Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 46,000Document Cost
₹ 2,360Tender Fee
Refer Documents
Summary
Retender For Renovation And Reconstruction Of Chavara Branch Building
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_KSCB_586359_2Bid Award Id
ViewTender No
KSCB/R1/KLM/GAD/E-T/2023-24/1Tender Authority
The Kerala State Cooperative Bank Limited ViewPurchaser Address
-Website
http://etenders.kerala.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
RETENDER NOTICE FOR RENOVATION AND RECONSTRUCTION OF CHAVARA BRANCH BUILDING
BOQ Items
b. Exterior: Painting exterior wall with weather proof paint over one coat of cement primer after dusting and cleaning the surface
284
-
-
TERRA COTTA JALI TILES (For Elevation) - Jali tiles of camp jail design. Rate to include supporting frame work, jointing material, labour etc complete.
16
-
-
STAIR - Providing MS steel open riser stair, with wooden treads and SS handrails.
7
-
-
STRUCTURAL STEEL FLOOR - Providing and fixing MS steel joist floor with main universal beam, purlins with secondary C sections, the spacing of floor joist can be 30-40cms. Rate excluding flooring.
20
-
-
COMPOSITE FLOOR/DECK SHEET CONCRETING - Providing deck sheet concrete roof at first floor roof level.
3
-
-
VERTIFIED TILES - Providing & laying flooring with Full Body Vitrified Tiles (Double Charged) of approved make, shade and colour of 800mm x 800mm size of 10 / 12mm thickness laid over laid over a flooring bed of 50mm to 75mm thick or more in CM 1:8 proportion including neat cement slurry of honey like consistency spread at the rate of 3.3 Kgs cement per Sq.M. before laying tiles on base coat and filling the joints with white cement or colour cement to match the shade of tiles including cost of base coat, cement slurry, jointing material and cost and conveyance of all materials viz., cement, sand, water, vitrified tiles, white or coloured cement etc., to site, labour charges for all operations etc., complete as directed, curing etc., complete for finished item of work. Alternatively approved make Tile adhesive and jointing compound can be used without any extra cost. (Base Rate Excluding GST for body tiles - 700/Sq.M. and Base rate for dark tiles - 800/Sq.M.).
183.62
-
-
FLOOR TILES FOR WASHROOM - Anti skid ceramic tiles for washroom floor.
13.5
-
-
WALL TILES FOR WASHROOM - Ceramic wall tiles for washroom walls.
42
-
-
DECK FLOORING - Deck flooring for the new structural steel floor. Providing WPC deck flooring on the steel floor after fixing 38mm particle board. Rate to include all necessary fittings etc complete.
19.55
-
-
COLLAPSIBLE SHUTTER - Providing and fixing mild steel collapsible shutter gate in front of the main door. Rate to include all necessary fittings etc complete
9.6
-
-
ROLLING SHUTTERS - Providing and fixing 18 gauge galvanised steel rolling shutters including all necessary fittings etc complete
12
-
-
BRICK MASONARY WALLS - Brick Masonary/ Cement blocks in cement mortar 1:6 and of standard specification including cost of material and labour. The surface shall be made wet by water before use with all necessary projections, splays cutting, circular moulding, corbelling etc as per drawings. including cost,conveyance, all taxes, royalties, loading and unloading of
all materials, including cost of all labour, scaffolding,watering and curing, sundries, etc. complete as per the direction of the Engineer-in-charge.
15
-
-
PLASTERING - Plastering with cement mortar 1:4, 12mm thick 1 coat on internal and external surfaces of walls at all heights, floated hard and trowelled to get a smooth finish. The rate shall include scaffolding, curing etc complete.
76
-
-
TOILET WALL PARTITION - Wall partitions with support system mentioned in 12 (a), and fixing interior grade HPL (8mm) both sides. Color / design shall be approved by the Architect in charge.
23
-
-
REUSE WINDOWS - Reusing the existing window frames of size 1.5m x 1.5m on the newly constructed wall on the east side. Rate for shutters to be included if it is found that the existing shutters cannot be used.
2
-
-
VENTILATION FOR STAIRS AND TOILETS - Supply and fixing Aluminium framed glazed windows using 8mm thick toughened glass for panels including all fittings, window bars etc shall correspond to IS designation HE 9 WP of IS 733. Hollow aluminium alloy sections used shall conform to IS designation HV9WP of IS 1285. Machine screws used shall conform to the requirements of IS 1362. Also cadmium plated screw, nuts, washers, bolts lugs of steel shall be used on direction of the Employer/ Architect. Ventilator shall have openable/ sliding shutters. Rate inclusive of fittings etc complete. Toilet ventilators also included.
3.8
-
-
PLUMBING WATER CLOSET - Supplying and fixing one piece European Water Closet white glazed with flexible trap way, Slow Motion Seat Cover etc complete for finished item of work for all floors. (67cm x 37cm x 73cm, White)
3
-
-
WASH BASINS -
Supply & fixing table top and wall mounted wash basins with waste plug &
chain, pillar tap, flexible hose, angle valve,
PVC trap etc. (all items of approved quality)
including connection to water supply system
and drainage system.
a. TABLE TOP : 48 × 37 × 13 cm Ceramic- glossy (2 No’s)
2
-
-
b. WALL HUNG : 42 x 29.5 x 12.5cm/Ceramic -Glossy Finish(3 Nos)
3
-
-
FLOOR DRAINS Supply & fix stainless steel floor drains with lid including trap etc. Size 6x6 inches in 304-Grade stainless steel having 18% Chromium and 8% Nickel composition for non-corrosive and rust-resistant qualities.
3
-
-
Supplying and fixing Chromium plated
finish brass body quarter turn Bibcock cumHealth Faucet with 1m long tube and wall hook with 7 - 10 years warranty with necessary fittings etc., complete includingcost and conveyance of all materials, labour charges, overheads & contractor profit complete for finished item of work in all floors.
3
-
-
Supply and fix soap dispenser(chrome finish) wall mounted etc. (all items of Approved quality).
5
-
-
Supply and fixing of SS toilet paper holders. With max. length 12cm, square type in black matt finish.
3
-
-
SUPPLY AND FIX TOWEL ROD - a. 155mm Diameter chrome finish(2 No’s) :
2
-
-
b.60cm Single Towel Bar In Chrome Finish(3Nos) :
3
-
-
Allow for all internal plumbing work for watersupply, waste water and sewerage including supplying and fixing pvc pipes accessories,valves, traps etc. braking and making good block work, concrete for making recesses to fix pipes , making man holes.
1
-
-
Supply and fixing single drain stainless steel kitchen sink, sink tap, waste plug & chain, flexible hose angle valve etc complete
1
-
-
SUPPLY AND FIXING MIRRORS - a. 600 x 450 mm.(2 No’s) frameless with beveled edges :
2
-
-
b. 0.5mm mirrors (0.81m2) Complete with all fittings :
0.81
-
-
EXTERNAL DRAINAGE - Allow for external drainage work including construction of man holes, supplying and fixing drainage pipes etc. system.
1
-
-
SEPTIC TANK - Supply and fix Hycount/any approved septic tank and soakage pit including all connections to the sewerage system. Approximate size 60cm x240cm(700ltrs).
1
-
-
LADDER FOR ROOF - Providing exterior aluminum fixed ladder for accessing the top most floor with cages and rest platforms for each 30 feet of height. Sections shall be painted or powder coated. Tread to be 45-60cm,rungs at equal spacing of 30cms, with 3/16’’ aluminum brackets fixed on floor brackets of size 4’’ x1 3/8’’ x 3/16’’ Rate to include all fittings, painting etc complete.
1
-
-
DEMOLISHING OF EXISTING WALLS/SLAB - Demolition of existing walls/slab: Demolition of existing walls, cutting of RCC slabs and using part / full of the foresaid for raising the GF floor level and removing the same from site if required. a. existing walls :
80
-
-
b . RCC slab :
15
-
-
INTERIOR WORKS
-
-
-
TRANSACTION CABIN - Providing, making and placing in position worktables made in 18mm MDF Exterior Grade Board for all members with Foot Rest, Key Board Tray and vertical supports at approximately every 1350mm length. The Work Table top to have 1mm Laminate as specified and all round front facia to have 12mm thick MDF Exterior Board lipping with all exposed faces to have 1mm Glossy Laminate as specified. The unexposed surfaces of MDF Exterior Grade members to have NO VOC or LOW VOC duco paint finish or 0.8mm Laminate OR minimum three coats of LOW VOC or NO VOC enamel paint with putty etc., complete as directed. The table to have drawer units as per drawing. The cost to include all materials, labour, necessary hardware viz., drawer channels, " W " hinges, SS handles, set locks etc., to a neat job as per directions etc., complete. Providing and fixing 75cm high Bank Counters. The counters(3No’s)shall be L shaped (1.65 x.75m , 0.45x0.45m).A space of 60cms is provided as computer area and 15cms as customer area. Each counter shall have drawers, cupboards, CPU stand, key board tray and wire manager. Drawers to have drawer slides (Heavy duty type) metal body locks and all required hardware. Sufficient leg space shall also be provided. Locks, handles sliders, auto closures are also to be provided. Counter to be in the shape as per the plan. TOTAL AREA: 220sq.ft
Rate inclusive of all works.
