Kerala State Construction Corporation Limited Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kerala State Construction Corporation Limited - KSCC Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date19 Nov 2022
Closing Date26 Nov 2022
Tender Amount₹ 1,99,02,994 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
OD143295/2021-2022:Supply and wiring points according to IS 732-1989 using rigid PVC medium conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, cutting the walls, fixing the conduit concealed suitably and with 1.50 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with 1.50 sq mm green coloured FRLS PVC insulated stranded single core copper conductor cable 650V grade, required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories). Single control light point without ceiling rose - Short point

258

-

-

... More
OD143296/2021-2022:Supply and wiring points according to IS 732-1989 using rigid PVC medium conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, cutting the walls, fixing the conduit concealed suitably and with 1.50 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with 1.50 sq mm green coloured FRLS PVC insulated stranded single core copper conductor cable 650V grade,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control ceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator. - Short point

224

-

-

... More
OD143297/2021-2022:Supply and wiring points according to IS 732-1989 using rigid medium gauge PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, cutting the walls, fixing the conduit concealed suitably and with 1.50 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with 1.50 sq mm green coloured FRLS PVC insulated stranded single core copper conductor cable 650V grade, required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories). Call bell point with 6 A bell push at one end and 6 A, 3 plate ceiling rose at other end - Short point

22

-

-

... More
OD143298/2021-2022:Supply and wiring points according to IS 732-1989 using rigid PVC medium conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, cutting the walls, fixing the conduit concealed suitably and with 1.50 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with 1.50 sq mm green coloured FRLS PVC insulated stranded single core copper conductor cable 650V grade, required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories). Combined plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of light points

80

-

-

... More
OD143299/2021-2022:Supply and wiring points according to IS 732-1989 using rigid PVC medium gauge conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988,cutting the walls, fixing the conduit concealed suitably and with 1.50 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with 1.5 sqmm green coloured FRLS PVC insulated stranded single core copper conductor ,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories). Independent plug - Short point

30

-

-

... More
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

3000

-

-

... More
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

800

-

-

... More
1.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm

200

-

-

... More
1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)

20

-

-

... More
1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)

50

-

-

... More
1.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)

20

-

-

... More
1.27.5:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)

15

-

-

... More
90.10.1.1:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )1 module moulded plastic box on surface

50

-

-

... More
90.10.1.3:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )3 module moulded plastic box on surface

50

-

-

... More
90.10.1.5:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )6 module moulded plastic box on surface

50

-

-

... More
1.28.1:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module

50

-

-

... More
1.28.2:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module

50

-

-

... More
1.28.4:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module

50

-

-

... More
1.17.1:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.1 x 1.5 sq. mm

300

-

-

... More
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm

4500

-

-

... More
1.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm

500

-

-

... More
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm

1250

-

-

... More
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm

1000

-

-

... More
1.17.22:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 4 sq. mm

100

-

-

... More
1.17.31:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 6 sq. mm

600

-

-

... More
1.18.2:Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair

400

-

-

... More
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch

180

-

-

... More
1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch

30

-

-

... More
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet

360

-

-

... More
1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet

40

-

-

... More
1.24.6:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet

50

-

-

... More
1.24.7:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet

4

-

-

... More
OD143300/2021-2022:Supply and Fixing 20A DP Switch modular switches & accessories in the existing front plates and giving necessary connections as required

10

-

-

... More
1.26:Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

50

-

-

... More
1.22.1:Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.75 mm X 75 mm X 60 mm deep

22

-

-

... More
90.5.1.3:Supply and fixing the following types of superior quality 250V A.C call bell on existing M.S. box and giving connections with required length of 3 core, 16 / 0.20mm 650/1100V grade PVC insulated and PVC sheathed round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, earthing the MS box and making good the surface as required.Ding dong bell

11

-

-

... More
90.5.1.4:Supply and fixing the following types of superior quality 250V A.C call bell on existing M.S. box and giving connections with required length of 3 core, 16 / 0.20mm 650/1100V grade PVC insulated and PVC sheathed round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, earthing the MS box and making good the surface as required.Musical bell with bird sound

11

-

-

... More
90.3.20.3:Supply & installation of light fittings on TW round block <br> Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture

52

-

-

... More
90.3.21.3:Supply & installation of light fittings on 'C/U' shaped flat iron bracket <br> Supply, conveyance, installation, testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet complete with all accessories and lamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200 mm 1X20W LED Lamp with box type fixture

249

-

-

... More
90.3.24.3:Supply & installation of light fittings suspended on ball & socket arrangement with 19 mm down rod <br> Supply, conveyance, installation, testing and commissioning the light fittings of following types made of .5mm thick CRCA sheet accessories and lamps etc. including supplying and fixing ball and socket arrangements on PVC round block, suspension down rod of 19mm dia MS conduit up to 2x30cm length including painting and wiring the down rod with 16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connections etc. a required.1200 mm 1X20W LED Lamp with box type fixture

50

-

-

... More
90.3.24.4:Supply & installation of light fittings suspended on ball & socket arrangement with 19 mm down rod <br> Supply, conveyance, installation, testing and commissioning the light fittings of following types made of .5mm thick CRCA sheet accessories and lamps etc. including supplying and fixing ball and socket arrangements on PVC round block, suspension down rod of 19mm dia MS conduit up to 2x30cm length including painting and wiring the down rod with 16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connections etc. a required.1200 mm 2X20W LED Lamp with box type fixture

100

-

-

... More
OD143302/2021-2022:Supply and fixing low glare high efficiency square surface mounted LED flat panel 230V 50Hz 36 w light fitting complete with all required accessories etc. as required

80

-

-

... More
OD143303/2021-2022:Supply and fixing low glare high efficiency square surface mounted LED flat panel 230V 50Hz Compton make LCDSPLN-S-18-CDL 18 w light fitting complete with all required accessories etc. as required

40

-

-

... More
OD93755/2022-2023:Supply and fixing LED recessed round recesses mounted LED edge-lit slim downlight with die-cast aluminum housing finished in premium white powder coating Efficacy 100lm/w 15W 230V 50Hz Compton make LSCRM-15W-CDL light fitting complete with all required accessories etc. as required

30

-

-

... More
90.3.17.1:Supply, conveyance and erection of the following sizes of 'B' class GI pipe in single section for post top lantern of all types on concrete base (excluding charges for concrete base and excavation) and painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer etc. as required.32 mm dia GI pipe

8

-

-

... More
90.3.18.1:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.25 mm dia with HG company fabricated clamps

36

-

-

... More
90.15.4.1:Supply Conveyance, installation, testing and commissioning of 20W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)

18

-

-

... More
90.15.4.2:Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)

4

-

-

... More
OD143304/2021-2022:Supply , installation, testing and commissioning of 40 w LED Post top lantern with IP 65 protection make Compton LPTO-40-CDL on existing GI post.(gate light)

8

-

-

... More
OD143305/2021-2022: Supply and providing Thermoplastic distribution board on pillar in concealed position including providing SP MCB of required size and giving connection as required

12

-

-

... More
OD143306/2021-2022:Supply and erecting 5m high FRP pole on existing foundation in correct vertical alignment using 4 nos foundation bolt of size 16 mm x450 mm and with single arm bracket 1 M long

4

-

-

... More
14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.

4

-

-

... More
14.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.

4

-

-

... More
14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels

4

-

-

... More
OD143301/2021-2022:Supplying and fixing PVC batten/ angle holder with PVC shade, 9W LED bulb and giving connection etc. as required.

108

-

-

... More
90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.

195

-

-

... More
90.4.2:Supply and installation of suitable size MS belt type fan clamp fabricated from flat iron 40 x 6 mm, 150mm long x 2 Nos with M.S. rod bent to shape, neatly painted with 2 coats of enamel paint over a coat of red oxide primer as per IS 732 as required.

29

-

-

... More
OD93752/2022-2023:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 1200mm sweep - ceiling fan 3 star rated, complete with service value minimum 5.0(cub meter/minute/Watt), Air delivery minimum 215(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply

224

-

-

... More
OD94651/2022-2023:Supply, Installation, testing and commissioning of Wall fan of following sizes as required. 400mm sweep - Wall fan complete with Air delivery minimum 67(cubic meter/minute) ,1200 rpm, suitable for 230V/240V single phase AC supply

30

-

-

... More
90.4.8:Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.

45

-

-

... More
90.4.9:Charges for cutting holes suitable for accommodating exhaust fans above 305mm sweep and up to 450mm sweep including plastering colour washing etc. as required.

14

-

-

... More
OD143309/2021-2022:Supply, conveyance, installation, testing and commissioning of 380 mm, single phase, heavy duty, 1400 rpm exhaust fan in metal frame in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of 24/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS.

14

-

-

... More
OD143310/2021-2022:Supply, conveyance, installation, testing and commissioning of 225mm light duty exhaust fan in metal frame in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of 24/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS.

45

-

-

... More
90.9.1.1:Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.50x50mm Cable Management System with base and lid

300

-

-

... More
90.9.1.2:Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.External angle 90 degree

20

-

-

... More
90.9.1.4:Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Internal angle 90 degree

20

-

-

... More
90.9.1.7:Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.End cap

20

-

-

... More
90.9.1.9:Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Joint cover

15

-

-

... More
90.9.1.10:Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Cable retainer

200

-

-

... More
90.9.1.16:Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Flat tee

5

-

-

... More
90.9.2.1:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.100 x 50 mm CMS with base and lid

100

-

-

... More
90.9.2.2:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Cable devider

100

-

-

... More
90.9.2.3:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.External angle 90 degree

10

-

-

... More
90.9.2.4:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Flat angle 90 degree

10

-

-

... More
90.9.2.5:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Internal angle 90 degree

10

-

-

... More
90.9.2.7:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Flat cross

10

-

-

... More
90.9.2.8:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.End cap

10

-

-

... More
90.9.2.10:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Joint cover

10

-

-

... More
90.9.2.11:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Cable retainer

50

-

-

... More
90.9.2.12:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.1 to 3 module mounting box

10

-

-

... More
90.9.2.13:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.4 to 5 module mounting box

10

-

-

... More
OD94655/2022-2023:Supply, testing and installation of 24-Ports 10/100/1000 Base-T ports + 4 SFP ports Metro Switch or equalent

4

-

-

... More
OD94656/2022-2023:Supply, testing and installation of Patch panel Cat6 UTP Keystone Type-24port-fully Loaded Make - D Link NPP-C61BLK241 or equivalent

4

-

-

... More
OD94657/2022-2023:Supply and installation of Wall Mount 9U x 550 W x 500 D ,Front Glass Door (tinted,Toughened) with Lock & Key,2 pairs of 19 Mounting Rails with U-Marking Welded Side Walls With Metal Engraved D-Link Logo Standard Accessories :1U Cable Manager 1,Hardware Packet 1 Pkt 6 Socket 5 Amp.Power Distribution Unit 1 No Roof Mounted Fan Unit 90CFM 230V AC 1 No

4

-

-

... More
OD94658/2022-2023:Supply and installation of Wall Mount 12U x 550 W x 500 D ,Front Glass Door (tinted,Toughened) with Lock & Key,2 pairs of 19 Mounting Rails with U-Marking Welded Side Walls With Metal Engraved D-Link LogoStandard Accessories :1U Cable Manager 1, Hardware Packet 1 Pkt 6 Socket 5 Amp.Power Distribution Unit (1 No) Roof Mounted Fan Unit 90CFM 230V AC 1 No

4

-

-

... More
OD94659/2022-2023:Supply, testing and installation of Cat6 UTP 24AWG PATCH CHORD:2M,Plug 30U' Make - D Link NCB-C6UGRYR1-2 or equivalent

96

-

-

... More
OD94660/2022-2023:Supply, testing and installation of Cat6 UTP 24AWG PATCH CHORD:1M,Plug 30U'Make - D Link NCB-C6UGRYR1-1 or equivalent

96

-

-

... More
OD94661/2022-2023:Supply, testing and installation of Back Box Make - D Link NBB-011 or equivalent or equivalent

96

-

-

... More
OD94662/2022-2023:Supply, testing and installation of Face Plate-Single(Keystone jack, square) Make - D Link NFP-OWHI11 or equivalent

96

-

-

... More
OD94663/2022-2023:Supply, testing and installation of Jack Cat6 Keystone UTP with Collapsible Shutter-White Make - D Link NKJ-C6WHI1B21 or equivalent

96

-

-

... More
1.53.1:Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable

1500

-

-

... More
90.11.1.10:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)

8

-

-

... More
90.11.1.11:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43)

8

-

-

... More
90.11.1.12:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - three phase double cover (IP 42/43)

5

-

-

... More
90.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)

12

-

-

... More
90.11.1.15:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)

2

-

-

... More
2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door

4

-

-

... More
2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door

7

-

-

... More
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

352

-

-

... More
2.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole

23

-

-

... More
OD92890/2022-2023:Supplying and fixing 40 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole

16

-

-

... More
2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

30

-

-

... More
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

13

-

-

... More
2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

26

-

-

... More
2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps

3

-

-

... More
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps

10

-

-

... More
2.15.1:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps

12

-

-

... More
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

11

-

-

... More
2.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps

3

-

-

... More
2.16:Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.

8

-

-

... More
2.17:Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32amps 415 volts "C" curve TP MCB complete with connections, testing and commissioning etc. as required.

4

-

-

... More
OD92885/2022-2023:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof FP enclosure for independent mounting of MCB/ RCCB/ RCBO including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required

2

-

-

... More
90.14.1.1:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.<br> Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 2.00mm CRCA sheet, powder coated (excluding base frame)

25

-

-

... More
90.14.2.2:Supply and providing 3mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.

2.5

-

-

... More
90.14.3.1:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardA' section neoprene beeding suitable for 1.60/ 2.00 mm sheet

40

-

-

... More
90.14.4:Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC)

20

-

-

... More
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board

40

-

-

... More
90.14.6:Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.

4000

-

-

... More
90.14.7:Supply and providing copper earth bus in the panel board

1800

-

-

... More
OD92891/2022-2023:Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables 1.50 sq mm single run with required sockets.conforming to IS 694 part I 1990 for interconnecting the control devices/ equipments including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required.

50

-

-

... More
OD92892/2022-2023:Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables 2.50 sq mm single run with required sockets.conforming to IS 694 part I 1990 for interconnecting the control devices/ equipments including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required.

50

-

-

... More
OD92895/2022-2023:Providing and fixing following capacity TP&N disconnector(ISOLATOR) switch complete with handle assembly in the existing panel : 125 Amp TP & N

1

-

-

... More
OD92896/2022-2023:Suppy and installation of 300/5, 15VA,accuracy class 1,Resin cast metering CT

6

-

-

... More
OD92897/2022-2023:Supply and fixing - Blue Colour LED indicator AC/DC 22.5 mm cut out dia

6

-

-

... More
OD92898/2022-2023:Supply and fixing LED indicators - Red, Green, Yellow or Orange Colour ,AC/DC, 22.5mm cut out dia

18

-

-

... More
OD92899/2022-2023:Three phase multifunction meters to read V, A and F, accuracy class 1(Digital type)

2

-

-

... More
90.14.10.5:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16A -100A, 35/36 kA (Ics=100%Icu), 3 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC

3

-

-

... More
90.14.10.7:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.160A, 35/36 kA (Ics=100%Icu), 3 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC

2

-

-

... More
90.14.10.8:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.200A, 35/36 kA (Ics=100%Icu), 3 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC

1

-

-

... More
90.14.10.9:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.250A, 35/36 kA (Ics=100%Icu), 3 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC

1

-

-

... More
90.14.24.31:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.5 KVAr, 3 phase, 440 V, Metalised Poly Propylene Heavy duty Cylindrical Gas filled Capacitor suitable for APFC panel without block reactor.

3

-

-

... More
90.14.24.34:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.10 KVAr, 3 phase, 440 V, Metalised Poly Propylene Heavy duty Cylindrical Gas filled Capacitor suitable for APFC panel without block reactor.

2

-

-

... More
OD92901/2022-2023:160A, 25/35 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL

1

-

-

... More
OD92902/2022-2023:16 A-100A, 25/35 kA (Ics=100%Icu), 3 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL

14

-

-

... More
90.14.11.3:MCCB AccessoriesSupply and fixing one number earth fault Relay up to 250A to 400A with CBCT.

1

-

-

... More
90.14.11.13:MCCB AccessoriesSupply and fixing rotary handle, External type (including BUC handle with door interlock ) in the existing MCCB of rating up to 250 A

1

-

-

... More
OD92903/2022-2023:Supply and providing 2mm thick Elastomeric fire retardant insulating mat as per IS 15652/2006 to withstand 3.3 KV dielectric strength including painting in ground with suitable synthetic adhesive

10

-

-

... More
OD92904/2022-2023:Supply of Electrical safety hand Glows 2.9mm minimum thickness,withstanding 26 KV protection made by Natural Latex, off white colour ( Certification shall be attached)

1

-

-

... More
OD92905/2022-2023:Supply and providing Plug in Relay , 10Amps, 2Pole, 240V AC, suitable for AMF operation with base plate for proper mounting and giving connections etc: as required. (Salzer Make)

1

-

-

... More
OD92906/2022-2023:Supply and providing Auxilary contactor for Control Relay , Type MXO 22E, 2 No: + 2NC:, 415V, L&T make for AMF Operation,

2

-

-

... More
OD92907/2022-2023:Supply and providing Rotary Selector switch, 415V, 4pole,2way for Remote/ auto manual operation . (Salzer Make)

1

-

-

... More
OD92908/2022-2023:Supply and providing Rotary Selector switch, 240V, 2pole,2way for Remote/ auto manual operation . (Salzer Make)

1

-

-

... More
OD92909/2022-2023:Supply and providing electronic delay timer for AMF operation. (Salzer Make)

1

-

-

... More
OD92910/2022-2023:Supply and Installation of AMF Logic Relay, EC2 Relay in the existing panel board and to made all control wiring with all accessories and make it proper working condition of automatic operation of DG and EB supply. (C&S Make)

1

-

-

... More
OD92911/2022-2023:Supply and fixing Flush head Push Button with 1 NC Block

5

-

-

... More
OD92912/2022-2023:Supply and fixing Flush head Push Button with 1 NO Block

5

-

-

... More
OD92913/2022-2023:Supply and fixing 3 pole, capacitor duty contactor with AC coil for switching capacitor banks of rating 7.5 - 10 KVAR & with 1 NO auxiliary contact in the existing panel assembly as required.

2

-

-

... More
OD92914/2022-2023:Supply and fixing 3 pole, capacitor duty contactor with AC coil for switching capacitor banks of rating 4 - 7 KVAR & with 1 NO auxiliary contact in the existing panel assembly as required.

3

-

-

... More
OD92915/2022-2023:Supply & fixing the Copper wound block reactor transformer, 400 V, 10 KVAr suitable for filtering harmonics up to 7% THD .

2

-

-

... More
OD92916/2022-2023:Supply & fixing the Copper wound block reactor transformer, 400 V, 5 KVAr suitable for filtering harmonics up to 7% THD .

3

-

-

... More
90.12.5.29:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 50 sq mm

50

-

-

... More
90.12.5.31:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 95 sq mm

50

-

-

... More
90.12.5.33:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 150 sq mm

40

-

-

... More
90.12.7.2:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp

300

-

-

... More
90.12.7.3:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 10 sq mm with factory made clamp

100

-

-

... More
90.12.7.30:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 70 sq mm

50

-

-

... More
90.12.7.38:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 4 sq mm with factory made clamp

70

-

-

... More
90.12.7.39:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 6 sq mm with factory made clamp

150

-

-

... More
90.12.7.40:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp

200

-

-

... More
90.12.7.41:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp

350

-

-

... More
90.12.7.42:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp

50

-

-

... More
90.12.10.4:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation77/63 mm or nearest size

190

-

-

... More
90.12.10.7:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation120/102.5 mm or nearest size

30

-

-

... More
90.12.10.13:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation200/174 mm or nearest size

30

-

-

... More
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)

740

-

-

... More
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)

1200

-

-

... More
90.16.1.4:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG)

280

-

-

... More
9.1.1:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm)

22

-

-

... More
9.1.2:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm)

4

-

-

... More
9.1.22:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)

4

-

-

... More
9.1.24:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 95 sq. mm (45mm)

2

-

-

... More
9.1.26:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 150 sq. mm (50mm)

2

-

-

... More
9.1.23:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)

4

-

-

... More
9.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)

10

-

-

... More
9.1.33:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)

12

-

-

... More
9.1.34:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)

2

-

-

... More
9.1.35:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 35 sq. mm (32mm)

2

-

-

... More
OD92920/2022-2023:Supplying and providing earth clamps made out of copper strips of 20 x 3 mm for earthing glands of size 120 sq mm to 185 sq mm including cutting and bending the flat exactly to the shape of the gland, drilling necessary holes for nut & bolt, tinning the points of contacts and giving connections to the main earthing system as required.

30

-

-

... More
OD92921/2022-2023:Supplying and providing earth clamps for siemens/ tripodular type cable glands of suitable length and other dimensions noted along with each size of glands for 25 sq - 95sq mm sizes of cables with 20 mm wide x 1.20 mm thick clip as required.

24

-

-

... More
OD92922/2022-2023:Supplying and providing earth clamps for siemens/ tripodular type cable glands of suitable length and other dimensions noted along with each size of glands for 4sqmm-16 sq mm sizes of cables with 12 mm wide x 1 mm thick clip as required.

80

-

-

... More
4.1.1:Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6 mm thickness

200

-

-

... More
4.1.2:Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness

200

-

-

... More
4.1.4:Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness

100

-

-

... More
OD92923/2022-2023:Supply and providing cable trays of all sizes with angle iron/flat iron suitable size painted with 2 coats of synthetic enamel paint over a coat of red oxide primer & with drilled holes to mount the switch gears/Cabel/machines for support , fixed to wall/floor using suitable size anchor bolts etc grouted to wall, making good the damages, colour washing etc as required.

200

-

-

... More
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

8

-

-

... More
5.8:Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)

100

-

-

... More
OD93727/2022-2023:Supply and providing test joint for the earthing system using 1 Nos of 2x25x3mm of Cu strip including cutting and bending to shape, drilling necessary holes and fixed to the watering pipe etc as required.

1.2

-

-

... More
OD93728/2022-2023:Supply and providing plate earthing as per IS 3043 with 1200x1200x12 mm GI/CI earth plate, 50 mm GI watering pipe fixed to the earth plate with 25 x 3mm GI clamps, GI funnel with weld mesh, filling required quantity of charcoal including construction of inspection chamber with a bed concrete of 1:4:8 PCC using 40 mm broken stone (10 cm thick), brick work in cement mortar 1:6, plastering the surface of brick masonry and the exposed surface of PCC bed with cement mortar 1:4, 12 mm thick, (the finished inside dimension shall be 450 x 450 x 450 mm) but excluding test joint, earth continuity conductor to the plate, and covering at the top. (in ordinary rocky - soft laterite soil)

2

-

-

... More
OD94638/2022-2023:Supply and providing cast iron gully trap of size 450 x 450 x 10 mm with covering at the top of the inspection chamber of earth pit as required

2

-

-

... More
OD93729/2022-2023:Supply and laying bare earthing conductors of size3.15 mm copper conductor (10 SWG) laid 0.6 m below ground level including excavating trench of suitable size and refilling etc. as required (in ordinary soil).

80

-

-

... More
OD93730/2022-2023:Supply and providing 25 x 3 mm GI strip earth lead from the test joint to the earth electrode using the following sizes of conductors/ strips including cutting, drilling necessary holes (in case of strip) and fixing firmly with plate test joint etc as required.

80

-

-

... More
OD93731/2022-2023:Supply and providing 25 x 6 mm brass bolt & nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required

50

-

-

... More
OD93732/2022-2023:Supply and providing 25 x 3 mm brass bolt & nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required

50

-

-

... More
OD93733/2022-2023:Supply and providing 12 x 3 mm brass bolt & nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required

50

-

-

... More
5.10:Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.

20

-

-

... More
5.14:Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.

40

-

-

... More
90.16.2.2:Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.20 mm dia. G.I pipe ( medium class)

30

-

-

... More
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)

40

-

-

... More
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)

40

-

-

... More
90.16.5.4:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG)

40

-

-

... More
90.16.3.9:Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 3 mm copper strip

200

-

-

... More
6.2:Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube,having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.

2

-

-

... More
6.3:Fixing of lightning conductor finial (single prong) with base plate including holes etc. complete as required.

2

-

-

... More
6.7:Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)

200

-

-

... More
6.8:Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)

180

-

-

... More
6.12:Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.

20

-

-

... More
6.14:Providing and laying G.l. tape 32 mm X 6 mm from earth. electrode directly in ground as required.

50

-

-

... More
OD93734/2022-2023:Supply and providing 3 Phase 3 HP borewell pump set (Texmo/CRI)

2

-

-

... More
OD93735/2022-2023: Supply and installation of 40 mm CPVC pipe on the delivery side of pump including giving connection to the existing pipe line.

100

-

-

... More
90.6.6.3:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm

150

-

-

... More
OD93736/2022-2023:Supply, installation, testing and commissioning of 1 No 13 TR( DSAI-1622R3, 2 No 8.0 TR( DSAI961R3) and 2 No 5.0 TR(DSAI-961R3) INVERTER Ducted split air conditioners with other ancillary works

1

-

-

... More
OD93737/2022-2023:Supply and installation one 13 passenger Lift (Gear less and with machine room), Rated speed .1 M / Sec., Travel 25.0 metre (approximately), No. of floor and entrance served 7 Floors , 7 Landings (7 Doors), with / with out attendant with Micro Processor controller, Stainless Steel 304 hairline cabin with rear side one panel mirror finish and mirror finish false ceiling, led lighting, strong air axial flow fan with diffuser and flooring with 20 mm thick granite slab. Available well size - 2500mm W x 2100mm D, Car size - 2000 mm Wide x 1300 mm Deep, Call indicator and position - UP/DN direction indication shall be provided at all landings-LCD indication, Electric supply - Suitable for operating in 415 V 50 Hz AC supply, Indications, digital push buttons and other requirements - Car position ( Inside the car and at all landings-LCD indication), Call indicator ( Inside the car LCD indication), button for Door close, Door open ( Inside the car ), Emergency stop button( Inside the car ), Flush mounted switch for fan and light. ( Inside the car ), Non stop button (Inside the car ), Battery operated emergency LED lamp with rechargeable batteries, Battery operated alarm bell, Intercom wiring with one master unit with two slaves, Fireman's switch at main lobby, Auto /Attendant control ( Inside the car ). Infra red door opening system shall be provided for the entire length. Automatic rescue device with an electronic controller and with suitable maintenance free batteries. The rescue operation shall act within 10 seconds of power failure. Manual winding wheel for car in case of an emergency, Automatic leveling at all landings, Safeties: Over speed governor, Buffers, Motor over speed protection, Phase reversal protection, Single Phase preventer, Final limit switch, Other safeties as per ISS. Control panel shall be accommodated on dust and vermin proof of sheet metal enclosure. Test at site as per IS to be carried out before Handing over. Scope of work - Supply of lift materials, Minor civil works such as construction of buffer block in the pit machine room, foundation necessary for mounting the control panel, cutting pockets and grouting brackets for guide rails, grouting boxes for control units in the front side. This does not include correction of wall opening on the front side of the wall, Scaffolding, Door frame, Supporting steel, Free servicing for 12 months after handing over, Electrical Inspectorate approval for lift installation, preparation of scheme and remittance of all fees and obtaining energization sanction from electrical inspectorate. Guarantee - Company shall carry out free maintenance during warranty period & includes Cleaning lift equipment, Lubrication of all parts, Replacing of lubricating oil when required, Checking and adjusting contacts, Replacing fusible items, alarm etc., Re charging batteries in case of drain / and or renewing of batteries if required and Replacing/ rewinding motors if required.

