Kerala State Cooperative Federation For Fisheries Development Limited Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 55,100Document Cost
₹ 8,732Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_MFED_458018_1Bid Award Id
ViewTender No
MFED/D1/327/2021Tender Authority
Kerala State Cooperative Federation For Fisheries Development Limited ViewPurchaser Address
-Website
http://etenders.kerala.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
26.31.1 : Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect.SBR Polymer (@10% of cement weight) modified cementitious bond coat @2.2
kg cement per sqm of surface area mixed with specified proportion of approved
polymer
200.43
-
-
... More
26.31.2 : Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect.Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make
200.43
-
-
... More
26.35.1 : Providing and injecting approved grout in proportion recommended by the manufacturer into cracks/honey-comb area of concrete/masonry by suitable gun/pump at required pressure including cutting of nipples after curing etc. complete as per directions of Engineer-in-Charge.br (The payment shall be made on the basis of actual weight of approved grout injected.)Stirrer mixed Acrylic Polymer of approved make @ 2% of weight of cement
used) modified Cement slurry made with non shrink compound in concrete/
RCC work
1062.28
-
-
... More
26.38.1 : Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by Engineer- in-Chargebr Note: Rates shall include the providing necessary ground wires etc. The levelling gauges, if used, shall be paid for separately. Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/tapping with a blunt metal instrument.25mm thick in Grade M 25 with cement content not less than 330 kg per cum
27.63
-
-
... More
26.38.3 : Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by Engineer- in-Chargebr Note: Rates shall include the providing necessary ground wires etc. The levelling gauges, if used, shall be paid for separately. Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/tapping with a blunt metal instrument.75mm thick in Grade M 25 with cement content not less than 330 kg per cum
172.8
-
-
... More
26.40 : Providing and fixing hard drawn steel wire fabric of size 75 x25 mm mesh or
other suitable size wire mesh to be fixed & firmly anchored to the concrete
surface by means of "L" shaped mild steel shear key welded with existing
reinforcement including the cost of materials, labour, tool & plants as approved
by Engineer-in-charge.
200.43
-
-
... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
720
-
-
... More
15.2.2 : Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:4:8 leaner mix ( including equivalent design mix)
31.05
-
-
... More
5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
31.05
-
-
... More
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
200.43
-
-
... More
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
200.43
-
-
... More
14.72 : Providing and fixing double scaffolding system (cup lock type) on the exterior side, upto seven story hight made with 40 mm dia. M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staricase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required location with essential safety features for the workmen etc. complete as per directions and approval of Engineer- in Charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. Note:- This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done .
760
-
-
... More
Part B roofing
-
-
-
... More
od201637/2021_2022 : Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking the material within 50 metres lead and reusing the same after repairs to the valley :<br>Asbestos Sheet
1264
-
-
... More
12.8 : Providing non- asbestos high impact Polypropylene reinforced cement 6 mm thick corrugated sheets (as per IS: 14871) roofing up to any pitch and fixing with polymer coated J or L hooks, bolts and nuts, 8 mm dia G.I. plain and bitumen washers or with self drilling fastener and EPDM washers etc. complete (excluding the cost of purlins, rafter and trusses), including cutting sheets to size and shape wherever required.
63.2
-
-
... More
od200878/2021_2022 : Providing ISO Build 50mm thick EPS both side GI. coated sheet (one side 0.5 mm thick sheet and other side 0.4 mm thick sheet) for Ceiling with necessary hanging arrangements like angles, channels, silicon sealant etc complete.
274.4
-
-
... More
od200879/2021_2022 : Supplying and fixing S.S pathy made of 304 grade S.S sheet of size 5' x 10' 20 guage with approximate weight not less than 36 kg/ sheet. The sheet will be bend to required shape as directed by the engineer in charge. Necessary overlaps will be provided of not less than 10 cm. Necessary welding will be done for filling the joints. Providing down pipes of 10" dia at a distance of 10 m c/c. As directed by the officers of Matsyafed.
316
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements