Kerala Rural Water Supply And Sanitation Agency Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 50,000Document Cost
₹ 5,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_KRWSA_536583_1Bid Award Id
ViewTender No
011/KRWSA/KNR/SUS/EDVK/22-23RTTender Authority
Kerala Rural Water Supply And Sanitation Agency ViewPurchaser Address
-Website
http://etenders.kerala.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply of uPVC Pipe, IS 4985: 2000 , 10kg/cm2, 32mm Dia.
200
-
-
... More
Supply of uPVC Pipe, IS 4985: 2000 , 10kg/cm2, 40mm Dia.
100
-
-
... More
Supply of uPVC Pipe, IS 4985: 2000 , 10kg/cm2, 50mm Dia.
400
-
-
... More
Supply of uPVC Pipe, IS 4985: 2000 , 10kg/cm2, 63mm Dia.
250
-
-
... More
Supply of uPVC Pipe, IS 4985: 2000 , 10kg/cm2, 75mm Dia.
300
-
-
... More
Supply of uPVC Pipe, IS 4985: 2000 , 10kg/cm2, 90mm Dia.
300
-
-
... More
Supply of uPVC Pipe, IS 4985: 2000 , 10kg/cm2, 110mm Dia.
250
-
-
... More
Supply of uPVC Pipe, IS 4985: 2000 , 8kg/cm2, 140mm Dia.
300
-
-
... More
Supply of uPVC Pipe, IS 4985: 2000 , 8kg/cm2, 180mm Dia.
850
-
-
... More
Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials).
20 mm nominal outer dia pipes.
100
-
-
... More
Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials). 25 mm nominal outer dia pipes.
200
-
-
... More
Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials).
32 mm nominal outer dia pipes.
200
-
-
... More
Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials). 40 mm nominal outer dia pipes.
100
-
-
... More
Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials) 50 mm nominal outer dia pipes.
400
-
-
... More
Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials).
63 mm nominal outer dia pipes.
250
-
-
... More
Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials).
75 mm nominal outer dia pipes.
300
-
-
... More
Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials). 90 mm nominal outer dia pipes."
300
-
-
... More
Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials).
110 mm nominal outer dia pipes.
250
-
-
... More
Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials). 140 mm nominal outer dia pipes.
300
-
-
... More
Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials).
180 mm nominal outer dia pipes.
850
-
-
... More
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating
each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :
All kinds of soil (Ref. Item No. 2.10.1 of DSR)
1089
-
-
... More
Fencing one side of trenches, 1.50 m height with two rows of 10 cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2 m intervals. (Data Prepared based on PWD SDB - Item No.1009)
2850
-
-
... More
Repair work within 1 m length in 20 mm (3/4 inch) house connections, using 25mm PE Pipe, PE80, PN16, Conforming to IS 4984: 2016 or later edition and PP PN 16 Compression specials, including trenching and refilling in all kinds of soil, hire for tools, cost of consumables and labour charges, cost of materials, including charges for lighting, watching, providing caution boards, traffic control etc. complete, but excluding the cost of cutting of concrete / tarred / bituminous roads and as per the directions of the department officers.
20
-
-
... More
Repair work for 1m to 2m length in 20mm (3/4 inch) house connections, using 25mm PE Pipe, PE80, PN16, Conforming to IS 4984: 2016 or later edition and PP PN 16 Compression specials, including trenching and refilling in all kinds of soil, hire for tools, cost of consumables and labour charges, cost of materials, including charges for lighting, watching, providing caution boards, traffic control etc. complete, but excluding the cost of cutting of concrete / tarred / bituminous roads and as per the directions of the department officers.
20
-
-
... More
Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertion etc. (the tail pieces if required will be paid separately):100 mm diameterClass I
1
-
-
... More
Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertion etc. (the tail pieces if required will be paid separately):125 mm diameterClass I
1
-
-
... More
Supply of CI Air Valve, Conforming to IS 14848 - 2000, Double Orifice Type DS2, Size 40mm.
2
-
-
... More
Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 80mm.
2
-
-
... More
Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. External work50 mm dia nominal bore
18
-
-
... More
Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. External work65 mm dia nominal bore
18
-
-
... More
Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. External work80 mm dia nominal bore
60
-
-
... More
supply 125 mm GI pipe
35
-
-
... More
"Conveying and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. but excluding cost of pipes and fittings - External work. 125 mm dia nominal bore Observed Data derived from item no.18.12 of DAR
35
-
-
... More
White washing with lime to give an even shade:New work (three or more coats)
163.43
-
-
... More
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
163.43
-
-
... More
Supplying and erection of best quality ISI market brand –open well submersible Three phase driven motor pump set working at 360 voltage (IS 14220) with bronze impeller and stainless steel shaft having minimum of 40000lph discharge against 100 m head with suitable ISI marked accessories such as starter(best quality ISI marked fully automatic electronic star delta ),main switch, fuse, capacitor, ELCB ,adequate length of best quality suitable size flat submersible cable, reflux valve, sluice valve, pressure gauge, earthing materials conforming to IS 3043/2000 as amended to date ,ammeter ,voltmeter, selector switch, flickering lamps dry running preventer cum no voltage wire, GI CL B(medium)/column hdpe pipes of suitable size and length , conveying and erecting the motor pumpset and giving all connections earthing etc as per the KSEB/EI rules and regulations .Trial run should be given for 7 days . Any documentation required for proper electric connection shall be arranged by the contractor at their own cost etc.. complete as per the directions of engineer in charge of the work
30
-
-
... More
Water quality test gov otherised agency
1
-
-
... More
name board on well and reservoir
1
-
-
... More
ELLUMANNAM WSS
-
-
-
... More
Providing and laying S & S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS : 8329:150 mm dia Ductile Iron Class K - 9 Pipes
1600
-
-
... More
Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:150 mm dia pipes
330
-
-
... More
: Providing and laying Double Flanged ( screwed / welded) Centrifugally (Spun) Cast Iron, Class B ( IS : 1536):150 mm dia C.I Double Flanged Pipe
20
-
-
... More
Labour for cutting C.I. pipe with steel saw.150 mm diameter C.I. pipe
15
-
-
... More
Testing 150mm DI/CI pipeline with potable water to the required test pressure 150 mm dia
Observed Data derived from item no.1018 of PHED DATA
1600
-
-
... More
Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:150 mm diameter pipe
8
-
-
... More
Providing and laying D.I specials of class K - 12 suitable for push - on jointing as per IS : 9523 :Upt 600 mm dia
10.2
-
-
... More
Providing and fixing C.I double acting air valve of approved quality with bolts, nuts, rubber insertion etc. complete ( The tail pieces, tapers etc. if required will be paid separately):50 mm dia
1
-
-
... More
Supply of CI Non Return Valve, Conforming to IS 5312 Part I - 1984, PN 1.0, Size 150mm.
2
-
-
... More
Fencing one side of trenches, 1.50 m height with two rows of 10 cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2 m intervals. (Data Prepared based on PWD SDB - Item No.1009)
1600
-
-
... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
6.25
-
-
... More
Supply of uPVC Pipe, IS 4985: 2000 , 10kg/cm2, 63mm Dia.
300
-
-
... More
Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials).
63 mm nominal outer dia pipes.
200
-
-
... More
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth exceeding 1.5m but not exceeding 3 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m: 1.50m to 3.0mAll kinds of soil (Ref. Item No. 2.11 of DSR)
783
-
-
... More
THONICHAL WSS
-
-
-
... More
Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tilling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured)
95
-
-
... More
12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
95
-
-
... More
White washing with lime to give an even shade:New work (three or more coats)
417.78
-
-
... More
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
417.78
-
-
... More
Supply of uPVC Pipe, IS 4985: 2000 , 10kg/cm2, 63mm Dia.
400
-
-
... More
100.98.235 : Supply of uPVC Pipe, IS 4985: 2000 , 10kg/cm2, 75mm Dia.
600
-
-
... More
Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials).
63 mm nominal outer dia pipes.
400
-
-
... More
Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials).
75 mm nominal outer dia pipes.
700
-
-
... More
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating
each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :
All kinds of soil (Ref. Item No. 2.10.1 of DSR)
225
-
-
... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :65 mm nominal bore
3
-
-
... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80 mm nominal bore
3
-
-
... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :20 mm nominal bore
3
-
-
... More
Fencing one side of trenches, 1.50 m height with two rows of 10 cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2 m intervals. (Data Prepared based on PWD SDB - Item No.1009)
1000
-
-
... More
Supplying and erection of best quality ISI market brand –open well submersible Three phase driven motor pump set working at 360 voltage (IS 14220) with bronze impeller and stainless steel shaft having minimum of 40000lph discharge against 100 m head with suitable ISI marked accessories such as starter(best quality ISI marked fully automatic electronic star delta ),main switch, fuse, capacitor, ELCB ,adequate length of best quality suitable size flat submersible cable, reflux valve, sluice valve, pressure gauge, earthing materials conforming to IS 3043/2000 as amended to date ,ammeter ,voltmeter, selector switch, flickering lamps dry running preventer cum no voltage wire, GI CL B(medium)/column hdpe pipes of suitable size and length , conveying and erecting the motor pumpset and giving all connections earthing etc as per the KSEB/EI rules and regulations .Trial run should be given for 7 days . Any documentation required for proper electric connection shall be arranged by the contractor at their own cost etc.. complete as per the directions of engineer in charge of the work
35
-
-
... More
Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5m in width as well as 10 sqm on plan including disposal of excavated earth up to 50 m and lift up to 1.5 m, disposed soil to be levelled and neatly dressed:All Kinds of soil
3.38
-
-
... More
Supplying at site:R.C.C. Standards post / struts / rails / pales of mix 1:1.5:3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 12.5 mm nominal size ) with wooden plugs or 6 mm bar nibs wherever required as per direction of Engineer-in-Charge (cost of earth works in excavation, concrete works in foundation to be paid separately)
5.06
-
-
... More
Fencing with R.C.C. post placed at required distance, embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post one side only, provided with horizontal lines and two diagonals of barbed wire weighing 9.38 kg per 100 metres (minimum), between the two posts fitted and fixed with G.I staples on wooden plugs or G.I binding wire tied to 6 mm bar nibs fixed while casting the post (cost of R.C.C. posts, struts, earth work and concrete to be paid for separately):- Payment to be made per metre cost of total length of barbed wire used .With G.I barbed wire
1500
-
-
... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
2.22
-
-
... More
Supplying and fixing Water Meter, Indian Standard, Class B, Multijet, 15mm ( 1/2 inch )<br>including the Surface box in the existing house connection and making the loop for fixing<br>the water meter - tracing, locating and exposing the service line at the required place<br>including earth work excavation, cutting and removing the service line portion and making<br>the connection functional including cost of all specials, labour charges etc complete
200
-
-
... More
Supply of CI Non Return Valve, Conforming to IS 5312 Part I - 1984, PN 1.6, Size 125mm
1
-
-
... More
Supply of CI Air Valve, Conforming to IS 14848 - 2000, Kinetic Air Valve Type DK, Size 50mm.
3
-
-
... More
Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 80mm.
1
-
-
... More
Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 100mm.
1
-
-
... More
Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 125mm.
1
-
-
... More
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
300
-
-
... More
name board on well and reservoir
1
-
-
... More
Water quality test gov otherised agency
1
-
-
... More
SWANTHANAM WSS
-
-
-
... More
Supply of uPVC Pipe, IS 4985: 2000 , 10kg/cm2, 90mm Dia.
700
-
-
... More
100.98.237 : Supply of uPVC Pipe, IS 4985: 2000 , 10kg/cm2, 110mm Dia.
300
-
-
... More
Providing and laying S & S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS : 8329:100 mm dia Ductile Iron Class K - 9 pipes
1000
-
-
... More
Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:100 mm dia pipes
210
-
-
... More
Providing and laying Double Flanged ( screwed / welded) Centrifugally (Spun) Cast Iron, Class B ( IS : 1536):100 mm dia C.I Double Flanged Pipe
10
-
-
... More
Labour for cutting C.I. pipe with steel saw.100 mm diameter C.I. pipe
10
-
-
... More
Testing 100mm DI/CI pipeline with potable water to the required test pressure 100 mm dia Observed Data derived from item no.1016 of PHED DATA
1000
-
-
... More
Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:150 mm diameter pipe
4
-
-
... More
Providing and laying D.I specials of class K - 12 suitable for push - on jointing as per IS : 9523 :Upt 600 mm dia
7.5
-
-
... More
Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials). 90 mm nominal outer dia pipes."
700
-
-
... More
Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials).
110 mm nominal outer dia pipes.
300
-
-
... More
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating
each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :
All kinds of soil (Ref. Item No. 2.10.1 of DSR)
570
-
-
... More
Fencing one side of trenches, 1.50 m height with two rows of 10 cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2 m intervals. (Data Prepared based on PWD SDB - Item No.1009)
1000
-
-
... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
1.28
-
-
... More
Supply of CI Non Return Valve, Conforming to IS 5312 Part I - 1984, PN 1.6, Size 100mm.
2
-
-
... More
Supply of CI Air Valve, Conforming to IS 14848 - 2000, Single Orifice, Small Orifice Type S1, Size 25mm.
2
-
-
... More
Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Hand Wheel PN 1.6, Size 100mm.
1
-
-
... More
Supplying and erection of best quality ISI market brand –open well submersible Three phase driven motor pump set working at 360 voltage (IS 14220) with bronze impeller and stainless steel shaft having minimum of 25000lph discharge against 120 m head with suitable ISI marked accessories such as starter(best quality ISI marked fully automatic electronic star delta ),main switch, fuse, capacitor, ELCB ,adequate length of best quality suitable size flat submersible cable, reflux valve, sluice valve, pressure gauge, earthing materials conforming to IS 3043/2000 as amended to date ,ammeter ,voltmeter, selector switch, flickering lamps dry running preventer cum no voltage wire, GI CL B(medium)/column hdpe pipes of suitable size and length , conveying and erecting the motor pumpset and giving all connections earthing etc as per the KSEB/EI rules and regulations .Trial run should be given for 7 days . Any documentation required for proper electric connection shall be arranged by the contractor at their own cost etc.. complete as per the directions of engineer in charge of the work
20
-
-
... More
Water quality test gov otherised agency
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements