Kerala State Beverages Corporation Limited Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Kerala State Beverages Corporation Limited - KSBC Tender
Eprocure
Opening Date23 Jan 2025
Closing Date30 Jan 2025
Tender AmountRefer Documents
Costs
EMD
₹ 50,000Document Cost
₹ 5,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_KSBC_728711_1Tender No
KSBC/4650/2024-SEC5Tender Authority
Kerala State Beverages Corporation Limited ViewPurchaser Address
-Website
http://etenders.kerala.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Billing ceiling element: Providing and fixing ceiling element using Gyproc gypsum ceiling board with necessary sections and
perimeter.The cost is inclusive of the CNC cut design
element as per the design.
110
-
-
... More
STORAGE
-
-
-
... More
Storage Racks: Providing and fixing storage racks with boxes and
partitions made of 16mm 710 BWP Marine Plywood,
finished with 1mm Merino laminate (14588 RH - Apex
Leaved Elm) and PVC edge banding applied using
automated machinery, achieving a total thickness of
34mm. The design includes painting of the back wall and
top branding areas with an approved textured leather
paint finish and brass lettering as per design. The cost
covers all necessary hardware for assembly and
installation.15mm brass tube has to be installed in eveery
rack as bottle fall protection.
600
-
-
... More
A Display Racks against glass without back panel: Providing and fixing storage racks with boxes and partitions made of 16mm 710 BWP Marine Plywood, finished with 1mm Merino laminate (14588 RH - Apex Leaved Elm) and PVC edge banding applied using automated machinery, achieving a total thickness of 34mm. The design includes top branding areas with an approved textured leather paint finish and brass lettering as per design. The cost covers all necessary hardware for assembly and installation.15mm brass tube has to be installed in eveery rack as bottle fall protection.
300
-
-
... More
Island Storage Racks: Providing and fixing storage racks with boxes and partitions made of 16mm 710 BWP Marine Plywood,
finished with 1mm Merino laminate (14588 RH - Apex
Leaved Elm) and PVC edge banding applied using
automated machinery, achieving a total thickness of
34mm. The design includes painting of the back wall and
top branding areas with an approved textured leather
paint finish and brass lettering as per design. The cost
covers all necessary hardware for assembly and
installation.15mm brass tube has to be installed in eveery
rack as bottle fall protection.
1810
-
-
... More
Beer Storage Racks(warm beer storage): Providing and fixing storage racks with boxes and partitions made of 16mm 710 BWP Marine Plywood, finished with 1mm Merino laminate (14588 RH - Apex Leaved Elm) and PVC edge banding applied using
automated machinery, achieving a total thickness of 34mm. The design includes painting of the back wall and top branding areas with an approved textured leather paint finish and brass lettering as per design. The cost covers all necessary hardware for assembly and installation.15mm brass tube has to be installed in eveery rack as bottle fall protection.
231
-
-
... More
Beer Chiller Storage Racks(beer chillers): Providing and fixing storage racks with box made of 16mm 710 BWP Marine Plywood, finished with 1mm Merino laminate (14588 RH - Apex Leaved Elm) and PVC edge banding applied using automated machinery,
achieving a total thickness of 34mm. The design includes top branding areas with an approved textured leather paint finish and brass lettering as per design. The cost covers all necessary hardware for assembly and installation.
389
-
-
... More
OTHERS
-
-
-
... More
A Fixeed Glass Partition: The partition shall consist of 10 mm thick toughened glass, fabricated as per approved design. The glass will be clear and of high quality, meeting safety standards and
ensuring durability. All edges will be machine-polished
for smoothness, and corners will be finished to eliminate
sharp edges. The glass will be installed using premiumgrade aluminum or stainless-steel fittings, such as U channels, brackets, and patch fittings, with a matte or glossy finish as specified. Silicone or EPDM gaskets will be used to create a secure, airtight seal. The partition will be fixed securely to the floor, ceiling, and adjacent walls to ensure stability. All measurements must be verified on-site by the contractor before installation to ensure a
precise fit.
420
-
-
... More
Painting: Includes surface preparation, application of primer,
putty, and multiple coats of approved paint finishes for
walls, ceilings, and other specified interior surfaces. The
scope covers all necessary materials, labor, tools, and
equipment to ensure a smooth and uniform finish as per
the approved color scheme and design. All work will
comply with relevant quality standards, ensuring
durability and aesthetics. Rates are measured per square
feet and include cleaning and final touch-ups.
6800
-
-
... More
Electrical Works: Electrical Works: Includes supply, installation, and commissioning of wiring, conduits, switches, sockets,
light fixtures, distribution boards, and earthing as per
approved layouts. All work complies with standards and
safety norms. Rates include materials, labor, necessary
chipping ,civil works and testing.The price is excluding
generator.Quantity of work has to be assessed by the
vendor as per the electrical drawing.
1
-
-
... More
Partition Works: Includes the supply and installation of partitions using gypsum board as per approved design
and specifications. The framework will be constructed
using metal or wooden sections, with proper cladding,
joints, and finishes. Rates include materials, labor, and
necessary hardware, measured in square feet (SQFT).
620
-
-
... More
Cassette AC:Includes the supply, installation, and commissioning of cassette air conditioning systems as per the approved
design and specifications. Scope includes indoor and
outdoor units, refrigerant piping, ducts, diffusers,
necessary electrical connections, and insulation for
efficient performance. Work involves testing, balancing,
and commissioning to ensure proper functioning. Rates
cover materials, labor, tools, and testing, measured per
unit or square meter as applicable, adhering to relevant
standards and safety regulations.
9
-
-
... More
Stair: Providing and fixing temporary stair using IS 710 BWP
16mm plywood for a dimension of 240 cm width and 60
cm height .consider each raiser to be 15 cm height and 30
cm thread .
1
-
-
... More
Mezzanine Floor: A temporary steel structure is to be fabricated and installed for the mezzanine floor, covering a total area of
316 sq. ft. The structure will have a height of 285 cm from
the mezzanine floor to the ceiling. The scope of work
includes the design, fabrication, and assembly of steel
framing to provide adequate support and stability for the
specified area. All steel members must be of appropriate
grade and dimensions, ensuring compliance with loadbearing requirements and safety standards. The BOQ
should also account for surface treatment, such as anticorrosion coating, and provisions for dismantling if
required. Connections, joint details, and any necessary
bracing should be specified to ensure structural integrity.
The cost of stair also needs to be considered.
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements