Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 7,400Document Cost
₹ 708Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_KPHCC_720982_1Tender No
NIT No. 175/KPHCC/2024-25Tender Authority
Kerala Police Housing And Construction Corporation Limited ViewPurchaser Address
-Website
http://https://kphccltd.kerala.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
15.7.4.Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar
2.06
-
-
... More
4.1.8.Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
2.19
-
-
... More
7.1.1.Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
1.9
-
-
... More
50.6.2.2.Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete
3.3
-
-
... More
21.1.1.3.Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions,
i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):
For fixed portionPolyester powder coated aluminium ( minimum thickness of polyester powder coating 50 micron )
24.6
-
-
... More
21.1.2.2.For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)
20.4
-
-
... More
21.2.1.Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side
0.9
-
-
... More
21.3.1.Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness
3.46
-
-
... More
5.2.2.Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
0.28
-
-
... More
5.3.Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).15<sup>0</sup> landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering,shuttering,finishing and reinforcement with 1:1.5:3(1cement:1.5coarse sand(Zone III):3graded stone aggregate 20mm nominal size)
0.17
-
-
... More
5.9.5.Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
4.44
-
-
... More
5.22.6.Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
35.6
-
-
... More
9.48.1.Providing and fixing M.S. Grills of required pattern in frames of windows etc. with
M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding
54
-
-
... More
13.4.1.12 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand)
55.86
-
-
... More
13.48.1.Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @
1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm
55.86
-
-
... More
OD24785/2024-2025. Finishing walls with Premium Acrylic Smooth interior paint with Silicone additives of required shade:
Old work ( Two or more coats applied @ 1.43 ltr/10 sqm) over existing cement paint surface
46
-
-
... More
11.40.Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer) of Ist quality conforming to IS: 15622 of approved make in all colours, shades, except white, Ivory, Grey Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigments etc., complete.
28.54
-
-
... More
10.16.1.Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
115.02
-
-
... More
12.50.Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
23.79
-
-
... More
OD24785/2024-2025.Supplying and fixing of Table tops made of 25mm thick edge banded & prelaminated particle board with 18mm thick edge banded verticals. Top & bottom tile: Laminated board., Knock down fitting, Modestry panel, level adjustor, Visible edges are lipped with 2mm PVC edge band and other egde with .5mm edge band ,One Drawer unit , One cupboard unit and side almarah unit ( 60x45x135mm size) ,Keyboard tray ABS ket board tray mounted on sliders, CPU Stand _ Powder coated CPU stand on castors incluing Hardware like handle, lock & Key, minifix, podwer coated chipboard screws, pvc right angle block, SS support, level adjusters etc. are provided wherever required. etc modular partitions dividers between adjacent linear work stations 75mm width 80 microns powder coated CRCA partitions with pre punched cutouts to run electric & networking cables. Duel Race ways with punch out to fix electrical and data modules for power & data at skirting level & just below table top, writing board(White Board), pin up board(Soft Board). Partitons are covered with 9mm tiles(prelaminated particle board/MDF/Fabric Cladded Board) as required by using sliding panel method,Level adjusters and all the visible edges are covered with curved Aluminum trims. all cost and conveyance of all materials & labour charges etc complete MR
1
-
-
... More
Electrical works
-
-
-
... More
1.10.1.Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group A
3
-
-
... More
1.10.2.Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group B
4
-
-
... More
1.17.3.Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X
1.5 sq.mm
30
-
-
... More
1.17.12.Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x
2.5 sq. mm
35
-
-
... More
1.21.1.Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
40
-
-
... More
1.21.2.Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
20
-
-
... More
1.24.1.Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
10
-
-
... More
1.27.1.Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
3
-
-
... More
1.24.4.Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
8
-
-
... More
1.25.Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
3
-
-
... More
1.27.2.Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
2
-
-
... More
1.27.4.Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
6
-
-
... More
1.33.Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
10
-
-
... More
90.4.8.Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.
1
-
-
... More
1.53.1.Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable
50
-
-
... More
1.58.Supplying and fixing PVC batten/ angle holder including connection etc. as required.
2
-
-
... More
2.10.1.Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2
-
-
... More
OD25160/2024-25.supply and fixing of 400mm sweep wall fan with all accessories and giving proper connections as required. make crompton or equivalent
1
-
-
... More
OD25194/2024-25Supply and fixing of 8 inch PVC Exhaust fan including all accessories, working on 230 V A/C. make Havells or equivalent
1
-
-
... More
OD25161/2024-2025.Supply and fixing 9 W LED Bulb make philips/Govt approved reputed brand .
2
-
-
... More
OD25162/2024-2025labour for wireman
2
-
-
... More
OD25162/2024-2025.Supply and fixing of 20W 4feet led tube light . LUKER or equivalent make,giving connections etc complete as required.
4
-
-
... More
90.4.5.4.Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
2
-
-
... More
90.4.1.Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
3
-
-
... More
OD25162/2024-2025.Supply and fixing of CAT6 I/O socket in the existing suitable modular plate and suitable gi box ,giving proper connection as required
2
-
-
Evaluation Notes How It Works ?