1

-

-

... More
OD93738/2022-2023:Supply and installation one 16 passenger Lift (Gear less and with machine room), Rated speed .1 M / Sec., Travel 25.0 metre (approximately), No. of floor and entrance served 7 Floors , 7 Landings (7 Doors), with / with out attendant with Micro Processor controller, Stainless Steel 304 hairline cabin with rear side one panel mirror finish and mirror finish false ceiling, led lighting, strong air axial flow fan with diffuser and flooring with 20 mm thick granite slab. Available well size - 2500mm W x 2100mm D, Car size - 2000 mm Wide x 1300 mm Deep, Call indicator and position - UP/DN direction indication shall be provided at all landings-LCD indication, Electric supply - Suitable for operating in 415 V 50 Hz AC supply, Indications, digital push buttons and other requirements - Car position ( Inside the car and at all landings-LCD indication), Call indicator ( Inside the car LCD indication), button for Door close, Door open ( Inside the car ), Emergency stop button( Inside the car ), Flush mounted switch for fan and light. ( Inside the car ), Non stop button (Inside the car ), Battery operated emergency LED lamp with rechargeable batteries, Battery operated alarm bell, Intercom wiring with one master unit with two slaves, Fireman's switch at main lobby, Auto /Attendant control ( Inside the car ). Infra red door opening system shall be provided for the entire length. Automatic rescue device with an electronic controller and with suitable maintenance free batteries. The rescue operation shall act within 10 seconds of power failure. Manual winding wheel for car in case of an emergency, Automatic leveling at all landings, Safeties: Over speed governor, Buffers, Motor over speed protection, Phase reversal protection, Single Phase preventer, Final limit switch, Other safeties as per ISS. Control panel shall be accommodated on dust and vermin proof of sheet metal enclosure. Test at site as per IS to be carried out before Handing over. Scope of work - Supply of lift materials, Minor civil works such as construction of buffer block in the pit machine room, foundation necessary for mounting the control panel, cutting pockets and grouting brackets for guide rails, grouting boxes for control units in the front side. This does not include correction of wall opening on the front side of the wall, Scaffolding, Door frame, Supporting steel, Free servicing for 12 months after handing over, Electrical Inspectorate approval for lift installation, preparation of scheme and remittance of all fees and obtaining energization sanction from electrical inspectorate. Guarantee - Company shall carry out free maintenance during warranty period & includes Cleaning lift equipment, Lubrication of all parts, Replacing of lubricating oil when required, Checking and adjusting contacts, Replacing fusible items, alarm etc., Re charging batteries in case of drain / and or renewing of batteries if required and Replacing/ rewinding motors if required.

1

-

-

... More
OD93740/2022-2023:Solar power generating ON Grid system 1KW. The grid connected solar PV power plant comprise of S P modules with intelligent online inverter which feeds quality AC power to electrical loads taking energy from PV and feeding the generated electricity to the grid of Distribution Licensee through net metering facility The connectivity should be as per CEA (Technical Standards for connectivity of the distributed generation resources) Regulations 2013 and KSERC (Grid Interactive Distributed Solar Energy Systems) CEA Regulations 2014 and amendments thereof if any. The system should be connected to the mains -Three phase-through a net export - import meter tested and approved by a lab approved by the Distribution Licensee. Another Energy meter (Tested in approved labs) also has to be installed between the PCU and the point of interconnection nearer to the net meter to record electricity generated from Solar power plant. The system should be connected to the mains -Three phase-through a net export - import meter tested and approved by a lab approved by the Distribution Licensee. Another Energy meter (Tested in approved labs) also has to be installed between the PCU and the point of interconnection nearer to the net meter to record electricity generated from Solar p0ower plant. Only crystalline silicon cell PV module of 380Wp or higher capacity should be used. PV modules used in power plants should be warranted for their outbreak peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. Surge protection, earthing and lightning protection to be provided as per necessary standards. Obtaining licensee from the distribution and regulatory authority will be the responsibility of the tenderer. The system should be warrantied for 5 years. Insurance premium for standard fire and special perils policy (material damage) to be provided by the bidder for 5 years.

25

-

-

... More
OD93741/2022-2023:SUPPLY OF 125 kVA DG SET WATER COOLED WITH ACOUSTIC ENCLOSURE AND STANDARD ACCESSORIES WITH FOLLOWING: Engine Make : Cummins Type of cooling : Radiator Cooled Capacity / Power : 335 BHP Starting : Electric Start, 12 V. Accessories : Silencer, etc. Alternator Make : KEL /Stamford Output : 125 kVA, Phase / Voltage : Three Phase , 415 V Class of Insulation : F/H for Stator /Rotor Type of Enclosure : IP 23 Accessories Common Base Frame Diesel Fuel Tank Starter Battery,2x 12V dry uncharged of adequate capacity with leads and terminals Anti Vibration Mounting Pads Standard Control Panel as per Kerala State Electrical Inspectorate Specifications. Acoustic Enclosure as per CPCB II norms.

1

-

-

... More
OD93743/2022-2023:Supply and erection of 160kVA, 11 kV/433 V, 3 phase, 50 Hz, copper wound lndoor type, AN Cooled, Resin cast Dry-type USS having vector group of Dyn11 with tapings +5% to -10% in steps of 2.5% consisting of HT LBS panel with provision for metering and Cable Box on LT side conforming to IS 11171. The HI panel consists of 11 kV, 630 Amps, LBSFU,HT HRC fuses of suitable ratings, Earth switch on outgoing side, ShuntTrip Coilto operate at 230V, Space Heater, Indicating Lamps, CT, PT & provision for TOD meter with required accessories.

1

-

-

... More
OD93744/2022-2023:Supply, installation,  and commissioning of 20kw power cabnet 20kw UPS with min 3 modules Three or single phase in and out with vertocal & horizondal parelleing compatibility with indoor (IP21) external isolation transformer with surge protection system , Input pf >0.99, input THDi <3 % without use of any external filters, double conversion technology with input voltage range 320-460 @ full load, 50Hz Three Phase, output 400V, 50Hz Three phase, SNMP card for network monitoring, compatibility  etc. It shall be 100% generator compatible, with Efficiency > 96% and output power factor unity ( 20kVA= 20kW), Eco mode Efficiency 98% and including all accessories etc as required.The system shall comply to IEC /EN 62040-1 and relevant IS standard. The acoustic noise at 1m of the system should be <56dB.The system shall comply to IEC /EN 62040-1, EN/IEC 62040-2, EN/IEC 62040-3, CE, PEP (ISO14025) and relevant IS standards. The system shall be true online double - conversion DSP based UPS system and also UPS shall be with automatic bypass builtin. The system shall have IGBT rectifier and inverter.

1

-

-

... More
OD93745/2022-2023:supply and installation of 12v 42ahx 40 nos for 30 min backup battery @ 20kw .8 PF load (SMF battery of reputed approved make exide/quanta), having dual battery bank with Min VAH 20160 with stand and interconnecting cables etc…

1

-

-

... More
OD93746/2022-2023:The fee to be paid to electrical inspectorate towards scrutiny & inspection, meter testing, etc (actual amount will be reimbursed on production of original documents)

1

-

-

... More
OD93747/2022-2023:Charges for preparation of Electrical/fire Drawing per A3 sheet first copy

15

-

-

... More
OD93748/2022-2023: Supply and providing 6 Kg. Dry Chemical Powder type Fire Extinguisher with hose and clamps including fixing it to wall as required.

2

-

-

... More
OD93749/2022-2023:Supply and providing 9 Litre capacity GI Fire Bucket painted in post office red with primer coat of red oxide and written with white paint 'FIRE' mounted on MS angle frame work/ wall bracket filled with fine sand, painting the bracket/ floor stand including making good the damages, colour washing etc. as required.

2

-

-

... More
OD93750/2022-2023:Supply & providing First Aid Chart duly framed and placed ina conspcious location for clear vision

1

-

-

... More
OD93751/2022-2023:Painting letters or figures of size 2.50 cm, 4 cm or 5 cm height with enamel paint as identification mark to SB, DB, panel board etc as required

400

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.