Kerala State Construction Corporation Limited Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kerala State Construction Corporation Limited - KSCC Tender

Works
Civil And Construction
Eprocure
Opening Date20 Dec 2024
Closing Date3 Jan 2025
Tender Amount₹ 23,90,999 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

144

-

-

... More
OD197195/2024-2025:Supply and laying of 6.0 Sq.mm Photo Voltaic Solar cables with a nominal DC voltage of a 1.5kV designed to withstand the demanding environmental conditions that arise in any fixed, mobile, roof or architecturally integrated photovoltaic installation through the existing conduits etc. with all necessary accessories. The cable shall have the specifications of Conductor Class 5, Flexible Electrolytic Tinned fine copper strands according to IEC 60228, Insulation Crosslinked Halogen Free and Flame Retardant, Outer Sheath Crosslinked Halogen Free and Flame Retardant UV, Ozone Resistant Sheath, Rated DC Voltage 1.5kV, Maximum Permitted DC Voltage 1.8kV, Maximum Permitted AC Voltage 1kV, Spark Test 6000Vac (8400Vdc), Voltage Withstand 6.5kV ac and 15kV dc, Ambient Temperature -40 Deg.C ~ +90 Deg.C, Maximum Temperature of Conductor 120 Deg.C (20000h), Short Circuit Temperature 200 Deg.C (at conductor max. 5sec), Thermal Endurance Test According to EN 60216-2 (temperature index +120 Deg.C), Mineral Oil Resistance according to EN 60811-2- 1, Ozone Resistance according to EN 50396 part 8.1.3 Method B, Acid and Alkaline Resistance According to EN 60811-2-1 (Oxal acid and sodium hydroxide), Weathering-UV Resistance, Single Cable Flame Test EN 60332-1-2, Low Smoke Emission EN 61034-2 (Light Transmittance greater than 70%), Halogen-free per EN 50525-1 Annexure B, Tensile Strength 6.5 N/mm2 for insulation and 8 N/mm2 for sheathing according to EN60811, Elongation of Insulation and sheathing 125% according to EN60811, Shrinkage 2% at 120 Deg.C according to EN 60811-1-3 etc. complete as required

200

-

-

... More
OD197213/2024-2025:Supply, installation, testing and commissioning of 1 Pair of high quality MC4 Photovoltaic Module Connectors used for low-voltage DC applications up to 1500V, conforming to IEC 62852:2014 (Connectors for DC Application in photovoltaic systems - Safety requirements and tests) etc. complete as required

15

-

-

... More
OD197205/2024-2025:Supply and installation of 304 Grade Stainless Steel Cable Tie of size 300mm x 4.6mm (12 Inch) used for Roof Top Solar and Industrial Purpose etc. The tie shall have the specifications of high strength, zip and self locking, shiny surface, smooth rounded edges to ensure safety, antioxidative, anti-caustic, high temperature resistant, cold resistant etc. complete as required

50

-

-

... More
OD197194/2024-2025:Supply and installation of Nylon 66 Cable Tie of size 300mm x 3.6mm (12 Inch) used for Roof Top Solar and Industrial Purpose etc. The tie shall have the specifications of UV resistance, high strength, zip and self locking, flammability UL 94 HB, operating temperature -40 Deg.C to +140 Deg.C, RoHS compliance etc. complete as required

99

-

-

... More
OD197199/2024-2025:Supply and installation of Nylon 66 Cable Tie of size 150mm x 2.5mm (6 Inch) used for Roof Top Solar and Industrial Purpose etc. The tie shall have the specifications of UV resistance, high strength, zip and self locking, flammability UL 94 HB, operating temperature -40 Deg.C to +140 Deg.C, RoHS compliance etc. complete as required

