Kerala State Coastal Area Development Corporation Limited Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 50,000Document Cost
₹ 2,950Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_SCADC_684420_2Bid Award Id
ViewTender No
ET-21/2024-25Tender Authority
Kerala State Coastal Area Development Corporation Limited ViewPurchaser Address
-Website
http://etenders.kerala.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
12.50 : Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
138.36
-
-
13.52.1 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
111.21
-
-
11.37 : Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.
9
-
-
od2005/2024_2025 : Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness including pointing in white cement mixed with pigment of matching shade complete.
79.37
-
-
50.12.4.1 : Providing and fixing false ceiling with 7.5 mm thick PVC plain panel board ceiling of approved quality in aluminium frame work with necessary screws etc complete (aluminium frame work shall be paid separately)
75.4
-
-
21.5 : Providing and fixing powder coated aluminium work ( minimum thickness of powder coating 50 micron) consisting of tee /angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-Charge ( level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately ).
124.02
-
-
16.70.2 : Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts , bolts and washers as required complete as per the direction of Engineer-in- charge.Made of G.I wire of dia 4 mm. PVC coated to achieve outer dia. not less than 5 mm in required colour and shade
126
-
-
21.1.1.1 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionAnodised aluminium (anodised transparent or dyed to required shade according to IS : 1868, Minimum anodic coating of grade AC 15)
162.42
-
-
21.1.2.1 : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Anodised aluminium ( anodised transparent or dyed to required shade according to IS : 1868, Minimum anodic coating of grade AC 15)
77
-
-
21.2.1 : Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side
5.4
-
-
od16079/2024_2025 : Providing and fixing Poly carbonate solid plain sheet of 2.5mm thick with suitable shade as approved by the Engineer in charge and should be supplied in a single length of 12M or as decide by the Engineer in charge. The sheets shall be fixed using self drilling/self tapping stainless steel screw of size (5.5x55 mm) with EPDM seal complete upto any pitch in horizontal/vertical/curved surface, but excluding the cost of purlins, rafters, trusses and including cutting to size shapes where ever required.
74.52
-
-
15.7.4 : Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar
0.42
-
-
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
2.5
-
-
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
0.99
-
-
50.6.1.4 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete
2.73
-
-
50.6.1.5 : Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
2.5
-
-
5.3 : Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15sup0/sup landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
0.38
-
-
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
76.8
-
-
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
1.92
-
-
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
2.02
-
-
50.6.3.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete
1.22
-
-
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
62.92
-
-
9.119 : Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wall thickness of 5 mm, made out of extruded 5 mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos. of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door fame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer's specification and direction of Engineer-in Charge.
30.6
-
-
9.120.1 : Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and sized of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC 'C' channel of size 30 mm thickness, 70 mm width out of whicj 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5mm thick, 95 mm wide PVC sheet out of which75 mm shall be tapered in 45 degree on th inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mmx2) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail. paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded /sealed to the styles & rails with 7 mm (5 mm + 2 mm ) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive etc. complete as per direction of Engineer -in-charge, manufacture's specification & drawing.30 mm thick plain PVC door shutters
10.08
-
-
11.38 : Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of Ist quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 Coarse sand), including pointing the joints with white cement and matching pigments etc., complete.
5.76
-
-
17.1.1 : Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
2
-
-
50.17.1.4 : Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge.
2
-
-
18.51.1 : Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore
2
-
-
50.18.8.4.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 10Kgf/cm2
20
-
-
50.18.8.6.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 6 kgf/cm2
20
-
-
od2538/2024_2025 : Providing and fixing wash basin with C.I. brackets, Knee operated tap, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
12
-
-
50.18.9.7.1 : Providing and fixing PVC pipes includings of pipes with one step PVC solvent cement, trenching refilling & testing of joints complete as per direction of Engineer in Charge. 63 mm dia 6Kgf/cm2
25
-
-
50.18.9.9.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2
25
-
-
50.18.9.20.1 : Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Elbow
10
-
-
50.18.9.22.1 : Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow
10
-
-
od2271/2024_2025 : Supplying and Stacking 6mm aggregate.
2.25
-
-
16.91.2 : Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.
15
-
-
13.46.1 : Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
13.5
-
-
od12314/2024_2025 : Engaging Plumber.
13
-
-
od2272/2024_2025 : Engaging Coolie.
15
-
-
Electrical maintenance works
-
-
-
1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
37
-
-
1.33 : Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block
including connection etc as required.
37
-
-
1.17.3 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
90
-
-
1.17.12 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
90
-
-
1.17.21 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
50
-
-
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
60
-
-
1.17.23 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 x 4 sq. mm
50
-
-
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
48
-
-
od16879/2024_2025 : Supply and fixing of flexible conduit of the following size, as required - 20mm
90
-
-
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
4
-
-
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
4
-
-
1.28.2 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module
4
-
-
90.10.1.3 : Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )
4
-
-
1.26 : Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
1
-
-
2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
3
-
-
2.18 : Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on
surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
1
-
-
2.19 : Supplying and fixing 20 amps 415volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top along with 20 amps "C" curve, TPMCB, in sheet enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
1
-
-
od16960/2024_2025 : Supply and fixing of limit switch with covering box. Operation Mode: ON-OFF, Current Rating: 10 Amps, Operating Voltage: 500 Volts, Contact Type: Normally Closed, Switch Type: Limit Switch, Mounting Type: Wall Mount, Approved make by CPWD/KPWD/KSCADC
4
-
-
od16961/2024_2025 : Supply of Electric Bug Zapper, Fly Catcher Machine for Indoor, Home, Office Restaurants, industries and showrooms with UV light technology to attract and trap insects effectively, Low noise operation for an undisturbed ambiance. Product Dimensions - 60 x 20 x 40 cm; 1 kg. Approved make by CPWD/KPWD/KSCADC
6
-
-
90.15.4.2 : Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
9
-
-
od16966/2024_2025 : Supply, installation and commissioning of single phase, 240V, air curtain 1M length for a height of 7feets. The impellers are of aluminium construction with forward curved blades to minimize the air cutting noise. Easy mounting arrangement with a flat frame which can be fixed on the wall by suitable coach screws. Adjustable louvers to streamline air delivery. with sturdy motors for continuous duty application. Vibration free operation. (Make: Almonard or equivalent make approved by CPWD/KPWD/KSCADC)
4
-
-
90.4.8 : Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.
7
-
-
od217906/2023_2024 : Supply and Installation of 150mm sweep Light Duty Exhaust fan in plastic body with self opening lowers working on 230V single phase A/C. (Any make approved by CPWD/KPWD/KSCADC
5
-
-
od217916/2023_2024 : Supply, installation and commissioning of Exhaust fan having 225mm sweep in plastic frame body working on 240V AC supply on wall, giving proper connection and dressing of the cable with all necessary accessories.
2
-
-
od217908/2023_2024 : Supply and fixing Bulk-head light fittings of reputed company make, with clear/froasted glass cover, pvc base suitable for 9 watt LED bulb,including bulb, and giving all connection with suitable three core wire etc. complete.
10
-
-
90.4.9 : Charges for cutting holes suitable for accommodating exhaust fans above 305mm sweep and up to 450mm sweep including plastering colour washing etc. as required.
3
-
-
od217910/2023_2024 : Supply of 450 mm sweep, 1400 rpm Heavy Duty Exhaust fan working on 230 V A/C for site
3
-
-
od16574/2024_2025 : Supply and providing First Aid Box with first aid medicines and accessories. Color: Red & White, Size:11Inch * 13 Inch * 3 Inch (W x D x H). Made from galvanize Metal with 7 Way Processed Powder Coating for Long Lasting. Front Heavy Clear acrylic. 4 Partition for medicines organize with lock and 2 set of key. Top side handle for carry to any where and also Wall Mountable.
2
-
-
od16575/2024_2025 : Supply of exhaust fan louver for the following size on the existing exhaust fan, indoor/outdoor usage, silver colour, adjustable, frame made with galvanized sheet and flappers made up with aluminium. (Make must be approved by CPWD/KPWD/KSCADC) 450mm.
9
-
-
od16576/2024_2025 : Supply of premium quality range of Electrical Rubber Hand Gloves (Left and Right Hand) (1100V) that is suitable to be used by electricians and supervisors for protection against electrical shocks in various places like hospitals, amusement parks, water plants, office buildings, manufacturing plants and schools. Made with high quality rubber. Having excellent grip, water resistance, high strength, lightweight and high durability. (Make:- RPES or equivalent make approved by CPWD/KPWD/KSCADC)
1
-
-
od16577/2024_2025 : Supply of LED recessed mount 600mmx600mm luminaire having power consumption not more than 33W and light output not less than 3600Lumens with system efficacy >120Lumen/Watt. Luminaire housing shall be made from single piece CRCA body without welding to avoid RUSTING and PRISMATIC DIFFUSER to reduce glare. The luminaire should be should be having minimum 50000 burning hours (L70B50) with CRI≥80, SDCM<5 and co-related colour temperature (CCT) of 650K. The luminaire must have 4kV surge protection integrated in driver, ripple<5%, UGR<19, PF≥0.95, Total Harmonic Distortion THD≤10%, EMI/EMC compliant and operating voltage range 140-270V with high voltage cut off @325±15V with auto restart feature, luminaire and driver shall be separately BIS approved of same make equivalent to Philips/kesslec/osram. LM80, LM79, Type test certificate and BIS certificate need to be submitted for approvals. (Make: Philips or equivalent make approved by CPWD/KPWD/KSCADC)
65
-
-
od16578/2024_2025 : Supply and installation of Hexa style 8W Down lighter (Cool Day Light), Cutout - 4 Inch | Panel Light For False Ceiling(Poly carbonate) (Make: Philips or equivalent make approved by CPWD/KPWD/KSCADC
5
-
-
od17018/2024_2025 : Dismantling of ceiling/exhaust fan and painting the same with one or more coats of spray painting with synthetic enamel paint of approved brand and manufacture to give an even shade, including cleaning of surface with detergent and replacing the damaged rubber reel, nuts and bolts with washers and safety pins reinstalling the same as required.
5
-
-
od17019/2024_2025 : Labour charges for Re-Fixing and installation of 6-way TPN DB (including fixing of MCBs, isolator and RCCB) in recess including dressing the wires and cables and connecting the terminals with the MCB, isolator and RCCB. Including charges for cutting the hole
1
-
-
od16584/2024_2025 : Supply of Cable Tie
50
-
-
od16585/2024_2025 : Supply and providing First Aid Chart duly framed and placed in a conspicuous location for clear vision.
1
-
-
od16587/2024_2025 : S/F DCP fire extinguisher (5Kg): supply and installation of 5kg Dry chemical power type (DCP) fire extinguishers having ISI mark along with mounting supports etc.as required.
4
-
-
od16589/2024_2025 : Providing and Fixing of Electrical ISI<br>Grade Rubber Mat suitable for 440Volts<br>Switchboards.
2
-
-
od16590/2024_2025 : Provide and Fixing of 2 Nos fire buckets<br>along with stand painted with enamel<br>paint of red colour.<
1
-
-
od16595/2024_2025 : GENERAL PURPOSE LUMINAIRES. Supplying and fixing following SLEEK RD- surface mounted or recessed Round or Square Down light 112545 BGSLO Sleek surface 18W WH RD cool white LED down light fo soft diffused lighting complete light out put on ceiling / wall including connection with 1sq.mm FRLS PVC insulated copper conductor multi stranded three core cable etc as required (Make Philips,Crompton Greeves.)testing and commissioning
10
-
-
od217949/2023_2024 : Checking circuit continuity for cables, wires and proper earthing continuity, checking and testing of electrical installations, dismantling of faulty electrical installations with all required safety measures and re-checking the functionality of all electrical installations
6
-
-
od31955/2024_2025 : Supply and fixing of UV - C (UV Light) upper air disinfection system, Ceiling mounted. Optimized for low ceiling heights, the UV-C rays are distributed at device level and above. Shortwave UV radiation peak at 237.7nm (UV-C). *Louvres and reflector control the distribution of UV-C at the device level and above, WHERE PEOPLE ARE NOT USUALLY PRESENT. Complies with IEC 62471 standard for PHOTOBIOLOGICAL safety. Typically required for 20sqM area. TUV lamps included 4x9W. Recommended by WHO for prevention and control of Tuberculosis. Like Philips UV-C disinfection upper air ceiling mounted and so and so.