Kerala Irrigation Infrastructure Development Corporation Limited Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kerala Irrigation Infrastructure Development Corporation Limited - KIIDC Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date19 Jul 2023
Closing Date8 Aug 2023
Tender Amount₹ 24,73,05,996 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
OD11619/2023-2024:Bailing out water Using 5HP Pump- Bailing out water with 5HP engine and pump set including conveyance to site and erection,cost of fuel, lubrication oil and other stores, including all operation cost etc complete

3000

-

-

... More
OD11620/2023-2024: BAILING OUT WATER USING PUMP ABOVE 10HP AND UP TO 20HP - Bailing out water with engine and pump set above 10HP and up to 20HP, including conveyance to site and erection,cost of fuel, lubrication oil and other stores, including all operation cost etc complete

1000

-

-

... More
OD11621/2023-2024:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means<br>over areas exceeding 30 cm in depth, including disposal of excavated earth, with all lead and lift, disposed<br>earth to be levelled and neatly dressed and as directed by Engineer in charge.All kinds of soil<br>

6290.15

-

-

... More
3.13.4.A:Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, backfilling the excavation earth to the extent required and utilising the remaining earth locally for road work <br> Hard Rock ( blasting prohibited ) - Mechanical Means<br>

91.84

-

-

... More
OD11657/2023-2024:DOWEL BARS - Supplying and Providing MS dowel bars of size 25 mm dia of 3.0m long<br>(1.5m in rock and 1.5m in concrete ) including drilling holes of 30mm dia and filling the gap with<br>cement grout( 0.50kg/each) etc complete

376

-

-

... More
OD12232/2023-2024:Bored cast-in-situ M30 grade R.C.C. Pile Using Batching Plant, Transit Mixer and Concrete Pump excluding Reinforcement complete as per Drawing and Technical Specifications and removal of excavated earth with all lifts and lead upto 1000 m. Pile diameter-1000 mm

210

-

-

... More
OD12231/2023-2024:Boring providing and installing bored cast in situ reinforced cement concrete piles of M30 grade of specified diameters and length into hard rock,to carry a safe working load not less than specified excluding the cost of steel reinforcement but including the cost of boring ,with bentonite solution including removal of excluded earth with all lifts and leads-1000 mm diameter piles

56

-

-

... More
12.22:Providing Steel Liner 10mm thick for Curbs and 6 mm thick for Steining of Wells including Fabricating and Setting out as per Detailed Drawing.

12.42

-

-

... More
12.38.B.2:Cement Concrete for Reinforced Concrete in Pile Cap complete as per Drawing and Technical Specification R C C Grade M-25 - Using Batching Plant, Transit Mixer and Concrete Pump

173.09

-

-

... More
12.8.B.1:Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications <br> PCC Grade M20<br>

1858.7

-

-

... More
13.5.E.P.1:Plain/Reinforced cement concrete in sub-structure complete as per drawing and Technical Specifications RCC Grade M20 - Using concrete Mixer - Height upto 5m

765.1

-

-

... More
13.5.E.q.1:Plain/Reinforced cement concrete in sub-structure complete as per drawing and Technical Specifications RCC Grade M20 - Using concrete Mixer - Height 5m to 10 m

438.29

-

-

... More
12.8.E.2.1:Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications. <br> RCC Grade M25 - With Batching Plant, Transit Mixer and Concrete Pump <br>

25.8

-

-

... More
13.5.F.P.2:Plain/Reinforced cement concrete in sub-structure complete as per drawing and Technical Specifications RCC Grade M25 - With Batching Plant, Transit Mixer and Concrete Pump - Height upto 5m

108.97

-

-

... More
13.5.F.q.2:Plain/Reinforced cement concrete in sub-structure complete as per drawing and Technical Specifications RCC Grade M25 - With Batching Plant, Transit Mixer and Concrete Pump - Height 5m to 10m

212.26

-

-

... More
12.8.A.1:Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications. <br> PCC Grade M15 <br>

1662.99

-

-

... More
OD12226/2023-2024:Providing hot rolled Z steel sheet pile EN 10248 of size 700x420x8.5mm or nearest available size driving down vertically in lines and levels interlocking with adjacent piles with suitable pile driving unit and all accessories including all labour hire charge etc. complete and as per the directions of departmental officers at site (Item to be pre measured)

186877.6

-

-

... More
OD11671/2023-2024:Providing & making Gabion structure with Mechanically Woven Double Twisted Hexagonal Shaped Wire mesh Gabion Boxes as per IS 16014:2012,MORTH Clause 2500, of required size, Mesh Type 10x12(D=100 mm with tolerance of ± 2%) Zinic+PVC coated, Mesh wire diameter2.7/3.7mm, mechanically edged/selvedged with partitions at every 1m interval and shall have minimum 10 numbers of openings per meter of mesh perpendicular to twist, tying with lacing wire of diameter 2.2/3.2mm(ID/OD), supplied @3% by weight of Gabion boxes, filled with boulders with least dimension of 200 mm, as per drawing, all complete as per directions of Engineer-in-charge.

660

-

-

... More
12.40:Supply, Fitting and Placing un- coated HYSD bar Reinforcement in Foundation complete as per Drawing and Technical Specifications

231.08

-

-

... More
13.6:Supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and Technical Specifications

96.84

-

-

... More
14.2:Supplying, fitting and placing HYSD bar reinforcement in super-structure complete as per drawing and technical specifications

65.06

-

-

... More
OD11675/2023-2024:Providing and laying in position cement concrete of specified gradeICLUDIG the cost of centering and shuttering - All work up to plinth level: 1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

66

-

-

... More
OD11678/2023-2024:Providing and fixing 100 mm diameter and 60 cm long rain water spout in cement mortar<br>1:4 (1 cement : 4 fine sand).<br>Stone ware spout

88

-

-

... More
OD11679/2023-2024:Finishing with Epoxy paint (two or more coats) at all locations prepared and<br>applied as per manufacturer's specifications including appropriate priming<br>coat, preparation of surface, etc. complete.On concrete work

1384.33

-

-

... More
Appendix B- Side Protection Works of river

-

-

-

... More
OD11731/2023-2024:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means<br>over areas exceeding 30 cm in depth, including disposal of excavated earth, with all lead and lift, disposed<br>earth to be levelled and neatly dressed and as directed by Engineer in charge.All kinds of soil<br>

14018

-

-

... More
OD11737/2023-2024:RING BUND Type II Putting up ring bund with earth fille gunny bags of top width 1.0m bottom width 2.0m height 2.0 m side and filling in between with earth to form ring bund and maintaining the same leak proof till the completion of the work and clearing the site by dismantling the bund after completion of the work.etc.complete.

250

-

-

... More
OD11738/2023-2024:Bailing out water Using 5HP Pump- Bailing out water with 5HP engine and pump set including conveyance to site and erection,cost of fuel, lubrication oil and other stores, pay of staff etc complete

2000

-

-

... More
12.8.G.2.1:Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications. RCC Grade M30 - Using Batching Plant, Transit Mixer and Concrete Pump

818

-

-

... More
12.40:Supply, Fitting and Placing un- coated HYSD bar Reinforcement in Foundation complete as per Drawing and Technical Specifications

81.8

-

-

... More
13.5.G.p.2:Plain/Reinforced cement concrete in sub-structure complete as per drawing and Technical Specifications RCC Grade M30 - Height upto 5m - using Batching Plant, Transit Mixer and Concrete Pump

589.8

-

-

... More
13.6:Supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and Technical Specifications

124.82

-

-

... More
OD11812/2023-2024:Plain/Reinforced cement concrete in sub-structure complete as per drawing and Technical Specifications RCC Grade M30 - With Batching Plant, Transit Mixer and Concrete Pump - Height 5m to 10m

51.48

-

-

... More
14.2:Supplying, fitting and placing HYSD bar reinforcement in super-structure complete as per drawing and technical specifications

12.36

-

-

... More
OD11742/2023-2024:PVC WEEP HOLES- Providing weep holes using 75mm dia. PVC pipes working pressure 4kg /sq.cm including cost of materials, conveyance, labour charges etc. complete.

1214.2

-

-

... More
OD11744/2023-2024: Conveyance and dumping of departmental granite stones-Conveyance of departmental granite stone 20 to 45 dm3 in size from stack at site and dumping in position (60% 45m3,30%30 to 40dm3 and 10% 20 to 30dm3 stones) to lines and levels to from the core l as per approved design including all leads and lifts etc. complete as per the direction of the departmental officers at site.

1050

-

-

... More
OD11745/2023-2024:Supplying and stacking granite stone 20 to 45 dm3 for dumping works- Supplying at site of work granite stone 20 to 45 dm3 in size (60% 45m3,30%30 to 40dm3 and 10% 20 to 30dm3 stones) for measurement ( deducting not less than 15% for voids as fixed by the departmental officer at site) including all cost, conveyance, loading and unloading charges all other incidental charges all leads and lifts etc. complete as per the direction of the departmental officers at site

1050

-

-

... More
OD11746/2023-2024:Providing & making Gabion structure with Mechanically Woven Double Twisted Hexagonal Shaped Wire mesh Gabion Boxes as per IS 16014:2012,MORTH Clause 2500, of required size, Mesh Type 10x12(D=100 mm with tolerance of ± 2%) Zinic+PVC coated, Mesh wire diameter2.7/3.7mm, mechanically edged/selvedged with partitions at every 1m interval and shall have minimum 10 numbers of openings per meter of mesh perpendicular to twist, tying with lacing wire of diameter 2.2/3.2mm(ID/OD), supplied @3% by weight of Gabion boxes, filled with boulders with least dimension of 200 mm, as per drawing, all complete as per directions of Engineer-in-charge.

750

-

-

... More
OD11747/2023-2024:Providing and laying filter material underneath pitching etc complete as per drawing and technical specification

1474.08

-

-

... More
OD11750/2023-2024:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:<br>1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

375.6

-

-

... More
Appendix C- Construction of Approach Road

-

-

-

... More
2.1.2:Cutting of trees, including cutting of trunks, branches and removal of stumps, roots, stacking of serviceable material with all lifts and up to a lead of 1000 metres and earth filling in the depression/pit. <br> Girth from 600 mm to 900 mm

6

-

-

... More
2.3.2.A:Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness <br> In area of light jungle - By Mechanical Means<br>

0.08

-

-

... More
3.18:Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2

285

-

-

... More
4.9.B.3.A:Providing, laying, spreading and compacting stone aggregates of specific sizes to water-bound macadam specification including spreading in a uniform thickness, hand packing, rolling with 3 wheeled steel/ vibratory roller 8-10 tonnes in stages to the proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density Grading-II - Using Screening Crushable types such as Moorum or Gravel- By Mechanical Means

29.07

-

-

... More
4.9.B.2.A:Providing, laying, spreading and compacting stone aggregates of specific sizes to water-bound macadam specification including spreading in a uniform thickness, hand packing, rolling with 3 wheeled steel/ vibratory roller 8-10 tonnes in stages to the proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density Grading-I - Using Screening Crushable types such as Moorum or Gravel - By Mechanical Means

27.36

-

-

... More
5.1.a:Providing and applying primer coat with bitumen emulsion ( SS) on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.70 - 1.0 kg/sqm using mechanical means.

364.8

-

-

... More
5.2.a:Providing and applying tack coat with bitumen emulsion( RS) using emulsion pressure distributor at the rate of 0.20 - 0.30 kg per sqm on the prepared bituminous surface cleaned with mechanical broom.

364.8

-

-

... More
5.7.2:Providing, laying and rolling of close-graded premix surfacing material of 20 mm thickness composed of 13.2 mm to 0.09 mm (Type-B) aggregates using viscosity grade bitumen ( VG - 30) to the required line, grade, and level to serve as wearing course on a previously prepared base, including mixing in a suitable HMP of appropriate capacity not less than 75 tonnes/hour., laying and rolling with a Smooth wheeled roller 8-10 tonne capacity, and finishing to the required level and grade.

342

-

-

... More
5.10.2.a:Providing and laying of premix sand seal coat with HMP of appropriate capacity not less than 75 tonnes/ hours using crushed stone chipping 6.7 mm size and bitumen (VG-30) 6.8 kg per 10 sqm

342

-

-

... More
3.24.A:Construction of unlined surface drains of average cross sectional area 0.40 sqm in soil by mechanical Means to specified lines, grades, levels and dimensions to the requirement of clause 301 and 309. Excavated material to be used in embankment within a lead of 50 metres (average lead 25 metres)<br>

228

-

-

... More
Appendix - D Construction of Generator Room

-

-

-

... More
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

33.72

-

-

... More
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

120

-

-

... More
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

6.44

-

-

... More
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

19.2

-

-

... More
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

76.79

-

-

... More
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

35.76

-

-

... More
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

70.87

-

-

... More
50.5.33.1:Providing and laying in position machine batched and machine mixed design mix M- 20 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. Note: Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately. All work up to plinth level

7.45

-

-

... More
50.5.33.2:Providing and laying in position machine batched and machine mixed design mix M-20 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. Note:- Cement content considered in this item is @ 330 kg/cum. Excess or less cement used as per design mix is payable or recoverable separately. All work above plinth level upto floor V level

10.51

-

-

... More
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

894.48

-

-

... More
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)

15.66

-

-

... More
13.33.1:Pointing on stone work with cement mortar 1:3 ( 1 cement : 3 fine sand):Flush/ Ruled pointing

6.96

-

-

... More
50.6.2.1:Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15 cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15cm in: CM 1:6 ( 1 cement :6 coarse sand) etc complete

30.61

-

-

... More
50.9.1.1:Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood

0.14

-

-

... More
14.29:Providing and fixing M.S. round or squre bars with M.S. flats at required spacing in wooden frames of windows and clerestory windows.

35.24

-

-

... More
9.48.1:Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding

154.8

-

-

... More
50.9.2.1:Providing and fixing paneled and glazed shutters for doors, windows and clerestory windows, 35 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineerin - charge using Anjili/ Jack wood

4.03

-

-

... More
9.97.3:Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:200x10 mm

2

-

-

... More
9.100.2:Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:100 mm

2

-

-

... More
9.103:Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS: 1868) aluminium lever handles of approved quality with necessary screws etc . complete.

1

-

-

... More
50.9.15.1:Supplying and fixing 200 mm Aluminium aldrop

1

-

-

... More
50.9.15.3:Providing and fixing iron hooks and eyes : 200mm.

5

-

-

... More
50.9.15.5:Providing and fixing iron hooks and eyes: 100 mm

10

-

-

... More
9.117.1:Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1 mm), with wall thickness 2.0mm (±0.2 mm), corners of the door frame to be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 x 19 mm and 1 mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer's specification and direction of Engineer-in-chargeExtruded section profile size 48x40 mm

5.1

-

-

... More
9.120.1:Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and sized of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC 'C' channel of size 30 mm thickness, 70 mm width out of whicj 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5mm thick, 95 mm wide PVC sheet out of which75 mm shall be tapered in 45 degree on th inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mmx2) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail. paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded /sealed to the styles & rails with 7 mm (5 mm + 2 mm ) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive etc. complete as per direction of Engineer -in-charge, manufacture's specification & drawing.30 mm thick plain PVC door shutters

1.89

-

-

... More
10.6.2:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.20 mm M.S. laths with 1.20 mm thick top cover

3.15

-

-

... More
13.4.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand)

320.12

-

-

... More
13.16.1:6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)

69.24

-

-

... More
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer

379.32

-

-

... More
13.46.1:Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

111.72

-

-

... More
13.48.3:Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture

17.27

-

-

... More
13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work

389.36

-

-

... More
13.62.1:Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture .

8.78

-

-

... More
11.38:Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of Ist quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 Coarse sand), including pointing the joints with white cement and matching pigments etc., complete.

17.05

-

-

... More
17.3.1:Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid

1

-

-

... More
17.7.3:Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps

1

-

-

... More
50.18.7.4.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10Kgf/cm2- Internal work - Exposed on wall

50

-

-

... More
50.18.9.22.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend

2

-

-

... More
50.18.8.9.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2

20

-

-

... More
18.48:Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

1000

-

-

... More
51.19.ST1:Supplying and installing ready made PVC Septic tank including the cost of carriage, trenching, placing at the level below ground level as specified as per the direction of engineer in charge (Provision for CC/RCC/Sand/06mm aggregate for the preparation of bed shall be paid separately)<br> 1. Below 15 flush capacity

1

-

-

... More
OD11895/2023-2024:Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622<br>(thickness to be specified by the manufacturer), of approved make, in all colours,<br>shades except burgundy, bottle green, black of any size as approved by Engineerin-<br>Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement<br>mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @<br>3.3kg per sqm, including pointing in white cement mixed with pigment of<br>matching shade complete. Details of cost for 1 sqm<br>MATERIAL<br>Ceramic Glazed tiles = 1.000 sqm<br>Add for wastage & breakage @ 2.5 %<br>= 0.025 sqm<br>Total = 1.025 sqm

12.24

-

-

... More
17.73.1:Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm. weighing not less than 170 gms

1

-

-

... More
17.71:Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms

1

-

-

... More
OD11911/2023-2024:providing and laying antiskid ceramic floor tiles 300x300x7 mm of 1st quality conforming to IS 15622 of approved make ,shade and pattern laid on 20mm thick cement mortar 1:4 (1 cement :4 coarse sand ) and jointed with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc .including cost and conveyance of all materials ,labour charges,lead ,lift etc ,complete as directed by the Engineer in charge at all levels<br>details of cost for 1 sqm<br>MATERIAL<br>Glazed ceramic floor tiles 300 x 300 mm size = 1.00 sqm<br>Add for wastage & breakage @ 2.5% = 0.025 sqm<br>Total = 1.025 sqm

2.8

-

-

... More
9.53:Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

14

-

-

... More
10.5.1:Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces

2.1

-

-

... More
5.22A.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more

1260.96

-

-

... More
Appendix E - Electrical works

-

-

-

... More
90.11.1.10:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)

2

-

-

... More
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

15

-

-

... More
2.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole

10

-

-

... More
2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

10

-

-

... More
2.25:Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for tripple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.

2

-

-

... More
2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

1

-

-

... More
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

1

-

-

... More
90.12.7.40:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp

400

-

-

... More
90.12.7.28:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp

50

-

-

... More
90.12.7.30:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 70 sq mm

50

-

-

... More
9.1.21:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm)

8

-

-

... More
9.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)

20

-

-

... More
9.1.23:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)

4

-

-

... More
4.1.2:Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness

75

-

-

... More
4.1.3:Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.225 mm width X 50 mm depth X 1.6 mm thickness

75

-

-

... More
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

6

-

-

... More
5.3:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.

5

-

-

... More
5.13:Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.

50

-

-

... More
5.14:Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.

300

-

-

... More
5.15:Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

100

-

-

... More
5.17:Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.

30

-

-

... More
1.8.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C

20

-

-

... More
1.55.1:Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group A

15

-

-

... More
OD12009/2023-2024:Supply and providing 9 Litre capacity GI Fire Bucket painted in post office red with primer coat of red oxide and written with white paint 'FIRE' mounted on MS angle frame work/ wall bracket filled with fine sand, painting the bracket/ floor stand including making good the damages, colour washing etc. as required

2

-

-

... More
OD12010/2023-2024:Supply and providing 2.5mm thick, 11KV grade, synthetic elastometric fire retardant insulating sheet

2

-

-

... More
1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C

14

-

-

... More
1.12:Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.

10

-

-

... More
1.14.1:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire

100

-

-

... More
1.14.2:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

100

-

-

... More
1.14.3:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire

50

-

-

... More
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

50

-

-

... More
1.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm

30

-

-

... More
1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

2

-

-

... More
1.26:Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

10

-

-

... More
1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)

6

-

-

... More
1.27.3:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm)

4

-

-

... More
1.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)

4

-

-

... More
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch

5

-

-

... More
1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch

2

-

-

... More
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet

5

-

-

... More
1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet

2

-

-

... More
1.24.6:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet

1

-

-

... More
1.28.2:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module

6

-

-

... More
1.28.3:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.4 Module

4

-

-

... More
1.28.4:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module

4

-

-

... More
1.41:Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.

25

-

-

... More
1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.

4

-

-

... More
1.44:Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.

2

-

-

... More
1.50.1:Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep

2

-

-

... More
90.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)

1

-

-

... More
1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).

2

-

-

... More
1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required.

3

-

-

... More
OD12040/2023-2024:Supply, installation, testing and commissioning of Rechargeable Emergency Inverter LED Bulb 9 -Watt

3

-

-

... More
90.3.19.3:Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required1200 mm 1X20W LED Lamp with box type fixture

8

-

-

... More
OD12043/2023-2024:Supply of 450mm sweep wall fan on surface including mouting and providing all accessories required for complete installation, testing, commisioning etc as required complete (Havells Airboll Hi-Speed or equivalent)<br>

2

-

-

... More
OD12044/2023-2024:Supply of ceiling fan of 1200mm sweep, including the down rod of standard length (upto 30 cm.) of (havels make, ES 50 Premium White or CG make, Riveria or equivalent).<br>

4

-

-

... More
OD12045/2023-2024:"Supply of LED medium-bay type luminaire with a system power of 100 W, system efficacy >125 lm/W, and system light output greater than 13500 lumens. The luminaire shall have a rated life of 50000 burning hours as per L70B50 criteria. Ther luminaire housing shall be made of diecast aluminium and high transmittance tempered glass with PC lens. The luminaire must be able to operate from -10 deg C to 45 deg C The luminaire must meet IP66, IK08 rating with THD < 10%, PF > 0.95,with auto high cut off @ 325 ± 15V & Auto Restart, 4 kV inbuilt surge protection. The luminaire must have phase to phase protection of 440 V upto 8 hours atleast. The luminaire must be CRI>80, SDCM < 5 and a wide beam angle of 110 deg. The luminaier shall have Class I protection and must be BIS certified and must have LM79 & LM80 reports from NABL accredited labs.<br>Make : Philips BY225P LED135S CW WB PSU or equivalent"<br>

2

-

-

... More
OD12046/2023-2024:Supply of LED bulkhead luminaire that fits seamlessly in a variety of applicatications, consuming a power of 6 W , lumen output greater than 700 lumens with a system efficacy > 110 lm/W. The luminaire shall housing shall be made of High Pressure diecast aluminum with a UV stablised polycarbonate diffuser, IP 66 and IK 09 protection. The luminaire shall have a power factor > 0.9 and shall have 50,000 burning hours as per L70 criteria. The luminaire shall be BIS certified and shall comply all IEC safety requirements and test certificates of LM79 and LM80 reports shall be submitted. (Make : Philips WT202W LED6S CW PSU S1 PC or equivalent) <br>

10

-

-

... More
OD12047/2023-2024:Supply of 4 feet surface mounted battern type luminaire with a power consumption not more than 20 W, luminaire lumen output of 2000 lumens,luminaire efficacy > 120 lm/W with an operanting voltage range from 140 V - 270 V. The luminaire shall have a white CRCA housing with a poly carbonate diffuser to provide uniform light and a sleek design. The luminaire shall have a CCT of 6500 K , CRI > 80, power factor >0.95, SDCM < 5, THD <10% and 50,000 burning hours as per L70B50 criteria. The luminaire shall have flicker content <5% and shall have high and low cut off with auto restart feature. The luminaire shall be EMI/ EMC compliant and shall have a internal surge protection of 4 kV. The luminaire shall have Class - 1 Electrical Insulation, Class - B Serviceability (The driver can be replaced at site level). The luminaire and driver shall be BIS aprroved and test certificates of LM79 and LM80 reports shall be submitted. (Make: Philips BN308 LED20S 6500 L120 PSU WH or equivalent)

10

-

-

... More
OD12048/2023-2024:Supply, fixing, testing and commisioning of following rating and pole Isolator in existing Seven Segment Distribution Board, tier DBs and Vertical distribution board with spredear links, terminal connections and all accesories as required making all necessary connections etc as required and instructed by engineer in charge/consultant.<br>

1

-

-

... More
OD12049/2023-2024:Supplying, fixing, testing and commissioning following four pole and double pole , 415 volts and 240 volts, residual current circuit breaker with overload protection (RCBO) of the following rating and sensitivity current in the existing MCB SPN and TPN horizontal/vertical DB's complete with connections, etc. as required and instructed by engineer in charge/consultant.<br>25A 100mA FP RCBO<br>

2

-

-

... More
OD12087/2023-2024:Design, fabrication, supply, installation, testing and commissioning of cubicle type dust and vermin proof, made out of 16SWG /1.6 mm thick CRCA sheet duely rust inhibited,zinc passivated, phosphated and powder coated with approved colour, hinged and earthed front doors with name plate, danger notice board,heavy duty rubber gaskets removable gland plates made out of 2mm thick sheet steel as per specifications and interconnected with suitable Al Busbar. Rate shall be inclusive of ncessary relays, control wirings and terminations as required and as instructed by engineer in charge - Main panel<br>Incomer 1 :125A FP 25kA Microprocessor based MCCB ; Incomer 2 :125A FP 25A Microprocessor based MCCB ; Incomer 3 :125A FP 25A ATS with AMF; 125A 415V, 25kA best conductivity Al extensible TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required; RYB phase indicating LED lamps with control fuses and switches - 2 sets; Multi Function Digital Meter with CT, control fuses etc - 2 Nos.; Class B & Class C/ Class 1 & Class 2 Surge arrestor device - 1 Nos.; <br>Outgoings: 32A TPN SDF with 25A HRC fuse- 10 Nos.; 32A TP MCB - 2 Nos;

1

-

-

... More
OD12099/2023-2024:Supply and fixing the following accessories in the existing meter board and giving connections etc.100A HRC fuse base with fuse link<br>

3

-

-

... More
OD12100/2023-2024:Supply and fixing 100A TPN SDF on wall using suitable steel fastners.<br>

1

-

-

... More
OD12101/2023-2024:"Supply & installation of dust and vermin proof, 3 Phase Syntex Meter Board GSMB-6535(size 760x450x260x) and to fix KSEB meters, fuse units, CT etc as required including fixing it<br>on wall, making good the damages colour washing etc. as required."<br>

1

-

-

... More
OD12102/2023-2024:100 A, 415 V, 2 way neutral link mounted on DMC/ SMC base.<br

3

-

-

... More
OD12103/2023-2024:"Supply and providing following sizes of 'B' Class MS pipe with specials and flanged coupling in each full length of pipe, as additional exhaust piping, fixing the same firmly to the builing /<br>structure using necessary supports, such angle iron, MS clamp etc., painting the pipe and accessories with synthetic enamel paint over a coat of zinc chromate primer etc. as required.<br>100 mm dia or nearest size 'B' Class MS pipe"<br>

31

-

-

... More
OD12104/2023-2024:Supply, conveyance, installation, testing and commissioning of 40KVA/32KW D.G. set incorporating "CUMINS" Model X3.TAA-G2 Diesel Engine developing 56BHP at 1500rpm, Water cooled, 4cylinders, Coupled, ALternator rated at 32kw/40KVA, 415V, 50Hz, 0.8 P, mounted on a chanel iron base frame complete with fuel tank, Battery, Manuel control panel and other standard accessories with suitable CPCB approved factory assembled Acoustic enclosure.<br

1

-

-

... More
OD12105/2023-2024:Supply and providing 5 Kg. Dry Chemical Powder type Fire Extinguisher with hose and clamps including fixing it to wall as required.<br>

2

-

-

... More
OD12168/2023-2024:Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70 mm top diameter, 130 mm bottom diameter thickness 3mm base plate dimensions of 250x200x12 mm suitable for wind speed as per IS 875 Part III single arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc, complete 6 Meters

8

-

-

... More
OD12173/2023-2024:"Supply, installation, testing and commissioning of Solar LED lighting System with following accessories.<br>(a) luminaire :- 1No 45W LED IP 65 street light luminaire with epoxy powder coated pressure die cast alu. housing with weather proof gasket and heat resistant toughened glass cover, 100ah lithium battery, 250W solar panel, battery box, charge controller with auto switch built in for dusk to dawn operation having protection against short circuit & lightning with mounting bracket suitable to fix on tubular pole"<br

8

-

-

... More
OD12174/2023-2024:Preperation of shop drawings for the execution at site and getting them approved by engineer in charge/consultant before execution at site, preperation of As-built drawings of installation upon completion. Obtaining manuals, technical details,asbuilt/GA drawings and all specified test certificates from manufactures of all equipments from concerned and arranging technical class for maintenance staff of the complete installation for timely maintenance and working ,labeling of all DBs, SMDBs, panels, cable routing, marking etc in a professional manner and commissioning and handing over of the whole installation in a professional manner. Copies of drawings shall be taken as required for issuing to all concerned agencies working as a part of the project.

1

-

-

... More
Appendix F- Mechanical-E1-Fabrication, Supply, Erection and assembling of MS & SS EMBEDDED PARTS

-

-

-

... More
OD12184/2023-2024:Supply of MS plates confirming to IS 2062GrB including cost of conveyance charges

21570.85

-

-

... More
OD12189/2023-2024:Supply of MS Tees, Angles, Joists, ISMB, ISMC confirming to IS2062GrA/B including cost of conveyance charges

8763.39

-

-

... More
OD12188/2023-2024:Supply of MS round bar including cost of conveyance charges

1577.09

-

-

... More
OD12187/2023-2024:Supply of Bolt and Nut up to 300mm Length including cost of conveyance.

293.76

-

-

... More
85.108:Fabrication , erection and commissioning of Structural Steel Embedded parts in IS2062 Grade and accessories as per approved specifications, drawings and directions of deptl officer at site including cost of labour , machinery , incidental and handling charge etc complete but exculding cost of materials already supplied

31911.32

-

-

... More
OD12195/2023-2024:Fabrication, supply, erection and assembling in correct position and alignment by welding SS Embedded parts in 304L Grade like roller track, seal track, seal seat etc as per approved specifications, drawings and directions of deptl officer at site including cost of all materials, labour, machinery for planing, welding, shearing, grinding etc, lead and lift, conveyance, incidental and handling etc complete Rate analysis SS Embedded parts 2.6Qtl

6965.15

-

-

... More
Appendix G - Supply of materials, fabrication, painting and erection of MS REGULATING GATES

-

-

-

... More
OD12201/2023-2024:Supply of MS plates confirming to IS 2062GrB including cost of conveyance charges

82969.73

-

-

... More
OD12200/2023-2024:Supply of MS Tees, Angles, Joists, ISMB, ISMC confirming to IS2062GrA/B including cost of conveyance charges

3532.64

-

-

... More
OD12199/2023-2024:Supply of MS round bar including cost of conveyance charges

126.08

-

-

... More
OD12198/2023-2024:Supply of Bolt and Nut up to 300mm Length including cost of conveyance.

266.24

-

-

... More
OD12234/2023-2024:Fabrication and supply of Structural steel wheel gate and accessories as per approved specifications, drawings and directions of deptl officer at site including cost of labour, machinery, all leads and lifts, incidental and handling charges etc complete but excluding cost of material already supplied

86628.44

-

-

... More
85.112:Painting all the exposed surfaces of the gate and embedded parts with two coats of epoxy coal tar black paint confirming to IS14948 with a minimum film thickness of 150+/-5 microns per each coat over two coats of priming coat applied with zinc primer containing not less than 85% of zinc dry film with a film thickness of 70+/-5 microns , so that the total film thickness of all coats including priming coat at any rate is not less than 350microns over the grit blasted and cleaned surface to class A standard of IS 14177 including cost of all materials , labour charges , cost of testing all painting materials, all incidental charges, hire of T&P etc complete as per the direction of departmental officer at site

2443.46

-

-

... More
OD12206/2023-2024:Supply and stacking of dia 8mm SS-304 chain. including cost of materials, conveyance etc.complete dia 8mm SS-304 chain for Dogging beam

32

-

-

... More
85.111:Erection of the gates safely in the grooves , assembling and aligning including cost of all machinery, labour all incidental and conveyance charges etc complete as per direction of departmental officer at site

86628.44

-

-

... More
Appendix H - Supplying and fixing of RUBBER SEALS and RUBBER PAD for JOINT OF GATE

-

-

-

... More
85.116:Supplying and fixing in correct position with specified initial interface the flat type rubber seal confirming to IS 11855 to the gates including cost of SS bolts and nut all labour and machinery and incidental and conveyance charges complete as per approved specification and drawing

302.85

-

-

... More
85.118:Supplying and fixing in correct position with specified initial interface L-type / bulb nose rubber seal confirming to IS11855 to the gates including cost of SS bolts and nuts and all labour and machinery and incidental and conveyance charges complete as per approved specifications and drawings

96.19

-

-

... More
Appendix I- Supplying and fixing of ROLLER ASSEMBLY.

-

-

-

... More
85.120:Supplying and fixing cast steel thrust roller assembly having 300mm Dia, 90mm tread width, SS(304) shaft and 22314E self aligning spherical roller bearing and accessories as per approved specifications and drawings including cost of all materials, machineries, labour , all lift and lead, incidental and conveyance charges etc complete

64

-

-

... More
OD12292/2023-2024:Supplying and fixing side guide roller assembly having 130mm Dia, 90mm tread width, pin and Al Bronze bush and accessories as per approved specifications and drawings including cost of all materials, machineries, labour , all lift and lead, incidental and conveyance charges etc complete Rate analysis for 1 roller assembly

32

-

-

... More
Appendix J- Supply of materials, fabrication, painting and erection of HOSTING BRIDGE, COVERS and FRAMES of DRIVING UNITS & ROPE DRUM

-

-

-

... More
OD12211/2023-2024:Supply of MS plates confirming to IS 2062GrB including cost of conveyance charges

47196.17

-

-

... More
OD12212/2023-2024:Supply of MS Tees, Angles, Joists, ISMB, ISMC confirming to IS2062GrA/B including cost of conveyance charges

25992.47

-

-

... More
OD12213/2023-2024:Supply of MS round bar including cost of conveyance charges

803.29

-

-

... More
85.103:Supply of MS checquered plates including cost of conveyance charges

11417.06

-

-

... More
OD12279/2023-2024:Supply of GI pipe 32mm dia

321.2

-

-

... More
OD12344/2023-2024:Supply of MS Bolts and Nuts

422.88

-

-

... More
85.124:Fabrication and supply of Hoisting bride unit in structural steel confirming to IS2062 Gr including ladder, covers for hoisting unit etc as per approved specifications, drawings and directions of departmental officer at site including cost of labour, machinery, incidental and handling charges for fixing handrails and allied works etc complete but excluding material already supplied and weight of pipes for hand rails etc

86224.84

-

-

... More
OD12214/2023-2024: Painting all the exposed surfaces 2 coats of enamel paint over 1 coat of zinchromate primer as per IS 1477:1994 over the grit blasted and cleaned surface to class A standard of IS 14177 including cost of all materials, labour charges, cost of testing all painting materials, all incidental charges, hire of T&P etc complete as per the direction of departmental officer at site.

2465.31

-

-

... More
85.136:Erection of the hoisting bridge unit including handrails , ladder and platform etc. in correct alignment and anchoring it ; setting and aligning the covers of the hoisting unit etc complete including cost of all labour, machinery, incidental and conveyance , lead and lift charges etc complete but excluding cost of materials already supplied

96303.58

-

-

... More
Appendix K - Supplying, stacking, erecting and trial run of ROPE DRUM HOISTING UNIT and its ACCESSORIES

-

-

-

... More
85.128:Providing Line shaft ,material : MS rolled/ forged steel

2294.45

-

-

... More
OD12215/2023-2024:supply of PLUMMER BLOCK SNA 513TC to Suit for 60mm dia Line Shaft with 1213 EK Bearing + H213 adapter sleeve

32

-

-

... More
OD12291/2023-2024:Cost of supplying and stacking 20mm, 6/36 construction, right hand lay ungalvanised main fibre core wire rope <br> having UTS 180Kg/mm2 breaking load capacity 23853 Kg confirming to IS2266-1989

1360

-

-

... More
85.133:Supplying and stacking of 25 Tonne capcity rope drum hoisting unit having 13.5m lift at a hoisting speed of about 0.45 m/min(+/-10%) through pulley arrangements with 4 numbers of falls on either side with 20 mm tested galvanized wire rope 6/36 construction ;fibre core haing breaking capcity 23853 Kg and driven by TEFC squirrel cage induction motor hoist duty type having capacity not less than5 HP and driven through self locking worm reducer and open gear reduction unit excluding the cost of Line shaft but including 2 nos. of plummer blocks with bearings for line shaft supported at proper intervals and inlcuing cost of electro magnetic thruster brake assembly maual operating systems, electrical accessories like KOL Starters, limit switch, main switches and other safety eequipments as per drawings specification and statutory requirements etc complete buyt excluding cost of wire rope.

8

-

-

... More
OD12216/2023-2024:Providing DIAL ASSEMBLY

8

-

-

... More
85.125:Conveying and erecting in position the already supplied rope drum hoisting units ( 15T/20T/25T/30T) capacity on the hoisting bridge and correcting the alignment as far as possible manually as per the direction of departmental officer at site including cost of all labour, machinery, lead and lift and all incidental and conveyance charge etc complete

8

-

-

... More
85.135:Conveying and Fixing wire rope already supplied to the new gates and Hoisting unit safely and conducting Trial Run

8

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.