100

-

-

... More
OD197192/2024-2025:Supply and installation Wall Mounting 10KW ON GRID DC Distribution Board made of Thermoplastic Polycarbonate Glass Fibre Reinforced material for 1000V DC supply system having Design Standard according to IEC 60 364-7-712 and IEC 61439-1 and 2, Design Temperature of 50 Deg.C, IP 65 Degree of Protection (EN 60529), RAL 7035 (Self Finish Grey) Finish shade for enclosure with all components and connections including cable, lugs, sleeves, ferrules, screws and other necessary accessories etc. The main components shall be as follows. INTERNALS 6 Nos - 15A DC Fuse Link with Base 3 Nos - 25A 1000V DC Isolator with Direct Handle 3 Nos - Surge Arrester Type II 1000V DC TERMINAL BLOCKS 12 Nos - 6.0 Sq.mm Terminal Block for Outgoings 3 Nos - 10 Sq.mm Terminal Block for Earthing of SPD CABLE SIZE 6 Nos - 1C x 6.0 Sq.mm Cable for Incoming 6 Nos - 1C x 6.0 Sq.mm Cable for Outgoing 3 Nos - 1C x 10.0 Sq.mm Cable for Earthing of SPD CABLE GLAND 6 Nos - M20 Cable Gland for Incoming 6 Nos - M20 Cable Gland for Outgoings 3 Nos - M20 Cable Gland for Earthing of SPD 2 Nos - DEW Guard with Fixing Tape INTERNAL WIRING 6.0 Sq.mm Cable from Negative and Positive Fuses to Isolator, 6.0 Sq.mm Cable from Isolator to Outgoing Terminal Block Connector, 10.0 Sq.mm Cable from Outgoing Terminal Block Connector to SPD etc. complete as required

1

-

-

... More
OD197214/2024-2025:Supply and installation of Wall Mounting 5KW OFF GRID DC Distribution Board made of Thermoplastic Polycarbonate Glass Fibre Reinforced material for 1000V DC supply system having Design Standard according to IEC 60 364-7-712 and IEC 61439-1 and 2, Design Temperature of 50 Deg.C, IP 65 Degree of Protection (EN 60529), RAL 7035 (Self Finish Grey) Finish shade for enclosure with all components and connections including cable, lugs, sleeves, ferrules, screws and other necessary accessories etc. The main components shall be as follows. INTERNALS 2 Nos - 15A DC Fuse Link with Base 1 Nos - 25A 1000V DC Isolator with Direct Handle 1 Nos - Surge Arrester Type II 1000V DC TERMINAL BLOCKS 2 Nos - 6.0 Sq.mm Terminal Block for Incoming 2 Nos - 6.0 Sq.mm Terminal Block for Outgoing 1 Nos - 10 Sq.mm Terminal Block for Earthing of SPD CABLE SIZE 2 Nos - 1C x 6.0 Sq.mm Cable for Incoming 2 Nos - 1C x 6.0 Sq.mm Cable for Outgoing 1 Nos - 1C x 10.0 Sq.mm Cable for Earthing of SPD CABLE GLAND 2 Nos - M20 Cable Gland for Incoming 2 Nos - M25 Cable Gland for Outgoings 1 Nos - M20 Cable Gland for Earthing of SPD 2 Nos - DEW Guard with Fixing Tape INTERNAL WIRING 6.0 Sq.mm Cable from Negative and Positive Fuses to Isolator, 6.0 Sq.mm Cable from Isolator to Terminal Block Connector, 10.0 Sq.mm Cable from Terminal Block Connector to SPD etc. complete as required

2

-

-

... More
OD197187/2024-2025:Supplying and fixing of following sizes of PVC wall trunking / duct system with base perforation, cable retaining clip, 1 Nos of insertable partitions etc. complete along with all accessories in surface / recess including cutting the wall and making good the same in case of recessed installation as required Up to and including 60 X 50mm (Height X Width)

28

-

-

... More
OD197211/2024-2025:Supply, installation, testing and commissioning of ON GRID String Inverter at any combination of total output power of 10KW conforming to Central Electricity Authority, Electrical Inspectorate and KSEBL Standards with necessary Anti - Islanding property, IS / IEC Certifications etc. The Inverter shall have the following detailed specifications. INPUT DC Maximum DC Input Power 12KW, Maximum DC Input Voltage 1000V, Start-up Voltage 180V, MPPT Voltage Range 160V to 850V, Maximum Input Current 11A + 11A, Maximum Short Circuit Current for each MPPT 17.2A + 17.2A, Number of MPPT 2, Number of Strings per MPPT 1 OUTPUT AC Rated Output Power 10KW, Maximum Apparent Output Power 11kVA, Maximum Output Power 11KW, Rated Grid Voltage 400V, Grid Voltage Range 313V to 470 (Adjustable), Rated Grid Frequency 50/60Hz, Grid Frequency Range 47Hz to 52Hz or 57Hz to 62Hz, Operation Phase 3, Rated Grid Output Current 14.4A, Maximum Output Current 15.9A, THDi (at rated output power) less than 1.5%, DC Injection Current less than 0.5%ln EFFICIENCY Maximum Efficiency 98.7%, European Efficiency 98.1%, MPPT Efficiency greater than 99.5% PROTECTIONS Built-in Protections of DC Reverse Polarity, Short Circuit Protection, Output Over Current, Output Over Voltage, Insulation Resistance Monitoring, Residual Current Detection, MOVs for Surge Protection on DC and AC Sides, Grid Monitoring, Islanding Protection, Temperature Protection GENERAL DATA Topology Transformerless, Self Consumption less than 1W (Night), Operating Ambient Temperature Range – 25 Deg.C to 60 Deg,C, Relative Humidity 0 to 100%, Ingress Protection IP 65, Noise Emission (typical) less than 30 dBA , Cooling Concept Natural, Maximum Operating Altitude 4000m, Design Life greater than 20 Years FEATURES DC Connection MC4 Mateable, AC Connection IP 67 Rated Plug, Display LCD 2 x 20 Z, Communication Monitoring Interface RS 485, WiFi / GPRS / LAN IEC CERTIFICATIONS Grid Connection IEC 61727, Anti-Islanding Protection IEC 62116, Environmental Testing IEC 60068-2 (1-2-14-27-30-64), Safety IEC 62109-1, IEC 62109-2, EN 62109-1, EN 62109-2, EMC IEC 61000, EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, Efficiency Measurement IEC 61683, EN 50530 etc. complete as required

1

-

-

... More
OD197193/2024-2025:Supply, installation, testing and commissioning of OFF GRID Inverter at any combination of total output power of 5KW conforming to Central Electricity Authority, Electrical Inspectorate and KSEBL Standards with necessary properties, IS / IEC Certifications etc. The Inverter shall have the specifications of PV controller topology MPPT, Rated capacity 5.2KVA, Battery nominal voltage 48V to 96V, Maximum PV input voltage (Voc) 265V to 360V, MPPT operating voltage range (Vmp) 40V to 230V or 130V to 300V, Minimum PV voltage (Voc) 70V to 160V, Maximum PV input current 26A to 27A, Maximum battery charging current from PV 30A (Configurable 5A to 50A), No. of output phase 1, Inverter output voltage 230V + or - 1%, Output frequency 50Hz + or - 0.1Hz, Output power factor 0.8, Ingress protection IP 21, Battery under-voltage and over-voltage Protections, Overcharge Protection, Battery reverse polarity Protection, PV reverse polarity Protection, PV reverse current flow Protection, PV surge Protection, Grid input over-voltage Protection, Grid inputs under-voltage Protection, Grid frequency out of range Protection, Grid input surge voltage Protection, Overload Protection, Inverter over-temperature Protection, Battery short circuit Protection, Load short circuit Protection, Cooling type Air Cool, PV/Grid/Load input connector type Terminal Block etc. complete as required

2

-

-

... More
OD197202/2024-2025:Supply, laying, testing and commissioning of 1.1kV Grade Flame Retardant Low Smoke (FRLS) or Heat Resistant and Flame Retardant (HRFR) PVC insulated single core copper conductor cables of the following sizes conforming to IS 694 for all battery interconnections and battery to inverter connections etc. complete as required 1C X 35 Sq.mm

7

-

-

... More
OD197206/2024-2025:Supply and laying of 1.1kV Grade Flame Retardant Low Smoke (FRLS) or Heat Resistant Flame Retardant (HRFR) PVC insulated multi / single core copper conductor cables of the following sizes conforming to IS: 694 and laying through existing PVC wall trunking / ducts, cable trays using cable ties or clamps, clamping through walls using Aluminium Strip / spacer saddles etc. complete as required 1C X 25 Sq.mm

8

-

-

... More
OD197190/2024-2025:Supply and laying of 1.1kV Grade Flame Retardant Low Smoke (FRLS) or Heat Resistant Flame Retardant (HRFR) PVC insulated multi / single core copper conductor cables of the following sizes conforming to IS: 694 and laying through existing PVC wall trunking / ducts, cable trays using cable ties or clamps, clamping through walls using Aluminium Strip / spacer saddles etc. complete as required 1C X 16 Sq.mm

45

-

-

... More
OD197209/2024-2025:Supply and laying of 1.1kV Grade Flame Retardant Low Smoke (FRLS) or Heat Resistant Flame Retardant (HRFR) PVC insulated multi / single core copper conductor cables of the following sizes conforming to IS: 694 and laying through existing PVC wall trunking / ducts, cable trays using cable ties or clamps, clamping through walls using Aluminium Strip / spacer saddles etc. complete as required 4C X 10 Sq.mm

2

-

-

... More
OD197215/2024-2025:Supply and laying of 1.1kV Grade Flame Retardant Low Smoke (FRLS) or Heat Resistant Flame Retardant (HRFR) PVC insulated multi / single core copper conductor cables of the following sizes conforming to IS: 694 and laying through existing PVC wall trunking / ducts, cable trays using cable ties or clamps, clamping through walls using Aluminium Strip / spacer saddles etc. complete as required 1C X 10 Sq.mm

2

-

-

... More
OD197188/2024-2025:Supply of superior quality copper sockets (banana / palm / pin / ring) for each core of the following size of copper conductor cable including crimping and giving connections etc. complete as required 35mm / 25mm

24

-

-

... More
OD197204/2024-2025:Supply of superior quality copper sockets (banana / palm / pin / ring) for each core of the following size of copper conductor cable including crimping and giving connections etc. complete as required 16mm / 10mm

26

-

-

... More
OD197208/2024-2025:Supply of superior quality copper sockets (banana / palm / pin / ring) for each core of the following size of copper conductor cable including crimping and giving connections etc. complete as required 6mm / 4mm

4

-

-

... More
OD197189/2024-2025:Supply, installation, testing and commissioning of Wall Mounting 10KW ON GRID AC Distribution Board made of Thermoplastic Polycarbonate Glass Fibre Reinforced material for 415 V, Three Phase, 4 Wire, 50 Hz AC supply system having Design Standard according to IEC 60364-7-712 and IEC 61439-1 and 2, Design Temperature of 50 Deg.C, IP 65 Degree of Protection (EN 60529), RAL 7035 (Self Finish Grey) Finish shade for enclosure with all components and connections including cable, lugs, sleeves, ferrules, screws and other necessary accessories etc. The main components shall be as follows INTERNALS 1 Set - RYB Indication Lamps with Control MCBs 1 Nos - 25A/20A 10kA 4P C Curve MCB 1 Nos - Surge Arrester Type I + II 400V AC CABLE SIZE 1 Nos - Up to and including 4C x 10 Sq.mm Flame Retardant Low Smoke (FRLS) or Heat Resistant Flame Retardant (HRFR) Single Core Copper Conductor Cable for Incoming 1 Nos - Up to and including 4C x 16 Sq.mm A2XFY Cable for Outgoing 1 Nos - 1C x 16.0 Sq.mm Flame Retardant Low Smoke (FRLS) or Heat Resistant Flame Retardant (HRFR) Single Core Copper Conductor Cable for Earthing of SPD CABLE GLAND 1 Nos - Up to and including 4C x 10 Sq.mm Flame Retardant Low Smoke (FRLS) or Heat Resistant Flame Retardant (HRFR) Single Core Copper Conductor Cable for Incoming 1 Nos - Up to and including 4C x 16 Sq.mm A2XFY Cable for Outgoing 1 Nos - M25 Cable Gland for Earthing of SPD 2 Nos - M25 Cable Gland for Earthing INTERNAL WIRING 16.0 Sq.mm Flame Retardant Low Smoke (FRLS) or Heat Resistant Flame Retardant (HRFR) Single Core Copper Conductor Cable for Phase and Neutral Conductors from MCB to SPD etc. complete as required

1

-

-

... More
90.12.7.41:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp

15

-

-

... More
9.1.33:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)

4

-

-

... More
OD197191/2024-2025:Supply and providing gland earthing using Gland Earthing Clips / Clamps for following size of PVC insulated and PVC sheathed / XLPE Aluminium cable of 1.1 kV grade etc. complete as required 4 X 16 Sq.mm

4

-

-

... More
OD197198/2024-2025:Supply and installation of Wall Mounting 10KW ON GRID Three Phase Meter Board made of Thermoplastic Polycarbonate Glass Fibre Reinforced material having Environment friendly, recyclable, UV resistant, halogen and silicon free, anti-acid and anti-corrosive properties etc. complete as required. The main components shall be as follows. INTERNALS 1 Nos - Provision for fixing Energy Meter There shall be Separate Compartment for Energy Meter with KSEBL Sealing Provision 1 Set - RYB Indication Lamps with Control MCBs 1 Nos - 25A/20A 10kA 4P C Curve MCB CABLE SIZE 1 Nos - Up to and including 4 x 16 Sq.mm A2XFY Cable for Incoming 1 Nos - Up to and including 4C x 16 Sq.mm A2XFY Cable for Outgoing CABLE GLAND 1 Nos - Up to and including 4 x 16 Sq.mm A2XFY Cable for Incoming 1 Nos - Up to and including 4C x 16 Sq.mm A2XFY Cable for Outgoing 2 Nos - M25 Cable Gland for Earthing INTERNAL WIRING 2.5 / 1.5 Sq.mm Flame Retardant Low Smoke (FRLS) or Heat Resistant Flame Retardant (HRFR) Single Core Copper Conductor Cable for Control Wiring etc. complete as required

1

-

-

... More
OD197212/2024-2025:Supply and installation of the following Energy Meter after getting it duly tested from Electrical Inspectorate / TMR KSEBL. The scope also includes the supply and installation of mounting screws, 10.0 Sq.mm 1.1kV Grade Flame Retardant Low Smoke (FRLS) or Heat Resistant and Flame Retardant (HRFR) PVC insulated copper conductor single core cables for providing connections from Energy Meter to 4P MCB with copper sockets (banana / palm / pin / ring) for providing connections including crimping etc. complete as required. (*All Statutory fees shall be remitted by the client/consumer or it shall be reimbursed on the submission of supporting documents) Three Phase LT TOD Direct Operated Energy Meter (CL:1)

1

-

-

... More
OD197182/2024-2025:Supply and installation of ISI Marked Nickel Sealed Copper Bonded 16mm dia, 1m long Vertical Air Termination Rod with Tinned Spike and Nylon Insulated Base manufactured in accordance with latest International, Indian Standards and Regulations. The material shall have the specifications of Base Material Mild Steel, Coating Material 99.9% Pure Electrolytic Copper, Coating Thickness 100 microns, 1 Nos of Tinned Copper Bonded Spikes, Tin Coating on Spikes 10 microns, Insulated Base Material Nylon conforming to IS / IEC 62305-3:2010, IEC 62561-2:2018 etc. complete as required

3

-

-

... More
OD197183/2024-2025:Supply and laying of 50.0 Sq.mm single core flexible Aluminium conductor cable designed to withstand the demanding environmental conditions that arise in any fixed, mobile, roof or architecturally integrated Photovoltaic Lightning Protection System through the existing conduit etc. with all necessary accessories. The cable shall have the specifications of Base Material Aluminium in accordance with IS / IEC 62305-3:2010, Diameter of each strand 8mm, Insulation Material PVC Compound with UV Resistant, Nominal Insulation Thickness 2mm, DC Conductor Resistance at 20 Deg.C 0.641 Ohms/Km, Insulation Resistance Constant at 20 Deg.C (Min) 36.70 M.Ohm/Km, HV Test Core to Water 10kV for 5 minutes etc. complete as required

75

-

-

... More
OD197200/2024-2025:Supply of superior quality Aluminium palm socket for 50.0 Sq.mm single core flexible Aluminium conductor cable including crimping, giving connections to the required conductor or surface using Stainless Steel bolts, nuts, round and spring washer etc. complete as required

12

-

-

... More
OD197197/2024-2025:Earthing with ISI Marked Nickel Sealed Copper Bonded 20mm dia, 3.0m long Rod having 250 microns coating thickness with T clamp including Stainless Steel bolts, nuts, round and spring washers etc. and providing masonry enclosure with cover plate having locking arrangement with sufficient earthing compound etc. complete as required

6

-

-

... More
OD197207/2024-2025:Excavation of all types of soils for the laying of PVC insulated and PVC sheathed / XLPE Aluminium or Copper conductor cable, GI / DWC HDPE / RCC / PVC / Conduit Pipes, Earthing conductors to the required width and depth up to and including 0.75m and back filling etc. complete as required. (The trench dimensions and specifications shall conform to CPWD / PWD, Electrical Inspectorate and KSEBL Standards)

35

-

-

... More
OD197196/2024-2025:Supply and installation of 10 kg/cm2 PVC Pipes of the following sizes with all necessary accessories and laying in existing excavated trenches, built up trenches, clamping in built up trenches / walls using Stainless Steel saddles and screws of which spacing between 30cm to 60cm including all minor civil works etc. complete as required Up to and including 32mm

35

-

-

... More
90.16.1.5:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.75 mm copper conductor (6 SWG)

32

-

-

... More
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)

106

-

-

... More
OD197186/2024-2025:Supply, installation, testing and commissioning of Tinned Stainless Steel Earth Bench/Terminal Strip of 8 Poles manufactured in accordance with IS/IEC 62305-3:2010 and IEC 62561-2:2012 with screws, nuts, bolts, round and spring washers etc. The Terminal Strip shall have the specifications of minimum Width 25mm, Thickness 4mm, insulations provided at mounting ends etc. complete as required

9

-

-

... More
90.16.5.5:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.75 mm (6 SWG)

12

-

-

... More
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)

45

-

-

... More
OD197210/2024-2025:Supply, installation, testing and commissioning of Ultra Low Maintenance Solar Tubular battery conforming to IS 13369 with latest amendments. The battery shall have the specifications of Nominal Voltage 12V, Capacity @C10 up to 1.80 v.p.c (Volts per cell) at 27 Deg.C 200Ah, Battery weight with acid 75Kg + or - 5%, Dimensions 500 x 187 x 421mm (LXWXH) having + or -5mm tolerance, Suitable for frequent cyclic duty, Superior cycle life, supplied in factory charged condition that ensures optimal quality and ready to use etc. complete as required

8

-

-

... More
OD197184/2024-2025:Supply and installation of Three Phase 4 Wire LT CT Operated Bidirectional Net Meter strictly conforming to the relevant KSERC, KSEBL and Electrical Inspectorate standards. The Energy Meter shall have the specifications of Accuracy Class of 0.5S as per relevant IS and IEC Standards, Rated Voltage 3 x 240V (P-N), Voltage Variation -40% to +20%, Current Rating -/5A, Starting Current 0.1% of basic current, Accuracy up to 200% of basic current, Frequency 50Hz, Frequency Variation -5% to +5%, Power Consumption As per IS 14697, Operating Temperature -10 Deg.C to +55 Deg.C, Ingress Protection IP 51, LCD 8 digit backlit display, LED Pulse LEDs for kWh and kVArh, 4 quadrant measurement of kWh, kVArh and kVAh, Maximum Demand kW and kVA along with date and time, Anti-tamper features, Self-diagnostic capability, Multiple tariff / Time of day feature, Bidirectional Energy recording, , Load Survey (Interval Data) features, Up to 12 reset backups, Optical port /RS 232 / RS 485 / IR / IrDA / RF (2.4 GHz/865-867 MHz) etc. complete as required. The scope also includes the testing of Energy Meter from Electrical Inspectorate / TMR KSEBL. (*All statutory fees shall be remitted by the client/consumer or it shall be reimbursed on the submission of supporting documents)

1

-

-

... More
OD197203/2024-2025:Supply, installation, testing and commissioning of 200 Litre capacity Solar Water Heater having the specifications of Diameter of Outer tank 480mm, Thickness of Insulation layer 50mm, Density of PUF Insulation 35 to 40kg/m3, Material of Outer Cylinder Zinc-Alum Sheet, Material of Inner Tank SS 304 L, Quantity of Vacuum Tube 20 Nos, Vacuum Tube Diameter 58mm, Vacuum Tube Length 1800mm, Material of Stand GI Plus Powder Coating, Absorbing Area 3.3m2, Angle of Stand 25 Degree, Corrosion Protection Mg Anode, Inlet Pipe (Left Bottom) 3/4 Inch BSP Nos, Outlet (Right Top) 3/4 Inch BSP Nos etc. The scope also includes providing M.20 Grade (1:1.5:3) PCC concreating works of base of structures etc. and also the supply and installation of Water Heater pipe line systems using up to and including 25mm size of CPVC SDR 11 Pipe with all necessary accessories like couplings, elbows, tees, valves, solvents, Stainless Steel clamps, screws and taps etc. complete as required as per the local site conditions

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.