Kerala State Council For Science Technology And Environment Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 16,600Document Cost
₹ 1,568Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_KCSTE_325349_1Bid Award Id
ViewTender No
KFRI/ENGG/INF-002/19-20Tender Authority
Kerala State Council For Science Technology And Environment ViewPurchaser Address
-Website
http://etenders.kerala.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285 fixing with dash fastners of required dia and size including necessay filling up the gaps at junctions ie at top, bottom and sides with required EPDM rubber /neoprene gasket etc. Aluminum sections shall be smooth rust free, straight, mitred and jointed mechanically wherever reqquired including cleat angle, Aluminium snap beading for glazing/ paneling C.P brass/ stainless steel screws all complete as per architechural drawings and the directions of Engineer in charge. (glazing , panelling and dash fastners to be paid for seperately) powder coated aluminium (minimum thichness of powder coating 50 micron)
30
-
-
Providing and fixing panelling in aluminium door, window, ventilator shutters and partitions etc. with 4mm thick aluminium composit panel EPDM rubber / neoprene gasket combosit panel of 4 mm thickness etc. Complete as per direction of Engineer incharge.
20
-
-
Providing and fixing panelling in aluminium door, window, ventilator shutters and partitions etc. with 3mm thick hylam sheet and EPDM rubber / neoprene gasket etc. Complete as per direction of Engineer incharge.
30
-
-
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum moisture resistant board
60
-
-
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. Using equal angles/ M.S flats etc, as per direction of Engineer incharge
545
-
-
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over a steel structure (which will be done and paid seperately) pointing with white cement slurry admixed with pigment of matching shade including rubbing curing and polishing etc. all complete as specified and as directed by the Engineer in charge.
10
-
-
Extra for pre finished nosing to treads of steps of marble stone .
15
-
-
Providing and fixing Thomson Multi wood board or equivalent make paneling 12 mm thick, to frame, backing or studding with screws etc. complete ( Frames, backing or studding to be paid separately) as per the direction of site Engineer-in-charge.
22
-
-
Providing and fixing Thomson Multi wood board or equivalent make paneling 18mm thick, to frame, backing or studding with screws etc. complete ( Frames, backing or studding to be paid separately) as per the direction of site Engineer-in-charge.
22
-
-
Painting two coat with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
35
-
-
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade :One or more coats on old work
100
-
-
Providing and fixing white vitreous china laboratory sink with C.I brackets, C.P. brass chain with rubber plug 40 mm C.P brass waste and 40 mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required: Size 600x450x200 mm
4
-
-
Providing and fixing C.P long body three way lab tap of approved quality conforming to IS standard including all cost of materials and labour charge 15mm nominal bore
4
-
-
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 8931,15 mm nominal bore
4
-
-
Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 31 mm dia of 79 mm length and 62 mm breadth weighing not less than 45 gms
4
-
-
Providing and fixing P.V.C. waste pipe for sink or wash basin including PVC. waste fittings complete. Semi rigid pipe 32 mm dia
4
-
-
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 6Kgf/ cm2- Internal work- Exposed on wall
15
-
-
Wiring for light point/fan point/exhaust fan point/ call bell point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit , with modular switch, modular plate , suitable GI box and earthing the point with 1.5 sq. mm. FRLS PVC insulated copper conducter single core cable etc. are required.
15
-
-
Supply and fixing two module stepped type electronic fan regulater on the existing modular plate & switch box including connection but excluding modular plate etc as required
4
-
-
Supplying and drawing following sizes of FRLS PVC insulated copper coductor, single core cable in the existing surface/recesed PVC conduit as required 3X1.5 sq mm
25
-
-
3X2.5 sq. mm
80
-
-
4X2.5 sq.mm
1
-
-
5X2.5 sq.mm
1
-
-
5X4 sq. mm
30
-
-
3X1.5 sq mm
40
-
-
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
65
-
-
32 mm
20
-
-
Supplying and fixing suitable size GI box with modular plate and cover in front on recess including providing and fixing 6 pin5/6 A 15/16 A modular switch and 15/16 A modular socket, connection etc. as required.
3
-
-
Supplying and fixing following way SP&N sheet steel MCB distribution board 240 volts on surface/ recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator) 8 way double door
1
-
-
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
5
-
-
double pole
1
-
-
Tripple pole
1
-
-
Tripple pole and Neutral
1
-
-
Supplying and fixing single pole blanking plate in the existing existing MCB DB complete etc. as required.
5
-
-
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40A
1
-
-
Supply, conveyance installation testing and commissioning of LED tube light(4 ft) along with driver system wattage mzximum of 20W lumen out put of lamp greater than 1500 lumens, power factor 0.9 rated life of hours 15000 hr,system efficiancy 75 lumen/watt including aii necessary accessories as required complete.
5
-
-
Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required. 1200 mm sweep 5 star rated
1
-
-
Supplying and fixing following modular switch/ socket on the existing modularplate and switch box including connections etc. as required.5/6 A switch
15
-
-
15/16 amp switch
4
-
-
3 pin 5/6 amp socket outlet
15
-
-
Supplying and fixing modular blanking plate on existing modular plate and switch board excluding modular plate as required
2
-
-
6 pin 15/16 amp socket outlet
4
-
-
Telephone socket out let
1
-
-
RJ 45 LAN network socket suitable for UTP CAT6
1
-
-
Supplying and fixing following size /modules GI box along with modular base & cover plate for modular switches in recess as required 2 module
2
-
-
3 module
3
-
-
4 module
6
-
-
6 module
6
-
-
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
1
-
-
providing and laying earth connection from earth electrode with 4.00 mm dia copper wire on surface or in recess for loop earthing as required
15
-
-
supply,installation, testing andcommissioning of 5 star rated 1Tr inverter airconditioner including ODU stand and copper tubing up to 3.5 mtr excluding stabilizer (bluestar/LG/Voltas/Mitzubhashi/equivalent)
2
-
-
supply and drawing UTP CAT6 cable through existing PVC conduit
50
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements