Kerala State Coastal Area Development Corporation Limited Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 42,500Document Cost
₹ 2,950Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_SCADC_730432_2Tender No
ET-66/2024-25Tender Authority
Kerala State Coastal Area Development Corporation Limited ViewPurchaser Address
-Website
http://etenders.kerala.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
15.7.4
Demolishing brick work manually / by mechanical means including stacking of
serviceable material and disposal of unserviceable material within 50 metres lead as
per direction of Engineer-in-Charge.In cement mortar
2.81
-
-
... More
OD37492/2024-2025
Chipping and removing top of RCC column to lines and levels carefully with out
damaging the remaining portion and removing debris Up to a distance of 150 m
including labor charges and levelling etc. complete as per the directions of deptl.
Officers at site.
0.11
-
-
... More
5.3
Reinforced cement concrete work in beams, suspended floors, roofs, having slope up
to 15sup0/sup landings, balconies, shelves, chajjas, lintels, bands, plain window
sills, staircases and spiral stair cases up to floor five level excluding the cost of
centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse
sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
27
-
-
... More
5.9.3
Centering and shuttering including strutting, etc. and removal of form for:Suspended
floors, roofs, landings, balconies and access platform
180.41
-
-
... More
5.9.5
Centering and shuttering including strutting, etc. and removal of form for:Lintels,
beams, plinth beams, girders bressumers and cantilevers
47
-
-
... More
5.22A.6
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing
in position and binding all complete above plinth level.Thermo - Mechanically
Treated bars of grade Fe-500D or more
2850
-
-
... More
50.6.1.2
Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm
or nearest available size confirming to IS 2185 part I of 1979 for super structure up to
floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc
complete.
7
-
-
... More
13.1.1
12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
58
-
-
... More
13.10
15 mm cement plaster 1:3 ( 1 cement :3 coarse sand) finished with a floating coat of
neat cement on the rough side of single or half brick wall.
185
-
-
... More
13.16.1
6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
170
-
-
... More
13.43.1
Applying one coat of water thinnable cement primer of approved brand and
manufacture on wall surface:Water thinnable cement primer
270
-
-
... More
13.46.1
Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two
or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior
primer applied @ 2.20 kg/10 sqm)
90
-
-
... More
13.83.2
Wall painting with premium acrylic emulsion paint of interior grade, having VOC
(Volatile including applying additional coats wherever required to achieve even shade
and colour.Two coats
200
-
-
... More
Renovation of existing Toilet block
-
-
-
... More
15.2.2
Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal
concrete 1:4:8 leaner mix ( including equivalent design mix)
1.16
-
-
... More
2.8.1
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means
in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),
including dressing of sides and ramming of bottoms, lift up to 1.5 m, including
getting out the excavated soil and disposal of surplus excavated soil as directed,
within a lead of 50 m.All kinds of soil
30
-
-
... More
2.16.1
Close timbering in trenches including strutting, shoring and packing cavities
(wherever required) complete (Measurements to be taken of the face area
timbered).Depth not exceeding 1.5m
33.82
-
-
... More
4.1.8
Providing and laying in position cement concrete of specified grade excluding the
cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4
coarse sand : 8 graded stone aggregate 40 nominal size)
4
-
-
... More
50.6.1.2
Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm
or nearest available size confirming to IS 2185 part I of 1979 for super structure up to
floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc
complete
7
-
-
... More
5.2.2
Reinforced cement concrete work in walls (any thickness), including attached
pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,
abutments, posts and struts etc. up tot floor five level excluding cost of centering,
shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded
stone aggregate 20 mm nominal size)
2.63
-
-
... More
5.9.3
Centering and shuttering including strutting, etc. and removal of form for:Suspended
floors, roofs, landings, balconies and access platform
10
-
-
... More
5.22A.6
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing
in position and binding all complete above plinth level.Thermo - Mechanically
Treated bars of grade Fe-500D or more
350
-
-
... More
13.10
15 mm cement plaster 1:3 ( 1 cement :3 coarse sand) finished with a floating coat of
neat cement on the rough side of single or half brick wall.
100
-
-
... More
13.1.1
12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
21.3
-
-
... More
14.1.2 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 meters lead:Cement mortar 1:4 ( 1 cement: 4 coarse sand)
15
-
-
... More
11.36
Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622
(thickness to be specified by the manufacturer), of approved make, in all colours,
shades except burgundy, bottle green, black of any size as approved by Engineer -inCharge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar
1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm,
including pointing in white cement mixed with pigment of matching shade complete.
55
-
-
... More
11.37
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be
specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved
make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick
cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with
white cement and matching pigment etc., complete.
12
-
-
... More
9.117.1
Providing and fixing factory made uPVC door frame made of uPVC extruded
sections having an overall dimension as below (tolerance ±1 mm), with wall thickness
2.0mm (±0.2 mm), corners of the door frame to be jointed with galvanized brackets
and stainless steel screws, joints mitred and plastic welded. The hinge side vertical of
the frames reinforced by galvanized M.S. tube of size 19 x 19 mm and 1 mm (± 0.1
mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as
per manufacturer's specification and direction of Engineer-in-chargeExtruded section
profile size 48x40 mm
25
-
-
... More
9.118.2
Providing and fixing to existing door frames30 mm thick factory made Polyvinyl
Chloride (PVC) door shutter made of styles and rails of a uPVC hollow section of
size 60x30 mm and wall thickness 2 mm (± 0.2 mm), with inbuilt decorative
moulding edging on one side. The styles and rails mitred and joint at the corners by
means of M.S. galvanised/plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting
galvanised M.S. tube of size 25x20 mm and 1 mm (± 0.1 mm) wall thickness. The
lock rail made up of 'H' section, a uPVC hollow section of size 100x30 mm and 2 mm
(± 0.2 mm) wall thickness fixed to the shutter styles by means of plastic/galvanised
M.S. 'U' cleats. The shutter frame filled with a uPVC multi-chambered single panel of
size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm)
wall thickness. The panels filled vertically and tie bar at two places by inserting
horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete
as per manufacturer's specification and direction of Engineer-in-charge.
7.88
-
-
... More
50.9.1.2
Providing wood work in frames of doors, windows, clerestory windows and other
frames, wrought framed and fixed in position with hold fast lugs or with dash
fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for
separately) using good quality Pincoda wood
0.07
-
-
... More
9.48.2
Providing and fixing M.S. Grills of required pattern in frames of windows etc. with
M.S. flats, square or round bars etc. including priming coat with approved steel
primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc
6.75
-
-
... More
9.53
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10
mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block
30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm
nominal size)
10
-
-
... More
14.64.2
Finishing walls with water proofing cement paint of required shade:Old work ( one or
more coats @ 2.20 kg/ 10 sqm ) complete
50
-
-
... More
14.65.1
Finishing walls with textured exterior paint of required shade:Old work (Two or more
coats on existing cement paint surface applied @ 3.28 ltr/10 sqm
60
-
-
... More
13.48.2
Finishing with Deluxe Multi surface paint system for interiors and exteriors using
primer as per manufacturers specifications:Painting wood work with Deluxe Multi
Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an
under coat of primer applied @ 0.75 ltr/10 sqm of approved brand and manufacture
3
-
-
... More
18.58.1.2 Providing and fixing PTMT grating of approved quality and colour.
Circular type125 mm nominal dia with 25 mm waste hole
5
-
-
... More
17.1.1
Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm
Sand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, including
flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with
all fittings and fixtures complete, including cutting and making good the walls and
floors wherever require:White Vitreous china Orissa pattern W.C. pan of size
580x440 mm with integral type foot rests
5
-
-
... More
18.51.1
Providing and fixing C.P. brass long body bib cock of approved quality conforming to
IS standards and weighing not less than 690 gms.15 mm nominal bore
5
-
-
... More
50.18.8.2.2
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00
m spacing. This includes jointing of pipes & fittings with one step PVC solvent
cement and testing of joints complete as per direction of Engineer-in-Charge.
