Kerala State Coastal Area Development Corporation Limited Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kerala State Coastal Area Development Corporation Limited - KSCADC Tender

Works
Civil And Construction
Eprocure
Opening Date4 Dec 2024
Closing Date13 Dec 2024
Tender Amount₹ 23,80,202 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
1.33Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.

216

-

-

... More
1.55.3Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C

15

-

-

... More
Sub Circuit Wiring

-

-

-

... More
1.17.3Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm

800

-

-

... More
1.17.12Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm

100

-

-

... More
1.17.21Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm

400

-

-

... More
1.17.31Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 6 sq. mm

20

-

-

... More
OD24402/2024-2025Supply and fixing of connector bar (including connection of wires 4 to 10sqmm) for loop circuit connections or as required in an establishment of circuit connection (Any make approved by CPWD/KPWD/KSCADC) 16mm

100

-

-

... More
OD24403/2024-2025Supply and fixing of connector bar (including connection of wires 2.5sqmm) for loop circuit connections or as required in an establishment of circuit connection (Any make approved by CPWD/KPWD/KSCADC) 10mm

20

-

-

... More
OD24404/2024-2025Supply and fixing of connector bar (including connection of wires 1 to 1.5sqmm) for loop circuit connections or as required in an establishment of circuit connection (Any make approved by CPWD/KPWD/KSCADC) 6mm

500

-

-

... More
OD24405/2024-2025Supply and fixing of ferrules on wire for circuit identification, as required (Any make approved by CPWD/KPWD/KSCADC) 6sqmm wire

20

-

-

... More
OD24406/2024-2025Supply and fixing of ferrules on wire for circuit identification, as required (Any make approved by CPWD/KPWD/KSCADC) 4sqmm wire

100

-

-

... More
OD24407/2024-2025Supply and fixing of ferrules on wire for circuit identification, as required (Any make approved by CPWD/KPWD/KSCADC) 1.5 to 2.5sqmm wire

300

-

-

... More
Networking

-

-

-

... More
1.27.1Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)

4

-

-

... More
1.53.1Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable

35

-

-

... More
OD24408/2024-2025Supply of Wireless Fiber Router (Black, Dual Band) with 2 External Dual Band Antennas, Easy Remote Management. Superfast Dual Band Wi-Fi ---- Up to 1.2Gbps Wi-Fi speed, 300Mbps 2.4GHz, 867Mbps 5GHz Full Gigabit Port ---- Up to 10x faster than standard Ethernet, deliver lightning-fast wired performance Supports VOIP Calls ---- Simply make or receive phone calls over the Internet Easy Remote Management ---- Supports the ONT Management and Control Interface (OMCI), easy to configure and manage remotely from an OLT Smooth Connection ---- Supports VLAN, 802.1q, smooth network connection for IPTV and other services (Make: DLink, TPLink... or equivalent make approved by CPWD/KPWD/KSCADC)

1

-

-

... More
OD24409/2024-2025Supply, crimping, fixing and installation of RJ45 Connector Module Plugs. (Make: D-Link or equivalent make approved by CPWD/KPWD/KSCADC)

4

-

-

... More
OD24410/2024-2025Supply, Installation and Commissioning of RJ 45 CAT 6 Socket modular type, on existing GI/PVC box with cover and base plate (Make: Elleys, Legrand, Indoasian or any equivalent make approved by KPWD/CPWD/KSCADC)

4

-

-

... More
Conduits

-

-

-

... More
1.21.1Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

900

-

-

... More
1.21.2Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

300

-

-

... More
1.21.4Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.40 mm

50

-

-

... More
OD24411/2024-2025Supply and fixing of flexible conduit of the following size, as required - 20mm

100

-

-

... More
Switches and Sockets

-

-

-

... More
1.24.1Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch

23

-

-

... More
1.24.4Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet

23

-

-

... More
1.24.3Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch

7

-

-

... More
1.24.5Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet

7

-

-

... More
1.28.1Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module

12

-

-

... More
1.28.2Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module

5

-

-

... More
1.28.3Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.4 Module

11

-

-

... More
1.28.4Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module

2

-

-

... More
1.28.5Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.8 Module

2

-

-

... More
1.31Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).

34

-

-

... More
1.32Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.

30

-

-

... More
1.56Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).

51

-

-

... More
1.57Supplying & fixing suitable size Gl box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required. lCD

2

-

-

... More
2.16Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.

6

-

-

... More
2.17Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32amps 415 volts "C" curve TP MCB complete with connections, testing and commissioning etc. as required.

2

-

-

... More
90.10.1.2Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )2 module moulded plastic box on surface

12

-

-

... More
90.10.1.3Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )3 module moulded plastic box on surface

4

-

-

... More
90.10.1.4Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )4 module moulded plastic box on surface

5

-

-

... More
90.10.1.5Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )6 module moulded plastic box on surface

2

-

-

... More
90.10.1.6Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )8 module moulded plastic box on surface

2

-

-

... More
90.10.3.15Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator

21

-

-

... More
90.10.3.32Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3 pin plug top with indicator

21

-

-

... More
90.10.3.33Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket

21

-

-

... More
90.9.2.1Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.100 x 50 mm CMS with base and lid

10

-

-

... More
90.9.2.3Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.External angle 90 degree

1

-

-

... More
90.9.2.5Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Internal angle 90 degree

1

-

-

... More
90.9.2.8Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.End cap

2

-

-

... More
90.9.2.12Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.1 to 3 module mounting box

11

-

-

... More
90.9.2.13Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.4 to 5 module mounting box

4

-

-

... More
1.27.1Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module(75mmX75mm)

4

-

-

-

-

-

... More
2.3.3Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door

2

-

-

... More
2.3.4Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator16 way, Double door

1

-

-

... More
2.10.1Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

117

-

-

... More
2.11Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

66

-

-

... More
OD24641/2024-2025Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB/enclosure complete with connections, testing and commissioning etc. as required (Approved make by CPWD/KPWD/KSCADC). 25A

1

-

-

... More
2.12.1Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

2

-

-

... More
2.13.1Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

9

-

-

... More
2.14.1Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps

1

-

-

... More
2.14.2 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

2

-

-

... More
2.15.2 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

9

-

-

... More
2.23.4Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with testing and commissioning etc. as required. 2For 14 way, Double door SPN MCBDB

3

-

-

... More
2.24.1Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 4 way, Double door TPN MCBDB

8

-

-

... More
2.24.2Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 6 way, Double door TPN MCBDB

8

-

-

... More
2.24.3Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 8 way, Double door TPN MCBDB

2

-

-

... More
2.25Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for tripple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.

4

-

-

... More
90.11.1.10Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)

4

-

-

... More
90.11.1.11Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43)

4

-

-

... More
90.11.1.12Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - three phase double cover (IP 42/43)

1

-

-

... More
OD24643/2024-2025 Supply and fixing of Cable Zip Ties, White (100 mm x 2.5 mm,4" inch) Multi Purpose Self-Locking Nylon Teeth Grip Cable Ties Cord Management Ties, Plastic Ties for cables, industries, Workshop.

700

-

-

... More
90.14.10.3 Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 16 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL

1

-

-

... More
90.11.1.19 Supply and installation of sheet steel, phosphatised and painted, dust and verminproof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)

2

-

-

... More
2.2.14Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.125 Amp, 36 KA

1

-

-

... More
OD24666/2024-2025 Supply, installation and commission of TP, 40A, 415V MCB, 'C', curve, 10kA inside DB (Make: Legrand DX3, ABB or any equivalent make approved by KPWD/CPWD/KSADC)

9

-

-

-

-

-

... More
90.12.37.3Supply & laying of one number PVC insulated and PVC sheathed armoured copper power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).2 core 10 sq mm

15

-

-

... More
90.12.1.41 Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).4 core 16 sq mm

20

-

-

... More
90.12.5.41Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 16 sq mm

330

-

-

... More
90.12.6.3Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.2 core 10 sq mm

125

-

-

... More
90.12.6.28Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 35 sq mm

5

-

-

... More
90.12.6.30Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 70 sq mm

5

-

-

... More
90.12.40.33 Supply & laying of one No. PVC insulated and PVC sheathed armoured copper power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.4 core 10 sq mm

220

-

-

... More
90.12.6.41Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.4 core 16 sq mm

53

-

-

... More
90.12.7.3Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 10 sq mm with factory made clamp

70

-

-

... More
90.12.7.28 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp

8

-

-

... More
90.12.7.30Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 70 sq mm

8

-

-

... More
90.12.7.40Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp

100

-

-

... More
90.12.7.41Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp

30

-

-

... More
9.1.2 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm)

6

-

-

... More
9.1.21Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm)

2

-

-

... More
9.1.23Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)

2

-

-

... More
9.1.32Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)

16

-

-

... More
9.1.33Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)

2

-

-

... More
OD24738/2024-2025Supply and fixing of copper grounding clips (shim) 60 mm long x 20 mm wide x 1.20mm thick for single compression glands for cable size 25sqmm to 95sqmm

4

-

-

... More
OD24739/2024-2025Supply and fixing of copper grounding clips (shim) 60 mm long x 12 mm wide x 1 mm thick for single compression glands for 4sqmm to 16sqmm cables.

24

-

-

... More
7.10Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.

10

-

-

... More
4.1.2Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness

48

-

-

... More
90.12.9.2Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size

50

-

-

... More
OD24767/2024-2025Supply, laying and fixing of following DWC pipe on wall surface for the protection of cables with MS clamp 25x3 (painted) - 50/38mm.

9

-

-

... More
90.6.6.3Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm

100

-

-

... More
90.6.6.4Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.6 sq mm

100

-

-

... More
90.12.1.34Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3.5 core 185 sq mm

10

-

-

... More
90.12.6.34Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 185 sq mm

10

-

-

... More
90.12.7.34Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 185 sq mm

10

-

-

... More
90.12.24.2Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.4 sq mm

20

-

-

... More
90.12.24.3Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.6 Sq mm

6

-

-

... More
OD24799/2024-2025Supply of Nylon Yellow Borewell Submersible Danile Rope for hanging the submersible pump in an open/bore well. Made by Nylon braided cotton material helps it to remain extra strong at the same time being rust free. High strength and shock resistant to abrasion and deterioration UV light resistant Unaffected by hard water Minimal elongation - 20mm (Approved make by CPWD/KPWD/KSCADC)

200

-

-

... More
OD24800/2024-2025Supply and fixing of waterproof submersible tape 1inch X 1feet.

20

-

-

... More
9.1.27Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)

2

-

-

... More
90.12.1.33Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3.5 core 150 sq mm

50

-

-

... More
90.12.6.33Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 150 sq mm

6

-

-

... More
90.12.7.33Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 150 sq mm

20

-

-

... More
90.12.9.8Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench125/109 mm or nearest size

60

-

-

... More
9.1.26Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 150 sq. mm (50mm)

2

-

-

... More
90.12.10.2Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size

335

-

-

... More
Grounding

-

-

-

... More
5.4Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

4

-

-

... More
5.9Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)

120

-

-

... More
5.14Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.

0.5

-

-

... More
90.16.1.3Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)

1137

-

-

... More
90.16.5.3Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)

56

-

-

... More
90.16.3.9 Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 3 mm copper strip

96

-

-

... More
90.16.4.8Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).25 x 3 mm copper strip

20

-

-

... More
EM and Panel

-

-

-

... More
90.14.1.2 Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.<br> Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays,indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)

10

-

-

... More
90.14.2.1Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.

1

-

-

... More
90.14.3.2Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding suitable for 1.60/ 2.00 mm sheet

4

-

-

... More
90.14.4Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC)

2.5

-

-

... More
90.14.5Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board

30

-

-

... More
90.14.6Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.

305

-

-

... More
90.14.7Supply and providing copper earth bus in the panel board

105

-

-

... More
90.14.10.3Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 16 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL

1

-

-

... More
90.14.10.11Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.125A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC

1

-

-

... More
90.14.10.13Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.200A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC

3

-

-

... More
90.14.11.2MCCB AccessoriesSupply and fixing one number earth fault Relay up to 125A to 200A with CBCT.

1

-

-

... More
90.14.11.13MCCB AccessoriesSupply and fixing rotary handle, External type (including BUC handle with door interlock ) in the existing MCCB of rating up to 250 A

5

-

-

... More
OD24779/2024-2025Supply and installation of HRC Fuse Base with HRC Fuse link of the following rating on the existing panel board/Enclosure, as required. 80A

3

-

-

... More
OD24780/2024-2025Supply and installation of following rated 2 Way neutral links mounted on DMC/SMC base on panel board/enclosure, as required. 80A

1

-

-

... More
OD24781/2024-2025Supply and installation of following 2 Way neutral links mounted on DMC/SMC base in panel board/ Energy meter box. Any make approved by CPWD/KPWD/KSCADC 125A

1

-

-

... More
OD24782/2024-2025Supply and installation of following HRC fuse holder with HRC fuse link inside the panel board/Energy meter box. Any make approved by CPWD/KPWD/KSCADC 125A

3

-

-

... More
OD24783/2024-2025Supply and installation of following rating 2 Way neutral links mounted on DMC/SMC base link inside panel board/ energy meter box. Any make approved by CPWD/KPWD/KSCADC. 200A

3

-

-

... More
OD24784/2024-2025Supply and installation of following HRC fuse holder with HRC fuse link inside the panel board/Energy meter box. Any make approved by CPWD/KPWD/KSCADC 200A

9

-

-

... More
OD24796/2024-2025Supply, fixing, installation and commissioning of Three Phase multifunctional meter (MFM) in the existing panel board or as required. (Approved make by CPWD/KPWD/KSCADC)

2

-

-

... More
OD24797/2024-2025Supply, fixing and installation of LED panel board lights - Red/Green color. (Approved make by CPWD/KPWD/KSCADC)

8

-

-

... More
OD24798/2024-2025Supply, fixing and installation of Voltage Indicator 22mm LED Digital Display Voltmeter Lights 220 Volt AC RYB (RED, YELLOW, BLUE). (Approved make by CPWD/KPWD/KSCADC)

2

-

-

... More
2.21Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

2

-

-

... More
Fittings

-

-

-

... More
90.3.19.3Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required1200 mm 1X20W LED Lamp with box type fixture

83

-

-

... More
90.3.23.3Supply & installation of fittings suspended on steel chain<br> Supply, conveyance, installation, testing and commissioning the light fittings of following types made of CRCA sheet .5mm thick with all accessories and lamps etc. suspended from ceiling using 2 nos steel chain (16 SWG or nearest available size) of length not exceeding 30 cm properly hooked to steel hooks anchored to the ceiling and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200mm 1X20W LED Lamp with box type fixture

18

-

-

... More
90.4.5.4Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply

44

-

-

... More
90.4.2Supply and installation of suitable size MS belt type fan clamp fabricated from flat iron 40 x 6 mm, 150mm long x 2 Nos with M.S. rod bent to shape, neatly painted with 2 coats of enamel paint over a coat of red oxide primer as per IS 732 as required.

36

-

-

... More
OD24777/2024-2025Supply and fixing of Anchor Steel Double D-Hook Hanger (Heavy Duty) with Fasteners for Hanging Chandelier, Ceiling Fan or Jhoomer, Golden (Double D Hook). consists of 1 Pc. of D-Hook & 2 Pcs. of heavy-duty Fasteners (M10x75mm). Specially designed to hang Ceiling Fans, Jhoomer, Baby Swings, Ropes, etc. Pull out load is 75 Kgs and Jurk/Vibration load is 40 Kgs. Need to use 10 mm diameter drill bit for drilling holes on ceiling or wall to fix Fastener. The drilling depth should be greater than or equal to 65 mm. Fastener outer diameter approx. 10 mm. Approved make by CPWD/KPWD/KSCADC)

8

-

-

... More
1.25Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

44

-

-

... More
OD24763/2024-2025Supply of 150mm sweep Light Duty Exhaust fan in plastic body with self-opening lowers working on 230V single phase A/C. Approved make by CPWD/KPWD/KSCADC.

3

-

-

... More
OD24765/2024-2025Supply of Light Duty Exhaust fan in plastic body with self-opening lovers working on 230v single phase A/C - 250mm

2

-

-

... More
OD24759/2024-2025Supply and installation of 450 mm sweep, 900 rpm Heavy Duty Exhaust fan working on 230 V A/C

5

-

-

... More
90.4.8Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.

5

-

-

... More
90.4.9Charges for cutting holes suitable for accommodating exhaust fans above 305mm sweep and up to 450mm sweep including plastering colour washing etc. as required.

5

-

-

... More
90.4.10Conveyance, installation , testing and commissioning of exhaust fans of size up to 450mm in the existing opening, fixing necessary anchor bolts / bolt and nuts etc., as required including giving connections with the supplied wire along with the exhaust fan.

5

-

-

... More
90.15.4.2Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)

14

-

-

... More
1.58Supplying and fixing PVC batten/ angle holder including connection etc. as required.

4

-

-

... More
OD24766/2024-2025Supply and fixing of B22 LED Cool Day White LED Bulb - 9W. (Approved make by CPWD/KPWD/KSCADC)

18

-

-

... More
OD24760/2024-2025Supplying and fixing following SLEEK RD- surface mounted or recessed Round or Square Down light 112545 BGSLO Sleek surface 18/20W cool white LED down light for soft diffused lighting complete light out put on ceiling / wall including connection with 1sq.mm FRLS PVC insulated copper conductor multi stranded three core cable etc as required (Make Philips, Crompton Greeves or equivalent make approved by CPWD/KPWD/KSCADC) testing and commissioning

4

-

-

... More
OD24761/2024-2025Supply and installation of LED strip light/Flexible Rope Light for Indoor and Outdoor Decorations, Rope Light for False Ceiling, Balcony, Warm/White, Pack of 1 (5M length) (warm/white) with waterproof, made from silicon, good quality adaptor. (Philips or equivalent make approved by CPWD/KPWD/KSCADC)

16

-

-

... More
OD24762/2024-2025Supply of LED recessed mount 600mmx600mm luminaire having power consumption not more than 33W and light output not less than 3600Lumens with system efficacy >120Lumen/Watt. Luminaire housing shall be made from single piece CRCA body without welding to avoid RUSTING and PRISMATIC DIFFUSER to reduce glare. The luminaire should be should be having minimum 50000 burning hours (L70B50) with CRI≥80, SDCM<5 and co-related colour temperature (CCT) of 650K. The luminaire must have 4kV surge protection integrated in driver, ripple<5%, UGR<19, PF≥0.95, Total Harmonic Distortion THD≤10%, EMI/EMC compliant and operating voltage range 140-270V with high voltage cut off @325±15V with auto restart feature, luminaire and driver shall be separately BIS approved of same make equivalent to Philips/kesslec/osram. LM80, LM79, Type test certificate and BIS certificate need to be submitted for approvals. (Make: Philips or equivalent make approved by CPWD/KPWD/KSCADC)

42

-

-

... More
OD24764/2024-2025Supply and installation of LED Batten 10W, 2 feet LED lighting fixture - Mirror Lamp with extruded Aluminum heat sink, environmentally friendly, energy efficient prewired with lamp, AC 230V, ISI marked. Make: Philips model No. BN021C LED 12S-6500 or equivalent in other makes as specified in the list of manufacturers complete all as specified, approved by CPWD/KPWD/KSCADC

3

-

-

... More
OD24778/2024-2025Supply, fixing and installation of PVC Waterproof Bulkhead outdoor type with B22 Holder (Regular Pin Type) for Which LED Bulb Easily Available in Market. (Bulb not Included) Color: White (Approved make by CPWD/KPWD/KSCADC)

14

-

-

... More
1.49Numbering of ceiling fan / exhaust fan/ fluorescent fittings as required.

300

-

-

... More
1.43Providing and fixing extra conduit down rod of 20 mm dia, 2X10 cm length wiring with 2 X1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable including painting etc. as required. (Note: More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)

44

-

-

... More
Fire and Safety

-

-

-

... More
2.21Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

1

-

-

... More
OD24412/2024-2025Supply and providing First Aid Box with first aid medicines and accessories. Color: Red & White, Size:11Inch * 13 Inch * 3 Inch (W x D x H). Made from galvanize Metal with 7 Way Processed Powder Coating for Long Lasting. Front Heavy Clear acrylic. 4 Partition for medicines organize with lock and 2 set of key. Top side handle for carry to any where and also Wall Mountable.

3

-

-

... More
OD24413/2024-2025Supply of Fire Bucket Stand with 2 Bucket and sand. Material : Iron. Ring Handle Mounted

2

-

-

... More
OD24414/2024-2025Supply and laying of Checkered Electrical Rubber Mats, Thickness 6mm (Black, 1 M X 2 M) - 1 Pc/Insulating Rubber Mat, Anti – Skid, Shock Proof with excellent mechanical properties to overcome movement of breaker trolleys and associated electrical equipment such as heavy foot traffic. Ideal to use for: Sub – station, Power Transformer Rooms, LT & HT Labs, near bus bars and at ear control panels.

1

-

-

... More
OD24415/2024-2025Supply and providing laminated First Aid chart duly framed and placed in a conspicuous location for clear vision.

1

-

-

... More
OD24416/2024-2025Supply & fixing Laminated drawings of electrical lay out, schematic drawing etc on good frame work.

1

-

-

... More
OD24417/2024-2025Supply, fixing and installation of ABC Powder Type 6 Kg Fire Extinguisher (Red and Black) effective for all types of fire like Class A, B and C types of fires as well as Electrical fires and also ABC Powder Type (Stored Pressure) Fire Extinguisher, Multipurpose uses with 1 Wall Hook and 1 Discharge Pipe. ISI, ISO and CE Certified Product and Multipurpose Uses ABC Type fire extinguisher 6 Kg with 5 years Warranty. (Approved make by CPWD/KPWD/KSCADC)

3

-

-

... More
OD24418/2024-2025Supply of premium quality range of Electrical Rubber Hand Gloves (Left and Right Hand) (1100V) that is suitable to be used by electricians and supervisors for protection against electrical shocks in various places like hospitals, amusement parks, water plants, office buildings, manufacturing plants and schools. Made with high quality rubber. Having excellent grip, water resistance, high strength, lightweight and high durability. (Make: - RPES or equivalent make approved by CPWD/KPWD/KSCADC)

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.