Kerala Police Housing And Construction Corporation Limited Tender

... More
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kerala Police Housing And Construction Corporation Limited - KPHCCL Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date17 Feb 2025
Closing Soon3 Mar 2025
Tender Amount₹ 4,68,25,217 
Notes
Download

AI Insights

Class Of Bidder
... View More
A Class & above
Technical Capacity
... View More
For works from Rs. 5 lakhs to 75 lakhs, the required prior work experience is sufficient practical experience for a diploma holder in Civil Engineering. For works from Rs.75 lakhs up to 150 lakhs, no specific prior work experience is mentioned for the Engineering Graduate and the diploma holder. For works from Rs.150 lakhs to Rs.250 lakhs, the required prior work experience is a minimum of 3 years for the Works Manager and a minimum of 1 year for the Site Engineers. For works from Rs.250 lakhs to Rs.500 lakhs, the required prior work experience is a minimum of 5 years for the Works Manager and a minimum of 2 years for the Site Engineers. The value and percentage of similar works completed is not available.

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
50.6.1.8 Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in: CM 1:6 ( 1 cement : 6 coarse sand etc complete

6.91

-

-

... More
50.6.1.9 Solid block masonry using pre cast solid blocks( Factory made) of size 40x20x15 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level with thickness 15cm in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete

3.46

-

-

... More
50.6.3.2 Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete

2.52

-

-

... More
5.9.5 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

107.73

-

-

... More
5.9.19 Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges

37.12

-

-

... More
5.3 Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15sup0/sup landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).

14.27

-

-

... More
5.22A.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more

1950

-

-

... More
13.1.2 12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand).

4201.13

-

-

... More
13.16.1 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)

2486.18

-

-

... More
14.72 Providing and fixing double scaffolding system (cup lock type) on the exterior side, upto seven story hight made with 40 mm dia. M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staricase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required location with essential safety features for the workmen etc. complete as per directions and approval of Engineer- in Charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. Note:- This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done .

192

-

-

... More
13.7.1 12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)

653.12

-

-

... More
13.21 Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.

15348.32

-

-

... More
11.41.3 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 800x 800 mm

1789.7

-

-

... More
11.48.2 Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mm

2075.02

-

-

... More
11.43 Fixing glazed/ Ceramic/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive ( Water based) conforming to IS : 15477, in average 3 mm thickness.

875

-

-

... More
13.26 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.

402.8

-

-

... More
13.48.1 Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm

6687.31

-

-

... More
OD54673/2024-2025 Providing and laying vitrified matt finished bathroom floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid with Tile fixing Polymer modified adhesive mortar, in average 6 mm thickness, including grouting of joints etc., complete. Size of Tile 600 x 600 mm.

285.32

-

-

... More
OD54674/2024-2025 Providing and laying vitrified bathroom wall tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid with Tile fixing chemical adhesive, in average 6 mm thickness, including grouting of joints etc.complete. Size of Tile 600 x 600 mm.

436.08

-

-

... More
OD54791/2024-2025 Supplying and Providing 2k water proofing compound coating 2 coats for Roof top terrace of approved make @ 2kg/m2 of mix floated hard and troweled smooth including all labour, material, conveyance charges etc complete (modified)<

721.4

-

-

... More
8.2.2.1 Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shadeArea of slab upto 0.50 sqm

14.52

-

-

... More
12.45.1 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum plain board conforming to IS : 2095-Part 1

423

-

-

... More
OD54969/2024-2025 Providing and fixing Gypsum Step ceiling with width/ depth less than or equal to 300 mm as per approved design.Frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 ,ie, perimeter channels 0.5 mm thick 27 mm high having flanges of 20 and 30 mm long to be fixed as per design intent and 12.5 mm thick tapered edge gypsum plain board to be fixed on to the framework using 25 mm long drywall screw.Finish the joints using jointing compound and joint tap as per manufacture specification.Including cost and conveyance of all materials labor charges etc.complete as per direction of Engineer-in-charge. The visible Vertical Sides will be measured .

44.2

-

-

... More
10.16.1 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes

1595.1

-

-

... More
13.61.1 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work

93.81

-

-

... More
10.28 Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)

271.04

-

-

... More
21.1.1.2 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)

70

-

-

... More
21.1.2.2 For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)

20

-

-

... More
21.3.1 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness

30

-

-

... More
OD56348/2024-2025 Providing and fixing Ist quality cladding tile (thickness to be specified by the manufacturer), of approved make, in all colours, shades of any size as approved by Engineer -in-Charge, g, laid with on polymer modified adhesive mortar, including weather sealant etc., complete.

234.36

-

-

... More
OD56380/2024-2025 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering for screeding -1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 12 mm nominal size)

86.52

-

-

... More
PARTITION WORKS

-

-

-

... More
9.105.5 Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with Zinc coating of 120 gms/ (both side inclusive), consisting of floor and ceiling channel 50 mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture's specificationand direction of engineer in charge all complete.66 mm overall thickness partition using 8 mm thick double skin multipurpose cement bonded wood particle board manufactured as per IS: 14276 with suitable cement bonded board screws

651.56

-

-

... More
13.26 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.

2139.12

-

-

... More
13.48.1 Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm

2139.12

-

-

... More
50.9.11.2 Providing and fixing Thomson Multi wood board or equivalent make paneling 18 mm thick, to frame, backing or studding with screws etc. complete (Frames, backing or studding to be paid separately)as per the direction of site Engineer-in-charge. Net Total 144.430sqm @2452.08/sqm 354153.91

144.43

-

-

... More
OD56243/2024-2025 Engaging Man Labour - Carpenter

8

-

-

... More
OD56244/2024-2025 Providing and Rose Gold Handle

30

-

-

... More
OD56245/2024-2025 Providing and fixing stainless steel handle 4

30

-

-

... More
OD56246/2024-2025 Providing and fixing Ebco Autoclose Uro hinges

60

-

-

... More
OD56247/2024-2025 Providing and fixing Tele Slider

24

-

-

... More
OD56248/2024-2025 Providing and fixing edge band

100

-

-

... More
OD56249/2024-2025 Providing and fixing VEOSYS Hinges soft close

36

-

-

... More
9.157.1 Providing and fixing Pre-laminated medium density fibre board IS:14587:1998 marked, with one side decorative lamination other side balancing lamination Grade-I (exterior grade) in shelves with screws and fittings wherever required, edges to be sealed with PVC edge bending tape 2.00 mm thick of approved brand (fittings to be paid separately).Pre-laminated with decorative lamination one side and other side balancing laminaion exterior Grade-I MDF Board 18mm thick confirming to IS:14587.

106.47

-

-

... More
26.24.1 Providing and fixing in position wall panelling at all heights with integral densified calcium silicate panels/tiles of size 595 x 595mm, having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity 0.043 W/m K as per ASTM 518:1991, comprising of a frame made from especially fabricated galvanised mild steel sheet 0.50 mm thick pressed section (galvanizing @120 grams per sqm including both sides) i.e.vertical studs of size 48 x 34 x 36 mm are placed at 600mm center to center in a floor and ceiling channel section of size 50 x 32m fixed to the floor and soffit at 600mm centers using 12mm dia,50mm long wedge type expanded zinc alloy dash fastner with 10mm bolt. This same channel is then to be fixed in horiziontal direction at 600mm center to center so as to form a grid of 600mm x 600mm. Glasswool of 50mm thickness is then to be inserted in the slots and finally calcium silicate non combustible panels/tiles are to be screw fixed with self tapping pan head nickel coated mild steel screws of size 13 x 3.2mm on to this grid leaving an even groove of 1 mm between the panels. The joints between the panels are to be duly jointed and finished using recommended jointing calcium silicate based compound and fiber joint tape roll 50mm wide (90 metre )roll and two coats of primer suitable for panelling as per manufacturer's specification as per direction of Engineer-in-Charge all complete.With 15 mm thick fully perforated square/butt edge light weight calcium silicate panels/ tiles

21.84

-

-

... More
DOORS WINDOWS

-

-

-

... More
OD54704/2024-2025 Toughened Glass Door : Providing and fixing Double door (150 x230 cm) of 12mm thick Toughened glass door (Saint Gobain or Equivalent) with (Dormakaba or Equivalent) patch fittings (Floor Spring, Top patch, pivot Pin, Bottom patch, Corner lock, Handle- Dorma TGDIH 25 x 350 mm Stainless Steel 304 H-Type Glass Door Handle - Satin Finish ). Including all cost and conveyance of materials, labour etc. complete.

4

-

-

... More
OD54705/2024-2025 Toughened Glass Door : Providing and fixing Double door (200 x230 cm) of 12mm thick Toughened glass door (Saint Gobain or Equivalent) with (Dormakaba orEquivalent) patch fittings (Floor Spring, Top patch, pivot Pin, Bottom patch, Corner lock, Handle- Dorma TGDIH 25 x 350 mm Stainless Steel 304 H-Type Glass Door Handle - Satin Finish ). Including all cost and conveyance of materials, labour etc. complete.

1

-

-

... More
OD54706/2024-2025 Supplying, Providing and fixing 12mm thick Toughened glass(Saint Gobain) Partition System with 40 x 20 mm or nearest size Stainless steel Profile and accessories, fixing to masonry or concrete, as per drawing /instruction of Engineer in charge .Including all cost and conveyance of materials, labour etc complete.

181.81

-

-

... More
OD54707/2024-2025 Providing and fixing glazing in uPVC door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. With float glass panes of 5.50 mm thickness

131.94

-

-

... More
9.1.1 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood

0.6

-

-

... More
9.121 Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of crosssection 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.

158.4

-

-

... More
9.122.1 Providing and fixing to existing door frames.30 mm thick Glas Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS : 14856, including fixing to frames.

37.8

-

-

... More
9.147F.1 Providing and fixing factory made uPVC white colour sliding glazed door comprising of uPVC multi-chambered frame with in-built roller track andsash extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension uPVC extruded glazing beads, uPVC extruded interlock and uPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle with key on one side of extreme panels along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) cresent lock (if required), stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in- Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Two track two panels sliding door made of (big series) frame 67 x 50 mm & sash 46 x 82 mm both having wall thickness of 2.3 +/- 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door above 2.00 sqm upto 5.00 sqm)

5.04

-

-

... More
9.165.1 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete.125 mm

10

-

-

... More
9.74.1 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete:250x10 mm

35

-

-

... More
9.74.2 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete:200x10 mm

45

-

-

... More
9.74.3 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete:150x10 mm

30

-

-

... More
9.74.4 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete:100x10 mm

45

-

-

... More
OD56233/2024-2025 Supplying and fixing 300 mm Ornamental brass type Door Aldrop

25

-

-

... More
OD56234/2024-2025 Providing and fixing bright finished Stainless Steel Tower Bolts (barrel type) with necessary screws etc. complete: 250 x 10 mm (9.74.1 modified)

25

-

-

... More
OD56235/2024-2025 Providing and fixing bright finished Stainless Steel Tower Bolts (barrel type) with necessary screws etc. complete: 200x10 mm (9.74.2 modified )

25

-

-

... More
OD56236/2024-2025 Providing and fixing GODREJ (or equivalent) Silver 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. (modified)

25

-

-

... More
PLUMBING AND SANITARY

-

-

-

... More
17.1.1 Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests

3

-

-

... More
17.3.1 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid

19

-

-

... More
17.4.1 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required:One urinal basin with 5 litre white P.V.C. automatic flushing cistern

12

-

-

... More
17.7.4 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap

20

-

-

... More
17.78 Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/6 litre (adjustable to 4 litre /8 litres), including seat cover, and cistern fittings, nuts bolts and gasket etc complete.

1

-

-

... More
17.81 Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge.

2

-

-

... More
OD54778/2024-2025 Providing and fixing C.P. brass pillar tap (Jaguar or equivalent )of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore

20

-

-

... More
OD54779/2024-2025 Constructing and providing RCC manhole 50 x 50 x 60cm inner dimension including earth work with 30 cm work clearance PCC 1:4:8 using 40 mm metal 10 cm thick for base RCC 1:2:4 using 20 mm metal for 20cm thick for sides and 10 cm thick base with 11 cm thick pre cast cover provision for inlet and out let connection forming channels in cc 1:3:6 at bottom, plastering with flush coat inside cutting groove for cover slab ,handling grip using 12 mm bar etc complete

2

-

-

... More
OD54781/2024-2025 Constructing and providing RCC manhole 75 x 75 x 120cm inner dimension including earth work with 30 cm work clearance PCC 1:4:8 using 40 mm metal 10 cm thick for base RCC 1:2:4 using 20 mm metal for 20cm thick for sides and 10 cm thick base with 11 cm thick pre cast cover provision for inlet and out let connection forming channels in cc 1:3:6 at bottom, plastering with flush coat inside cutting groove for cover slab ,handling grip using 12 mm bar etc complete

1

-

-

... More
OD54782/2024-2025 Constructing and providing RCC manhole 60 x 60 x 90cm inner dimension including earth work with 30 cm work clearance PCC 1:4:8 using 40 mm metal 10 cm thick forbase RCC 1:2:4 using 20 mm metal for 20cm thick for sides and 10 cm thick base with 11 cm thick pre cast cover provision for inlet and out let connection forming channels in cc 1:3:6 at bottom, plastering with flush coat inside cutting groove for cover slab ,handling grip using 12 mm bar etc complete

1

-

-

... More
OD54784/2024-2025 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore ( Jaquar or equivalent) (modified)

60

-

-

... More
OD54785/2024-2025 Providing and fixing Soap Dish Holder(jaguar item code ACN-CHR-1131N or equivalent)

30

-

-

... More
OD54786/2024-2025 Supplying and fixing CP Health Faucet superior quality ( Jaguar or equivalent make ) including cost of materials and labour charges etc. complete as per the direction of site Engineer-in-charge. (modified)

30

-

-

... More
OD54787/2024-2025 Supplying and fixing PVC Floor Trap 100mmx75mm size without Jali including cutting open, fixing through RCC slabs and making good the damages

40

-

-

... More
OD54788/2024-2025 Providing and fixing SS grating of approved quality. Rectangular type with openable circular lid : 150 mm nominal size square 100 mm diameter of the inner hinged round grating

40

-

-

... More
OD54789/2024-2025 Providing and fixing special type brass bib cock short body of approved make and quality as per direction of Engineer-in-charge

28

-

-

... More
17.73.1 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm. weighing not less than 170 gms

25

-

-

... More
17.9.1 Providing and fixing kitchen sink with C. I brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required:White glazed fire clay kitchen sink of size 600x450x250 mm

2

-

-

... More
50.18.8.3.1 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 25 mm pipe 12 kgf/cm2

154

-

-

... More
50.18.8.4.1 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 10Kgf/cm2

124

-

-

... More
50.18.8.6.1 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 10 kgf/cm2

65

-

-

... More
50.18.8.7.1 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work including cutting chases and making good the wall etc. 63 mm pipe 6 Kgf/cm2

70

-

-

... More
50.18.8.8.1 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 75 mm pipe 6 Kgf/cm2

50

-

-

... More
50.18.8.9.1 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2

84

-

-

... More
50.18.9.10.1 Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2

52

-

-

... More
50.18.9.13.1 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 12 Kgf/ cm2- External work- exposed on wall

64

-

-

... More
50.18.9.15.1 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 40 mm dia 10Kgf/cm2- External work- Exposed on wall

64

-

-

... More
50.18.9.17.1 Providing and fixing PVC pipes including fixing the pipe with clamps/ clip at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 6 Kgf/cm2 - External work - Exposed on wall

45

-

-

... More
50.18.9.19.1 Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall

64

-

-

... More
50.18.9.20.1 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Elbow

20

-

-

... More
50.18.9.20.2 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -63 dia 45 degree Elbow

15

-

-

... More
50.18.9.20.3 Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Door Elbow

10

-

-

... More
50.18.9.20.4 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Bend

15

-

-

... More
50.18.9.20.5 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes including jointing with PVC solvent cement - 63x63x63 mm dia Tee

10

-

-

... More
50.18.9.21 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Elbow

10

-

-

... More
50.18.9.21.2 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia 45 degree Elbow

10

-

-

... More
50.18.9.21.3 Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia Door Elbow

10

-

-

... More
50.18.9.22.1 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow

15

-

-

... More
50.18.9.22.2 Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia 45 degree Elbow

15

-

-

... More
50.18.9.22.3 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement-110 mm dia Door Elbow

15

-

-

... More
50.18.9.22.4 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend

30

-

-

... More
50.18.9.22.5 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes including jointing with PVC solvent cement 110x110x110 mm dia Tee

45

-

-

... More
50.18.9.22.6 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x110x110 mm dia Door tee

30

-

-

... More
OD56126/2024-2025 Providing and Fixing PVC moulded fittings / accessories for Rigid PVC pipes including jointing with PVC solvent cement - 110 mm dia Y

15

-

-

... More
OD56127/2024-2025 Providing and fixing in position C.P towel rail, including cost of all materials ( wooden plugs, steel screws etc.) and labour charges etc. complete. Make: Jaquar / Hind ware / Parryware / Equivalent etc.

22

-

-

... More
OD56128/2024-2025 Providing and fixing C.P. brass long body bib cock (Jaguar or equivalent )of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore

22

-

-

... More
OUTSIDE YARD WORK

-

-

-

... More
2.6.1 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

736.47

-

-

... More
16.68 Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.

1112.87

-

-

... More
OD56206/2024-2025 Providing and fixing Neelgiri/Mexican grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and even, watering with sprinkler

102.9

-

-

... More
OD56207/2024-2025 Engaging Tipper lorry for shifting earth from site, yard with in distance of 2.5 km for shifting for the earth from yard to site for Back filling including all cost for driver salary , Oil maintenance etc. complete.

5

-

-

... More
OD56208/2024-2025 Engaging JCB for earth cutting, removing root of the big trees and site leveling including rent labor charges, fuel, batá etc. complete

50

-

-

... More
SEPTIC TANK

-

-

-

... More
2.8.1 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

87.75

-

-

... More
2.26.1 Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil

43.88

-

-

... More
5.9.1 Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

8.08

-

-

... More
4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

2.6

-

-

... More
5.1.2 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size

7.2

-

-

... More
5.9.2 Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

127.2

-

-

... More
5.9.3 Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

30.2

-

-

... More
5.2.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)

12.72

-

-

... More
5.3 Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15sup0/sup landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).

5.21

-

-

... More
5.22.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

3015

-

-

... More
13.1.1 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

220.04

-

-

... More
13.21 Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.

1540.28

-

-

... More
19.32.1 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

1

-

-

... More
19.18.3 Supplying and fixing C.I with out frame for manholes:560 mm diameter ( heavy duty) the weight of the cover to be not less than 108 kg

2

-

-

... More
50.18.9.19.1 Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall

45

-

-

... More
50.18.9.22.1 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow

15

-

-

... More
50.18.9.22.2 Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia 45 degree Elbow

10

-

-

... More
50.18.9.22.3 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement-110 mm dia Door Elbow

10

-

-

... More
50.18.9.22.4 : Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend

25

-

-

... More
50.18.9.22.5 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes including jointing with PVC solvent cement 110x110x110 mm dia Tee

20

-

-

-

-

-

... More
2.26.1 Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil

106.92

-

-

... More
2.8.1 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

240.57

-

-

... More
4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

8.32

-

-

... More
5.37.1 Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in -charge. Note:- Cement content considered in this item is @330 kg/cum. Excess /less cement used as per design mix is payable/recoverable separately.All wiork upto plinth level

58.03

-

-

... More
5.9.1 Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

14.48

-

-

... More
5.9.2 Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

233.28

-

-

... More
5.9.3 Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

69.84

-

-

... More
5.22.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

6963.84

-

-

... More
13.1.1 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

496.08

-

-

... More
OD55283/2024-2025 Supplying and Providing 2k water proofing compound coating 2 coats for Toilet floor and Wall area of approved make @ 2kg/m2 of mix floated hard and troweled smooth including all labour, material, conveyance charges etc. complete (modified)

308.88

-

-

... More
19.18.3 Supplying and fixing C.I with out frame for manholes:560 mm diameter ( heavy duty) the weight of the cover to be not less than 108 kg

8

-

-

... More
50.18.9.9.1 Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2

10

-

-

... More
50.18.9.22.2 Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia 45 degree Elbow

10

-

-

... More
50.18.9.22.4 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend

10

-

-

... More
OD56132/2024-2025 Supplying and fixing 3 core 2.50mm weatherproof submersible cable with ISI marked in 20mm pipe Net Total 25.000metre

25

-

-

... More
OD56133/2024-2025 Supply, installation, testing and commissioning of 1.50 HP 18 stage Bore-well submersible pump set ISI marked (Kirlosker/ Crompton/ V-Guard/ Texos make) including panel board and other necessary accessories etc. complete

2

-

-

... More
OVER HEAD WATER TANK

-

-

-

... More
5.9.2 Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

79.6

-

-

... More
5.2.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)

7.96

-

-

... More
5.22A.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more

1034.8

-

-

... More
13.1.1 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

121.3

-

-

... More
13.21 Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.

849.1

-

-

... More
OD55136/2024-2025 Providing and fixing powder coated Galvalume Trafford sheet 0.45 mm thick up to any pitch and fixing with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. plain and bitumen washers or with self drilling fastener and EPDM washers etc. complete (excluding the cost of purlins, rafters and trusses), including cutting sheets to size and shape wherever required.

41.7

-

-

... More
10.16.1 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes

255.35

-

-

... More
13.61.1 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work

24.91

-

-

... More
RETAINING WALL AND COMPOUND WALL

-

-

-

... More
2.9.1 Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock

79.63

-

-

... More
4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

6.64

-

-

... More
5.2.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)

27.65

-

-

... More
5.9.1: Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

44.24

-

-

... More
5.9.2 Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

276.5

-

-

... More
5.1.2 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size

19.91

-

-

... More
5.22.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

5231.6

-

-

... More
13.1.1 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

138.25

-

-

... More
50.18.8.9.1 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2

30

-

-

... More
10.16.1 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes

150

-

-

... More
INTERNAL ELECTRIFICATION

-

-

-

... More
1.10.3 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C

328

-

-

... More
1.55.3 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C

112

-

-

... More
1.14.1 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire

1740

-

-

... More
1.14.2 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

2015

-

-

... More
1.14.4 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 6 Sq.mm + 1 x 6 sq.mm earth wire

250

-

-

... More
1.14.9 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 6 sq. mm + 2 X 6 sq. mm earth wire

160

-

-

... More
1.14.10 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 10 sq. mm + 2 X 6 sq. mm earth wire

125

-

-

... More
1.18.2 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair

660

-

-

... More
1.18.3 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.4 Pair

1180

-

-

... More
1.19 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.

1200

-

-

... More
1.24.1 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch

776

-

-

... More
1.24.2 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.2 way 5/6 amps switch

40

-

-

... More
1.24.4 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet

448

-

-

... More
1.24.3 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch

52

-

-

... More
1.24.5 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet

52

-

-

... More
1.24.6 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet

82

-

-

... More
1.24.7 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet

36

-

-

... More
1.24.8 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push

20

-

-

... More
1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

67

-

-

... More
1.26 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required

102

-

-

... More
1.27.1 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)

276

-

-

... More
1.27.2 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)

143

-

-

... More
1.27.3 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm)

82

-

-

... More
1.27.4 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)

112

-

-

... More
1.27.5 Supplying and fixing following size/ modules, GI box alongwith modular base &cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)

82

-

-

... More
1.27.6 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.12 Module (200mmX150mm)

22

-

-

... More
1.12 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required

1250

-

-

... More
1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).

94

-

-

... More
1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.

8

-

-

... More
2.18 Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

27

-

-

... More
1.21.1 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

2240

-

-

... More
1.21.2 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

2000

-

-

... More
1.21.3 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm

1000

-

-

... More
1.11 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.

20

-

-

... More
OD55190/2024-2025 Supply, installation testing and commissioning of floor pop up boxes for installation of power sockets , including supply of lid, cover and all accessories complete. (Equivalent to Legrand Cat no 6896 34 and accessories or equivalent)

4

-

-

... More
OD55193/2024-2025 Supply, installation testing and commissioning of pop up boxes 8 module for installation of power sockets and data points for work table, including supply of lid, cover and all accessories complete. (Equivalent to Legrand Cat no 6540 15 and accessories or equivalent)

5

-

-

... More
OD55211/2024-2025 Supply, laying and installation of following underfloor raceways manufactured from 1.5mm thick cover and base (including partitions for multi-compartment raceways), zero spangle pre-galvanized sheet steel with 275 GSM coating mass, cover and base MIG welded together. the length of raceways shall be 2.5 meters per length with single accessory acting as duct connector cum fastening clamp to ease work at site, vertical access box, etc. load bearing capacity in line with EN 50085-2-2. with all accessories of trunking connecting shackle etc where required in screed floor as approved by consultant/ client/Architect at site including clamping & closing the open ends temporarily by suitable end covers against entry of dust or any foriegn materials. Installation rates of GI under floor ducting should be inclusive of necessary hardware and arrangement required for fixing of trunk with duct connector and fastening clamp. This activity also includes connecting shackles along with associated accesories and all other accessories as required for complete installation. (Make : OBO Bettermann or equivalent). Necessary cutting of floors as per site requirements for fixing the same shall not be considered in this scope of work. 50 x 38 mm, no compartment 1.5mm thickness, including connection clamps & metal duct

50

-

-

... More
OD55212/2024-2025 Supply, laying and installation of following underfloor raceways manufactured from 1.5mm thick cover and base (including partitions for multi-compartment raceways), zero spangle pre-galvanized sheet steel with 275 GSM coating mass, cover and base MIG welded together. the length of raceways shall be 2.5 meters per length with single accessory acting as duct connector cum fastening clamp to ease work at site, vertical access box, etc. load bearing capacity in line with EN 50085-2-2. with all accessories of trunking connecting shackle etc where required in screed floor as approved by consultant/ client/Architect at site including clamping & closing the open ends temporarily by suitable end covers against entry of dust or any foriegn materials. Installation rates of GI under floor ducting should be inclusive of necessary hardware and arrangement required for fixing of trunk with duct connector and fastening clamp. This activity also includes connecting shackles along with associated accesories and all other accessories as required for complete installation. (Make : OBO Bettermann or equivalent). Necessary cutting of floors as per site requirements for fixing the same shall not be considered in this scope of work. 75 x 38 mm, no compartment 1.5mm thickness, including connection clamps & metal duct

60

-

-

... More
OD55214/2024-2025 Supply, laying and installation of following underfloor raceways manufactured from 1.5mm thick cover and base (including partitions for multi-compartment raceways), zero spangle pre-galvanized sheet steel with 275 GSM coating mass, cover and base MIG welded together. the length of raceways shall be 2.5 meters per length with single accessory acting as duct connector cum fastening clamp to ease work at site, vertical access box, etc. load bearing capacity in line with EN 50085-2-2. with all accessories of trunking connecting shackle etc where required in screed floor as approved by consultant/ client/Architect at site including clamping & closing the open ends temporarily by suitable end covers against entry of dust or any foreign materials. Installation rates of GI under floor ducting should be inclusive of necessary hardware and arrangement required for fixing of trunk with duct connector and fastening clamp. This activity also includes connecting shackles along with associated accessories and all other accessories as required for complete installation. (Make : OBO Bettermann or equivalent). Necessary cutting of floors as per site requirements for fixing the same shall not be considered in this scope of work. 100 x 38 mm, no compartment 1.5mm thickness, including connection clamps & metal duct

40

-

-

... More
OD55215/2024-2025 Supply, laying and installation of following underfloor raceways manufactured from 1.5mm thick cover and base (including partitions for multi-compartment raceways), zero spangle pre-galvanized sheet steel with 275 GSM coating mass, cover and base MIG welded together. the length of raceways shall be 2.5 meters per length with single accessory acting as duct connector cum fastening clamp to ease work at site, vertical access box, etc. load bearing capacity in line with EN 50085-2-2. with all accessories of trunking connecting shackle etc where required in screed floor as approved by consultant/ client/Architect at site including clamping & closing the open ends temporarily by suitable end covers against entry of dust or any foreign materials. Installation rates of GI under floor ducting should be inclusive of necessary hardware and arrangement required for fixing of trunk with duct connector and fastening clamp. This activity also includes connecting shackles along with associated accessories and all other accessories as required for complete installation. (Make :OBO Bettermann or equivalent). Necessary cutting of floors as per site requirements for fixing the same shall not be considered in this scope of work. 100 x 38 mm, 2 compartment 1.5mm thickness, including connection clamps & metal duct

110

-

-

... More
OD55216/2024-2025 Supply, laying and installation of following underfloor raceways manufactured from 1.5mm thick cover and base (including partitions for multi-compartment raceways), zero spangle pre-galvanized sheet steel with 275 GSM coating mass, cover and base MIG welded together. the length of raceways shall be 2.5 meters per length with single accessory acting as duct connector cum fastening clamp to ease work at site, vertical access box, etc. load bearing capacity in line with EN 50085-2-2. with all accessories of trunking connecting shackle etc where required in screed floor as approved by consultant/ client/Architect at site including clamping & closing the open ends temporarily by suitable end covers against entry of dust or any foreign materials. Installation rates of GI under floor ducting should be inclusive of necessary hardware and arrangement required for fixing of trunk with duct connector and fastening clamp. This activity also includes connecting shackles along with associated accessories and all other accessories as required for complete installation. (Make : OBO Bettermann or equivalent). Necessary cutting of floors as per site requirements for fixing the same shall not be considered in this scope of work. 150 x 38 mm, 2 compartment 1.5mm thickness, including connection clamps & metal duct Ne

60

-

-

... More
OD55218/2024-2025 Supply, laying and installation of following underfloor raceways manufactured from 1.5mm thick cover and base (including partitions for multi-compartment raceways), zero spangle pre-galvanized sheet steel with 275 GSM coating mass, cover and base MIG welded together. the length of raceways shall be 2.5 meters per length with single accessory acting as duct connector cum fastening clamp to ease work at site, vertical access box, etc. load bearing capacity in line with EN 50085-2-2. with all accessories of trunking connecting shackle etc where required in screed floor as approved by consultant/ client/Architect at site including clamping & closing the open ends temporarily by suitable end covers against entry of dust or any foreign materials. Installation rates of GI under floor ducting should be inclusive of necessary hardware and arrangement required for fixing of trunk with duct connector and fastening clamp. This activity also includes connecting shackles along with associated accessories and all other accessories as required for complete installation. (Make : OBO Bettermann or equivalent). Necessary cutting of floors as per site requirements for fixing the same shall not be considered in this scope of work. 200 x 38 mm, 3 compartment 1.5mm thickness, including connection clamps & metal duct

120

-

-

... More
OD55219/2024-2025 Supply and fixing of UL certified CAT-6 Information Outlet for 1000Mbps having spring shutter / dust cover face plate with one number of RJ45 keystone socket + SMB including termination charges etc. Preferred Make: Commscope, Actassi, Belden, Molex, R&M, Honeywell or equivalent

160

-

-

... More
1.53.1 Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable

3660

-

-

... More
OD55585/2024-2025 Supply, Installation Testing and Commissioning of 6W, 600 lumens, integral LED bulk head fitting with 4000K LED and constant current electronic driver with all fixing materials for mounting on wall. LED light fittings suitable for operation on 230V, single phase, AC supply. The fitting shall be supplied with all fixing material such as brackets, nuts, bolts etc. as required for installation. (Make: Philips Endura Bulkhead WT202W- LED6S NW-PSU-S2-PC or equivalent)

30

-

-

... More
OD55593/2024-2025 Supply, Installation Testing and Commissioning of 18W - 1600 Lumen - LED surface mounted down lighter with 4000K LED and constant current electronic driver complete with all fixing materials for mounting on ceiling. LED light fittings suitable for operation on 230V, single phase, AC supply. The fitting shall be supplied with all fixing material such as brackets, nuts, bolts etc. as required for installation. (Make: PHILIPS-Cirrus MINI PRO SM251C-LED20S- 4000-PSU-OD-WH or equivalent)

54

-

-

... More
OD55594/2024-2025 Supply, Installation Testing and Commissioning of 16W - 1600 Lumen - LED surface mounted down lighter with 4000K LED and constant current electronic driver complete with all fixing materials for mounting on ceiling. LED light fittings suitable for operation on 230V, single phase, AC supply. The fitting shall be supplied with all fixing material such as brackets, nuts, bolts etc. as required for installation. (Make: PHILIPS-Cirrus MINI PRO SM200C-LED16S- 4000-PSU-OD-WH or equivalent)

108

-

-

... More
OD55583/2024-2025 Supply and providing of 40W LED Batten in surface/ suspended mounting, Ingress protection of IP20, Integrated batten in aluminium extruded housing having color temperature of 4000K,THD <10%,CRI>70 ,Internal surge protection of 4KV,50000 burning hours, Operating Temperature: -10 degree to 50 degree, Luminaire efficacy < 90 Lumens/Watts (Model: Crompton/Havells/Philips/Lighting Solutions)

34

-

-

... More
OD56044/2024-2025 Supply, Installation Testing and Commissioning of 20 W recess mounted LED fixture . LED light fittings suitable for operation on 230V, single phase, AC supply. The fitting shall be supplied with all fixing material such as brackets, nuts, bolts etc. as required for installation. (Make: Philips DN 296B LED 20S or equivalent)

50

-

-

... More
OD56047/2024-2025 Supply, Installation Testing and Commissioning of 40 Watts 2 x 2 feet recess mounted LED fixture . LED light fittings suitable for operation on 230V, single phase, AC supply. The fitting shall be supplied with all fixing material such as brackets, nuts, bolts etc. as required for installation. (Make: Philips RC380B LED42S-6500 G5 L60W60 PSU OD or equivalent)

10

-

-

... More
OD56048/2024-2025 Supply, Installation Testing and Commissioning of Suspended Aluminum profile lights with 18W/mtr LED strip lights with drive and all accessories complete. . LED light fittings suitable for operation on 230V, single phase, AC supply. The fitting shall be supplied with all fixing material such as brackets, nuts, bolts etc. as required for installation. (Make: Luker LPL 70501M or equivalent)

100

-

-

... More
OD56057/2024-2025 Supply, Installation Testing and Commissioning of Recessed/concealed Aluminium profile lights with 12W/mtr LED strip lights with drive and all accessories complete.. LED light fittings suitable for operation on 230V, single phase, AC supply. The fitting shall be supplied with all fixing material such as brackets, nuts, bolts etc. as required for installation. (Make: Luker LPL 1809 or equivalent)

46

-

-

... More
OD56058/2024-2025 Supply, Installation Testing and Commissioning of 15 W surface mounted LED fixture . LED light fittings suitable for operation on 230V, single phase, AC supply. The fitting shall be supplied with all fixing material such as brackets, nuts, bolts etc. as required for installation. (Make: Philips SM200C LED16S or equivalent)

35

-

-

... More
OD56059/2024-2025 Supply, Installation Testing and Commissioning of Surface mounted 30W LED down lighter fixture for atrium/Lobby area . LED light fittings suitable for operation on 230V, single phase, AC supply. The fitting shall be supplied with all fixing material such as brackets, nuts, bolts etc. as required for installation. (Make: Luker Corvus COB 45 or equivalent)

16

-

-

... More
OD56060/2024-2025 Supply and installation of Tracks for installation of track lights including connectors wherever necessary. The fitting shall be supplied with all fixing material such as brackets, nuts, bolts etc. as required for installation. (Make: Luker LTM1/2 or equivalent)

12

-

-

... More
OD56061/2024-2025 Supply, Installation Testing and Commissioning of 18W Track mounted lights . LED light fittings suitable for operation on 230V, single phase, AC supply. The fitting shall be supplied with all fixing material such as brackets, nuts, bolts etc. as required for installation. (Make: Luker LSPT18 or equivalent)

31

-

-

... More
90.15.4.9 Supply Conveyance, installation, testing and commissioning of 150W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)

4

-

-

... More
OD55267/2024-2025 Supply,installation,testing and commissioning of 1200mm sweep, BEE 5 star rated ceiling fan with Bruss Less Direct Current ( BLDC) motor, class of insulation:B,3 nos blades,30cm long down rod,2 nos canopies, shackle kit, safety rope,copper winding,power factor not less than .9,service value (CMM/W) minimum 6.85,Air delivery 215 CMM,350RPM(tolerance as per IS 374-2019),THD less than 10%,remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts,washers,temperature,rise=75 degree C (Max),insulation resistance more than 2 mega ohm, suitable for 230V,50Hz,single phase AC supply ,earthing etc complete as required. (Model:Atomberg Renesa+ or equivalent )

43

-

-

... More
OD55268/2024-2025 Supply, installation, testing and commissioning of 400mm sweep wall fan with energy efficient BLDC motor ,giving connection etc complete as required.

4

-

-

... More
OD55281/2024-2025 Supply, installation, testing and commissioning of 300 mm sweep light duty exhaust fan complete with bird guard, louvers etc and other fixing accessories as required.(Havells model Turbo Force, Bajaj model No.Freshee mk2 300mm, Crompton model no. TA-300-AG, Usha model No.JET DELUXE or equivalent)

10

-

-

... More
PANEL&DISTRIBUTION BOARD

-

-

-

... More
OD56281/2024-2025 Supplying, installation, testing and commissioning of cubicle type prewired Main Switch Board Panel suitable for 415 Volt, 3 phase, 4 wire 50 HZ AC supply system, floor mounted, fabricated in compartmentalized design from CRCA steel of 2 mm thick for frame work and covers, 3 mm thick for gland plates, including cleaning and finishing powder coated, dust and vermin proof complete with 7 tank process having finishing powder coated, dust and vermin proof complete with 7 tank process having extensible type TPN aluminium alloy bus bar of high conductivity, with base frame of M.S. channel section of not less than 75 mm x 50 mmx5mm thick, copper earth bar of size 25mmx 5mm at the rear with 2 No. earth stud, complete with control wire, cable alleys, cable gland plates, including following : Incoming : 15 A, 4P MCCB, 35 KA with thermal magnetic release - 2 Nos, One incomer for KSEB and one incomer for DG with Electrical interlock between the two incomers. AMF facility using programmable logic relay (EC 2 of C&S or equivalent) for auto start and stop of DG and also automatic changeover between the two power supplies. For each incomer : MFM having Ammeter, Voltmeter, kWh meter, frequency meter, P.F. meter, KW meter with 200/ 5A CTs - 2 set. ON/ OFF/ TRIP indication - 1 set. Surge Suppressor Class (B & C) - 1 no. Busbar : 4 Strip aluminium bus bar of 350 A, 415 V capacity with heat shrinkable coloured sleeves complete for withstanding 35 KA fault - 1 set. Outgoing : 160 A, 4P MCCB, 35 KA - 4 nos., 125 A, 4P MCCB, 35 KA - 2 nos., 63 A, 4P MCCB, 35 KA - 4 nos., 250 A, TPN Isolator - 1 no.

1

-

-

... More
OD56337/2024-2025 Supplying, installation, testing and commissioning of cubicle type prewired Floor Panel (SSB) suitable for 415 Volt, 3 phase, 4 wire 50 HZ AC supply system, floor mounted, fabricated in compartmentalized design from CRCA steel of 2 mm thick for frame work and covers, 3 mm thick for gland plates, including cleaning and finishing powder coated, dust and vermin proof complete with 7 tank process having extensible type TPN aluminium alloy bus bar of high conductivity, with base frame of M.S. channel section of not less than 75 mm x 50 mmx5mm thick, copper earth bar of size 25mmx 5mm at the rear with 2 No. earth stud, complete with control wire, cable alleys, cable gland plates, including following : Incoming : 200 A, TPN Isolator - 1 no, MFM having Ammeter, Voltmeter, kWh meter, frequency meter, P.F. meter, KW meter with 100/ 5A CTs - 1 set., ON/ OFF indication - 1 set. Busbar: 4 Strip aluminium bus bar of 125 A, 415 V capacity with heat shrinkable coloured sleeves complete for withstanding 35 KA fault - 1 set, Outgoing: 100 A, 4P MCCB, 25 KA - 1 nos., 63 A, 4P MCCB, 25 KA - 2 nos. 40 A, 4P MCCB, 25 KA - 4 nos.

3

-

-

... More
OD56351/2024-2025 Supplying, installation, testing and commissioning of cubicle type prewired 75 KVAR LT Capacitor Panel suitable for 415 Volt, 3 phase, 4 wire 50 HZ AC supply system, floor mounted, fabricated in compartmentalized design from CRCA steel of 2 mm thick for frame work and covers, 3 mm thick for gland plates, including cleaning and finishing powder coated, dust and vermin proof complete with 7 tank process having extensible type TPN aluminium alloy bus bar of high conductivity, with base frame of M.S. channel section of not less than 75 mm x 50 mmx5mm thick,. earth stud, complete with control wire, cable alleys, cable gland plates, including following : Incoming : 1 Set of 200A 4P MCCB 35 KA with overload, short circuit protections with adjustable settings. 1 No. power factor digital meter 1 No. APFC relay suitable for sequential operation of 8 Capacitor Banks, 1 No. Digital Ammeter with selector switch and 3 NO. 200 / 5A CTs, One Set Breaker ON / OFF / TRIP indicating lights with control MCB’s. One Set of R, Y, B phase indicating light (LED type) with 2A , SP MCB, 10KA, Bus Bar: 200 A, 415V, 3 strip, 50 KA, 50 Hz Aluminium Bus bar, Outgoing: 1x20 KVAR LT power capacitor banks. 2x15 KVAR LT power capacitor banks. 2x10 KVAR LT power capacitor banks. 2x2.5 KVAR LT power capacitor banks. 1 Nos, 40 Amps TP MCB, with equivalent TP Contactor for 20 kVAR Capacitor bank, 2 Nos, 32 Amps TP MCB, with equivalent TP Contactor for 15 kVAR Capacitor bank, 2 Nos, 32 Amps TP MCB, with equivalent TP Contactor for 10 kVAR Capacitor bank, 2 Nos, 25 Amps TP MCB, with equivalent TP Contactor for 2.5 kVAR Capacitor bank, Each capacitor bank must have 1 set of on/ off indication LED type.

1

-

-

... More
OD56360/2024-2025 Supply, Installation, Testing and commissioning of Outdoor metering cubicle in IP54 enclosure, with 4 nos 200 A Cutouts, 200A TPN Isolator, 4 nos of 200/5A class 0.5 CTs, LT TOD Meter of class 0.5S accuracy, including testing and commissioning of the energy meter and CTs from KSEB. The cubicle is to be installed on a pedestal made of GI profiles, duly connected to earth pits.

1

-

-

... More
2.3.1 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator6 way, Double door

1

-

-

... More
2.3.2 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door

2

-

-

... More
2.3.3 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door

1

-

-

... More
90.11.1.10 Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)

9

-

-

... More
90.11.1.12 Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - three phase double cover (IP 42/43)

11

-

-

... More
90.11.1.14 Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)

7

-

-

... More
90.11.1.16 Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)

3

-

-

... More
90.11.1.20 Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)

3

-

-

... More
2.2.1 Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.100 Amp, 16 KA, TPMCCB

3

-

-

... More
2.10.1 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

480

-

-

... More
2.10.3 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole

4

-

-

... More
2.10.4 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole

18

-

-

... More
2.10.5 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral

24

-

-

... More
2.11 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

100

-

-

... More
2.12.1 Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

1

-

-

... More
2.12.2 Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps

1

-

-

... More
2.13.1 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

10

-

-

... More
2.13.2 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps

18

-

-

... More
2.14.1 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps

2

-

-

... More
2.15.2 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

10

-

-

... More
2.15.3 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps

6

-

-

... More
OD56367/2024-2025 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 100 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

3

-

-

... More
OD56373/2024-2025 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 100 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps

3

-

-

... More
2.16 Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.

10

-

-

... More
2.17 Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32amps 415 volts "C" curve TP MCB complete with connections, testing and commissioning etc. as required.

6

-

-

... More
2.24.2 Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 6 way, Double door TPN MCBDB

2

-

-

... More
2.24.3 Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 8 way, Double door TPN MCBDB

2

-

-

... More
2.25 Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for tripple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.

2

-

-

... More
Uninterrupted Power Supply

-

-

-

... More
OD56389/2024-2025 Supply, installation, testing and commissioning of 15KVA/415V Online Sine Wave UPS Three Phase input Three phase output with in-built Isolation transformer, 35Ah, 12V SMF Batteries for 30 minutes back up, along with battery stand and all accessories.

1

-

-

... More
OD56402/2024-2025 Supply, installation, testing and commissioning of 10KVA/415V Online Sine Wave UPS Three Phase input Three phase output with in-built Isolation transformer, 26Ah, 12V SMF Batteries for 30 minuutes back up, along with battery stand and all accessories.

1

-

-

... More
Lightning Protection System

-

-

-

... More
OD56521/2024-2025 Providing and fixing Fully Solid Vertical Air terminals having high wind load stability as per IS/IEC -62305 part-3, tested for 100 KA 10/350 micro sec waveform in Govt approved Indian labs and certified. 2 Meter Air terminal

6

-

-

... More
OD56522/2024-2025 Providing 8mm (50sqmm) solid aluminium round conductor, meets the requirement of (IS/IEC 62305) and fixing with necessary holders at interval as specified below Horizondal conductor for parapet, fixing with weather resistant plastic holder at every 0.5 meters Vertical down conductor, fixing with weather resistant plastic holder at every 0.75 meters

320

-

-

... More
OD56523/2024-2025 Supply Installation testing and Commissioning of all materials and providingmaintenance free Earthing system comprises of 20mm dia molecularly bonded copper of 99.9% purity on low carbon steel of 3m length with copper bonding thickness of 250 microns, fault current withstand capability of 20 kA rms / 1 sec and Ipeak = 50 kA. Complete with all accessories such as SS 304 universal clamp, Impact point etc. Complete with supply & providing earth enhancing mineral compound with resistivity less than 0.2 Ωm, free from hazardous substances and providing 200x200 mm inspection chamber with heavy duty cover of bearing capacity of 50kN to cover the Earth Rod. Maintenance free Earthing / Earth Electrode

6

-

-

... More
OD56526/2024-2025 Supply Installation Testing and Commissioning of Ring Earth / Equipotential Bonding Conductor .Providing 10mm high corrosion resistant copper coated steel solid round conductor with copper coating thickness of 100microns as per IS/IEC 62305, and laying directly in ground 0.5Mtr below ground level and 1 Mtr away from the structure, around the building perimeter.

260

-

-

... More
OD56527/2024-2025 Supply and installing Test Joint to connect 8mm aluminium round conductor to earthing system, with necessary covering box, including connection to the earth pit using 10mm round Al round conductor in 25mm PVC pipe.

6

-

-

... More
LT Cables

-

-

-

... More
OD56530/2024-2025 Supply of following size 1.1 KV cross -linked polyethylene (XPLE) insulated, FRLS AL armoured conductor PVC inner sheathed , overall PVC sheathed cable in conformity to the technical specification and as per latest IS code. .3.5 core 150 sq mm

80

-

-

... More
OD56532/2024-2025 Supply of following size 1.1 KV cross -linked polyethylene (XPLE) insulated, FRLS AL armoured conductor PVC inner sheathed , overall PVC sheathed cable in conformity to the technical specification and as per latest IS code..3.5 core 95 sq mm

232

-

-

... More
OD56533/2024-2025 Supply of following size 1.1 KV cross -linked polyethylene (XPLE) insulated, FRLS AL armoured conductor PVC inner sheathed , overall PVC sheathed cable in conformity to the technical specification and as per latest IS code.4 core 25 sq mm

220

-

-

... More
OD56535/2024-2025 Supply of following size 1.1 KV cross -linked polyethylene (XPLE) insulated, FRLS AL armoured conductor PVC inner sheathed , overall PVC sheathed cable in conformity to the technical specification and as per latest IS code.4 core 16 sq mm

222

-

-

... More
OD56536/2024-2025 Supply of following size 1.1 KV cross -linked polyethylene (XPLE) insulated, FRLS AL armoured conductor PVC inner sheathed , overall PVC sheathed cable in conformity to the technical specification and as per latest IS code .4 core 10 sq mm

540

-

-

... More
OD56537/2024-2025 Supply of following size 1.1 KV cross -linked polyethylene (XPLE) insulated, FRLS AL armoured conductor PVC inner sheathed , overall PVC sheathed cable in conformity to the technical specification and as per latest IS code .2 core 10 sq mm

80

-

-

... More
OD56538/2024-2025 Supply of following size 1.1 KV cross -linked polyethylene (XPLE) insulated, FRLS armoured copper conductor PVC inner sheathed , overall PVC sheathed cable in conformity to the technical specification and as per latest IS code. .4 core 10 sq mm

140

-

-

... More
OD56540/2024-2025 Supply of following size 1.1 KV cross -linked polyethylene (XPLE) insulated, FRLS armoured copper conductor PVC inner sheathed , overall PVC sheathed cable in conformity to the technical specification and as per latest IS code..2 core 10 sq mm

340

-

-

... More
7.5.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm

72

-

-

... More
7.5.2 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 35 sq. mm and upto 95 sq. mm

4

-

-

... More
7.5.3 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 95 sq. mm and upto 185 sq. mm

74

-

-

... More
7.6.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Upto 35 sq. mm

100

-

-

... More
7.6.2 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 35 sq. mm and upto 95 sq. mm

8

-

-

... More
7.6.3 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 95 sq. mm and upto 185 sq. mm

2

-

-

... More
7.8.1 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle)

1000

-

-

... More
7.8.2 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

160

-

-

... More
7.8.3 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)

4

-

-

... More
Cable termination

-

-

-

... More
9.1.2 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm)

6

-

-

... More
9.1.24 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 95 sq. mm (45mm)

10

-

-

... More
9.1.26 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 150 sq. mm (50mm).

2

-

-

... More
9.1.32 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)

28

-

-

... More
9.1.33 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)

24

-

-

... More
9.1.34 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)

6

-

-

... More
OD54943/2024-2025 Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm)

76

-

-

... More
OD54955/2024-2025 Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 10 sq. mm (19mm)

14

-

-

... More
Cable tray

-

-

-

... More
4.1.2 Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness

160

-

-

... More
4.1.4 Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness

200

-

-

... More
4.1.6 Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.450 mm width X50 mm depth X 2.0 mm thickness

10

-

-

... More
4.1.7 Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.600 mm width X 50 mm depth X 2.0 mm thickness

35

-

-

... More
4.2.2 Supplying and installing following size of perforated pre-painted M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness

36

-

-

... More
4.2.4 Supplying and installing following size of perforated pre-painted M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness

40

-

-

... More
4.2.6 Supplying and installing following size of perforated pre-painted M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.450 mm width X 50 mm depth X 2.0 mm thickness

4

-

-

... More
4.2.7 Supplying and installing following size of perforated pre-painted M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.600 mm width X 50 mm depth X 2.0 mm thickness

8

-

-

... More
4.4.2 Supplying and installing following size of perforated pre-painted M.S. cable trays Tee's with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness

12

-

-

... More
4.4.4 Supplying and installing following size of perforated pre-painted M.S. cable trays Tee's with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness

12

-

-

... More
4.4.6 Supplying and installing following size of perforated pre-painted M.S. cable trays Tee's with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.450 mm width X 50 mm depth X 2.0 mm thickness

1

-

-

... More
4.4.7 Supplying and installing following size of perforated pre-painted M.S. cable trays Tee's with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.600 mm width X 50 mm depth X 2.0 mm thickness

1

-

-

... More
4.5.2 Supplying and installing following size of perforated pre-painted M.S. cable trays cross members with perforation not more than 17.5%, joined with connectors,suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness

14

-

-

... More
4.5.4 Supplying and installing following size of perforated pre-painted M.S. cable trays cross members with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness

12

-

-

... More
DWC HDPE PIPE

-

-

-

... More
90.12.10.5 Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation90/75 mm or nearest size

40

-

-

... More
Safety equipment

-

-

-

... More
OD54864/2024-2025 Providing and fixing of Insulating Elastomeric (a generic term that includes rubbers,latex and elastomeric compounds that may be natural or synthetic or a mixture or a combination of both) mat with ISI mark 1 mtr wide and 2mm thick to withstand 1.1 KV dielectric strength as per IS 15652-2006. (Make: Electromat, Safevolt)

6

-

-

... More
OD54890/2024-2025 First Aid Box as approved by St. John. Ambulance Brigade/Indian Red Cross conforming to IS 2217-1963.

1

-

-

... More
OD54892/2024-2025 Supply & fixing shock treatment chart duly mounted on a wooden frame with 5mm thick glass as required. (approximate front area 1.20sq.metre) in English,Hindi &Malyalam.

1

-

-

... More
OD54893/2024-2025 Providing & fixing danger plates made of mild steel at least 2mm thick & vitreous enameled white on both sides & with inscriptions in signal red colour on front side as required. Medium Voltage -size 200mm x150mm

2

-

-

... More
OD54895/2024-2025 Providing and fixing Dry Chemical Powder (DCP) type fire extinguishers confirming to IS 2878 -1976 and cylinders fully charged of following capacity. 4.5 KG

2

-

-

... More
OD54896/2024-2025 Providing of set of 4 Nos. 9.5Litre capacity GI bucket painted in post office red colour with prior coat of red oxide paint and written with white paint FIRE and mounted on MS angle iron frame with bracket of appropriate size & capacity I/c filling sand etc.

2

-

-

... More
Earthing

-

-

-

... More
5.6 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

4

-

-

... More
5.4 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

5

-

-

... More
5.14 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.

320

-

-

... More
5.19 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.

630

-

-

... More
Feeder pillar

-

-

-

... More
OD56541/2024-2025 Supply, installation, testing and commissioning of Feeder pillar 415V, 3- phase, 50 Hz, totally enclosed, free standing, dust, damp, vermin proof, hinged, lockable, double door on both side with 70 cm long legs, out door type Feeder Pillar with IP:55 protection made out of 2 mm thick MS sheet complete with Bus Bars, M.V. danger notice plate, voltmeter, voltmeter selector switch, indicating lamps, with suitable capacity aluminium leads/solid aluminium strips/rods, connections of incoming and outgoing cables by thimble, base frame of 50x50x6 MS angle iron,with canopy on top, complete as required and having following incoming and outgoing feeders separately housed in 16 SWG sheet steel enclosure contactors, timers, HRC switch fuse unit complete as per specifications and as required and with a separate MCCB as bypass arrangement. Incomer : 63 A 4P MCCB, 25KA-2 No (including bypass), 63 A 4P Contractor-1 No , Outgoing : 25A 4P MCB, 10KA- 8No. , The DB shall be provided with 24 hour cyclic astronomical timer equipment along with control lead to be mounted within the panel. The timer shall be capable of energizing 63A 4P contactor, 415V AC rating, with 1 No.63A 4P MCCB, 25 KA bypass arrangement.

1

-

-

... More
External Lightning

-

-

-

... More
90.15.3.3 Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70 mm top diameter, 130 mm bottom diameter thickness 3mm base plate dimensions of 200x200x12 mm suitable for wind speed as per IS 875 Part III single arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc. complete 6 Meters

8

-

-

... More
11.3.1 Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.Above 4.5 metre and upto 6.5 metre

8

-

-

... More
90.15.4.3 Supply Conveyance, installation, testing and commissioning of 70W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)

8

-

-

... More
90.16.1.11 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.06 mm GI conductor (8 SWG)

400

-

-

... More
Mild Steel Fabricated structures

-

-

-

... More
OD56583/2024-2025 Supplying and erection of structural steel with painted MS angles/flats of required sizes in the trenches, on roof etc., The angles/channels shall be welded/grounded in the trench/walls/truss structure. The rate shall include grounding, welding and fixing complete.

1000

-

-

... More
DG ( Diesel Generator)

-

-

-

... More
OD54804/2024-2025 Supply, Installation, testing and commissioning of radiator cooled 3 phase, 415V, 0.8pf 50hz. DG set of the rating 160 kVA comprising of diesel engine, alternator, fuel tank, starting system, battery, battery charger, electronic governor etc with all accessories required for automatic ON/OFF of DG using AMF (installed separately not in this scope). The battery charger shall be included by the same manufacturer of auxiliary DC power supply unit, with dry batteries with connecting leads and terminals with stationary type, high discharge perfomance, Valve Regulated Lead Acid (VRLA) sealed maintenance free, battery charger including all other accessories. The Generator set shall have a integral type acoustic enclosure as per latest latest CPCB norms with standard control panel inside enclosure with 315A MCCB with protection releases as per Kerala State - KSEI & KSEB norms, digital voltmeter and ammeter, indication lamps and all other accessories, protection releases, over and under voltage and current trip, emergency push button complete as required. Energy meter & CTs shall be tested and certificate shall be provided.

1

-

-

... More
Electrical Substation

-

-

-

... More
OD54725/2024-2025 Supply,installaton,testing and commissioning of 11kKV 630A, 21kA SF6 Insulated Outdoor Motorized Extensible 1 Way Consisting Of 12 VCB RMU Type SABRA - VCE for coupling with existing RMU

1

-

-

... More
OD54749/2024-2025 Supply, installation, testing and commissioning of 200 KVA Indoor Unitized Sub Station 200 KVA Resin Cast Indoor Distribution Transformer Ratio 11KV/433V, 3 Ph., AN cooled, with WTI, Vector Dyn-11 with off circuit tapping from +5% to -10% in steps of 2.5%, changeable by tap links provided, with LV cable box and HV terminals connected to HT Panel 1. 11KV 630A 26.3KA Load Break Switch 2. HT HRC Fuse, Seal off Bushing 3. Al bus Bar, Support Insulators, wiring ,earthing etc. 4. CT : 3 Nos, Ratio :**/5 A, Class 0.2S, 10 VA 5. PT11KV/110V, 25VA, Class:0.2 : 1 No. 6. Provision for TOD Meter

1

-

-

... More
OD54800/2024-2025 Supply 11 KV power cable of following size, Stranded, compact circular aluminium conductor, conductor screened with extruded semiconductor compound, XLPE insulated, insulation screened with extruded semiconductor compund in combination with copper tape, cores laid up, inner sheathed with PVC, galvanised steel flat strip armoured overall PVC sheathed, cable confirming to IS: 7098- Part- I I - 1985 with latest amendments. 3C x 150 sq.mm

120

-

-

... More
8.1.2 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 120 sq. mm and upto 400 sq. mm

100

-

-

... More
8.4.2 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing masonry open duct as required.Above 120 sq. mm and upto 400 sq. mm

20

-

-

... More
Network

-

-

-

... More
OD54703/2024-2025 Supply and Installation of Wall Mount 9U Network Rack x 550 W x 450 D , Front Glass ,Door with Lock, 2 pairs of 19" Mounting Rails :- Standard Accessories : - 1U Cable Manager, Roof Mounted Fan Unit / 90 CFM /230V AC, 6 Way 5 Amp Power Distribution Unit, Mounting Hardware

8

-

-

... More
OD54708/2024-2025 Supply and Installation of network switch 48 x 10/100/1000BASE-T PoE ports ,4 x Gigabit RJ45/SFP Combo ports,Advanced L2 switching and security features L2+ Static Routing Optional “standard mode” or “surveillance mode” management user interface. Power over Ethernet: Class 4 PoE on 24 ports | PoE power budget 370 Watts.

4

-

-

... More
OD54698/2024-2025 Supply, Installation, Testing and Commissioning of L2+ 24 port 10/100/1000Mbps PoE+ Switch meets IEEE standards 802.3, 802.3u, 802.3ab, 802.3x, 802.1Q, 802.1p, 802.1D and 802.1ad , PoE Power budget 190 Watts or above, with 48 Gbps throughput in full duplex mode having port based VLAN with 2 or more SFP uplink ports, rack mountable switch with minimum 3 years onsite warranty.<br>Approved Make HP, Netgear. Ruckus, Brocade,juniper,Cisco or equivalent

2

-

-

... More
OD54710/2024-2025 Supply and Installation of 48 Port Fully Loaded Patch Panel with RJ 45 Keystones confirming TIA / EIA 568 standards

4

-

-

... More
OD54724/2024-2025 Supply and Installation of Cat6 UTP 24AWG factory crimped PATCH CHORD made out of 300 Mhz Unshielded twisted pair confirming TIA / EIA 568 Category 6 Cabling System with Reference Standards - UL Subject 444, EIAITIA-568 B.2.1, ISO/IEC 11801 & IEC61156 of 2 Meter

400

-

-

... More
OD54697/2024-2025 Supply and fixing 24 port Enhanced CAT- 6 fully loaded Modular type Patch Panel as per EIA/TIA-TSB 40A specification for interconnecting Switch and Computers, including termination charges. Preferred Make: Actassi, Belden, Molex, R&M, Commscope or equivalent

2

-

-

-

-

-

... More
OD54690/2024-2025 Supply, Installation, Testing and Commissioning of 13 Passenger Lift , 884kgs , 1.25 m/s speed ,Machine room (Gearless) , Travel- 20 Mtr. (approx),Floors G + 4 , 05 Stops, 05 Openings, Shaft Size required: 2500 mm W X 1900 mm D, Car Size: 2000 mm W X 1100 mm D, Clear Door Opening: 900mm W X 2000mm H , Center Opening doors , V3F Microprocessor based AC Variable, Variable Freq. Full Collective Simplex Control , Vandal Proof Stainless steel Finish , Center Opening Power Operated sliding Car Door in SS Vandeal Proof Finish , Centre Opening Power Operated Landing Door in SS Vandeal Proof Finish , PVC Flooring , Automatic Rescue Device, Infra-Red Screen Sensor, , Floor Annunciator with music , Over Load Warning Indicator , False Ceiling in Car , Digital Floor Position Indicators In Car & Landings – Orange Colour , Push Button – Orange L E D Illumination , Full Car Operating Panel – Press & Speak , Sill Angle , Sill Support , Fireman’s Switch At Ground Floor , Battery Operated Alarm Bell and Emergency Light , Pit Ladder , Minor Builders Works , Scaffolding , Lift License , Free Service One Year.

