Kerala Police Housing And Construction Corporation Limited Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 50,000Document Cost
₹ 2,950Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_KPHCC_678622_2Tender No
NIT No.34/KPHCC/2024-25Tender Authority
Kerala Police Housing And Construction Corporation Limited ViewPurchaser Address
-Website
http://https://kphccltd.kerala.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
2.33.2: Felling trees of the girth (measured at a height of 1 m above ground level) including
cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyound 60 cm girth up to and including 120 cm girth
16
-
-
50.2.33.6: Cutting branches of trees overhanging above any structures of girth between 60cm to
90cm including stacking of serviceable materials and disposal of unserviceable material, cost of labour, hire charges of rope and pully etc without making any damages to nearby structures etc complete
60
-
-
50.2.33.8: Cutting branches of trees overhanging above any structures of girth beyond 120cm
including stacking of serviceable materials and disposal of unserviceable material, cost of labour, hire charges of rope and pully etc without making any damages to nearby structures etc complete.
32
-
-
OD1766/2024-2025: Labour Engaged for coolie
40
-
-
OD1767/2024-2025: Wood cutter per day
16
-
-
OD1768/2024-2025: DOWEL BARS - Supplying and providing MS dowel bars of size 16 mm dia of 0.60 m long (30 cm in rock and 30cm in concrete ) including drilling holes of 20mm dia to a depth of 0.30m in rock and filling the gap with cement grout( 0.075kg/each) etc complete.
200
-
-
4.1.3: Providing and laying in position cement concrete of specified grade excluding the
cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
20.25
-
-
4.3.1: Centering and shuttering including strutting, propping etc. and removal of form work
for:Foundations, footings, bases for columns
90
-
-
50.10.1: Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
7741.68
-
-
10.25.2: Item Shifted to Sub head 14 as item 14.73
Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using
structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
169.5
-
-
13.52.1: Finishing with Epoxy paint (two or more coats) at all locations prepared and applied
as per manufacturer's specifications including appropriate priming coat, preparation
of surface, etc. complete.On steel work
367.04
-
-
OD1769/2024-2025: Supplying and fixing bittom fixture bush(adopter for 75mm pipe into 50mmpipe
acting as a insulator to energizethe raiser pipe,the bush must be made of virgin PP or equivalent material and UV Stabilised)including all cost and conveyance etc complete
375
-
-
OD1770/2024-2025: providing and fixing reel insulator made up of virgin durable quality, sturdiness, unit weight 18g or nearest, withstanding voltage 15kV 15 kV
136
-
-
OD1771/2024-2025: Supplying and fixing permanent wire Tightner corrosion resistant pressure diecasting process, using LM6 grade aluminum alloy. it is used to tighten fence wire and maintain adequate tension. etc. complete as per the direction of engineer in charge
1005
-
-
OD1772/2024-2025: Supply and fixing of Super Strain insulator (Poly propylene, <br>400 N, 15 KV Guy type )
44
-
-
OD1773/2024-2025: providing warning signs poly-rthlene plastic with statutory colour and signs
144
-
-
OD1774/2024-2025: providing and fixing of bullets(connectors)-copper material or aluminium or stainless steel material having an inner
core hole size of 2.5mm dia ,2cm length including all cost
10000
-
-
OD1775/2024-2025: Providing and laying of fence wire SWG 12 ACSR high tension hot dipped, size 2.59 mm, standard IS 398-part2 /1996, breakage capacity 600kg, purity of zinc 99.95% w of coating 230g/m2, GI systematic make etc. complete as per direction of engineer in charge.(Quality of ACSR wire should be assured with test result and certificates)
12000
-
-
OD1776/2024-2025: Providing and fixing 3.2 Mtr spiral model GI fence wire 14 SWG (hanging type)
Approved make etc. complete. as per direction of engineer in charge.(Quality of GI fence wire should be assured with test result and certificates)
10000
-
-
ELECTRICAL WORK
-
-
-
1.10.1 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC
conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5
sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group A
2
-
-
1.21.1: Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
30
-
-
5.4: Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as
required
2
-
-
OD1777/2024-2025: providing and fixing of lightning diverter must be capable of diverting stray
lightening. The diverter assembly must be adjustable for spark gaps. : Adequate earthing to be provided
2
-
-
OD1778/2024-2025: Supply and fixing of Solar Charge Controller with display 12v/24v to regulate the charging of the battery of approved brand
2
-
-
OD1779/2024-2025: Fabrication Supply and installation of Module Stand and water proof Battery and equipment safety box with following specifications 50mm dia 2.75mtr long gi base pipe and connect L angle through pipe for fixing 2nos solar panels and providing dust,water and vermin proof floor mounting cubicle type rack fabricated from 1.6mm/16swg CRCA sheet,and powder coated ,hinged door,rubber beedings and provision for energizer,charge controller and 2 nos of battery etc as required.
2
-
-
OD1780/2024-2025: Supply and Installation of 12 volt 150AH Solar VRLA , SMF battery with connecting wires etc as required Exide/amron/Hykon or equivalent
4
-
-
OD1781/2024-2025: providing and fixing 160 watts, mono crystalline solar panel 12 volts rating with
minimum 10 years performance warranty against manufacturing defects. Make waree, adani or equivalent
4
-
-
OD1782/2024-2025: providing and fixing GSM alert system with fence voltage alarm and sms alert to
mobile number
2
-
-
OD1783/2024-2025: Supply and installation of Energizer with following specification; 12 V Energizer of Make:JVA dual zone with adaptor or equivalent ,must confirm to IEC standard 60335.2.76 or IS 302-3-76 (1999) and all national and international standards of safety ,switch to high and low power setting , solar panel option to recharge 12volt battery ,Should possess the following output characters , Peak o/p voltage not more than 10kv on 50Kload , o/o energy 3.5 J minimum pulse duration 1.01-3.0m sec- ,Pulse interval 1.1- 1.4 sec , peak current 7.0-8.0 A .
2
-
-
OD1784/2024-2025: Providing Digital volt meter must display fence voltage in kilowatt up to 9.9kv
including all cost
2
-
-
OD1785/2024-2025: supply of Tool Kit cutting pliers, crimping tool, multi meter, double ended spanner etc as required
2
-
-
OD1786/2024-2025: supply and drawing DC Solar cable 4 sq mm single run with UV protection of reputed brand connection etc as required
20
-
-
OD1787/2024-2025: Providing and laying of Lead Out Cable must be double insulated withstanding
15KV voltage and inner core wire must be GI
30
-
-
OD1788/2024-2025: supply and installing multi spike Lightning arrester Must be capable of diverting stray lightning in suitable height including GI pipe for fixing and concrete/equivalent for fixing on the ground
2
-
-
OD1789/2024-2025: Earthing system Must contain earth mixture capable of retaining moisture and 8 mm dia stainless steel rod grade 304 or above non rusting quality of 4 feet long
27
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements