Kerala Police Housing And Construction Corporation Limited Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Kerala Police Housing And Construction Corporation Limited - KPHCCL Tender
Civil And Construction
Building Construction
Eprocure
Opening Date2 Sep 2024
Closing Date9 Sep 2024
Tender Amount₹ 2,15,693
Costs
EMD
₹ 5,400Document Cost
₹ 590Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_KPHCC_688764_1Tender No
NIT No. 78/KPHCC/2024-25Tender Authority
Kerala Police Housing And Construction Corporation Limited ViewPurchaser Address
-Website
http://https://kphccltd.kerala.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
50.18.9.18.2
Providing and fixing PVC pipes including fixing the pipe with clamps/Clips at 1.00 m
spacing. This included jointing of pipes with one step PVC solvent cement and testing
of joints complete as per direction of Engineer-in-Charge 75 mm dia 4 Kfg/cm2 -
External work - Exposed on wall
5
-
-
OD12736/2024-2025
Providing and fixing manual Controlled Zebra Curtains/Blinds made of premium
quality fabric around aluminium tube to be raised and lowered by ball chain pulley, to
provide adequate privacy and light control (Make : SERA ZG/equivalent, model:
EASTHER MAGIC SHADE - EM –6/2 - SAND). as per architect approved
shade .Including cost and conveyance of all materials labour charges etc.
4.1
-
-
OD12738/2024-2025
Supplying and providing executive revolving chair
2
-
-
OD13565/2024-2025
Supplying and providing single seat work station 110 x 60 x 75 cm using 16 mm (or
nearest ) thick treated rub wood well planed finished with suitable grains and polished
in mechanized plants wood panels for top. The verticals, horizontals and two facing
sides are using 15mm panels. providing 1 Nos of drawers and one number key board
using 15mm panels. hinges, (ebco or equivalent) best quality alloy sliders, S S
handles, locks and keys, one number of cabinet with shutter, one number of open
CPU cabinet etc complete, (sub: minor variations in site condition) design or direction of engineer in charge.
2
-
-
Electrification work
-
-
-
1.17.12
Supplying and drawing following sizes of FRLS PVC insulated copper conductor,
single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x
2.5 sq. mm
50
-
-
1.17.1
Supplying and drawing following sizes of FRLS PVC insulated copper conductor,
single core cable in the existing surface / recessed steel/ PVC conduit as required.1 x
1.5 sq. mm
60
-
-
1.21.1
Supplying and fixing of following sizes of medium class PVC conduit along with
accessories in surface/ recess including cutting the wall and making good the same in
case of recessed conduit as required.20 mm
Net Total 20.000metre
20
-
-
90.10.1.5
Supply & Fixing the following types/ sizes of boxes suitable for modular
accessories in surface/ recess including making good the damages, colour washing etc
as required (RoHS compliant )6 module moulded plastic box on surface
3
-
-
1.24.1
Supplying and fixing following modular switch/ socket on the existing modular plate
& switch box including connections but excluding modular plate etc. as
required.5/6 amps switch
6
-
-
1.24.4
Supplying and fixing following modular switch/ socket on the existing modular plate
& switch box including connections but excluding modular plate etc. as
required.3 pin 5/6 amp socket outlet
6
-
-
1.7.10
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of
FRLS PVC
insulated copper conductor, single core cable in surface/ recessed steel conduit as
required4 X 10 sq. mm + 2 X 6 sq. mm earth wire
12
-
-
1.24.3 Supplying and fixing following modular switch/ socket on the existing modular plate
& switch box including connections but excluding modular plate etc. as
required.15/16 amp switch
1
-
-
90.10.1.3
Supply & Fixing the following types/ sizes of boxes suitable for modular
accessories in surface/ recess including making good the damages, colour washing etc
as required (RoHS compliant )3 module moulded plastic box on surface
1
-
-
1.24.5
Supplying and fixing following modular switch/ socket on the existing modular plate
& switch box including connections but excluding modular plate etc. as
required.6 pin 15/16 amp socket outlet
1
-
-
90.11.1.11
Supply and installation of sheet steel, phosphatised and painted, dust and vermin
proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus
and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable
anchor bolts or fixed in recess including cutting hole on the wall , making good the
damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP
42/43)
1
-
-
2.3.3
Supplying and fixing following way, single pole and neutral, sheet steel, MCB
distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar,
neutral bus bar, earth bar, din bar, interconnections, powder painted including
earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
1
-
-
2.12.1
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing
MCB DB complete with connections, testing and commissioning etc. as required.40
amps
1
-
-
2.14.2
Supplying and fixing following rating, double pole, (single phase and neutral), 240
volts, residual
current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in
the existing MCB DB complete with connections, testing and commissioning etc. as
required.40 amps
1
-
-
90.11.1.14
Supply and installation of sheet steel, phosphatised and painted, dust and vermin
proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable
anchor bolts or fixed in recess including cutting hole on the wall , making good the
damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical
DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/
TP MCB as outgoing (IP 42/43)
1
-
-
2.10.1
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve,
miniature circuit breaker suitable for inductive load of following poles in the existing
MCB DB complete with connections, testing and commissioning etc. as
required.Single pole
27
-
-
2.10.4
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve,
miniature circuit breaker suitable for inductive load of following poles in the existing
MCB DB complete with connections, testing and commissioning etc. as
required.Triple pole
2
-
-
2.15.3
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts,
residual
current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in
the existing MCB DB complete with connections, testing and commissioning etc. as
required.63 amps
1
-
-
2.13.2
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing
MCB DB complete with connections, testing and commissioning etc. as required.63
amps
2
-
-
90.12.7.42
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured
aluminium power cable, 1.1 KV grade of the following sizes using clamps noted
along with the cables, spacing of clamps not exceeding 60cms, making good the
damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp
10
-
-
9.1.34
Supplying and making end termination with brass compression gland and aluminium
lugs for
following size of PVC insulated and PVC sheathed / XLPE aluminium conductor
cable of 1.1 KV
grade as required.4 X 25 sq. mm (28mm)
2
-
-
OD13846/2024-2025 Fabrication, supply & installation of dust and vermin proof, wall mounting, three
phase Meter Box of suitable for fixing KSEB meter,fuse units, CT etc, hinged door
construction for the front side with compartments if necessary, providing vision panel
for the meter compartment, knock out for cable entry and exit with the following.
63A,415V Fuse- 3 Nos, 63A ,415V ,Neutral Link- 1 No,63A TPN SFU- 1No, 63A
HRC Link - 1 No
1
-
-
90.16.1.3
Supply and drawing bare earthing conductors of the following sizes along with
wiring/ cables and giving connection as required3.15 mm copper conductor ( 10
SWG)
50
-
-
90.16.5.3
Supply of superior quality copper earth socket for the following size of earth
conductor including crimping etc. as required.3.15 mm (10 SWG)
8
-
-
5.4
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including
accessories, and providing masonry enclosure with cover plate having locking
arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as
required.
2
-
-
1.10.1
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm
FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC
conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5
sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group A
6
-
-
1.25
Supplying and fixing two module stepped type electronic fan regulator on the existing
modular plate switch box including connections but excluding modular plate etc. as
required.
3
-
-
90.4.5.4
Supply, Installation, testing and commissioning of ceiling fan of following sizes
including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm
FRLS PVC insulated, copper conductor, single core cable etc. as required.
1200mm sweep - ceiling fan complete with service value minimum 4.0(cub
meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding
suitable for 230V/240V single phase AC supply
3
-
-
OD13861/2024-2025
Supply and providing 20W LED Tube of department approved make as instructed by
engineer in charge.
amps
6
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements