Kerala State Drugs And Pharmaceuticals Limited Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 19,557Document Cost
₹ 1,847Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_ksdp_668720_1Bid Award Id
ViewTender No
KSDP/PRJ/ELE/HM/19/23-24/224Tender Authority
Kerala State Drugs And Pharmaceuticals Limited ViewPurchaser Address
-Website
http://http://www.ksdp.co.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
2. Illuminaires
-
-
-
Supply and installation of 300W LED Flood light output > 120lumen/W 4000- 6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor >0.95 at full load, internal surge protection up to 10 KV,and Aluminium
pressure die-cast Powder coated housing, acrylic cover complete with THD <10%, power factor >0.98, RoHS compliant, duly wired up for use on 230 V AC supply.
Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip
manufacturer)
8
-
-
Supply of LED-type dom aviation obstruction light with terminal for cable termination and all necessary accessories as required
1
-
-
3. Earthing
-
-
-
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required
1
-
-
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as stripearth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer
etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
2
-
-
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
2
-
-
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.25 mm GI conductor (10 SWG)
20
-
-
4.Switchgears
-
-
-
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
1
-
-
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts,
residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in
the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
1
-
-
Supplying and fixing following rating surge protection device confirms to IEC61643- 11 having protection against direct and indirect lightening surges. Type 1+2, I max 50kA, 3 P+N module
1
-
-
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as
required.Single pole and netural
5
-
-
Supplying, installation, testing and commissioning of Astronomical time switchcapable of following output in feeder pillars/ Lighting DBs for automatic switching
On &OFF of street lights at sun set & sun ruse or twilight override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete ad required3 output (1output per phase) and suitable for three phase supply
1
-
-
Supply and installation of the following accessories suitable for 50Hz, AC supply conforming to IS 8828- 1995/ IEC 60898 of the following current ratings in the existing enclosure and giving connections as required Single dial timer unit analog
type
1
-
-
Supply and installation of the following accessories suitable for 50Hz AC supply conforming to IS 8828- 1995/ IEC 60898 of the following current ratings in the existing enclosure and giving connections as required 4 pole 63 A contactor
1
-
-
5.Cabling
-
-
-
Supply & laying of one number PVC insulated and PVC sheathed armouredaluminium power cable of 1.1KV grade of the following sizes in the existing RCC/HUME / STONE WARE/ GI/ DWC pipe as required.4 core 4 sq mm
50
-
-
Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation63/50 mm or nearest size
20
-
-
Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.5 x4 sq. mm
35
-
-
II.Civil
-
-
-
1.Foundation works
-
-
-
Earth work in excavation by mechanical means (Hydraulic excavator)/manual meansover areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan)
including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposedearth to be levelled and neatly dressed.All kinds of soil
28.88
-
-
Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4coarse sand : 8 graded stone aggregate 40 nominal size)
1.02
-
-
Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
27.2
-
-
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm
nominal size
6.8
-
-
Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
680
-
-
Structural steel work riveted, bolted or welded in built up sections, trusses and framedwork, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
39.56
-
-
Providing and fixing bolts including nuts and washers complete.
51.15
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements