Kerala Irrigation Infrastructure Development Corporation Limited Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 1,00,000Document Cost
₹ 9,759Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_KIIDC_574224_1Bid Award Id
ViewTender No
IRR/KIIDC/TR/1599/2023_5_1_1/1Tender Authority
Kerala Irrigation Infrastructure Development Corporation Limited ViewPurchaser Address
-Website
http://http://kiidc.kerala.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
1.14.2:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
100
-
-
... More
1.14.3:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
15
-
-
... More
1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1
-
-
... More
1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
2
-
-
... More
1.32:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
1
-
-
... More
1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
8
-
-
... More
90.12.41.2:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp
10
-
-
... More
9.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
2
-
-
... More
90.11.1.18:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)
1
-
-
... More
90.12.7.40:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
10
-
-
... More
2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
1
-
-
... More
2.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
1
-
-
... More
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
6
-
-
... More
90.3.19.3:Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required1200 mm 1X20W LED Lamp with box type fixture
4
-
-
... More
90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
1
-
-
... More
OD31509/2022-2023:supply and fixing 30 watts or equivalent smart LED street light with IP65/66 protection (wall mounted aluminium clamp included)
4
-
-
... More
OD31510/2022-2023:supply and fixing 12W/equivalent LED Bulk head light IP65/66 rating
12
-
-
... More
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
200
-
-
... More
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
6
-
-
... More
5.13:Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
20
-
-
... More
5.15:Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
120
-
-
... More
4.1.6:Supplying and installing following size of perforated pre-painted M.S. cable trays with
perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.450 mm width X50 mm depth X 2.0 mm thickness
25
-
-
... More
OD32166/2022-2023:Supply and laying of 2.5 sqmm 3 core PVC/XLPE insulated armoured cable with aluminium conductors for working voltages up to and including 1100 volts conforming IS 1584/part I/1988 for PVC IS 7098 part I for XLPE
10
-
-
... More
OD32167/2022-2023:Supply and laying of 185 sqmm 3.5 core PVC/XLPE insulated armoured cable with aluminium conductors for working voltages up to and including 1100 volts conforming IS 1584/part I/1988 for PVC IS 7098 part I for XLPE
30
-
-
... More
OD32168/2022-2023:supply and laying of 240 sqmm 4 core PVC/XLPE insulated armoured cable with aluminium conductors for working voltages up to and including 1100 volts conforming IS 1584/part I/1988 for PVC IS 7098 part I for XLPE
48
-
-
... More
9.1.27:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)
6
-
-
... More
OD32170/2022-2023: Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4X 240 sq. mm
14
-
-
... More
90.12.1.23:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3 core 185 sq mm
90
-
-
... More
OD32169/2022-2023:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench 200/174 mm or nearest size
60
-
-
... More
90.16.1.7:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required7.10 mm copper conductor ( 2 SWG)
80
-
-
... More
OD32376/2022-2023:Supply and fixing following capacity TP & N disconnector fuse switch unit with sheet steel enclosure directly on wall using suitable anchor bolts as required- 160A TPN SFU
3
-
-
... More
OD32174/2022-2023:Supply , installing and commisioning of outdoor 11KV/433V 315KVA transformer with DP structure also including primary side control and protection (A.b switch, lightning arrester, D.o fuse) and secondary control and protection (MCCB having isolation duty and E/F release and stand by low set E/f relay using CT at neutral earthing conductor or ACB with propoer current setting facility with 3 O/C and 1 E/f realease
1
-
-
... More
5.9:Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
20
-
-
... More
OD32678/2022-2023:Earthing with G.I. earth plate 1200 mm X 1200 mm X 6 mm thick including accessories, andproviding masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
3
-
-
... More
OD32669/2022-2023:MSB(main switch board):Supply,installation,testing and commissiong of MSB panel fabricated out of 16SWG CRCA sheet ,powder coated dust and vermin tight proof,front opening type, cable top/ bottom entry type,flush , floor mounted and also including base frame (incomer:630A 36KA 4pole MCCB-1 nos, outgoing:250A 23KA 4pole MCCB-4 nos , 63A 4 pole MCCB-1 nos and also include suitable aluminium bus bar dimension)
1
-
-
... More
OD32674/2022-2023:APFC(Automatic power factor control panel):Supplying, Installation, Testing & Commissioning of floor mounted supported compartmentalized indoor type dust, weather and vermin proof cubical 150KVAr , (1 x 50KVAR + 1 x 20 KVAR + 2 x 15 KVAR + 4 x 10 KVAR + 1 x 5 KVAR)APFCR panel i/c capacitor, contactor,relay of suitable capacity, fabricated out of 2 mm thick CRCA Sheet Steel of suiatble size depth not less than 400mm with hinged door and suitable for continous operation on 3 Phase 415 V, 50 Hz, 4 wire AC supply with detachable gland plate in cable alley including providing and fixing following switchgears and accessories therein connections and interconnections with PVC insulated multi strand copper flexible conductor duly sleeved, tag, lugs etc and painted with powder coated paint after eight tank treatment, earthing the body etc. as required.
1
-
-
... More
OD32673/2022-2023:METERING PANEL : Supply, installation,testing and commissioning of meteing panel eather proof water resistant material and panel fabricated with 16SWG CRCA sheet , CT unit, PT unit, NCT included( excluding HT TOD meter)
1
-
-
... More
OD32675/2022-2023:OD : 100 A, 415 V, 2 way neutral link mounted on DMC/ SMC base
1
-
-
... More
OD32676/2022-2023:Supply and installing 150A HRC fuse fuse base with fuse link<br>
3
-
-
... More
OD32173/2022-2023:charges for preparation of electrical drawings and taking approval from KSEB and Electrical Inspectorate office
1
-
-
... More
Appendix B - Constuction of intake well
-
-
-
... More
100.3.1.2:Earthwork in open well excavation (above water) for wells of diameter up to 2.50m in all kinds of soil and conveying and depositing the spoil within initial lead of 50m and lift from 1.5m to 3.0m including neat banking.
39.98
-
-
... More
100.4.S.6:15% extra for additional lift excluding cost of materials.
17.35
-
-
... More
4.1.2:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:1/2:3 (cement : 11/2 coarse sand : 3 graded stone aggregate 20 mm nominal size)
0.6
-
-
... More
OD32755/2022-2023:RING BUND Type II Putting up ring bund with earth fille gunny bags of top width 1.5m bottom width 3.0m height 3.0 m side and filling in between with earth to form ring bund and maintaining the same leak proof till the completion of the work and clearing the site by dismantling the bund after completion of the work.etc.complete.
35
-
-
... More
60.2.2:Bailing out water Using 5HP Pump- Bailing out water with 5HP engine and pump set including conveyance to site and erection,cost of fuel, lubrication oil and other stores, pay of staff etc complete
160
-
-
... More
60.2.3:Bailing out water using pump above 5 HP and Up to 10 HP-Bailing out water with engine and pump set above 5HP and up to 10HP, including conveyance to site and erection,cost of fuel, lubrication oil and other stores, pay of staff etc complete
120
-
-
... More
60.2.4:BAILING OUT WATER USING PUMP ABOVE 10HP AND UP TO 20HP - Bailing out water with engine and pump set above 10HP and up to 20HP, including conveyance to site and erection,cost of fuel, lubrication oil and other stores, pay of staff etc complete
80
-
-
... More
5.2.2:Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
14.48
-
-
... More
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
84.78
-
-
... More
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
1158.64
-
-
... More
APPENDIX-C PROVIDING COMMUNITY MICRO IRRIGATION SUBMAIN WORKS
-
-
-
... More
OD31921/2022-2023:DESIGN, SUPPLY, INSTALLATION, TESTING, AND COMMISSIONING OF SUB-MAIN MICRO-IRRIGATION SYSTEM AS PER THE IS SPECIFICATIONS AND APPROVED DESIGN FROM KIIDC DESIGN WING INCLUDING ALL SUBMAIN PVC PIPELINES-IND, PLACING EMITTER TAKE-OFF AND FITTINGS, ACCESSORIES, FLUSH VALVES, IRRIGATION CONTROL VALVES, AND FITTINGS AND ACCESSORIES, SUPPLY OF SPARE PARTS, TOOLS ETC WITH ALL COST OF MATERIALS, LABOUR CHARGES, COST OF FITTINGS, CONVEYANCE INCLUDING ALL COST OF TRENCHING, BACKFILLING, AND LAYING AS PER DESIGN ALIGNMENT AND LEVELS, IF ANY, ETC, INCLUDING MATERIAL TEST REPORT FROM THE THIRD PARTY QUALITY CONTROL UNIT, AS PER THE SPECIFICATIONS AND DIRECTIONS OF DEPARTMENTAL OFFICERS AT SITE.
19600
-
-
... More
APPENDIX-D PROVIDING COMMUNITY MICRO IRRIGATION MAINLINE WORKS
-
-
-
... More
OD31923/2022-2023:DESIGN, SUPPLY, AND INSTALLATION, TESTING AND COMMISSIONING OF MAINLINE MICRO-IRRIGATION SYSTEM AS PER THE IS SPECIFICATIONS AND APPROVED DESIGN FROM KIIDC INCLUDING MAIN LINE PVC PIPE LINES -IND, FERTIGATION UNIT, IRRIGATION CONTROL VALVES FOR MAINLINE, FITTINGS AND ACCESSORIES, SUPPLY OF SPARE PARTS, TOOLS ETC WITH ALL COSTS OF MATERIALS, LABOUR CHARGES, COST OF FITTINGS, CONVEYANCE INCLUDING ALL COSTS OF TRENCHING, BACKFILLING, AND LAYING AS PER DESIGN ALIGNMENT AND LEVELS IF ANY, ETC INCLUDING, MATERIAL TEST REPORT FROM THE THIRD PARTY CONTROL UNIT, AS PER THE SPECIFICATIONS AND DIRECTIONS OF DEPARTMENTAL OFFICERS AT THE SITE.
19600
-
-
... More
APPENDIX-E PROVIDING COMMUNITY MICRO IRRIGATION AUTOMATION AND HEAD UNIT
-
-
-
... More
OD31924/2022-2023:DESIGN, SUPPLY, INSTALLATION, TESTING AND COMMISSIONING, OPERATION AND MAINTENANCE, FORMING AND REGISTERING WATER USERS ASSOCIATION AND PROVIDING TRAINING TO THE FARMERS, AND TRANSFER OF MICRO-IRRIGATION SYSTEM ON BUILD OPERATE MAINTAIN, AND TRANSFER BASIS COMPLETE, CONSISTING OF THE FOLLOWING: MICRO-IRRIGATION SYSTEM INCLUDING PRIMARY FILTERS, SECONDARY FILTERS (FULLY AUTOMATIC FILTERS), AUTOMATED IRRIGATION CONTROLLERS, LAYING AND FIXING OF PRESSURE COMPENSATING EMITTERS, LAYING OF LATERALS, END CAP FOR LATERALS, PRESSURE RELIEF VALVES, BUTTERFLY VALVES, AIR RELEASE VALVES, SOLENOID VALVES, VALVES, QUICK RELEASE VALVES, NON-RETURN VALVES, PRESSURE GAUGES, SWING CHECK VALVES, SOIL MOISTURE SENSORS, IRRIGATION WIRELESS CONTROLLERS AND ALL RELATED FITTINGS AND ACCESSORIES, SUPPLY OF SPARE PARTS, TOOLS ETC, INDIVIDUAL SHIFT-WISE WATER METER, SUITABLE SUBMERSIBLE MOTOR WITH AN AUTOMATED OPERATION CONTROLLER (INCLUDING ALL OTHER FITTINGS, GI FITTINGS) AUTOMATED STARTER (Variable-frequency drive), AND PANEL BOARD, AND ALL RELATED FITTINGS FOR THE COMMISSIONING OF HEAD UNIT, AS PER DESIGN AND IS SPECIFICATION ETC., COMPLETE, MATERIALS TEST REPORT FROM THIRD-PARTY QUALITY CONTROL UNIT. SOIL TESTING AT FREQUENCY AS REQUIRED WITH EXPERIENCED STAFF, MACHINERY AND EQUIPMENT FOR EXECUTION, QUALITY CONTROL ARRANGEMENTS, PREPARATION OF PRODUCTION PLAN, OBTAINING CONSENT FROM FARMERS FOR LAYING PIPES AND ALLIED WORKS IN THEIR PROPERTY, MARKET STUDY AND ADVISING FARMERS ON CROP SELECTION BASED ON WATER AVAILABILITY, MARKET STUDY AND ALL MATERIALS AND FITTINGS, ADHESIVES SHALL BE AS PER THE SPECIFICATIONS AND STANDARDS OF BIS/INTERNATIONAL CODES INCLUDING REQUISITE MANPOWER FOR OPERATION AND MAINTENANCE OF THE SYSTEM FOR THREE YEARS AFTER THE DATE OF COMPLETION ON A TURNKEY BASIS AS PER THE DIRECTION OF DEPARTMENTAL OFFICIALS AT THE SITE
19600
-
-