Kerala State Coastal Area Development Corporation Limited Tender

... More
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kerala State Coastal Area Development Corporation Limited - KSCADC Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date28 Jan 2025
Closing Date5 Feb 2025
Tender Amount₹ 49,75,608 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

11

-

-

... More
5.3 Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15sup0/sup landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).

20.26

-

-

... More
5.9.3 Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

84.82

-

-

... More
5.9.5Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

94.01

-

-

... More
5.9.19Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges

37.4

-

-

... More
5.22A.1Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Mild steel and Medium Tensile steel bars

2411.8

-

-

... More
2.25Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

41.53

-

-

... More
50.2.25.1Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge

30.15

-

-

... More
50.6.1.2Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.

30.34

-

-

... More
13.1.1 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

369.93

-

-

... More
13.10 15 mm cement plaster 1:3 ( 1 cement :3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall.

103.43

-

-

... More
13.16.1 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)

103.43

-

-

... More
13.43.1 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer

320.02

-

-

... More
13.83.2 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats

320.02

-

-

... More
13.46.1 Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

181.39

-

-

... More
11.41.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.

75.38

-

-

... More
11.46.2Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm

6.92

-

-

... More
9.147A.6Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Casement cum fixed panel window having both end single casement panel, middle fixed panels and at top completely fixed ventilator with S.S friction hinges (350 x 19 x 1.9) made of (big series) frame 67 x 60 mm , sash 67 x 80 mm , & mullion 67 x 80 mm all having wall thickness of 2.3 ± 0.2 mm and single glazing bead/double glazing bead of appropriate dimension. (Area of window above 3.00 sqm upto 5.00 sqm).

13.44

-

-

... More
9.147C.1Providing and fixing factory made uPVC white colour casement/ Casement cum fixed glazed door comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws, etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealent shall be paid separately). Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Casement door with 3D hinges made of (big series) frame 67 x 64 mm & sash 67 x 110 mm both having wall thickness of 2.3 +/- 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door upto 2.00 sqm).

4.2

-

-

... More
9.117.1Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1 mm), with wall thickness 2.0mm (±0.2 mm), corners of the door frame to be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 x 19 mm and 1 mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer's specification and direction of Engineer-in-chargeExtruded section profile size 48x40 mm

24

-

-

... More
9.118.1 Providing and fixing to existing door frames24 mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x24 mm and 2 mm (± 0.2 mm) wall thickness,fixed to the shutter styles by means of plastic/galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge( For W.C. and bathroom door shutter).

6.67

-

-

... More
9.48.1 Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding

134.4

-

-

... More
13.48.3 Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture

14.4

-

-

... More
Outdoor stage, Sitting area development, Boundary wall and Art work, Entrance structure and other related works

-

-

-

... More
2.8.1Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

103.38

-

-

... More
7.1.1 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)

52.6

-

-

... More
4.1.6 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)

23.12

-

-

... More
4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

21.62

-

-

... More
5.9.1 Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

235.27

-

-

... More
5.1.2 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size

6.25

-

-

... More
5.3 Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15sup0/sup landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).

10.69

-

-

... More
5.9.5Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

52.2

-

-

... More
5.9.19 Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges

7.5

-

-

... More
5.22A.1Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Mild steel and Medium Tensile steel bars

1699

-

-

... More
50.2.25.1 Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge

75.99

-

-

... More
5.5 Reinforced cement concrete work in arches, archribs, domes, vaults, shells, folded plate and roofs having slope more than 15 up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 ( 1 cement :1.5 coarse sand(Zone III) : 3 graded stone aggregate 20 mm nominal size)

6.3

-

-

... More
5.9.3Centering and shuttering including strutting, etc. and removal of form for:Suspendedfloors, roofs, landings, balconies and access platform

42

-

-

... More
50.6.1.2Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.

70.14

-

-

... More
13.1.1 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

140.27

-

-

... More
OD53837/2024-2025art/sculpture work on wall with cement mortar 1:4 including all cost of materials and labour

40

-

-

... More
13.11 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 ( 1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 ( 1 cement : 6 fine sand).

110

-

-

... More
13.46.1 Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

140.27

-

-

... More
13.45.1 Finishing walls with textured exterior pint of required shade:New work (Two or more coats applied @ 3.28 ltr/ 10 sqm ) over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm

157.5

-

-

... More
OD51716/2024-2025 Providing and laying industrial grade antiskid tiles of size 300x300mm with thickness 9mm or nearest with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colors & shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.

125.59

-

-

... More
OD10799/2024-2025 Providing and fixing internal wall panels on Light gauge steel frame work with 12mm thick fiber cement board on single face conforming to IS 14862:2000 of category III type B (High pressure steam cured) as per standard sizes fixed with self-drilling / tapingscrews / fasteners @ 60cm c/c of approved make, Screws shall be of counter sunk rib head of 1.60mm to 4 mm thick of 8 to 10 gauge of length varying from 25 to 45 mm. Proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish.

36

-

-

... More
OD10801/2024-2025 Engaging Carpenter (Average)

25

-

-

... More
OD10802/2024-2025 engaging painter for artist work

25

-

-

... More
50.10.1 Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete

212.5

-

-

... More
13.48.3 Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture

17.2

-

-

... More
OD10804/2024-2025 Providing and fixing Sign board with 4mm thick ACP board of size 1200mmx750mm and letters using 18mm thick multi-wood fixed with mirror screws etc. attached to 80mm dia “B” Class GI Pipe post etc. complete all as per the design approved by the engineer in charge.The work includes (ACP = 1.20 x 0.75 x 1.05 = 0.945m2,Excavation = 0.60 x 0.60 x 0.60 =0.216m3,Concrete = 0.60 x 0.60 x 0.60 = 0.216m3,Steel bar = 2 x 0.30 x 0.888 = 0.532Kg,Length of Pipe = 4.05m,Length of Painting Pipe = 4.05m) etc

2

-

-

... More
OD43832/2024-2025 Engaging Coolie.

10

-

-

... More
OD51694/2024-2025 Providing and fixing pre coated -Aluzinc profiled sheet (truss-less) size, shape, and pitch approved by engineer in charge 0.50mm (+-0.05%) total coated thickness with zinc coating 170 grams/sqm as per IS:277, in 550mpa steel grade 6-8 microns epoxy primer on both side ofthe sheet and polyester top coated 17-20 microns sheet should have protection film to avoid scratching during transportation and should be supplied in single length up to 22 m or as desired by engineer in charge.pressure equalization, providing suitable gutter profiles at bottom (if required). This item includes cost of all inputs of designing,labour for fabricating and installation required sizes and required numbers etc.complete. Installation of scaffolding and other incidental charges including wastage etc., enabling services, cranes or cradles etc. as described above and as specified.154.32 m2 sheet required for 131.25 m2 actual area of roof. Truss-less roof

78.5

-

-

... More
Appendix B:Electrification

-

-

-

... More
1.10.3 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C

20

-

-

... More
1.33 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden blockincluding connection etc as required

20

-

-

... More
1.17.3 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm

140

-

-

... More
90.1.1.1 Supply and laying medium gauge PVC conduit of the following sizes conforming to IS 9537/1983 Part III in roof slab, jointing the pipes with PVC solvent cement, tying & fixing the conduit firmly with the reinforcement etc. as required.20 mm

20

-

-

... More
1.21.1 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

100

-

-

... More
1.21.2 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

20

-

-

... More
1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or inrecess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 ampsmodular switch, connection etc. as required. (For light plugs to be used in non residentialbuildings)

6

-

-

... More
1.56 Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings)

11

-

-

... More
1.58 Supplying and fixing PVC batten/ angle holder including connection etc. as required.

2

-

-

... More
OD59953/2024_25 Supply of exhaust fan louver for the following size on the existing exhaust fan, indoor/outdoor usage, silver colour, adjustable, frame made with galvanized sheet and flappers made up with aluminium. (Make must be approved by CPWD/KPWD/KSCADC)450mm.

2

-

-

... More
OD59959/2024_25Supply of 450 mm sweep, 1400 rpm Heavy Duty Exhaust fan working on 230 V A/C for site

2

-

-

... More
OD59963/2024_25 Supply and Fixing of Bulk Head includig 9 w LED

4

-

-

... More
OD59964/2024_25 Supply, installation and commissioning of 9W, 240V LED Bulb (PWD approved make)

2

-

-

... More
90.3.19.3 Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required1200 mm 1X20W LED Lamp with box type fixture

11

-

-

... More
90.4.1 Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.

1

-

-

... More
90.4.5.2 Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required.1200mm sweep -5star rated ceiling fan complete with 300mm down rod , canopies, shackles and blades working on 230V/240V single phase A/C

1

-

-

... More
1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 1 1

1

-

-

... More
90.15.4.2 Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)

2

-

-

... More
2.3.3 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door

1

-

-

... More
2.10.1 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breakersuitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

8

-

-

... More
OD59949/2024_25 Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB/enclosure complete with connections, testing and commissioning etc. as required.br25A

1

-

-

... More
2.14.1 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps

1

-

-

... More
OD59939/2024_25 Supply and fixing of ferrules on wire for circuit identification, as required (Any make approved by CPWD/KPWD/KSCADC)br1.5 to 2.5sqmm wire

60

-

-

... More
OD59940/2024_25 Supply and fixing of connector bar (including connection of wires 1 to 1.5sqmm) for loop circuit connections or as required in an establishment of circuit connection (Any make approved by CPWD/KPWD/KSCADC)br6mm

40

-

-

... More
Open Stage, Wall and Gate

-

-

-

... More
1.33 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden blockincluding connection etc as required.

5

-

-

... More
90.1.1.1 Supply and laying medium gauge PVC conduit of the following sizes conforming to IS 9537/1983 Part III in roof slab, jointing the pipes with PVC solvent cement, tying & fixing the conduit firmly with the reinforcement etc. as required.20 mm

10

-

-

... More
1.17.3 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm

15

-

-

... More
OD59938/2024_25 Supply and installation of weather proof 6way Distribution Board with P E and N terminal, DIN rail, transparent door, cable entry cover, blanking strips for unused DIN rail openings, IP-65 and IK-08. Grey Colour. (Model Hensel KV 6106 06 Module IP65 Distribution Board or equivalent make approved byCPWD/KPWD/KSCADC)

1

-

-

... More
OD59941/2024_25 Supply and installation of weatherproof 12way Distribution Board with P E and N terminal, DIN rail, transparent door, cable entry cover, blanking strips for unused DIN rail openings, IP-65 and IK-08. Grey Colour. (Model Hensel KV 9112 M 12 Module IP65 Distribution Board or equivalent make approved by CPWD/KPWD/KSCADC)

1

-

-

... More
2.10.1 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc as required single pole

10

-

-

... More
2.14.1 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps

1

-

-

... More
OD59949/2024_25 Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB enclosurecomplete with connections, testing and commissioning etc. as required.br25A

1

-

-

... More
OD59952/2024_25 Supply, Fixing and commissioning of Nylon 66 cable gland for connecting cable to weather proof junction box with IP68 for cable diameter 6mm to 12mm, including lock nut. Low Smoke Zero Halogen (LSZH) gland (Make: Hellermann Tyton or approved items by KSCADC/PWD)

24

-

-

... More
OD59956/2024_25 Supply, Fixing and Commissioning of waterproof junction box with IP68 and connectors in ABS material, square and rectangle shape. Including all mounting accessories (Make: Hensel or any approved make by KSCADC/PWD)

12

-

-

... More
OD59957/2024_25 Supply and installation of waterproof enclosure (Gang box/switch box) with 10Nos. of 6A switch and 1 No. of 6A socket suitable for the enclosure (Make should be approved by CPWD/KPWD/KSCADC) - 12 Module

2

-

-

... More
OD59962/2024_25 supply of of 7/8/9w Round shaped recess LED down Lighter: Supply and providing round shaped 7/8/9W low glare, recess mounting type, integral LED down light fittings with while powder coated Die cast aluminium body with etc as required

5

-

-

... More
OD59967/2024_25 Supply of high performance portable desert air cooler with wood wool cooling pads (High density honey comb pads), 4 way air deflection, 3-way speed settings for air speed control, Capacity 55 L; Air delivery 4250 CMH; Air throw 52 ft.; Power 190 W; Operating voltage 230 V; Suitable for up to 550 sq. ft, Motorized and auto-swing louvres for 4-way air deflection; Water level indicator for easy monitoring, Relatively lower power requirement; Can run on inverter power, Rust-free body with smooth, easy to clean exteriors (Model:- Crompton ozone 55 desert cooler or equivalent make approved by CPWD/ KPWD/ KSCADC)

2

-

-

... More
OD59968/2024_25 Supplying and fixing suitable size Weather proof box 25A 3 pin plug socket with double pole switch for car chargingbrsocket including metal box with IP65 protection etc. complete

2

-

-

... More
90.12.1.12 Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3 core 4 sq mm

80

-

-

... More
90.12.5.12 Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3 core 4 sq mm

10

-

-

... More
90.12.6.12 Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3 core 4 sq mm

3

-

-

... More
90.12.7.12 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3 core 4 sq mm with factory made clamp

20

-

-

... More
90.12.1.13 Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3 core 6 sq mm

60

-

-

... More
90.12.5.13 Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3 core 6 sq mm

10

-

-

... More
90.12.6.13 Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3 core 6 sq mm

3

-

-

... More
90.12.7.13 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3 core 6 sq mm with factory made clamp

20

-

-

... More
90.12.10.2 Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size

100

-

-

... More
90.16.2.4 Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.40 mm dia G.I. pipe ( medium class)

20

-

-

... More
OD59977/2024_25 Supply and fixing of flood light IP66 rated with pressure die-cast aluminium housing with high impact resistance (IK07) glass cover and high-power single die ceramic base LEDS and unique optics ensuring uniform distribution. (Make Philips: BVP120 LED047 CW FLNB FG A1 PSU GR or equivalent make approved by CPWD/KPWD/KSCADC)

8

-

-

... More
OD59978/2024_25 Supply and fixing two-way wall washer light 10W, IP65 rated, warm light (Philips 582061 or equivalent make approved by CPWD/KPWD/KSCADC)

2

-

-

... More
90.15.4.3 Supply Conveyance, installation, testing and commissioning of 70W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than 10%, power factor greater than 0.98,RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)

6

-

-

... More
OD59980/2024_25 Supply and fixing of high-grade factory-made metal plate type Foundation bolt and nut suitable for mounting 8M long octagonal pole on foundation (Make: - Tata or equivalent make approved by CPWD/KPWD/KSCADC)

24

-

-

... More
OD59981/2024_25 Supply and Fixing of high quality 8 metre long Octagonal GI pole for mounting street lights in grey colour on the existing foundation with foundation bolt (Make: Tata or equivalent make approved by CPWD/KPWD/KSCADC)

6

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.