Kerala Irrigation Infrastructure Development Corporation Limited Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 1,00,000Document Cost
₹ 9,759Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_KIIDC_576312_1Bid Award Id
ViewTender No
IRR/KIIDC/TR/2100/2023_5_1_1/3Tender Authority
Kerala Irrigation Infrastructure Development Corporation Limited ViewPurchaser Address
-Website
http://http://kiidc.kerala.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
60.2.2:Bailing out water Using 5HP Pump- Bailing out water with 5HP engine and pump set including conveyance to site and erection,cost of fuel, lubrication oil and other stores, pay of staff etc complete
56
-
-
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
99.12
-
-
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
58.01
-
-
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
44.6
-
-
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
86.4
-
-
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
112.69
-
-
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
115.34
-
-
5.9.19:Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges
3.31
-
-
5.9.16.1:Centering and shuttering including strutting, etc. and removal of form for:
Edges of slabs and breaks in floors and wallsUnder 20 cm wide
10.4
-
-
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
24.55
-
-
5.2.2:Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
29.11
-
-
4.3.1:Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns
15
-
-
4.3.2:Centering and shuttering including strutting, propping etc. and removal of form work for:Retaining walls, return walls, (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc.
91.95
-
-
4.2.3:Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
51.42
-
-
60.7.1:DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site
2.25
-
-
60.7.2:DR PACKING Under foundation - Dry stone packing under foundation with good quality blasted rubble including conveyance of material and labour charges etc. complete as per direction of departmental officers at site.
17.33
-
-
60.2.1:EARTH WORK FILLING- Supplying contractors own earth including cost of conveyance and royalty and filling (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
36.32
-
-
50.6.1.5:Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
8.81
-
-
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5026.2
-
-
5.22A.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more
2911.3
-
-
13.1.2:12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand).
357.32
-
-
13.16.1:6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
135.15
-
-
10.6.2:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.20 mm M.S. laths with 1.20 mm thick top cover
4.2
-
-
10.7:Providing and fixing ball bearing for rolling shutters.
2
-
-
9.48.1:Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding
109.35
-
-
9.147.5:Providing and fixing factory made uPVC white colour casement/casement cum
fixed glazed windows comprising of uPVC multi-chambered frame, sash and
mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2
mm thick galvanized mild steel section made from roll forming process of required
length (shape & size according to uPVC profile), uPVC extruded glazing beads of
appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction
hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8
mm size for fixing frame to finished wall, plastic packers, plastic caps and
necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut
and fusion welded at all corners, mullion (if required) shall be also fusion welded
including drilling of holes for fixing hardware's and drainage of water etc. After
fixing frame the gap between frame and adjacent finished wall shall be filled with
weather proof silicon sealant over backer rod of required size and of approved
quality, all complete as per approved drawing & direction of Engineer-in-Charge.
(Single / double glass panes and silicon sealant shall be paid separately)<br>
Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance
in dimension i.e. in depth & width of profile shall be acceptable.Casement window double panels with S.S. friction hinges (350 x 19 x 1.9 mm) made of (big series)frame 67 x 60 mm & sash / mullion 67 x 80 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension. (Area of window above 1.50 sqm).
6.08
-
-
13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
11.12
-
-
21.3.1:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness
6.08
-
-
13.46.1:Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
492.36
-
-
11.37:Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.
68.92
-
-
60.6:PVC WEEP HOLES- Providing weep holes using 75mm dia. PVC pipes working pressure 4kg /sq.cm including cost of materials, conveyance, labour charges etc. complete.
6.5
-
-
Appendix B :Maintenance of pond & desilting
-
-
-
2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
400
-
-
60.2.3:Bailing out water using pump above 5 HP and Up to 10 HP-Bailing out water with engine and pump set above 5HP and up to 10HP, including conveyance to site and erection,cost of fuel, lubrication oil and other stores, pay of staff etc complete
120
-
-
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
600
-
-
60.7.3:DISMANTLING DR - Dismanling , clearing away and carefully stacking materials useful for reuse for any thickness of walls in DR masonry including disposal of debris within a distance of 150m.
52
-
-
60.7.8:DR with Departmental. Stone - DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course using departmental rubble including packing to compactness to lines and levels, labour charges etc. complete as per direction of Departmental officers at site
28
-
-
60.7.1:DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site
63.8
-
-
7.2.1:Random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceiling level and the like.Cement mortar 1:6 (1 cement : 6 coarse sand)
20
-
-
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
44
-
-
4.1.5:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
38.8
-
-
Appendix C- Construction of Cistern
-
-
-
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
36.31
-
-
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
5.73
-
-
4.2.3:Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
10.32
-
-
4.3.2:Centering and shuttering including strutting, propping etc. and removal of form work for:Retaining walls, return walls, (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc.
60.8
-
-
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
825.68
-
-
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)
39.36
-
-
Electrification
-
-
-
1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group C
4
-
-
1.12:Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
30
-
-
1.14.1:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
55
-
-
1.14.2:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
50
-
-
1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
2
-
-
1.32:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
2
-
-
1.55.3:Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
3
-
-
90.11.1.10:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)
1
-
-
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
12
-
-
2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
1
-
-
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
1
-
-
1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1
-
-
1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
5
-
-
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
4
-
-
5.8:Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
55
-
-
5.14:Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
25
-
-
5.19:Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
15
-
-
OD33315/2022-2023:Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 3.5cx185sq.mm Al Cable
15
-
-
OD33316/2022-2023:Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 3.5cx70sq.mm Al Cable
40
-
-
OD33810/2022-2023:Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 3.5cx50sq.mm Al Cable
25
-
-
OD33319/2022-2023:Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminiumconductor power cable confirming to IS 7098 (part 1) ammended upto date. 4cx10sq.mm Al Cable
15
-
-
4.1.1:Supplying and installing following size of perforated pre-painted M.S. cable trays with
perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6 mm thickness
20
-
-
7.8.1:Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV
grade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
15
-
-
7.8.2:Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV
grade of following size on cable tray as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
65
-
-
7.8.3:Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV
grade of following size on cable tray as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
15
-
-
9.1.22:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)
2
-
-
9.1.23:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)
4
-
-
9.1.27:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)
2
-
-
9.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
2
-
-
90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
1
-
-
OD33322/2022-2023:supply and fixing 9 or 10W IP65/66 rating surface or wall mounted LED Bulk head light.
4
-
-
90.3.19.3:Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required1200 mm 1X20W LED Lamp with box type fixture
4
-
-
OD33809/2022-2023:Supply and erection of Double pole structure as per the latest KSEB standards using ISMB poles with RS joist with supply installation testing and commissioning of outdoor CT PT unit as per KSEB standards (10/5A Cl:0.2S 10VA CT), required quantity of MS channel for mounting AB switch, DO fuses Lightning arrestors etc with MS flats clamps base plate bolts nuts etc. including cutting welding aluminium painting all as per standard requirements of Electrical inspectorate complete including supply and installation of following over headline accessories as required. 11KV pin insulator. 11KV Disc insulators as required,11KV 400A 3 phase gang operated vertical single make or break type off load Air brake switches complete with all hardware like insulators, fixing channels operating rods, handle locking arrangements bolts nuts and complete, lighting arrestors, 11kV dropout fuse sets complete with all hardware like supporting insulators, fuse rods, bolts and nuts complete. Pipe earth electrode for the DP structure LA Earthing 6 SWG Copper for Lightning arrestor earthing including all round fencing with all round clearance of 1.25 meter and filling of 40mm granite gully in the yard.
1
-
-
OD33771/2022-2023:Supply, installation, testing and commissioning of oil cooled outdoor 100kVA, 11kV/433volts, 3phase,50Hz, Dyn11, ONAN type, Aluminium wound transformer with off load tap changing arrangement, having HV bushing on HV and LV side with cable end box and 2x3.5Cx50sqmm XLPE insulated Al. armourded cable on LV side complete with all accessories, first filling of filtered dehydrated oil and confirming to IS 1180(part1), level-1, losses as per IS standards . The scope including erection of the transformer on the existing double pole structure/foundation is included in the scope of work. All the works shall be done as per the Engineer in charge and prior approval shall be taken before the supply and all the test certificates shall be submitted.
1
-
-
OD33788/2022-2023:Supply, installation, testing and commissioning of 11kV HT Outdoor metering cubicle of IP54 including HT TOD meter, HT fuses as per the KSEB standards in the existing foundation.
1
-
-
OD33781/2022-2023:Supply, installation, testing and commissioning of outdoor Main panel LT cubicle IP54 with 2 mm thick CRCA sheet, gland plates, 160A Al. busbar including supply and installation of 160A 4P 36kA MCCB set at 133.3A having isolation duty, microprocessor based (Ics=100%Icu), Extended rotary handle, spreader and E/F release, SC & OC with stand by low set E/F relay using suitable size Neutral CT at neutral earthing conductor in the existing foundation for mounting the panel is scope of the work.
1
-
-
OD33807/2022-2023:Supply ,Installation, testing & commissioning of cubicle type floor mounted Panel suitable for 415V,3 phase, 4 wire 50 Hz AC supply system fabricated in compartmentalised design from CRCA Sheet steel of 1.6mm thick for frame work and covers, 2mm thick for gland plates i/c cleaning and finishing complete with 7 tank process for powder coating in approved shade, having 200amps capacity TPN Aluminium bus bar of high conductivity, DMC/SMC bus bar supports, bottom base channel of section not less than 75 mm X 40mm X 5mm thick with following fabrication shall be done in transportable section, entire panel shall have a common copper earth bar of size 25mm X5mm at the rear with 2 nos. earth stud, solid connections for main bus bar to switch gears with required size of Aluminium bus bars and control wiring with 1.5 sq.mm. FRLS PVC Insulated copper conductor single core cable, cable alleys, cable gland plates, MV danger notice board i/c providing following switch gears complete as required . Incomer: 160 Amps, 36KA (ics = 100% icu ), 415 Volts, 50Hz, 4 pole MCCB with microprocessor based releases for over load, short circuit, control and monitoring accessories, 6A SPMCB and LED indicating Lamps for R,Y B indication, extended rotary handle, spreader and digital MFM with 3 nos. 160A Cl:1 15VA CT, Earth leakage relay with CBCT etc. -1 set. Outgoing: 1. 160 Amps, 25KA (Ics = 100% Icu ), 415 Volts, 50Hz, 3 pole MCCB with thermal magnetic based release for OL / SC release, extended rotary handle, spreader etc. -2 Nos., 2. 40A 10kA 4P MCB-1 no, 3.125 Amps, 25KA (Ics = 100% Icu ), 415 Volts, 50Hz, 3 pole MCCB with thermal magnetic based release for OL / SC release, extended rotary handle, spreader etc. -1 Nos Panel complete as above.
1
-
-
OD33808/2022-2023:Supply, installation, testing and commissioning of floor mounted type indoor automatic power factor correction panel fabricated with 16 SWG CRCA sheet, powder coated, aluminium busbar, wiring, separate metering compartment, base channel 75x40mm etc. The panel consisting of the provisions as i) Metalized poly propylene capacitors of 50 KVAR rating of 5 steps (20kVR+10kVArx2+5kVArx2) switching stages with necessary rating MCBs as outgoing ii) Incomer feeder fitted with 125A TP ISO. iii) Separate metering compartment with digital Ammeter, Voltmeter. iv) 6 stage Microprocessor based controller auto manual selector switch. v)Emergency push button to switch off the panel. vi)Capacitor duty contactors of adequate rating. vii) Manual switching push button with phase indications. the items including necessary safety features, relays and protections and fixing accessories.
1
-
-
OD33334/2022-2023:Charges towards preparation of all drawings and getting approval from the statutory bodies.
1
-
-
OD34087/2022-2023:Supplying and installing at approved location approved make fire buckets of 24 gauge galvanized steel sheet, standard 9 litre capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letters FIRE in black and gold. Cost shall be inclusive of providing MS stand for 2 nos of fire buckes, or , duly painted over a coat of primer.
1
-
-
OD34088/2022-2023:Supply installation of 4.5kg CO2 Fire Extinguisher fitted with Discharge hose and horn and wheel type, valve with initial Charge .
1
-
-
OD34089/2022-2023:Supply & fixing of Electrical rubber mat, used for high voltage up to 1.1kV, 2 Mtr x 1 Mtr size 2 mm thick, as per IS. 15652 - 2006. with ISI certification mark of standard 1 Mtr width. The work includes cleaning of the floor, fixing of insulation mat by using suitable adhesive, waterproofing compound, sealing materials etc., complete as required.
5
-
-
OD34090/2022-2023:Supply and providing good quality First Aid Box.
1
-
-
APPENDIX-A PROVIDING COMMUNITY MICRO IRRIGATION SUBMAIN WORKS
-
-
-
OD33823/2022-2023:DESIGN, SUPPLY, INSTALLATION, TESTING, AND COMMISSIONING OF SUB MAIN MICRO-IRRIGATION SYSTEM AS PER THE IS SPECIFICATIONS AND APPROVED DESIGN FROM KIIDC DESIGN WING INCLUDING ALL SUBMAIN PVC PIPELINES-IND, PLACING EMITTER TAKE-OFF AND FITTINGS, ACCESSORIES, FLUSH VALVES, IRRIGATION CONTROL VALVES, AND FITTINGS AND ACCESSORIES, SUPPLY OF SPARE PARTS, TOOLS ETC WITH ALL COST OF MATERIALS, LABOUR CHARGES, COST OF FITTINGS, CONVEYANCE INCLUDING ALL COST OF TRENCHING, BACKFILLING, AND LAYING AS PER DESIGN ALIGNMENT AND LEVELS, IF ANY, ETC, INCLUDING MATERIAL TEST REPORT FROM THE THIRD PARTY QUALITY CONTROL UNIT, AS PER THE SPECIFICATIONS AND DIRECTIONS OF DEPARTMENTAL OFFICERS AT SITE.
15000
-
-
APPENDIX-B PROVIDING COMMUNITY MICRO IRRIGATION MAINLINE WORKS
-
-
-
OD33824/2022-2023:DESIGN, SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF MAINLINE MICRO-IRRIGATION \ SYSTEM AS PER THE IS SPECIFICATIONS AND APPROVED DESIGN FROM KIIDC INCLUDING MAIN LINE PVC PIPE LINES -IND, FERTIGATION UNIT, IRRIGATION CONTROL VALVES FOR MAINLINE, FITTINGS AND ACCESSORIES, SUPPLY OF SPARE PARTS, TOOLS ETC WITH ALL COSTS OF MATERIALS, LABOUR CHARGES, COST OF FITTINGS, CONVEYANCE INCLUDING ALL COSTS OF TRENCHING, BACKFILLING, AND LAYING AS PER DESIGN ALIGNMENT AND LEVELS IF ANY, ETC INCLUDING, MATERIAL TEST REPORT FROM THE THIRD PARTY CONTROL UNIT, AS PER THE SPECIFICATIONS AND DIRECTIONS OF DEPARTMENTAL OFFICERS AT THE SITE.
15000
-
-
APPENDIX-C PROVIDING COMMUNITY MICRO IRRIGATION AUTOMATION AND HEAD UNIT
-
-
-
OD33825/2022-2023:DESIGN, SUPPLY, INSTALLATION, TESTING, AND COMMISSIONING, OPERATION AND MAINTENANCE, FORMING AND REGISTERING WATER USERS ASSOCIATION AND PROVIDING TRAINING TO THE FARMERS, AND TRANSFER OF MICRO-IRRIGATION SYSTEM ON BUILD OPERATE MAINTAIN, AND TRANSFER BASIS COMPLETE, CONSISTING OF THE FOLLOWING: MICRO-IRRIGATION SYSTEM INCLUDING PRIMARY FILTERS, SECONDARY FILTERS (FULLY AUTOMATIC FILTERS), AUTOMATED IRRIGATION CONTROLLERS, LAYING AND FIXING OF PRESSURE COMPENSATING EMITTERS, LAYING OF LATERALS, END CAP FOR LATERALS, PRESSURE RELIEF VALVES, BUTTERFLY VALVES, AIR RELEASE VALVES, SOLENOID VALVES, VALVES, QUICK RELEASE VALVES, NON-RETURN VALVES, PRESSURE GAUGES, SWING CHECK VALVES, SOIL MOISTURE SENSORS, IRRIGATION WIRELESS CONTROLLERS AND ALL RELATED FITTINGS AND ACCESSORIES, SUPPLY OF SPARE PARTS, TOOLS ETC, INDIVIDUAL SHIFT-WISE WATER METER, SUITABLE SUBMERSIBLE MOTOR WITH AN AUTOMATED OPERATION CONTROLLER (INCLUDING ALL OTHER FITTINGS, GI FITTINGS) AUTOMATED STARTER (Variable-frequency drive), AND PANEL BOARD, AND ALL RELATED FITTINGS FOR THE COMMISSIONING OF THE HEAD UNIT, AS PER DESIGN AND IS SPECIFICATION, ETC., COMPLETE, MATERIALS TEST REPORT FROM THIRD-PARTY QUALITY CONTROL UNIT. SOIL TESTING AT FREQUENCY AS REQUIRED WITH EXPERIENCED STAFF, MACHINERY AND EQUIPMENT FOR EXECUTION, QUALITY CONTROL ARRANGEMENTS, PREPARATION OF PRODUCTION PLAN, OBTAINING CONSENT FROM FARMERS FOR LAYING PIPES AND ALLIED WORKS IN THEIR PROPERTY, MARKET STUDY AND ADVISING FARMERS ON CROP SELECTION BASED ON WATER AVAILABILITY, MARKET STUDY AND ALL MATERIALS AND FITTINGS, ADHESIVES SHALL BE AS PER THE SPECIFICATIONS AND STANDARDS OF BIS/INTERNATIONAL CODES INCLUDING REQUISITE MANPOWER FOR OPERATION AND MAINTENANCE OF THE SYSTEM FOR THREE YEARS AFTER THE DATE OF COMPLETION ON A TURNKEY BASIS AS PER THE DIRECTION OF DEPARTMENTAL OFFICIALS AT THE SITE
21000
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements