Kerala Rural Water Supply And Sanitation Agency Tender
... More
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 8,751Document Cost
₹ 700Tender Fee
Refer Documents
Summary
Sustainability Support To Pattenkunnu,neerukkumchal Dhahashamani Wsss In Puthuppady Gp
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_KRWSA_747307_1Tender No
007/ KRWSA/KNR/SE/PPDY/SUS/2024-25Tender Authority
Kerala Rural Water Supply And Sanitation Agency ViewPurchaser Address
-Website
http://etenders.kerala.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
100.98.234 : Supply of uPVC Pipe, IS 4985: 2000 , 10kg/cm2, 63mm Dia.
150
-
-
... More
100.9.4 : Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials). 40 mm nominal outer dia pipes.
50
-
-
... More
100.9.5 : Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials) 50 mm nominal outer dia pipes.
150
-
-
... More
100.9.6 : Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials).
63 mm nominal outer dia pipes.
150
-
-
... More
100.1.1 : Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating
each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :
All kinds of soil (Ref. Item No. 2.10.1 of DSR)
52.5
-
-
... More
18.19.4.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):50 mm nominal boreHorizontal
1
-
-
... More
15.2.1 : Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
1.8
-
-
... More
4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
1.2
-
-
... More
M S Ladder for tank
1
-
-
... More
50 mm pvc valve
2
-
-
... More
repair nad maintenance -puttienkunn wss in puthuppadi GP
-
-
-
... More
2.1.1 : Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5m in width as well as 10 sqm on plan including disposal of excavated earth up to 50 m and lift up to 1.5 m, disposed soil to be levelled and neatly dressed:All Kinds of soil
1.5
-
-
... More
4.1.6 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
0.3
-
-
... More
5.1.3 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
1.25
-
-
... More
5.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more
75.06
-
-
... More
60.6.1 : Laterite Masonry - Laterite masonry using neatly dressed stones of size 44cmx24cmx14cm in CM 1:6 including all cost of conveyance and labour charges etc. complete.
1.2
-
-
... More
50.6.1.3 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure above floor two level up to floor V level thickness 20cm and above in: CM 1:6 ( 1 cement :6 coarse sand) etc complete
1.8
-
-
... More
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
33.42
-
-
... More
13.37.1 : White washing with lime to give an even shade:New work (three or more coats)
97.99
-
-
... More
13.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
97.99
-
-
... More
od47121/2024_2025 : Supplying and fixing Water Meter, Indian Standard, Class B, Multijet, 15mm ( 1/2 inch )<br>including the Surface box in the existing house connection and making the loop for fixing<br>the water meter - tracing, locating and exposing the service line at the required place<br>including earth work excavation, cutting and removing the service line portion and making<br>the connection functional including cost of all specials, labour charges etc complete
17
-
-
... More
12.1.3 : Providing corrugate G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete ( up to any pitch in horizontal / vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.0.63 mm thick with zinc coating not less than 275 gm/m2
7.07
-
-
... More
Supplying and erection of best quality ISI market brand –open well submersible Three phase driven motor pump set working at 360 voltage (IS 14220) with bronze impeller and stainless steel shaft having minimum of 5000 lph discharge against 70 m head with suitable ISI marked accessories such as starter(best quality ISI marked fully automatic electronic star delta ),main switch, fuse, capacitor, ELCB ,adequate length of best quality suitable size flat submersible cable, reflux valve, sluice valve, pressure gauge, earthing materials conforming to IS 3043/2000 as amended to date ,ammeter ,voltmeter, selector switch, flickering lamps dry running preventer cum no voltage wire, GI CL B(medium)/column hdpe pipes of suitable size and length , conveying and erecting the motor pumpset and giving all connections earthing etc as per the KSEB/EI rules and regulations .Trial run should be given for 7 days . Any documentation required for proper electric connection shall be arranged by the contractor at their own cost etc.. complete as per the directions of engineer in charge of the work
5
-
-
... More
Name Board
1
-
-
... More
water uality test
1
-
-
... More
MS Gate for source
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%