Kerala Irrigation Infrastructure Development Corporation Limited Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kerala Irrigation Infrastructure Development Corporation Limited - KIIDC Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date27 Aug 2024
Closing Date11 Sep 2024
Tender Amount₹ 3,27,25,631 
Notes
Download

Costs

Summary

General-government Guest House Aluva Renovation And Upgradation Of Main Block General Civil Work

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
15.40.1:Dismantling precast concrete or stone slabs in walls, partition walls etc. including stacking within 50 metres lead:Thickness upto 40 mm

34.96

-

-

... More
15.23.1:Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm

2358.77

-

-

... More
15.31:Dismantling tiled roofing with battens, boarding etc. complete including stacking of serviceable material and disposal of unserviceable material within 50 metres lead.

600.45

-

-

... More
15.57:Dismantling aluminium / Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 metres lead as directed by Engineer - in-Charge

55.29

-

-

... More
15.14.1:Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead:Of sectional area 40 square centimetres and above

143.62

-

-

... More
OD15873/2024-2025:Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 meters lead: complete as per direction of Engineer-in-Charge.With SURKHI MORTARS

3558.01

-

-

... More
2.28.1:Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.All kinds of soil

678.68

-

-

... More
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

26.42

-

-

... More
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

22.01

-

-

... More
5.33.1:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level

21.71

-

-

... More
5.33.2:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level

33.08

-

-

... More
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

18.66

-

-

... More
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

99.27

-

-

... More
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

89.65

-

-

... More
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

77.09

-

-

... More
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

15.6

-

-

... More
5.9.16.1:Centering and shuttering including strutting, etc. and removal of form for: Edges of slabs and breaks in floors and wallsUnder 20 cm wide

81.9

-

-

... More
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

6574.92

-

-

... More
2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

55.62

-

-

... More
50.2.25.1:Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge

17.65

-

-

... More
50.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.

88.32

-

-

... More
50.6.3.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete

32.25

-

-

... More
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

944.02

-

-

... More
OD12092/2024-2025:Applying Anti termite treatment on the flooring using second-generation chemicals which is ecofriendly and nil harmful of human beings and pet animals which control the pests including all cost and labour charges etc complete

1967.14

-

-

... More
OD12118/2024-2025:Supplying and fixing of traditional brass latch and lock

75

-

-

... More
9.5.1.1:Providing and fixing panelled or panelled and glazed shutters for shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessery screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer - in-charge. Second class teak wood35 mm thick shutters

30.68

-

-

... More
9.7.1:Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured), Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick:Second class teak wood

83.58

-

-

... More
12.1.1:Providing corrugate G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete ( up to any pitch in horizontal / vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.1.00 mm thick with zinc coating not less than 275 gm/m2

1128.02

-

-

... More
14.72:Providing and fixing double scaffolding system (cup lock type) on the exterior side, upto seven story hight made with 40 mm dia. M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staricase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required location with essential safety features for the workmen etc. complete as per directions and approval of Engineer- in Charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. Note:- This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done .

3343.47

-

-

... More
14.46:Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.

278.31

-

-

... More
21.17:Providing and fixing anodised aluminium grill ( anodised transparent or dyed to required shade according to IS : 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P brass/stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge.(Only weight of grill to be measured for payment ).

21.24

-

-

... More
10.2:Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

2021.61

-

-

... More
10.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover

9.24

-

-

... More
9.90.2:Providing and fixing special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete.Size 50 mm

65

-

-

... More
10.16.1:Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes

1053.62

-

-

... More
OD13008/2024-2025:Supplying and fixing G I Mesh and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

31

-

-

... More
50.9.13.1:Supplying and fixing Anjily wood wrought and put up for roof members including cost and conveyance of materials etc. complete .

19.05

-

-

... More
OD13006/2024-2025:Supply and fixing Heat barrier aluminium sheet double sided (HG-7L-FR-100) fixing in between roofing sheets with perfect water tight and roofing sheet as per approved quality etc. cost of all materials, conveyance and unloading of all materials, all as per standard specifications and as per the instructions of the Engineer-in-charge. (All materials are approved by Architect before execution)

1542.18

-

-

... More
OD13005/2024-2025:Supplying and fixingRain water gutter ALUMINIUM POWDER COATED including all materials and labour charges etc complete

292

-

-

... More
OD13359/2024-2025:Providing and fixing well seasoned and knot free first class teak wood frames fixed in position of false ceiling such as rafters,Purlins, ridge, wall plate,Collar, collar pin etc. complete at all levels as directed by the Engineer in Charge. Applying antitermite treatment after cleaning the exposed surface of wood. including cost and conveyance of all materials, labour for ornamental cutting, steps,bedding etc. wherever necessary, scaffolding charges etc complete. and as directed by Engineer-in-charge.

1476.42

-

-

... More
OD13054/2024-2025:Supplying and fixing Reuse wood work in frames ,purlins and rafters etc. complete at all levels including all materials and labour charges etc complete as directed by the Engineer in Charge.

361.6

-

-

... More
OD13092/2024-2025:Applying aquacoat PU Glossy Clear wood or equalent work with two coats after preparing base rubbing and cleaning emery paper, filling holes and finishing the surface with ceiler including all cost and labour charges etc. complete

2001.53

-

-

... More
12.48:Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately)

470.2

-

-

... More
OD13132/2024-2025:Providing & fixing on Reuse roof mangalore tile of approved size and as per approved pattern on wood frame work complete (wood frame work to be paid seperately)

131.25

-

-

... More
12.49:Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20 mm thickness and of approved pattern on steel frame work complete (steel frame work to be paid separately ).

136.4

-

-

... More
OD13134/2024-2025:Providing & fixing on roof Fish tile of approved size and as per approved pattern on wood frame work complete (wood frame work to be paid seperately)

342.83

-

-

... More
OD13135/2024-2025:Providing & fixing on roof Reuse fish tile of approved size and as per approved pattern on wood frame work complete (wood frame work to be paid seperately)

342.83

-

-

... More
OD13136/2024-2025:Repair and replacing damaged timber balustrades wooden work including all materials labour charge etc complete

50

-

-

... More
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer

4445.99

-

-

... More
OD13145/2024-2025:Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete

3464.31

-

-

... More
13.48.1:Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm

5688.07

-

-

... More
8.1.1.2:Marble work gang saw cut (polished and machine cut) of thickness 18 mm for wall lining ( veneer work), backing filled with a grout of 12 mm thick average in cement mortar 1:3 ( 1 cement : 3 coarse sand), including pointing with white cement mortar 1:2 ( 1 white cement : 2 marble dust) with an admixture of pigment to match the marble shade ( To be secured to the backing by means of cramps, which shall be paid for separately).Area of slab over 0.50 sqm

131.5

-

-

... More
11.39:Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS: 15622, of approved make in colours White, Ivory, Grey, fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 Coarse sand), including grouting the joints with white cement and matching pigments etc., complete.

268.81

-

-

... More
11.36:Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

650.19

-

-

... More
11.41.2:Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.

1243.96

-

-

... More
8.2.2.2:Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm

24.49

-

-

... More
OD13177/2024-2025:Supply and installationof PVC vinyl flooring.

62.25

-

-

... More
OD13184/2024-2025:Supply and installation of teak Timber wooden flooring using 18mm thick wood planks in flooring, planks to be fixed on plywood base using suitable adhesive and nails. Including cost and conveyance, labour charges etc complete.<br>

431.41

-

-

... More
22.5:Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.

498.63

-

-

... More
OD13187/2024-2025:Providing and laying border tile 150x200mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colour such as White, Ivory, Grey, Fume Red Brown, laid on 20mm thick cement motar 1:4 ( 1 cement : 4 coarse sand), including pointing the joints with white cement and matching pigment etc., complete

48.14

-

-

... More
OD13206/2024-2025:Supplying and laying Coble stone in landscape area of 150mm thick including all cost of materials, labour etc. complete as per the direction of Engineer in Charge.

75.31

-

-

... More
OD13207/2024-2025:Screed Concrete Providing and laying 1:3:6 using 4 to 10 cm thickness with cement plaster 6mm and 20 mm metal ( 60% 20 mm metal and 6mm metal 40% ) down graded hard granite broken stone floated hard and levells trowelled smooth having necessary slope and M-sand including cost and conveyance of all material, labour charges, hire, providing neccessary grid line as per engineer in charge curing etc complete including cement .

213.15

-

-

... More
OD13213/2024-2025:Supply and installation of wodden laminate flooring ( green panel wood )using 18mm thick wood planks in flooring, planks to be fixed on plywood base using suitable adhesive and nails. Including cost and conveyance. Labour charges etc complete.<br>

490.26

-

-

... More
13.44.1:Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm)

3031.42

-

-

... More
11.46.2:Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm

31.66

-

-

... More
OD13338/2024-2025:Providing and laying Restile trendy smooth Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorbtion less than 0.08% and conforming to I.S 15622 of approved make, in all colours & shade, in skirting, riser of steps, over 12mm thick bed of cement motar 1:3 (1 cement :3 coarse sand), including grouting the joint with white cement & matching pigments ets. complete.<br>size of tile 600x600 mm

37.43

-

-

... More
OD13372/2024-2025:Providing and laying Restile trendy smooth Vitrified tiles or equivalent make approved by architect indifferent sizes (thickness to be specified by manufacturer), with water absorbtion less than 0.08% and conforming to I.S 15622 of approved make, in all colours & shade, in skirting, riser of steps, over 20mm thick cement motar 1:4 (1 cement :4 coarse sand), including grouting the joint with white cement & matching pigments ets. complete.<br>size of tile 600x600 mm

5.35

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.