Concealed work, including cutting chases and making good the wall etc. 20 mm pipe
10 Kgf/ cm2
7.5
-
-
... More
50.18.9.14.1
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00
m spacing. This includes jointing of pipes & fittings with one step PVC solvent
cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm
dia 10 Kgf/cm2 - External work- Exposed on wall
7.5
-
-
... More
50.18.9.6.1
Providing and fixing PVC pipes includings jointing of pipes with one step PVC
solvent cement, trenching, refilling & testing of joints complete as per direction of
Engineer in Charge. 50 mm dia 10Kgf/cm2
40
-
-
... More
50.18.8.9.1
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00
m spacing. This includes jointing of pipes with one step PVC solvent cement and
testing of joints complete as per direction of Engineer-in-Charge. Concealed work,
including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2
7.5
-
-
... More
50.18.9.9.1
Providing and fixing PVC pipes includings jointing of pipes with one step PVC
solvent cement, trenching, refilling & testing of Joints complete as per direction of
engineer in charge.110 mm dia 6Kgf/cm2
12
-
-
... More
50.18.9.22.2
Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes,
including jointing with PVC solvent cement - 110 mm dia 45 degree Elbow
10
-
-
... More
50.18.9.22.1
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,
including jointing with PVC solvent cement - 110 mm dia Elbow
2
-
-
... More
50.18.9.22.4
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,
including jointing with PVC solvent cement- 110 mm dia Bend
2
-
-
... More
50.18.9.22.5
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes
including jointing with PVC solvent cement 110x110x110 mm dia Tee
5
-
-
... More
50.18.9.22.7
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,
including jointing with PVC solvent cement - 110x110x75 mm dia Door Tee
5
-
-
... More
50.18.9.8.1
Providing and fixing PVC pipes includings jointing of pipes with one step PVC
solvent cement, trenching, refilling & testing of joints complete as per direction of
Engineer in Charge. 75 mm dia 6 Kgf/ cm2
15
-
-
... More
50.18.9.18.1
Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m
spacing. This included jointing of pipes with one step PVC solvent cement and testing
of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 -
External work- Exposed on wall
12.5
-
-
... More
50.18.9.21
Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,
including jointing with PVC solvent cement - 75 mm dia Elbow
6
-
-
... More
50.18.9.21.4
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,
including jointing with PVC solvent cement - 75 mm dia Bend
2
-
-
... More
50.18.9.21.7
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,
including jointing with PVC solvent cement - 75 mm dia Vent cowl
5
-
-
... More
50.18.9.21.3
Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes,
including jointing with PVC solvent cement -75 mm dia Door Elbow
5
-
-
... More
50.18.9.21.5
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,
including jointing with PVC solvent cement -75x75x75 mm dia Tee
5
-
-
... More
50.18.9.21.2
Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,
including jointing with PVC solvent cement -75 mm dia 45 degree Elbow
10
-
-
... More
19.7.1.1
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand)
with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate
20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8
graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with
cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat
cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4
graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat
cement complete as per standard design:
Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty)
455x610 mm internal dimensions, total weight of cover and frame to be not less than
38 kg (weigh of cover 23 kg and weight of frame 15 kg):With common burnt clay
F.P.S. (non modular) bricks of class designation 7.5
2
-
-
... More
19.33
Constructing soak pit 1.20x1.20 m filled with brickbats including S.W. drain pipe 100
mm diameter and 1.20 m long complete as per standard design.
2
-
-
... More
23.3.2
Supplying, assembling, lowering and fixing in vertical position in bore well,
unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS :
12818, including required hire and labour charges, fittings & accessories etc. all
complete, for all depths, as per direction of Engineer- in- Charge.150 mm nominal
size dia
15
-
-
... More
23.1.1.1
Boring / drilling bore well of required dia for casing / strainer pipe, by suitable method prescribed in IS: 2800 ( part I), including collecting samples from different
strata, preparing and submitting strata chart/ bore log, including hire & running
charges of all equipments, tools plants & machineries required for the job, all
complete as per direction of Engineer - in- Charge, upto 90 metre depth below ground
level.
All types of soil300 mm dia
15
-
-
... More
18.48
Providing and placing on terrace (at all floor levels) polyethylene water storage tank
:ISI 12701 marked, with cover and suitable locking arrangement and making
necessary holes for inlet, outlet and overflow pipes but without fittings and the base
support for tank.
1000
-
-
... More
Net mending Yard
-
-
-
... More
90.3.19.3
Supply conveyance, installation, testing and commissioning the light fittings of
following types made from CRCA sheet 0.5mm thickness with all accessories and
lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated
and sheathed round copper conductor flex wire or extending the original wiring and
giving connections as required1200 mm 1X20W LED Lamp with box type fixture
10
-
-
... More
90.15.4.2
Supply Conveyance, installation, testing and commissioning of 36/40W LED street
light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip
make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal
surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated
housing,acrylic cover complete with THD less than 10%, power factor greater than
0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver
compartment should be seperatly accessible for maintenance (LM 79&80
certificates from NABL accredited Third party lab to be produced mentioning chip
manufacturer)
6
-
-
... More
90.16.1.3
Supply and drawing bare earthing conductors of the following sizes along with wiring/
cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
20
-
-
... More
90.16.5.3
Supply of superior quality copper earth socket for the following size of earth
conductor including crimping etc. as required.3.15 mm (10 SWG)
10
-
-
... More
2.16
Supplying and fixing DP sheet steel enclosure on surface/ recess along with
25/32amps 240 volts "C" curve DP MCB complete with connections,
testing and commissioning etc. as required.
1
-
-
... More
5.2
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and
providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required
2
-
-
... More
1.17.3
Supplying and drawing following sizes of FRLS PVC insulated copper conductor,
single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X
1.5 sq.mm
80
-
-
... More
1.21.1
Supplying and fixing of following sizes of medium class PVC conduit along with
accessories in surface/ recess including cutting the wall and making good the same in
case of recessed conduit as required.20 mm
70
-
-
... More
1.33
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden
block including connection etc as required.
16
-
-
... More
9.1.7
Supplying and making end termination with brass compression gland and aluminium
lugs for
following size of PVC insulated and PVC sheathed / XLPE aluminium conductor
cable of 1.1 KV
grade as required.3 X 10 sq. mm (22mm)
2
-
-
... More
OD38468/2024-2025
Supply and installation of 4 sqmm to 16 sqmm. 60 mm long x 12 mm wide x 1 mm
thick Copper earthing clips (or approximate size) for single compression glands and
giving all
connections
2
-
-
... More
90.12.10.2
Supply & laying of DWC pipe in ordinary soil 0.75m below ground level
including excavation50/38 mm or nearest size
20
-
-
... More
90.12.5.14
Supply & laying of one number PVC insulated and PVC sheathed armoured
aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/
HUME / STONE WARE/ GI/ DWC pipe as required.3 core 10 sq mm
20
-
-
... More
90.12.7.14
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured
aluminium power cable, 1.1 KV grade of the following sizes using clamps noted
along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3 core 10 sq mm with factory made clamp
5
-
-
... More
90.12.6.14
Supply & laying of one No. PVC insulated and PVC sheathed armoured
aluminium power cable of 1.1 KV grade of the following sizes in the existing
masonry open duct as required.3 core 10 sq mm
4
-
-
... More
Toilet Block
-
-
-
... More
1.33
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden
block including connection etc as required.
8
-
-
... More
1.10.1
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm
FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC
conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5
sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group A
12
-
-
... More
1.58
Supplying and fixing PVC batten/ angle holder including connection etc. as required.
5
-
-
... More
1.10.2
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm
FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC
conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5
sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group B
5
-
-
... More
1.31
Supplying and fixing suitable size GI box with modular plate and cover in front on
surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket
outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be
used in non residential buildings).
2
-
-
... More
1.21.1
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in
case of recessed conduit as required.20 mm
45
-
-
... More
1.17.3
Supplying and drawing following sizes of FRLS PVC insulated copper conductor,
single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X
1.5 sq.mm
40
-
-
... More
2.16
Supplying and fixing DP sheet steel enclosure on surface/ recess along with
25/32amps 240 volts "C" curve DP MCB complete with connections,
testing and commissioning etc. as required
1
-
-
... More
2.14.2
Supplying and fixing following rating, double pole, (single phase and neutral), 240
volts, residual
current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in
the existing MCB DB complete with connections, testing and commissioning etc. as
required.40 amps
1
-
-
... More
2.3.3
Supplying and fixing following way, single pole and neutral, sheet steel, MCB
distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar,
neutral bus bar, earth bar, din bar, interconnections, powder painted including
earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
1
-
-
... More
2.10.1
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve,
miniature circuit breaker suitable for inductive load of following poles in the existing
MCB DB complete with connections, testing and commissioning etc. as
required.Single pole
8
-
-
... More
2.11
Supplying and fixing single pole blanking plate in the existing MCB DB complete
etc. as required.
1
-
-
... More
2.12.1
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing
MCB DB complete with connections, testing and commissioning etc. as required.40
amps
1
-
-
... More
5.2 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required
2
-
-
... More
90.3.19.3
Supply conveyance, installation, testing and commissioning the light fittings of
following types made from CRCA sheet 0.5mm thickness with all accessories and
lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated
and sheathed round copper conductor flex wire or extending the original wiring and
giving connections as required1200 mm 1X20W LED Lamp with box type fixture
2
-
-
... More
90.12.7.3
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured
aluminium power cable, 1.1 KV grade of the following sizes using clamps noted
along with the cables, spacing of clamps not exceeding 60cms, making good the
damages , colour washing etc. as required.2 core 10 sq mm with factory made clamp
8
-
-
... More
90.12.6.3
Supply & laying of one No. PVC insulated and PVC sheathed armoured
aluminium power cable of 1.1 KV grade of the following sizes in the existing
masonry open duct as required.2 core 10 sq mm
4
-
-
... More
90.16.1.3
Supply and drawing bare earthing conductors of the following sizes along with
wiring/ cables and giving connection as required3.15 mm copper conductor ( 10
SWG)
40
-
-
... More
90.15.4.2
Supply Conveyance, installation, testing and commissioning of 36/40W LED street
light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip
make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal
surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated
housing,acrylic cover complete with THD less than 10%, power factor greater than
0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver
compartment should be seperatly accessible for maintenance (LM 79&80
certificates from NABL accredited Third party lab to be produced mentioning chip
manufacturer)
1
-
-
... More
90.16.5.3
Supply of superior quality copper earth socket for the following size of earth
conductor including crimping etc. as required.3.15 mm (10 SWG)
10
-
-
... More
OD38594/2024-2025 Supply, installation or fixing the LED bulb (9watt, with proper lumen of 600 to 700)
in the existing angle holder or pendent light fixture.
5
-
-
... More
OD38595/2024-2025
Supply, Installation and commissioning sintex Single Phase KSEB energy meter Box
with KSEB/EB ceiling provision. and necessary suitable size for fixing single phase
energy meter , cutout fused and switch gear.
1
-
-
... More
OD38596/2024-2025
Supply, installation, testing and commissioning of exhaust fan in the existing opening
making good damage, connection, testing, commissioning etc. as required. (a) 230
mm metal body/PVC Body (Make:- reputed brands or brand approved by the site
engineer- light duty)
5
-
-
... More
OD38597/2024-2025
Supply, installation, testing and commissioning of LED Bulk head light with IP 63
protection. (Reputed brand or Brand approved by the site engineer)
4
-
-
... More
OD38598/2024-2025
Supply and providing Cable Route Marker
4
-
-
... More
OD38599/2024-2025
Supply and installation of 4 sqmm to 16 sqmm. 60 mm long x 12 mm wide x 1 mm
thick Copper earthing clips (or approximate size) for single compression glands and
giving all
connections
2
-
-
... More
9.1.2
Supplying and making end termination with brass compression gland and aluminium
lugs for
following size of PVC insulated and PVC sheathed / XLPE aluminium conductor
cable of 1.1 KV
grade as required.2 X 10 sq. mm (19mm)
2
-
-
... More
1.17.12
Supplying and drawing following sizes of FRLS PVC insulated copper conductor,
single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x
2.5 sq. mm
20
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%