Kerala Police Housing And Construction Corporation Limited Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Kerala Police Housing And Construction Corporation Limited - KPHCCL Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date1 Jan 2025
Closing Date8 Jan 2025
Tender Amount₹ 1,43,858
Costs
EMD
₹ 3,600Document Cost
₹ 590Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_KPHCC_722050_2Tender No
NIT No.180/KPHCC/2024-2025Tender Authority
Kerala Police Housing And Construction Corporation Limited ViewPurchaser Address
-Website
http://https://kphccltd.kerala.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
90.11.1.15: Supply and installation of sheet steel, phosphatised and painted, dust and vermin
proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus
and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable
anchor bolts or fixed in recess including cutting hole on the wall , making good the
damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical
DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/
TP MCB as outgoing (IP 42/43)
1
-
-
... More
2.3.3
Supplying and fixing following way, single pole and neutral, sheet steel, MCB
distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar,
neutral bus bar, earth bar, din bar, interconnections, powder painted including
earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
1
-
-
... More
2.10.1
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature
circuit breaker suitable for inductive load of following poles in the existing MCB DB
complete with connections, testing and commissioning etc. as required.Single pole
42
-
-
... More
2.10.4
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature
circuit breaker suitable for inductive load of following poles in the existing MCB DB
complete with connections, testing and commissioning etc. as required.Triple pole
4
-
-
... More
OD803/2024-2025
Supplying and fixing 63 amps rating, 240/415 volts, "C" curve, miniature
circuit breaker suitable for inductive load of following poles in the existing MCB DB
complete with connections, testing and commissioning etc. as required.
Triple pole
2
-
-
... More
2.11
Supplying and fixing single pole blanking plate in the existing MCB DB complete
etc. as required.
10
-
-
... More
2.12.1
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing
MCB DB complete with connections, testing and commissioning etc. as required.40
amps
1
-
-
... More
2.13.1
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing
MCB DB complete with connections, testing and commissioning etc. as required.40
amps
1
-
-
... More
2.13.2
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing
MCB DB complete with connections, testing and commissioning etc. as required.63
amps
1
-
-
... More
2.14.2
Supplying and fixing following rating, double pole, (single phase and neutral), 240
volts, residual
current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in
the existing MCB DB complete with connections, testing and commissioning etc. as
required.40 amps
1
-
-
... More
2.15.2
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts,
residual
current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as
required.40 amps
1
-
-
... More
2.15.3
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts,
residual
current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in
the existing MCB DB complete with connections, testing and commissioning etc. as
required.63 amps
1
-
-
... More
90.12.7.42
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured
aluminium power cable, 1.1 KV grade of the following sizes using clamps noted
along with the cables, spacing of clamps not exceeding 60cms, making good the
damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp
15
-
-
... More
9.1.34
Supplying and making end termination with brass compression gland and aluminium
lugs for
following size of PVC insulated and PVC sheathed / XLPE aluminium conductor
cable of 1.1 KV
grade as required.4 X 25 sq. mm (28mm)
2
-
-
... More
90.16.1.3
Supply and drawing bare earthing conductors of the following sizes along with
wiring/ cables and giving connection as required3.15 mm copper conductor ( 10
SWG)
70
-
-
... More
90.16.5.3
Supply of superior quality copper earth socket for the following size of earth
conductor including crimping etc. as required.3.15 mm (10 SWG)
16
-
-
... More
5.4
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including
accessories, and providing masonry enclosure with cover plate having locking
arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as
required.
2
-
-
... More
1.14.9
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of
FRLS PVC insulated copper conductor, single core cable in surface / recessed
medium class PVC conduit as required4 X 6 sq. mm + 2 X 6 sq. mm earth wire
30
-
-
... More
1.7.10
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of
FRLS PVC
insulated copper conductor, single core cable in surface/ recessed steel conduit as
required4 X 10 sq. mm + 2 X 6 sq. mm earth wire
15
-
-
... More
1.17.3
Supplying and drawing following sizes of FRLS PVC insulated copper conductor,
single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X
1.5 sq.mm
60
-
-
... More
1.17.12
Supplying and drawing following sizes of FRLS PVC insulated copper conductor,
single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x
2.5 sq. mm
90
-
-
... More
1.17.20
Supplying and drawing following sizes of FRLS PVC insulated copper conductor,
single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x
4 sq. mm
40
-
-
... More
1.21.1
Supplying and fixing of following sizes of medium class PVC conduit along with
accessories in surface/ recess including cutting the wall and making good the same in
case of recessed conduit as required.20 mm
120
-
-
... More
1.21.2
Supplying and fixing of following sizes of medium class PVC conduit along with
accessories in surface/ recess including cutting the wall and making good the same in
case of recessed conduit as required.25 mm
60
-
-
... More
OD804/2024-2025
Fabrication, supply & installation of dust and vermin proof, wall mounting, three
phase Meter Box of suitable for fixing KSEB meter,fuse units, CT etc, hinged door
construction for the front side with compartments if necessary, providing vision panel
for the meter compartment, knock out for cable entry and exit with the following.
63A,415V Fuse- 3 Nos, 63A ,415V ,Neutral Link- 1 No,63A TPN SFU- 1No, 63A
HRC Link - 1 No
1
-
-