3
-
-
CASH COUNTER - Providing cash counter L shaped (1.95x0.90m,0.90x0.45m)with a customer height of 110cm in 18mm MDF Exterior Grade Board for all members. The counter shall have a 15cm wide top as customer writing area.A 12mm thick toughened glass is provided on the counter(vertically) having a height of 64cm and width of 190cms. The glass shall be fixed on two wooden posts made out of BWR Ply. The counter shall be provided with drawers, cupboard arrangement with sliders, rack for CPU, using Ebco Zinc Channels. Safe locking arrangements withj Lock, Handle etc shall be provided.The12mm thick glass shall be fixed in the post, as per the specification and direction of the engineer in charge. The front and visible surfaces shall be laminated using 1mm thick laminate. All the unexposed faces to have 0.8mm Laminate OR minimum two coats of NO VOC or LOW VOC enamel paint with putty finish. All other members to be with 18mm MDF Exterior Grade Board and all exposed faces of the table to have 1mm Laminate OR 1mm Glossy Laminate OR 12mm thick MDF Exterior Grade Board finished with minimum two coats of LOW VOC or NOW VOC duco paint as specified to be used. TOTAL AREA: 102 sq.ft.
1
-
-
SHELVES - Shelves shall be made in18mm MDF Exterior Grade Board. All other exposed faces of the unit to have 1mm Glossy Laminate as specified and all unexposed faces to have 0.8mm Laminate OR NO VOC or LOW VOC enamel painting with putty finish on all unexposed faces including NO VOC or NO VOC duco paint finish for all other exposed surfaces of MDF Exterior Grade members and all necessary hardware viz., 'W' or wing hinges, locks, handles, tower bolts etc., and MDF Exterior Grade beading 36mm x 36mm at top and MDF Exterior Grade edge lipping 18mm x 12mm etc., as per drawings and directions etc., complete. 1.OVER HEAD UNIT : over head cabinet shall have be at height of 1.5m from the FFL. The maximum reachable height shall be 2.10m.
Amenities room - 2.75 mx0.45x0.60m(1No’s, with two sliding doors),
2. COUNTER TOP WITH STORAGE BELOW: A countertop with storage shall be provided in amenities room made in 18mm MDF Exterior Grade Board to all members except counter top and 25mm block board for countertop. Racks shall be provided in the same.
Size- 1.55mx0.60x0.90m(1No’s, with two shutters),
3.FULL HEIGHT SHELVES :full height shelves with four sliding doors shall be provided in the banking hall. Rate to include all fittings including channels, locking system, hinges, handles etc complete
4.20m x 0.45 x 2.10m(1No’s),with four sliding doors.
4. FULL HEIGHT SHELVES: full height shelves with two shutters shall be provided in the store room area.
1.65m x 0.60 x 2.10m(1No’s),
5.FULL HEIGHT SHELVES :full height shelves with two shutters.
1.50m x 0.60 x 2.10m(1No’s),
6.Open rack : 1.52m x0.45mx2.1m(1No’s), with two partitions.
7. 1.20m x0.45mx2.1m(1No’s) : full height shelves with two shutters.
6
-
-
MANAGER TABLE - L shaped Table having a length of 195cm (width 90cm)to one side and length of 0.30m (width 45cm ) to the other side made in 18mm MDF Exterior Grade Board for all members except table top and 25mm block board for table top with Foot Rest, Key Board Tray and vertical supports at approximately every 1350mm length. The table has a height of 75cm. The top shall be provided with 8mm toughened glass.
The table shall be provided with drawers & cabinet units made out of 18mm MDF Exterior Grade Board .
Locks, handles, space for CPU and sufficient leg space shall also be provided.
