Kerala Irrigation Infrastructure Development Corporation Limited Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kerala Irrigation Infrastructure Development Corporation Limited - KIIDC Tender

Works
Eprocure
Opening Date3 Dec 2021
Closing Date31 Dec 2021
Tender Amount₹ 31,62,26,578 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
od220621/2021_2022 : Bailing out water Using 5HP Pump- Bailing out water with 5HP engine and pump set including conveyance to site and erection,cost of fuel, lubrication oil and other stores, pay of staff etc complete

3600

-

-

... More
od220627/2021_2022 : 60.2.4 BAILING OUT WATER USING PUMP ABOVE 10HP AND UP TO 20HP - Bailing out water with engine and pump set above 10HP and up to 20HP, including conveyance to site and erection,cost of fuel, lubrication oil and other stores, pay of staff etc complete

720

-

-

... More
APPENDIX-B-FOUNDATION AND APRON

-

-

-

... More
od220607/2021_2022 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.<br>All kinds of soil

3184.57

-

-

... More
od220612/2021_2022 : Sand Filling in Foundation Trenches as per Drawing & Technical Specification using sand zone v (jamuna sand)

1836

-

-

... More
od220613/2021_2022 : Supplying and stacking well matured straight coconut posts 25cm diameter (avg) and 3.5m long and driving down to lines and levels through variuos strata ina zig zag manner @ 1.20m c/c including all hire charges and labour for fixing , staging platform and all other appliances necessary for pile driving down for full length after pointing the bottom as directed by the Engineer in charge.

1060.5

-

-

... More
12.25.3 : Bored cast-in-situ M35 grade R.C.C. Pile Using Batching Plant, Transit Mixer and Concrete Pump excluding Reinforcement complete as per Drawing and Technical Specifications and removal of excavated earth with all lifts and lead upto 1000 m.br Pile diameter-1200 mm

761.82

-

-

... More
od221216/2021_2022 : Providing Steel Liner 10mm thick for Curbs and 8 mm thick for Steining of Wells including Fabricating and Setting out as per Detailed Drawing.

90.16

-

-

... More
12.38.B.2 : Cement Concrete for Reinforced Concrete in Pile Cap complete as per Drawing and Technical Specificationbr R C C Grade M-25 - Using Batching Plant, Transit Mixer and Concrete Pump br

724.23

-

-

... More
12.8.E.2.1 : Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications. RCC Grade M25 - With Batching Plant, Transit Mixer and Concrete Pump

18

-

-

... More
od220646/2021_2022 : Providing and laying in position cement concrete of specified grade including the cost of centering and shuttering - All work up to plinth level:<br>1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

40.32

-

-

... More
12.8.A.1 : Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications. PCC Grade M15

1264.14

-

-

... More
od221386/2021_2022 : Supply, Fitting and PlacingFusion bonded epoxy coated(confirm to IS 13620-1993) HYSD bar or TMT Reinforcement in Foundation complete as per Drawing and Technical Specifications and as per 13.6 of MORTH specifications<br>

158.55

-

-

... More
od220650/2021_2022 : Providing & making Gabion structure with Mechanically Woven Double TwistedHexagonal Shaped Wire mesh Gabion Boxes as per IS 16014:2012,MORTH Clause2500, of required size, Mesh Type 10x12(D=100 mm with tolerance of �2%), Zinic+10%Al alloy+PVC coated, Mesh wire diameter 2.7/3.7mm (ID/OD), mechanically edged/selvedged with partitions at every 1m interval and shall have minimum 10 numbersof openings per meter of mesh perpendicular to twist, tying with lacing wire of diameter2.2/3.2mm(ID/OD), supplied @3% by weight of Gabion boxes, filled with boulderswith least dimension of 200 mm, as per drawing, all complete as per directions ofEngineer-in-charge

598

-

-

... More
13.10 : Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and Technical Specification.

232.32

-

-

... More
APPENDIX C - ABUTMENT, PIERS AND ROAD SLAB

-

-

-

... More
13.5.F.P.2 : Plain/Reinforced cement concrete in sub-structure complete as per drawing and Technical Specifications RCC Grade M25 - With Batching Plant, Transit Mixer and Concrete Pump - Height upto 5m

408.33

-

-

... More
13.5.F.q.2 : Plain/Reinforced cement concrete in sub-structure complete as per drawing and Technical Specifications RCC Grade M25 - With Batching Plant, Transit Mixer and Concrete Pump - Height 5m to 10m

117.15

-

-

... More
od221907/2021_2022 : Supply, Fitting and PlacingFusion bonded epoxy coated(confirm to IS 13620-1993) HYSD bar or TMT Reinforcement in substructure complete as per Drawing and Technical Specifications and as per 13.6 of MORTH specifications

52.56

-

-

... More
od220633/2021_2022 : Furnishing and Placing RCC Grade M40 in super-structures Using Batching Plant, Transit Mixer, and Concrete Pump as per drawing and Technical Specification.<br>Height 5m to 10m as per MORTH 13.5.H.q.2<br>

53.21

-

-

... More
od220634/2021_2022 : Furnishing and Placing RCC Grade M40 Using Batching Plant, Transit Mixer and Concrete Pump as per drawing and Technical Specification.<br>For T-beam & slab - Height 5m to 10m as per MORTH 14.1D.2.2.C

494.76

-

-

... More
55.25 : Lifting, conveying and fixing the newly casted RCC covering slabs of any thickness on top of drain in position including all labour charges and miscellaneous expenses etc complete

16.08

-

-

... More
14.9 : Drainage Spouts complete as per drawing and Technical specification

48

-

-

... More
od220638/2021_2022 : Construction of RCC railing of M35 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical RCC post not to exceed 1 in 500, center to center spacing between vertical post not to exceed 2000 mm, leaving adequate space between the vertical post for expansion, complete as per approved drawings and technical specifications. as per MORTH 14.7

171

-

-

... More
od224443/2021_2022 : Supply, Fitting and Placing Fusion bonded epoxy coated(confirm to IS 13620-1993)<br>HYSD bar or TMT Reinforcement in superstructure complete as per Drawing and Technical Specifications<br>and as per14.2 of MORTH specification

54.45

-

-

... More
od220641/2021_2022 : Providing and laying of a strip seal expansion joint catering to maximum horizontal movement up to 70 mm, complete as per approved drawings and standard specifications to be installed by the manufacturer/supplier or their authorized representative ensuring compliance to the manufacturer's instructions for installation (14.22)

127.01

-

-

... More
od220643/2021_2022 : Providing and laying Cement concrete wearing coat M-30 grade including reinforcement<br>complete as per drawing and Technical Specifications.<br>

46.13

-

-

... More
13.14 : Supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to IRC: 83 (Part-II) section IX and clause 2005 of MoRTH specifications complete including all accessories as per drawing and Technical Specifications.

1280000

-

-

... More
13.10 : Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and Technical Specification.

79.08

-

-

... More
od220649/2021_2022 : PVC WEEP HOLES- Providing weep holes using 75mm dia. PVC pipes working pressure 4kg /sq.cm including cost of materials, conveyance, labour charges etc. complete.

204

-

-

... More
APPENDIX D1- MECHANICAL WORKS-FABRICATION, SUPPLY AND ERECTION OF MS AND SS EMBEDDED PARTS(SS304 L Grade) FOR 4 NOS. OF REGULATOR SHUTTERS

-

-

-

... More
85.101 : Supply of MS plates confirming to IS 2062GrB including cost of conveyance charges

7578.53

-

-

... More
85.102 : Supply of MS Tees, Angles, Joists, ISMB, ISMC confirming to IS2062GrA/B including cost of conveyance charges

3320.28

-

-

... More
85.107 : Supply of MS round bar including cost of conveyance charges

407

-

-

... More
od220616/2021_2022 : Supply of MS Bolts and Nuts

380.64

-

-

... More
85.108 : Fabrication, erection and commissioning of Structural steel Embedded parts in IS2062 Grade and accessories as per approved specifications, drawings and directions of deptl officer at site including cost of labour , machinery , incidental and handling charges etc complete but excluding cost of material already supplied

10301.01

-

-

... More
od220625/2021_2022 : Fabrication, supply, erection and assembling of wheel track, sill seat and seal track in correct position and alignment by welding SS embedded parts in 304L Grade as per approved specifications, drawings and directions of deptl officer at site including cost of all materials, labour, welding, shearing, grinding etc, lead and lift, conveyance, incidental and handling etc complete.<br>Rate analysis SS embedded parts 2.6Qtl

943.45

-

-

... More
APPENDIX D2- MECHANICAL WORKS- SHUTTER

-

-

-

... More
85.101 : Supply of MS plates confirming to IS 2062GrB including cost of conveyance charges

32261.19

-

-

... More
85.102 : Supply of MS Tees, Angles, Joists, ISMB, ISMC confirming to IS2062GrA/B including cost of conveyance charges

1195.77

-

-

... More
85.107 : Supply of MS round bar including cost of conveyance charges

12.28

-

-

... More
85.110 : Fabrication and supply of Structural steel wheel gate and accessories as per approved specifications, drawings and directions of deptl officer at site including cost of labour, machinery, all leads and lifts, incidental and handling charges etc complete but excluding cost of material already supplied

47122.7

-

-

... More
85.111 : Erection of the gates safely in the grooves , assembling and aligning including cost of all machinery, labour all incidental and conveyance charges etc complete as per direction of departmental officer at site

47122.7

-

-

... More
od220616/2021_2022 : Supply of MS Bolts and Nuts

105.6

-

-

... More
85.116 : Supplying and fixing in correct position with specified initial interface the flat type rubber seal confirming to IS 11855 to the gates including cost of SS bolts and nut all labour and machinery and incidental and conveyance charges complete as per approved specification and drawing

42.8

-

-

... More
85.117 : Supplying and fixing in correct position with specified initial interface the Angular type rubber seal confirming to IS11855 to the gates including cost of SS bolts and nuts and all labour and machinery and incidental and conveyance charges complete as per approved specifications and drawings

