Kerala Industrial Infrastructure Development Corporation Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kerala Industrial Infrastructure Development Corporation - KINFRA Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date13 Nov 2023
Closing Date29 Nov 2023
Tender Amount₹ 1,24,93,240 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material. Beyound 60 cm girth up to and including 120 cm girth

2

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil

110.57

-

-

... More
 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5m in width as well as 10 sqm on plan including disposal of excavated earth up to 50 m and lift up to 1.5 m, disposed soil to be levelled and neatly dressed:All Kinds of soil

1226.59

-

-

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

18.26

-

-

... More
 Making plinth protection 50 mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed of dry stone aggregate 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.

252

-

-

... More
 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:3 (1 cement : 3 coarse sand)

15.87

-

-

... More
 Brick work with common burnt clay machine moulded perforated bricks of classdesignation 12.5 conforming to IS: 2222 in superstructure above plinth level up tofloor five level in cement mortar 1:6 (1 cement : 6 coarse sand):With F.P.S. ( non modular ) bricks

13.01

-

-

... More
 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm

198.32

-

-

... More
 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.

87.96

-

-

... More
 Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm

10.61

-

-

... More
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.

103.68

-

-

... More
 Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.

113.46

-

-

... More
Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.

11.35

-

-

... More
 Laying old cement concrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (Old CC paver blocks shall be supplied by the department free of cost.)

113.64

-

-

... More
 Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar

12.49

-

-

... More
 15 mm cement plaster on the rough side of single or half brick wall of mix:1:4 (1 cement :4 fine sand)

36.49

-

-

... More
 12 mm cement plaster finished with a floating coat of neat cement of mix:1:4 ( 1 cement : 4 fine sand)

178.03

-

-

... More
 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.

17877.67

-

-

... More
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer

10732.18

-

-

... More
Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces:One coat

7145.49

-

-

... More
 Finishing walls with Acrylic Smooth exterior paint of required shade :Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface

7145.49

-

-

... More
 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.One coat

3830.07

-

-

... More
 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats

9719.12

-

-

... More
 Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Old work (one or more coats)

370.96

-

-

... More
 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work

1332.99

-

-

... More
 Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C. kitchen and the like consisting of : i) I course of applying cement slurry @ 4.4 Kg/ sqm mixed with water proofing compound conforming to IS: 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. ii) II course of 20 mm cement plaster 1:3 ( 1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. iii) III course of applying blown or residual bitumen applied hot at 1.7 kg per sqm of area. iv) IV course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/ sqm.

14.38

-

-

... More
 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.

106.23

-

-

... More
Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge.

26.8

-

-

... More
Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge.

92.38

-

-

... More
Providing and fixing paneled or paneled and glazed shutters for doors, windows and clerestory windows, 30 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding paneling which will be paid for separately, all complete as per direction 0f Engineer in- charge. using Anjili/ Jack wood

11.5

-

-

... More
 Cleaning of under ground sump, Over Head R.C.C. Tank ( independent staging) including disposal of slit and rubbish, all as per direction of Engineer-in-Charge. The cleaning shall consist following operations:- (i)Tank shall be emptied of water by pumping & bottom shall be cleaned of slit and other deposits. (ii) Entire surface area of the sump shall then scrubbed thoroughly with wire brush etc. and pressure washed with water. (iii) Chlorination of RCC internal surface by liquid chlorine.(iv) The treated surface shall be dried using air jetting and all loose particles shall be removal from the surface. (v) Finally the surface shall be treated with ultraviolet radiation etc. as per direction of Engineer-in-Charge.

625.29

-

-

... More
 Cleaning of chocked sewer line by diesel running vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having 4000 litres suction capacity and 6000 litres water jetting tank capacity including skilled operator, supervising engineer etc. for cleaning and partial desilting of manholes and dechocking of sewer lines. Dechocking and flushing of sewer line from one manhole to another by high pressure jetting system of 2200 PSI for sewer line from 150mm dia upto 300mm dia for all depth.

100

-

-

... More
 Cleaning and desilting of gully trap chamber, including removal of rubbish mixed with earth etc. and disposal of same, all as per the direction of Engineer-in-charge.

5

-

-

... More
 Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:11/2:3 (1 cement : 11/2 coarse sand :3 graded stone aggregate 20 mm nominal size)

5.36

-

-

... More
 Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).

3.42

-

-

... More
 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

44.95

-

-

... More
 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more

550

-

-

... More
 Providing and fixing C.P brass bib cock of approved quality conforming to IS: 8931.15 mm nominal bore

10

-

-

... More
 Painting (one or more coats) on rain water, soil waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work :150 mm diameter pipes

70

-

-

... More
 Painting (one or more coats) on rain water, soil waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work :75 mm diameter pipes

40

-

-

... More
 Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2

50

-

-

... More
 Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching in hard rock-blasting prohibited, refilling with available earth within a lead of 50 m & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2

68

-

-

... More
 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid

12

-

-

... More
 Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in-Charge

12

-

-

... More
 Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to IS: 14616 and TADS 15:2001 (Part B), including ISI marked M.S.pressed butt hinges bright finished of required size with necessery screws, all complete as per directions of Engineer-in-Charge and panelling with panels of:12 mm thick pre- laminated particle board (decorative lamination on both sides) grade -1, medium density flat pressed, three layer particle board FPT - I or graded wood particle board FPT - I, conforming to IS : 3087, bonded with BWP type synthetic resin adhesive as per IS : 848 and prelaminated conforming to IS : 12823, Grade I, Type - II marked :

8.7

-

-

... More
 Providing and fixing bright finished brass butt hinges with necessary screws etc. complete:100x85x5.5 mm (heavy type)

75

-

-

... More
Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.

27

-

-

... More
Demolishing of bedding, dry brick bat coba up to desired depth in floors including cleaning, transportation of all debris from the toilet, stacking serviceable material, refilling and disposal of unserviceable material with in 50 metes lead from the GF of building.

23.62

-

-

... More
 Removing and re fixing existing hand rail in the ramp as per the direction of engineer i/c.M.S. tube

190.34

-

-

... More
Repairing of existing rolling shutters , to smooth operational condition excluding painting and fixing of unrepairable ball bearing for rolling shutters.

79.5

-

-

... More
 Providing and fixing ball bearing for rolling shutters.

10

-

-

... More
Removing and re fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of existing pipes, fixing of new specials if necessary with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia - External work- Exposed on wall

64

-

-

... More
Removing and re fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of existing pipes, fixing of new specials if necessary with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 - External work- Exposed on wall

80

-

-

... More
 Removing and re fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of existing pipes, fixing of new specials if necessary with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 6 Kgf/cm2 - External work - Exposed on wall

64

-

-

... More
 Removing and re fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of existing pipes, fixing of new specials if necessary with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10 Kgf/cm2 - External work- Exposed on wall

16

-

-

... More
Removing and re fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of existing pipes, fixing of new specials if necessary with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 40 mm dia 10Kgf/cm2- External work- Exposed on wall

16

-

-

... More
Removing existing M.S brackets and clamps from downtake pipes and fixing new M.S. brackets for downtake pipes as directed.

100

-

-

... More
 Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with nonwoven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25 degree, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23 degree as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150 degree. Cold flexibility shall be upto -2degree when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick

3015.44

-

-

... More
 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @0.70 kg per sqm

80.96

-

-

... More
 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm.

39.71

-

-

... More
 Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.

3

-

-

... More
 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)

12.86

-

-

... More
 Removing existing fixed GI window carefully and remove the existing glass 6mm thk from the GI frame and fixing new toughened glass in the same GI frame and fixing the same to the original position including necessary fittings and fixtures etc. complete as directed by engineer i/c.

47.4

-

-

... More
 Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect.SBR Polymer (@10% of cement weight) modified cementitious bond coat @2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer

28

-

-

... More
 Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2).50 mm average thickness in 3 layers.

70

-

-

... More
 Providing and injecting approved grout in proportion recommended by the manufacturer into cracks/honey-comb area of concrete/masonry by suitable gun/pump at required pressure including cutting of nipples after curing etc. complete as per directions of Engineer-in-Charge.br (The payment shall be made on the basis of actual weight of approved grout injected.)Stirrer mixed Acrylic Polymer of approved make @ 2% of weight of cement used) modified Cement slurry made with non shrink compound in concrete/ RCC work

20

-

-

... More
Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-In-Charge.

70

-

-

... More
 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

58.78

-

-

... More
Providing and fixing paneling or paneling and glazing in paneled or paneled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured) paneling for paneled or paneled and glazed shutters 25 mm to 40 mm thick using good quality Anjili/ Jack wood

23

-

-

... More
 Supplying and stacking of good earth at site including royalty and carriage upto 5 k.m. lead complete (earth measured in stacks will be reduced by 20% for payment).

271.76

-

-

... More
 Supplying and stacking at site dump manure from approved source, including carriage upto 5 k.m. lead complete (manure measured in stacks will be reduced by 8% for payment) :Screened through sieve of I.S. designation 20 mm

30.2

-

-

... More
Rough dressing the trenched ground including breaking clods.

1509.63

-

-

... More
Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation.

1509.63

-

-

... More
 Fine dressing of the ground

1509.63

-

-

... More
Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge

301.93

-

-

... More
 Providing and fixing Neelgiri/Mexican grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and even, watering with sprinkler

1509.63

-

-

... More
Repairing and cleaning GI pre painted windows, ventilators & louvers by providing and fixing necessary standard accessories, EDPM gaskets, handle etc.

710

-

-

... More
 Providing corrugate G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete ( up to any pitch in horizontal / vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.0.80 mm thick with zinc coating less than 275 gm/m2

112.96

-

-

... More
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

76.92

-

-

... More
 Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking the material within 50 metres lead of :Poly carbonate sheet-10mm thick.

101.52

-

-

... More
Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved

60.75

-

-

... More
 Replacing of bearing of existing motor of SKF or equivalent make for 3 phase pump motor 1 HP / 0.75 KW and servicing of the pumps (filter feed pumps) with all types of alignment of shaft etc. complete in all respect

2

-

-

... More
Servicing of Kirloskar make 1 HP / 0.75 KW Set pumps (Sewage and Sludge Pumps) including overhauling, mechanical seal, shaft sleeve, gaskets, rubber packing etc.

2

-

-

... More
 Servicing of Ingersoll Rand maake air blower with 3 phase motor 1.1 KW with F class insulation and S1 duty including changing compressor oil, V belt, Filter, strainer etc.

2

-

-

... More
Providing MBBR Media made up of PolyPropylene having surface area of 400 m2/m3 having outer diameter: approx. 22 mm height 16mm PSA/TSA Ratio 75%, Specific gravity 0.90-0.95, void ratio 0.95% and black in colour

2

-

-

... More
 SITC of Dosing pump with following specs:. Dosing rate @ 4 Kg/Cm² 1.5; 3.0; 6.0 & 10.0 LPH. Suction/Discharge tubing 4/6 mm. Frequency up to 400 spm.. Electrical 230 V AC, 50 Hz.. Frequency up to 400 spm.. PTFE diaphragm. Power consumption at 400 spm 30 W.. Splash-proof enclosure. Double ball NRV with PTFE seals. Suction tubing: 4/6mm LDPE tubing 3m long

1

-

-

... More
Removing the existing sand from Pressure Sand Filter and filling with new quartz sand ranging from 2mm to 8mm

40

-

-

... More
 Removing the existing carbon from Pressure vessel Filter and filling with new activated coconut shell carbon filter having internal surface area of 800 m2/g with 99% purity having density 550 kg/m3 and Moisture less than 5%Hardness 95% etc. complete.

25

-

-

... More
 Supplying non ioninc alum aquas solution

120

-

-

... More
 Providing Hypochlorite solution

120

-

-

... More
 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch

10

-

-

... More
 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.2 way 5/6 amps switch

10

-

-

... More
 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch

10

-

-

... More
 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet

10

-

-

... More
 Servicing of Hydropneumatic Pumps VFD operated control panelServicing of existing HYPN pumps electrical operated VFD based control panel with following items1. Removing the existing defunct VFD and Supplying, testing and commissioning of new VFD.2. Replacement of display of control panel.3. Connecting and cable and termination4. Checking of all relay and contactors.

1

-

-

... More
 Servicing of Hydropneumatic PumpsServicing of existing HYPN pumps with replacement of bushing, bearing, rings and overhauling the pumps etc. complete.

3

-

-

... More
 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

4

-

-

... More
 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.300 mm width X 50 mm depth X 1.6 mm thickness

200

-

-

... More
 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.450 mm width X 62.5 mm depth X 2.0 mm thicknessICDDescriptionUnit

50

-

-

... More
 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends " ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.300 mm width X 50 mm depth X 1.6 mm thickness

12

-

-

... More
 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends " ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.450 mm width X 62.5 mm depth X 2.0 mm thickness

12

-

-

... More
 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.300 mm width X 50 mm depth X 1.6 mm thickness

2

-

-

... More
 Service Charges and testing for 11 KV HT Panel with 1 No. of 630 A VCB and 630A LBS 7 Nos. Spare LBS with following steps:Visual Inspection: Drive insulators and molded pole unit support to be checked visually for dirt and crackingVacuum Interrupter Integrity Test: This one-minute ac high potential test to check the insulation integrity from the main circuit to ground, from the control circuit to ground, and between main circuit terminalsMechanism Check: Mechanism for any loose parts such as rings, bolts, and others etc.Insulation: cleaning of all the insulation surfaces with soft clothLubrication: light machine oil to be used for lubrication of VCBProperly clean the vacuum circuit breaker with a CRC - 226 i.e. an electrical contact cleaner. This will ensure that the lubrication is proper in the VCB.Clear any old grease in the VCB. Grease the VCB again, with new grease, of a similar typeCheck the conditions of the fixed and the floating contactsInspect the positioning of the contactsCheck the outer layer, and other hardware parts of the VCB, and see that they are fixed properlyUse the VCB’s push button to check the breaker trippingCheck the electrical current between phase and phase i.e. VCB closed stateCheck the electrical current between phase and earth i.e. VCB closed stateCheck the electrical current between phase and earth i.e. VCB open state

1

-

-

... More
Supply and Topping up of transformer oil as per IS: 335:1993 (Reaffirmed 2005) in 250Kva oil type transformer

125

-

-

... More
 Service Charges for 11 KV / 433V 250 KVA transformer oil filtering and Break Down Voltage testing and issuing of test report with following tests to be done including removing the rusting and repainting the same1. Winding Temperature2. Ambient Temperature3. OIl Temperature4. Load in amps5. Voltage6. Oil level in the transformer7. Oil level in the bushing8. Oil level in the OLTC Conservator9. Oil filled condenser bushing10. Gasket joints(may need to be tightened to avoid uneven pressure)11. Cable boxes12. Relays alarm and other circuits13. Painting14. Earth resistance

5

-

-

... More
 Service charges for main power panel EB & DG incomer 400A MCCB, 250A MCCB 2 Nos. 100A MCCB 3 Nos.a) Visually inspect primary controls for detoriation and overheatingb) Clean thoroughly, using Air Blower and visually inspect exterior and inetrior low voltage switchboards, circuit breakers, inlets, panel boards, electric distribution systems for wear and tearc) Check locking devicesd) Check all indicators, lamps, sensors, and warning lights are functioning correctlye) Check all malfunctions like loose connections, shortcircuitsf) Inpect timers, power supply units, fuse carriers, relays and control wiring for humidity or temperature damage as well as regular wear

1

-

-

... More
 Service Charges for main switch board I and IIa) Visually inspect primary controls for detoriation and overheatingb) Clean thoroughly, using Air Blower and visually inspect exterior and inetrior low voltage switchboards, circuit breakers, inlets, panel boards, electric distribution systems for wear and tearc) Check locking devicesd) Check all indicators, lamps, sensors, and warning lights are functioning correctlye) Check all malfunctions like loose connections, shortcircuitsf) Inpect timers, power supply units, fuse carriers, relays and control wiring for humidity or temperature damage as well as regular wear

2

-

-

... More
 Service charges for metering panel incomer 400A, Outgoing 125A MCCB ATSa) Visually inspect primary controls for detoriation and overheatingb) Clean thoroughly, using Air Blower and visually inspect exterior and inetrior low voltage switchboards, circuit breakers, inlets, panel boards, electric distribution systems for wear and tearc) Check locking devicesd) Check all indicators, lamps, sensors, and warning lights are functioning correctlye) Check all malfunctions like loose connections, shortcircuitsf) Inpect timers, power supply units, fuse carriers, relays and control wiring for humidity or temperature damage as well as regular wear

4

-

-

... More
 Service charges for Lift Panela) Visually inspect primary controls for detoriation and overheatingb) Clean thoroughly, using Air Blower and visually inspect exterior and inetrior low voltage switchboards, circuit breakers, inlets, panel boards, electric distribution systems for wear and tearc) Check locking devicesd) Check all indicators, lamps, sensors, and warning lights are functioning correctlye) Check all malfunctions like loose connections, shortcircuitsf) Inpect timers, power supply units, fuse carriers, relays and control wiring for humidity or temperature damage as well as regular wear

1

-

-

... More
 Service charges for APFC Panel 80kVARa) Visually inspect primary controls for detoriation and overheatingb) Clean thoroughly, using Air Blower and visually inspect exterior and inetrior low voltage switchboards, circuit breakers, inlets, panel boards, electric distribution systems for wear and tearc) Check locking devicesd) Check all indicators, lamps, sensors, and warning lights are functioning correctlye) Check all malfunctions like loose connections, shortcircuitsf) Inpect timers, power supply units, fuse carriers, relays and control wiring for humidity or temperature damage as well as regular wear

1

-

-

... More
 Service charges for pump panel consisting of incomer 125A and Outgoing 100A MCCBa) Visually inspect primary controls for detoriation and overheatingb) Clean thoroughly, using Air Blower and visually inspect exterior and inetrior low voltage switchboards, circuit breakers, inlets, panel boards, electric distribution systems for wear and tearc) Check locking devicesd) Check all indicators, lamps, sensors, and warning lights are functioning correctlye) Check all malfunctions like loose connections, shortcircuitsf) Inpect timers, power supply units, fuse carriers, relays and control wiring for humidity or temperature damage as well as regular wear

1

-

-

... More
 Supplying and erecting metal work in CRCA sheet with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete, including removing and refixing of the existing 125A MCCB in the new fabricated enclosure with all cable termination etc complete

1

-

-

... More
Supplying and fixing PVC synthetic elastomer electrically insulating mat with class C insulation conforming to IS: 15652 – 2006 & CPRI tested having 3mm thickness upto 11 kV

30

-

-

... More
 Removing the existing and replacing the new solar street light battery. buyback and installing new 3S 12V, 75Ah lithium ion battery with PVC battery casing, double insulated cell, High Charge-Discharge current up to 1C and with following features:Voltage Monitoring and control.Current monitoring and control.Short circuit protection.Overcharging current protectionOver discharging current ProtectionIndividual Cell/ String Voltage monitoring and control.Active Cell Balancing.Loose/ broken wire protectionOver charging – Discharging Protection.

64

-

-

... More
Supplying & erecting LED 20W tube light fitting (4 feet) with aluminum housing, heat sink, integrated HF electronic driver complete.

65

-

-

... More
Supplying and erecting Mirror light fitting (2 feet) including 10W LED lamp, comprises of extruded channel in plastic silver grey colour & with same plastic end cap on provided PVC block / wooden board.

20

-

-

... More
Supply and Installation of 12W, 6000k round LED lights suitable for wall/ceiling light slim panel LED Downlighter.

10

-

-

... More
Supplying and erecting LED Street light fitting suitable for 45W lamp, including lamp, with PF 0.95 class IP 66 and above housing of pressure die cast aluminum alloy and heat sink extruded aluminum complete

10

-

-

... More
 Supply of 50 sqmm 3.5 core PVC/XLPE insulated armoured cable with aluminiumconductors for working voltages up to and including 1100 voltsconforming IS 1584/part I/1988 for PVC IS 7098 part I for XLPE

350

-

-

... More
 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 35 sq. mm and upto 95 sq. mm

200

-

-

... More
 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 35 sq. mm and upto 95 sq. mm

100

-

-

... More
 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

50

-

-

... More
 Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.

10

-

-

... More
 Supply of 450mm Sweep,900 RPM Heavy Duty Exhaust Fan

10

-

-

... More
 Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep

10

-

-

... More
 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)

4

-

-

... More
 Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.31/2 X 50 sq. mm

2

-

-

... More
 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire

150

-

-

... More
 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

150

-

-

... More
 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.Group A

20

-

-

... More
 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

75

-

-

... More
 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

75

-

-

... More
 Supply and Installation of Selector Switches

5

-

-

... More
 Supply and Installation of 0-500V Voltmeter

5

-

-

... More
 Supply and Installation of 100/5A Ammeter

5

-

-

... More
 Supply and Installation of RYB Indicators

10

-

-

... More
 Supply and Installation of IP 66 100W, Luminaire with precise flood optics, for wide-angle light distribution and superior illumination light.

8

-

-

... More
 Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm

160

-

-

... More
 Supply and Installation of 60W Klite(ID 7225) Double Arm LED Driver

10

-

-

... More
 Supply and Installation of 60W Klite(ID 7225) Single Arm LED Driver

10

-

-

... More
 Supply and Installation of 60W Klite Polar Lighting Pole module including necessary fabrication work on the existing poles to fix the new lights supplied as per the direction of engineer in charge.

10

-

-

... More
 Servicing of the existing 44.3 KW / 50 HP Kirloskar make GK 80/32 B End Suction fire fighting main hydrant pump with 3 phase TEFC induction motor having 'F' class insulation, IP55 rating, S1 duty, 50 Hz and 2900 RPM , checking lubrication, bearing, bushing, gasket, alignment, coupling key, gland packing or mechanical seal, 'O' Ring adjustment of mounting pad etc. complete.

1

-

-

... More
 Servicing of the existing 5.6 KW / 7.5 HP Kirloskar make fire fighting jockey pump with 3 phase TEFC induction motor having 'F' class insulation, IP55 rating, S1 duty, 50 Hz and 2900 RPM , checking lubrication, bearing, bushing, gasket, alignment, coupling key, gland packing or mechanical seal, 'O' Ring adjustment of mounting pad etc. complete.

1

-

-

... More
 Inspection and Servicing of 50HP Diesel Pump, Supply and Installation of 12V, 200Ah Battery and Battery Charger

1

-

-

... More
 Supplying and fixing 63 mm dia, 15 m long RRL hosepipe with 63 mm dia male and female couplings dulybound with GI wire, rivets etc. conforming to IS 636(type-A) as required : Gun Metal

5

-

-

... More
 Removing old broken glass and replacing with of 2 Nos. of 4mm thick glass for Hose Boxes Size 300x450 x 2 Nos.

11

-

-

... More
 Supplying, installation, testing & commissioning of manual call box of ABS type insurface/recess with stainless steel chain & hammer assembly complete with glassand push button etc. as required

30

-

-

... More
Servicing of Butterfly valves, NRV, Strainer, Siamese Connection etc. (Total 12 Nos.) including nut bolts washer and making all valve with smooth operation etc. complete.

1

-

-

... More
Removing existing GI binding from 63mm dia Hose Pipe coupling and re-binding the same with copper wire etc. complete.

16

-

-

... More
Removing the existing foot valve and supply and installation of a new foot valve of 2.5-inch size in Jockey Pump

1

-

-

... More
Removing the existing foot valve and supply and installation of a new foot valve of 6-inch size in Main fire pump

1

-

-

... More
Supplying and erecting ABC powder type fire extinguisher as per IS : 13849 /15683 of 6 kg capacity with necessary clamp for erection on wall.

4

-

-

... More
Supplying and erecting Centrifugal water pump (Monoblock), 415 V, three phase 50 cycles A.C. supply of 3.75 KW/5 HP with discharge 5.8/8.5 Litres per second (LPS) for head of 20/36 m and 65 mm suction/ 50 mm delivery pipe on provided C.C. foundation

1

-

-

... More
 Design, Composition, Supply & Installation of Led emergency light Material: Aluminum box+PMMA board:Size: 360*200mmFeatures: Overcharge protectionLight source: 3W led lightsLight color: White ledVoltage: AC90-260V 50/60Hz, AC110V~60Hz,AC220V~50HzBattery:Ni-Cd1.2VDuration time: 90Mins or 3HoursCharging time: 24hourAutomatically Power switchFinish: Double-side side printing

1

-

-

... More
Supply and installation of 3 MM thick foam sheet with digitally printed 3M vinyl with lamination on HP Latex Printer pasted and fixing with Double sided tap of following size400 x 200mm

4

-

-

... More
Supply and Installation of 3 MM thick foam sheet with digitally printed 3M vinyl with lamination on HP Latex Printer pasted and fixing with Double sided tap of following size600 x 400mm

1

-

-

... More
Supply and Installation of 3 MM thick foam sheet with digitally printed 3M vinyl with lamination on HP Latex Printer pasted and fixing with Double sided tap of following size300 x 150mm

4

-

-

... More
 Refilling the existing 4kg ABC type fire extinguisher

12

-

-

... More
 Refilling the existing 4kg CO2 type fire extinguisher

24

-

-

... More
 Shifting of MCP & Hooter to passage area from staircase area.

8

-

-

... More
 Inspection & Servicing of Fire Alarm SystemFire Alarm Panel Addressable Loop-5 : 1 NoDetector : 100 NosM C P : 12 NosHooter : 12 Nos

1

-

-

... More
 Supplying and erecting in position Jaquar make 32mm dia concealed Flush valve CP plate etc. complete.

21

-

-

... More
 Breaking the tile and removing the existing broken Nahani trap and installing the new 100x75mm PVC Nahani trap including 110mm dia 200 to 300mm long PVC pipe hopper and making inlet connection from wash basin including making joints leakage free etc. complete in all respect

18

-

-

... More
 Removing the existing jet spray and supplying and fixing in position new Jaquar make CP Jet Spray with holder and 1m long flexible pipe etc. complete.

60

-

-

... More
Cleaning of all bathroom faucets (WC, Flush Valve, Jet Spray, Bib Cock, Wash Basin, Pillar Cock, Bottle Trap, Waste Coupling, Urinal, Push cock etc.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.