All the unexposed faces to have 0.8mm Laminate OR minimum two coats of NO VOC or LOW VOC enamel paint with putty finish. All other members to be with 18mm MDF Exterior Grade Board and all exposed faces of the table to have 1mm Glossy Laminate OR 12mm thick MDF Exterior Grade Board finished with minimum two coats of LOW VOC or NOW VOC duco paint as specified to be used. TOTAL AREA: 55sq.ft.
Glass area :21.sqft
1
-
-
ASST.MANAGER TABLE - Table having a length of 180cm x75cm made in 18mm MDF Exterior Grade Board for all members except table top and 25mm block board for table top with Foot Rest, Key Board Tray and vertical supports at approximately every 1350mm length. The table has a height of 75cm. The top shall be provided with 8mm toughened glass.
The table shall be provided with drawers & cabinet units made out of 18mm MDF Exterior Grade Board .
Brass locks, handles, space for CPU and sufficient leg space shall also be provided.
All the unexposed faces to have 0.8mm Laminate OR minimum two coats of NO VOC or LOW VOC enamel paint with putty finish. All other members to be with 18mm MDF Exterior Grade Board and all exposed faces of the table to have 1mm Glossy Laminate OR 12mm thick MDF Exterior Grade Board finished with minimum two coats of LOW VOC or NOW VOC duco paint as specified to be used. TOTAL AREA: 40sq.ft.
Glass area :15sqft
1
-
-
GLASS SEPERATION - Providing, making and fixing in position 12mm thick toughened clear float glass in the front side of half height partitions of Asst.Manager of approximate size 176cm x 30cm .All the edges of the glass to be polished for a smooth finish and the glass is to be fixed with " D " brackets. The cost to include all materials, labour, hardware etc., for a neat finished job as per drawings and directions etc., complete.
1
-
-
TABLES - Table having a length of 150-180cm x75cm made in 18mm MDF Exterior Grade Board for all members except table top and 25mm block board for table top with Foot Rest, Key Board Tray etc complete. The table has a height of 75cm. The table shall be provided with drawers & cabinet units made out of 18mm MDF Exterior Grade Board. Brass locks, handles, space for CPU and sufficient leg space shall also be provided.
Rest of the spec to be followed as earlier items.
1
-
-
FIXED GLASS WORKS (MAIN ENTRANCE AND GLASS PARTITION WITH 12MM TOUGHENED GLASS WORK ) - Providing, making and fixing in position Fixed 12mm toughened glass as fixed glass from Floor to available Ceiling level along with Main Entrance Door and for Partitions. The glass is to be fixed with patch fittings and all the edges of the glass have to be polished for a smooth finish. The work includes cost of all materials, etching/ logo,approved hardware, making necessary template before toughening of glass and fixing the same as per site conditions to a neat finished work as per drawings and directions etc., complete.
10.5
-
-
GLASS DOOR - Providing, making and fixing in position Fixed 12mm toughened glass openable shutters work as per specifications given below and for the openings mentioned. Main Entrance Glass Work comprising of Door opening of approximate size 1200mm x 2250mm - 2400mm and Partition Doors of approximate size 900 - 1000mm x 2250mm - 2400mm. The entire work to be done as per site conditions.
Etching the glass with bank logo/
frosted design with necessary sand blasting/granular blasting to
be provided and edge should be machine beveled polished
glass
(a) Entrance door + Other glass doors- Providing, fixing in position glazed entrance door and other doors with patch fitting or approved make (Door approx. Size: 1200mm - 1500mm x 2400mm - 2250mm and Single Door approx. Size: 1000mm - 12mm x 2400mm - 2250mm) using 12mm / 10mm toughened glass edge polished. The Door to consist of Heavy Duty Floor spring, Upper Patch, Bottom Patch, Lock Keeper Plate, Euro Profile Cylinder (EPC), "H" Type Handle 32 x 600mm, Corner Lock and the side fixed glass to have 2 Nos. Bottom Patch and 2 Nos. Upper Patch for each door to a neat finish etc., complete as per drawing. (b) The work includes cost of all materials, approved hardware, making necessary template before toughening of glass and fixing the same as per site conditions to a neat finished work as per drawings and directions etc., complete. (5Nos+1 Slidig door)
14.6
-
-
THICK DOORS - (2 NOS) Providing and fixing 35mm thick solid core flush shutter for cash cabin and ATM UPS room with 85mm x 18mm MDF Exterior Grade jamb all round and 12mm x 12mm MDF Exterior Grade button beading fixed 1mm Laminate as specified on both sides and 8mm clear float glass with etching with 50mm x 18mm MDF Exterior Grade jamb around the glass opening and 12mm x 12mm MDF Exterior Grade beading for fixing of glass on both sides. The rate to include necessary hardware viz., door stopper, door buffer, pair of " H " type handles, Mortise Dead Lock and Euro Profile Cylinder - Key and Knob 70mm SS, 4 Nos. SS 2 ball-bearing hinges - (127mm x 76mm x 2.5mm), door closer (all of approved make and quality), etc., complete as directed.
3.4
-
-
TOILET DOOR - (3 NOS) Supply and fixing PVC door with all necessary fittings.
5.04
-
-
LACQUERED GLASS - Providing and fixing in position 12mm toughened lacquered glass (colour - Black ) for glass partition. The work to include making necessary template for all the glasses and then cutting the glass to correct size, making all the necessary holes, cuts etc., and then toughening the same. The cost to include all hardware required viz., single corner patch; bracket etc., The approximate size of each glass will be 450mm x 2300mm to 1200mm as per site conditions. The rate is for a finished item of work etc., complete as directed and should also include tracks or channels at doors openings. Sliding Door area: 1.90sq.m.
7.5
-
-
FULL HT PARTITION - Providing and fixing metal stud dry wall partition with following specifications: The Partition will be fully opaque, partly opaque and partly glazed as per specific site conditions and drawings. (a) Supporting system comprising of 51mm / 50mm x 35mm / 34mm x 0.5mm metal studs at 600mm c/c and 51mm / 50mm x 32mm x 0.5mm metal tracks at floor, middle, door and ceiling level with joints staggered to avoid through joints. The vertical members should touch the ceiling with horizontal ceiling channel at slab / beam bottom. The rate should also include necessary strengthening with studs / tracks or channels at doors and other openings. (b) 12mm MDF Exterior Grade Board fixed on both sides with 25mm dry wall screws for the entire height of the partition. Partition to have 8mm clear float glass fixed with 85mm x 18mm alround MDF Exterior Grade jamb and 12mm x 12mm MDF Exterior Grade button beading on both sides of the glass, to a neat finish as per drawings and directions etc., complete. Partition above 2350mm level to have NO VOC or LOW VOC plastic emulsion paint finish on both sides.
All exposed surfaces of MDF Exterior Grade members to have minimum two coats of LOW VOC or NO VOC duco paint finish. All sections used should adhere to the manufacturer’s guidelines and the contractor has to submit certificate from the manufacturer on usage of their specified sections. Partition measurement will be considered from floor level to false ceiling level.
55
-
-
HALF HT PARTITION - Same as item above, but for height of 1100-1500mm from finished floor level, to a neat finish as per drawings and directions etc., complete and the following: Rate for fixing of glass already included in item no :06
The cost to include all materials and hardware required etc., as per site conditions. The rate is for a finished item of work etc., complete as directed. Areas include Asst manager’s half partition, rear of store and staff entry partition.
6.5
-
-
FALSE CEILING WORKS(Required for Banking Area Only) - Providing ceiling work using Saint Gobain Gyproc Company’s Gypsum Board 12.5mm thick fixed to ceiling Frame Work of Gyroc – True steelat a height of 255-275cm from finished floor level – out of the following material including finishing with jointing compound, paper tape, one coat of primer and two coats of approved quality and shade plastic emulsion paint as per approved samples complete including preparing the surface etc. The 12.5mm thick gypboard fixed to the metal frame as per the conditions. Ceiling channel (MF5) 80mmx26mmx0.5mm at equal spacing centre to centre. Intermediate channel (MF7) l5mmx45mmx0.9mm at every 1220 mm centre to centre.
Perimeter channel (MF6A) 20mmx27m all along the wall. Strap hanger (MF8) on suspending the framework 25mmx0.5mm
with nuts and bolts (P526) 6.4mmxl2.7mm Connecting clip (MF9) 2.63mm Dry wall screws 25mm long Dash fastener/raw plug 12.5mm dia.x35mm long with 6mm dia.bolt.
Soffit clip 27mmx37mmx1.6mm thick All as per manufacturer's specification including all fixtures and fastenings complete.
The ceiling at the central portion shall have dropsat certain levels. Necessary cut-outs to be given wherever required for light fittings.
Finishing false ceiling with two or more coats of plastic emulsion paint (super white color) to give an even shade.
Design shall be done as per instruction of the architect.
(No separate measurements will be considered for the vertical up to 300mm height surfaces and cove lighting areas only plan area will be considered for the measurements ) Further the rates to include cutouts for lighting fixtures / AC grilles / Fire Alarm Detectors if any etc., along with necessary strengthening and supports for fixing of these.
90
-
-
PANELLING WORKS - Encasing to columns/wall in the banking hall where ever shown in drawings out
of framework of 50 mm X 25 mm - 18 gauge section unannodised Aluminium ( as per requirement) frame work @ 16”
to 24” c/c vertically & horizontally. The frame work to be clad with 8.0 mm thick commercial ply , 1mm thick laminate and following finishes as per drawing and instructions. Column Paneling above 2350mm level to have NO VOC or LOW VOC plastic emulsion paint finish on all four sides as shown in drawing.
28.6
-
-
B.Paneling finished with 12.0 mm thk. back lit solid surface for walls :
Making and fixing in position (as per approved sample) LaserCut / CNC cutting back lit solid surface to be made to design with frame work as mentioned above and all kind of coves & provisions of LED lights. The rate should be inclusive of making Coves for LED / lighting / opening with
frame etc.
9.66
-
-
WRITING DESK - Supplying and fixing writing platform for customers, wall hung with all necessary brackets, etc complete in 12mm thick BWR ply, and finishing the surfaces with 1mm thick laminate.
0.35
-
-
BLINDS - Providing and fixing in position of Roller Blinds of approved Fabric (Fabric Cost - RS. 1,000/- per Meter) of Hunter Douglas / Mac / Vista make or approved equivalent of approved shade etc., as directed. (Window opening to be considered for measurement)
5
-
-
LOGO - Providing KSCB Logo 1500mm diameter made with 6mm acrylic sheet with provision for back lighting as per directions etc., complete for outside.
1
-
-
ELECTRICAL WORKS
-
-
-
METER BOX WITH SERVICE PIPE - Supply and fixing 3-Phase meter box ( Out door type IP - 65) with 3 Nos 40 A bakelite fuse unit with suitable size of HRC fuses,63 A Neutral link,63Amps 4 Pole MCB and service pipe extra complete. Supply & Erection :
1
-
-
DISTRIBUTION BOARDS AND CIRCUIT BREAKERS - Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required. a. 6 Way VTPN MCB DB (MAIN) Supply & Erection :
1
-
-
Supplying and fixing of following ways surface/ recess mounting, horizontal type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required. a. 6 Way TPN MCB DB(PDB,LDB) Supply & Erection :
2
-
-
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) a. 12 Way SPN MCB DB(UPS DB)(FLOOR,ATM) Supply & Erection :
2
-
-
Providing and fixing following rating and breaking capacity and pole RCCB in existing Cubicle panelboard(RCCB+MCB) a. 4P 40A 100mA Sensitivity Supply & Erection :
1
-
-
b. 4P 32A 30mA Sensitivity Supply & Erection :
1
-
-
c. 2P 25A 30mA Sensitivity Supply & Erection :
2
-
-
Supply and fixing of following rating 10kA MCB as required a.25A to 40A TP MCB Supply & Erection :
5
-
-
b.6A to 32A SP MCB Supply & Erection :
42
-
-
c.63A 4P MCB Isolator Supply & Erection :
1
-
-
d.40A 4P MCB Isolator Supply & Erection :
1
-
-
e.25A DP MCB Isolator Supply & Erection :
2
-
-
CABLES - Supply, Laying, testing and commissioning of the following PVC /XLPE Insulated Armoured Aluminum L.T. Cables(AYWY/AYFY) through excavated trenches, built up cable trenches, cable trays, hume pipes, including supply and fixing of clamps, nuts and bolts, screws, identification tags, route markers etc. required for clamping intervals as necessary a.3.5Cx 35 Sq.mm UG Cable :
1
-
-
b.4Cx 25 Sq.mm UG Cable :
1
-
-
c.4Cx 16 Sq.mm UG Cable :
140
-
-
d.4Cx 10 Sq.mm UG Cable :
40
-
-
e.2Cx 10Sq.mm UG Cable :
60
-
-
f.8Cx 1.5 Sq.mm Copper Cable :
20
-
-
CABLE TERMINATION - Supply of all materials and termination of the following PVC Insulated Armoured Aluminum L.T. Cables (AYWY/AYFY) using single compression type cadmium plated brass cable glands, Copper crimped type cable lugs cable identification tags and including gland earthing using copper conductor of adequate size, AL-CU strip for termination of cables etc. a.3.5Cx 35 Sq.mm UG Cable :
1
-
-
b.4Cx 25 Sq.mm UG Cable :
1
-
-
c.4Cx 16 Sq.mm UG Cable :
10
-
-
d.4Cx 10 Sq.mm UG Cable :
2
-
-
e.2Cx 10Sq.mm UG Cable :
4
-
-
f.8Cx 1.5 Sq.mm Copper Cable :
2
-
-
PIPE EARTH STATION - Supply of all material & providing pipe earth station with 2500mm long, 38mm Diameter G.I. pipe, earthing strips, clamps, funnel, terminal Electrodes etc., excavation in all classes of soil, filling with alternate layers of charcol and salt and back filling, construction of Earthpit Inspection Chamber. The Earthing Station should conform to IS 3043/1987.
