Kerala Irrigation Infrastructure Development Corporation Limited Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 1,00,000Document Cost
₹ 9,759Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_KIIDC_581289_1Bid Award Id
ViewTender No
KIIDC/TR/1786/2023_5_1_1/RC 1/1Tender Authority
Kerala Irrigation Infrastructure Development Corporation Limited ViewPurchaser Address
-Website
http://http://kiidc.kerala.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
140.25
-
-
... More
4.3.1:Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns
54.31
-
-
... More
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
178.2
-
-
... More
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
37.4
-
-
... More
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
100.62
-
-
... More
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
2992.32
-
-
... More
2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
155.65
-
-
... More
OD4583/2023-2024:Stonework for construction of 'Vilakkumadam" in plain ashlar in foundation and basement in cement mortar 1:6 (1 cement: 6 coarse sand) including pointing with cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade: (Outer faces dressed) Granite stone
73.43
-
-
... More
OD4584/2023-2024:Stonework for construction of 'Vilakkumadam" in plain ashlar in structure above plinth such as Piller, Beam, Wall etc., in cement mortar 1:6 (1 cement: 6 coarse sand) including pointing with cement mortar 1:2 (1 white cement: 2 stone dust) with an admixture of pigment matching the stone shade: (All faces dressed). As per specified design/direction of engineer at site. Granite stone.
62.21
-
-
... More
OD4585/2023-2024:Providing 24x24cm granite stone piller with "Pothika" for vilakkumadam outer, as per the design and drawing of the Architect including all cost and conveyance, labour charges etc complete. height 155cm piller and 15 cm "Pothika". Above plinth level.
64
-
-
... More
OD4586/2023-2024:Stone work in plain ashlar in superstructure up to floor V level including granite lamp with azhi (3 lamps for 1 azhi)
222
-
-
... More
OD4587/2023-2024:Providing and fixing 30 mm granite stone laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with cement. complete at all levels. Area of slab over 0.50 sqm
360.4
-
-
... More
OD4588/2023-2024:Dismantling dressed stone pilers from existing Vilakkumadam, by manually/mechanical means including stacking of serviceable and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge
30
-
-
... More
OD4589/2023-2024:Stonework for construction of Vilakkumadam in plain ashlar in foundation and basement by using stacked depatmental material (Disamandled from existing Vilakkumadam structure) in cement mortar 1:6 (1 cement: 6 coarse sand) including. pointing with cement mortar 1:2 (1 white cement: 2 stone dust) with an admixture of pigment matching the stone shade: (Outer faces dressed) Granite stone
72.39
-
-
... More
OD4590/2023-2024:Providing and fixing of granite stone piler by using stacked departmental material (Dismantled from existing Vilakkumadam structure) with "Pothika" for vilakkumadam outer face, as per the design and drawing of the Architect including all cost and conveyance, labour charges etc complete. Above plinth level.
30
-
-
... More
Revival of pond
-
-
-
... More
15.9.2:Demolishing stone rubble masonry manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in- Charges:In cement mortar
147
-
-
... More
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
24.5
-
-
... More
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
32.88
-
-
... More
4.3.1:Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns
19
-
-
... More
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
137.81
-
-
... More
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
10.76
-
-
... More
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
24.5
-
-
... More
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
753.41
-
-
... More
50.6.7.1:Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for foundation and basement including all cost of materials, labour charges etc.
16.88
-
-
... More
OD4591/2023-2024:Providing and fixing 30 mm granite stone laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with cement. complete at all levels. Area of slab over 0.50 sqm
240
-
-
... More
Eletrification
-
-
-
... More
OD4592/2023-2024:Supply and fixing cast iron post top lanternd 28W inbuilt LED with shade of size 540x450mm with powder coated finish an giving connection as required
40
-
-
... More
OD4593/2023-2024:Supplying & fixing Cast iron lamp pole of height 4mtrs. base dia.250mm and top dia.75mm (weight 110kg. Arox. with provision for fixing MCB and cably entry/exit at bottom made of FG15 grade cast iron with MRF apoxy black finish over a coat of zinc chromate base on existing concrete foundation using foundation bolts, nuts nd washers.
40
-
-
... More
OD4594/2023-2024:Supply and fixing 32A, 4way connector in the existing junction box
40
-
-
... More
90.12.1.3:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).2 core 10 sq mm
1100
-
-
... More
90.12.2.3:Supply and laying of one number additional PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground in the same trench in one tier horizontal formation including widening the trench by 20 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil)2 core 10 sq mm
50
-
-
... More
90.12.1.4:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).2 core 16 sq mm
50
-
-
... More
90.12.7.4:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 16 sq mm with factory made clamp
20
-
-
... More
9.1.3:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 16 sq. mm (22mm)
2
-
-
... More
9.1.2:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm)
38
-
-
... More
90.12.9.2:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size
1561
-
-
... More
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
1500
-
-
... More
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
300
-
-
... More
2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
1
-
-
... More
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
4
-
-
... More
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
1
-
-
... More
2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual
current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
1
-
-
... More
5.3:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.
1
-
-
... More
OD4595/2023-2024:SITC Of feeder pillar complete with the following accessories. Incomer: 40A, DP<br>Isolator. 40A, DP, RCCB, 100mA. Outgoing: 10A, SP MCB - 4 Nos
1
-
-
... More
5.13:Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
10
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements