Kerala Police Housing And Construction Corporation Limited Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 7,900Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2018_KPHCC_214066_1Bid Award Id
ViewTender No
NIT 05/PS/18-19(50)Tender Authority
Kerala Police Housing And Construction Corporation Limited ViewPurchaser Address
-Website
http://https://kphccltd.kerala.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Preliminary agreement with stamp paper worth of Rs.200/-
BOQ Items
Laterite neatly dressed stones of size 32x22x20 cm in cement mortar 1:6 for foundation and basement including all charges, cost and conveyance of all matrials and labour charges etc. complete. (25Km conveyance)
7.5
39468
5262.5
Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,
consolidating each deposited layer by ramming and watering, lead up
to 50 m and lift upto 1.5 m.
4.9
863
176.3
Laterite masonry in cement mortar 1:6 (1 cement and 6 coarse sand) using good quality laterite stones neatly dressed of size 35 x 20 x 14 cm for superstructure including all scaffolding charges, cost and conveyance of all matrials and labour charges etc. complete.
8
46003
5750.39
Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete. Lintels, beams, plinth beams, girders, bressumers and
cantilevers
5.2
2499
480.74
Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access
platform. with water proof ply 12 mm thick
28
16577
592.06
Reinforced cement concrete work in beams, suspended floors, roofs
having slope up to 15° landings, balconies, shelves, chajjas, lintels,
bands, plain window sills, staircases and spiral stair cases above plinth
level up to floor five level, excluding the cost of centering, shuttering,
finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand
(zone-III) : 3 graded stone aggregate 20 mm nominal size).
3.1
32121
10361.9
Steel reinforcement for R.C.C. work including straightening, cutting,
bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500 D or more.
243
19282
79.35
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). (Flooring)
0.81
5085
6278.36
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08%and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
14.3
22442
1569.39
Roof top plastering, Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 12 mm cement plaster
19.7
6482
329.04
Ceiling plastering 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand)including watering, curing, cost and conveyance of all materials and labour charges etc. complete.
37.4
7539
201.6
Plastering 12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand).
86.2
20900
242.47
White washing with lime to give an even shade. New work (three or more coats). to the ceiling and the inside walls above lintel level including cost and conveyance of all materials and labour charges etc. complete
12
290
24.18
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm).
74
10042
135.71
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade. New work (two or more coats) over and including water thinnable priming coat with cement primer to the newly plastered inner walls below lintel level after cleaning the surface and smoothening with sand paper including cost and conveyance of all materials and labour charges etc. complete
38
4991
131.36
Making plinth protection 50 mm thick concrete 1:3:6 ( 1cement:: 3 coarse sand: 6 graded stone aggregate 20mm nominal size) over 75 mm thick bed of dry brick ballast 40mm nominal size, well rammed and consolidated and grouted with fine sand, including watering, curing, cost and conveyance of all materials and labour charges etc complete.
3.2
2020
631.39
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.
99
15607
157.65
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately).Powder coated aluminium (minimum thickness of powder coating 50 micron).
20.5
11050
539.06
Providing and fixing aluminium work for shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). Powder coated aluminium (minimum thickness of powder coating 50 micron).
21.7
13535
623.74
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness
5.5
5717
1039.58
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side
1
1158
1158.54
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ), transparent or dyed to required colour or shade, with necessary screws etc. complete. 200 x 10 mm.
2
213
106.76
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete. 125mm
2
143
71.64
Providing and fixing ISI marked 200 mm Aluminium Aldrop with 12mm rod with necessary screws etc. complete.
1
182
182.99
ELECTRICAL WORKS
-
-
-
Wiring for light point/ exhaust fan point/ call bell point with1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
-
-
-
Group A ( Short Point)
1
768
768
Group B (Medium point)
2
1724
862
Supply wiring light point as detailed above but without ceiling rose for batten point with angle/steady batten holder.
-
-
-
Group A ( Short Point)
1
873
873
Group B (Medium point)
1
967
967
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
1
439
439
Supply and wiring fan point as detailed above with 3 plate ceiling rose and Electronic step regulator,front cover ,modular metal box etc as per PWD specification.
-
-
-
Group A ( Short Point)
1
1237
1237
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 Nos. 3 pin 5/6 A modular socket outlet and 3 Nos. 5/ 6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
1
1176
1176
Supply and installation of suitable size MS rod type fan clamp as per IS 732 as required
1
136
136.4
Supply and Fixing Telephone point by fixing telephone socket RJ 11 Socket in suitable size Metal box in recess and making good the suface of the wall colour washing etc as required (Modular Group B )
1
380
380
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
-
-
-
2 Pair
15
405
27
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
-
-
-
20 mm dia
40
3200
80
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required.
-
-
-
3x1.5 sq,.mm
50
3500
70
3x2.5 sq,.mm
15
1575
105
3 x4Sq.mm
12
1872
156
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C”curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
Single pole
5
1215
243
Supplying and fixing following rating, Double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 /100mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
25 Amps
1
2313
2313
Supplying and fixing following way single pole and neutral sheet steel, MCB distribution board, 240V,on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)
-
-
-
6 way, Double door
1
1321
1321
Supply and providing the following types and power rated Lamps in the existing fittings as required
-
-
-
Normal size 20 W BC/ES retrofit CFL
1
193
193.6
Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required.
-
-
-
1200 mm sweep - 5 star rated
1
2381
2381
Supply, installation testing and commissioning of Energy efficient T5 1X28 W fluorescent tube fittings (Govt approved and reputed brands like Philips v2 vector or equivalent) including lamp wih all accessories and giving connection with 3 core PVC insulated and sheathed round Cu flex wire on wall/ceiling conforming to relevant ISS etc. as required.
2
1840
920.15