Kerala Irrigation Infrastructure Development Corporation Limited Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kerala Irrigation Infrastructure Development Corporation Limited - KIIDC Tender

Works
Civil And Construction
Eprocure
Opening Date23 Dec 2022
Closing Date7 Jan 2023
Tender Amount₹ 1,72,01,226 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

25.74

-

-

... More
4.3.1 : Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns

38.21

-

-

... More
5.33.1 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level

56.37

-

-

... More
5.33.2 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level

92.38

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

65.47

-

-

... More
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

164.94

-

-

... More
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

348.28

-

-

... More
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

458.86

-

-

... More
5.11.1 : Extra additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5m, for every additional height of 1 metre or part thereof (Plan area to be measured).Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)

232.92

-

-

... More
5.9.16.1 : Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide

247.43

-

-

... More
5.9.19 : Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges

81.81

-

-

... More
5.9.7 : Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)

18.16

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

18655.57

-

-

... More
5.35 : Add for using extra cement in the items of design mix over and above the specified cement content therein

74.33

-

-

... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

225.05

-

-

... More
50.2.25.1 : Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge

74.66

-

-

... More
4.11 : Providing and laying damp-proof course 50 mm thick with cement concrete 1:2:4(1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).

28.78

-

-

... More
od198907/2022_2023 : Modified 4.13 Applying a coat of Inertol Poxitar Coal tar epoxy coating per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.<br>

28.78

-

-

... More
od198908/2022_2023 : OD Applying Antitermite treatment on flooring using second generation chemicals (Anti Termite PREMISE 350 SC IMIDACLOPRID) which is ecofriendly and nil harmful for human beings and pet animals which control the pests including all cost and labour charges etc. complete<br>

136.97

-

-

... More
50.6.7.1 : Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for foundation and basement including all cost of materials, labour charges etc.

11.1

-

-

... More
50.6.3.1 : Solid block masonry using pre cast solid blocks ( Factory made) of size 40x20x10cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth for 10 cm thick wall in CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding etc complete

1.02

-

-

... More
50.6.7.2 : Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc.

70.27

-

-

... More
50.6.3.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete

4.36

-

-

... More
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

691.28

-

-

... More
50.13.1 : 9 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete

502.29

-

-

... More
5.30 : Add for plaster drip course / groove in plastered surface or moulding to R.C.C. projections.

568.98

-

-

... More
od198909/2022_2023 : "Providing and fixing fiber glass mesh of 145 GSM including cost and conveyance of all material and labor charge etc. complete. <br>"<br>

87.13

-

-

... More
od198910/2022_2023 : OD Providing water cutting to bottom edge side of slab/sunshade by 25mm wide and 15mm thick in cement mortar 1:3 including cost and conveyance of all materials, labour charges etc complete<br>

130.49

-

-

... More
9.1.1 : Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood

0.79

-

-

... More
9.5.1.1 : Providing and fixing panelled or panelled and glazed shutters for shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessery screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer - in-charge.Second class teak woodProviding and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) Second class teak wood 35 mm thick shutters

21.68

-

-

... More
9.7.1 : Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured), Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick:Second class teak wood

3.45

-

-

... More
9.7.7.1 : Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured), Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick:Float glass panes4 mm thick glass pane

16.88

-

-

... More
od198914/2022_2023 : OD Preparation of wood surface for melamine polish: Preparation of wood surface for polishing as per the follwoing procedure:. Filling the holes and screw marks in the wood surface using Wud filler and sandering the surface using 80 grade paper. Applying first coat Sanding Sealer. Fillig the Joints using Filler Powder and sandering with 120 grade paper.Aplying second coat Sanding<br>Sealer and sandering with 220 grade paper. Applying One coat melamine sealer and sandering with 320 grade paper<br>

46.92

-

-

... More
13.114 : Melamine polishing on wood work (one or more coat).

46.92

-

-

... More
9.74.3 : Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete:150x10 mm

2

-

-

... More
9.74.4 : Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete:100x10 mm

2

-

-

... More
9.76 : Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.

2

-

-

... More
9.53 : Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

52

-

-

... More
50.9.15.4 : Providing and fixing iron hooks and eyes: 150 mm

60

-

-

... More
21.1.1.3 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPolyester powder coated aluminium ( minimum thickness of polyester powder coating 50 micron )

10.08

-

-

... More
21.1.2.3 : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micorn)

12.96

-

-

... More
21.3.1 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness

1.8

-

-

... More
21.8.1 : Upto 5 mm depth and 5 mm width

12

-

-

... More
9.48.1 : Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding

583.74

-

-

... More
9.121 : Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.

23.2

-

-

... More
9.122.1 : Providing and fixing to existing door frames.30 mm thick Glas Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS : 14856, including fixing to frames.

6.72

-

-

... More
9.147F.1 : Providing and fixing factory made uPVC white colour sliding glazed door comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension uPVC extruded glazing beads, uPVC extruded interlock and uPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle with key on one side of extreme panels along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) cresent lock (if required), stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in- Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately).br Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Two track two panels sliding door made of (big series) frame 67 x 50 mm & sash 46 x 82 mm both having wall thickness of 2.3 +/- 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door above 2.00 sqm upto 5.00 sqm)

2.1

-

-

... More
9.152 : Providing and fixing steel roller for uPVC sliding door with necessary screws etc. Complete.

2

-

-

... More
11.41.2 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.

112.75

-

-

... More
11.46.2 : Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm

8.07

-

-

... More
22.5 : Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.

40.44

-

-

... More
11.37 : Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.

19.94

-

-

... More
8.31 : Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineerin-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

80.56

-

-

... More
11.48.2 : Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mm

100.5

-

-

... More
od198917/2022_2023 : OD Providing Tile beading in the edges and corners of tile work including cost conveyance labour charges etc complete.<br>

69.31

-

-

... More
8.2.2.2 : Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm

35.76

-

-

... More
8.5 : Extra for providing opening or required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.

3

-

-

... More
10.26.1 : Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.M.S. tube

482.94

-

-

... More
10.3 : Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts,locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer .

13.42

-

-

... More
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer

492.07

-

-

... More
13.80 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

1086.25

-

-

... More
13.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work

1169.06

-

-

... More
13.62.1 : Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture .

71

-

-

... More
od198918/2022_2023 : OD Providing cement mortar reaper for 1:3 supporting MP tiles over sunshade including cost and conveyance , labour charges etc. 50x25 mm<br>

412.16

-

-

... More
12.48 : Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately)

68.02

-

-

... More
12.49 : Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20 mm thickness and of approved pattern on steel frame work complete (steel frame work to be paid separately ).

6

-

-

... More
od198921/2022_2023 : Providing & laying ceramic hip end tile of approved pattern on steel frame work complete including all cost of materials, labour charges etc complete (steel frame work to be paid separately ).<br>

10

-

-

... More
2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil

49.93

-

-

... More
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

111.73

-

-

... More
60.7.1 : DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site

7.55

-

-

... More
13.7.1 : 12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)

76.25

-

-

... More
22.23.2 : Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm.

16.65

-

-

... More
22.23.1 : Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @0.70 kg per sqm

43.15

-

-

... More
22.4.1 : Providing and Placing in position suitable PVC water stops conforming to IS : 12200 for construction / expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete:Serrated with central bulb ( 225 mm wide, 8-11 mm thick)

28.04

-

-

... More
od225212/2022_2023 : Supply and fixing ductile iron heavy duty (62kg) manhole covers of size 600x600mm

4

-

-

... More
od242974/2022_2023 : Eave Board :<br>Providing and fixing Eave Board (15 cm width) as per design intent. Eave Board to be finished using 8mm thick PVC board (Thomson / Equivalent).<br>Including cost and conveyance charges of all materials, labour charges etc.

219.63

-

-

... More
od243054/2022_2023 : Jali work :<br>Providing and fixing clay jaali on frame work.Providing Jaali(Model:Indian Saphire Jally,Size:8''x8''/equivalent )using cement grout as per design<br>intent.including cost and conveyance of all materials,Labour charges etc complete.

22.69

-

-

... More
od277573/2022_2023 : CNC Cut Roof design : Providing and fixing roof design work using multiwood with CNC cut. Frame work to be finished with 18 mm thick multiwood (Make:Thomson/Equivalent).Fix 18 mm thick multiwood (Make :Thomson/Equivalent) with CNC cut design on frame work as per design. Including cost and conveyance of all materials labour charges etc. complete as per direction of Engineer-in-charge<br>

3.9

-

-

... More
10.16.1 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes

163.38

-

-

... More
od243267/2022_2023 : Applying two coats of clear coat(Cera acryl clear decorative and water repellent coating)on clay jaali work surface and including all Conveyance cost of all<br>materials and labour charges etc complete

90.74

-

-

... More
od243897/2022_2023 : PU painting:<br>Finishing the surface in the followings steps<br>1.Filling the joints and screw holes with filler Materials and sandering for even finish<br>2.Applying One coat of NC Putty<br>3.Applying One coat of PS/PU Primer<br>4.Applying one or more coat of NC White Paint<br>5.Applying one or more coat of PU Clear on NC White paint<br>Complete as per the direction of Engineer- in- Charge including all cost of accessories, labour charge etc. complete.

149.92

-

-

... More
od244883/2022_2023 : Flush Door( Laminate Finish ):<br>Providing & Fixing Plywood Door as per architect approved drawing. Door frame and shutter frameworks finished with 19 mm plywood (IS 710<br>Grade,BWP Prestige/Equivalent). Both sides of the frame to be finished 9 mm plywood with 1 mm thick laminate finish (Century laminates/equivalent)<br>using suitable adhesive (HeatX/Equivalent). Complete using necessary SS Hinges, Tower bolts, door closer , stopper, lock,handle, (SS 304<br>grade,Hafele/Hettich/equivalent) etc., Finish the doors with necessary grooves, SS strips etc. if any. Including cost and conveyance of all materials labour<br>charges etc. complete as per drawing.

6.09

-

-

... More
od244884/2022_2023 : Name board:<br>Providing and fixing name board as per design intent. Name board to be finished with 6 cm height malayalam letters as heading and remaining letters is of<br>2.5 cm height, should be engraved on 150cmx50cm/nearest titanium coated gold SS plate of 20 guage,to be fixed on existing wall using necessary fittings,<br>as per instruction of engineer in charge. Including cost and conveyance charges of all materials, labour charges etc.

1

-

-

... More
Kalari Training Centre

-

-

-

... More
2.28.1 : Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.All kinds of soil

117.61

-

-

... More
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

67.32

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

6.61

-

-

... More
4.3.1 : Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns

20.62

-

-

... More
5.33.1 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level

11.74

-

-

... More
5.33.2 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level

7.65

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

29.24

-

-

... More
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

68.15

-

-

... More
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

85.08

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

3039

-

-

... More
5.35 : Add for using extra cement in the items of design mix over and above the specified cement content therein

9.69

-

-

... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

47.1

-

-

... More
50.2.25.1 : Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge

11.37

-

-

... More
4.11 : Providing and laying damp-proof course 50 mm thick with cement concrete 1:2:4(1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).

15.57

-

-

... More
od214759/2022_2023 : Mod 4.13 Applying a coat of Inertol Poxitar Coal tar epoxy coating per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil

15.56

-

-

... More
50.6.7.1 : Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for foundation and basement including all cost of materials, labour charges etc.

1.73

-

-

... More
50.6.7.2 : Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc.

23.73

-

-

... More
50.6.3.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete

1.22

-

-

... More
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

242.62

-

-

... More
od215270/2022_2023 : Design Plastering on laterite wall using cement mortar 1:4 of 5cm thick including cost and conveyance of all materials, labour charges etc complete

10.15

-

-

... More
22.5 : Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.

31.1

-

-

... More
5.30 : Add for plaster drip course / groove in plastered surface or moulding to R.C.C. projections.

147.31

-

-

... More
od215606/2022_2023 : Providing and fixing fibre glass mesh of 145 GSM including cost and conveyance of all material and labour charge etc complete.

56.14

-

-

... More
9.121 : Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.

24.2

-

-

... More
9.122.1 : Providing and fixing to existing door frames.30 mm thick Glas Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS : 14856, including fixing to frames.

7.77

-

-

... More
od215705/2022_2023 : Preparation of wood surface for melamine polish: Preparation of wood surface for polishing as per the follwoing procedure:. Filling the holes and screw marks in the wood surface using Wud filler and sandering the surface using 80 grade paper. Applying first coat Sanding Sealer. Fillig the Joints using Filler Powder and sandering with 120 grade paper.Aplying second coat Sanding<br>Sealer and sandering with 220 grade paper. Applying One coat melamine sealer and sandering with 320 grade paper<br>

8.19

-

-

... More
13.114 : Melamine polishing on wood work (one or more coat).

8.19

-

-

... More
21.1.1.3 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPolyester powder coated aluminium ( minimum thickness of polyester powder coating 50 micron )

4.1

-

-

... More
21.1.2.3 : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micorn)

5.18

-

-

... More
21.3.1 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness

17.28

-

-

... More
21.8.1 : Upto 5 mm depth and 5 mm width

4.8

-

-

... More
9.48.1 : Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding

16.56

-

-

... More
13.62.1 : Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture .

0.72

-

-

... More
od216209/2022_2023 : Providing and laying of Laterate stone slaice of 12 inch length ,6 or 7 inch width 25mm thick laid over cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with matching pigment etc.complete as per the architectural drawings and the directions of Engineer - in -Charge.including all cost of materials, labour charges etc complete<br>

11.57

-

-

... More
11.37 : Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.

9.02

-

-

... More
8.31 : Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineerin-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

58.29

-

-

... More
od216820/2022_2023 : Providing PVC Tile beading in the edges and corners of tile work including cost conveyance labour charges etc complete.

33.6

-

-

... More
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer

242.61

-

-

... More
13.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work

242.61

-

-

... More
12.48 : Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately)

248.12

-

-

... More
12.50 : Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.

248.12

-

-

... More
od217181/2022_2023 : Providing & fixing on roof ceramic ridge tile of approved pattern on steel frmane work complete(steel frame work to be paid seperately)

39.03

-

-

... More
od217413/2022_2023 : Providing & laying ceramic hip end tile of approved pattern on steel frame work complete including all cost of materials, labour charges etc complete (steel frame work to be paid separately ).

10

-

-

... More
od218343/2022_2023 : LATERITE SLICED CLADDING -Special type red colour Exposed Laterite cladding using laticrete or equivalent gum for super structure wall including all cost of material and labour charges etc. complete .

12.72

-

-

... More
od218447/2022_2023 : Applying two coat of clear coat on laterite cladding surface and including all cost and conveyance of all materials and labour charges etc. complete.

12.72

-

-

... More
10.26.3 : Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes

11.35

-

-

... More
Gallery Steps

-

-

-

... More
2.28.1 : Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.All kinds of soil

171.11

-

-

... More
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

54.45

-

-

... More
60.7.1 : DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site

35.96

-

-

... More
7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)

10.17

-

-

... More
50.6.7.1 : Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for foundation and basement including all cost of materials, labour charges etc.

7.52

-

-

... More
50.6.7.2 : Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc.

19.01

-

-

... More
8.2.2.2 : Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm

76

-

-

... More
od218343/2022_2023 : LATERITE SLICED CLADDING -Special type red colour Exposed Laterite cladding using laticrete or equivalent gum for super structure wall including all cost of material and labour charges etc. complete .

55.08

-

-

... More
od218447/2022_2023 : Applying two coat of clear coat on laterite cladding surface and including all cost and conveyance of all materials and labour charges etc. complete.

55.08

-

-

... More
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

87.85

-

-

... More
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer

32.77

-

-

... More
13.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work

32.77

-

-

... More
Landscaping

-

-

-

... More
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

1300.06

-

-

... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

461.22

-

-

... More
Electrical Work

-

-

-

... More
1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C

70

-

-

... More
1.55.2 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group B

6

-

-

... More
1.55.3 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C

24

-

-

... More
1.11 : Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.

10

-

-

... More
1.17.3 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm

500

-

-

... More
1.17.12 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm

100

-

-

... More
1.17.30 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm

20

-

-

... More
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

400

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

120

-

-

... More
1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm

35

-

-

... More
1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch

14

-

-

... More
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch

5

-

-

... More
1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet

20

-

-

... More
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet

5

-

-

... More
1.25 : Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

4

-

-

... More
1.26 : Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

6

-

-

... More
1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)

6

-

-

... More
1.27.2 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)

5

-

-

... More
90.10.1.3 : Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )

1

-

-

... More
90.10.1.5 : Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )

1

-

-

... More
1.28.2 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module

1

-

-

... More
1.28.4 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module

1

-

-

... More
1.33 : Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.

61

-

-

... More
90.4.1 : Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.

4

-

-

... More
1.58 : Supplying and fixing PVC batten/ angle holder including connection etc. as required.

9

-

-

... More
2.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door

3

-

-

... More
2.3.4 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator16 way, Double door

1

-

-

... More
90.11.1.18 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required

1

-

-

... More
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

25

-

-

... More
2.10.3 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole

6

-

-

... More
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole

1

-

-

... More
2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

20

-

-

... More
2.14.1 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps

4

-

-

... More
2.15.1 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps

1

-

-

... More
90.14.10.3 : Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.

1

-

-

... More
od262000/2022_2023 : Supply, installation, testing and commissioning of thermoplastic polycarbonate 3Module MCBDB in accordance with IEC60529 with transparent hinged cover environment friendly, recyclable, UV resistant, halogen & silicon free, anti acid & anti corrosive enclosure having size not less than102x197x92mm as required. (Make: Hensel - Catalogue No. KV 7103 or equivalent)

2

-

-

... More
od262001/2022_2023 : Supply and fixing of thermoplastic polycarbonate cable junction box IP66/67 in accordance with IEC60529 environment friendly, recyclable, UV resistant, halogen & silicon free, anti acid & anti corrosive, shock proof with 5 pole terminals suitable to terminate up to 2.5sqmm Make: Hensel KF 0202 G or equivalent.

2

-

-

... More
od262002/2022_2023 : Supply, installation, testing and commissioning of thermoplastic polycarbonate 4Module MCBDB in accordance with IEC60529 with transparent hinged cover environment friendly, recyclable, UV resistant, halogen & silicon free, anti acid & anti corrosive enclosure having size not less than 126x228x111mm as required.(Make: Hensel - Catalogue No. KV 7104 or equivalent)

1

-

-

... More
od262003/2022_2023 : Earthing with G.I. earth pipe 2.5metre long, 40mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. With charcoal/ coke and salt as required

4

-

-

... More
od262004/2022_2023 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required.3.15 mm copper conductor ( 10 SWG )

330

-

-

... More
90.16.5.3 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.

20

-

-

... More
od262128/2022_2023 : Supply of one number PVC insulated and PVC sheathed / XLPE armoured Copper power cable of 1.1 KV grade of following sizes as required.2C 4 sqmm XLPE Cu

46

-

-

... More
od262129/2022_2023 : Supply of one number PVC insulated and PVC sheathed / XLPE armoured Copper power cable of 1.1 KV grade of following sizes as required.3C 1.5 sqmm XLPE Cu

69

-

-

... More
od262437/2022_2023 : Supply of one number PVC insulated and PVC sheathed / XLPE armoured Copper power cable of 1.1KV grade of following sizes as required.4C 4 sqmm XLPE Cu

31

-

-

... More
od262130/2022_2023 : Supply of one number PVC insulated and PVC sheathed / XLPE armoured Aluminium power cable of 1.1KV grade of following sizes as required. 2C 10 sqmm XLPE Al

43

-

-

... More
od262131/2022_2023 : Supply of one number PVC insulated and PVC sheathed / XLPE armoured Aluminium power cable of 1.1KV grade of following sizes as required.3C 10 sqmm XLPE Al

109

-

-

... More
od262132/2022_2023 : Supply of one number PVC insulated and PVC sheathed / XLPE armoured Aluminium power cable of 1.1 KV grade of following sizes as required.4C 16 sqmm XLPE Al

58

-

-

... More
od262133/2022_2023 : Supply and drawing bare earthing conductors of the following sizes along with <br>wiring / cables and giving connection as required. 25 x3 x400 mm Cu earth bench

1

-

-

... More
od262439/2022_2023 : Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required.4C 4 sqmm XLPE Cu

2

-

-

... More
od262504/2022_2023 : Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required. 2C 4 sqmm XLPE Cu

2

-

-

... More
od262440/2022_2023 : Supplying and making end termination with brass compression gland and copper lugs for following size of<br>PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required. 3C 1.5 sqmm XLPE Cu

4

-

-

... More
od262447/2022_2023 : Supply and fixing (IP68) thermoplastic polycarbonate synthetic short entry thread metric (with one piece sealing ring) with appropriate size lock nut suitable for 1.5sq mm armoured copper cable including all with appropriate size lock nut suitable for 1.5sq mm armoured copper cable including all accessories as required. Make: Hensel M25 x 1.5 or equivalent

2

-

-

... More
7.3.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.Upto 35 sq. mm

179

-

-

... More
7.7.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)

177

-

-

... More
90.6.5.11 : Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.

92

-

-

... More
9.1.2 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm)

6

-

-

... More
9.1.7 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 10 sq. mm (22mm)

4

-

-

... More
9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)

4

-

-

... More
1.41 : Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.

76

-

-

... More
90.4.3 : Conveyance installation testing and commissioning ceiling fan of all sizes using standard accessories excluding resistance type regulator wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or extending the original wiring etc. as required.

4

-

-

... More
1.50.1 : Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep

10

-

-

... More
90.4.6 : Conveyance, installation, testing and commissioning of wall mounting fans of all types using mounting brackets supplied along with the fan.

6

-

-

... More
90.4.8 : Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.

10

-

-

... More
od262505/2022_2023 : Supply of 15±2W surface mounted square LED down light fixture having polycarbonate housing, 4000K colour temperature, with minimum 100 lumen/Watt, working on 240V AC, suitable for indoor applications, including all connections etc as required. Make - Philips sleek or equivalent.

6

-

-

... More
od262506/2022_2023 : Supply of 12±2W surface mounted square LED down light fixture having polycarbonate housing, 4000K colour temperature, with minimum 100 lumen/Watt, working on 240V AC, suitable for indoor applications, including all connections etc as required. Make - Philips sleek or equivalent.

6

-

-

... More
od262507/2022_2023 : Supply, installation, testing and commissioning of 2x3W LED wall washer up and down light (IP 54) housing made of die cast aluminium and transparent tempered glass diffuser with 3000K colour temperature suitable for outdoor applications, including all connections etc. as required. Make: JAQUAR-LUPUSLWWL03X203XW or equivalent.

2

-

-

... More
od262508/2022_2023 : Supply of 20+/-2W LED tube light fitting housing made of Extruded thermal polycarbonate with 6500 K colour temperature with a lumen output minimum of 100lumen/watt, duly wired up for use on 230V AC. The fittings shall be directly on ceiling/wall, including all accessories etc. as required. Make: Wipro or equivalent.

19

-

-

... More
od262509/2022_2023 : Supply of Decorative type wall mounted LED light fixture (IP20), having opal glass with chrome finish, E27 base, 3000K colour temperature suitable for indoor applications, including all connections etc as required. 7W LED lamp suitable for the fixture is also included. Make : Jaquar KCH-CHR-MB160275541A or equivalent

2

-

-

... More
od262510/2022_2023 : Supply of following Exhaust fan in plastic frame working on 230V AC including giving connection etc. as required.250mm light duty exhaust fan. Make - Crompton or equivalent.

10

-

-

... More
od262511/2022_2023 : Supply of 450mm sweep wall fan working on 230V AC. The work shall include fixing necessary bolt and nuts making good the damages etc. as required. Make - Crompton or equivalent

6

-

-

... More
od262512/2022_2023 : Supply of ceiling fans of the following sizes using standard accessories excluding resistance type regulator as required.1200mm sweep-Single star rated ceiling fan complete with 300mm down rod, canopies, shackles and blades working on 230V/240V single phase AC. Make - Crompton or equivalent.

4

-

-

... More
od262513/2022_2023 : Supply, installation, testing and commissioning of 2.5W Step Light Fixture, having powder coated aluminium housing,3000K colour temperature, IP65 suitable for outdoor applications, including all connections etc as required. Make : Wipro Arcus or equivalent

22

-

-

... More
od262514/2022_2023 : Supply and fixing of 9W LED Bulb including all connections etc as required. Make - Jaquar or equivalent.

9

-

-

... More
od262515/2022_2023 : Supply of 15±2W suspended LED down light fixture having CRCA powder coated housing, 5700K colour temperature, with minimum 100 lumen/Watt, working on 240V AC, suitable for indoor applications, including all connections etc as required. Make - Wipro Haloplus or equivalent.

3

-

-

... More
od262516/2022_2023 : Supply of surface mounted type 34+/-2W LED light suitable for indoor application having colour temperature of 6500K, lumen output not less than 120 lumen/watts and beam angle 120 degree, CRI>80, including all connections etc as required. Make - Philips Endura next or equivalent.

10

-

-

... More
od262517/2022_2023 : Supply of 40±2W suspended 4 ft LED batten, IP40, having 5700K colour temperature and a minimum of 100 lumen/watt suitable for indoor applications, including suspension kit and all connections etc. as required. Make - Wipro Optima or equivalent.

10

-

-

... More
od262518/2022_2023 : Supply of 10±2W surface mounted LED tube light fixture having extruded aluminium/polycarbonate housing, 6500K colour temperature, with minimum 900 lumen output, working on 240V AC, suitable for indoor applications, including all connections etc as required. Make - Wipro or equivalent

5

-

-

... More
od262519/2022_2023 : Supply of 7+/-2W LED bulk head fitting (IP 65), housing made of die cast aluminium with 6500K colour temperature with a lumen output minimum 100 lumen/Watt, CRI >80, beam angle 120 degrees, suitable for outdoor applications, including all connections etc. as required. Make -Philips -Vista glow or equivalent

13

-

-

... More
od262520/2022_2023 : Supply, installation, testing and commissioning of outdoor floor mounting feeder pillar panel made of Glass Reinforced Plastic (GRP). The Degree of Ingress Protection IP 66, impact protection shall be IK10. The feeder pillar shall be comprising of the following and shall be fully wired as per latest electrical standards with hot dipped MS canopy, MS mounting frame and all necessary accessories, ready to use(Make: Cape or equivalent)Feeder pillar Incomer: 25A 10kA C Curve DP MCB-1nos,25A 30mA DPRCCB-1nos, 24 hr timer+ auto manual switch +contactor - 1 no. Out goings: 6A 10kA SP MCB - 8 nos and all <br>neccessary accessories as required.

1

-

-

... More
od262521/2022_2023 : Supply, installation, testing and commissioning of outdoor wall mounting metering panel made of thermoplastic polycarbonate enclosure. The Degree of Ingress Protection IP 65, impact protection shall be IK08. The panel shall be comprising of the following and shall be fully wired as per latest electrical standards with hot dipped MS canopy, and all necessary accessories, ready to use (Make: Cape or equivalent)Metering panel Incomer: Provision for fixing 3Phase kWH meter with control fuse and CT – 1No, 40A cut out fuse- 3 nos.Outgoings:40AFPTMMCCB16kA-1No,ELRwithCBCT-1no.(Rate for Energy meter not included in the estimate)

1

-

-

... More
od262522/2022_2023 : Supply, installation, testing and commissioning of 3 kVA, single phase input, single phase output UPS system along with necessary 12V SMF batteries for 30 minutes back up and powder coated rack including all accessories, cabling etc. as required . Make: Socomec or equivalent.

1

-

-

... More
od262523/2022_2023 : Supply and providing of first aid kit as required.

1

-

-

... More
od262524/2022_2023 : Supply and fixing framed shock treatment chart as required.

1

-

-

... More
Plumbing

-

-

-

... More
od256647/2022_2023 : Providing and fixing superior quality white vitreous china pedestal type water closet (European type) with seat and lid, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid HINDWARE or Equivalent <br>approved municipal design complete, including painting of fittings and brackets, cutting and making <br>good the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid

8

-

-

... More
17.4.1 : Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required:One urinal basin with 5 litre white P.V.C. automatic flushing cistern

3

-

-

... More
od256651/2022_2023 : Providing and fixing (579 CHR) HEALTH FAUCET of Superior quality Jaguar or equivalent brand

8

-

-

... More
od256653/2022_2023 : Providing and fixing Cavier SS towel rod (60 cm) complete with brackets and CP brass screws with concealed fitting arrangement of approved quality and colour. JAQUAR ACN-1111SM or Equivalent

12

-

-

... More
od256656/2022_2023 : Providing and fixing superior quality brand CP Soap Dish Holder concealed fitting<br>arrangements, weighing not less than 106 gms (Make: Jaguar)

14

-

-

... More
od256664/2022_2023 : Providing and fixing (089 ALD c) stop cock of superior quality 15 mm nominal bore Jaguar or equivalent brand<br>

18

-

-

... More
od256665/2022_2023 : "Providing and fixing C.P. brass bib cock of superior quality Jaguar or equivalent brand<br>conforming to IS:8931. 15 mm nominal bore"<br>

15

-

-

... More
od256667/2022_2023 : Providing and fixing CHR O. Head shower of superior quality Jaguar or equivalent brand.<br>

8

-

-

... More
od256670/2022_2023 : Providing and fixing (UN0002) Universal Angle Cock of superior quality Jaguar or equivalent<br>

26

-

-

... More
od256671/2022_2023 : Providing and fixing Towel Rack SS 24" M-Brand of approved quality and<br>

12

-

-

... More
od257902/2022_2023 : Supply & Fixing square Cockroach proof Traps with CP Gratings. Unloading materials supplied at site and storing it in safe place provided in the site. (Make: ACO/SGS )

15

-

-

... More
od258139/2022_2023 : Providing and fixing superior quality White Vitreous China Wash basin size 630x450mm with a pair of 15 mm C. P. brass pillar taps with C.I. brackets, 32 mm waste pipe of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required ect. complete: JAQUAR ARS-WHT-39803 or Equivalent<br>"<br>

7

-

-

... More
18.7.2 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall20 mm nominal outer dia pipes

150

-

-

... More
18.7.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall25 mm nominal outer dia pipes

150

-

-

... More
18.8.2 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.20 mm nominal outer dia pipes

150

-

-

... More
18.8.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.25 mm nominal outer dia pipes

150

-

-

... More
18.9.2 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work20 mm nominal outer dia pipes

150

-

-

... More
18.9.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work25 mm nominal outer dia pipes

150

-

-

... More
18.51.1 : Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore

15

-

-

... More
50.18.7.2.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge 20 mm dia 10 Kgf/cm2- Internal work - Exposed on wall

100

-

-

... More
50.18.7.3.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 10Kgf/ cm2- Internal work- Exposed on wall

100

-

-

... More
50.18.7.4.2 : Providing and fixing PVC, pipes fittings including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 6 Kgf/cm2 - internal work- Exposed on wall

100

-

-

... More
50.18.7.6.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 6 Kgf/cm2 - Internal work- Exposed on wall

100

-

-

... More
50.18.9.9.2 : Providing and fixing PVC pipes includes joints of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in CHarge. 110 mm dia 4 Kg/cm2

100

-

-

... More
18.48 : Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

2100

-

-

... More
Pond Conservation

-

-

-

... More
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

54.48

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

3.12

-

-

... More
60.7.1 : DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site

42.23

-

-

... More
5.2.2 : Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)

1.41

-

-

... More
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

5.91

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

916.5

-

-

... More
4.2.3 : Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

26.89

-

-

... More
50.6.7.2 : Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc.

71.57

-

-

... More
7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)

138.63

-

-

... More
od256679/2022_2023 : special type exposed laterite masonry with neatly dressed laterite stone of size 30x20x20 cm or nearest size in cement mortar 1:6 for superstructure above plinth level upto floor two level including all cost and conveyance labour charges etc complete

2.47

-

-

... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

881.21

-

-

... More
11.20.1 : Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand).Light shade pigment using white cement

134.08

-

-

... More
13.48.2 : Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.75 ltr/10 sqm of approved brand and manufacture

46.94

-

-

... More
9.48.1 : Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding

45

-

-

... More
13.52.1 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work

1.8

-

-

... More
10.26.1 : Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.M.S. tube

856.8

-

-

... More
External lighting

-

-

-

... More
od275973/2022_2023 : SITC of Solar LED lighting System with following accessories. (a) All in one Solar 40W LED having 60W solar module Wp with 24 Ah battery having 5000 lumens approximate weight of 19 Kg suitable to fit on tubular pole. (b) Pole :- 4 Mtr. long (Weight -95-100kg) armless pole of cast iron with bottom dia.200mm with base plate and top dia. 75 mm, foundation bolt etc. complete fixed on existing cement concrete foundation etc. as per the directions of engineer at site as required

6

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.