Kerala Police Housing And Construction Corporation Limited Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 15,700Document Cost
₹ 1,534Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_KPHCC_652526_1Bid Award Id
ViewTender No
NIT NO. 215/KPHCC/2023-24Tender Authority
Kerala Police Housing And Construction Corporation Limited ViewPurchaser Address
-Website
http://https://kphccltd.kerala.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
5.1.2
Providing and laying in position specified grade of reinforced cement concrete,
excluding the cost of centering, shuttering, finishing and reinforcement - All work up
to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm
nominal size
5.24
-
-
5.2.2
Reinforced cement concrete work in walls (any thickness), including attached
pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,
abutments, posts and struts etc. up tot floor five level excluding cost of centering,
shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded
stone aggregate 20 mm nominal size)
1.1
-
-
5.3
Reinforced cement concrete work in beams, suspended floors, roofs, having slope up
to 15sup0/sup landings, balconies, shelves, chajjas, lintels, bands, plain window
sills, staircases and spiral stair cases up to floor five level excluding the cost of
centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse
sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
5.31
-
-
5.9.1
Centering and shuttering including strutting, etc. and removal of form
for:Foundations, footings, bases of columns, etc for mass concrete
30.28
-
-
5.9.3
Centering and shuttering including strutting, etc. and removal of form for:Suspended
floors, roofs, landings, balconies and access platform
27.6
-
-
5.9.5
Centering and shuttering including strutting, etc. and removal of form for:Lintels,
beams, plinth beams, girders bressumers and cantilevers
16
-
-
5.9.6
Centering and shuttering including strutting, etc. and removal of form for:Columns,
Pillars, Piers, Abutments, Posts and Struts
15.12
-
-
5.9.19
Centering and shuttering including strutting, etc. and removal of form for:Weather
shade, Chajjas, corbels etc., including edges
5.16
-
-
2.25
Filling available excavated earth (excluding rock) in trenches, plinth, sides of
foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited
layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
15
-
-
50.2.25.1
Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of
foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited
layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction
of site Engineer-in-charge
9.2
-
-
5.22A.6
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing
in position and binding all complete above plinth level.Thermo - Mechanically
Treated bars of grade Fe-500D or more
1073.16
-
-
13.1.1
12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
104.29
-
-
13.16.1
6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
29.16
-
-
9.1.1
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash
fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for
separately).Second class teak wood
0.08
-
-
9.5.1.1
Providing and fixing panelled or panelled and glazed shutters for shutters for doors,
windows and clerestory windows, including ISI marked M.S. pressed butt hinges
bright finished of required size with necessery screws, excluding panelling which will
be paid for separately, all complete as per direction of Engineer - in-charge.
Second class teak wood35 mm thick shutters
2.31
-
-
21.1.1.2
Providing and fixing aluminium work for doors, windows, ventilators and partitions
with extruded built up standard tubular sections/ appropriate Z sections and other
sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash
fasteners of required dia and size, including necessary filling up the gaps at junctions,
i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc.
Aluminium sections shall be smooth, rust free, straight, mitred and jointed
mechanically wherever required including cleat angle, Aluminnium snap beading for
glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural
drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash
fasteners to be paid for separately):
For fixed portionPowder coated aluminium (minimum thickness of powder coating
50 micron)
24
-
-
21.1.2.2
For shutters of doors, windows & ventilators including providing and fixing hinges /
pivots and making provision for fixing of fittings wherever required including the
cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for
separately)Powder coated aluminium (minimum thickness of powder coating 50
micron)
24
-
-
21.3.1
Providing and fixing glazing in aluminium door, window, ventilator shutters and
partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the
architectural drawings and the directions of Engineer - in -Charge. ( Cost of
aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm
thickness
6.75
-
-
9.63.2
Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type)
with necessary screws etc. complete:200x10 mm
1
-
-
9.63.3 Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type)
with necessary screws etc. complete:150x10 mm
1
-
-
9.70.1
Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel
screws etc. complete:125x64x1.90 mm
4
-
-
9.76
Providing and fixing bright finished brass 100 mm mortice latch and lock with 6
levers and a pair of lever handles of approved quality with necessary screws etc.
complete.
1
-
-
9.121
Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of crosssection 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of
30 mm thickness. The laminated shall be moulded with fire resistant grade
unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm
thick and shall be filled with suitable wooden block in all the three legs. The frame
shall be covered with fiber glass from all sides. M.S. stay shall be provided at the
bottom to steady the frame.
5.1
-
-
9.122.1
Providing and fixing to existing door frames.30 mm thick Glas Fibre Reinforced
Plastic (FRP) panelled door shutter of required colour and approved brand and
manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to
3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and
suitable blocks of seasoned wood inside at required places for fixing of fittings, cast
monolithically with 5 mm thick FRP laminate for panels conforming to IS : 14856,
including fixing to frames.
1.89
-
-
9.165.1
Providing and fixing bright /matt finished Stainless Steel handles of approved
quality & make with necessary screws etc all complete.125 mm
2
-
-
13.48.1
Finishing with Deluxe Multi surface paint system for interiors and exteriors using
primer as per manufacturers specifications:Two or more coats applied on walls @
1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10
sqm
147.84
-
-
13.61.1
Painting with synthetic enamel paint of approved brand and manufacture to give an
even shade:Two or more coats on new work
5.06
-
-
50.6.2.2
Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or
nearest available size confirming to IS 2185 part I of 1979 for super structure up to
floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc
complete
11.11
-
-
11.41.2
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by
the manufacturer) with water absorption less than 0.08% and conforming to IS :
15622, of approved make, in all colours and shades, laid on 20 mm thick cement
mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement
and matching pigments etc., complete.Size of Tile 600 x 600 mm.
24
-
-
11.48.2
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout
mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg
of resin per kg). including filling /grouting and finishing complete as per direction of
Engineer-in-charge.Size of Tile 600x600 mm
24
-
-
13.69.1
Polishing on wood work with ready mixed wax polish of approved brand and
manufacture:New work
5.2
-
-
ELECTRICAL WORKS
-
-
-
1.10.1
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm
FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC
conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5
sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group A
1
-
-
1.10.2
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm
FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC
conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5
sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group B
1
-
-
1.10.3
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm
FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC
conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5
sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group C
1
-
-
1.11
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper
conductor single core cable in surface / recessed medium class PVC conduit, 2 way
modular switch, modular plate, suitable GI box and earthing the point with 1.5
sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
1
-
-
1.17.1
Supplying and drawing following sizes of FRLS PVC insulated copper conductor,
single core cable in the existing surface / recessed steel/ PVC conduit as required.1 x
1.5 sq. mm
25
-
-
1.17.3
Supplying and drawing following sizes of FRLS PVC insulated copper conductor,
single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X
1.5 sq.mm
15
-
-
1.17.12
Supplying and drawing following sizes of FRLS PVC insulated copper conductor,
single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x
2.5 sq. mm
45
-
-
1.17.21
Supplying and drawing following sizes of FRLS PVC insulated copper conductor,
single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x
4 sq. mm
5
-
-
1.17.30
Supplying and drawing following sizes of FRLS PVC insulated copper conductor,
single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x
6 sq. mm
5
-
-
1.21.1 Supplying and fixing of following sizes of medium class PVC conduit along with
accessories in surface/ recess including cutting the wall and making good the same in
case of recessed conduit as required.20 mm
25
-
-
1.21.2
Supplying and fixing of following sizes of medium class PVC conduit along with
accessories in surface/ recess including cutting the wall and making good the same in
case of recessed conduit as required.25 mm
15
-
-
1.25
Supplying and fixing two module stepped type electronic fan regulator on the existing
modular plate switch box including connections but excluding modular plate etc. as
required.
1
-
-
1.27.1
Supplying and fixing following size/ modules, GI box alongwith modular base &
cover plate for modular switches in recess etc as required.1 or 2 Module
(75mmX75mm)
3
-
-
1.31
Supplying and fixing suitable size GI box with modular plate and cover in front on
surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket
outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be
used in non residential buildings).
3
-
-
1.32
Supplying and fixing suitable size GI box with modular plate and cover in front on
surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps
modular socket outlet and 15/16 amps modular switch, connection etc. as required.
1
-
-
1.33
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden
block including connection etc as required.
8
-
-
1.56
Supplying and fixing suitable size Gl box with modular plate and cover in front on
surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket
outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light
plugs to be used in non residential buildings).
2
-
-
1.58
Supplying and fixing PVC batten/ angle holder including connection etc. as required.
2
-
-
2.3.3
Supplying and fixing following way, single pole and neutral, sheet steel, MCB
distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar,
neutral bus bar, earth bar, din bar, interconnections, powder painted including
earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
1
-
-
2.10.1
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve,
miniature circuit breaker suitable for inductive load of following poles in the existing
MCB DB complete with connections, testing and commissioning etc. as
required.Single pole
5
-
-
2.11
Supplying and fixing single pole blanking plate in the existing MCB DB complete
etc. as required.
5
-
-
2.12.1
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing
MCB DB complete with connections, testing and commissioning etc. as required.40
amps
1
-
-
2.14.2
Supplying and fixing following rating, double pole, (single phase and neutral), 240
volts, residual
current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in
the existing MCB DB complete with connections, testing and commissioning etc. as
required.40 amps
1
-
-
2.16
Supplying and fixing DP sheet steel enclosure on surface/ recess along with
25/32amps 240 volts "C" curve DP MCB complete with connections,
testing and commissioning etc. as required
1
-
-
90.4.1
Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per
IS 732 as required.
2
-
-
90.10.3.15
Supply and Fixing the following modular switches & accessories in the existing
front plates and giving necessary connections as required (RoHS compliant )32A DP
switch with indicator
1
-
-
90.10.3.33
Supply and Fixing the following modular switches & accessories in the existing
front plates and giving necessary connections as required (RoHS compliant )25A 3pin
Shuttered socket
1
-
-
90.16.1.3
Supply and drawing bare earthing conductors of the following sizes along with
wiring/ cables and giving connection as required3.15 mm copper conductor ( 10
SWG)
5
-
-
90.4.5.4
Supply, Installation, testing and commissioning of ceiling fan of following sizes
including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm
FRLS PVC insulated, copper conductor, single core cable etc. as required.
1200mm sweep - ceiling fan complete with service value minimum 4.0(cub
meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding
suitable for 230V/240V single phase AC supply
1
-
-
90.12.7.40
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured
aluminium power cable, 1.1 KV grade of the following sizes using clamps noted
along with the cables, spacing of clamps not exceeding 60cms, making good the
damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
15
-
-
OD16456/2023-2024
Supply installation testing and commissioning of 4feet 20W led battan with 2000
Lumens ,25000 burning hours, and all accessories electrical connections as required.
make-philips/wipro/havells or equivalent
3
-
-
OD11222/2023-2024
Labour for wireman
1
-
-
OD11226/2023-2024
Supply installation testing and commissioning of 2feet 10W led batten with 1000
Lumens ,25000 burning hours,all accessories ,electrical connections.including fixing
materials required. make-philips/wipro/havells or equivalent
2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements