) one LT PSC/RCC Strut pole including removal of clamps and stacking.

5

1589

7945.45

... More
Disconnecting and lowering down the single phase WP service connection with guy wire from the OH line and reconnecting the same after completing the line Work.

50

96

4809

... More
Disconnecting and lowering down the Three phase WP service connection with guy wire from the OH line and reconnecting the same after completing the line Work.

10

149

1495

... More
Transporting HT PSC pole from the site (after dismantling) to the location near Vennakkara Substation by hired vehicle for a distance of 4km(average distance) including loading and unloading complete as directed by deptl. officers.

5

1547

7738.55

... More
Transporting LT PSC pole from the staking site (after dismantling) to the location near Vennakkara substation Office Store by hired vehicle for a distance of 4 km including loading and unloading complete as directed by deptl. officers.

5

835

4179.8

... More
Fitting one No. Section fuse on LT line with dropping cables,crimping sockets, connecting with bolt&nut etc.

12

240

2885.4

... More
Additional rate for refitting/redoing one Disc set while renewing any type of 11kV cut pole

30

722

21672.3

... More
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in -charge

2.53

1254

3175.13

... More
Fitting one Additional 2.4m/3m Channel cross arm (100x50x6mm), in existing 11kV DP including conveyance of materials.

65

564

36695.75

... More
Laying of departmentally supplied GI strip/Copper strip of suitable size including cleaning and neatly bending of strips ,cutting, removing of metal/earth in the yard and burying earth strip to the required depth re-doing the yard metalling as per the direction of the departmental officers.(for providing special earthing using GI strip)

100

179

17974

... More
Welding one end of the bended GI strip of size 50x6mm with the riser of the already laid earth mat, welding 150mm in length, 6mm thick on both sides and end of the strip connecting other end with nuts & bolts if required as per the directions of the department officers. Charges includes higher charges of DC arc welding set, current charges, cost of low hydrogen content DC arc welding electrodes (No.E7018) cost of anti corrosive paint etc. complete.(for providing special earthing using GI strip)

60

506

30399.6

... More
Welding charge for welding on iron parts using arc welding as per standards

20

112

2249.4

... More
Detailed surveying of the cable route along the alignment fixed by the Board, including excavation of trial pits in all classes of soil 1.2 x 1.00 x 1.50m size(5 Nos/ Km) as per site requirements for identification of existing cables/pipes of other utilities in the proposed cable route at 200 m intervals and junctions for avoiding damages to the existing cablse/pipes and preparation of profile drawing for cable laying and preparation of final cable route in 6 sets of hard and a soft copy in a scale of 1cm:10m indicating the position of Cable joints, position of cable route marker, landmarks, etc. after completing the work and energizing the cable, for the use as a permanent record.

0.5

8631

4315.55

... More
Horizontal directional drilling including supplying and laying 200mm,8PN,100PE HDPE in a single bore in all classes of soil for laying cable including all charges for the hire charges of machinery, surveying the site for collecting information about under ground utilities, sensing the existing utilities using suitable sensing equipments, restoring the damages occurred if any, laying HDPE pipes (160mm, 8PN, 100PE ) through the single hole and including fusing HDPE joints and all sundry expenses etc. complete at the locations specified by the dept. officers.

500

3200

1600000

... More
Laying single run of 200 mm dia GI pipe -B class, with coupling, collars, clamps etc along the culvert / bridge/drain trench already made for looping 1 circuit 33kV three core XLPE cable through pipe for crossing roads, for taking raisers to termination as per drawing and specifications including paving of cable etc. complete, excluding the cost of GI pipe and specials such as coupling collars and sundries complete at the locations specified by the dept. officers.

20

80

1610

... More
Laying 3 x 300 sq mm 33kV XLPE cables in trench including drawing through pipes (HDPE) wherever necessary.

500

306

153045

... More
Doing out door/indoor cable termination of 3x300 mm2 33KV XLPE cable very carefully, observing directions of manufactures and dept. staff; including crimping of socket.

4

7599

30397.6

... More
Doing straight joint of 3x300 mm2 33KV XLPE cable very carefully, observing directions of manufactures and dept. staff; including crimping of socket

2

11399

22798.2

... More
Mounting one 3x300 mm2 33kV XLPE out door cable termination of structures very carefully without causing any damaged to the drilling holes wherever necessary as directed by the departmental officers

4

1413

5655.72

... More
Loading 3x300 sq. mm XLPE cable from its place of storage to department lorry and properly without causing any damage to its insulation and make ready for transporting as per the direction of department officers.

500

36

18055

... More
Unloading 3x300 sq. mm XLPE cable from department lorry to substation site and stacking properly without causing any damage to its insulation as per the direction of department officers.

500

27

13540

... More
Providing and laying factory made chamfered edge Cement Concrete paver blocksin footpath, parks, lawns, drive ways or light traffic parking etc, of required strength,thickness & size/ shape, made by table vibratory method using PU mould, laid inrequired colour & pattern over 50mm thick compacted bed of sand, compacting andproper embedding/laying of inter locking paver blocks into the sand bedding layerthrough vibratory compaction by using plate vibrator, filling the joints with sand andcutting of paver blocks as per required size and pattern, finishing and sweepingextra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.

20

1114

22297

... More
Erection of 1 No. 33KV LA/Post insulator on the already erected structure after opening of crates at the place of storage leading to site carefully, keeping lines and levels as per the direction of the departmental officers.

6

1253

7518

... More
Erection of one set 33KV Bus Isolator on the already erected structure including opening crates and conveyance of all accessories from the place of storage to the place of erection to lines and levels including erection of mechanism box checking operation and aligning properly as per the direction of departmental officers.

2

8310

16621.28

... More
Supply of 200 mm dia GI pipe -B class, with coupling, collars, clamps etc complete as per the direction of departmental officers.

20

3000

60000

... More
Removing & Replacing of covering slab of various size without any damage as per the direction of departmental officers

50

101

5085

... More
Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X50 cm at the top with a thickness of 10cm including inscription duly engraved as required.

20

626

12531.8



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.