Kerala Police Housing And Construction Corporation Limited Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Kerala Police Housing And Construction Corporation Limited - KPHCCL Tender
Civil And Construction
Eprocure
Opening Date17 Oct 2024
Closing Date25 Oct 2024
Tender Amount₹ 38,18,376
Costs
EMD
₹ 50,000Document Cost
₹ 2,950Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_KPHCC_695312_1Bid Award Id
ViewTender No
NIT NO. 110/KPHCC/2024-25Tender Authority
Kerala Police Housing And Construction Corporation Limited ViewPurchaser Address
-Website
http://https://kphccltd.kerala.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
OD34955/2023-2024
Providing and laying Vitrified step tiles in single piece indifferent sizes (thickness to
be specified by
manufacturer),using High polymer modified quickset tile adhesive with water
absorption less than 0.08 % and conforming to I.S. 15622, of approved make,
in all colours & shade, in skirting, riser of steps,
including grouting the joint with white cement & matching pigments etc.
complete
21.6
-
-
FALSE CEILING-12.45.1
Providing and fixing false ceiling at all height including providing and fixing of frame
work made of special sections, power pressed from M.S. sheets and galvanized with
zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of
angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at
1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm
dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers
of 25x10x0.50 mm of required length with nuts & bolts of required size and other end
of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the
spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick
bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm,
at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I.
-
-
-
intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long
G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm
high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to
wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall
screws @ 230 mm interval, including fixing of gypsum board to ceiling section and
perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c,
including jointing and finishing to a flush finish of tapered and square edges of the
board with recommended jointing compound, jointing tapes, finishing with jointing
compound in 3 layers covering upto 150 mm on both sides of joint and two coats of
primer suitable for board, all as per manufacturer's specification and also including
the cost of making openings for light fittings, grills, diffusers, cutouts made with
frame of perimeter channels suitably fixed, all complete as per drawings, specification
and direction of the Engineer in Charge but excluding the cost of painting with:12.5
mm thick tapered edge gypsum plain board conforming to IS : 2095-Part 1
176.94
-
-
Glass Door , Partition and Horizontal blinds
-
-
-
OD34908/2023-2024
Toughened Glass Door :
Providing and fixing Single door (110 x210 cm) of 12mm thick Toughened glass door
(Saint Gobain or Equivalent) with (dormakaba or Equivalent) patch fittings (Floor
Spring, Top patch, pivot Pin, Bottom patch, Corner lock, Handle- Dorma TGDIH 25
x 350 mm Stainless Steel 304 H-Type Glass Door Handle - Satin Finish ). Including
all cost and conveyance of materials, labour etc. complete.
6
-
-
OD34909/2023-2024
Providing and fixing 12mm thick Toughened glass(Saint Gobain) Partition System
with powder Coated aluminium Sections(Fish mouth channel /40 mm wide)Clip
sytem as per drawing /instruction of Engineer in charge .Including all cost and
conveyance of materials, labour etc complete.
8.11
-
-
OD34910/2023-2024
Supplying and Fixing Etching sticker for glasses in doors and fixed partition
including all cost and labour charges etc complete.
10
-
-
21.1.1.2
Providing and fixing aluminium work for doors, windows, ventilators and partitions
with extruded built up standard tubular sections/ appropriate Z sections and other
sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash
fasteners of required dia and size, including necessary filling up the gaps at junctions,
i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc.
Aluminium sections shall be smooth, rust free, straight, mitred and jointed
mechanically wherever required including cleat angle, Aluminnium snap beading for
glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural
drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):
For fixed portionPowder coated aluminium (minimum thickness of powder coating
50 micron)
76.5
-
-
21.2.2
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer
or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling
fixed in aluminum doors, windows shutters and partition frames with C.P. brass /
stainless steel screws etc. complete as per architectural drawings and directions of
Engineer - in- Charge.Pre- laminated particle board with decorative lamination on
both sides
11.4
-
-
OD34958/2023-2024
Providing and fixing manual Controlled Zebra Curtains/Blinds made of premium
quality fabric around aluminium tube to be raised and lowered by ball chain pulley, to
provide adequate privacy and light control (Make : SERA ZG/equivalent, model:
EASTHER MAGIC SHADE - EM –6/2 - SAND). as per architect approved
shade .Including cost and conveyance of all materials labour charges etc.
23.4
-
-
Work Station
-
-
-
OD34680/2023-2024
Supplying and providing single seat work station 110 x 60 x 75 cm using 16 mm (or
nearest ) thick treated rub wood well planed finished with suitable grains and polished
in mechanized plants wood panels for top. The verticals, horizontals and two facing
sides are using 15mm panels. providing 1 Nos of drawers and one number key board
using 15mm panels. hinges, (ebco or equivalent) best quality alloy sliders, S S
handles, locks and keys, one number of cabinet with shutter, one number of open
CPU cabinet etc complete, (sub: minor variations in site condition) design or direction
of engineer in charge.
44
-
-
OD34713/2023-2024
Supplying and placing Chair (make Minister ,Model :shell Task/Equivalent) as per
design intent .including all cost and conveyance of materials labour etc complete
46
-
-
Sheet roofing
-
-
-
OD34959/2023-2024
Roofing with Pre Laminated Shingles of overall 6mm thick fixed with adhesive on
12mm thick V board. V Board 10mm thick cement based board above the already
fabricated and erected rafters and purlins using MS rectangular/Square tubular
sections of suitable sizes as per approved design and drawing including cost and
conveyance of all materials hire and labour charges, Cost of scaffolding etc.,
complete.
21
-
-
10.16.1
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses
etc., including cutting, hoisting, fixing position and applying a priming coat of
approved steel primer, including welding and bolted with special shaped washers etc.
complete.Hot finished welded type tubes
70
-
-
Finishing works
-
-
-
13.48.1
Finishing with Deluxe Multi surface paint system for interiors and exteriors using
primer as per manufacturers specifications:Two or more coats applied on walls @
1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10
sqm
420
-
-
13.7.1
12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1
cement : 3 fine sand)
5.98
-
-
Electrification
-
-
-
1.10.2
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm
FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC
conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5
sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group B
50
-
-
1.10.3
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm
FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC
conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5
sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group C
20
-
-
1.14.9
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of
FRLS PVC insulated copper conductor, single core cable in surface / recessed
medium class PVC conduit as required4 X 6 sq. mm + 2 X 6 sq. mm earth wire
80
-
-
1.14.10
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of
FRLS PVC insulated copper conductor, single core cable in surface / recessed
medium class PVC conduit as required4 X 10 sq. mmd.
20
-
-
1.17.3
Supplying and drawing following sizes of FRLS PVC insulated copper conductor,
single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X
1.5 sq.mm
500
-
-
1.17.12
Supplying and drawing following sizes of FRLS PVC insulated copper conductor,
single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x
2.5 sq. mm
800
-
-
1.17.21
Supplying and drawing following sizes of FRLS PVC insulated copper conductor,
single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x4 sq. mm
250
-
-
1.21.1
Supplying and fixing of following sizes of medium class PVC conduit along with
accessories in surface/ recess including cutting the wall and making good the same in
case of recessed conduit as required.20 mm
900
-
-
1.21.2
Supplying and fixing of following sizes of medium class PVC conduit along with
accessories in surface/ recess including cutting the wall and making good the same in
case of recessed conduit as required.25 mm
500
-
-
1.24.1
Supplying and fixing following modular switch/ socket on the existing modular plate
& switch box including connections but excluding modular plate etc. as required.5/6 amps switch
100
-
-
1.24.4
Supplying and fixing following modular switch/ socket on the existing modular plate
& switch box including connections but excluding modular plate etc. as required.3
pin 5/6 amp socket outlet
100
-
-
1.24.3
Supplying and fixing following modular switch/ socket on the existing modular plate
& switch box including connections but excluding modular plate etc. as
required.15/16 amp switch
8
-
-
1.24.5
Supplying and fixing following modular switch/ socket on the existing modular plate
& switch box including connections but excluding modular plate etc. as required.6
pin 15/16 amp socket outlet
8
-
-
1.25
Supplying and fixing two module stepped type electronic fan regulator on the existing
modular plate switch box including connections but excluding modular plate etc. as required.
15
-
-
1.27.2
Supplying and fixing following size/ modules, GI box alongwith modular base &
cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
6
-
-
1.31
Supplying and fixing suitable size GI box with modular plate and cover in front on
surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket
outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be
used in non residential buildings).
5
-
-
1.43
Providing and fixing extra conduit down rod of 20 mm dia, 2X10 cm length wiring
with 2 X1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable
including painting etc. as required. (Note: More than 5 cm length shall be rounded to
the nearest 10 cm and 5 cm or less shall be ignored)
15
-
-
1.55.1
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell
point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper
conductor single core cable in surface/ recessed PVC conduit, and earthing the point
with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as
required.Group A
20
-
-
1.55.2
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell
point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper
conductor single core cable in surface/ recessed PVC conduit, and earthing the point
with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group B
20
-
-
1.56
Supplying and fixing suitable size Gl box with modular plate and cover in front on
surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket
outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light
plugs to be used in non residential buildings).
5
-
-
2.10.1
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature
circuit breaker suitable for inductive load of following poles in the existing MCB DB
complete with connections, testing and commissioning etc. as required.Single pole
36
-
-
2.13.1
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing
MCB DB complete with connections, testing and commissioning etc. as required.40
amps
6
-
-
2.15.2
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts,
residual
current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in
the existing MCB DB complete with connections, testing and commissioning etc. as
required.40 amps
2
-
-
2.10.4
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature
circuit breaker suitable for inductive load of following poles in the existing MCB DB
complete with connections, testing and commissioning etc. as required.Triple pole
2
-
-
90.11.1.11
Supply and installation of sheet steel, phosphatised and painted, dust and vermin
proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus
and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable
anchor bolts or fixed in recess including cutting hole on the wall , making good the
damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP
42/43).
2
-
-
90.3.12
Conveyance and fixing charges of recess mounting down light fittings of all types
complete with all accessories in the existing opening of false ceiling, giving
connections with the existing wire etc., as required.
105
-
-
90.4.1
Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per
IS 732 as required.
15
-
-
90.4.5.4
Supply, Installation, testing and commissioning of ceiling fan of following sizes
including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm
FRLS PVC insulated, copper conductor, single core cable etc. as required.
1200mm sweep - ceiling fan complete with service value minimum 4.0(cub
meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding
suitable for 230V/240V single phase AC supply
15
-
-
90.10.1.3
Supply & Fixing the following types/ sizes of boxes suitable for modular accessories
in surface/ recess including making good the damages, colour washing etc as required
(RoHS compliant )3 module moulded plastic box on surface
8
-
-
90.10.1.5
Supply & Fixing the following types/ sizes of boxes suitable for modular accessories
in surface/ recess including making good the damages, colour washing etc as required
(RoHS compliant )6 module moulded plastic box on surface
50
-
-
90.10.3.15
Supply and Fixing the following modular switches & accessories in the existing front
plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator
8
-
-
90.10.3.33
Supply and Fixing the following modular switches & accessories in the existing front
plates and giving necessary connections as required (RoHS compliant )25A 3pin
Shuttered socket
8
-
-
OD34226/2023-2024
Supply and providing 9W recess mounted ceiling light of department approved make
as instructed by engineer in charge.
60
-
-
OD34227/2023-2024
Supply and Providing 6W LED Strip, giving connection etc complete as required.
60
-
-
OD34228/2023-2024
Supply and providing 3Amps Led driver for the 6W LED Strip.
12
-
-
OD34229/2023-2024
Supply and providing 18W recess mounted ceiling light of department approved
make as instructed by engineer in charge.
5
-
-
OD34230/2023-2024
Supply and providing 15W LED panel light having CRI &80 , colour temperature
-4000K with IP 20 rating of approved make as instructed by department engineer in
charge.
40
-
-
OD34231/2023-2024
Supply and providing 20W LED Tube of approved make with lumens efficiency of
100 lumens /watt, THD<=20, CRI>80,Colour temperature of 3000K with
inbuilt surge protection(2.5KV).
4
-
-
Networking
-
-
-
OD34233/2023-2024
Supply and providing Cat 6 Input/Output Modular socket with plate on surface
50
-
-
OD34240/2023-2024
Supply,crimping RJ45 connectors /sockets and fixing to the existing enclosure and
giving connection etc
complete.
50
-
-
OD34234/2023-2024
Supply and providing 2 Mtr Patch Cord
50
-
-
OD34235/2023-2024
Supply and providing 1Mtr Patch Cord.
50
-
-
OD34860/2023-2024
Supply and installation of Layer 2 managable PoE switch with Non blocking switch
fabric having 24 Port 10/100/1000Mbps PoE & 4x1G SFP port. Three year
warranty.
1
-
-
OD34861/2023-2024
Supply,installation,testing and commissioning of 24 Port Gigabit Switch(10/100/1000 mbps) of govt approved make, giving connection etc. complete as
required
4
-
-
OD34858/2023-2024
Supply ,providing and fixing of 6U cabinet of approved make powder coated with
glass panel front door including PDU, cable management system and giving
connection etc complete as required.
2
-
-
OD34859/2023-2024
Supply and installation of Cat6 UTP , Patch Panel - 24 ports fully loaded patch panel
with rear strain release bar.
4
-
-
1.53.1
Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing
surface/recessed steel/PVC conduit as required1 run of Cable
1200
-
-
Air Conditioners
-
-
-
OD34241/2023-2024
Supply,installation,testing and commissioning of 2 Ton Spilt Type Air Conditioner
with 5 KVA stabilizer of department approved make as instructed by engineer in
charge, giving connection etc. complete as required.
1
-
-
OD34241/2023-2024
Supply,installation,testing and commissioning of 2 Ton Spilt Type Air Conditioner
with 5 KVA stabilizer of department approved make as instructed by engineer in
charge, giving connection etc. complete as required.
7
-
-
OD34246/2023-2024
Outdoor support for air conditioners
8
-
-
OD34247/2023-2024
Extra Copper pipping for the spilt type air conditioners
80
-
-
UPS
-
-
-
OD34242/2023-2024
Supply and Installation and onsite warranty of BIS
Certified 5KVA/120 VDC True Online IGBT Basedmicroprocessor controlled double conversion
technology Online UPS with Inbuilt Isolation
Transformer, with static bypass with zero break time,
Communication Interface and with 10 Nos. of
12V/40AH Tubular Batteries with Battery Rack and
accessories. Mandatory CERTIFICATION FOR UPS - ISO9001-2015,ISO14001 -2015, ISO 45001:2018(OHSAS), CE Certification AND BIS Certification, RoHS Compliant,IEC 62040 – 1, 2 & 3. OEM Should have production unit
and minimum 6 registered service centers in Kerala.
2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements