Kerala Road Fund Board Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kerala Road Fund Board - KRFB Tender

Works
Civil And Construction
Road Construction
Eprocure
Opening Date2 Mar 2024
Closing DateCancelled
Tender Amount₹ 1,53,95,642 
Notes
Download

Costs

Summary

Smart Road Project At Id 108) Vjt Hall Flyover Road In Thiruvananthapuram Beautification Works

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)

42.67

-

-

... More
Brick work with common burnt clay F.P.S (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand)

47.52

-

-

... More
Pointing on brick work or brick flooring with cement mortar 1:3 ( 1 cement : 3 fine sand):Flush/ Ruled /Struck or weathered pointing

188.65

-

-

... More
Applying priming coats with primer of approved brand and manufacture, having low VOC ( Volatile Organic Compound) content.With water thinnable cement primer on walls surface having VOC content less than 50 grams / litre

168.55

-

-

... More
Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm

46.85

-

-

... More
Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work

137.96

-

-

... More
Mirror polishing on marble work/ granite work/stone work where ever required to give high gloss finish complete.

44.72

-

-

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m

101.84

-

-

... More
12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

52.14

-

-

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete

49.5

-

-

... More
Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete

4053.6

-

-

... More
Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete

1268

-

-

... More
Providing and fixing 15cm wide, 45 cm overall semi circular plain G.S. sheet gutter with iron brackets 40x3 mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.0.80 mm thick with zinc coating not less than 275 gm/m2

45.1

-

-

... More
Providing and fixing PVC pipes including fixing the pipe with clamps/ clip at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 6 Kgf/cm2 - External work - Exposed on wall

22.88

-

-

... More
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work

10.82

-

-

... More
Providing and fixing with 3mm thick Aluminum Composite Panel sheet having 0.25mm thick aluminum coating on both sides, to an existing framework fixed to the truss members for Ceiling and Cladding. The joints on the ACP sheet sealed with silicon sealant and aluminum beading, including all staging, scaffolding, supports, etc. complete., as per the drawing and as per the direction of Engineer in charge

14.3

-

-

... More
Plastering with cement mortar 1:4 ( 1 cement : 4 coarse sand) , 15 mm thick,including finishing with neat floating coat of red oxide etc... complete.

23.76

-

-

... More
Chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand):Medium shade pigment 50% white cement, 50 % ordinary cement

19.8

-

-

... More
PART A - CIVIL WORKS - ROAD ITEMS

-

-

-

... More
Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC Using Concrete Mixer on M-10 grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 409

39.6

-

-

... More
Dismantling of flexible pavements and disposal of dismantled materials up to a lead of 1000 metres, stacking serviceable and unserviceable materials separately<br> Bituminous course - By Mechanical Means<br>

26.84

-

-

... More
Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.

10.3

-

-

... More
Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications <br> RCC Grade M20 - Using Concrete Mixer - (Without formwork) <br>

4.15

-

-

... More
Supply, Fitting and Placing un- coated HYSD bar Reinforcement in Foundation complete as per Drawing and Technical Specifications

0.72

-

-

... More
Plain/Reinforced cement concrete in sub-structure complete as per drawing and Technical Specifications RCC Grade M20 - Using concrete Mixer - Height upto 5m

17.56

-

-

... More
Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, backfilling the excavation earth to the extent required and utilising the remaining earth locally for road work.<br> Ordinary soil - Mechanical Means - (Depth upto 3 m) <br>

33.55

-

-

... More
Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces

14.65

-

-

... More
Supplying and fixing 4 mm thick polycarbonate sheets of approved make and colour over the framework already erected, sheets fixed to the frame using special stainless steel extrusions, including all fasteners fixtures as per site requirement, applying silicone sealent wherever necessary so as to make the roof water tight at all heights as per manufacturer's Specifications and as directed by Engineer-in-Charge.

308.7

-

-

... More
PART A - CIVIL WORKS - LANDSCAPING(DSR)

-

-

-

... More
Supplying and stacking of good earth at site including royalty and carriage upto 5 k.m. lead complete (earth measured in stacks will be reduced by 20% for payment).

13.42

-

-

... More
Supplying and stacking sludge at site including royalty and carriage upto 5 k.m. lead complete (sludge measured in stacks will be reduced by 8% for payment).

10.07

-

-

... More
Supplying and stacking at site dump manure from approved source, including carriage upto 5 k.m. lead complete (manure measured in stacks will be reduced by 8% for payment) :Screened through sieve of I.S. designation 20 mm

6.71

-

-

... More
Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately).

30.2

-

-

... More
Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge

30.2

-

-

... More
Filling mixture of earth and sludge or manure in the desired proportion in trenches, flooding with water and leveling (cost of supplying earth and sludge or manure and mixing excluded).

30.2

-

-

... More
Providing & laying Selection no. 1 grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same, with sprinkler and maintenance for 30 days or more till the grass established properly as per direction of officer in charge

67.1

-

-

... More
Supply and stacking of Tabebuia sp. plant of height 150-165 cm. in big polybags of size 25 cm as per direction of the officer-in-charge.

80

-

-

... More
Supply and stacking of plant Tabernaemontana divaricata (Chandni double) of height 90-105cm, bushy in big size HDPE bag as per direction of the officer-in-charge.

100

-

-

... More
Supply and stacking of plant Portulaca hybrid

100

-

-

... More
Supply and stacking of plant Nerium oleander (kaner) of height 45-60 cm. with 3-4 branches in poly bags of size 20 cm as per direction of the officer-in-charge. Detail of cost each plant

50

-

-

... More
Supply and stacking of plant Bauhinia acuminata of height 60-75 cm. in earthen pots of size 20 cm as per direction of the officer-in-charge.

50

-

-

... More
Supply and stacking of Ficus benjamina (green) plant of height 150-165 cm, bushy with healthy branches and lush green foliage in big size HDPE bags as per direction of the officer-incharge.

50

-

-

... More
Supply and stacking of plant Jasminum Sambac species of height 45cm as per direction of the officer-in-charge

50

-

-

... More
Providing and displaying Ixora coccinia well developed with fresh and healthy bushy plant in full bloom 60cm height on already developed flowering bed as per the direction of Engineer in Charge.

50

-

-

... More
Providing and displaying Wadelia trilobata plant,full of leaves in 15 cm size of Polybags on already developed flowering bed as per the direction of Engineer in Charge

50

-

-

... More
PART B- WATER SUPPY ITEMS

-

-

-

... More
Supply of uPVC Pipe, IS 4985: 2000 , 6kg/cm2, 110mm Dia.

30

-

-

... More
Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials). 110 mm nominal outer dia pipes

30

-

-

... More
Supply of uPVC Pipe, IS 4985: 2000 , 8kg/cm2, 32mm Dia.

100

-

-

... More
Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials). 32 mm nominal outer dia pipes

100

-

-

... More
Supply and conveying 20 mm ASTM pipe

50

-

-

... More
Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials). 20 mm nominal outer dia pipes.

50

-

-

... More
Providing 15mm (1/2 inch) house connection with 15mm (1/2 inch) water meter from existing PVC / HDPE mains up to 110 mm dia., up to a length of 5m using 20mm Indian Standard Class 6 uPVC pipe and uPVC / GM / Brass specials viz. brass ferrule, GM full way wheel valve, Elbow, MTA, FTA, couplers, PVC Service Saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges but excluding cost of water meter and meter box and excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers.

4

-

-

... More
Additional Item for water connection charges to be paid to KWA, Amount will be reimbursed to the contractor as per the actual paid

-

-

-

... More
PART C - ELECTRICAL WORK- LIGHT FITTINGS

-

-

-

... More
Supply and fixing of IP 65 24W LED Lantern Ball String Light with pvc outer cover rates including all materials and labours charges

50

-

-

... More
Supply and fixing of IP 65 18W LED Lantern Ball String Light including all materials and labours charges

100

-

-

... More
Supply and fixing IP 65 single colour 12w/meter Led Flexible Rope Light. Rates Shall Include all materials and labours. Charges

1000

-

-

... More
Supply and fixing IP 65 12w/Meter Rice light ,as per the direction of Site-in-Charge. Rates including all materials and labours charges

2000

-

-

... More
Supply and fixing IP 65 60W/mtr floor light including all materials and labours charges

20

-

-

... More
Supply and fixing IP 65 100w LED inground focus Light Including all materials and labour charges

30

-

-

... More
Supply and fixing IP 65 30w LED spiked focus light Including all materials and labour charges

20

-

-

... More
Supply and fixing driver 12V DC power supply 400w-33A rain proof SMPS 240v AC to 12v DC converter.Rates including all labour and material charges etc.

100

-

-

... More
Supplying and fixing IP 65 10w LED inground focus light including all materials and labour charges

200

-

-

... More
Supply and fixing IP 65 60w IK 10 LED Pendant Lamp,as per the direction of Site-in Charge. Rates Including all materials and labour charges

10

-

-

... More
Supply and fixing IP 65 LED 20W/m strip Light,as per the direction of Site-in-Charge. Rates Including all materials and labour charges

250

-

-

... More
Supply and Installation of IP 65 rated 50W LED pole top focus light with 3m height pole made of mild steel/steel tube with IS 1161/IS 3601, minimum of not less than 2.5mm thickness. It shall have Mo sections. Bottom shall be minimum height of 1M with bottom dia of the shall be 114 m. The uppersection shall be not less than with minimum dia of 76 mm. The Pole is to be a suitable surface mounting base plate (steel of grade to IS 2062: 2011) and welded at the bottom ofthe with supporting gussets Pole shall be mounted on square base plate, suitable for mounting on 4 nos bolts. The Pole Shaf pipe should be fabricated out of Steel tube of grade YST 2101240. The pole shaft and base plate shall be hot dip galvanized (7 Stage process) as per IS 2629 before the coating of epoxy primer. Poles using pre galvanized steel tubes or hot dip galvanized through double dip process are not acceptable. Complete pole shall be treated with high quality epoxy zi rich penetrating primer 45 microns and thereafter coated with Polyurethane paint to minimum average DFT of Controlled paint drying process shall to ensure proper adhesion and finish of the paint. pole shall provide with Marine grade Painting. T shall conform to IS 12944 for CS Mx ist of 6A MCB with built in terminals for housing 3.5 core Sq MM armoured aluminium cable. The pole shall of ‘composite’ construction designed to specified ‘dead load’ pertaining to luminaire and its mounting ac@ssories and ‘wind load’ corresponding to a basic wind speed of 169kmph without any deformation or damage the structure. Should Include necessary foundation and foundation bolts.

10

-

-

... More
Supply and Installation of IP 65 rated 20W LED pathway pole top light with 3m height pole made of mild steel/steel tube with IS 1161/IS 3601, minimum of not less than 2.5mm thickness. It shall have Mo sections. Bottom shall be minimum height of 1M with bottom dia of the shall be 114 m. The uppersection shall be not less than with minimum dia of 76 mm. The Pole is to be a suitable surface mounting base plate (steel of grade to IS 2062: 2011) and welded at the bottom ofthe with supporting gussets Pole shall be mounted on square base plate, suitable for mounting on 4 nos bolts. The Pole Shaf pipe should be fabricated out of Steel tube of grade YST 2101240. The pole shaft and base plate shall be hot dip galvanized (7 Stage process) as per IS 2629 before the coating of epoxy primer. Poles using pre galvanized steel tubes or hot dip galvanized through double dip process are not acceptable. Complete pole shall be treated with high quality epoxy zi rich penetrating primer 45 microns and thereafter coated with Polyurethane paint to minimum average DFT of Controlled paint drying process shall to ensure proper adhesion and finish of the paint. pole shall provide with Marine grade Painting. T shall conform to IS 12944 for CS Mx ist of 6A MCB with built in terminals for housing 3.5 core Sq MM armoured aluminium cable. The pole shall of ‘composite’ construction designed to specified ‘dead load’ pertaining to luminaire and its mounting ac@ssories and ‘wind load’ corresponding to a basic wind speed of 169kmph without any deformation or damage the structure. Should Include necessary foundation and foundation bolts.

10

-

-

... More
Supply, installation, testing and commissioning of 9W ,12V, surface brightness 872cd/m^2, high polymer material, glass surface, LED interactive floor Light with colour RGB .LM 79 and LM 80 test certificate should be produced for LED Lighh

25

-

-

... More
PART C - ELECTRICAL WORK-CABLE LAYING

-

-

-

... More
Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm

598.25

-

-

... More
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 4 sq mm

500

-

-

... More
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3 core 4 sq mm

400

-

-

... More
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 10 sq mm

399.5

-

-

... More
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 16 sq mm

300

-

-

... More
Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 25 sq mm

200

-

-

... More
Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 35 sq mm

100

-

-

... More
Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 50 sq mm

250

-

-

... More
Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 185 sq mm

100

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm)

30

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X25 sq.mm (28mm)

10

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm)

20

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)

10

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)

10

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)

20

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)

20

-

-

... More
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate withinscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixingthe same in ground as required.

20

-

-

... More
Supplying and making outdoor end termination with cast resin compound including aluminiumlugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 185 sq. mm

4

-

-

... More
PART C - ELECTRICAL WORK-DISTRIBUTION BOARD AND PANELS

-

-

-

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door

4

-

-

... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4 + 12), Double door

4

-

-

... More
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (butwithout MCB's and incomer ) as required .(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)4 way (4 + 12), Double door

4

-

-

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

80

-

-

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole and netural

12

-

-

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole

4

-

-

... More
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps

4

-

-

... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

4

-

-

... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps

4

-

-

... More
Supply, Installation, Testing and Commissioning of SUB PANEL-2 IP55 OUTDOOR: (FABRICATED OUT OF 16G CRCA SHEET) BUS BAR : 25 X 6 X 1 ALUMINIUM FOR PHASE & 25 X 6 X 1 ALUMINIUM FOR NEUTRAL CABLE ENTRY : TOP / BOTTOM BASE : 75 X 40 X 40 C CHANNEL EARTHING : 25 X 3 X 1 mm CU BUS EARTHbrINCOMER: 1) 63A 4P 25KA THERMAL MAGNETIC BASED MCCB WITH 3OC, SC, ROM AND 2 SETS OF SPREADER WITH INTERPHASE BAREEIER 1 NOS METERING: 1) 2A SP MCB 6 NOS 2) LED INDICATION (R,Y,B) 1 SETS 3) VOLTMETER (0-500V) 1 NOS 4) VOLTMETER SELECTOR SWITCH 1 NOS 5) NEUTRAL LINK 1 NOSbrOUTGOING: 1) 63A TP MCB 1 NOS 2) 32A TP MCB 2 NOS 3) DIGITAL TIMER 2 NOS 4) 63A 4P POWER CONTACTOR 1 NOS 5) 32A 4P POWER CONTACTOR 1 NOS 6) ADDON BLOCK 2NO + 2NC 2 NOS 7)AUTO/MANUAL SELECTOR SWITCH 2 NOS 8) 25A DP MCB 1 NOS 9) 32A SP MCB 8 NOSbr

1

-

-

... More
Supply, Installation, Testing and Commissioning of SUB PANEL-1 IP55 OUTDOOR: (FABRICATED OUT OF 16G CRCA SHEET) BUS BAR : 25 X 6 X 1 ALUMINIUM FOR PHASE & 25 X 6 X 1 ALUMINIUM FOR NEUTRAL 2 NOS CABLE ENTRY : TOP / BOTTOM BASE : 75 X 40 X 40 C CHANNEL EARTHING : 25 X 3 X 1 mm CU BUS EARTHbrINCOMER: 1 100A 4P 25KA THERMAL MAGNETIC BASED MCCB WITH 3OC, SC, ROM AND 2 SETS OF SPREADER WITH INTERPHASE BAREEIER 1 NOSbrMETERING: 1) 2A SP MCB 6 NOS 2) LED INDICATION (R,Y,B) 1 SETS 3) VOLTMETER (0- 500V) 1 NOS 4)VOLTMETER SELECTOR SWITCH 1 NOS 5) NEUTRAL LINK 1 NOSbrOUTGOING: 1) 63A TP MCB 2 NO, 2) 32A TP MCB 2 NOS 3) DIGITAL TIMER 2 NOS 4) 63A 4P POWER CONTACTOR 1 NOS 5) 32A 4P POWER CONTACTOR 1 NOS 6) ADDON BLOCK 2NO + 2NC 2 NOS 7)AUTO/MANUAL SELECTOR SWITCH 2 NOS 8) 25A DP MCB 1 NOS 9) 32A SP MCB 8 NOSbr

1

-

-

... More
Supply, Installation, Testing and Commissioning of Main PANEL IP55 OUTDOOR: (FABRICATED OUT OF 16G CRCA SHEET) BUS BAR : 32 X 10 X 1 ALUMINIUM FOR PHASE & 32 X 6 X 1 ALUMINIUM FOR NEUTRAL, CABLE ENTRY : TOP / BOTTOM BASE : 75 X 40 X 40 C CHANNEL EARTHING : 25 X 3 X 1 mm CU BUS EARTHbrINCOMER: 1 250A 4P 36KA THERMAL MAGNETIC BASED MCCB WITH 3OC, SC, ROM AND 2 SETS OF SPREADER WITH INTERPHASE BAREEIER + NEUTRAL LINK 1 NOS, 250A FUSE BASE 3 NOS, 250A HRC FUSE 3 NOS, NEUTRAL LINK 1 NOS PROVISION FOR 3 PHASE ENERGY METER WITHOUT CT 1 NOS METERING: 1)2A SP MCB 6 NOS 2) LED INDICATION (R,Y,B) 1 SETS 3) VOLTMETER (0-500V) 1 NOS 4)VOLTMETER SELECTOR SWITCH 1 NOS 5) NEUTRAL LINK 1 NOSbrOUTGOING: 1) 100A 4P 25KA THERMAL MAGNETIC BASED MCCB WITH 3OC, SC, ROM AND 2 SETS OF SPREADER WITH INTERPHASE BAREEIER 2 NOS 2) 63A 4P 25KA THERMAL MAGNETIC BASED MCCB WITH 3OC, SC, ROM AND 2 SETS OF SPREADER WITH INTERPHASE BAREEIER 4 NOSbr

1

-

-

... More
Supply and Installation and Testing and Commissioning of Outdoor box with necessary accessories suitable for mounting 2/3 Module(Dimensions: 100 x 150 x 96 mm) MCBs with Transparent glass, with protection class IP65, 1 Row, 3 available modules, Rated operational voltage: 400V AC, Rated insulation voltage: 1000V AC, 1000V DC, metric knockouts on top and bottom for universal cable insertions with cable glands and/or double membrane seals, elastic entries double membrane seals M20 on top with PE/N terminal rail, each with 1 clamping point 16 mm² and 3 terminal points 6 mm² Accessories supplied: Double-membrane seals: 1x M25, sealing plugs, masking and labelling strips.brElectrical characteristics: Rated operating voltage AC: 400 V, Rated insulation voltage AC: 1000 V, Protection class: II ,Type of protection: IP65. brMaterial: Base unit material: Polycarbonate, Cover material: Polycarbonate, glass-fibre reinforced, Sealing material: Polyurethane, Cover screw material: Polyamide, glass-fibre reinforced, Hinged window material: Polycarbonate.brMaterial characteristics: UV-resistant: yes, Halogen free: yes, Flammability class according with UL94: V2, Glow-wire flammability according to EN 60695-2-11: 960 °C.brMechanical properties: Type of fastening: Surface mounting, Impact strength: IK08, Sealable: yes, Cover screw torque: 1.2 Nm.brMake : Spelsberg, Model no. AKi 03 or equivalent.

2

-

-

... More
Supply and Installation and Testing and Commissioning of Outdoor box with necessary accessories suitable for mounting 4 Module(Dimensions: 125 x 200 x 122 mm) MCBs with Transparent glass, with protection class IP65, 1 Row, 5 available modules, Rated operational voltage: 400V AC, Rated insulation voltage: 1000V AC, 1000V DC, metric knockouts on top and bottom for universal cable insertions with cable glands and/or double membrane seals, elastic entries double membrane seals M20 on top, with PE/N terminal rail, each with 2 terminal points 16 mm² and 3 terminal points 6 mm² Accessories supplied: Double-membrane seals: 1x M25, sealing plugs, masking and labelling strips.brElectrical characteristics:Rated operating voltage AC: 400 V, Rated insulation voltage AC: 1000 V, Protection class: II, Type of protection: IP65.brMaterial: Base unit material: Polycarbonate, Cover material: Polycarbonate, glass-fibre reinforced, Sealing material: Polyurethane, Cover screw material: Polyamide, glass-fibre reinforced, Hinged window material: Polycarbonate.brMaterial characteristics: UV-resistant: yes, Halogen free: yes, Flammability class according with UL94: V2, Glow-wire flammability according to EN 60695-2-11: 960 °C.brMechanical properties: Type of fastening: Surface mounting, Impact strength: IK08, Sealable: yes, Cover screw torque: 1.2 Nm.brMake : Spelsberg, Model no. AKi 05 or equivalent.br

2

-

-

... More
Supply and lnstallation 16A'3P lP67 lndustrial Plug & Sockets DB confirming to lS/lEC 30309 1 with 32A ELCB protection 2,lnsulated and made PC Conforming to RoHS – directive 20111651EU and contact pins :onformlng to RoHS-directive 2002/95/EG with 16A RCBO n a Transparent window; The Socket DB shall offer an Ingress Protection of lP65 ( Acc. to lS/lEC 60529) and lmpact Strength of lK08 ( Acc. to IEC 62262 ); The unit shall offer UV resistance with an operating Temperature ranges from -25°C to+85°C, The unit shall A/ithstand +100°C for 60 Min, Plug should have a Strain Relief cable glands shall be used in order to prevent risk of loose contacts in Plugs and sockets shall be tested and certified as per IEC 60309 from VDE / OVE aboratories Make: CAPE, Mennekes, Walther or equivalent.

20

-

-

... More
PART C - ELECTRICAL WORK-EARTHING

-

-

-

... More
Earthing with G.I. earth pipe 3 metre long, 40 mm dia including accessories, and providingbrmasonry enclosure with cover plate having locking arrangement and watering pipe etc. withbrcharcoal/ coke and salt as required

14

-

-

... More
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earthelectrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)

71

-

-

... More
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 3.15 mm copper conductor ( 10 SWG)

200.88

-

-

... More
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 4.00 mm copper conductor ( 8 SWG)

600

-

-

... More
Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)

40

-

-

... More
Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG)

60

-

-

... More
Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 6 mm GI strip

31

-

-

... More
PART C - ELECTRICAL WORK-SUPPLY AND LAYING DWC DUCT

-

-

-

... More
Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size

300

-

-

... More
Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation63/50 mm or nearest size

800

-

-

... More
Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation110/94 mm or nearest size

200

-

-

... More
Supplying, installation, testing and commissioning of Astronomical time switch KEL make or Equivalent including excavation, concrete works and structural steel work for frames etc complete as per the direction of Engineer in charge.

4

-

-

... More
PART C - ELECTRICAL WORK-P A SYSTEM

-

-

-

... More
Supply, installation , testing and commissioning of P A Sound Projector Speaker 24W RMS SPL-93dB, IP-44 degree of dust and water protection model SP-5251 T(Ahuja make / Equivalent)

1

-

-

... More
Supply, installation , testing and commissioning of P A Garden speaker 40 W RMS SPL-88db, water resistant polypropylene speakers. Strong Aluminium alloy housing permits various outdoor applications IP 55.Model GS-6401 T.(Ahuja make / Equivalent)

3

-

-

... More
Supply, installation , testing and commissioning of P A Amplifier 160 W RMS with Digital Player and Bluetooth, 5 mic 2 Aux Model SSA- 160 DP (Ahuja make / Equivalent)

1

-

-

... More
Supply and erection of Wall mount rack with glass door, lock and power switch Board 5 socket & switches 5A .6 U

1

-

-

... More
IT Components

-

-

-

... More
Supply, install and commissioning of 2 MP IR Speed Dome PTZ Outdoor IP 65 Camera including 5 year warrenty (Make in India)

1

-

-

... More
Supply, install and commissioning of 2 MP IR Bullet Outdoor IP Camera including 5 year warrenty (Make in India)

10

-

-

... More
Supply, install and commissioning of NVR: 16 Outdoor IP Cameras input including 5 year warrenty (Make in India)

1

-

-

... More
Supply, install and commissioning of Media Convertor with Two LAN Ports

1

-

-

... More
Supply, install and commissioning of SC/LC patch cord 1 mtr

2

-

-

... More
Supply, install and commissioning of 6 TB Hard Disk

1

-

-

... More
Supply and fix outdoor ( Armourd) CAT 6 Cable

300

-

-

... More
Supply and fix 4U Rack

1

-

-

... More
Supply and installation of Pole With mounting bracket for Camera

8

-

-

... More
Supply and lay PVC Pipe, 20mm dia

100

-

-

... More
Supply and install 1 KVA UPS with Battery - with 30 min backup (Make in India)

1

-

-

... More
Emergency Call Box with button, speaker and microphone, Voice recorder – 4 channel, Head phones

1

-

-

... More
Supply, Install and commissioning Wi-Fi Hotspot Device

2

-

-

... More
Supply, installation and commisioning MS Pole with Water Proof Cabinet, With Lock & Key for keeping UPS, NVR, Media converter etc.

1

-

-

... More
Supply, installation and commisioning Interactive Information KIOSK

1

-

-

... More
Supply, installation and commisioning IP Audio System with POE speakers (Minimum 2 numbers) as specified.

1

-

-

... More
Operation and Mainanence

-

-

-

... More
Maintanance charges of Landscaping per month for First Year

12

-

-

... More
Maintanance charges of Landscaping per month for Second Year

12

-

-

... More
Maintanance charges of Landscaping per month for Third Year

12

-

-

... More
Maintanance charges of Landscaping per month for Fourth Year

12

-

-

... More
Maintanance charges of Landscaping per month for Fifth Year

12

-

-

... More
Maintanance charges of road works and other components except landscaping per month for Fourth Year

12

-

-

... More
Maintanance charges of road works and other components except landscaping per month for Fifth Year

12

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.