Kerala Rural Water Supply And Sanitation Agency Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kerala Rural Water Supply And Sanitation Agency - KRWSA Tender

Works
Civil And Construction
Civil Works Others
Eprocure
Opening Date15 May 2023
Closing Date20 Jun 2023
Tender Amount₹ 14,10,59,403 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of uPVC Pipe, IS 4985: 2000 , 6kg/cm2, 160mm Dia.

490

-

-

... More
Supply of uPVC Pipe, IS 4985: 2000 , 6kg/cm2, 140mm Dia.

260

-

-

... More
Supply of uPVC Pipe, IS 4985: 2000 , 10kg/cm2, 140mm Dia.

343

-

-

... More
Supply of uPVC Pipe, IS 4985: 2000 , 8kg/cm2, 110mm Dia.

243

-

-

... More
Supply of uPVC Pipe, IS 4985: 2000 , 10kg/cm2, 110mm Dia.

300

-

-

... More
Supply of uPVC Pipe, IS 4985: 2000 , 6kg/cm2, 90mm Dia

600

-

-

... More
Supply of uPVC Pipe, IS 4985: 2000 , 8kg/cm2, 90mm Dia

710

-

-

... More
Supply of uPVC Pipe, IS 4985: 2000 , 10kg/cm2, 90mm Dia.

51

-

-

... More
Supply of uPVC Pipe, IS 4985: 2000 , 6kg/cm2, 75mm Dia..

600

-

-

... More
Supply of uPVC Pipe, IS 4985: 2000 , 8kg/cm2, 75mm Dia.

500

-

-

... More
Supply of uPVC Pipe, IS 4985: 2000 , 10kg/cm2, 75mm Dia.

615

-

-

... More
Supply of uPVC Pipe, IS 4985: 2000 , 6kg/cm2, 63mm Dia..

1635

-

-

... More
Supply of uPVC Pipe, IS 4985: 2000 , 8kg/cm2, 63mm Dia.

4670

-

-

... More
Supply of uPVC Pipe, IS 4985: 2000 , 10kg/cm2, 63mm Dia.

745

-

-

... More
Supply of uPVC Pipe, IS 4985: 2000 , 10kg/cm2, 50mm Dia.

3371

-

-

... More
Supply of uPVC Pipe, IS 4985: 2000 , 10kg/cm2, 40mm Dia.

5000

-

-

... More
Supply of uPVC Pipe, IS 4985: 2000 , 8kg/cm2, 40mm Dia.

5000

-

-

... More
Supply of uPVC Pipe, IS 4985: 2000 , 10kg/cm2, 32mm Dia.

26670

-

-

... More
Supply of uPVC Pipe, IS 4985: 2000 , 10kg/cm2, 25mm.

26670

-

-

... More
Supply of uPVC Pipe, IS 4985: 2000 , 8kg/cm2, 180mm Dia.

250

-

-

... More
Supply of DI K9 Pipe Conforming to IS 8329/2000, 300mm Dia.

6500

-

-

... More
Conveying & Laying of pipes

-

-

-

... More
Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials : 300 mm dia Ductile Iron Class K-9 Pipes Data derived from 18.72.19 in DAR

6500

-

-

... More
Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials : 250 mm dia Ductile Iron Class K-9 Pipes Data derived from 18.72.18 in DAR

200

-

-

... More
Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials). 200 mm nominal outer dia pipes.

124

-

-

... More
Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials). 180 mm nominal outer dia pipes.

250

-

-

... More
Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials). 160 mm nominal outer dia pipes

490

-

-

... More
Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials). 140 mm nominal outer dia pipes.

603

-

-

... More
Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials). 110 mm nominal outer dia pipes.

543

-

-

... More
Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials). 90 mm nominal outer dia pipes."

1361

-

-

... More
Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials). 75 mm nominal outer dia pipes.

1715

-

-

... More
Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials). 63 mm nominal outer dia pipe

7050

-

-

... More
Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials) 50 mm nominal outer dia pipes

3371

-

-

... More
Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials). 40 mm nominal outer dia pipes

10000

-

-

... More
Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials). 32 mm nominal outer dia pipe

26670

-

-

... More
Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials). 25 mm nominal outer dia pipe

26670

-

-

... More
Providing and laying D.I Specials of Class K - 12 suitable for mechanical jointing as per IS : 9523 : Upto 600 mm dia

159.77

-

-

... More
Earth work excavation

-

-

-

... More
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil

2864.75

-

-

... More
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth exceeding 1.5m but not exceeding 3 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : 1.50m to 3.0m. Ordinary Rock.

2864.75

-

-

... More
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidatingeach deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : Hard Rock(Blasting Prohibited)

20053.21

-

-

... More
Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 m2 on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m. Medium Rock (blasting prohibited) New Data derived from Item No.2.9.3

2864.75

-

-

... More
Supply of valves

-

-

-

... More
Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 300mm

1

-

-

... More
Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 250mm

2

-

-

... More
Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 200mm

2

-

-

... More
Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 150mm

2

-

-

... More
Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 125mm

5

-

-

... More
Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 100mm

5

-

-

... More
Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 80mm

5

-

-

... More
Supply of CI Air Valve, Conforming to IS 14848 - 2000, Single Orifice, Small Orifice Type S1, Size 25mm

10

-

-

... More
Supply of CI Air Valve, Conforming to IS 14848 - 2000, Single Orifice, Small Orifice Type S1, Size 40mm

10

-

-

... More
Supply of CI Air Valve, Conforming to IS 14848 - 2000, Single Orifice, Large Orifice Type S2, Size 50mm

5

-

-

... More
Conveying and Laying of Valves

-

-

-

... More
"Conveying and fixing C.I. sluice valves (with cap) by providing complete with bolts, nuts, rubber insertions etc. excluding the cost of valve (the tail pieces if required will be paid separately) : 300 mm diameter. Class I" Data derived from item no.18.31.6.1 of DAR

1

-

-

... More
Conveying and fixing C.I. sluice valves (with cap) by providing complete with bolts, nuts, rubber insertions etc. excluding the cost of valve (the tail pieces if required will be paid separately) : 250 mm diameter. Class I" Data derived from item no.18.31.5.1 of DAR

2

-

-

... More
Conveying and fixing C.I. sluice valves (with cap) by providing complete with bolts, nuts, rubber insertions etc. excluding the cost of valve (the tail pieces if required will be paid separately) : 200 mm diameter. Class I" Data derived from item no.18.31.4.1 of DAR

2

-

-

... More
Conveying and fixing C.I. sluice valves (with cap) by providing complete with bolts, nuts, rubber insertions etc. excluding the cost of valve (the tail pieces if required will be paid separately) : 150 mm diameter. Class I" Data derived from item no.18.31.3.1 of DAR

2

-

-

... More
Conveying and fixing C.I. sluice valves (with cap) by providing complete with bolts, nuts, rubber insertions etc. excluding the cost of valve (the tail pieces if required will be paid separately) : 125 mm diameter. Class I" Data derived from item no.18.31.2.1 of DAR

5

-

-

... More
"Conveying and fixing C.I. sluice valves (with cap) by providing complete with bolts, nuts, rubber insertions etc. excluding the cost of valve (the tail pieces if required will be paid separately) : 100 mm diameter. Class I" Data derived from item no.18.31.1.1of DAR

5

-

-

... More
"Conveying and fixing C.I. sluice valves (with cap) by providing complete with bolts, nuts, rubber insertions etc. excluding the cost of valve (the tail pieces if required will be paid separately) : 80 mm diameter. Class I" Observed Data derived from item no.18.31.of DAR

5

-

-

... More
Conveying and fixing C I Single acting Air Valve of approved quality with bolts,nuts,rubber insertions etc . excluding the cost of air valve(the tail pieces if required will be paid seperately): 25 mm Single acting Air Valve Observed Data derived from item no.18.59.of DAR

10

-

-

... More
Conveying and fixing C I Single acting Air Valve of approved quality with bolts,nuts,rubber insertions etc . excluding the cost of air valve(the tail pieces if required will be paid seperately): 40 mm Single acting Air Valve Observed Data derived from item no.18.59.of DAR

10

-

-

... More
Conveying and fixing C I Single acting Air Valve of approved quality with bolts,nuts,rubber insertions etc . excluding the cost of air valve(the tail pieces if required will be paid seperately): 50 mm Double acting Air Valve Data derived from item no.18.59.1 of DAR

5

-

-

... More
House Connections

-

-

-

... More
Providing 15mm (1/2 inch) house connection with 15mm (1/2 inch) water meter from existing PVC / HDPE mains up to 110 mm dia., up to a length of 5 m using 20mm Indian Standard Class 6 uPVC pipe and uPVC / GM / Brass specials viz. brass ferrule, GM full way wheel valve, Elbow, MTA, FTA, couplers, PVC Service Saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges, including the cost of tested Class B Multijet water meter with ISI mark and weather resistant PP / PE meter box of minimum size 300mm x 200mm x 150mm, but excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers

5334

-

-

... More
Providing 15mm PVC Tap in the water meter assembly for 15mm connection, using 20mm Indian Standard Class 6 uPVC pipes and specials including cost of materials, consumables, hire charges for tools and labour charges etc. complete and as per the direction of departmental officers.

5334

-

-

... More
Supply and fixing of uPVC Pipe, IS 4985: 2000 , 6kg/cm2, 63mm Dia as stand post with an average height of 1.2m (20cm underground) for house connections with end cap

5334

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

165.62

-

-

... More
Conveying and Laying of GI pipe

-

-

-

... More
Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. External work 20 mm dia nominal bore

360

-

-

... More
Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. External work 25 mm dia nominal bore

180

-

-

... More
Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. External work 32 mm dia nominal bore

180

-

-

... More
Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. External work 40 mm dia nominal bore

160

-

-

... More
Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. External work 50 mm dia nominal bore

120

-

-

... More
Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. External work 65 mm dia nominal bore

160

-

-

... More
Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. External work 80 mm dia nominal bore

120

-

-

... More
Providing and fixing G.I. pipes (medium) complete with G.I fittings including trenching and refilling etc. External work100 mm dia nominal bore

50

-

-

... More
Providing and fixing G.I. pipes (medium) complete with G.I fittings including trenching and refilling etc. External work125 mm dia nominal bore

50

-

-

... More
Construction of valve chamber

-

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed. All kinds of soil

27.44

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed. Ordinary rock

48.02

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

6.86

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:2:4 )1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size)

10.29

-

-

... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level: 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

40.32

-

-

... More
Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal siz

13.72

-

-

... More
12 mm cement plaster finished with a floating coat of neat cement of mix: 1:4 ( 1 cement : 4 fine sand)

548.8

-

-

... More
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Mild steel and Medium Tensile steel bars

4600

-

-

... More
Centering and shuttering including strutting, etc. and removal of form for: Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

1010.8

-

-

... More
Road Restoration charge

-

-

-

... More
Cutting the bituminous / concrete roads with cutting machine for a minimum depth of 200mm along the sides of proposed alignment of the pipe to be laid without causing any damage to other utilities, including the charges for hire and conveyance of tools and plant, cost of consumables and charges for lighting, watching, ribbon fencing, caution boards, traffice diversion, and as per the direction of departmental officers etc. complete, before carrying out the demolition of bituminous / concrete road by mechanical means and carrying out the excavation

85547

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

588.92

-

-

... More
Laying of GI pipes

-

-

-

... More
Conveying and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. but excluding cost of pipes and fittings - External work. 20 mm dia nominal bore Data derived from item no.18.12.2 of DAR Data for 10 m

360

-

-

... More
Conveying and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. but excluding cost of pipes and fittings - External work. 25 mm dia nominal bore Data derived from item no.18.12.3 of DAR Data for 10 m

180

-

-

... More
Conveying and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. but excluding cost of pipes and fittings - External work. 32 mm dia nominal bore Data derived from item no.18.12.4 of DAR Data for 10 m

180

-

-

... More
Conveying and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. but excluding cost of pipes and fittings - External work. 40 mm dia nominal bore Data derived from item no.18.12.5 of DAR Data for 10 m

160

-

-

... More
Conveying and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. but excluding cost of pipes and fittings - External work. 50 mm dia nominal bore Observed Data derived from item no.18.12.6 of DAR Data for 10 m

120

-

-

... More
Conveying and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. but excluding cost of pipes and fittings - External work. 65 mm dia nominal bore Data derived from item no.18.12.7 of DAR Data for 10 m

160

-

-

... More
Conveying and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. but excluding cost of pipes and fittings - External work. 80 mm dia nominal bore Data derived from item no.18.12.8 of DAR Data for 10 m

120

-

-

... More
Conveying and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. but excluding cost of pipes and fittings - External work. 100 mm dia nominal bore Observed Data derived from item no.18.12 of DAR

50

-

-

... More
"Conveying and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. but excluding cost of pipes and fittings - External work. 125 mm dia nominal bore Observed Data derived from item no.18.12 of DA

50

-

-

... More
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work

191.89

-

-

... More
Construction of OHSR CUM SUMP - 6.00 lakh Litres capacity

-

-

-

... More
Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.

360

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

77.03

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

8.32

-

-

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level

9.99

-

-

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level

442.46

-

-

... More
Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

56

-

-

... More
Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters etc.

592.7

-

-

... More
Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

766.69

-

-

... More
Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

632.64

-

-

... More
Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts

784.87

-

-

... More
Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)

22.34

-

-

... More
12 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand)

1399.91

-

-

... More
12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)

1399.33

-

-

... More
Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm)

3023.38

-

-

... More
Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces:One coat

2799.24

-

-

... More
Lettering with black Japan pint of approved brand and manufacture

2000

-

-

... More
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipe

2473

-

-

... More
Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS :15622 (thickness to be specified by the manufacturer ) of approved make in allcolours, shades except burgundy, bottle green, black of any size as approvedby Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thickbed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cementslurry @ 3.3kg per sqm including pointing in white cement mixed with pigmentof matching shade complete

159

-

-

... More
Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete

334.5

-

-

... More
Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular /L-Type sections, made of 1.60 mm thick M.S. Sheet,joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 ( 1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

510

-

-

... More
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)

938

-

-

... More
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work

366

-

-

... More
12 mm cement plaster of mix:1:6 ( 1 cement : 6 coarse sand)

224.14

-

-

... More
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover

10.15

-

-

... More
Fixing standard steel glazed doors, windows and ventilators in walls, including fixing of float glass panes with glazing clips and special metal-sash putty of approved make, or metal beading with screws, (only steel windows, glass panes cut to size and glazing clips or metal beading with screws, shall be supplied by department free of cost.Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately

446

-

-

... More
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or mor

56999.52

-

-

... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size

14.23

-

-

... More
Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

224.14

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock

375.35

-

-

... More
Survey and Design

-

-

-

... More
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidatingeach deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil.

100.8

-

-

... More
Surveying with Electronic Total Station with single prism in normal terrain and normal traffic.

85.55

-

-

... More
Conducting field inspection, analyzing the survey results and other collected data collected during field inspection, designing the pipe line networks using the EPANET for providing hydraulically feasible FHTCs by engaging techanically qualifying experts including cost of all conveyance, hire and labour charges for computer software, printing charges etc complete.

85.55

-

-

... More
Design, analysis and all detail drawing (Plan, elevation, section, bar bending details etc) the item required for satisfactorily completion of OHSR.

600000

-

-

... More
Supply and Installation of Suitable HP (IS; 14220) Openwell centrifugal single phase electric driven motor pumpset working at 360 voltage with bronze impeller and stainless steel shaft having minimum of 41.67 lps discharge against 62m head with suitable ISI marked accessories such as starter(best quality ISI marked fully automatic electronic Star Delta ), main switch ,fuse, capacitor, ELCB, adequate length of best quality suitable size flat submerssible cable, reflux valve, sluice valve, pressure gauge, earthing materialsconforming to IS 3043/2000 as amended to date, ammeter, volt meter, selector switch, flickering lamps, dry running preventer cum no voltage wire, conveying and erecting the motor pumpset and panel board and giving all connections, earthing etc. as per KSEB/EI rules and regulations. Conveying and fixing suitable GI pipe medium pipe as suction and delivering pipes including connections with pumpset delivery to the common pumping main of suitable size using suitable T/Y connections etc. Trial run should be given for 7 days. Any documentation required for proper electric connection shall be arranged by the contractor at their own cost etc. complete as per direction of site in charge of the work.The head and discharge should be ensured by the contractor before installing the pump set at the site.

2

-

-

... More
Supplying and fixing an electromagnetic flow meter capable of measuring a flow of 20 - 40 lps conforming to protection level of IP 68 for flow sensor and IP 67 for transmitter and having accuracy level of .5% with LED/LCD display unit .The flowmwter should have the housing (flow sensor) to be made of ss 304/ carbon steel with anti corroive protection and inside inner to be made up of hard rubber or neoprene all conforming to drinking water stds.the flowmwter should be coupled with HART for data acquisition and transfer with provision for wireless transfer through GSM. the manufactures should have the caliberation stds as per ISO 17025 the product shall have the sufficient warranty provision. the flowmwter should be tested and caliberated at NABL labs and test certificate should be provided. A guarantee for 36 months shall be provided.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.