Kerala Medical Services Corporation Limited Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Kerala Medical Services Corporation Limited - KMSCL Tender
Transportation and Logistics
Machinery and Tools
Eprocure
Opening Date25 Nov 2023
Closing DateCancelled
Tender Amount₹ 1,58,10,000
Costs
EMD
₹ 4,74,300Document Cost
₹ 29,500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_KMSCL_620127_6Tender No
KMSCL/EP/515/2023Tender Authority
Kerala Medical Services Corporation Limited ViewPurchaser Address
-Website
http://https://etenders.kerala.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Ultrasonic Cleaner
3
-
-
... More
Table Top Sterilizer
2
-
-
... More
Drying Cabinet
1
-
-
... More
Sealing Machine
3
-
-
... More
Gauze Cutting Machine
2
-
-
... More
Instrument washing Station
1
-
-
... More
Work Table for Dry & Wet Goods
5
-
-
... More
Packing Table with Two shelves
5
-
-
... More
Linen Inspection Table
5
-
-
... More
Closed Transport Trolley
3
-
-
... More
Double Column Basket Rack
5
-
-
... More
Mesh Rack
10
-
-
... More
Storage cabinet
5
-
-
... More
Static Pass Box with electrical interlocking
4
-
-
... More
Sterilizing Wire Baskets - Big
5
-
-
... More
Sterilizing Wire Baskets - Medium
8
-
-
... More
Sterilization Container - Small
10
-
-
... More
Sterilization Container - Medium
8
-
-
... More
Sterilization Container - Large
5
-
-
... More
Instrument Tray - Small
10
-
-
... More
Instrument Tray - Big
8
-
-
... More
Stool (SS)
15
-
-
... More
Cladding with service doors for Sterilisers
90
-
-
... More
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar (NOT TAKEN FOR EVALUATION)
1
-
-
... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) (NOT TAKEN FOR EVALUATION)
1
-
-
... More
Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including disposal of excavated earth upto 50 m and lift up to 1.5 m, disposed soil to be levelled and neatly dressed : All kinds of soil (NOT TAKEN FOR EVALUATION)
1
-
-
... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) (NOT TAKEN FOR EVALUATION)
1
-
-
... More
50.6.1.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc (NOT TAKEN FOR EVALUATION)
1
-
-
... More
12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand) (NOT TAKEN FOR EVALUATION)
10
-
-
... More
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption's less than 0.08%and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm (NOT TAKEN FOR EVALUATION)
10
-
-
... More
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. (NOT TAKEN FOR EVALUATION)
10
-
-
... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron) (NOT TAKEN FOR EVALUATION)
100
-
-
... More
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). Powder coated aluminium (minimum thickness of powder coating 50 micron) (NOT TAKEN FOR EVALUATION)
100
-
-
... More
Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS:12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on both sides. (NOT TAKEN FOR EVALUATION)
5
-
-
... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5.50 mm thickness (NOT TAKEN FOR EVALUATION)
5
-
-
... More
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000mm) with double speed adjustment with necessary accessories and screws etc. complete. (NOT TAKEN FOR EVALUATION)
1
-
-
... More
Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. (NOT TAKEN FOR EVALUATION)
1
-
-
... More
Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 125 mm (NOT TAKEN FOR EVALUATION)
1
-
-
... More
Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : 250x10 mm (NOT TAKEN FOR EVALUATION)
1
-
-
... More
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade : One or more coats on old work (NOT TAKEN FOR EVALUATION)
10
-
-
... More
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work (NOT TAKEN FOR EVALUATION)
10
-
-
... More
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface. (NOT TAKEN FOR EVALUATION)
10
-
-
... More
18.7.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall25 mm nominal outer dia pipes (NOT TAKEN FOR EVALUATION)
10
-
-
... More
18.7.4 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall32 mm nominal outer dia pipes (NOT TAKEN FOR EVALUATION)
10
-
-
... More
18.7.6 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall50 mm nominal outer dia pipes (NOT TAKEN FOR EVALUATION)
10
-
-
... More
Providing and fixing CPVC moulded fittings/ accessories for CPVC Valves including jointing with solvent cement - 25 mm dia (NOT TAKEN FOR EVALUATION)
1
-
-
... More
Providing and fixing PVC moulded fittings/ accessories for PVC ball Valves including jointing with solvent cement - 32 mm dia (NOT TAKEN FOR EVALUATION)
1
-
-
... More
Supply of LT Switch board cubicle type, made out of 2 mm thick CRCA sheet, totally enclosed, IP42, free standing, wall/floor mounting, dust and vermin proof, powder coated, indoor, compartmentalized, suitable for operation on 3 phase and neutral , 415 V, 50Hz AC system with bus-bars extendable on both sides, including all the necessary internal wiring , suitable spreader etc. The panel shall be fabricated from a firm having CPRI certification with test certificates for similar panel(required for short circuit rating, temperature rise and IP classification) and with following switchgears, metering instruments and accessories etc. complete as required as per drawing & specification.
RYB indicating lamps LED type
4A SP MCB (0-500) V Class 1 with 90 deg defl.
Scale.(0-200)A Class 1 with 90 deg defl.
Scale, Voltmeter selector switch 200/5 A 5 VA Class .5S CTs ON/OFF INDICATION LAMP, Digital multi-function meter to read V,A.Hz,PF,Kwh, Incomer 200A
FP Molded Case Circuit Breaker with thermal release with OL and SC protection neutral link (Ics =100%Icu= 25kA) -1 No's
200A Copper TPN busbar chamber with Copper busbar.
Out Goings 100 A FP Molded Case Circuit Breaker with Microprocessor based release with OL and SC protection neutral link (Ics =100%Icu= 25kA) - 3 No’s 63 A FP Molded Case Circuit Breaker with Microprocessor based release with OL and SC protection neutral
link (Ics =100%Icu= 25kA) - 3 No's
The panel shall be Top Entry/Exit and suitable for termination of cable system as per SLD and technical specification. (NOT TAKEN FOR EVALUATION)
1
-
-
... More
Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.
16 A-100A, 25/35 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL (NOT TAKEN FOR EVALUATION)
6
-
-
... More
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
63 amps (NOT TAKEN FOR EVALUATION)
4
-
-
... More
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
100 amps (NOT TAKEN FOR EVALUATION)
3
-
-
... More
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armored aluminum power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages, color washing etc. as required.
4 core 10 sq mm with factory made clamp (NOT TAKEN FOR EVALUATION)
30
-
-
... More
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armored aluminum power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages, color washing etc. as required.
4 core 35 sq mm with factory made clamp (NOT TAKEN FOR EVALUATION)
90
-
-
... More
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armored aluminum power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages, color washing etc. as required.
4 core 95 sq mm (NOT TAKEN FOR EVALUATION)
60
-
-
... More
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armored copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages, color washing etc. as required.
4 core 6 sq mm with factory made clamp (NOT TAKEN FOR EVALUATION)
25
-
-
... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole (NOT TAKEN FOR EVALUATION)
24
-
-
... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
63 amps (NOT TAKEN FOR EVALUATION)
1
-
-
... More
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall, making good the damages, color washing etc. as required
4 way (8+12) - three phase double cover (IP 42/43) (NOT TAKEN FOR EVALUATION)
2
-
-
... More
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required
2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire (NOT TAKEN FOR EVALUATION)
60
-
-
... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required
2 X 4 sq. mm + 1 X 4 sq. mm earth wire (NOT TAKEN FOR EVALUATION)
60
-
-
... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required
2 X 6 Sq.mm + 1 x 6 sq.mm earth wire (NOT TAKEN FOR EVALUATION)
30
-
-
... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.
3 x 2.5 sq. mm (NOT TAKEN FOR EVALUATION)
40
-
-
... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.
3 x 4 sq. mm (NOT TAKEN FOR EVALUATION)
40
-
-
... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.
3 x 6 sq. mm (NOT TAKEN FOR EVALUATION)
25
-
-
... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.
20mm (NOT TAKEN FOR EVALUATION)
30
-
-
... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.
25 mm (NOT TAKEN FOR EVALUATION)
20
-
-
... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 amp switch (NOT TAKEN FOR EVALUATION)
10
-
-
... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
15/16 amp switch (NOT TAKEN FOR EVALUATION)
12
-
-
... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
3 pin 5/6 amp socket outlet (NOT TAKEN FOR EVALUATION)
10
-
-
... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
6 pin 15/16 amp socket outlet (NOT TAKEN FOR EVALUATION)
12
-
-
... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.
1 or 2 Module (75mmX75mm) (NOT TAKEN FOR EVALUATION)
10
-
-
... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.
3 Module (100mmX75mm) (NOT TAKEN FOR EVALUATION)
6
-
-
... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.
6 Module (200mmX75mm) (NOT TAKEN FOR EVALUATION)
4
-
-
... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.
8 Module (125mmX125mm) (NOT TAKEN FOR EVALUATION)
1
-
-
... More
Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.
2.00 mm (14 SWG) (NOT TAKEN FOR EVALUATION)
60
-
-
... More
Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.
2.65mm(12SWG) (NOT TAKEN FOR EVALUATION)
90
-
-
... More
Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.
3.15 mm (10 SWG) (NOT TAKEN FOR EVALUATION)
120
-
-
... More
Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.
4.00 mm (8 SWG) (NOT TAKEN FOR EVALUATION)
20
-
-