Kerala Police Housing And Construction Corporation Limited Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 16,500Document Cost
₹ 1,593Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_KPHCC_710877_1Bid Award Id
ViewTender No
NIT No.161/KPHCC/2024-25Tender Authority
Kerala Police Housing And Construction Corporation Limited ViewPurchaser Address
-Website
http://https://kphccltd.kerala.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
60.7.1
DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry
with good quality blasted rubble including packing to compactness to lines and levels
cost and conveyance of all materials labour charges etc. complete as per direction of
Departmental officers at site
8
-
-
... More
7.1.1
Random rubble masonry with hard stone in foundation and plinth including levelling
up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate
20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse
sand)
3
-
-
... More
4.1.8
Providing and laying in position cement concrete of specified grade excluding the
cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4
coarse sand : 8 graded stone aggregate 40 nominal size)
3
-
-
... More
5.1.2
Providing and laying in position specified grade of reinforced cement concrete,
excluding the cost of centering, shuttering, finishing and reinforcement - All work up
to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm
nominal size
2
-
-
... More
5.3
Reinforced cement concrete work in beams, suspended floors, roofs, having slope up
to 15sup0/sup landings, balconies, shelves, chajjas, lintels, bands, plain window
sills, staircases and spiral stair cases up to floor five level excluding the cost of
centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse
sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
5
-
-
... More
5.9.5
Centering and shuttering including strutting, etc. and removal of form for:Lintels,
beams, plinth beams, girders bressumers and cantilevers
13
-
-
... More
5.9.3
Centering and shuttering including strutting, etc. and removal of form for:Suspended
floors, roofs, landings, balconies and access platform
41
-
-
... More
5.9.16.1
Centering and shuttering including strutting, etc. and removal of form for:
Edges of slabs and breaks in floors and wallsUnder 20 cm wide
26
-
-
... More
5.22.6
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing
in position and binding all complete upto plinth levelThermo - Mechanically Treated
bars of grade Fe-500D or more
735
-
-
... More
2.25
Filling available excavated earth (excluding rock) in trenches, plinth, sides of
foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited
layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
10
-
-
... More
50.6.2.2
Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or
nearest available size confirming to IS 2185 part I of 1979 for super structure up to
floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc
complete
14
-
-
... More
13.1.1
12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
200
-
-
... More
13.16.1
6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
45
-
-
... More
13.9.1
Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat
cement.12 mm cement plaster
40
-
-
... More
OD30535/2024-2025
Providing and laying Vitrified floor tiles floor tiles of size 600x600 mm (thickness to
be specified by the manufacturer), of 1st quality conforming to IS : 15622, of
approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20
mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), For epoxy pointing, provide
3mm width gaps between tiles etc., complete.
25
-
-
... More
11.48.2
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout
mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg
of resin per kg). including filling /grouting and finishing complete as per direction of
Engineer-in-charge.Size of Tile 600x600 mm
25
-
-
... More
21.1.1.2
Providing and fixing aluminium work for doors, windows, ventilators and partitions
with extruded built up standard tubular sections/ appropriate Z sections and other
sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash
fasteners of required dia and size, including necessary filling up the gaps at junctions,
i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc.
Aluminium sections shall be smooth, rust free, straight, mitred and jointed
mechanically wherever required including cleat angle, Aluminnium snap beading for
glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural
drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash
fasteners to be paid for separately):
For fixed portionPowder coated aluminium (minimum thickness of powder coating
50 micron)
24
-
-
... More
21.1.2.2
For shutters of doors, windows & ventilators including providing and fixing hinges /
pivots and making provision for fixing of fittings wherever required including the
cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for
separately)Powder coated aluminium (minimum thickness of powder coating 50
micron)
75
-
-
... More
21.3.1
Providing and fixing glazing in aluminium door, window, ventilator shutters and
partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the
architectural drawings and the directions of Engineer - in -Charge. ( Cost of
aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm
thickness
7
-
-
... More
OD30552/2024-2025
Providing and fixing 3 mm Aluminium Composite Panel (ACP) board in panelling
fixed in aluminum doors, windows shutters, partition frames and shelf sections etc
with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.
1
-
-
... More
21.13
Providing and fixing 100 mm brass locks ( best make of approved quality ) for
aluminium doors including necessary cutting and making good etc. complete
1
-
-
... More
9.97.3
Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not
less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade,
with necessary screws complete:200x10 mm
2
-
-
... More
9.100.1
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not
less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or
shade, with necessary screws etc. complete:125 mm
2
-
-
... More
9.48.1
Providing and fixing M.S. Grills of required pattern in frames of windows etc. with
M.S. flats, square or round bars etc. including priming coat with approved steel
primer all complete.Fixed to steel windows by welding
100
-
-
... More
13.52.1
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied
as per manufacturer's specifications including appropriate priming coat,
preparation of surface, etc. complete.On steel work
5
-
-
... More
13.80
Providing and applying white cement based putty of average thickness 1 mm, of
approved brand and manufacturer, over the plastered wall surface to prepare the
surface even and smooth complete.
7.8
-
-
... More
13.48.1
Finishing with Deluxe Multi surface paint system for interiors and exteriors using
primer as per manufacturers specifications:Two or more coats applied on walls @
1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10
sqm
200
-
-
... More
ELECTRICAL WORKS
-
-
-
... More
1.10.1
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC
conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5
sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group A
2
-
-
... More
1.10.2
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm
FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC
conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5
sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group B
3
-
-
... More
1.10.3
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm
FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC
conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5
sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group C
2
-
-
... More
1.17.3
Supplying and drawing following sizes of FRLS PVC insulated copper conductor,
single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X
1.5 sq.mm
15
-
-
... More
1.17.12
Supplying and drawing following sizes of FRLS PVC insulated copper conductor,
single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x
2.5 sq. mm
15
-
-
... More
1.21.1
Supplying and fixing of following sizes of medium class PVC conduit along with
accessories in surface/ recess including cutting the wall and making good the same in
case of recessed conduit as required.20 mm
20
-
-
... More
1.31
Supplying and fixing suitable size GI box with modular plate and cover in front on
surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket
outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be
used in non residential buildings).
1
-
-
... More
1.32
Supplying and fixing suitable size GI box with modular plate and cover in front on
surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular
socket outlet and 15/16 amps modular switch, connection etc. as required.
1
-
-
... More
1.58
Supplying and fixing PVC batten/ angle holder including connection etc. as required.
1
-
-
... More
OD30530/2024-2025
Supply and fixing 9W LED bulb giving connections etc as required.
1
-
-
... More
1.33
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden
block including connection etc as required.
5
-
-
... More
1.25
Supplying and fixing two module stepped type electronic fan regulator on the existing
modular plate switch box including connections but excluding modular plate etc. as
required.
1
-
-
... More
OD30532/2024-2025
Supply, Installation, Testing and Commissioning of 20W LED Tube light fitting with
necessary accessories as required
3
-
-
... More
90.4.1
Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per
IS 732 as required.
1
-
-
... More
90.4.5.4
Supply, Installation, testing and commissioning of ceiling fan of following sizes
including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm
FRLS PVC insulated, copper conductor, single core cable etc. as required.
1200mm sweep - ceiling fan complete with service value minimum 4.0(cub
meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding
suitable for 230V/240V single phase AC supply
1
-
-
... More
90.16.1.1
Supply and drawing bare earthing conductors of the following sizes along with
wiring/ cables and giving connection as required2.00 mm copper conductor ( 14
SWG)
15
-
-
... More
90.16.5.1
Supply of superior quality copper earth socket for the following size of earth
conductor including crimping etc. as required.2.00 mm (14 SWG)
2
-
-
... More
OD30696/2024-2025
Supply and fixing outdoor LED light fittings like bulkhead model make philips/ govt
approved reputed brand and giving connections etc
1
-
-
Evaluation Notes How It Works ?
Potential Partner