Kerala Industrial Infrastructure Development Corporation Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kerala Industrial Infrastructure Development Corporation - KINFRA Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date12 Sep 2024
Closing Date11 Oct 2024
Tender Amount₹ 7,64,92,454 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
4.12 : Providing, laying, spreading and compacting graded stone aggregate to Wet Mix Macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.

3664.38

-

-

... More
5.1.a : Providing and applying primer coat with bitumen emulsion ( SS) on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.70 - 1.0 kg/sqm using mechanical means.

24099.52

-

-

... More
5.2.b : Providing and applying tack coat with bitumen emulsion (RS) using emulsion pressure distributor at the rate of 0.25 - 0.30 kg per sqm on the prepared Granular Surface cleaned with mechanical broom.

23629.52

-

-

... More
5.2.a : Providing and applying tack coat with bitumen emulsion( RS) using emulsion pressure distributor at the rate of 0.20 - 0.30 kg per sqm on the prepared bituminous surface cleaned with mechanical broom.

23277.24

-

-

... More
5.4.2b : Dense Graded Bituminous Macadam : - For grading - II (26.5 mm nominal size) br Providing and laying dense graded bituminous macadam with 100-120 TPH batch type HMP producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder (VG 30) @ 4.0 to 4.5 per cent by weight of total mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MoRTH specification clause No. 505 complete in all respects.

1163.87

-

-

... More
5.6.2.b : Providing and laying bituminous concrete with 100-120 TPH hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder (NRMB) @ 5.4 per cent of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 507 complete in all respects br For Grading -II (13.2 mm Nominal size). br

698.32

-

-

... More
8.2.B : Construction of cement concrete kerb with channel with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 Grade PCC Using Concrete Batching and Mixing Plant on M10 grade foundation 150 mm thick, kerb channel 300 mm wide, 50 mm thick in PCCM20 grade, sloped towards the kerb, kerb stone with channel laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 409br

4253.8

-

-

... More
8.13 : Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads on Bituminous Surface @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.

1022.38

-

-

... More
Augmentation of Internal Roads -PLOT A, Plot F & plot C- Part 2

-

-

-

... More
16.77 : Scarifying the existing bituminous road surface to a depth of 50 mm and disposal of scarified material within all lifts and lead upto 1 km ( by mechanical means).

24389.64

-

-

... More
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

387.89

-

-

... More
2.31 : Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared

5159.66

-

-

... More
13.99.1 : Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One or more coats on old work

1768.82

-

-

... More
Road shoulder - Plot A, Plot F and Plot C

-

-

-

... More
2.9.1 : Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock

907.43

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

290.39

-

-

... More
4.3.1 : Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns

3629.71

-

-

... More
4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

435.57

-

-

... More
Augmentation of Fire Fighting systems-Implementation of common fire fighting system in Plot-F

-

-

-

... More
16.7.3.2 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.NON- RETURN VALVE with duel plate of C I body SS plated vulcanized NBR Seal flanged end & PN 16 pressure rating for chilled/ hot water circulation including insulation as specified.NON- RETURN VALVE of 150 mm dia

1

-

-

... More
16.7.3.3 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.NON- RETURN VALVE with duel plate of C I body SS plated vulcanized NBR Seal flanged end & PN 16 pressure rating for chilled/ hot water circulation including insulation as specified.NON- RETURN VALVE of 125 mm dia

1

-

-

... More
16.7.3.4 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.NON- RETURN VALVE with duel plate of C I body SS plated vulcanized NBR Seal flanged end & PN 16 pressure rating for chilled/ hot water circulation including insulation as specified.NON- RETURN VALVE 100 mm dia

2

-

-

... More
16.7.3.6 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.NON- RETURN VALVE with duel plate of C I body SS plated vulcanized NBR Seal flanged end & PN 16 pressure rating for chilled/ hot water circulation including insulation as specified.NON- RETURN VALVE of 65 mm dia

2

-

-

... More
16.7.4.2 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.Y- Strainer of Ductile CI Body flanged ends with stainless steel strainer for chilled/hot water circulation including insulation as specifiedY- Strainer of 150 mm dia

1

-

-

... More
16.7.4.3 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.Y- Strainer of Ductile CI Body flanged ends with stainless steel strainer for chilled/hot water circulation including insulation as specifiedY- Strainer of 125 mm dia

2

-

-

... More
16.7.4.6 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.Y- Strainer of Ductile CI Body flanged ends with stainless steel strainer for chilled/hot water circulation including insulation as specifiedY- Strainer of 65 mm dia

2

-

-

... More
od74698/2024_2025 : Fabrication, supply, Installation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required : Incomings 630A, 50kA 4 Pole MCCB, Ics=100% Icu Rating Digital Voltmeter 0-500V with selector switch Ammeter (0-630 A) with selector swtich & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 800Amps Outgoings (Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps) Main Fire Pump 200 Amp, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 75 hp pump with overload protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. - 2 sets Jockey Pump 100 Amp, 50kA TPN MCCB, Ics=100% Icu, with Suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. - 2 sets Diesel Engine Control Control for diesel engine comprising - Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indicationBattery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0- 20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification

1

-

-

... More
od67880/2024_2025 : Supplying, installation, testing and commissioning of diesel engine driven main fire pump<br>suitable for automatic operation and consisting of following, complete in all respects, as<br>required : (Diesel Driven Pump)<br>Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with<br>stainless steel shaft, mechanical seal to ensure a minimum pressure of 3.5 kg/sq.cm. at highest and farthest outlet at specified flow of 2850 lpm at 70 m. head conforming to IS 1520.Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant BS&IS<br>standard complete with auto starting mechanism, 12 /24 volts electric starting equipment,<br>diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm<br>thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer,<br>instruments and protection as per standard specification, stop solenoid for auto stop in the<br>event of fault with audio indications, painted with post office red colour etc. as required.<br>M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as<br>required.<br>Suitable cement concrete foundation duly plastered and with anti vibration pads.

1

-

-

... More
od67886/2024_2025 : Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable<br>for automatic operation and consisting of following, complete in all respects, as required :<br>Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze<br>impeller with stainless steel shaft, mechanical seal conforming to IS 1520.<br>Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for<br>operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure,<br>horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.<br>M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as<br>required.<br>Suitable cement concrete foundation duly plastered with anti vibration pads.2850 lpm at 88 m Head

2

-

-

... More
od67974/2024_2025 : Supplying, installation, testing and commissioning of electric driven pressurisation pump<br>suitable for automatic operation and consisting of following, complete in all respects, as<br>required : (Jockey Pump)<br>Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with<br>stainless steel shaft, mechanical seal conforming to IS : 1520.<br>Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3<br>phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot<br>mounted type with Class-'F' insulation, conforming to IS : 325.<br>M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as<br>required.<br>Suitable cement concrete foundation duly plastered and with anti vibration pads.300lpm@88m head

2

-

-

... More
od68080/2024_2025 : Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS<br>1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground<br>including welding, excavation & providing cement concrete blocks as supports, anticorrosive<br>treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes<br>complete as required-100 mm

226

-

-

... More
od72745/2024_2025 : Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS<br>1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground<br>including welding, excavation & providing cement concrete blocks as supports, anticorrosive<br>treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes<br>complete as required:150 mm dia

570

-

-

... More
od68081/2024_2025 : Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS<br>1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground<br>including welding, excavation & providing cement concrete blocks as supports, anticorrosive<br>treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes<br>complete as required-200 mm dia

373

-

-

... More
od68222/2024_2025 : Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS<br>3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets<br>etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with<br>two or more coats of synthetic enamel paint of required shade complete as required : 250mm

4

-

-

... More
od68223/2024_2025 : Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS<br>3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets<br>etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with<br>two or more coats of synthetic enamel paint of required shade complete as required :200 mm

20

-

-

... More
od68224/2024_2025 : Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS<br>3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets<br>etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with<br>two or more coats of synthetic enamel paint of required shade complete as required-150 mm

12

-

-

... More
od68225/2024_2025 : Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS<br>3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets<br>etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with<br>two or more coats of synthetic enamel paint of required shade complete as required:125 mm

7

-

-

... More
od68226/2024_2025 : Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS<br>3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets<br>etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with<br>two or more coats of synthetic enamel paint of required shade complete as required :100 mm

44

-

-

... More
od68227/2024_2025 : Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS<br>3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets<br>etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with<br>two or more coats of synthetic enamel paint of required shade complete as required :65 mm

4

-

-

... More
od68228/2024_2025 : Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS<br>3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets<br>etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with<br>two or more coats of synthetic enamel paint of required shade complete as required :50 mm

4

-

-

... More
od68229/2024_2025 : Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS<br>3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets<br>etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with<br>two or more coats of synthetic enamel paint of required shade complete as required :25mm

25

-

-

... More
od71450/2024_2025 : Providing, fixing, testing and commissioning of Forged Ball Valve, PN-16 or above gunmetal /cast alloy, SS handle including necessary accessories and connections.25 mm

6

-

-

... More
od70442/2024_2025 : Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6<br>with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts,<br>washers, gaskets and conforming to IS 780 of following sizes as required :50 mm

2

-

-

... More
od70443/2024_2025 : Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6<br>with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts,<br>washers, gaskets and conforming to IS 780 of following sizes as required :65 mm

2

-

-

... More
od70441/2024_2025 : Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6<br>with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts,<br>washers, gaskets and conforming to IS 780 of following sizes as required :100 mm

20

-

-

... More
od70423/2024_2025 : Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6<br>with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts,<br>washers, gaskets and conforming to IS 780 of following sizes as required :125 mm

3

-

-

... More
od70424/2024_2025 : Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6<br>with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts,<br>washers, gaskets and conforming to IS 780 of following sizes as required :150 mm

2

-

-

... More
od70425/2024_2025 : Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6<br>with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts,<br>washers, gaskets and conforming to IS 780 of following sizes as required :200 mm

2

-

-

... More
od70772/2024_2025 : Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia<br>instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked,<br>conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required<br>:single headed stainless steel

17

-

-

... More
od70773/2024_2025 : Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required with testing arrangement.

1

-

-

... More
od70929/2024_2025 : Supplying, fixing, testing & commissioning of flanged single arch rubber expansion bellow with minimum operating pressure of 16 kg/cm2 of following size with all accessories - 100 mm NB

2

-

-

... More
od70930/2024_2025 : Supplying, fixing, testing & commissioning of flanged single arch rubber expansion bellow with minimum operating pressure of 16 kg/cm2 of following size with all accessories - 125mm NB

3

-

-

... More
od70931/2024_2025 : Supplying, fixing, testing & commissioning of flanged single arch rubber expansion bellow with minimum operating pressure of 16 kg/cm2 of following size with all accessories - 150 mm NB

1

-

-

... More
od71020/2024_2025 : Supplying, fixing, testing & commissioning of double flanged water meter-4" dia cast iron ISI marked complete with nuts, bolts, washers, gaskets as required.

17

-

-

... More
od71433/2024_2025 : Supplying, fixing, testing & commissioning of 25mm Air release valve as per IS:14845 ISI Marked, with forged brass ball valve etc with all accessories

2

-

-

... More
od74664/2024_2025 : Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.

5

-

-

... More
od74665/2024_2025 : Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female<br>couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Stainless Steel (Grade 304)

34

-

-

... More
od74666/2024_2025 : Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal<br>diameter size nozzle conforming to IS 903 suitable for instantaneous connection to<br>interconnect hose pipe coupling as required :Stainless Steel (Grade 304)

17

-

-

... More
od74810/2024_2025 : Supply installation of surge arrestor Type 1+2, 12.5 kVA, 3P+N configuration, Conforming to IEC 61643-11 including connections etc as directed.

1

-

-

... More
od74861/2024_2025 : Providing & fixing pressure gauges of not less than 100mm diameter dial of pressure range 0-10 kg/cm2 complete with shut off valve duly calibrated before installation

6

-

-

... More
od74931/2024_2025 : Supply and fix at site in position Fire Hose Cabinet, wall / pole mounting type, 30” x 24” x 10” size, to accommodate two 15m length of delivery hose and branch pipe, acrylic fronted double door, with lock, 2 keys and a break glass recess for keys, painted Fire Red. The price shall be inclusive of fixing accessories and as per requirement

17

-

-

... More
od74932/2024_2025 : Supplying, installation, testing & commissioning fire alarm hooter mounted in A.B.S. box etc. complete as required

1

-

-

... More
od76582/2024_2025 : Supplying and fixing of fire brigade connection of cast iron body with gun metal male<br>instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe<br>connection conforming to IS 904 as required :4 way - 150 mm dia M.S. Pipe

1

-

-

... More
1.10.2 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group B

6

-

-

... More
1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire

60

-

-

... More
1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

52

-

-

... More
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

20

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

20

-

-

... More
1.33 : Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.

2

-

-

... More
1.50.1 : Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep

1

-

-

... More
2.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door

1

-

-

... More
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

5

-

-

... More
2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

6

-

-

... More
2.12.1 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

1

-

-

... More
2.14.1 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps

1

-

-

... More
4.6.4 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.300 mm width X 50 mm depth X 1.6 mm thickness

15

-

-

... More
4.7.4 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends " ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.300 mm width X 50 mm depth X 1.6 mm thickness

2

-

-

... More
5.2 : Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required

2

-

-

... More
5.8 : Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)

20

-

-

... More
7.7.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)

10

-

-

... More
9.1.7 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 10 sq. mm (22mm)

10

-

-

... More
9.1.10 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 35 sq. mm (28mm)

8

-

-

... More
9.1.27 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)

2

-

-

... More
90.4.10 : Conveyance, installation , testing and commissioning of exhaust fans of size up to 450mm in the existing opening, fixing necessary anchor bolts / bolt and nuts etc., as required including giving connections with the supplied wire along with the exhaust fan.

1

-

-

... More
90.12.7.14 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.

32

-

-

... More
90.12.7.17 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.

70

-

-

... More
90.12.7.34 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.

30

-

-

... More
90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required

145

-

-

... More
90.16.5.3 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.

14

-

-

... More
od75589/2024_2025 : Supply of 230V, 450mm,1400rpm industrial heavy duty exhaust fan with (CG/Havells/Almonard)<br>

1

-

-

... More
od75872/2024_2025 : Supply and laying of PVC insulated PVC sheathed armoured cable with copper conductor including laying through trench, cable tray, wall of following size 1.5 sqmm 3 core PVC / XLPE insulated armoured control cables with copper conductors for working voltages up to and including 1100 V conforming to IS 1554 part I 1988 for PVC and IS 7098 Part If for XLPE

60

-

-

... More
od75873/2024_2025 : Supply and making end termination with brass compression gland and copper lugs of following size of PVC insulated and PVC sheathed/ XLPE cable with copper conductor of 1.1 kV grade as required - 3C x 1.5 sqmm

6

-

-

... More
90.12.1.14 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).

25

-

-

... More
1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch

3

-

-

... More
1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet

3

-

-

... More
1.27.2 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)

3

-

-

... More
od76066/2024_2025 : Supply, instllation of 20W led tube light, cool white, 2000 lumens, THD <5%, power factor >0.98, RoHS compliant, duly wired up for use on 230 V AC supply.

7

-

-

... More
od85823/2024_2025 : Supply installation testing commissioning of weatherproof metering cubicle for provision of 3 phase CT operated energy meter CTs etc with energy meter, CT, cut out fuse, neutral link, bus bar etc including all accessories etc

1

-

-

... More
od85824/2024_2025 : Supply installation of weatherproof metering cubicle for single phase energy meter with 32 A cutout fuse, neutral link, 0-40A, 240V energy meter etc will accessories..

1

-

-

... More
Augmentation of electrical works and implementation of streetlighting system

-

-

-

... More
11.3.1 : Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.Above 4.5 metre and upto 6.5 metre

9

-

-

... More
90.15.4.3 : Supply Conveyance, installation, testing and commissioning of 70W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)

41

-

-

... More
5.7 : Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.

260

-

-

... More
5.17 : Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.

30

-

-

... More
90.12.41.33 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.

55

-

-

... More
90.12.7.35 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.

22

-

-

... More
9.1.29 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm)

4

-

-

... More
9.4.26 : Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.31/2 X 240 sq. mm

2

-

-

... More
od77487/2024_2025 : Supply and Installation Fire Extinguisher-CO2 4.5 Kg Type including wall clamp etc.

2

-

-

... More
90.16.5.3 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.

50

-

-

... More
9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)

28

-

-

... More
9.1.34 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)

4

-

-

... More
15.4.3 : Supplying, installation, testing and commissioning of Astronomical time switch capable of following output in feeder pillars/ Lighting DBs for automatic switching On &OFF of street lights at sun set & sun ruse or twilight override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete ad required3 output (1output per phase) and suitable for three phase supply

2

-

-

... More
2.5.1 : Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required .(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)4 way (4 + 12), Double door

2

-

-

... More
2.10.5 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral

8

-

-

... More
2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

12

-

-

... More
2.13.1 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

2

-

-

... More
90.15.3.3 : Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70 mm top diameter, 130 mm bottom diameter thickness 3mm base plate dimensions of 200x200x12 mm suitable for wind speed as per IS 875 Part III single arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc. complete 6 Meters

9

-

-

... More
90.12.1.40 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).

475

-

-

... More
90.12.1.42 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).

20

-

-

... More
od74189/2024_2025 : Supply,installation,testing and commissioning of 1 run 10 square mm ABC PVC insulated and PVC sheathed /XLPE aluminium conductor cable of 1.1 kV grade with all required accessories,overhead through street light poles

770

-

-

... More
od74638/2024_2025 : Supply installation testing of outdoor whether proof feeder pillar with 4 way DB enclosure, three phase with neutral, earthing point etc for street light control , provision to accommodate automatic switching circuits, breakers etc. The feeder pillar should have additional single phase circuit breakers, Rate shall be inclusive for the concrete foundation for the feeder pillar, 50cm above ground.

1

-

-

... More
1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C

10

-

-

... More
1.11 : Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.

1

-

-

... More
1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire

134

-

-

... More
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

150

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

50

-

-

... More
1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch

4

-

-

... More
1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet

4

-

-

... More
1.26 : Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

4

-

-

... More
1.27.2 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)

4

-

-

... More
od75589/2024_2025 : Supply of 230V, 450mm,1400rpm industrial heavy duty exhaust fan with (CG/Havells/Almonard)<br>

5

-

-

... More
1.55.3 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C

16

-

-

... More
5.2 : Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required

2

-

-

... More
2.4.1 : Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4 + 12), Double door

1

-

-

... More
2.13.2 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps

1

-

-

... More
2.15.2 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

1

-

-

... More
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

12

-

-

... More
2.2.18 : Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required400 Amp, 50 KA, 4 pole

1

-

-

... More
od75304/2024_2025 : Supply of 1 pair 11 KV rubber hand gloves of approved make.<br>

1

-

-

... More
od75305/2024_2025 : Supply & fixing Laminated drawings of electrical lay out, schematic drawing etc on good frame work.<br>Supply and Installation<br>

1

-

-

... More
od75306/2024_2025 : Supply and providing laminated First Aid chart duly framed and placed in a conspicuous location for clear vision.<br>

1

-

-

... More
od75700/2024_2025 : Supply, installation , testing and commissioning metering of totally enclosed compartmentalized dust and vermin proof cubical segregated and modular in construction M.V. panel board free standing fabricated with 14swg and 14 swg of CRCA M.S. sheet, powder coated , bus-bar chamber ,outgoing switchgear etc. (all feeder unit Would be compartmentalized), color coded PVC sleeved vertical / horizontal Aluminium busbar of required size of length, (bus-bar distances shall be minimum 32 mm ) insulators, hardware, neoprene gasket , hinged door, interconnecting single core multi strand lugged copper wire having required current density ,320 Amps 4p Isolator-1no,Aluminium Busbar of 50 X 10 mm X 6 Mtrs-4nos, RYB indicators one each, V&A meter-1 No each, CT 250/5- 3 nos,15VA, CL-1 ,100A 4P MCCB with all other accessories - 8 set. The panel should have provision for installing CT operated three phase energy meter - 8 nos

1

-

-

... More
od76138/2024_2025 : Supply and installation of 20 W, 2000 lumen LED, IP 65 street light fitting with aluminium housing, stove enameled CRCA sheet steel reflector cover, acrylic cover complete with THD <10%, power factor >0.98, RoHS compliant, duly wired up for use on 230 V AC supply

19

-

-

... More
od76066/2024_2025 : Supply, instllation of 20W led tube light, cool white, 2000 lumens, THD <5%, power factor >0.98, RoHS compliant, duly wired up for use on 230 V AC supply.

47

-

-

... More
od76192/2024_2025 : Supply and installation of 6" Borewell Submersible Pump set, 22.5 kW, 15 stage, with a delivery of 58 cum/hr at 110 meter head.

2

-

-

... More
od88542/2024_2025 : Supply, Installation, Testing and Commissioning of on grid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono Crystalline silicon sola r cells, net metering facility, necessary protections, earthing, mounted on Aluminium/ GI structure of suitable strength with following components complete as required:- a) Solar Photovoltaic Module of capacity 330Wp or above, manufactured in India, conforming to IS14286/ IEC61215, IS/IEC61730-Part-1, IS/IEC61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Uni t(PCU) of 350-800 VDC Input voltage range and 400VAC, three phase, 4wire, 50Hz+/-2.5Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d) Fixing of Array junction box & Main junction box with IP65 protection and termination arrangement for incoming and outgoing cable along with lands, lugs and other accessories etc. as required. e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/ conduit lugs and other accessories etc. as required.

130

-

-

... More
od77291/2024_2025 : Supply, installation , testing and commissioning of totally enclosed compartmentalized dust and vermin proof cubical segregated and modular in construction M.V. panel board free standing fabricated with 14swg and 14 swg of CRCA M.S. sheet, powder coated , bus-bar chamber ,outgoing switchgear etc. (all feeder unit Would be compartmentalized), color coded PVC sleeved vertical / horizontal Aluminium busbar of required size of length, (bus-bar distances shall be minimum 32 mm ) insulators, hardware, neoprene gasket , hinged door, interconnecting single core multi strand lugged copper wire having required current density ,400 Amps 4p Isolator-1no at incomer ,Aluminium Busbar of 50 X 10 mm -4nos, RYB indicators one each, V&A meter-1 No each, CT 400/5- 3 nos 15VA CL-1 , outgoing 315Amps 4P isolator, 250 A 4 pole MCCB – 2 nos etc with all accessories.

1

-

-

... More
Augmentation of Fire Fighting systems-Fire fighting and fire alarm system in SDF building

-

-

-

... More
od70772/2024_2025 : Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia<br>instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked,<br>conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required<br>:single headed stainless steel

8

-

-

... More
od68223/2024_2025 : Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS<br>3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets<br>etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with<br>two or more coats of synthetic enamel paint of required shade complete as required :200 mm

30

-

-

... More
od68224/2024_2025 : Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS<br>3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets<br>etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with<br>two or more coats of synthetic enamel paint of required shade complete as required-150 mm

50

-

-

... More
od68226/2024_2025 : Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS<br>3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets<br>etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with<br>two or more coats of synthetic enamel paint of required shade complete as required :100 mm

22

-

-

... More
od76582/2024_2025 : Supplying and fixing of fire brigade connection of cast iron body with gun metal male<br>instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe<br>connection conforming to IS 904 as required :4 way - 150 mm dia M.S. Pipe

1

-

-

... More
od68228/2024_2025 : Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS<br>3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets<br>etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with<br>two or more coats of synthetic enamel paint of required shade complete as required :50 mm

50

-

-

... More
od70441/2024_2025 : Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6<br>with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts,<br>washers, gaskets and conforming to IS 780 of following sizes as required :100 mm

1

-

-

... More
od70424/2024_2025 : Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6<br>with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts,<br>washers, gaskets and conforming to IS 780 of following sizes as required :150 mm

1

-

-

... More
od74931/2024_2025 : Supply and fix at site in position Fire Hose Cabinet, wall / pole mounting type, 30” x 24” x 10” size, to accommodate two 15m length of delivery hose and branch pipe, acrylic fronted double door, with lock, 2 keys and a break glass recess for keys, painted Fire Red. The price shall be inclusive of fixing accessories and as per requirement

8

-

-

... More
16.7.3.2 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.NON- RETURN VALVE with duel plate of C I body SS plated vulcanized NBR Seal flanged end & PN 16 pressure rating for chilled/ hot water circulation including insulation as specified.NON- RETURN VALVE of 150 mm dia

1

-

-

... More
od74932/2024_2025 : Supplying, installation, testing & commissioning fire alarm hooter mounted in A.B.S. box etc. complete as required

8

-

-

... More
od74665/2024_2025 : Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female<br>couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Stainless Steel (Grade 304)

16

-

-

... More
od74666/2024_2025 : Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal<br>diameter size nozzle conforming to IS 903 suitable for instantaneous connection to<br>interconnect hose pipe coupling as required :Stainless Steel (Grade 304)

8

-

-

... More
od77470/2024_2025 : "SITC of Ravel 12 Zone Fire Alarm Control panel, with Touch keypad, 20 X 4 Character LCD Display, Inbuild RS-485 Communication card can connect Max. 16 panels in a single network communication, Peer to Peer network through RS-485 communication Approval: CE Mark. with,<br>1) Provision to connect zone wise sounder (RE-90ZS) in a separate cabinet.<br>2) Provision to connect zone wise relay (RE- 90ZC) in a separate Cabinet<br>3) MODBUS Converter (RE-90MB)<br>4) TCP/IP Module (RE-TCP)<br>5) SOFT CONNECT software for PC Monitoring<br>6) Repeater Panel compatible with RE-900 RP Series for monitoring main panels.<br>7) provision to connect & integrate Conventional Public Adress system through RS-485 Communication (REVAC)."<br>and all necessary accessories

1

-

-

... More
od77553/2024_2025 : Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with<br>annealed copper conductor having XLPE insulation, steel wire armouring & FRLS<br>outer sheath complete as required.

200

-

-

... More
od77554/2024_2025 : Supplying, installation, testing & commissioning of smoke detector with builtin LED<br>and mounting base complete with all connections etc. as required.<br>COST FOR 1 POINT

20

-

-

... More
od77558/2024_2025 : Supplying, installation, testing & commissioning of manual call box of ABS type in<br>surface/recess with stainless steel chain & hammer assembly complete with glass<br>and push button etc. as required.<br>COST FOR 1 POINT

3

-

-

... More
od77598/2024_2025 : Supplying and installing of in position the following type of sign boards made out of 3mm thick "Opaque"<br>PVC foam board with computer cut, PVC Non-reflective self-adhesive vinyl painted foam board,<br>complete with mirror fasteners. Size: 60cm x 15cm -Photo luminous type

18

-

-

... More
od77642/2024_2025 : Supply and fixing of 1 x 6W, 240 V, 1 ph, 50 Hz indoor type emergency exit light fixture with 1.3 AH 4hrs<br>battery back-up unit, LED Lamps, indicating Fire Exit, recess mounted type. 24hrs x 7days working conditional.

9

-

-

... More
Augmentation of proper water supply

-

-

-

... More
16.7.3.1 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.NON- RETURN VALVE with duel plate of C I body SS plated vulcanized NBR Seal flanged end & PN 16 pressure rating for chilled/ hot water circulation including insulation as specified.NON- RETURN VALVE of 200 mm dia

4

-

-

... More
od70425/2024_2025 : Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6<br>with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts,<br>washers, gaskets and conforming to IS 780 of following sizes as required :200 mm

4

-

-

... More
od79821/2024_2025 : Supply installation testing and commissioning of 3 stage pump with Bronze impeller, SS Shaft , Gland packed Horizontal Multi stage type pump coupled to 30 kW/40 hp, 2950 RPM TEFC squirrel Cage induction motor on a common base frame with coupling and coupling guard suitable for 50 m3/hr @ 120 mtr head - Kirlosker RKB-65/19E / Eq.

2

-

-

... More
Other Civil works - New Pump Room Plot F (Fire)

-

-

-

... More
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

569.75

-

-

... More
2.16.3 : Close timbering in trenches including strutting, shoring and packing cavities (wherever required) complete (Measurements to be taken of the face area timbered).Depth exceeding 3 m but not exceeding 4.5 m

215

-

-

... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

178.77

-

-

... More
2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil

247.25

-

-

... More
2.28.1 : Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.All kinds of soil

215

-

-

... More
2.33.1 : Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyound 30 cm girth up to and including 60 cm girth

5

-

-

... More
2.33.2 : Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyound 60 cm girth up to and including 120 cm girth

5

-

-

... More
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

391.52

-

-

... More
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

266.01

-

-

... More
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

44.59

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

27168.31

-

-

... More
5.33.1 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level

189.53

-

-

... More
5.34.1 : Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).

189.53

-

-

... More
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

585.28

-

-

... More
13.21 : Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.

100

-

-

... More
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer

298.51

-

-

... More
13.82.2 : Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture including applying additional coats wherever required, to achieve even shade and colour.Two coats

298.51

-

-

... More
13.88 : Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete

298.51

-

-

... More
13.111.2 : Finishing walls with Acrylic Smooth exterior paint of required shade :Old work (One or more coat applied @ 0.90 ltr/10 sqm).

69.28

-

-

... More
22.26 : Providing and applying of swellable type water stop tape, 19mm x 25mm thick in linear meter (expansive nature) for construction joints treatment of RCC structure such as raft slab, retaining walls, water storage tank and at the junctions of raft slab with the retaining walls etc.. After cleaning the surface, one coat of required primer for swellable water stop tape shall be applied throughout the length of the joint @3.78 litre per 240 running meter. Over the primed surface swellable type water stop tape shall be placed. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.

55

-

-

... More
19.16 : Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS: 10910 on 12 mm dia steeel bar conforming to IS:1786, having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 ( 1cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) Complete as per design

20

-

-

... More
6.4.2 : Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in:Cement mortar 1:6 (1 cement : 6 coarse sand)

14.02

-

-

... More
13.40 : Distempering with dry distemper of approved brand and manufacture (two or more coats) of required shade on new work, over and including water thinnable priming coat to give an even shade:

147.38

-

-

... More
13.46.1 : Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

252.07

-

-

... More
9.48.1 : Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding

57.6

-

-

... More
od85865/2024_2025 : Supply, Installation of GI puddle flanges of following size 200 mm Dia during RCC work

1

-

-

... More
od85866/2024_2025 : Supply, Installation of GI puddle flanges of following size 150 mm Dia during RCC work with all required accessories

1

-

-

... More
od85867/2024_2025 : Supply, Installation of GI puddle flanges of following size 125 mm Dia during RCC work with all required accessories

2

-

-

... More
od85868/2024_2025 : Supply, Installation of GI puddle flanges of following size 100 mm Dia during RCC work with all required accessories

1

-

-

... More
od85869/2024_2025 : Supply, Installation of GI puddle flanges of following size 65mm Dia during RCC work with all required accessories

2

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

21.31

-

-

... More
10.6.2 : Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.20 mm M.S. laths with 1.20 mm thick top cover

8.4

-

-

... More
10.7 : Providing and fixing ball bearing for rolling shutters.

4

-

-

... More
10.26.2 : Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.E.R.W. tubes

30

-

-

... More
50.9.1.1 : Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood

0.17

-

-

... More
50.9.3.1 : Providing and fixing paneled or paneled and glazed shutters for doors, windows and clerestory windows, 30 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding paneling which will be paid for separately, all complete as per direction 0f Engineer in- charge. using Anjili/ Jack wood

4.32

-

-

... More
50.9.6.1 : Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. Using Anjili wood / jack wood 30 mm thick shutters

4.32

-

-

... More
od91443/2024_2025 : "600 X 600 mm (24"" X 24"") inside using self pigmented type double seal (Air & Water tight) FRP<br>manhole cover and frame Light Duty (5 MT) with closed bottom (not thru & thru) lifting key holes & load<br>tested as per IS:1726 & BS EN:124.<br>For OH Water tank"<br>

4

-

-

... More
od91624/2024_2025 : 9 mm cement plaster of mix :<br>1:4 (1 cement: 4 coarse sand)

131.8

-

-

... More
13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work

21.12

-

-

... More
Painting of various buildings-SDF

-

-

-

... More
13.50.3 : Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron /steel works

2910.97

-

-

... More
13.52.1 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work

2910.97

-

-

... More
13.111.1 : Finishing walls with Acrylic Smooth exterior paint of required shade :Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface

6926.92

-

-

... More
21.1.1.2 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)

61.4

-

-

... More
21.1.2.2 : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)

13.29

-

-

... More
21.2.2 : Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides

7.02

-

-

... More
21.13 : Providing and fixing 100 mm brass locks ( best make of approved quality ) for aluminium doors including necessary cutting and making good etc. complete

4

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.