4
-
-
EARTHING CONDUCTORS - Supply & Laying, clamping at site of copper earthing conductors inclusive of providing earthing terminations and bracing of the terminations etc. a.6 SWG Copper wire :
1
-
-
b.10 SWG Copper wire. :
140
-
-
c.25 x 3 Copper wire :
15
-
-
DOCUMENTS AND APPROVALS(ONLY FOR KSEB) - Preparation of necessary documents, forms, drawings, schemes, certificates, etc., and getting approval from KSEB for the installation. Miscellaneous charges will be paid by the client. Documentation works and Service Charges :
1
-
-
POINT WIRING USING MODULAR SWITCH SOCKETS - Supply and Labour charges for point wiring for 230 volts A.C. Circuits through PVC conduits, 1.5 Sq.mm single core PVC insulated copper wire , 6A control switches, 6A sockets, MS mounting boxes etc. as necessary for the following items.The wiring should be done over the surface/open/concealed type with modular switches & Sockets.Total distance from switch to point shall not exceed 5 meters.Incase if the length increases above 5 meter, additional length shall be measured under item no.12.1 a. 1 No. light/Wall Fan/Exhaust Fan point controlled by 1 No. 6A SP switch. Supply & Labour charges :
40
-
-
b.Group controlled light point for controlling additional light points using same switch. Supply & Labour charges :
15
-
-
c.1 Nos. light points controlled by 2 No 6A, two way Switch. (Two way Control) Supply & Labour charges :
2
-
-
1 Nos. Ceiling fan point along with 1 no 250W Electronic fan regulator,controlled by 1No 6A SP Switch. Supply & Labour charges :
1
-
-
1 No. 6A Socket outlet controlled by 1 No. 6A SP switch in combined position. Supply & Labour charges :
12
-
-
1 No. 6A Socket outlet controlled by 1 No. 6A SP switch in independent position.(Excluding Circuit wiring) Supply & Labour charges :
15
-
-
2 Nos. 6Amps Socket outlet contrelled by 2 No. 6 Amps SP Switch for computer. (Excluding Circuit wiring)Supply & Labour charges :
9
-
-
1 No. 16A Socket outlet controlled by 1 No. 16A SP switch in independent position .(Excluding Circuit wiring) Supply & Labour charges :
5
-
-
1 No. 20A DP Switch in independent position for Motors and A/C points .(Excluding Circuit wiring) Supply & Labour charges :
5
-
-
Supply and providing plug and socket(2P+E) with 25A DP MCB for ups.(Excluding Circuit wiring) Supply & Labour charges :
1
-
-
Supply and providing controll box having timer and contactor for atm A/C points.(Excluding Circuit wiring) Supply & Labour charges :
1
-
-
WIRING - COPPER WIRES - Supply and Labour charges for laying and Termination of PVC Insulated copper wires through PVC conduits for the following types of wires a.Circuit wiring using two runs of 1.5 Sq.mm PVC insulated copper wires along with one run of 1.5 Sqmm Wire continuous earthing, through PVC conduit. Supply & Labour charges :
150
-
-
b.Power point wiring using two runs of 2.5 Sq.mm PVC insulated copper wires alongwith one run of 1.5Sqmm Wire continuous earthing, through PVC conduit. Supply & Labour charges :
600
-
-
c.Power point wiring using two runs of 4 Sq.mm PVC insulated copper wires alongwith one run of 2.5Sqmm Wire continuous earthing, through PVC conduit. Supply & Labour charges :
200
-
-
d.Power point wiring using 4 runs of 6 Sq.mm PVC wire through PVC conduit.for DB Circuit. Supply & Labour charges :
15
-
-
LIGHT FIXTURES & FAN FITTINGS Supply &Labour charges for, fixing, testing and commissioning on roof/truss/ceiling/wall of the following light fixtures/fans with all necessary ball and sockets, rackets, down rods and 3-core flexible wires etc. a.1x18W LED Tube Light Fixture Supply&Fitting charges :
6
-
-
b.Wall Light Fixture EXTERIOR Supply&Fitting charges :
6
-
-
c.1x11W Mirror Light Fixture Supply&Fitting charges :
2
-
-
d.12W Surface Mounted Light Fixture Supply&Fitting charges :
24
-
-
e.Hanging Light Fixture Supply&Fitting charges :
3
-
-
f.Focus Light Fixture Supply&Fitting charges :
2
-
-
g.Concealed Linear light Fixture Supply&Fitting charges :
15
-
-
h.LED Strip Supply&Fitting charges :
15
-
-
i.7W COB Light Fixture Supply&Fitting charges :
6
-
-
j.250mm Sweep Wall Fan Supply&Fitting charges :
6
-
-
k.250mm Exhaust Fan Supply&Fitting charges :
3
-
-
l.1200mm Ceiling Fan Supply&Fitting charges :
8
-
-
m.Wall Lamp Supply&Fitting charges :
4
-
-
TELEPHONE WIRING - a. Supply and wiring of Telephone socket using telephone wire upto the Terminal connector including conduits. 2 Pair Telephone Cable Supply and labour charges :
100
-
-
b.Supply and fixing Telephone socket (RJ11) with faceplate, box etc. Supply and labour charges :
4
-
-
c.Supply and fixing 10 pair crone connector box with crone modules includining necessary termination Supply and labour charges :
1
-
-
DATA - a.Supply and laying of CAT 6 UTP cable in conduit /PVC truncking with all accessories etc. as required. Supply and labour charges :
300
-
-
b.Supply and fixing of CAT6 RJ45 with I/O Computer Jack with faceplate and all required accessories, connection etc.as required. Supply and labour charges :
12
-
-
c.Supply and Installation of 6U network rack ,24 port patch panel,and suitable cable manager with cover and PDU. Supply and labour charges :
1
-
-
d.Supply, installation, testing and commissioning of Patch cords (1m)
9
-
-
e.Supply, installation, testing and commissioning of Patch cords (2m)
9
-
-
f.Supply, installation, testing and commissioning of 24 port gigabite managable network switch with 2 SFP port
1
-
-
CCTV / CAMERA - a.Supply and laying CAT 6 cable through pvc conduit with required accessories as required
650
-
-
b.Supply and fixing 5MP IP bullet camera with night vision,poe, with audio accessories as required
5
-
-
c.Supply and fixing 5MP IP dome camera with night vision,poe with audio, accessories as required
8
-
-
d.Supply and fixing 16 channel NVR H.265 compression with 30 days storage, real time recording with accessories as required
1
-
-
e.Supply and fixing of CAT6 RJ45 Jack with all required accessories, connection etc.as required.
26
-
-
f.Supply, installation, testing and commissioning of Patch cords (1m)
13
-
-
g.Supply and fixing 9U rack for cctv system with all accessories as required
1
-
-
h.Supply and fixing 4TB hard disk with accessories as required
1
-
-
i.Supply and fixing of 16port poe switch accessories as required
1
-
-
AC UNITS a.1 Ton, 3 Star Inverter Ac
2
-
-
b.1.5 Ton 3 Star Inverter Ac
3
-
-
TRUSS ROOFING WORKS
-
-
-
Dismantling of existing truss roof and providing a new truss roof - a. Dismantling roofing including ridges, hips, valleys,gutters etc., and stacking the same.(AREA : 37sq.m) :
1
-
-
b. Steel work in GI/MS tubular (square or rectangular hollow tubes etc.) trusses matching existing profile; including cutting, hoisting, fixing in position and applying two coats of approved epoxy primer and two coats of epoxy paint, including welding and bolted with special shaped washers etc. complete. Providing pre painted galvalume roofing sheet including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers,complete (up to any pitch in horizontal/ vertical or curved surfaces), and including cutting to size and shape wherever required for 0.80mm thick roofing sheet.
189
-
-