16

-

-

... More
85.118 : Supplying and fixing in correct position with specified initial interface L-type / bulb nose rubber seal confirming to IS11855 to the gates including cost of SS bolts and nuts and all labour and machinery and incidental and conveyance charges complete as per approved specifications and drawings

16

-

-

... More
85.122 : Supplying and fixing cast steel thrust roller assembly having 300mm Dia, 90mm tread width, SS(304) shaft and 22316E self aligning spherical roller bearing and accessories as per approved specifications and drawings including cost of all materials, machineries, labour , all lift and lead, incidental and conveyance charges etc complete

16

-

-

... More
85.112 : Painting all the exposed surfaces of the gate and embedded parts with two coats of epoxy coal tar black paint confirming to IS14948 with a minimum film thickness of 150+/-5 microns per each coat over two coats of priming coat applied with zinc primer containing not less than 85% of zinc dry film with a film thickness of 70+/-5 microns , so that the total film thickness of all coats including priming coat at any rate is not less than 350microns over the grit blasted and cleaned surface to class A standard of IS 14177 including cost of all materials , labour charges , cost of testing all painting materials, all incidental charges, hire of T&P etc complete as per the direction of departmental officer at site

836.59

-

-

... More
APPENDIX D 3 - MECHANICAL WORKS- HOISTING BRIDGE AND UNITS

-

-

-

... More
85.101 : Supply of MS plates confirming to IS 2062GrB including cost of conveyance charges

28831.15

-

-

... More
85.102 : Supply of MS Tees, Angles, Joists, ISMB, ISMC confirming to IS2062GrA/B including cost of conveyance charges

10997.78

-

-

... More
85.107 : Supply of MS round bar including cost of conveyance charges

52.35

-

-

... More
85.103 : Supply of MS checquered plates including cost of conveyance charges

6775.49

-

-

... More
od220619/2021_2022 : Supply of NB 32mm GI pipe

154

-

-

... More
od220616/2021_2022 : Supply of MS Bolts and Nuts

322.16

-

-

... More
85.124 : Fabrication and supply of Hoisting bridge unit in structural steel confirming to IS2062Gr including ladder, covers for hoisting unit etc as per approved specifications, drawings and directions of deptl officer at site including cost of labour, machinery, incidental and handling charges for fixing handrails and allied works etc complete but excluding material already supplied and weight of pipes for hand rails etc

47353.32

-

-

... More
85.136 : Erection of the hoisting bridge unit including handrails , ladder and platform etc. in correct alignment and anchoring it ; setting and aligning the covers of the hoisting unit etc complete including cost of all labour, machinery, incidental and conveyance , lead and lift charges etc complete but excluding cost of materials already supplied

47390.73

-

-

... More
od220629/2021_2022 : Painting the exposed surface of the hoist and supporting structure with two coats of synthetic enamel paint conforming to IS 2932 with minimum film thickness of 25+/-5 micron per each coat over one coat of of alkayed based micaceous iron oxide paint with minimum film thickness 65+/-5 micron over 2 coats of zinc phosphate primer with film thickness of 40+/-5micron per coat so that the film thickness of all coats including priming coat not les than 175 micron over grit blasting the surface to class B standard of IS1 4177 including cost of all material labour testing of paint, incidental charge, hire of Tand P

1232.95

-

-

... More
APPENDIX D-4 MECHANICAL WORKS-HOISTING UNITS

-

-

-

... More
85.132 : Supplying and stacking of 20 Tonne capacity rope drum hoisting unit having13.5 m lift at a hoisting speed of about 0.50 m/min(+/-10%) through pulley arrangements with 4 numbers of falls on either side with 20mm tested galvanized wire rope 6/36 construction, fibre core having breaking capacity 23853Kg and driven by TEFC squirrel cage induction motor hoist duty type having capacity not less than 5HP and driven through self locking worm reducer and open gear reduction unit excluding the cost of line shaft but including 2 nos. of plummer blocks for line shaft with bearings supported at proper intervals and including cost of electro magnetic thruster brake assembly manual operating systems, electrical accessories like DOL starters, limit switch, main switches and other safety equipments as per drawings specifications and statutory requirements etc complete but excluding cost of wire rope

4

-

-

... More
85.128 : Providing Line shaft ,material : MS rolled/ forged steel

100.8

-

-

... More
od220620/2021_2022 : Cost of supplying and stacking 20mm tested galvanised steel wire rope 6/36<br>construction, fibre core having breaking capacity 23853Kg tensile designation of 1770 confirming to IS2266-2002

320

-

-

... More
od220623/2021_2022 : Providing DIAL ASSEMBLY

4

-

-

... More
85.125 : Conveying and erecting in position the already supplied rope drum hoisting units (15T/ 20T/25T/30T) capacity on the hoisting bridge and correcting the alignment as far as possible manually as per the direction of departmental officer at site including cost of all labour, machinery, lead and lift and all incidental and conveyance charges etc complete

4

-

-

... More
85.135 : Conveying and Fixing wire rope already supplied to the new gates and Hoisting unit safely and conducting Trial run

4

-

-

... More
Appendix-E- Electrification

-

-

-

... More
od220608/2021_2022 : Supplying, installation, testing & commissioning of cubical type LT panel board of suitable size for 415V, 3 phase, 4 Wire 50 Hz AC supply system having a provision of cable end termination chambers suitable for single run of 3.5 X 70 Sq.mm size cable and single run of 3.5x35sq.mm cable for incomer switches and fabricated in compartmentalized design from CRCA sheet steel of 2mm thick for frame work and covers complete with powder coating in approved shade, having suitable capacity TPN Copper bus bars, base frame of MS channel 75mm x 40 mm size, panel shall have common copper earth bar of size 25mm x 3mm in entire width of the board with 2 Nos. earth stud, cable alleys, removable gland plates, including providing following switch gears and as required.Main Panel : Incomer - 100A, 25 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL - 2nos. With following accessories:Castle key inter lock between incomers.Earth fault module with in built CBCT for KSEB incomer. Phase indication lamps controlled by 2A MCBs - 2 set. Bus Bar: 100Amps TPN Copper busbars, colour coded with heat shrinkable insulation sleeves (after derating). Out goings: 32ATPN MCB- 1no. and25A TPN MCB-11nos

1

-

-

... More
90.12.41.33 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 4 core 10 sq mm with factory made clamp

1000

-

-

... More
90.12.41.21 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 3.5 core 35 sq mm with factory made clam

20

-

-

... More
90.12.37.23 : Supply & laying of one number PVC insulated and PVC sheathed armoured copper power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil)..3.5 core 70 sq mm

50

-

-

... More
9.1.21 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm)

4

-

-

... More
9.1.23 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)

3

-

-

... More
9.2.20 : Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 70 sq. mm

1

-

-

... More
4.1.1 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6 mm thickness

50

-

-

... More
4.1.3 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.225 mm width X 50 mm depth X 1.6 mm thickness

100

-

-

... More
5.4 : Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

5

-

-

... More
5.13 : Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.

30

-

-

... More
5.19 : Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.

150

-

-

... More
5.14 : Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.

3

-

-

... More
5.15 : Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

150

-

-

... More
od220635/2021_2022 : Supply and fixing 100A TPN SDF on wall using suitable steel fastners.

1

-

-

... More
od220636/2021_2022 : Supply & installation of dust and vermin proof, 3 Phase Syntex Meter Board GS-MB-6535(size 760x450x260x) and to fix KSEB meters, fuse units, CT etc as required including fixing it on wall, making good the damages colour washing etc. as required.

1

-

-

... More
od220637/2021_2022 : 100A HRC fuse fuse base with fuse link

3

-

-

... More
od220639/2021_2022 : 100 A, 415 V, 2 way neutral link mounted on DMC/ SMC base.

1

-

-

... More
od220640/2021_2022 : (Chalakudy) 7.7: Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS<br>3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets<br>etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with<br>two or more coats of synthetic enamel paint of required shade complete as required : 100mm dia

6

-

-

... More
90.12.9.5 : Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench 90/75 mm or nearest size

150

-

-

... More
od220642/2021_2022 : Supply, installing, testing and commissioning of Fire Extinguisher dry chemical powder type ISI mark, 5 kg capacity with initial charger and installation brackets.Make - Safex / Warrior / Intime

2

-

-

... More
od220644/2021_2022 : Supply of 11KV electrical gloves (Vidyut)

2

-

-

... More
od220645/2021_2022 : Supply and providing 2.5mm thick, 11KV grade, synthetic elastometric fire retardant insulating sheet

6

-

-

... More
od220647/2021_2022 : Supply, conveyance, installation, testing and commissioning of 40KVA/32KW D.G. set incorporating "CUMINS" Model X3.TAA-G2 Diesel Engine developing 56BHP at 1500rpm, Water cooled, 4cylinders, Coupled, ALternator rated at 32kw/40KVA, 415V, 50Hz, 0.8 P, mounted on a chanel iron base frame complete with fuel tank, Battery, Manuel control panel and other standard accessories with suitable CPCB approved factory assembled Acoustic enclosure.

1

-

-

... More
1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C

4

-

-

... More
1.12 : Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.

25

-

-

... More
1.25 : Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

1

-

-

... More
1.33 : Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.

4

-

-

... More
1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).

1

-

-

... More
90.3.20.3 : Supply & installation of light fittings on TW round block br Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required. 1200 mm 1X20W LED Lamp with box type fixture

3

-

-

... More
90.11.1.10 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 4 way (8+12) - three phase double cover (IP 42/43)

1

-

-

... More
2.15.2 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

1

-

-

... More
2.10.5 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral

1

-

-

... More
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

12

-

-

... More
od220651/2021_2022 : Supply and providing 9 Litre capacity GI Fire Bucket painted in post office red with primer coat of red oxide and written with white paint 'FIRE' mounted on MS angle frame work/ wall bracket filled with fine sand, painting the bracket/ floor stand including making good the damages, colour washing etc. as required.(MR)

2

-

-

... More
od220652/2021_2022 : Supply and installation 7M long single arm galvanised octogonal pole with 22x200x12mm base plate, 4nos. 20mm dia 600mm foundation bolt, space for mounting control switch box with inspection type door at bottom, including fixing smart pack junction box with 6A SP MCB and stud terminal inside pole etc. complete (Bajaj BOP7030/equivalent

10

-

-

... More
od220653/2021_2022 : Supply and installation of 70W LED street light fitting aluminium casing, toughened glass cover, assemitris beam angle of 130x50 degree with typical luminaire efficiency >85 lumen/watt, IP66 protection on existing GI pipe and giving connection.(Bajaj /Havells/equivalent

10

-

-

... More
Appendix -F-Approach road and Embankment formation

-

-

-

... More
3.18 : Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2

930

-

-

... More
4.1.A.1 : Construction of granular sub-base by providing graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 br Grading-I - Plant Mix Method

555

-

-

... More
4.12 : Providing, laying, spreading and compacting graded stone aggregate to Wet Mix Macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.

628.13

-

-

... More
5.4.2a : Dense Graded Bituminous Macadam :- For Grading II (26.5 mm nominal size)br Providing and laying dense graded bituminous macadam with 80-100 TPH HMP producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder (VG 30) @ 4.0 to 4.5 per cent by weight of total mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MoRTH specification clause No. 505 complete in all respects.

125.63

-

-

... More
5.6.2.a : Providing and laying bituminous concrete with 80-100 TPH hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder( NRMB) @ 5.4 per cent of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 507 complete in all respects Grading - II (13.2 mm Nominal Size)br

75.38

-

-

... More
2.3.2.A : Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness br In area of light jungle - By Mechanical Meansbr

0.5

-

-

... More
2.1.1 : Cutting of trees, including cutting of trunks, branches and removal of stumps, roots, stacking of serviceable material with all lifts and up to a lead of 1000 metres and earth filling in the depression/pit.br Girth from 300 mm to 600 mm

15

-

-

... More
2.1.3 : Cutting of trees, including cutting of trunks, branches and removal of stumps, roots, stacking of serviceable material with all lifts and up to a lead of 1000 metres and earth filling in the depression/pit. br Girth from 900 mm to 1800 mm

10

-

-

... More
3.19.2 : Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction.

140

-

-

... More
3.16 : Construction of embankment with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2.

4803.75

-

-

... More
od222146/2021_2022 : Sand Filling in Foundation Trenches as per Drawing & Technical Specification using<br>sand Zone V (Jamuna sand )

561.38

-

-

... More
od222147/2021_2022 : Supplying and stacking well matured straight coconut posts 25cm diameter (avg) and 3.5m long and driving down to lines and levels through variuos strata ina zig zag manner @ 1.20m c/c including all hire charges and labour for fixing , staging platform and all other appliances necessary for pile driving down for full length after pointing the bottom as directed by the Engineer in charge.<br>

2394

-

-

... More
od220631/2021_2022 : Furnishing and Placing RCC Grade M40 Using Batching Plant, Transit Mixer and Concrete Pump as per drawing and Technical Specification.<br>For T-beam & slab - Height 5m to 10m as per MORTH 14.1D.2.2.C<br>

16.2

-

-

... More
od225262/2021_2022 : BBored cast-in-situ M30 grade R.C.C. Pile Using Concrete Mixer excluding Reinforcement<br>complete as per Drawing and Technical Specifications and removal of excavated earth<br>with all lifts and lead upto 1000 m.<br>Pile diameter-1000 mm

2784

-

-

... More
od220605/2021_2022 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means<br>over areas exceeding 30 cm in depth, including disposal of excavated earth, with all lead and lift, disposed<br>earth to be levelled and neatly dressed and as directed by Engineer in charge.All kinds of soil<br>

1677

-

-

... More
od221216/2021_2022 : Providing Steel Liner 10mm thick for Curbs and 8 mm thick for Steining of Wells including Fabricating and Setting out as per Detailed Drawing.

82.35

-

-

... More
12.38.B.2 : Cement Concrete for Reinforced Concrete in Pile Cap complete as per Drawing and Technical Specificationbr R C C Grade M-25 - Using Batching Plant, Transit Mixer and Concrete Pump br

1677

-

-

... More
od224856/2021_2022 : :Supply, Fitting and PlacingFusion bonded epoxy coated(confirm to IS 13620-1993)<br>HYSD bar or TMT Reinforcement in Foundation complete as per Drawing and Technical Specifications and<br>as per 13.6 of MORTH specifications

238.51

-

-

... More
13.5.F.P.2 : Plain/Reinforced cement concrete in sub-structure complete as per drawing and Technical Specifications RCC Grade M25 - With Batching Plant, Transit Mixer and Concrete Pump - Height upto 5m

702

-

-

... More
od221907/2021_2022 : Supply, Fitting and PlacingFusion bonded epoxy coated(confirm to IS 13620-1993) HYSD bar or TMT Reinforcement in substructure complete as per Drawing and Technical Specifications and as per 13.6 of MORTH specifications

71.82

-

-

... More
od220648/2021_2022 : PVC WEEP HOLES- Providing weep holes using 75mm dia. PVC pipes working pressure 4kg /sq.cm including cost of materials, conveyance, labour charges etc. complete.

800

-

-

... More
13.10 : Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and Technical Specification.

702

-

-

... More
5.1.a : Providing and applying primer coat with bitumen emulsion ( SS) on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.70 - 1.0 kg/sqm using mechanical means.

2512.5

-

-

... More
5.2.a : Providing and applying tack coat with bitumen emulsion( RS) using emulsion pressure distributor at the rate of 0.20 - 0.30 kg per sqm on the prepared bituminous surface cleaned with mechanical broom.

2512.5

-

-

... More
55.16 : Providing and fixing guard postbrProviding and fixing guard post of size 200mmx200mm, 1400mm long, 800mm above ground level and 600mm below GL. casted in M20 Grade concrete reinforced with 4 nos of 8mm dia longitudinal bars and 6mm dia stirrups @ 100mm c/c, firmly fixed in position by means of foundation of size 0.5mx0.5mx0.7m in M15 grade concrete below ground level including painting 2 coats on exposed surface with synthetic enamel paint in alternate white & black band 20cm wide

280

-

-

... More
8.4.4 : Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign with 7years warranty manufactured as per IRC :67 made of Type IV micro prismatic grade sheeting vide clause 801.3.3 fixed over aluminium sheeting, 2 mm thick/ aluminium composit material sheeting 4 mm thick with suitable back supporting frame of MS angle 25x25x3 and supported on GI pipe pole 50mm NB confirming to IS 1239 firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete min size 45 cm x 45 cm x 60 cm, 60 cm below ground level including painting all exposed surface with 2 coats of epoxy painting over epoxy primer and as per approved drawing and clause 801 including lettering symbols etc.br 80 mm x 60 mm rectangular

4

-

-

... More
8.13 : Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads on Bituminous Surface @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.

112.92

-

-

... More
8.23.A : Providing and erecting a "W" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 811.3 br

200

-

-

... More
8.35 : Providing and fixing reflective road studs (Raised Pavement Marker) of ' category A' made out of ASA/HIPS/ABS moulded body with shanks and conforming to ASTM D 4280, strong enough to support a load of more than 13.635 T when tested in accordance with ASTM D 4280, reflective panel confirming to ASTM D 788, and reflectivity conforming to clause 804.4. including installation, drilling, fixing with adhesive etc. with 2 years warranty for the road stud as well as for in field performance as per clause 804.7.3 Road Markers/Road Stud with Lense Reflector :-

600

-

-

... More
55.10.1 : Providing and erecting retro-reflectorised Object Hazard Marker 300mm x 900mm brProviding and erecting retro-reflectorised Object Hazard Marker sign with 07 years warranty, manufactured as per IRC 67 USING Type IV ASTM D 4956-09 micro prismatic retro reflective sheeting fixed over aluminium sheetig, 2 mm thick / aluminium composit material sheeting 4 mm thick with suitable back support frame and supported on a mild steel angle iron post 75mmx75mmx6mm, firmly fixed 30cm above ground level by means of properly designed foundation with M 15 grade cement concrete 30cmx30x45cm, 45cm below ground level including painting all non-reflective faces with epoxy paint 2 coats over epoxy primer as per approved drawing and clause 801.br300 mm x 900 mm

4

-

-

... More
Appendix G1-Bank Protection-Retaining wall

-

-

-

... More
od220605/2021_2022 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means<br>over areas exceeding 30 cm in depth, including disposal of excavated earth, with all lead and lift, disposed<br>earth to be levelled and neatly dressed and as directed by Engineer in charge.All kinds of soil<br>

2124.4

-

-

... More
od223301/2021_2022 : Bored cast-in-situ M30 grade R.C.C. Pile Using Batching Plant, Transit Mixer and Concrete<br>Pump excluding Reinforcement complete as per Drawing and Technical Specifications and<br>removal of excavated earth with all lifts and lead upto 1000 m.<br>Pile diameter-600 mm

576

-

-

... More
od221216/2021_2022 : Providing Steel Liner 10mm thick for Curbs and 8 mm thick for Steining of Wells including Fabricating and Setting out as per Detailed Drawing.

28.4

-

-

... More
12.38.B.2 : Cement Concrete for Reinforced Concrete in Pile Cap complete as per Drawing and Technical Specificationbr R C C Grade M-25 - Using Batching Plant, Transit Mixer and Concrete Pump br

282

-

-

... More
od224856/2021_2022 : :Supply, Fitting and PlacingFusion bonded epoxy coated(confirm to IS 13620-1993)<br>HYSD bar or TMT Reinforcement in Foundation complete as per Drawing and Technical Specifications and<br>as per 13.6 of MORTH specifications

68.9

-

-

... More
13.5.F.P.2 : Plain/Reinforced cement concrete in sub-structure complete as per drawing and Technical Specifications RCC Grade M25 - With Batching Plant, Transit Mixer and Concrete Pump - Height upto 5m

398.4

-

-

... More
od221907/2021_2022 : Supply, Fitting and PlacingFusion bonded epoxy coated(confirm to IS 13620-1993) HYSD bar or TMT Reinforcement in substructure complete as per Drawing and Technical Specifications and as per 13.6 of MORTH specifications

39.84

-

-

... More
Appendix G2- Bank Protection-Pile and Slab

-

-

-

... More
od220606/2021_2022 : Pre-cast RCC piles 5.50mx.30mx.30m with pointed end and haunch on side as per drawing and technical specification in cement concrete M30 mix using 20mm nominal broken stone including all cost of form work ,watering ,curing etc complete excluding cost of reinforcement ,casting at contractors own yard near site of work etc complete

309.73

-

-

... More
od220609/2021_2022 : Precast reinforced cement concrete slabs required size in cement concrete M30 mix by using 20mm nominal size broken stone including all cost of form work ,watering ,curing etc complete by casting at contractors own yard near the site of work etc .complete excluding the cost of reinforcement

161.46

-

-

... More
od220614/2021_2022 : Lifting ,handling ,hoisting ,aligning,fixingand Driving down RCC piles 300mm.square through various strata from the bed level till refusal of monkey weighing not less ghan 2 ton with the aid of pile driving plant winches ,barge and accessories wire rope etc including labour ,lubricant oil ,pay of staff etc complete

2408

-

-

... More
od220617/2021_2022 : Conveying lifting, handling ,hoisting ,aligning and setting in position ,the precast RCC slab resting on haunch as per the drawings and technical specification .

159.3

-

-

... More
od220622/2021_2022 : Conveying precast RCC piles 300mm square, 5.5m length with haunch on side from the place of casting to the site including hire charges of the boat, coir boats crow bars etc. complete.

602

-

-

... More
od220624/2021_2022 : Chipping and removing the top of the R.C.C piles to lines and levels carefully without damaging the remaining portion and removing the debris upto a distance of 150m ,stacking etc complete .specification as per 15.3 of DAR

16.25

-

-

... More
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

62.8

-

-

... More
od220626/2021_2022 : Providing and laying in position machine batched and machine mixed design mix<br>M-30 grade cement concrete for reinforced cement concrete work, using cement<br>content as per approved design mix, including pumping of concrete to site of<br>laying but excluding the cost of centering, shuttering, finishing and reinforcement,<br>including admixtures in recommended proportions as per IS: 9103 to accelerate,<br>retard setting of concrete, improve workability without impairing strength and<br>durability as per direction of Engineer-in-charge.“(Note :- Cement content<br>considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design<br>mix is payable/recoverable separately).

62.8

-

-

... More
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

1141.5

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

80.1

-

-

... More
Appendix G3 - Natural Protection

-

-

-

... More
od220603/2021_2022 : Providing and driving Bamboo piling consisting of superior quality100 mm dia (Average) bamboo post placed vertically 250 mm c/c up to a depth of 2.5m , fixed together with horizontal running members of half cut well matured bamboo of superior quality 100 mm. dia (average) 250 mm c/c and 2 Nos inclined Memberof half cut well matured bamboo of superior quality 100 mm dia(average) fixed with nails and G.I wire etc complete as per direction of Engineer-in-charge. /m. length

9150

-

-

... More
50.2.26.1 : Filling with contractor own earth (excluding rock) in open areas in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge.

22237

-

-

... More
od220618/2021_2022 : Strengthening the slopes of the earthen bund using coir-geotextiles aided vegetative turfing including all cost of materials labour charges conveyance and all other incidental charges involved etc complete as per standard specification and as directed by departmental officers at site

35400

-

-

... More
Appendix-G4-Sluice

-

-

-

... More
12.1.B.1 : Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. br Ordinary Soil - Depth upto 3m - Mechanical Means br

75.6

-

-

... More
od220611/2021_2022 : RING BUND Type-I-Putting up ring bund as per approved shape 2.5m bottom width, 1m top width using empty gunny/polythene bags filled with earth placed in 2 rows at 0.6m apart and filled in between with puddle clay to form bund for an average height 2.00m including labour dismantling the bund after completion of the work etc. complete.

100

-

-

... More
od220615/2021_2022 : Bailing out water using pump above 5 HP and Up to 10 HP-Bailing out water with engine and pump set above 5HP and up to 10HP, including conveyance to site and erection,cost of fuel, lubrication oil and other stores, pay of staff etc complete

240

-

-

... More
12.4 : Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.

11.34

-

-

... More
13.5.F.P.1 : Plain/Reinforced cement concrete in sub-structure complete as per drawing and Technical Specifications RCC Grade M25 - Using concrete Mixer - Height upto 5m

28.05

-

-

... More
12.8.E.2.1 : Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications. RCC Grade M25 - With Batching Plant, Transit Mixer and Concrete Pump

33.6

-

-

... More
od221386/2021_2022 : Supply, Fitting and PlacingFusion bonded epoxy coated(confirm to IS 13620-1993) HYSD bar or TMT Reinforcement in Foundation complete as per Drawing and Technical Specifications and as per 13.6 of MORTH specifications<br>

1.68

-

-

... More
od221907/2021_2022 : Supply, Fitting and PlacingFusion bonded epoxy coated(confirm to IS 13620-1993) HYSD bar or TMT Reinforcement in substructure complete as per Drawing and Technical Specifications and as per 13.6 of MORTH specifications

1.41

-

-

... More
Appendix -H-Generator cum watchman room

-

-

-

... More
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

120

-

-

... More
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

33.72

-

-

... More
60.7.2 : DR PACKING Under foundation - Dry stone packing under foundation with good quality blasted rubble including conveyance of material and labour charges etc. complete as per direction of departmental officers at site.

6.91

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

7.64

-

-

... More
5.2.2 : Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)

10.66

-

-

... More
5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size

7.45

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

19.2

-

-

... More
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

70.87

-

-

... More
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

76.45

-

-

... More
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

35.76

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

1796.2

-

-

... More
7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)

15.66

-

-

... More
50.6.2.1 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15 cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15cm in: CM 1:6 ( 1 cement :6 coarse sand) etc complete

13.06

-

-

... More
9.1.1 : Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood

0.18

-

-

... More
9.5.1.1 : Providing and fixing panelled or panelled and glazed shutters for shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessery screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer - in-charge.Second class teak woodProviding and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) Second class teak wood 35 mm thick shutters

1.69

-

-

... More
9.9.1.1 : Providing and fixing glazed shutters for door, windows and clerestory windows using 4 mm thick float glass panes including ISI marked M.S. Pressed butt hinges bright finished of required size with necessary screws.Second class teak wood35 mm thick

4.03

-

-

... More
9.48.1 : Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding

154.8

-

-

... More
9.53 : Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

14

-

-

... More
9.97.3 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:200x10 mm

2

-

-

... More
9.100.2 : Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:100 mm

2

-

-

... More
9.103 : Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS: 1868) aluminium lever handles of approved quality with necessary screws etc . complete.

1

-

-

... More
9.119 : Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wall thickness of 5 mm, made out of extruded 5 mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos. of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door fame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer's specification and direction of Engineer-in Charge.

5.1

-

-

... More
9.120.1 : Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and sized of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC 'C' channel of size 30 mm thickness, 70 mm width out of whicj 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5mm thick, 95 mm wide PVC sheet out of which75 mm shall be tapered in 45 degree on th inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mmx2) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail. paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded /sealed to the styles & rails with 7 mm (5 mm + 2 mm ) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive etc. complete as per direction of Engineer -in-charge, manufacture's specification & drawing.30 mm thick plain PVC door shutters

1.89

-

-

... More
14.29 : Providing and fixing M.S. round or squre bars with M.S. flats at required spacing in wooden frames of windows and clerestory windows.

35.25

-

-

... More
50.9.15.1 : Supplying and fixing 200 mm Aluminium aldrop

1

-

-

... More
50.9.15.3 : Providing and fixing iron hooks and eyes : 200mm.

5

-

-

... More
50.9.15.5 : Providing and fixing iron hooks and eyes: 100 mm

10

-

-

... More
50.18.7.4.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10Kgf/cm2- Internal work - Exposed on wall

50

-

-

... More
50.18.8.9.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2

20

-

-

... More
50.18.9.22.4 : Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend

2

-

-

... More
13.4.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand)

338.32

-

-

... More
13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)

69.24

-

-

... More
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer

379.16

-

-

... More
13.46.1 : Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

111.72

-

-

... More
13.48.3 : Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture

17.27

-

-

... More
13.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work

389.36

-

-

... More
13.62.1 : Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture .

8.78

-

-

... More
11.38 : Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of Ist quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 Coarse sand), including pointing the joints with white cement and matching pigments etc., complete.

20.69

-

-

... More
17.3.1 : Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid

1

-

-

... More
17.7.3 : Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps

1

-

-

... More
18.48 : Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

1000

-

-

... More
51.19.ST1 : Supplying and installing ready made PVC Septic tank including the cost of carriage, trenching, placing at the level below ground level as specified as per the direction of engineer in charge (Provision for CC/RCC/Sand/06mm aggregate for the preparation of bed shall be paid separately)br 1. Below 15 flush capacity

1

-

-

... More
od220655/2021_2022 : Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622<br>(thickness to be specified by the manufacturer), of approved make, in all colours,<br>shades except burgundy, bottle green, black of any size as approved by Engineerin-<br>Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement<br>mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @<br>3.3kg per sqm, including pointing in white cement mixed with pigment of<br>matching shade complete.

12.24

-

-

... More
10.2 : Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

45

-

-

... More
10.5.1 : Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces

2.1

-

-

... More
10.6.2 : Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.20 mm M.S. laths with 1.20 mm thick top cover

3.15

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.