Kerala Land Development Corporation Limited Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kerala Land Development Corporation Limited - KLDC Tender

Works
Civil And Construction
Eprocure
Opening Date29 Dec 2023
Closing Date8 Jan 2024
Tender Amount₹ 46,67,265 
Notes
Download

Costs

Summary

General Electrification Of The Work Nabard Ridf Xxvi -construction Of New Tissure Culture Lab At District Agricultural Farm(daf),neryamangalam In Ernakulam District

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
90.3.19.3 : Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required

89

-

-

... More
90.15.4.2 : Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)

12

-

-

... More
1.34 : Supplying and fixing brass batten/ angle holder including connection etc. as required.

5

-

-

... More
od283999/2023_2024 : Supply conveyance, installation, testing and commissioning the 17 W LED Mirror light fittings directly fixed on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required (Philips Ultron 17-Watt Wall Light (Cool White, Round, Metal) or its equivalent make)<br><br><br>

3

-

-

... More
od284000/2023_2024 : Supply, Conveyance, installation, testing and commissioning of surface/recess mounting down light fittings of following type directly on ceiling including giving connections with required length of 16/0.20 mm 3 core round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, making good the damages, colour washing etc. as required. (Philips make 250CLED 12S-6500PSUWH round Light or equivalent)<br><br>

53

-

-

... More
od284001/2023_2024 : SITC of Bulk head fittings Pressure die cast housing IP 65 Protection against dust and water on wall including cutting necessary holes, giving connections with the extended original wiring , making good the damages ,Colour washing etc. as required. Philips make VISTA GLOW model no. WT140W LED 7S CW PSUSPC or its equivalent.<br><br>

12

-

-

... More
od284002/2023_2024 : Supply and installing B22 type 9W, LED BULB of 100 lumen/watt with PF>0.95<br><br>

17

-

-

... More
od284003/2023_2024 : Supply, Conveyance, installation, testing and commissioning of 300/305 mm sweep Heavy Duty Exhaust fan 1400 rpm in metal frame working on 230 V A/C and giving connections etc. as required<br><br>

4

-

-

... More
od284004/2023_2024 : supply ,conveyance installation testing and commissioning of Light Duty exhaust fan of 305mm in the opening fixing necessary bolts and nuts making good the damages etc.as required including giving connection with required length of 24/0.2mmpvc insulated and pvc sheathed 3core flex wire.<br><br>

4

-

-

... More
90.4.1 : Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.

23

-

-

... More
90.4.5.2 : Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required.

23

-

-

... More
1.25 : Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

23

-

-

... More
90.4.9 : Charges for cutting holes suitable for accommodating exhaust fans above 305mm sweep and up to 450mm sweep including plastering colour washing etc. as required.

8

-

-

... More
1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)

48

-

-

... More
1.27.2 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)

45

-

-

... More
1.27.5 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)

10

-

-

... More
1.28.1 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module

48

-

-

... More
1.28.2 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module

45

-

-

... More
1.28.5 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.8 Module

10

-

-

... More
1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch

25

-

-

... More
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch

77

-

-

... More
1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet

25

-

-

... More
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet

77

-

-

... More
1.26 : Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

25

-

-

... More
1.17.3 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm

500

-

-

... More
1.17.11 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm

1000

-

-

... More
1.17.13 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 2.5 sq. mm

800

-

-

... More
1.17.15 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 2.5 sq. mm

200

-

-

... More
1.17.20 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm

400

-

-

... More
1.17.31 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 6 sq. mm

350

-

-

... More
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

1200

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

1000

-

-

... More
1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm

150

-

-

... More
90.6.4.54 : Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.

300

-

-

... More
90.6.6.5 : Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.

150

-

-

... More
90.16.1.1 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required

1500

-

-

... More
90.16.1.2 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required

800

-

-

... More
90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required

400

-

-

... More
90.16.1.4 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required

200

-

-

... More
90.16.5.1 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.

100

-

-

... More
90.16.5.2 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.

80

-

-

... More
90.16.5.3 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.

40

-

-

... More
90.16.5.4 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.

30

-

-

... More
90.12.7.27 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.

20

-

-

... More
90.12.7.28 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.

30

-

-

... More
90.12.7.29 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.

50

-

-

... More
90.12.7.30 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.

45

-

-

... More
90.12.7.31 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.

100

-

-

... More
90.12.7.34 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.

100

-

-

... More
9.1.20 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X25 sq.mm (28mm)

4

-

-

... More
9.1.21 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm)

2

-

-

... More
9.1.22 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)

2

-

-

... More
9.1.23 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)

2

-

-

... More
9.1.24 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 95 sq. mm (45mm)

4

-

-

... More
9.1.27 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)

2

-

-

... More
90.12.10.5 : Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation

80

-

-

... More
90.16.2.2 : Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.20 mm dia. G.I pipe ( medium class)

60

-

-

... More
2.3.4 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator16 way, Double door

1

-

-

... More
90.11.1.10 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required

3

-

-

... More
90.11.1.11 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required

8

-

-

... More
90.11.1.12 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required

1

-

-

... More
90.11.1.15 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required

3

-

-

... More
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

216

-

-

... More
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole

12

-

-

... More
2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

20

-

-

... More
2.12.1 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

1

-

-

... More
2.13.2 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps

2

-

-

... More
2.13.3 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.100 amps

1

-

-

... More
2.14.1 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps

1

-

-

... More
2.15.2 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

12

-

-

... More
2.15.3 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps

2

-

-

... More
90.9.2.1 : Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.

60

-

-

... More
90.9.2.3 : Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.

6

-

-

... More
90.9.2.5 : Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.

6

-

-

... More
90.9.2.8 : Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.

6

-

-

... More
2.21 : Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

2

-

-

... More
12.1 : Supplying and erection of stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, turn buckle ( 20 mm X 60 cm ), 7/ 4.00 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.

2

-

-

... More
12.11 : Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for 4 wire over head line complete with clamps, bolts, nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting with primer and finished paint as required .

6

-

-

... More
12.16 : Supplying and erection of 75 mm X 90 mm shackle insulator with G. I. Bolt, nuts and straps etc.as required .

6

-

-

... More
12.30 : Supplying and erection of 30 A aerial fuse complete as required.

3

-

-

... More
11.1.3 : Above 8.0 metre and upto 11.0 metre

4

-

-

... More
90.14.1.2 : Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.br Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.

30

-

-

... More
90.14.2.1 : Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.

14

-

-

... More
90.14.3.1 : Supply and providing heavy duty 'A' section neoprene gasket in the panel board

25

-

-

... More
90.14.4 : Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC)

5

-

-

... More
90.14.5 : Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board

1000

-

-

... More
90.14.6 : Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.

3800

-

-

... More
90.14.7 : Supply and providing copper earth bus in the panel board

300

-

-

... More
90.16.3.9 : Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)

100

-

-

... More
90.16.3.10 : Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)

150

-

-

... More
od284005/2023_2024 : Supply and providing plate earthing with 1200x1200x12mm GI earth plate,50 mm GI(medium class) watering pipe,GI funnel with weld mesh,25x5 mm GI clamps, CI/MS cover plate with locking arrangements, charcoal/coke and salt etc. including providing brick work masonry enclosure at the top (450x450x450mm inside) etc. as required.<br><br>

8

-

-

... More
5.4 : Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

7

-

-

... More
5.10 : Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.

50

-

-

... More
90.14.24.68 : Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.

2

-

-

... More
90.14.24.71 : Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.

2

-

-

... More
90.14.24.73 : Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.

2

-

-

... More
od284006/2023_2024 : Supply and providing 3 Pole Capacitor duty contactors for switching capacitor banks 15 kVAR with AC Coil, in the existing panel board and giving connection.<br><br>

2

-

-

... More
od284007/2023_2024 : Supply and providing 3 Pole Capacitor duty contactors for switching capacitor banks 10 kVAR with AC Coil, in the existing panel board and giving connection.<br><br>

2

-

-

... More
od284008/2023_2024 : Supply and providing 3 Pole Capacitor duty contactors for switching capacitor banks 5 kVAR with AC Coil, in the existing panel board and giving connection.<br><br>

2

-

-

... More
od284009/2023_2024 : Supply and Fixing of Illuminated Flush head Actuator - Green with legend 'ON', (Contact - 1 NO) and giving connection as required.<br><br>2

1

-

-

... More
od284010/2023_2024 : Supply, conveyance and fixing the following types & current rated control gears & switch gears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required. 315A 4 pole on load change over switch<br><br>

1

-

-

... More
od284011/2023_2024 : Supply and providing Sub Main Distribution Board with IP42 protection complying to IEC 61439-2 with copper bus bar neutral link earth bus etc. suitable for providing 3 pole MCCBs as incoming and outgoing fixed on wall using necessaru anchor bolts including cutting hole on the wall , making good the damages, colour washing etc. as required MCCB Load Bank L&T Energy's or equivalent 250A 4way

1

-

-

... More
od284012/2023_2024 : Supply and providing Sub Main Distribution Board with IP42 protection complying to IEC 61439-2 with copper bus bar neutral link earth bus etc. suitable for providing 3 pole MCCBs as incoming and outgoing fixed on wall using necessaru anchor bolts including cutting hole on the wall , making good the damages, colour washing etc. as required MCCB Load Bank L&T Energy's or equivalent 250A 8way

2

-

-

... More
od284013/2023_2024 : Supply and providing Mounting Base for the existing(250A bus,-4way Sub Main Distribution Board with IP42 protection complying to IEC 61439-2,Fixing on wall using necessary anchor bolts including cutting hole on the wall , making good the damages, colour washing etc. L&T make (category No.CM90437OOOO) or equivalent

3

-

-

... More
od284014/2023_2024 : Supply and providing Side cabling box (Right side/Left side ) for the existing(250A bus,-4way Sub Main Distribution Board with IP42 protection complying to IEC 61439-2,Fixing on wall using necessary anchor bolts including cutting hole on the wall , making good the damages, colour washing etc. L&T make (category No.CM90437OOOO) or equivalent

3

-

-

... More
od284015/2023_2024 : Supply and providing Bottom cabling box for the existing(250A bus,-4way Sub Main Distribution Board with IP42 protection complying to IEC 61439-2,Fixing on wall using necessary anchor bolts including cutting hole on the wall , making good the damages, colour washing etc. L&T make (category No.CM90437OOOO) or equivalent

3

-

-

... More
90.14.10.2 : Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.

15

-

-

... More
90.14.10.3 : Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.

6

-

-

... More
90.14.10.12 : Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.

3

-

-

... More
90.14.10.17 : Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.

1

-

-

... More
od284016/2023_2024 : Supply and Fixing of Spreader Terminals for 4 pole MCCB in the existing panel board and giving connections etc. as required.16A to 100A

48

-

-

... More
od284017/2023_2024 : Supply and Fixing of Spreader Terminals for 4 pole MCCB in the existing panel board and giving connections etc. as required. 160A

24

-

-

... More
od284018/2023_2024 : Supply and Fixing of Spreader Terminals for 4 pole MCCB in the existing panel board and giving connections etc. as required. 315A

8

-

-

... More
90.14.11.13 : MCCB Accessories

8

-

-

... More
90.14.11.15 : MCCB Accessories

1

-

-

... More
od284019/2023_2024 : Supply and providing Blue Colour LED indicator lamp, AC/DC, 22.5 cm cut out dia.<br><br>3

2

-

-

... More
od284020/2023_2024 : Supply and providing Red, Green, Black, Yellow, Orange colors LED indicators, AC/DC 22.5mm cut out dia<br><br>

4

-

-

... More
od284021/2023_2024 : Providing and fixing following multi function meter to read: V, A, F, 3 phase accuracy class 1 in existing panel and giving connection complete<br><br>

1

-

-

... More
od284022/2023_2024 : Supply and Fixing of Bakelite Fuse Base 16A with HRC Fuse Link 2A and giving connection as required

6

-

-

... More
od284023/2023_2024 : Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/ equipment's including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required.- 1.5 sq mm single run with required sockets.<br><br>

50

-

-

... More
od284024/2023_2024 : Supply conveyance installation of portable type ABC TYPE 4.5 KG Capacity fire extinguisher in position<br>

4

-

-

... More
od284025/2023_2024 : Supply conveyance installation of portable type CO2 TYPE 4.5 KG Capacity fire extinguisher in position<br>

10

-

-

... More
od284026/2023_2024 : supply and providing 9KV 5 KA Lightning Arrestor in position and giving connections etc. as required.

1

-

-

... More
160KVA UNITISED OUTDOOR SUBSTATION

-

-

-

... More
od283990/2023_2024 : Supply, conveyance, installation, testing and commissioning of 160 KVA out door unitised sub station comprising of H.T.panel trunked with cast resin Transformer with load break switch/ Air break switch on H.T.side and manually operated, with bottom / top entry cable box as per technical details furnished below. H.T. Portion H.T. Portion consists of (1) 1 No 11K.V, 630A, 26.30 K.A Air break/Load break switch suitable for 3 phase,3wire,50 HZ system with 20 A H.R.C. fuses with earth inter lock with main switch and mechanical ON/OFF indication,(2)shunt trip coil for the remote operation of the the load break switch, (3)1No, 0-12 K.V (or nearest range) voltmeter with selector switch,(4) Cast resin type P.T for consumer metering. Transformer Portion Supply of 250 K.V.A , 11 K.V, 50 HZ, Delta/Star connected cast resin insulated copper wound transformer. The core shall be made of high grade laser scribed core shall be protected against corrosion by epoxy resin finish. Class 'F' insulation level shall be maintained. OFF load tap changing facility shall be incorporated so as to achieve tap position of 2.5% x 4. Temperature scanner with trip annunciator, Blower for cooling shall be provided. The transformer shall confirm to IEC 726 and I.S 11171/1985 reaffirmed in 1991 . L.T.Portion The LT portion shall be provided with 1No over current earth fault relay, suitabl ratio NCT, Shunt trip in existing MCCB as required. All inter connection from HT load break switch to transformer and to LT breaker shall be given using Aluminium bus bars and support insulators. All internal earth connections are to be given as per standards. Necessary protection shall be made for giving cable connections on the HT side as well as LT side. Phase barriers and shrouding as per rules has to be given. The enclosure shall comply to IP 20 standards made of 2 mm GI sheet and shall powder coating the assembly after subjecting to 7 tank process, air ventilation arrangement etc as required. The USS shall be installed as per the directions at site.<br><br>

1

-

-

... More
od283993/2023_2024 : Supply, installation, testing and commissioning of outdoor HT metering cubicle consists of the following; A) Resin cast CT 3Nos., ratio; - /5 or -/ 1 A, 10VA Class 0.2S B) Resin cast PT 1No., 11kV/110V, 25VA, Class 0.2S C) Test terminal block for TOD meter D)3 Phase, 4 wire, 110 V (L-L), -/1 A CT or -/5A CT, accuracy class 0.2, TOD meter as per KSEB Standards E) The enclosure shall fabricated using 2mm MS sheet and shall comply with IP 65 standards with dust and vermin proof outdoor type and shall be powder coated after seven tank processing and phosphatising. 11 KV bus bar arrangement with insulator, HT cable termination, Locking facility etc as required.<br><br>

1

-

-

... More
od283994/2023_2024 : supply and providing 11KV DO Fuse in position and giving connections etc. as required<br>

1

-

-

... More
od283996/2023_2024 : supply and fixing 11KV 200A AB Switch in position and giving connection etc. as required<br>

1

-

-

... More
od283997/2023_2024 : Supply and providing 9 Liter capacity GI Fire Bucket painted in post office red with primer coat of red oxide and written with white paint 'FIRE' mounted on MS angle frame work/ wall bracket filled with fine sand, painting the bracket/ floor stand including making good the damages, colour washing etc. as required.<br>

1

-

-

... More
od283998/2023_2024 : Supply and fixing of 2.00 mm thick, 3.3 kV, Synthetic elastomeric fire retardant insulating sheet on the floor with using synthetic a 2.00 mm thick, 3.3 kV, Synthetic adhesive as required.<br><br>

4

-

-

... More
Preparation of the Drawing and Schematic diagram

-

-

-

... More
od283989/2023_2024 : Preparation of the Drawing and Schematic diagram and obtain the Application form from the Electrical Inspectorate /KSEB the actual amount may be returned on produce of original Receipts.

1

-

-

... More
od283992/2023_2024 : Charges for preparation of Electrical Schematic per A3 sheet first copy<br>

40

-

-

... More
od283995/2023_2024 : Copying charges for additional copies per A3 sheet<br>

75

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.