Kerala Khadi And Village Industries Board Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kerala Khadi And Village Industries Board Tender

Works
Civil And Construction
Eprocure
Opening Date1 Jul 2019
Closing Date15 Jul 2019
Tender Amount₹ 11,38,165 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm ( D S R 2016 , 15.23.1 )

50

-

-

... More
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. ( D S R 2016, 15.56 )

25

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). ( D S R 4.1.5 )

0.5

-

-

... More
Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. meters and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50metres lead : With cement mortar 1:4 (1 cement : 4 course sand). ( D S R 14.1.2. )

5

-

-

... More
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete ( D S R 2016 14.46 )

180

-

-

... More
Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete ( Observed Data Buildings 50.6.2.2. )

3.1

-

-

... More
12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) ( D S R 13.4.1. )

62

-

-

... More
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. ( D S R 13.26 )

190

-

-

... More
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade:  New work ( Two or more coats) over and including priming coat with water thinnable cement primer  ( D S R 2016 13.41.1 )

50

-

-

... More
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer ( D S R 13.43.1 )

190

-

-

... More
Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm). ( D S R 13.46.1. )

30

-

-

... More
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new work. ( D S R 13.60.1. )

140

-

-

... More
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work. ( D S R 13.61.1 . )

63

-

-

... More
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete. ( D S R 2016 11.37 )

17

-

-

... More
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08%and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm ( D S R 11.41 .2 )

51

-

-

... More
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 600x600 mm ( D S R 11.48.2. )

51

-

-

... More
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With stainless steel cover plate minimum 1.25 mm thickness ( D S R 21.4.1. )

1

-

-

... More
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. ( D S R 10.2. )

25

-

-

... More
Steel work in built up tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes ( D S R 10.16.1 )

300

-

-

... More
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm + 0.05 %, total coated thickness with zinc coating 120 gsm as per IS: 277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. ( D S R 12.50 )

22

-

-

... More
Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 m dia 4 Kgf/cm2 - External work - Exposed on wall ( Observed Data Buildings 50.18.9.19.2. )

17.5

-

-

... More
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow ( Observed Data Buildings 50.18.9.22.1. )

8

-

-

... More
Providing and fixing PVC, pipes fittings including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 6 Kgf/cm2 - internal work- Exposed on wall ( Observed Data Buildings 50.18.7.4.2. )

10.5

-

-

... More
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recomme-nded jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer’s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- Part I ( D S R. 12.45.1. )

54

-

-

... More
Providing and fixing powder coated aluminium work ( minimum thickness of powder coating 50 micron) consisting of tee /angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-Charge ( level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately ). 

12.5

-

-

... More
Providing and fixing false ceiling with e board classic tile or equivalent make of size 610x610x4 mm ceiling of approved quality in aluminium frame work with necessary screws etc complete ( aluminium frame work shall be paid separately)  ( APPROVED OBSERVED DATA BUILDINGS 50.12.5.1 )

16.5

-

-

... More
Providing and fixing TEAK wood frame work consisting of battens 100 x 50 mm For Fixed Glasing fixed with rawl plug and drilling necessary holes for rawl plug etc. including priming coat complete. For Fixed Glased Partitions and Doors

0.04

-

-

... More
Providing and fixing Glazing in wooden frames using 12 mm Glass of approved brand in Fixed partitions and glazed shutters for doors, (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured).

8

-

-

... More
Supplying and fixing Modiguard or Equivalent Brand glass Mirror over Frame work of Pincoda Wood or Equivalent as approved wood frame and covering the rear side with 12 MM BWR plywood and finishing the teakwood frame with lacquer polish etc. completed as per the direction of Engineer in charge.

3.8

-

-

... More
Providing and fixing KHADI SHELF ( Horizontal Spacing 90 cm and vertical Spacing 30 / 60 cm ) with stainless steel ( Grade 202 ) Hollow tubes, channels, plates etc., and 8 mm Glass , including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the Shelf to the Wall / Columns with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., Providing 8 mm Glass of of required size, including polishing the exposed edges , all as per the Drawing and approval of the Engineer-in-charge,

46

-

-

... More
Providing and fixing MATTRESS STAND ( SIZE 1.30 M X 1.90 M AND HEIGHT 0 .30 M ) with stainless steel ( Grade 202 ) Hollow tubes, channels, plates etc., and , including welding, grinding, buffing, polishing and making curvature (wherever required) all as per the Drawing and approval of the Engineer-in-charge,

1

-

-

... More
Providing and fixing Display shelf for Ornamental Items ( RACK BEHIND CASH COUNTER ) with wooden frame work using Padack wood or equvalent, providing 12 mm thick water proof ply wood on rear side, covering the frame work with 16 mm water proof ply wood, covering all the exposed surface with 9 mm thick decorative teak ply wood, providing 12 mm thic edge mechine polished glass for racks with necessary supports, polishing with Laquer polish or equivalent all as per the drawing and Direction of the Engineer .

5.2

-

-

... More
Providing and fixing Wooden Display shelf with wooden frame work using Padack wood or equvalent, covering the frame work with 16 mm water proof ply wood, covering all the exposed surface with 9 mm thick decorative teak ply wood, providing 10 mm thic edge mechine polished glass for racks with necessary supports, polishing with Laquer polish or equivalent all as per the drawing and Direction of the Engineer .

6.5

-

-

... More
Supplying fabricating and fixing in position sales counter with Granite / Glass top of 60 CM TOP WIDTH AND HEIGHT 80 CM ( AV ) ,made with frames by using PINCODA or similar wood scantling 50x50 mm section framed to form a box, Covered with 16 mm BWR ( IS 303 GRADE ) plywood . for inside rack and top with 12 mm plain glass propped over glass struts over 9 MM plywood with top width 60 to 70cm (av) and front vertical face of the counter being fixed with 16 MM BWR plywood and the vertical face is being sticked with O S T and the outer edge of glass being rounded and polishing , the inside of the counter being painted with synthetic enamel paint 2 coat over one coat of wood primer and putty leveling filling etc. complete as per the approved drawings and direction of the Engineer in charge..

7.2

-

-

... More
Supplying fabricating and erecting cash cum packing counter of 1 M height (av) with width and length 70 to 90 cm and 2.00 m respectively by using PINCODA or similar wood scantling of size 50x50 mm framed to form a box covered 16 mm B W R plywood round and top with 12 plain glass and the secound hight counter portation providing granite or marble (jet black or galaxy) over 9 mm thick plywood cupboard drawers with locking arrangement foot rest. Space for UPS CPU etc. and the edges of the granite being rounded and the exposed rack faced being painted to coat over a primer coat after applying putty levelling filling etc. complete as per the approved drawings and direction of the Engineer in charge.

1

-

-

... More
Supply and fixing Name Board by using ACP fixed over 40mm x40 mm G I sq Tube for outer frame including Sticker Work as directed by the officer in charge

3.1

-

-

... More
Supplying and fixing Good Quality Stainless Steel Door Handle for Glass Doors of size 45 cm with all necessary screws , nuts etc complete as approved by the Engineer in charge ( MR )

1

-

-

... More
"Disposal of moorum/ building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-Charge. ( D S R 1.1.18 )

10

-

-

... More
APPENDIX-II

-

-

-

... More
Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20mm conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm PVC insulated stranded sing core copper conductor cable 650V grade continuous earthing with No. 14 bare copper, required of copper earth socket, brass bolt and nut crimping/complete including circuit mains to switch board with suitable size modular type metal switch boxes, modular type front plates (white) ete, up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc., complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (Group A modular accessories) Single control light / Wall fan point with 6A 3 plate ceiling rose

51

-

-

... More
Combined plug point with 6A, 5 pin plug socket controlled by 6A switch in the same switch board as that of light points

11

-

-

... More
Do do power plug 16 A 5 pin plug socket

3

-

-

... More
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required . ( D S R 1.2 )

2

-

-

... More
Supply &Fixing the following types/sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required 1 module metal box

2

-

-

... More
3 module metal box

3

-

-

... More
12 module metal box

3

-

-

... More
Supply &Fixing the following types / sizes of front plates on the existing modular boxes 1 module white

2

-

-

... More
3 module white

3

-

-

... More
12 module white

3

-

-

... More
Supply and Fixing the following modular switches &accessories in the existing front plates and giving necessary connections as required 6 A SP 1 way switch

28

-

-

... More
6 A 2 / 3 pin socket

16

-

-

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.  6 pin 15/16 amp socket outlet ( D S R 1.24.5 )

3

-

-

... More
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required (. DSR 1.26 )

5

-

-

... More
32 A DP Swittch

3

-

-

... More
Supply and fixing the following sizes of PVC Conduit conforming to IS 9537 / 1983 part III along with all required accessories on surface including making good the damages etc as required. 20 mm dia light gauge

100

-

-

... More
Supply and drawing 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface/recess conduit as required including giving necessary connections of the following sizes. 1.00 sq mm 2 run( long light mains 10 point )

20

-

-

... More
1.00 sq mm 4 run( long light mains 10 point )

20

-

-

... More
1.50 sq mm 2 run

10

-

-

... More
1.50 sq mm 4 run

10

-

-

... More
2.50 sq mm 2 run

15

-

-

... More
4.00 sq mm 2 run

40

-

-

... More
Supply and drawing bare earthing conductors of the following sizes along with wiring/cables and giving connection as required. 2.00 mm copper conductor (14 SWG)

25

-

-

... More
2.65 mm copper conductor (12 SWG)

15

-

-

... More
3.15 mm copper conductor (10 SWG)

15

-

-

... More
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper/brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall, making good the damages, colour washing etc. as required. 4 way (8 + 12 ) three phase double cover (IP 42/43)

1

-

-

... More
Supply and installation of the following acessories suitable for 50 Hz AC supply conforming to IS 8828-1995/IEC 60898 of the following current ratings in the existing enclosure and giving connections as required 63 A four pole mini break isolator

1

-

-

... More
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.  - 63 AMPS

1

-

-

... More
6 A to 32 A, 10 kA, SP MCB

9

-

-

... More
Supply, conveyance installation testing and commissioning of ceiling mounding down light fitting Bajaj BJMMR / CRFFG 1 x 4 W L E D Warm Light square/ round type of complete with all accessories of all type directly on ceiling including giving connection with required length of 16/0.20 mm 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring etc. as required.

8

-

-

... More
Supply, conveyance installation testing and commissioning of ceiling mounding down light fitting Bajaj BJMMR / CRFFG 1 x 6 W L E D square/ round type of size 100mm ( or equivalent) complete with all accessories of all type directly on ceiling including giving connection with required length of 16/0.20 mm 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring etc. as required.

15

-

-

... More
Supply, conveyance installation testing and commissioning of ceiling mounding down light fitting Bajaj BJMMR / CRFFG 1 x 12 W L E D square/ round type of size 100mm ( or equivalent) complete with all accessories of all type directly on ceiling including giving connection with required length of 16/0.20 mm 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring etc. as required.

15

-

-

... More
Supply, conveyance installation testing and commissioning of ceiling mounding down light fitting Bajaj BJMMR / CRFFG 1 x 18 W L E D square/ round type of size 100mm ( or equivalent) complete with all accessories of all type directly on ceiling including giving connection with required length of 16/0.20 mm 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring etc. as required.

7

-

-

... More
Supply , conveyance, installation, testing and commissioning wall mounting fan of the following size using mounting brackets supplied along with the fan and giving connection with existing wire. 300 mm sweep

7

-

-

... More
Providing and fixing Flexi LED Strip for Cove Lighting (5 Metre 12 W with Driver ), Wipro / Bajaj / Philips Or Eqivalent.

40

-

-

... More
Supplying , installing , testing and commisioning CC TV System with CP Plus – 1.3 MP AHD IR D/N Dome Camera with 3.6 mm Lens IR Distance 20 meter. 4 Nos , CP Plus 4 ch. Standalone DVR with TCP / IP / LAN / Eithernet, remote, channeling, playback, motion, mobile imaging, with out HDD. 1 unit, A/C D/C Power supply 5 Amps SMPS -1 , RCA/BNC Cable Connecters - 8 nos, 2 TB HDD -1 , 1 18.5” Monitor , with Cabling with 3+1 control cable and accessories as required

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.