2

-

-

... More
Air Conditioning Works

-

-

-

... More
OD56584/2024-2025 SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF CASSETTE TYPE VRF INDOOR UNITS. THE INDOOR UNIT SHALL BE OF THE FOURWAY CASSETTE TYPE INDOOR UNITS AS PER THE REQUIREMENTSSPECIFIED IN THE BOQ / DRAWINGS. ALL INDOORS HAVE ELECTRONIC EXPANSION VALVE THAT CONTROLS THE FLOW OF REFRIGERANT IN RESPOND TO THE LOAD VARIATIONS OF ROOM ACCORDING TO SET TEMPERATURE, WHICH CAN SET BY REMOTE CONTROLLERS. ALL INDOOR UNITS SHOULD HAVE INBUILT DRAIN PUMP WITH MINIMUM 700MM VERTICAL LIFT HEAD. ELECTRICITY CHARACTERISTICS FOR INDOOR UNIT SHALL BE 240 VOLTS/ 1PHASE / 50HZ- 4-WAY CASSETTE TYPE - 4TR

1

-

-

... More
OD56586/2024-2025 SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF MODULAR TYPE VRF ODU.THE OUTDOOR UNIT SHALL BE FACTORY ASSEMBLED, WEATHER PROOF CASING, CONSTRUCTED FROM HEAVY GAUGE MILD STEEL PANELS AND COATED WITH BAKED ENAMEL FINISH. THE UNIT SHOULD BE COMPLETELY FACTORY WIRED TESTED WITH ALL NECESSARY CONTROLS. OUTDOORS UNITS OF THE VRF/VRV SYSTEM SHALL BE COMPACT AIR COOLED TYPE.ALL THE COMPRESSORS OF THE OUTDOOR UNITS MUST BE HERMETICALLY SEALED BLDC INVERTER SCROLL/TWIN ROTARY TYPE. OEM SHOULD USE THERE ON MAKE COMPRESSORS IN VRF /VRV SYSTEM WHICH IS TO BE SUPPLIED. SYSTEM COP SHALL NOT BE LESS THAN – 3.7 AT AHRI CONDITION AND SUITABLE TO OPERATE AT HEAT LOAD PROPORTIONAL TO INDOOR TEMPERATURE REQUIREMENT. ALUMINUM FINS OF CONDENSER COIL SHALL HAVE ANTI CORROSIVE BLACK EPOXY RESIN OCEAN BLACK COATING ALONG WITH HYDROPHILIC COATING. PRE-COATED AT FACTORY. THE ANTI-CORROSIVE TREATMENT SHOULD HAVE BEEN TESTED FOR AT LEAST 2500HRS OF STANDARD SALT SPRAY TEST AND MUST HAVE A CERTIFIED LIFE OF MINIMUM 20 YEARS SUPPORTED BY CERTIFICATE FROM REPUTED INTERNATIONAL INSTITUTION IS MANDATORY. THE TREATMENT SHOULD BE SUITABLE FOR AREAS OF HIGH POLLUTION AND SALT LADEN AIR.MODULAR SUYTEM TO BE CONFIGURED AS PER MENTION MODULES GIVEN IN BRACKET- 16 HP

2

-

-

... More
OD56587/2024-2025 SUPPLY, INSTALLATION,TESTING AND COMMISSIONING OF 2 TR (3 MTR COPPER PIPE KIT INCLUDED) 5 STAR INVERTER SPLIT AC WITH 100% COPPER CONDENSER COIL, R32 REFRIGERANT GAS AND SINGLE-PHASE RATED POWER SUPPLY HAVING 1 YEAR WARRANTY ON MACHINE AND 5 YEARS ON COMPRESSOR. Make: BLUE STAR /DAIKIN/CARRIER

2

-

-

... More
OD56588/2024-2025 SUPPLY, TESTING AND COMMISSIONING OF CONDENSATE CONDENSATE DRAIN UPVC PIPING AS PER BIS 4985 WITH NECESSARY CLAMPS, SUPPORTS, HANGERS AND FITTING SUCH AS BEND, TEES, REDUCERS ETC COMPLETE AS PER SPECIFICATIONS AND AS REQUIRED., ALL COMPLETE AS PER DIRECTION OF ENGINEER-IN-CHARGE 32MM DIA UPVC

50

-

-

... More
OD56593/2024-2025 SUPPLY, TESTING AND COMMISSIONING OF CONDENSATE CONDENSATE DRAIN UPVC PIPING AS PER BIS 4985 WITH NECESSARY CLAMPS, SUPPORTS, HANGERS AND FITTING SUCH AS BEND, TEES, REDUCERS ETC COMPLETE AS PER SPECIFICATIONS AND AS REQUIRED ALL COMPLETE AS PER DIRECTION OF ENGINEER-IN-CHARGE 25MM DIA UPVC

60

-

-

... More
OD56590/2024-2025 SUPPLY,INSTALLATION,TESTING AND COMMISSIONING OF 3/8" SOFT DRAWN COPPER REFRIGERANT PIPING INCLUDING ALL ACCESSORIES FOR SPLIT AC

80

-

-

... More
OD56591/2024-2025 SUPPLY,INSTALLATION,TESTING AND COMMISSIONING OF 5/8" SOFT DRAWN COPPER REFRIGERANT PIPING INCLUDING ALL ACCESSORIES FOR SPLIT AC

20

-

-

... More
OD56592/2024-2025 SUPPPLY,INSTALLATION,TESTING AND COMMISSIONING OF HARD DRAWN COPPER REFRIGERANT PIPING INCLUDING ALL ACCESSORIES INCLUDING JOINTS PROPERLY BRAZED INSULATED WITH CHEMICALLY CROSSLINKED NITRILE RUBBER FIRE RETARDANT GRADE CLASS O WITH 13MM THICKNESS AND NECESSARY SUPPORTS AS REQUIRED OF SIZE 19.05MM

20

-

-

... More
OD56594/2024-2025 SUPPPLY,INSTALLATION,TESTING AND COMMISSIONING OF HARD DRAWN COPPER REFRIGERANT PIPING INCLUDING ALL ACCESSORIES INCLUDING JOINTS PROPERLY BRAZED INSULATED WITH CHEMICALLY CROSSLINKED NITRILE RUBBER FIRE RETARDANT GRADE CLASS O WITH 19MM THICKNESS AND NECESSARY SUPPORTS AS REQUIRED OF SIZE 15.9MM DIA

25

-

-

... More
OD56595/2024-2025 SUPPPLY,INSTALLATION,TESTING AND COMMISSIONING OF HARD DRAWN COPPER REFRIGERANT PIPING INCLUDING ALL ACCESSORIES INCLUDING JOINTS PROPERLY BRAZED INSULATED WITH CHEMICALLY CROSSLINKED NITRILE RUBBER FIRE RETARDANT GRADE CLASS O WITH 13MM THICKNESS AND NECESSARY SUPPORTS AS REQUIRED OF SIZE 12.7MM DIA

40

-

-

... More
OD56596/2024-2025 SUPPPLY,INSTALLATION,TESTING AND COMMISSIONING OF HARD DRAWN COPPER REFRIGERANT PIPING INCLUDING ALL ACCESSORIES INCLUDING JOINTS PROPERLY BRAZED INSULATED WITH CHEMICALLY CROSSLINKED NITRILE RUBBER FIRE RETARDANT GRADE CLASS O WITH 13MM THICKNESS AND NECESSARY SUPPORTS AS REQUIRED OF SIZE 9.52MM DIA

40

-

-

... More
16.12.1.1 Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006 Thickness 0.63 mm sheet

20

-

-

... More
16.12.1.2 Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006 Thickness 0.80 mm sheet

90

-

-

... More
OD56602/2024-2025 Supply, installation, testing and commissioning of 1.3 HP Hi-Wall Unit for VRF unit

1

-

-

... More
OD56604/2024-2025 Supply, installation, testing and commissioning of 2.5 HP Celling Concealed unit for VRF unit

4

-

-

... More
OD56605/2024-2025 Supply, installation, testing and commissioning of 4.0 HP Celling Concealed unit for VRF unit

2

-

-

... More
OD56606/2024-2025 Supply, installation, testing and commissioning of 5.0 HP Celling Concealed unit for VRF unit

1

-

-

... More
OD56607/2024-2025 Supply, installation, testing and commissioning of 6.0 HP Celling Concealed unit for VRF unit

2

-

-

... More
OD56610/2024-2025 Supply and installation of Multi kits for Indoor Units

10

-

-

... More
OD56611/2024-2025 Supply and installation of Central Controller - Touch Screen Type for AC unit

1

-

-

... More
OD56614/2024-2025 Supply and Installation of external thermal insulation on supply air duct 13 mm thick nitrile rubber class O closed cell type insulation

80

-

-

... More
OD56616/2024-2025 Supply and Installation of acoustic insulation on supply air duct lining using 10 mm nitrile rubber insulation

30

-

-

... More
OD56617/2024-2025 Supply and Installation of ADP : Linear Air Grille

4

-

-

... More
OD56618/2024-2025 Supply and Installation of ADP :Collar Damper for Linear Air Grille

4

-

-

... More
90.6.5.11 Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm

190

-

-

... More
90.6.5.12 Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm

40

-

-

... More
90.6.5.13 Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 4.00 sq mm

20

-

-

... More
OD56625/2024-2025 SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF ADDITIONAL REFRIGERANT GAS CHARGE R32 A (SPLIT UNIT)

15

-

-

... More
90.6.5.4 Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.2 core 1.50 sq mm

60

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.